Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹53.1 CrAccepted-AOC RAM PLAZA NAVASHAKTI CHOWK BHABHA NAGAR NASHIK 422 011 | NASHIK | NASHIK | MAHARASHTRA | 422011 | ₹53.1 Cr | L1 | Accepted-AOC accept |
| 2 | L2₹103.0 CrRejected-AOC THIRD FLOOR AMIT CRYSTAL SENAPATI BAPAT ROAD PUNE 411 016 | PUNE | PUNE | MAHARASHTRA | 411016 | ₹103.0 Cr | L2 | Rejected-AOC accept |
| 3 | Rejected-Technical | - | - | Rejected-Technical REJECT |
Tender Value
₹116.0 Cr
EMD Value
₹58.0 L
Closing Date
20 Dec 2021, 6:00 pmClosed
E.E. P.W.DIVN. NANDED
OFFICE OF THE E.E. P.W.DIVN. NANDED
CONSTRUCTION OF NEW DISTRICT COURT BUILDING AT NANDED TQ. AND DIST. NANDED.
2021_PWR_744104_1
PWD/NED/61/II nd call/2021-22
Open Tender
Civil Works
720 days
NANDED
AS PER TENDER BOOKLET
4 documents required · 4 mandatory
₹5,000
₹58.0 L
16 Dec 2022
6 Dec 2021
21 Dec 2021
6 Dec 2021
20 Dec 2021
6 Dec 2021
Amount
Excavation for roadway in earth, soil of all sorts, sand, gravel or soft murum including dressing section to the required grade, camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50m. and spreading for embankment or stacking as directed. Basement Floor
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material with all lead & lifts beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means Basement Floor
Excavation for foundation in earth, soils of all types, sand,gravel and soft murum, including removing the excavated material with all lead & lifts beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5m to 3.0m) By Mechanical Means Basement Floor
Excavation for foundation in earth, soils of all types, sand,gravel and soft murum, including removing the excavated material uwith all lead & lifts beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5m to 3.0m) By Mechanical Means Basement Floor
Conveying materials obtained from road cutting including all lifts, laying in layers of 20cm to 30cm. breaking clods, dressing to the required lines, curves, grades and section, watering and compacting to not less than 97% of standard Proctor density for a lead of over 50m. to 3.00 Km. inclusive from the site of excavation to the site of deposition as directed. Basement Floor
Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and filling voids with sand compaction etc.complete. Basement Floor
Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15 cm to 20 cm thick including hand packing and compacting etc. complete. Basement Floor
Providing soling using 80 mm size trap metal in 15 cm. layer including filling voids with Crushed sand/grit, ramming, watering etc. complete. Basement Floor
Providing structural steel work in trusses, other similar trussed purlins and members with all bracing, gusset plates etc. as per detailed designs and drawings or as directed including cutting, fabricating, hoisting, erecting fixing in position, Making riveted/ bolted/ welded connection and one coat of anticorrosive paint and over it 2 coats of oil painting approved quality and shade etc. complete. Basement Floor
Providing structural steel work in trusses etc complete Terrace Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Basement Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M20 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Basement Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M15 of trap/ granite/quartzite/gneiss metal for plain or molded sills, cornice, jambs, block in course, or architraves of required size and shapes including steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided,finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Basement Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M15 etc complete Ground Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M15 etc complete First Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M15 etc complete Second Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M15 etc complete Third Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M15 etc complete Fourth Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M15 etc complete Fifth Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-15 of trap/ granite/quartzite/gneiss metal for coping to plinth or parapet, moulded or chamfered as per drawing or as directed including steel centering, plywood/ steel formwork compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.) With fine aggregate (Crushed sand VSI Grade) Terrace Floor
Providing and laying in-situ M30 Grade unreinforced plain cement concrete pavement over a prepared sub base with 43 grade cement , coarse and fine aggregate( VSI grade finely washed crushed sand) conforming to IS 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a batching and mixing plant/ non tilting mixer and Weigh batcher as per approved mix design, admixtures, transporting to site, spreading, laying with approved make paver,compacted and finished in a continuous operation, finishing to lines and grades as directed by Engineer-in-charge and curing by curing compound /by providing cement vata in cement Mortar 1:8 @0.6m X 0.6m centre to centre, admeasuring 80 mm at bottom and 40 mm at top with depth of 75mm and maintaining the same throughout curing period by any other method approved by Engineer-in- charge. Basement Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. columns as per detailed designs and drawing or as directed including Steel centering formwork, cover blocks laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Basement Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork,cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Basement Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 for R.C.C. columns etc complete Ground Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 for R.C.C. columns etc complete First Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 for R.C.C. columns etc complete Second Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 for R.C.C. columns etc complete Third Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 for R.C.C. columns etc complete Fourth Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 for R.C.C. columns etc complete Fifth Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 for R.C.C. columns etc complete Terrace Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite /quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Basement Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 for R.C.C. beam & Lintel etc complete Ground Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 for R.C.C. beam & Lintel etc complete First Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 for R.C.C. beam & Lintel etc complete Second Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 for R.C.C. beam & Lintel etc complete Third Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 for R.C.C. beam & Lintel etc complete Fourth Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 for R.C.C. beam & Lintel etc complete Fifth Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 for R.C.C. beam & Lintel etc complete Terrace Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Basement Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 for R.C.C. slab & landing etc complete Ground Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 for R.C.C. slab & landing etc complete First Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 for R.C.C. slab & landing etc complete Second Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 for R.C.C. slab & landing etc complete Third Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 for R.C.C. slab & landing etc complete Fourth Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 for R.C.C. slab & landing etc complete Fifth Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 for R.C.C. slab & landing etc complete Terrace Floor
Providing and laying Cast in situ/Ready Mixcement concrete M-30 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Ground Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 for R.C.C. chajja etc complete First Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 for R.C.C. chajja etc complete Second Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 for R.C.C. chajja etc complete Third Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 for R.C.C. chajja etc complete Fourth Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 for R.C.C. chajja etc complete Fifth Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite / quartzite / gneiss metal for R.C.C. canopy as per detailed designs and drawings including steel centering, formwork, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing etc. complete (excluding reinforcement). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) First floor
Providing and laying Cast in situ/Ready Mix cement concrete in M-30 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Basement Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 for R.C.C. Pardi etc complete Ground Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 for R.C.C. Pardi etc complete First Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 for R.C.C. Pardi etc complete Second Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 for R.C.C. Pardi etc complete Third Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 for R.C.C. Pardi etc complete Fourth Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 for R.C.C. Pardi etc complete Fifth Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 for R.C.C. Pardi etc complete Terrace Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M-30 of trap / quartzite /granite /gneiss metal for R.C.C. Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) Basement floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 for R.C.C. waist slab etc complete Ground Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 for R.C.C. waist slab etc complete First Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 for R.C.C. waist slab etc complete Second Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 for R.C.C. waist slab etc complete Third Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 for R.C.C. waist slab etc complete Fourth Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 for R.C.C. waist slab etc complete Fifth Floor
Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. Basement Floor
Providing and fixing in position TMT - FE - 500 bar reinforcement etc complete Ground Floor
Providing and fixing in position TMT - FE - 500 bar reinforcement etc complete First Floor
Providing and fixing in position TMT - FE - 500 bar reinforcement etc complete Second Floor
Providing and fixing in position TMT - FE - 500 bar reinforcement etc complete Third Floor
Providing and fixing in position TMT - FE - 500 bar reinforcement etc complete Fourth Floor
Providing and fixing in position TMT - FE - 500 bar reinforcement etc complete Fifth Floor
Providing and fixing in position TMT - FE - 500 bar reinforcement etc complete Terrace Floor
Providing expansion joints in R.C.C. framed structure (interior column) with plain premoulded filler 25 mm thick including fixing T.W. battens on both faces and finishing as directed etc. Complete. Basement Floor
Providing expansion joints in R.C.C. framed structure (interior column) Ground Floor
Providing expansion joints in R.C.C. framed structure (interior column) First Floor
Providing expansion joints in R.C.C. framed structure (interior column) Second Floor
Providing expansion joints in R.C.C. framed structure (interior column) Third Floor
Providing expansion joints in R.C.C. framed structure (interior column) Fourth Floor
Providing expansion joints in R.C.C. framed structure (interior column) Fifth Floor
Providing expansion joints in R.C.C. framed structure (exterior Columns) with plain premoulded filler 25 mm thick and 3 mm thick alluminium plate, hold fast, fixing T.W. battens on internal face, finishing etc. complete as directed. Basement Floor
Providing expansion joints in R.C.C. framed structure (exterior Columns) Ground Floor
Providing expansion joints in R.C.C. framed structure (exterior Columns) First Floor
Providing expansion joints in R.C.C. framed structure (exterior Columns) Second Floor
Providing expansion joints in R.C.C. framed structure (exterior Columns) Third Floor
Providing expansion joints in R.C.C. framed structure (exterior Columns) Fourth Floor
Providing expansion joints in R.C.C. framed structure (exterior Columns) Fifth Floor
Providing expansion joints in R.C.C. framed structure (at floor level) with premoulded filler 25 mm thick and 3 mm thick aluminium plate as required, bitumen poured filler and fixing T.W. battens on rear faces etc. complete as directed. Basement Floor
Providing expansion joints in R.C.C. framed structure (at floor level) Ground Floor
Providing expansion joints in R.C.C. framed structure (at floor level) First Floor
Providing expansion joints in R.C.C. framed structure (at floor level) Second Floor
Providing expansion joints in R.C.C. framed structure (at floor level) Third Floor
Providing expansion joints in R.C.C. framed structure (at floor level) Fourth Floor
Providing expansion joints in R.C.C. framed structure (at terrace level) with premoulded filler 25 mm thick and 3 mm thick aluminium plate as required, bituminous poured filler, fixing lead, flashing on upper side and T.W. battens on inner face finishing etc. Complete as directed. Fifth Floor
Providing fly ash brick masonry with conventional / I.S. type fly ash bricks in C.M. 1:6 in foundation and plinth including bailing out water manually striking joints, racking out joints watering and scaffolding etc. complete. Basement Floor
Providing Autoclaved Aerated Concrete Block masonary of Ecolite or equivalent make conforming to IS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in superstructure including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972) Basement Floor
Providing Autoclaved Aerated Concrete Block masonary in superstructure etc complete Ground Floor
Providing Autoclaved Aerated Concrete Block masonary in superstructure etc complete First Floor
Providing Autoclaved Aerated Concrete Block masonary in superstructure etc complete Second Floor
Providing Autoclaved Aerated Concrete Block masonary in superstructure etc complete Third Floor
Providing Autoclaved Aerated Concrete Block masonary in superstructure etc complete Fourth Floor
Providing Autoclaved Aerated Concrete Block masonary in superstructure etc complete Fifth Floor
Providing Autoclaved Aerated Concrete Block masonary in superstructure etc complete Terrace Floor
Providing Autoclaved Aerated Concrete Block masonary of Ecolite or equivalent make conforming to IS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in Half brick thick wall including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972) Ground Floor
Providing Autoclaved Aerated Concrete Block masonary in Half brick thick etc complete First Floor
Providing Autoclaved Aerated Concrete Block masonary in Half brick thick etc complete Second Floor
Providing Autoclaved Aerated Concrete Block masonary in Half brick thick etc complete Third Floor
Providing Autoclaved Aerated Concrete Block masonary in Half brick thick etc complete Fourth Floor
Providing Autoclaved Aerated Concrete Block masonary in Half brick thick etc complete Fifth Floor
Providing Second class fly ash brick masonry with conventional / I.S. type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of two bars of 6 mm diameter / two hoop iron strips 25 mm x 1.60 mm at every third course, properly bent and bounded at ends scaffolding raking out joints and watering etc. complete. Ground Floor
Providing Second class fly ash brick masonry in half brick thick etc complete First Floor
Providing Second class fly ash brick masonry in half brick thick etc complete Second Floor
Providing Second class fly ash brick masonry in half brick thick etc complete Third Floor
Providing Second class fly ash brick masonry in half brick thick etc complete Fourth Floor
Providing Second class fly ash brick masonry in half brick thick etc complete Fifth Floor
Providing & laying water proof treatment of terrace slab with B.B. Coba in all position with an average thickness of 150mm consisting specialised materials as per the manufactures specifications and covering 10 years guarantee on court fee stamp paper including all lead, lift, etc. complete. First Floor
Providing & laying water proof treatment of terrace slab with B.B. Coba etc complete Fifth Floor
Providing water proof bedding for flooring of Bath and WC 25 mm thick in C.M. 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete. Ground Floor
Providing water proof bedding for flooring of Bath and WC etc complete First Floor
Providing water proof bedding for flooring of Bath and WC etc complete Second Floor
Providing water proof bedding for flooring of Bath and WC etc complete Third Floor
Providing water proof bedding for flooring of Bath and WC etc complete Fourth Floor
Providing water proof bedding for flooring of Bath and WC etc complete Fifth Floor
Providing and applying two coats of High Albedo paint having minimum Solar Reflective Index (SRI) 108 (with solar reflectance & thermal emittance tested as per ASTM) C 1549 and ASTM C 1371 respectively, VOC less than 10 cc/gm. The coating thickness and the methodology of application shall strctly as per manufacturer's specifitions and as approved by engineer in charge. Surface preparation includes cleaning with metal wire brush to remove all dust, fungus etc, washing with water all complete.The contractor shall give guarantee for the performance of SRI and also the durabitity of coating, all complete as per direction of Engineer - in- incharge. First Floor
Providing and applying two coats of High Albedo paint etc complete Fifth Floor
Providing and fixing 20 to 25 mm thick rough shahabad box type waterproofing treatment to vertical outside faces of Reinforced Cement concrete walls of basement or underground floor including filling the gap of 25 mm between rough shahabad and R.C.C. walls with cement grout mixed with water proofing liquid Algae proof or other alike with one tile lift method, brushing the joints horizontally with cement slurry mixed with water proofing liquid for width 30 to 35 mm and sloping coping over topmost tile with cement mortar 1:3, butting the bottom most with Cement concrete 1:2:4 mixed with water proofing liquid, curing, with 7 years guarantee on court fee stamp of Rs.100/- with ponding test etc complete. (excluding Cement concrete 1:3:6 base concrete) First Floor
Providing internal cement plaster 12mm thick in single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. Basement Floor
Providing internal cement plaster 12mm thick etc omplete Ground Floor
Providing internal cement plaster 12mm thick etc omplete First Floor
Providing internal cement plaster 12mm thick etc omplete Second Floor
Providing internal cement plaster 12mm thick etc omplete Third Floor
Providing internal cement plaster 12mm thick etc omplete Fourth Floor
Providing internal cement plaster 12mm thick etc omplete Fifth Floor
Providing internal cement plaster 12mm thick etc omplete Terrace Floor
Providing cement plaster 20mm thick in Single coats in cement mortar 1:5 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete Basement Floor
Providing cement plaster 20mm thick etc complete Ground Floor
Providing cement plaster 20mm thick etc complete First Floor
Providing cement plaster 20mm thick etc complete Second Floor
Providing cement plaster 20mm thick etc complete Third Floor
Providing cement plaster 20mm thick etc complete Fourth Floor
Providing cement plaster 20mm thick etc complete Fifth Floor
Providing cement plaster 20mm thick etc complete Terrace Floor
Providing and applying plaster / wall punning with plaster of paris ( with plaster of paris material of Ambuja / Mor Chap or equivalent make ) in 10 to 13 millimeter thickness to previously plastered surface / or on newly brick surface ( Excluding rough cast plaster ) in all position including preparing and Finishing the surface scaffolding etc.complete. Basement Floor
Providing and applying plaster / wall punning with plaster of paris etc complete Ground Floor
Providing and applying plaster / wall punning with plaster of paris etc complete First Floor
Providing and applying plaster / wall punning with plaster of paris etc complete Second Floor
Providing and applying plaster / wall punning with plaster of paris etc complete Third Floor
Providing and applying plaster / wall punning with plaster of paris etc complete Fourth Floor
Providing and applying plaster / wall punning with plaster of paris etc complete Fifth Floor
Providing and applying plaster / wall punning with plaster of paris etc complete Terrace Floor
Providing and Fixing Processed Dholpur/letarite on wall surface/ plywood surface. RCC pardi/ Wall and all type of Interior, Exterior Compound wall and Gate etc. of cladding processed stone with material of Processed clay, Wooden chips, Silica sand, Cement, GFRC admixtures, Colour pigments, Fiber up to thick of 230 mm/ 25 mm including scaffolding, fixing of screw, etc. (As directed by Engineer in Charge) Basement Floor
Providing and Fixing Processed Dholpur/letarite on wall surface etc complete Ground Floor
Providing and Fixing Processed Dholpur/letarite on wall surface etc complete First Floor
Providing and fixing GRC/FRP decorative emblem with details as per drawing with the state emblem and carvings as shown in 3 dimesion upto a thickness of 150 mm with scroll designs, floral designs, dentals, flutings etc., Item to include checking all surfaces for proper line and level, scaffolding etc. complete. Item includes preparing upto 5 samples for the Architects approval. Item to include making of the clay model and mould for the decorative cornice and supply of the decorative cornice as per approved sample executed in fiber glass material Basement Floor
Providing and fixing GRC/FRP decorative emblem with details as per drawing etc complete Ground Floor
Providing and fixing GRC/FRP decorative emblem with details as per drawing etc complete First Floor
Providing and fixing GRC/FRP decorative emblem with details as per drawing etc complete Second Floor
Providing and fixing GRC/FRP decorative emblem with details as per drawing etc complete Third Floor
Providing and fixing GRC/FRP decorative emblem with details as per drawing etc complete Fourth Floor
Providing and fixing GRC/FRP decorative emblem with details as per drawing etc complete Fifth Floor
Providing and fixing GRC/FRP decorative curved festoon or garland with details as per drawing with carvings as shown in 3 dimesion upto a thickness of 150 mm with scroll designs, floral designs, dentals, flutings etc., Item to include checking all surfaces for proper line and level, scaffolding etc. complete. Item includes preparing upto 5 samples for the Architects approval. Item to include making of the clay model and mould for the decorative cornice and supply of the decorative cornice as per approved sample executed in fiber glass material Basement Floor
Providing and fixing GRC/FRP decorative curved festoon or garland with details etc complete Ground Floor
Providing and fixing GRC/FRP decorative curved festoon or garland with details etc complete First Floor
Providing and fixing GRC/FRP decorative curved festoon or garland with details etc complete Second Floor
Providing and fixing GRC/FRP decorative curved festoon or garland with details etc complete Third Floor
Providing and fixing GRC/FRP decorative curved festoon or garland with details etc complete Fourth Floor
Providing and fixing GRC/FRP decorative curved festoon or garland with details etc complete Fifth Floor
Providing and fixing GRC/FRP Medallions to be made in CNC cut GRC Jali of different sizes circular or elliptical as shown in the drawing or indicated by the Architect as mentioned below with all profiling. Item includes preparing upto 5 samples for the Architects approval. Item to include making of the clay model and mould for the decorative cornice and supply of the decorative cornice as per approved sample executed in fiber glass material Basement Floor
Providing and fixing GRC/FRP Medallions to be made in CNC cut GRC Jali of different sizes etc complete Ground Floor
Providing and fixing GRC/FRP Medallions to be made in CNC cut GRC Jali of different sizes etc complete First Floor
Providing and fixing GRC/FRP Medallions to be made in CNC cut GRC Jali of different sizes etc complete Second Floor
Providing and fixing GRC/FRP Medallions to be made in CNC cut GRC Jali of different sizes etc complete Third Floor
Providing and fixing GRC/FRP Medallions to be made in CNC cut GRC Jali of different sizes etc complete Fourth Floor
Providing and fixing GRC/FRP Medallions to be made in CNC cut GRC Jali of different sizes etc complete Fifth Floor
Providing and fixing in position factory made precast Glass fiber reinforced concrete (GRC) as per approved manufactures specification and as per approved drawings. The thickness of GRC panel should Nost be less than 20mm with minimum 20mm thick GRC pads acting as stiffeners. Colour and texture should be approved by Engineer in charge. Fixing of GRC panel on primary structure shall be done by fry cladding method with the help of SS screw fixtures, MS angle cleats, fissures plug and Dowel pin etc. in proper aligment, line and level as per the approved drawing, Finishing with GRC powder filling the joints with paintable silicon sealant neatly between GRC panel and primary structure to provide one piece look including molding and cornice at junction of column and beamsas per approved drawings, including necessary MS fabrication work to support GRC structure, necessary scaffolding at all levels and staging Basement Floor
Providing and fixing in position factory made precast Glass fiber reinforced concrete (GRC etc complete Ground Floor
Providing and fixing in position factory made precast Glass fiber reinforced concrete (GRC etc complete First Floor
Providing and fixing in position factory made precast Glass fiber reinforced concrete (GRC etc complete Second Floor
Providing and fixing in position factory made precast Glass fiber reinforced concrete (GRC etc complete Third Floor
Providing and fixing in position factory made precast Glass fiber reinforced concrete (GRC etc complete Fourth Floor
Providing and fixing in position factory made precast Glass fiber reinforced concrete (GRC etc complete Fifth Floor
Providing and fixing GRC/FRP decorative cornice/architraves /mouldings and other details of various heights as mentioned below including grooves in wall, opening side vertical band, architraves, lintels etc. complete as per original detailing including scroll designs, floral designs, dentals, flutings etc., Item to include checking all surfaces for proper line and level, scaffolding etc. complete. Item includes preparing upto 5 samples for the Architects approval. Item to include making of the clay model and mould for the decorative cornice and supply of the decorative cornice as per approved sample executed in fiber glass material Ground Floor
Providing and fixing GRC/FRP decorative cornice/architraves /mouldings and other details First Floor
Providing and fixing GRC/FRP decorative cornice/architraves /mouldings and other details Fourth Floor
Providing and fixing GRC/FRP decorative cornice/architraves /mouldings and other details Fifth Floor
Providing and fixing GRC/FRP decorative cornice/architraves /mouldings and other details of various heights as mentioned below including grooves in wall, opening side vertical band, architraves, lintels etc. complete as per original detailing including scroll designs, floral designs, dentals, flutings etc., Item to include checking all surfaces for proper line and level, scaffolding etc. complete. Item includes preparing upto 5 samples for the Architects approval. Item to include making of the clay model and mould for the decorative cornice and supply of the decorative cornice as per approved sample executed in fiber glass material Ground Floor
Providing and fixing GRC/FRP decorative cornice/architraves /mouldings and other details First Floor
Providing and fixing GRC/FRP decorative cornice/architraves /mouldings and other details Fourth Floor
Providing and fixing GRC/FRP decorative cornice/architraves /mouldings and other details Fifth Floor
Providing and fixing GRC/FRP decorative cornice/architraves /mouldings and other details of various heights as mentioned below including grooves in wall, opening side vertical band, architraves, lintels etc. complete as per original detailing including scroll designs, floral designs, dentals, flutings etc., Item to include checking all surfaces for proper line and level, scaffolding etc. complete. Item includes preparing upto 5 samples for the Architects approval. Item to include making of the clay model and mould for the decorative cornice and supply of the decorative cornice as per approved sample executed in fiber glass material Ground Floor
Providing and fixing GRC/FRP decorative cornice/architraves /mouldings and other details First Floor
Providing and fixing GRC/FRP decorative cornice/architraves /mouldings and other details Fourth Floor
Providing and fixing GRC/FRP decorative cornice/architraves /mouldings and other details Fifth Floor
Providing and fixing GRC panels/freize as per design to be fitted on walls, or above doors as indicated by the Architect. Painting of the ceiling to be paid as per relevant Item. The design of the panel to include mouldings on the edge, designs within the mouldings varying from any shape or size within the outer edge as shown in the drawign and the entire area to be detailed and made in profile with mouldings, dentals, fluting, floral details, bosses, etc., Item includes preparing upto 5 samples for the Architects approval. Item to include making of the clay model and mould for the decorative cornice and supply of the decorative cornice as per approved sample executed in fiber glass material Mode of Measurement: the entire area of the panel/freize to be paid in area from out to out of the moulding edge. Nosthing extra to be charged for details or designs which are part of the false ceilign design under aNosther item. Basement Floor
Providing and fixing GRC panels/freize as per design to be fitted on walls etc complete Ground Floor
Providing and fixing GRC panels/freize as per design to be fitted on walls etc complete First Floor
Providing and fixing GRC panels/freize as per design to be fitted on walls etc complete Second Floor
Providing and fixing GRC panels/freize as per design to be fitted on walls etc complete Third Floor
Providing and fixing GRC panels/freize as per design to be fitted on walls etc complete Fourth Floor
Providing and fixing GRC panels/freize as per design to be fitted on walls etc complete Fifth Floor
Providing & Fixing in position, Acoustical Panelling made from 12mm wp Ply wood & 1.5mm laminate on, 50 x 50 mm Sal-wood frame of 600 x 600 c to c having wooden supports from wall of required length, in front of 1000 Gsm synthetic wool 50 mm thick with chicken mesh on wall side, including cost of required Cut-Outs, decorative mouldings / finishing-items / paint & Scaffolding, as per Architectural & Acoustical Design & Instructions & Complete in all aspects.including all materials labour,finishing etc complete Ground Floor
Providing & Fixing in position, Acoustical Panelling etc complete First Floor
Providing & Fixing in position, Acoustical Panelling etc complete Second Floor
Providing & Fixing in position, Acoustical Panelling etc complete Third Floor
Providing & Fixing in position, Acoustical Panelling etc complete Fourth Floor
Providing & Fixing in position, Acoustical Panelling etc complete Fifth Floor
Providing & Fixing in position, Acoustical Panelling made from Fabric wrapped Compressed polyester fibre nonwoven 9 mm panels on, 50 x 50 mm sal-wood frame of 600 x 600 c to c having wooden supports from wall of required length, in front of 1000 gsm synthetic wool 50 mm thick with chicken mesh on wall side, including cost of required Cut-Outs, decorative mouldings / finishing-items / paint & Scaffolding, as per Architectural & Acoustical Design & Instructions & Complete in all aspects.including all materials labour,finishing etc complete Ground Floor
Providing & Fixing in position, Acoustical Panelling made from Fabric wrapped Compressed polyester fibre etc complete First Floor
Providing & Fixing in position, Acoustical Panelling made from Fabric wrapped Compressed polyester fibre etc complete Second Floor
Providing & Fixing in position, Acoustical Panelling made from Fabric wrapped Compressed polyester fibre etc complete Third Floor
Providing & Fixing in position, Acoustical Panelling made from Fabric wrapped Compressed polyester fibre etc complete Fourth Floor
Providing & Fixing in position, Acoustical Panelling made from Fabric wrapped Compressed polyester fibre etc complete Fifth Floor
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. Basement Floor
Providing sand faced plaster externally etc complete Ground Floor
Providing sand faced plaster externally etc complete First Floor
Providing sand faced plaster externally etc complete Second Floor
Providing sand faced plaster externally etc complete Third Floor
Providing sand faced plaster externally etc complete Fourth Floor
Providing sand faced plaster externally etc complete Fifth Floor
Providing sand faced plaster externally etc complete Terrace Floor
Providing neeru finish to plastered surfaces in all positions including scaffolding and curing etc. complete. Basement Floor
Providing fine cement finish 1.5 mm thick over green plaster surface including scaffolding curing etc. complete. Basement Floor
Providing patti/ band 75mm wide on plastered surface 12 mm to 15 mm thick in C.M. 1:3 line and level including neat finishing scaffolding curing etc. complete. Basement Floor
Providing patti/ band 75mm wide on plastered surface etc complete Ground Floor
Providing patti/ band 75mm wide on plastered surface etc complete First Floor
Providing patti/ band 75mm wide on plastered surface etc complete Second Floor
Providing patti/ band 75mm wide on plastered surface etc complete Third Floor
Providing patti/ band 75mm wide on plastered surface etc complete Fourth Floor
Providing patti/ band 75mm wide on plastered surface etc complete Fifth Floor
Providing patti/ band 75mm wide on plastered surface etc complete Terrace Floor
Providing patti/ band 100mm wide on plastered surface 12 mm to 15 mm thick in C.M. 1:3 line and level including neat finishing scaffolding curing etc. complete. Basement Floor
Providing patti/ band 100mm wide on plastered surface etc complete Ground Floor
Providing patti/ band 100mm wide on plastered surface etc complete First Floor
Providing patti/ band 100mm wide on plastered surface etc complete Second Floor
Providing patti/ band 100mm wide on plastered surface etc complete Third Floor
Providing patti/ band 100mm wide on plastered surface etc complete Fourth Floor
Providing patti/ band 100mm wide on plastered surface etc complete Fifth Floor
Providing patti/ band 100mm wide on plastered surface etc complete Terrace Floor
Providing patti/ band 150mm wide on plastered surface 12 mm to 15 mm thick in C.M. 1:3 line and level including neat finishing scaffolding curing etc. complete. Basement Floor
Providing patti/ band 150mm wide on plastered surface etc complete Ground Floor
Providing patti/ band 150mm wide on plastered surface etc complete First Floor
Providing patti/ band 150mm wide on plastered surface etc complete Second Floor
Providing patti/ band 150mm wide on plastered surface etc complete Third Floor
Providing patti/ band 150mm wide on plastered surface etc complete Fourth Floor
Providing patti/ band 150mm wide on plastered surface etc complete Fifth Floor
Providing patti/ band 150mm wide on plastered surface etc complete Terrace Floor
Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete /B.B.masonry and or tying by binding wire etc. complete. Basement Floor
Providing and fixing chicken mesh of 22 gauge etc compelte Ground Floor
Providing and fixing chicken mesh of 22 gauge etc compelte First Floor
Providing and fixing chicken mesh of 22 gauge etc compelte Second Floor
Providing and fixing chicken mesh of 22 gauge etc compelte Third Floor
Providing and fixing chicken mesh of 22 gauge etc compelte Fourth Floor
Providing and fixing chicken mesh of 22 gauge etc compelte Fifth Floor
Providing and fixing chicken mesh of 22 gauge etc compelte Terrace Floor
Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete. Basement Floor
Providing and applying Two coats of wall care Putty etc complete Ground Floor
Providing and applying Two coats of wall care Putty etc complete First Floor
Providing and applying Two coats of wall care Putty etc complete Second Floor
Providing and applying Two coats of wall care Putty etc complete Third Floor
Providing and applying Two coats of wall care Putty etc complete Fourth Floor
Providing and applying Two coats of wall care Putty etc complete Fifth Floor
Providing and applying Two coats of wall care Putty etc complete Terrace Floor
Providing and fixing false ceiling with eco-friendly light-weight calcium silicate tiles of spintone surface texture aerolite make or equivalent of size 595mm x 595mm having 15mm thick densified micro look edge and 100% humidity resistance incombustible as per BS 46part IV and thermal conductivity 0.043 w/m 0 KC and NRC 0.50 placed in true horizontal level suspended grid of size 600x600mm made from hot dipped G.I. steel sections ion silhouette profile, rotary stitched double webbed white with 6mm reveal profile (white/black), wherein, main T runner of size 42mmx14mm between main tee 600mm center-tocenter and secondary cross T of size 33x14x0.43mm thick of length 600mm long spaced inter-locked at middle of the first crossed T in each panel to form grid of 1200mmx600mm resting on periphery wall Profile wall section 19mm (7+7) x 19mmx0.40thicknesses and laying false ceiling for services like diffusers grills including cutting, making opening for light fittings, fixtures, , smoke detectors etc., wherever required. Main T runners suspended from ceiling with using G.I. soffit cleats of size 25x35x1.6 mm of required length fixed to the ceiling with 6mm dia and 50mm long dash fastener, 4mm dia G.I. adjustable rods with powder- Ground Floor
Providing and fixing false ceiling etc complete First Floor
Providing and fixing false ceiling etc complete Second Floor
Providing and fixing false ceiling etc complete Third Floor
Providing and fixing false ceiling etc complete Fourth Floor
Providing and fixing false ceiling etc complete Fifth Floor
Providing groove to required size at specified location as directed by Engineer, at junction of brick masonry wall and R.C.C beams or Column, at junction of composite masonry, including scaffolding, finishing, curing etc. complete. Basement Floor
Providing groove to required size etc complete Ground Floor
Providing groove to required size etc complete First Floor
Providing groove to required size etc complete Second Floor
Providing groove to required size etc complete Third Floor
Providing groove to required size etc complete Fourth Floor
Providing groove to required size etc complete Fifth Floor
Terrace Floor
Providing and laying Vitrified MATT finish having decorative type of size 1000 millimeter x 1000 millimeter of 8 to 10 millimeter thickness with bonding chemical and confirming to IS 15622-2006 (Group Bla) of approved make shade and pattern for flooring in required position laid on a bed of bonding chemical filling joints curing and cleaning etc .complete. Basement Floor
Providing and laying Vitrified MATT finish etc complete Ground Floor
Providing and laying Vitrified MATT finish etc complete First Floor
Providing and laying Vitrified MATT finish etc complete Second Floor
Providing and laying Vitrified MATT finish etc complete Third Floor
Providing and laying Vitrified MATT finish etc complete Fourth Floor
Providing and laying Vitrified MATT finish etc complete Fifth Floor
Providing and laying vitrified stone effect finish tiles having size 590 to 605 mm x 590 to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 (Group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including required position laid on a bed of 1:4 cement mortarincluding neat cement float, filling joints, curign and cleaning etc. complete. Basement Floor
Providing and laying vitrified stone for dado & Skirting etc complete Ground Floor
Providing and laying vitrified stone for dado & Skirting etc complete First Floor
Providing and laying vitrified stone for dado & Skirting etc complete Second Floor
Providing and laying vitrified stone for dado & Skirting etc complete Third Floor
Providing and laying vitrified stone for dado & Skirting etc complete Fourth Floor
Providing and laying vitrified stone for dado & Skirting etc complete Fifth Floor
Providing and laying vitrified stone for dado & Skirting etc complete Terrace Floor
Providing and fixing heavy duty inter locking concrete Coloured paving blocks of 80 mm thickness of having a strength of 300 Kilogram/Sq.cm. of approved quality and shape on a bed of crushed sand of 25 to 30 mm thick including skirting joints and cleaning etc. complete Basement Floor
Providing and laying machine cut machine Polished Kota stone flooring 25mm to 30mm thick and required width in plain/ diamond pattern on bed of 1:6 C. M. including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete. Basement Floor
Providing and laying machine cut machine Polished Kota stone flooring etc complete Ground Floor
Providing and laying machine cut machine Polished Kota stone flooring etc complete First Floor
Providing and laying machine cut machine Polished Kota stone flooring etc complete Second Floor
Providing and laying machine cut machine Polished Kota stone flooring etc complete Third Floor
Providing and laying machine cut machine Polished Kota stone flooring etc complete Fourth Floor
Providing and laying machine cut machine Polished Kota stone flooring etc complete Fifth Floor
Providing and laying machine cut machine Polished Kota stone flooring etc complete Terrace Floor
Providing Mirror polishing to Kota Stone including using all necessary stones and equipments cleaning, washing etc. complete. For Flooring Basement Floor
Providing Mirror polishing to Kota Stone for flooring etc complete Ground Floor
Providing Mirror polishing to Kota Stone for flooring etc complete First Floor
Providing Mirror polishing to Kota Stone for flooring etc complete Second Floor
Providing Mirror polishing to Kota Stone for flooring etc complete Third Floor
Providing Mirror polishing to Kota Stone for flooring etc complete Fourth Floor
Providing Mirror polishing to Kota Stone for flooring etc complete Fifth Floor
Providing Mirror polishing to Kota Stone for flooring etc complete Terrace Floor
Providing and laying machine cut machine polished machine cut Kota stone slabs 20 to 25 mm thick for treads and risers of steps and staircases, with rounded nosing for the treads on a bed of 1:4 cement mortar including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete. Basement Floor
Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete. Basement Floor
Providing and laying in position flooring of telephone black etc complete Ground Floor
Providing and laying in position flooring of telephone black etc complete First Floor
Providing and laying in position flooring of telephone black etc complete Second Floor
Providing and laying in position flooring of telephone black etc complete Third Floor
Providing and laying in position flooring of telephone black etc complete Fourth Floor
Providing and laying in position flooring of telephone black etc complete Fifth Floor
Providing and fixing machine cut machine polished 18 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with full moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete. Basement Floor
Providing and fixing machine cut machine polished etc complete Ground Floor
Providing and fixing machine cut machine polished etc complete First Floor
Providing and fixing machine cut machine polished etc complete Second Floor
Providing and fixing machine cut machine polished etc complete Third Floor
Providing and fixing machine cut machine polished etc complete Fourth Floor
Providing and fixing machine cut machine polished etc complete Fifth Floor
Providing leather finished polishing to Granite Stone slab by continuous grinding in 4 coats of different bits to receive rough and matt finish including buffing process before laying and fixing of stone as per drawing and design, including cleaning, washing and finishing etc. complete. Basement Floor
Providing leather finished polishing to Granite Stone slab etc complete Ground Floor
Providing leather finished polishing to Granite Stone slab etc complete First Floor
Providing leather finished polishing to Granite Stone slab etc complete Second Floor
Providing leather finished polishing to Granite Stone slab etc complete Third Floor
Providing leather finished polishing to Granite Stone slab etc complete Fourth Floor
Providing leather finished polishing to Granite Stone slab etc complete Fifth Floor
Providing and fixing machine cut mirror polished 18 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone partition with full moulding the edges etc. complete. One side polish Ground Floor
Providing and fixing machine cut mirror polished granite stone partition etc complete First Floor
Providing and fixing machine cut mirror polished granite stone partition etc complete Second Floor
Providing and fixing machine cut mirror polished granite stone partition etc complete Third Floor
Providing and fixing machine cut mirror polished granite stone partition etc complete Fourth Floor
Providing and fixing machine cut mirror polished granite stone partition etc complete Fifth Floor
Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete. Basement Floor
Providing and applying priming coat etc complete Ground Floor
Providing and applying priming coat etc complete First Floor
Providing and applying priming coat etc complete Second Floor
Providing and applying priming coat etc complete Third Floor
Providing and applying priming coat etc complete Fourth Floor
Providing and applying priming coat etc complete Fifth Floor
Providing and applying washable oil-bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces. (excluding the primer coat.) etc. complete. Basement Floor
Providing and applying washable oil-bound distemper etc complete Ground Floor
Providing and applying washable oil-bound distemper etc complete First Floor
Providing and applying washable oil-bound distemper etc complete Second Floor
Providing and applying washable oil-bound distemper etc complete Third Floor
Providing and applying washable oil-bound distemper etc complete Fourth Floor
Providing and applying washable oil-bound distemper etc complete Fifth Floor
Providing and applying 2 coats of 100% Pure acrylic low VOC and APEO & HCHO free water based paint of approved colour that belongs to class 1 flame spread resistance of approved make Paint should provide durable and long lasting silk finish with a high crack tolerance of upto 1mm. Paint should have an oustanding washability with high resistance to wide range of bacteria and fungus. Paint has to be applied on smooth and uniform surface prepared by an acrylic copolymer low VOC & Odour putty. This surface should be primed with water based low VOC Primer. The work activity should cover all aspects of applying paints from surface preparation as directed by Engineer in charge. Basement Floor
Providing and applying 2 coats of 100% Pure acrylic low VOC etc complete Ground Floor
Providing and applying 2 coats of 100% Pure acrylic low VOC etc complete First Floor
Providing and applying 2 coats of 100% Pure acrylic low VOC etc complete Second Floor
Providing and applying 2 coats of 100% Pure acrylic low VOC etc complete Third Floor
Providing and applying 2 coats of 100% Pure acrylic low VOC etc complete Fourth Floor
Providing and applying 2 coats of 100% Pure acrylic low VOC etc complete Fifth Floor
Providing and applying 2 coats of 100% Pure acrylic low VOC etc complete Terrace Floor
Providing and applying 2 Coats of 100% Pure acrylic water based paint with special heat reflectance property to withstand the harsh climate for period of atleast 10 years of approved make. Paint system should provide durable and long lasting finish with DFT of min 90 microns and should protect against concrete carbonation with R value of minimum 600 and equivalent concrete layer thickness value of min 150 cm. Paint should have breathability property and should be able to cover hairline cracks in the surface upto 0.5mm The paint has to be applied on a coat of high quality acrylic copolymer based alkali resistant primer with excellent penetrating properties including cleaning, with all leads and lifts at all levels etc. complete, as directed by Engineer in charge. Basement Floor
Providing and applying 2 Coats of 100% Pure acrylic water based paint etc complete Ground Floor
Providing and applying 2 Coats of 100% Pure acrylic water based paint etc complete First Floor
Providing and applying 2 Coats of 100% Pure acrylic water based paint etc complete Second Floor
Providing and applying 2 Coats of 100% Pure acrylic water based paint etc complete Third Floor
Providing and applying 2 Coats of 100% Pure acrylic water based paint etc complete Fourth Floor
Providing and applying 2 Coats of 100% Pure acrylic water based paint etc complete Fifth Floor
Providing and applying 2 Coats of 100% Pure acrylic water based paint etc complete Terrace Floor
Providing and applying Dezzly texture paint of Hammer / Screetech on the external plastered surface of approved quality. As directed by Engineer in charge ( Approved by SE PWD Nanded ) Basement Floor
Providing and applying Dezzly texture paint etc complete Ground Floor
Providing and applying Dezzly texture paint etc complete First Floor
Providing and applying Dezzly texture paint etc complete Second Floor
Providing and applying Dezzly texture paint etc complete Third Floor
Providing and applying Dezzly texture paint etc complete Fourth Floor
Providing and applying Dezzly texture paint etc complete Fifth Floor
Providing and applying two coats Apex Ultima Puranature Anti-Pollution Or equivalent approved brand, paint should decomposes organic substances and inorganic gases(NOx, VOC‘s, CO, SOx, formaldehydes, etc.) in presence of natural or artificial light. It contains Graphene and nanoparticles of titanium oxide. and Absorbs CO2 (4.8 Kilogram/15 l). plaster crack should be filled by Acrylic base Crack seal/Textured Crack filler, Paint has to applied on one coat of Apex Ultima Puranature Anti-Pollution Primer or Equivalent. Warranty Should be given by the Manufaturer The work should be done by the Manufacturer Recommended applicator and he should be able to furnish stage wise onsite technical reports from the concerned company technologist. Basement Floor
Providing and applying two coats Apex etc complete Ground Floor
Providing and applying two coats Apex etc complete First Floor
Providing and applying two coats Apex etc complete Second Floor
Providing and applying two coats Apex etc complete Third Floor
Providing and applying two coats Apex etc complete Fourth Floor
Providing and applying two coats Apex etc complete Fifth Floor
Providing and applying two coats Apex etc complete Terrace Floor
Providing and applying two coats of synthetic enamel paint of approved colour to new /old structural steel work and wood work in buildings, including scaffolding if necessary, cleaning and preparing the surface (excluding primer coat) etc. complete. Basement Floor
Providing and applying two coats of synthetic enamel paint etc complete Ground Floor
Providing and applying two coats of synthetic enamel paint etc complete First Floor
Providing and applying two coats of synthetic enamel paint etc complete Second Floor
Providing and applying two coats of synthetic enamel paint etc complete Third Floor
Providing and applying two coats of synthetic enamel paint etc complete Fourth Floor
Providing and applying two coats of synthetic enamel paint etc complete Fifth Floor
Providing and applying two coats of synthetic enamel paint etc complete Terrace Floor
Providing and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete Ground Floor
Providing and fixing frame with / without ventilator etc complete First Floor
Providing and fixing Country teak wood Four leaf paneled shutters, 35 mm thick style and rail and 25 mm thick panels without ventilator as per detailed drawing excluding the door frame, stainless steel fixtures and fastening and finishing the wood work with oil painting 3 coats complete Ground Floor
Providing and fixing Country cut teak wood double or single leaf panelled shutters, 35 mm thick style top and freze rail 95 x 35 thick with lock and bottam rail 195 x 25 mm thick and panels without ventilator as per detailed drawing excluding the door frame, stainless steel fixtures and fastening and finishing the wood work with oil painting 3 coats complete First Floor
Providing and fixing 34 mm thick moulded door shutter consisting of solid core single leaf flush door of 30 mm thickness lipped with 15 mm ( 5mm x 3) thick x 30 mm width on one style and top rail and 10 mm (5mm x 2) thick x 30 mm width on other style and bottom rails. The inner panels laminated with 2 mm thick termite proof, water proof and fire resistant moulded PVC sheet with 2,4,6 design in different plain and /or prelim colours on one side after routing the moulded design on flush doors and 2 mm plain and /or pre lam PVC on other side using rubber adhesive on flush door and solvent cement adhesive on the PVC lipping etc. as per direction of Engineer in charge and manufacturers specification and drawing etc.complete. Basement Floor
Providing and fixing 34 mm thick moulded door shutter etc complete Ground Floor
Providing and fixing 34 mm thick moulded door shutter etc complete First Floor
Providing and fixing 34 mm thick moulded door shutter etc complete Second Floor
Providing and fixing 34 mm thick moulded door shutter etc complete Third Floor
Providing and fixing 34 mm thick moulded door shutter etc complete Fourth Floor
Providing and fixing 34 mm thick moulded door shutter etc complete Fifth Floor
Providing and fixing 34 mm thick moulded door shutter etc complete Terrace Floor
Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 mm x 1.22 mm box type, 5 mm thick sheet glass louvers, of approved quality etc. complete. Ground Floor
Providing and fixing in position powder coated aluminium louvered windows / ventilator etc complete First Floor
Providing and fixing in position powder coated aluminium louvered windows / ventilator etc complete Second Floor
Providing and fixing in position powder coated aluminium louvered windows / ventilator etc complete Third Floor
Providing and fixing in position powder coated aluminium louvered windows / ventilator etc complete Fourth Floor
Providing and fixing in position powder coated aluminium louvered windows / ventilator etc complete Fifth Floor
Providing and fixing in position anodised (as per IS 1868/1982) Aluminium fixed staggered ( Z Type) Ventilator with aluminium rectangular pipe 63 mm x 38.10 mm x 1.22 mm at weight 0.650 Kilogram/Running metre, Aluminium angle of size 15 mm x 15 mm x 1 mm,aluminium channel of 9 mm sizes, S.S.mosquito net of 304 Grade,4 mm thick float glass per detailed drawing and as directed by Engineer in charge etc.complete. Basement Floor
Providing and fixing fiber glass reinforced polyster door shutter 35 mm thick as per IS 14856 (2000) (Reaffirmed 2006) without ventilator including chromium plated fixtures and fastening with chromium plated handles on both sides, etc complete. Ground Floor
Providing and fixing fiber glass reinforced polyster door shutter 35 mm thick etc complete First Floor
Providing and fixing fiber glass reinforced polyster door shutter 35 mm thick etc complete Second Floor
Providing and fixing fiber glass reinforced polyster door shutter 35 mm thick etc complete Third Floor
Providing and fixing fiber glass reinforced polyster door shutter 35 mm thick etc complete Fourth Floor
Providing and fixing fiber glass reinforced polyster door shutter 35 mm thick etc complete Fifth Floor
Providing and fixing in position. (as per I.S.1868 / 1982) Aluminium sliding window of two tracks with rectangular pipe having overall dimension 63.50 x 38.10 x 1.02 mm at weight 0.547 Kilogram/Running metre. and window frame bottom track section 61.85 x 31.75 x 1.20 mm at weight 0.695 Kilogram/Running metre. Top and side track section 61.85 x 31.75 x 1.30 mm at weight 0.659 Kilogram/Running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram / Running metre. Inter locking section 40 x 18 x1.10 mm at weight 0.469 Kilogram/Running metre. And handle section 40 x 18 x 1.25 mm at weight 0.417 Kilogram / Running metre. and top section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. As per detailed drawings and as directed by Engineer in charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass with all required screws and nuts etc, complete. With powder coating with box Ground Floor
Providing and fixing in position. (as per I.S.1868 / 1982) Aluminium sliding window of two tracks etc complete First Floor
Providing and fixing in position. (as per I.S.1868 / 1982) Aluminium sliding window of two tracks etc complete Second Floor
Providing and fixing in position. (as per I.S.1868 / 1982) Aluminium sliding window of two tracks etc complete Third Floor
Providing and fixing in position. (as per I.S.1868 / 1982) Aluminium sliding window of two tracks etc complete Fourth Floor
Providing and fixing in position. (as per I.S.1868 / 1982) Aluminium sliding window of two tracks etc complete Fifth Floor
Providing and fixing in position (as per 1868 / 1982) Aluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 mm at weight 0.637 Kilogram/Running metre. with window frame bottom track section 92 x 31.75 x 1.30 mm at weight 1.070 Kilogram/Running metre.. Top and side track section 92 x 31.75 x 1.30 mm at weight 0.933 Kilogram/Running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 Kilogram/Running metre. and handle and top section 40 x 18 x 1.25 mm at weight o.417 Kilogram/Running metre. As per detailed drawings and as directed by Engineerincharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc, complete. With powder coating with box Basement Floor
Providing and fixing in position (as per 1868 / 1982) Aluminium sliding window of three tracks etc complete Ground Floor
Providing and fixing in position (as per 1868 / 1982) Aluminium sliding window of three tracks etc complete First Floor
Providing and fixing in position (as per 1868 / 1982) Aluminium sliding window of three tracks etc complete Second Floor
Providing and fixing in position (as per 1868 / 1982) Aluminium sliding window of three tracks etc complete Third Floor
Providing and fixing in position (as per 1868 / 1982) Aluminium sliding window of three tracks etc complete Fourth Floor
Providing and fixing in position (as per 1868 / 1982) Aluminium sliding window of three tracks etc complete Fifth Floor
Providing and applying antipeel paint of approved make & approved brand exterior Emulsion paint of approved quality, colour and shade to old and new surface in two coats, including exterior acrylic primer coat, scaffolding, preparing the surface etc. complete (Heat Reflective Paint). Basement Floor
Providing and applying antipeel paint etc complete Ground Floor
Providing and applying antipeel paint etc complete First Floor
Providing and applying antipeel paint etc complete Second Floor
Providing and applying antipeel paint etc complete Third Floor
Providing and applying antipeel paint etc complete Fourth Floor
Providing and applying antipeel paint etc complete Fifth Floor
a) Supplying and fixing in position Aluminium four track sliding windows with outer frame made from section of over all size 122 mm x 45 mm, bottom section with drain section track weighing 1.83Kilogramper metre and top and side section of size 122x 31.75 mm weighing 1.15Kilogramper running metre with shutter sections made of 18 mm x 40 mm size having average weight of 0.6Kilogramper running metre (or as required size) with change in proportionate weight, with 6 mm float glass in three equal panels and alluminium coated stainless steel mosquito net in one (2/3 of opening) panel fixed with new neoprene gasket, shutters to be provided with nylon encased stainless steel rollers, necessary locks and handles complete. Basement Floor
a) Supplying and fixing in position Aluminium four track sliding windows etc complete Ground Floor
a) Supplying and fixing in position Aluminium four track sliding windows etc complete First Floor
a) Supplying and fixing in position Aluminium four track sliding windows etc complete Second Floor
a) Supplying and fixing in position Aluminium four track sliding windows etc complete Third Floor
a) Supplying and fixing in position Aluminium four track sliding windows etc complete Fourth Floor
Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing, etc. complete. Basement Floor
Providing and laying telephone black granite for door frame/ dado/ window boxing etc complete Ground Floor
Providing and laying telephone black granite for door frame/ dado/ window boxing etc complete First Floor
Providing and laying telephone black granite for door frame/ dado/ window boxing etc complete Second Floor
Providing and laying telephone black granite for door frame/ dado/ window boxing etc complete Third Floor
Providing and laying telephone black granite for door frame/ dado/ window boxing etc complete Fourth Floor
Providing and laying telephone black granite for door frame/ dado/ window boxing etc complete Fifth Floor
Providing and laying telephone black granite for door frame/ dado/ window boxing etc complete Terrace Floor
Providing and fixing M40 grade thick vibrated pull cast or similar type concrete frame with chamfer conforming to I.S. 65241983 having 6 mm dia. bars 3 Nos. And stirrups @250 mm c/c and fixing in wall with 6 Nos of hold fast of 12 mm dia bars 500 mm long including primer and oil painting etc, complete) frame size 60 mm x 100 mm . Terrace Floor
Providing and fixing mild steel grill work for windows, ventilators etc. 25 Kilogram/Square Metre as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete. Basement Floor
Providing and fixing mild steel grill work for windows, ventilators etc. 25 Kilogram/Square Metre Ground Floor
shiva
Providing and fixing mild steel grill work for windows, ventilators etc. 25 Kilogram/Square Metre Second Floor
Providing and fixing mild steel grill work for windows, ventilators etc. 25 Kilogram/Square Metre Third Floor
Providing and fixing mild steel grill work for windows, ventilators etc. 25 Kilogram/Square Metre Fourth Floor
Providing and fixing mild steel grill work for windows, ventilators etc. 25 Kilogram/Square Metre Fifth Floor
Providing and fixing mild steel grill work for windows, ventilators etc. 25 Kilogram/Square Metre Terrace Floor
Providing and Fixing mat finish stainless steel (of 302 grade ) railing with top pipe of 50 mm dia. and vertical pipe of 38 mm dia at 0.60 m c/c or as required and horizontal pipes of 25 mm dia in three rows, all pipes of 2 mm thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 mm dia above newel post of 75 mm diameter etc. complete (Prior approval of sample and brand by Ex.Engineer is necessary before use) Basement Floor
Providing and Fixing mat finish stainless steel (of 302 grade ) railing etc complete Ground Floor
Providing and Fixing mat finish stainless steel (of 302 grade ) railing etc complete First Floor
Providing and Fixing mat finish stainless steel (of 302 grade ) railing etc complete Second Floor
Providing and Fixing mat finish stainless steel (of 302 grade ) railing etc complete Third Floor
Providing and Fixing mat finish stainless steel (of 302 grade ) railing etc complete Fourth Floor
Providing and Fixing mat finish stainless steel (of 302 grade ) railing etc complete Fifth Floor
Providing and Fixing mat finish stainless steel (of 302 grade ) railing etc complete Terrace Floor
Grab bars-Providing SS grab bars set for accessible toilets comprising of 4 nos. Grab bars as specified below.(1 nos. wing grab bar + 1 nos. L shaped grab bar + 2 nos. straight grab bars = 1 typical set) 27a) Swing grab bar (1 NOS) Providing a S.S. 304 SWING HANDICAP GRAB BAR - 700 mm and of DIA: 32MM and thickness 1.5mm of the roved brand and make. 27b) L Shaped grab bar (1 NOS) Providing S.S. 304 L SHAPED DISABLED GRAB BAR of IZE-600MM (H) X 600MM (D) and 32MM DIA. and thickness mm of the approved brand and make. 27c) Straight grab bar (2 NOS) Providing S.STEEL 304 GRAB RAIL (600 MM),32MM DIA. and thickness 1.5mm of the approved brand and make. Ground Floor
Grab bars-Providing SS grab bars set for accessible toilets etc complete First Floor
Grab bars-Providing SS grab bars set for accessible toilets etc complete Second Floor
Grab bars-Providing SS grab bars set for accessible toilets etc complete Third Floor
Grab bars-Providing SS grab bars set for accessible toilets etc complete Fourth Floor
Providing and fixing shutter to wall cupboard made from 19 mm thick Teak particle board with approved coloured laminated face 1.5 mm thick bonded with phenol formaldehyde synthetic resin B.W.P. grade including lipping beading iron oxidised fixtures and fastening and oil primer coat etc. complete. (Excluding cupboard frame). Ground Floor
Providing and fixing shutter to wall cupboard First Floor
Providing and fixing shutter to wall cupboard Second Floor
Providing and fixing shutter to wall cupboard Third Floor
Providing and fixing shutter to wall cupboard Fourth Floor
Providing and fixing shutter to wall cupboard Fifth Floor
Providing and fixing C.P. 2 Way BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge. (Jaquar / Equivalent make Confirming Green Bldg Certificate) Ground Floor
Providing and fixing C.P. 2 Way BIB cock First Floor
Providing and fixing C.P. 2 Way BIB cock Second Floor
Providing and fixing C.P. 2 Way BIB cock Third Floor
Providing and fixing C.P. 2 Way BIB cock Fourth Floor
Providing and fixing C.P. 2 Way BIB cock Fifth Floor
Providing and fixing 25mm diameter water meter with non-return valve including strainer, sockets/ union nut and including water meter box making locking arrangement and lock. [Without chamber]. Basement Floor
Providing and fixing 15 mm dia. screw down bib/ stop tap of brass including necessary socket union nut complete. Ground Floor
Providing and fixing 15 mm dia. screw down bib/ stop tap First Floor
Providing and fixing 15 mm dia. screw down bib/ stop tap Second Floor
Providing and fixing 15 mm dia. screw down bib/ stop tap Third Floor
Providing and fixing 15 mm dia. screw down bib/ stop tap Fourth Floor
Providing and fixing 15 mm dia. screw down bib/ stop tap Fifth Floor
Providing and fixing 20 mm dia. screw down bib/ stop tap of brass including necessary socket union nut complete. Ground Floor
Providing and fixing 20 mm dia. screw down bib/ stop tap First Floor
Providing and fixing 20 mm dia. screw down bib/ stop tap Second Floor
Providing and fixing 20 mm dia. screw down bib/ stop tap Third Floor
Providing and fixing 20 mm dia. screw down bib/ stop tap Fourth Floor
Providing and fixing 20 mm dia. screw down bib/ stop tap Fifth Floor
Providing and fixing screw down 15 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete Ground Floor
Providing and fixing screw down 15 mm dia. wheeled stop tap First Floor
Providing and fixing screw down 15 mm dia. wheeled stop tap Second Floor
Providing and fixing screw down 15 mm dia. wheeled stop tap Third Floor
Providing and fixing screw down 15 mm dia. wheeled stop tap Fourth Floor
Providing and fixing screw down 15 mm dia. wheeled stop tap Fifth Floor
Providing and fixing push cock (Self closing tap) symet type of 15 mm dia. including necessary socket, testing etc. complete. (Jaquar / Equivalent make Confirming Green Bldg Certificate) Ground Floor
Providing and fixing push cock (Self closing tap) First Floor
Providing and fixing push cock (Self closing tap) Second Floor
Providing and fixing push cock (Self closing tap) Third Floor
Providing and fixing push cock (Self closing tap) Fourth Floor
Providing and fixing push cock (Self closing tap) Fifth Floor
Providing and fixing coloured glazed earthenware Wash Hand Basin of 63 cm x 45 cm size including cold water pillar tap/cold and hot water pillar tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connection including P.V.C. waste pipe and trap up to the outside face of the wall. (Jaquar / Equivalent make Confirming Green Bldg Certificate) Ground Floor
Providing and fixing coloured glazed earthenware Wash Hand Basin First Floor
Providing and fixing coloured glazed earthenware Wash Hand Basin Second Floor
Providing and fixing coloured glazed earthenware Wash Hand Basin Third Floor
Providing and fixing coloured glazed earthenware Wash Hand Basin Fourth Floor
Providing and fixing coloured glazed earthenware Wash Hand Basin Fifth Floor
Providing and fixing 15cm x 10cm salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap. Ground Floor
Providing and fixing 15cm x 10cm salt glazed stoneware gully trap First Floor
Providing and fixing 15cm x 10cm salt glazed stoneware gully trap Second Floor
Providing and fixing 15cm x 10cm salt glazed stoneware gully trap Third Floor
Providing and fixing 15cm x 10cm salt glazed stoneware gully trap Fourth Floor
Providing and fixing 15cm x 10cm salt glazed stoneware gully trap Fifth Floor
Providing and laying 100 mm dia salt glazed stoneware pipe including fittings such as bends, tees, single junction, double junctions laying, jointing (including excavation and refilling the trenches) complete. Basement Floor
Providing and laying for 150 mm dia salt glazed stoneware pipe including fittings Such as bends, tees, single junction, double junctions laying, jointing (including excavation and refilling the trenches) complete. Basement Floor
Providing and laying concrete pipes of I.S.NP. class of 150mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. Basement Floor
Providing and laying concrete pipes of I.S.NP. class of 300mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. Basement Floor
Providing , constructing and fixing 600 mm dia. Inspection chamber made up of Polypropylene / polyethylene material Having 315 mm diameter inlet(s)/outlets and with eccentric reducers as per requirement to connect 160 mm and 200 mm pipes having thickness of 5 mm and 600 mm in height, with inbuilt shaft achieve the invert depth as per site condition of wall thickness of 5 mm having R.C.C. cover and frame fixing in 150 mm thick in c.c.1:2:4, having crushed sand bed of 150 mm thick of size 750 mm dia. Including excavation and refilling the sides of chamber by ?sand crushed cushioning 150 mm thickness, connecting all required UPVC fittings with rubber lubricant etc.complete. Basement Floor
Providing and fixing 450mm x 550mm size superior type Belgium mirror with 16mm dia. nickel plated towel rod etc. complete. Ground Floor
Providing and fixing 450mm x 550mm size superior type Belgium mirror First Floor
Providing and fixing 450mm x 550mm size superior type Belgium mirror Second Floor
Providing and fixing 450mm x 550mm size superior type Belgium mirror Third Floor
Providing and fixing 450mm x 550mm size superior type Belgium mirror Fourth Floor
Providing and fixing 450mm x 550mm size superior type Belgium mirror Fifth Floor
Providing and fixing chromium plated towel rod 16 mm dia and 75 cm. in length including all accessories complete. Ground Floor
Providing and fixing chromium plated towel rod First Floor
Providing and fixing chromium plated towel rod Second Floor
Providing and fixing chromium plated towel rod Third Floor
Providing and fixing chromium plated towel rod Fourth Floor
Providing and fixing chromium plated towel rod Fifth Floor
Providing and fixing white glazed earthenware sink 600mm x 200mm x 450mm including all connection of the G.I. supply and P.V.C. waste pipes up to the outside face of the wall, cold water chromium plated screw down bib tap, rolled steel or C.I. brackets, rubber plug with chain and stop tap complete. (Jaquar / Equivalent make Confirming Green Bldg Certificate) Fifth Floor
Providing and fixing stainless steel sink of size 600 x 510 x 200 mm incluidng coupling, outlet pipe, elbow and other necessary fitting, finishing etc. complete (Jaquar / Equivalent make Confirming Green Bldg Certificate) Fifth Floor.
Providing and fixing C.P. Angular stop clock with wall flange of approved make continental including necessary sockets/union nut etc. complete. (Jaquar / Equivalent make Confirming Green Bldg Certificate) Ground Floor
Providing and fixing C.P. Angular stop clock First Floor
Providing and fixing C.P. Angular stop clock Second Floor
Providing and fixing C.P. Angular stop clock Third Floor
Providing and fixing C.P. Angular stop clock Fourth Floor
Providing and fixing C.P. Angular stop clock Fifth Floor
Providing and fixing C.P. pillar cock long neck with aerator of approed make including necessary sockets/union nut etc. complete. (Jaquar / Equivalent make Confirming Green Bldg Certificate) Ground Floor
Providing and fixing C.P. pillar cock long neck Ground Floor
Providing and fixing C.P. pillar cock long neck First Floor
Providing and fixing C.P. pillar cock long neck Second Floor
Providing and fixing C.P. pillar cock long neck Third Floor
Providing and fixing C.P. pillar cock long neck Fourth Floor
Providing and fixing C.P. pillar cock long neck Fifth Floor
Providing and fixing C.P. BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete. (Jaquar / Equivalent make Confirming Green Bldg Certificate) Ground Floor
Providing and fixing C.P. BIB cock with wall flange First Floor
Providing and fixing C.P. BIB cock with wall flange Second Floor
Providing and fixing C.P. BIB cock with wall flange Third Floor
Providing and fixing C.P. BIB cock with wall flange Fourth Floor
Providing and fixing C.P. BIB cock with wall flange Fifth Floor
Providing and fixing C.P. sink cock with raised J" shaped swinging casted spout ofapproved make including necessary sockets/ union nut etc. complete." (Jaquar / Equivalent make Confirming Green Bldg Certificate) Fifth Floor
Providing and fixing 40 mm. dia Ball cock medium type with PVC float including sockets and necessary fittings and tested as per municipal requirements etc. complete. Ground Floor
Providing and fixing 40 mm. dia Ball cock First Floor
Providing and fixing 40 mm. dia Ball cock Second Floor
Providing and fixing 40 mm. dia Ball cock Third Floor
Providing and fixing 40 mm. dia Ball cock Fourth Floor
Providing and fixing 40 mm. dia Ball cock Fifth Floor
Providing and fixing 40 mm. dia Ball cock Terrace Floor
Providing and fixing 15 mm. dia Ball cock medium type with PVC float including sockets and necessary fittings and tested as per municipal requirement etc. complete. Ground Floor
Providing and fixing 15 mm. dia Ball cock First Floor
Providing and fixing 15 mm. dia Ball cock Second Floor
Providing and fixing 15 mm. dia Ball cock Third Floor
Providing and fixing 15 mm. dia Ball cock Fourth Floor
Providing and fixing 15 mm. dia Ball cock Fifth Floor
Providing and fixing 15 mm. dia Ball cock Fifth Floor
Providing and fixing Shower Head, with shower arm of approved make mixer of including all necessary pipe fittings and connections etc. complete as directed by Engineer in charge. (Jaquar / Equivalent make Confirming Green Bldg Certificate) Ground Floor
Providing and fixing Shower Head, with shower First Floor
Providing and fixing Shower Head, with shower Second Floor
Providing and fixing Shower Head, with shower Third Floor
Providing and fixing Shower Head, with shower Fourth Floor
Providing and fixing Shower Head, with shower Fifth Floor
Providing and fixing C.P. wall mixer with provision for overhead shower with 115mm long bend pipe and wall flange of approved make including necessary sockets/union nut etc. complete. (Jaquar / Equivalent make Confirming Green Bldg Certificate) Ground Floor
Providing and fixing C.P. wall mixer First Floor
Providing and fixing C.P. wall mixer Second Floor
Providing and fixing C.P. wall mixer Third Floor
Providing and fixing C.P. wall mixer Fourth Floor
Providing and fixing C.P. wall mixer Fifth Floor
Providing and Fixing half turn 25 mm dia gun metal flushing cock including all accessories etc. complete. Ground Floor
Providing and Fixing half turn 25 mm dia gun metal First Floor
Providing and Fixing half turn 25 mm dia gun metal Second Floor
Providing and Fixing half turn 25 mm dia gun metal Third Floor
Providing and Fixing half turn 25 mm dia gun metal Fourth Floor
Providing and Fixing half turn 25 mm dia gun metal Fifth Floor
Providing and fixing Orissa Pan of size 580x445x260 mm with approved make flush valve including trap, C.I. soil and vent pipe upto outside face of wall including 100mm dia. C.I. plug, bend and necessary pipe connection, etc complete. As directed by Engineer in charge. (Jaquar / Equivalent make Confirming Green Bldg Certificate) Ground Floor
Providing and fixing Orissa Pan First Floor
Providing and fixing Orissa Pan Second Floor
Providing and fixing Orissa Pan Third Floor
Providing and fixing Orissa Pan Fourth Floor
Providing and fixing Orissa Pan Fifth Floor
Providing and fixing white Opal series European type wall-hung, of size 400mm x 370mm x 575mm with approved make flush valve including soil pipe, vent pipe upto outside face of wall, 100mm dia C.I. plug bend inlet pipe all fittings, cutting & making good walls, floors etc as directed by Engineer in charge. (Jaquar / Equivalent make Confirming Green Bldg Certificate) Ground Floor
Providing and fixing white Opal series European type wall-hung First Floor
Providing and fixing white Opal series European type wall-hung Second Floor
Providing and fixing white Opal series European type wall-hung Third Floor
Providing and fixing white Opal series European type wall-hung Fourth Floor
Providing and fixing white Opal series European type wall-hung Fifth Floor
Providing and fixing white glazed urinal of size 710x460x300mm with sensotronic concealed type flushing valve for urinal with complete kit having fittings, inlet pipe with stop tap, brackets for fixing the cistern, 32mm diameter P.V.C. flush pipe with fitting and flushing arrangement including lead soil pipe, lead trap & soil pipe connection upto the outside face of wall etc complete. (Jaquar / Equivalent make Confirming Green Bldg Certificate) Ground Floor
Providing and fixing white glazed urinal First Floor
Providing and fixing white glazed urinal Second Floor
Providing and fixing white glazed urinal Third Floor
Providing and fixing white glazed urinal Fourth Floor
Providing and fixing white glazed urinal Fifth Floor
Providing and fixing 75 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete Basement Floor
Providing and fixing 75 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe Ground Floor
Providing and fixing 75 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe First Floor
Providing and fixing 75 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe Second Floor
Providing and fixing 75 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe Third Floor
Providing and fixing 75 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe Fourth Floor
Providing and fixing 75 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe Fifth Floor
Providing and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. Basement Floor
Providing and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe Ground Floor
Providing and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe First Floor
Providing and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe Second Floor
Providing and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe Third Floor
Providing and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe Fourth Floor
Providing and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe Fifth Floor
Providing and fixing H.D.P container Syntex or alike one piece moulded water tank made out of low density polythyler and built corrugation including of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow of all tanks capacity above 1000 to 20,000 litres Sixth Floor
Providing and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Basement Floor
Providing and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe Ground Floor
Providing and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe First Floor
Providing and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe Second Floor
Providing and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe Third Floor
Providing and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe Fourth Floor
Providing and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe Fifth Floor
Providing and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Basement Floor
Providing and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe Ground Floor
Providing and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe First Floor
Providing and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe Second Floor
Providing and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe Third Floor
Providing and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe Fourth Floor
Providing and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe Fifth Floor
Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Basement Floor
Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe Ground Floor
Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe First Floor
Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe Second Floor
Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe Third Floor
Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe Fourth Floor
Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe Fifth Floor
Providing and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Basement Floor
Providing and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe Ground Floor
Providing and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe First Floor
Providing and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe Second Floor
Providing and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe Third Floor
Providing and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe Fourth Floor
Providing and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe Fifth Floor
Providing and fixing on walls /ceiling/ floor 40 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Basement Floor
Providing and fixing on walls /ceiling/ floor 40 mm dia. CPVC pipe Ground Floor
Providing and fixing on walls /ceiling/ floor 40 mm dia. CPVC pipe First Floor
Providing and fixing on walls /ceiling/ floor 40 mm dia. CPVC pipe Second Floor
Providing and fixing on walls /ceiling/ floor 40 mm dia. CPVC pipe Third Floor
Providing and fixing on walls /ceiling/ floor 40 mm dia. CPVC pipe Fourth Floor
Providing and fixing on walls /ceiling/ floor 40 mm dia. CPVC pipe Fifth Floor
Providing and fixing on walls/ ceiling/ floor 50 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Basement Floor
Providing and fixing on walls/ ceiling/ floor 50 mm dia. CPVC pipe Ground Floor
Providing and fixing on walls/ ceiling/ floor 50 mm dia. CPVC pipe First Floor
Providing and fixing on walls/ ceiling/ floor 50 mm dia. CPVC pipe Second Floor
Providing and fixing on walls/ ceiling/ floor 50 mm dia. CPVC pipe Third Floor
Providing and fixing on walls/ ceiling/ floor 50 mm dia. CPVC pipe Fourth Floor
Providing and fixing on walls/ ceiling/ floor 50 mm dia. CPVC pipe Fifth Floor
Providing and fixing 15 cm rigid PVC Nahani trap including PVC grating ,bend,connectingpiece of UPVC pipe up to the outside face of wall ,making the good damaged surface and testing etc. complete ( Prior approval of sample and brand by Ex. Engr. is necessary before use) Ground Floor
Providing and fixing 15 cm rigid PVC Nahani trap First Floor
Providing and fixing 15 cm rigid PVC Nahani trap Second Floor
Providing and fixing 15 cm rigid PVC Nahani trap Third Floor
Providing and fixing 15 cm rigid PVC Nahani trap Fourth Floor
Providing and fixing 15 cm rigid PVC Nahani trap Fifth Floor
Providing and fixing P.V.C. Rain water pipes of 160mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. Basement Floor
Providing and fixing P.V.C. Rain water pipes of 160mm outer diameter Ground Floor
Providing and fixing P.V.C. Rain water pipes of 160mm outer diameter First Floor
Providing and fixing P.V.C. Rain water pipes of 160mm outer diameter Second Floor
Providing and fixing P.V.C. Rain water pipes of 160mm outer diameter Third Floor
Providing and fixing P.V.C. Rain water pipes of 160mm outer diameter Fourth Floor
Providing and fixing P.V.C. Rain water pipes of 160mm outer diameter Fifth Floor
Providing and laying in trenches 15 mm dai. CPVC pipe including necessary excavation, fittings. Refilling trenches etc. complete Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Basement Floor
Providing and laying in trenches 15 mm dai. CPVC pipe Ground Floor
Providing and laying in trenches 15 mm dai. CPVC pipe First Floor
Providing and laying in trenches 15 mm dai. CPVC pipe Second Floor
Providing and laying in trenches 15 mm dai. CPVC pipe Third Floor
Providing and laying in trenches 15 mm dai. CPVC pipe Fourth Floor
Providing and laying in trenches 15 mm dai. CPVC pipe Fifth Floor
Providing and laying in trenches 20 mm dai. CPVC pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Basement Floor
Providing and laying in trenches 20 mm dai. CPVC pipe Ground Floor
Providing and laying in trenches 20 mm dai. CPVC pipe First Floor
Providing and laying in trenches 20 mm dai. CPVC pipe Second Floor
Providing and laying in trenches 20 mm dai. CPVC pipe Third Floor
Providing and laying in trenches 20 mm dai. CPVC pipe Fourth Floor
Providing and laying in trenches 20 mm dai. CPVC pipe Fifth Floor
Providing and laying in trenches 25 mm dai. CPVC pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Basement Floor
Providing and laying in trenches 25 mm dai. CPVC pipe Ground Floor
Providing and laying in trenches 25 mm dai. CPVC pipe First Floor
Providing and laying in trenches 25 mm dai. CPVC pipe Second Floor
Providing and laying in trenches 25 mm dai. CPVC pipe Third Floor
Providing and laying in trenches 25 mm dai. CPVC pipe Fourth Floor
Providing and laying in trenches 25 mm dai. CPVC pipe Fifth Floor
Providing and laying in trenches 32 mm dai. CPVC pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Basement Floor
Providing and laying in trenches 32 mm dai. CPVC pipe Ground Floor
Providing and laying in trenches 32 mm dai. CPVC pipe First Floor
Providing and laying in trenches 32 mm dai. CPVC pipe Second Floor
Providing and laying in trenches 32 mm dai. CPVC pipe Third Floor
Providing and laying in trenches 32 mm dai. CPVC pipe Fourth Floor
Providing and laying in trenches 32 mm dai. CPVC pipe Fifth Floor
Providing and laying in trenches 40mm dai. CPVC pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Basement Floor
Providing and laying in trenches 40mm dai. CPVC pipe Ground Floor
Providing and laying in trenches 40mm dai. CPVC pipe First Floor
Providing and laying in trenches 40mm dai. CPVC pipe Second Floor
Providing and laying in trenches 40mm dai. CPVC pipe Third Floor
Providing and laying in trenches 40mm dai. CPVC pipe Fourth Floor
Providing and laying in trenches 40mm dai. CPVC pipe Fifth Floor
Providing and laying in trenches 50mm dai. CPVC pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Basement Floor
Providing and laying in trenches 50mm dai. CPVC pipe Ground Floor
Providing and laying in trenches 50mm dai. CPVC pipe First Floor
Providing and laying in trenches 50mm dai. CPVC pipe Second Floor
Providing and laying in trenches 50mm dai. CPVC pipe Third Floor
Providing and laying in trenches 50mm dai. CPVC pipe Fourth Floor
Providing and laying in trenches 50mm dai. CPVC pipe Fifth Floor
Providing and fixing in position UPVC ultra violet stabilized 110 mm outer diameter cowl dome confirming to I.S.-4985 including making joints with solvent cement etc. complete Ground Floor
Providing and fixing in position UPVC ultra violet stabilized 110 mm outer diameter cowl dome Terrace Floor
Providing and fixing Glass self 125 mm wide and 600 mm long with necessary chromium plated brackets providingT.W.gutties etc. complete Ground Floor
Providing and fixing Glass self 125 mm wide and 600 mm long with necessary chromium plated brackets First Floor
Providing and fixing Glass self 125 mm wide and 600 mm long with necessary chromium plated brackets Second Floor
Providing and fixing Glass self 125 mm wide and 600 mm long with necessary chromium plated brackets Third Floor
Providing and fixing Glass self 125 mm wide and 600 mm long with necessary chromium plated brackets Fourth Floor
Providing and fixing Glass self 125 mm wide and 600 mm long with necessary chromium plated brackets Fifth Floor
Supplying and erecting Automatic Sanitizer Dispenser body size (450mmx300mmx220mm), Wall Mounted With 5Liters Capacity of Sanitization Liquid Container and Operation type (Automatic / Touchless), Sensor type motions senser, Voltage-220V,50Hz, for power consumtion(idel mode)-<3VA and (operation mode) -25A, (MOC-Acrylonitrile butadiene styrene (ABS), Polypropylene (PP), brass), with 6 months waranty against manufacturing defects. Basement Floor
Supplying and erecting Automatic Sanitizer Dispenser Ground Floor
Supplying and erecting Automatic Sanitizer Dispenser First Floor
Supplying and erecting Automatic Sanitizer Dispenser Second Floor
Supplying and erecting Automatic Sanitizer Dispenser Third Floor
Supplying and erecting Automatic Sanitizer Dispenser Fourth Floor
Supplying and erecting Automatic Sanitizer Dispenser Fifth Floor
Providing and fixing in position alluminium strips of size 50mm x 3mm for nosing the steps including fixing with screws and raval plugs, bending and cutting to the required shape and size, finishing with paint, necessary mortar bedding of 1:3 cement mortar to get exact line and level including watering and curing etc.complete Basement Floor
Providing and fixing in position alluminium strips Ground Floor
Providing and fixing in position alluminium strips First Floor
Providing and fixing in position alluminium strips Second Floor
Providing and fixing in position alluminium strips Third Floor
Providing and fixing in position alluminium strips Fourth Floor
Providing and fixing in position alluminium strips Fifth Floor
Providing and fixing lioghtening conductor system comprising of erecting Air-Termination consisting of tubular copper rod of 25mm dia. 1.2 mm thick with multiple points head 1.2 mt. long ( Heavy Duty) welded or clamped to G.I. pipe pole B grade 50 mm diaof requiired length with M.S. round bnase plate 25 Cm diam and 10mm thick at bottom embeded in cement concrete 1:3:6 dfoundation of size 45 cm diam x 45 cm Height and providing earthing with copper earth plate of size 60 x 60 x 0.3 cms with cadmium plated nut bolts to fix earthing strip burried in specially prepared earth pits 1.5 metre below ground level with 40Kilogramcharcoal and salt with altemate layers of charcoal and salt and G.I.pipe 40mm dia 2 meter length burried in earthe upto earthling plate remining portion above ground level for watering and refilling comcpete Note- Copper strip fropm lightening conductor is not considered in this item. Basement Floor
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorophyrifos per square meter of surface area covering 10 years guarantee on bond paper. Basement Floor
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) treatment by treating the backfill in immediate contact with foundation at the rate of 5 litres of emulsion concentrate of 1.0 percent of clorophyrifos per square metre of vertical surface area covering 10 years guarantee on bond paper. Basement Floor
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 1.0 percent of clorophyrifos per square metre of surface area covering ten years guarantee on bond paper. Basement Floor
Providing and fixing 90 cm x 60 cm Granite plate engraving 10 cm. height letter, figures including painting the lefters/figures with approved colour and shade complete Basement Floor
Supply, fixing and installation of 4mm thick Aluminium Composite Panel (ACP) of approved colour for external cladding in combination of solid and metallic colours, including all necessary Framework, support and complete weather sealing as per architectural drawing. The Aluminium Composite Panel (ACP) should be made out of thermoplastic core of low-density polyethylene LDPE (100% virgin mix), sandwiched between two aluminium sheets of ALLOY GRADE- 5000 series, each Nost less than 0.50 mm thick, total thickness of aluminium composite panels Nost to be less than 4 mm, the exposed surface thereof shall have Stove lacquered finishing coat Nost less than (26 + - 2) micron (containing minimum 70% kynar 500 based PVDF) of colour and shade as per architectural design. The inside surface (facing the building exterior surface)shall have polyster based powder coating Nost less than 25 Micron with protective peel-off foil on the exterior face (peel off film will in Nos case leave any adhesive mark over the composite panel surface after it is peeled off). The supporting framework shall be made out of 50 mm X25mm X 3mm thick Aluminium section to be spaced horizontally and vertically for fixing of panel of size 900 mm X 1200 mm and fixed to the building structure as per design through 50mm X50mm X5 mm MS angle clamps prefixed to masonry or slab, columns with Hilti make anchor fastener screws. The fixing of panel to be done with the help of VHB tapes and screws and all the sealing of joints to be done with weather sealent Silicon as directed by Engineer-in-charge. (Prior permission of S.E. is necessary before inclusion of this item in estimate) Spec. Nos. As directed by Engineer in charge. Basement Floor
Providing and fixing sky light in R.C.C. roof including frame made of M.S. angle 50 x 50 x 6 mm with hold fast, sheet glass 12 mm thick, Chicken mesh 24 gauge with all accessories and required fixtures and fastening fitting including painting etc. complete. Basement Floor
Supply and Installation of translucent roof with DPI Flux standing seam multicell polycarbonate panel system. The system with complete assembly of co extruded UV protected multicell panels incorporated into a complete system. Co-extruded UV protected polycarbonate panel system of min 12 mm thick of 900 mm (min.) width with angular daylighting concept. Panels shall have minimum six layers with truss bridge design for higher flexibility & strength. Panels with all fixing accessories to ensure best performance for wind uplift, vibration, oil canning and visual appearance. Panels shall be manufactured with vertical standing seam at both sides of the panel. Panels shall be fixed on Purlin with snap on connectors with double tooth grip lock locking mechanism and will be secured on MS structure (will be paid Separately) with 3 numbers self-drilling screws & trapezoid SS fasteners holding the base of the standing seam offering best stability having a pull-out load of min. 7000N (7KN) tested as per ISO 6892:1998 and IS 1608: 2005, as per design requirement. Panels must satisfy Dart drop impact test as per IS 14443-97 shall show Nos sign of breakage on Polycarbonate sheets which have been exposed to UV for a min. of 500 Hours as per ASTM G 155. Panels shall Nost have Yellowness Index as per ASTM D 1925 of 15 units when tested on a sample exposed to UV for 500 Hours as per ASTM G 155. U value shall Nost be more than 1.6 W/m2K as per EN ISO 10077-2:2018. Panel shall be with Spec. Nos. As directed by Engineer in charge. Terrace Floor
Providing soak pit of size 120cm x 120cm x 120cm including excavating and filling with brick-bats. Basement Floor
RWH - Shallow Percolation Pit providing, constructing 2.0m deep shallow depth percolation pit comprising of 1.0m dia pre-cast RCC rings, 300mm thick side filling around outside of RCC rings (annular space) with 40mm size boulders including filling of percolation pit up to 0.5m depth (from bottom up) with 25-75mm clean washed gravels followed by 0.5m depth of 10-25mm of clean washed stones followed by 0.5m of washed river fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) including netlon mesh between each gravel/fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) media layer including covering with RCC slab, manhole frame & cover, PVC rungs etc. including arrangement for inlet & outlet pipe, excavation & backfilling as shown in the drawing. The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing, technical specification and direction of the Engineer in charge Basement Floor
Boring/drilling bore well of 300mm dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machinery required for the job, all complete as per direction of Engineer in charge, upto 90m depth below ground level. Basement Floor
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well-casing pipe of 150mm dia, conforming to IS:12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per the direction of Engineer in charge. Ground Floor
Providing and installing bio digester unit based on DRDO technology made of fibre reinforced plastic (FRP) having composition and following technical specifications and including necessary pipe and accessories up to 3 meter length, excluding the necessary excavation for installing the bio digester. Percentage of fibre glass (glass content in fibre glass should be minimum 30%): -33.33% Percentage of polyester resin: - 66.67% Water absorption (as per ASTM):-0.30% Flammability as per ASTM Tensile strength:-115 MPA Specific Gravity at 25 degree centigrade 1.45 Izod impact strength:-65KJ/M2 Heat defection/distort temperature:-65deg C Corrosion resistance (Non Corrosive) fitted with Inlet pipe size rigid PVC: -100mm Outlet pipe size rigid PVC:-80mm Gas outlet rigid PVC with Valve: 20mm Bacteria immobilization PVC mattes (on all partition) With DRDO TOT licensee and latest batch certificate(month & year of supply) and capacity as below c) Up to 25 user size (1.5mx1.0mx1.0m), Capacity of biodgester:-1500 liters, Area of top, bottom and side walls:- 8 sq.m, Area of partition walls: 2 sq.m, Total weight of frp: - 82.80 Kilogram, Bacteria iNosculums quantity: - 600 liters, Minimum thickness of side walls / top and bottom: 5mm, Number of inside partitions: - 3, Minimum thickness of partition wall: 3mm Basement Floor
d) Up to 40 user size (2.0mx1.0mx1.0m), Capacity of biodgester:-2000 liters, Area of top, bottom and side walls: - 10 sq.m, Area of partition walls: 3 sq.m, Total weight of frp: - 106.20 Kilogram, Bacteria iNosculums quantity: - 600 liters, Minimum thickness of side walls / top and bottom: 5mm, Number of inside partitions: - 3, Minimum thickness of partition wall: 3mm Basement Floor
Providing and Fixing of Mineral Fibre Board Acoustical Suspended Ceiling System with ultima (Bevelled Tegular) Edge Tiles of size 15mm Exposed GRID. The tiles should have Humidity Resistance (RH) of 99%, NRC 0.7, Light Reflectance 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600 x 600 x 20mm , suitable for Green Building application, with Recycled content of 32%. The tile shall be laid on precoated G.I.channel on XL2 Clip having a web height of 32 mm with 15 mm wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm and 600 mm Cross Tees with a web height of 32 mm and a load carrying capacity of 7.7 Kilograms/M2 and minimum pull out strength of 100 Kilograms.. The T Sections have a Galvanizing of 90 grams per M2 and need to be installed with Suspension system. The Tile and Grid system used together should carry a 10 year warranty. products approved as per GRIHA and BS 476 etc. complete. Ground Floor
Providing and Fixing of Mineral Fibre Board Acoustical Suspended Ceiling First Floor
Providing and Fixing of Mineral Fibre Board Acoustical Suspended Ceiling Second Floor
Providing and Fixing of Mineral Fibre Board Acoustical Suspended Ceiling Third Floor
Providing and Fixing of Mineral Fibre Board Acoustical Suspended Ceiling Fourth Floor
Providing and Fixing of Mineral Fibre Board Acoustical Suspended Ceiling Fifth Floor
Providing & Fixing in position Acoustical Doors along with 150 x 150 mm teak wood frame, doors made from 50mm Teak wood frame 600 x600 c to c filled with 1000 Gsm synthetic wool 50mm thick and 3mm Tecsound from both sides, 12mm waterproof ply & veneer from both sides , including 150mm heavy duty SS hinges (Geze / Dorma or eq.) 4 no each leaf, with Door-closer (Dorma / Geze or eq.) including cost of required Cut-Outs, decorative mouldings / finishing-items / melamine polish & Scaffolding as per Architectural & Acoustical Design & Instructions & Complete in all aspects .including all materials labour,finishing etc complete First Floor
Providing & Fixing in position Acoustical Doors Second Floor
Providing & Fixing in position Acoustical Doors Fifth Floor
Providing the consultancy services for GRIHA certification of the building, including all related expenses in achieving Green certification, including all lead, lift and taxes; excluding GST, including conducting all awareness program during inception till the receipt of GRIHA certification and even during 2 years of defect liability period; including the fees for training programme, excluding the fee for statutory requirements and GRIHA certification which will be paid by P.W. Dept. & Site visit piad by the contractor , including all related to the achivement of the GRIHA certification etc. complete and as directed by engineer-in-charge. (For total built up aera of project )
Engaged Computer Opreter for project work etc complete
Engaged Assistant for project work
Providing and fixing 20 to 25 mm thick rough shahabad box type waterproofing for basement or underground floor on a base of Cement concrete 1:3:6, including sub base of 2.50 centimeter thick Cement mortar 1:3 with conceal, secrete (RMW), Algae proof or other alike waterproofing liquids, raking of joints upto 35 mm depth, filling the joints with 6 mm size crushed metal, hand grouting with cement slurry, curing and cleaning, with 7 years guarantee on court fee stamp of Rs. 100/- with ponding test etc complete. (excluding Cement concrete 1:3:6 base concrete )
Providing and applying three coats of water proof cement paint of approved manufacture and of approved colour to new plastered surfaces including scaffolding if necessary, cleaning and preparing the surface, watering for two days etc. complete.
Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9 mm with lock plate of 3.15 mm thickness reinforced with 35 x 35 x 5 mm angle section fitted with sliding bolts and handles for both sides, deep M.S. channel section of depth and thickness not less than 65 mm and 3.15 mm respectively with hold fast arrangements, M.S. Bracket plate 300 x 300 x 3.15 mm minimum size and shape with square bar, suspension shaft of minimum 32 mm diameter, hood cover of M.S. sheet not less than 0.9 mm thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high grade cast iron or mild steel and one coat of red lead primer etc. complete. (I.S. 62481979) (With mechanical gear)
Providing and Fixing Rollar Blinds AMI Make or approved make & shade of 38mm round Aluminium channel with Blackout fabric & telting with chain (Ball) system with all necessary fixtures and fitting etc. complete. (Sample to be final by Engineer In-charge prior execution of work) Ground floor
Providing and Roller blinds First Floor
Providing and Roller blinds Second Floor
Providing and Roller blinds Third Floor
Providing and Roller blinds Fourth Floor
Providing and Roller blinds Fifth Floor
Pedestal Unit @ 420Lx450Dx650HT Providing & Fixing of PEDESTAL @ 420Lx450Dx650HT :- To be made out of Complete Membrane consist of three Drawers as per drawing. Ground floor
Providing & Fixing of PEDESTAL First Floor
Providing & Fixing of PEDESTAL Second Floor
Providing & Fixing of PEDESTAL Third Floor
Providing & Fixing of PEDESTAL Fourth Floor
Providing & Fixing of PEDESTAL Fifth Floor
Credestal @ 1200Lx450Lx650HT Providing & Fixing of LOW HEIGHT CREDESTAL @ 1200L X 450D X 650H :- To be made out of Membrane Finish ( 2 Openable Shutter & 3 Drawer Pedestal in between )as per drawing. Ground floor
Providing & Fixing of LOW HEIGHT CREDESTAL First Floor
Providing & Fixing of LOW HEIGHT CREDESTAL Second Floor
Providing & Fixing of LOW HEIGHT CREDESTAL Third Floor
Providing & Fixing of LOW HEIGHT CREDESTAL Fourth Floor
Providing & Fixing of LOW HEIGHT CREDESTAL Fifth Floor
3 DRAWER PEDESTAL UNIT @ 392L x 450D x 680Ht. mm. 3 DRAWER PEDESTAL UNIT having overall size 392L x 450D x 680Ht. mm. with central lock and key. 3 Drawers and body are complete metal with powder coat finish, facia in 18 mm prelaminated particle board. Ground floor
3 DRAWER PEDESTAL UNIT First Floor
3 DRAWER PEDESTAL UNIT Second Floor
3 DRAWER PEDESTAL UNIT Third Floor
3 DRAWER PEDESTAL UNIT Fourth Floor
3 DRAWER PEDESTAL UNIT Fifth Floor
Low Height Openable Storage @ 900Lx450x750HT Providing and fixing Openable Steel Storage of 900 x 450 x 750Ht, with 2 adjustable shelves, Complete body & shutter made in 0.8 mm thick & Top in 2 mm thick CRCA, 2 Shutter to be mounted with the help of cup hinges, and 4 adjustable levelers, enitre storage in powder coated finish with 60 to 80 microns. with 25 mm. thk additional Top on top of storage as as per drawing Ground floor
Providing and fixing Openable Steel Storage First Floor
Providing and fixing Openable Steel Storage Second Floor
Providing and fixing Openable Steel Storage Third Floor
Providing and fixing Openable Steel Storage Fourth Floor
Providing and fixing Openable Steel Storage Fifth Floor
Executive Table @ 2250Lx2100Dx750HT including Low Height Credestal @ 1200Lx450Dx650HT Providing & Fixing of Table @ 2250Lx2100Dx750HT TOP & GABLE END to be made of Membrane finish with soft water fall edges & curved panel & Decorated Anodized section MODESTY PANEL to be made of 18 mm thick Prelaminated particle board with PVC edge band. INCLUDING CREDESTAL @ 1200L X 450D X 650H :- To be made out of Membrane Finish ( 2 Openable Shutter & 3 Drawer Pedestal in between ) as per drawing. Ground floor
Providing & Fixing of Executive Table First Floor
Providing & Fixing of Executive Table Second Floor
Providing & Fixing of Executive Table Third Floor
Providing & Fixing of Executive Table Fourth Floor
Providing & Fixing of Executive Table Fifth Floor
Conference Table @ 3600Lx1400Dx750HT Providing & Fixing of Main Table @ 3600Lx1400Dx750HT - made up of 18+18mm Thick MDF top with PVC Membrane finish and waterfall edge profile. Aluminium Anodizied finish beeding of 4mm thich is running all over the table top edge. Gable ends is Aerofoiled Shape with front edges in PVC Membrane finish and rest in Prelaminated MDF with batton structure. Gable ends should be hollow from inside for the provision of passing electrical and Data wiring. , MODESTY PANEL:- to be made of 18 mm thick Prelaminated particle board with PVC edge band Access Flap:- For Wire manager 2 Nos. Ground floor
Providing & Fixing of Conference Main Table First Floor
Providing & Fixing of Conference Main Table Second Floor
Providing & Fixing of Conference Main Table Third Floor
Providing & Fixing of Conference Main Table Fourth Floor
Providing & Fixing of Conference Main Table Fifth Floor
Double Faced Mobile Unit for Compactor 2150mmH x 1830mmW x 900mmD Providing and fixing Double Faced Mobile Unit for Compactor 2150mmH x 1830mmW x 900mmD - BASE FRAME : Base Frame shall be fabricated in channel Type from minimum 2.5 mm thick MS Sheet Size of Channel 25mm x 100mm x 45mm. GUIDE RAILS : The guide rails shall be made out of 28mm Bright bar placed on 1.2 mm thick M.S. Plate which will be above the floor and are as per the international standard of safety. SUPER STRUCTURE : Super structure of the Mobile storage system will consist of knock down type panels. All the components such as shelves, front panel, end panel, vertical rear panel, central partition etc. Will act as an integral member of the Unit. SHELVES : Shelves made of 22SWG thick Prime Quality C.R.C.A. having 10 folds each will be provided each designed to carry a U.D.L. of 70 Kilograms. VERTICAL PANEL : Vertical panel consists of the front, Centre & rear panel shall be made out of 20SWG thick C.R.C.A. Prime quality Mild Steel & designed to take the load of shelves. DRIVE COVER PANEL : Made out of 22SWG thick C. R.C. A. prime quality Steel to cover the entire drive mechanism. CENTRE Ground floor
Double Faced Mobile Unit for Compactor First Floor
Double Faced Mobile Unit for Compactor Second Floor
Double Faced Mobile Unit for Compactor Third Floor
Double Faced Mobile Unit for Compactor Fourth Floor
Double Faced Mobile Unit for Compactor Fifth Floor
Book Case with Glass Shutter @ 825Lx300Dx1650HT Providing & Fixing of Book Case with Glass Shutter @ 825Lx300Dx1650HT:- To be made out of complete body & in 0.7mm thick CRCA & Shutter in 1.2mm thick CRCA with glass pannel in Powder coating finish as per drawing. Ground floor
Providing & Fixing of Book Case with Glass Shutter First Floor
Providing & Fixing of Book Case with Glass Shutter Second Floor
Providing & Fixing of Book Case with Glass Shutter Third Floor
Providing & Fixing of Book Case with Glass Shutter Fourth Floor
Providing & Fixing of Book Case with Glass Shutter Fifth Floor
Providing & Arrangemnt of High Back, Synchronized Mechanism with Multiple Locking, Adjustable Armrest, Gaslift for Seat height adjustment, Standard 5-prong P/Nylon Base with Leatherite Upholstery First floor
Providing & Arrangemnt of High Back, Synchronized Mechanism Second Floor
Providing & Arrangemnt of High Back, Synchronized Mechanism Third Floor
Providing & Arrangemnt of High Back, Synchronized Mechanism Fourth Floor
Providing & Arrangemnt of High Back, Synchronized Mechanism Fifth Floor
Providing & Arrangemnt of High Back Chair - TILT MECHANISM WITH MULTILOCKING, HIGH DENSITY CUSHION ON SEAT COMPOSITE LEATHER WITH METALLIC SILVER FINISH BASE AND ARMS WITH P.U.CASTORS GASLIFT FOR HEIGHT ADJUSTMENT. Ground floor
Providing & Arrangemnt of High Back Chair First Floor
Providing & Arrangemnt of High Back Chair Second Floor
Providing & Arrangemnt of High Back Chair Third Floor
Providing & Arrangemnt of High Back Chair Fourth Floor
Providing & Arrangemnt of High Back Chair Fifth Floor
Providing & Arrangemnt of MId Back, Normal Syncro Mechanism , Fixed Armrest , Gaslift for Seat height adjustment, Standard 5-prong/Nylon Base with Leather Upholstery Ground floor
Providing & Arrangemnt of MId Back, Normal Syncro Mechanism First Floor
Providing & Arrangemnt of MId Back, Normal Syncro Mechanism Second Floor
Providing & Arrangemnt of MId Back, Normal Syncro Mechanism Third Floor
Providing & Arrangemnt of MId Back, Normal Syncro Mechanism Fourth Floor
Providing & Arrangemnt of MId Back, Normal Syncro Mechanism Fifth Floor
Public Seating Chair. - 3 Seater Providing and Fixing 3 seater Public seating chair made of complete metal with Legs in Crome finish and seates in silver powder coating finish. Ground floor
Providing and Fixing 3 seater Public seating chair First Floor
Providing and Fixing 3 seater Public seating chair Second Floor
Providing and Fixing 3 seater Public seating chair Third Floor
Providing and Fixing 3 seater Public seating chair Fourth Floor
Providing and Fixing 3 seater Public seating chair Fifth Floor
Alluminium foldable ladder for store Providing & Fixing Foldable Alluminum Ladder 1500 mm. Ht. Ground floor
Providing & Fixing Foldable Alluminum Ladder First Floor
Providing & Fixing Foldable Alluminum Ladder Second Floor
Providing & Fixing Foldable Alluminum Ladder Third Floor
Providing & Fixing Foldable Alluminum Ladder Fourth Floor
Providing & Fixing Foldable Alluminum Ladder Fifth Floor
Sofa Set 3+1+1 Providing & fixing Sofa Set 3+1+1 Brown and Cream leather DIMENSION Length: 182.5 (cms) Breadth (cms): 100 (cms)Height (cms): 100 (cms) Weight (Kilograms): 66 (Kilogram) Seating Capacity: Five Seat Ground floor
Providing & fixing Sofa Set First Floor
Providing & fixing Sofa Set Second Floor
Providing & fixing Sofa Set Third Floor
Providing & fixing Sofa Set Fourth Floor
Providing & fixing Sofa Set Fifth Floor
Free Standing Table @ 1200Lx600Dx750HT Providing and fixing Table of Size 1200 x 600 x 750 mm. Top: made from 25 mm Prelaminated Particle board. All edges are covered by 2 mm. Thk. PVC edge bands glued by hot melt glue applied by auto edge banding machine. Legs : C Shape made from CRCA Sheet with Powder Coat finish. Modesty panel : Made from 18mm both side prelaminated particle boards.All edges are covered by 0.8mm PVC edge bands glued by hot melt glue applied by auto edge banding machine.KEYBOARD TRAY ( WITHOUT MOUSE TRAY ) :- Metal Powder Coated - Black Color, CPU TROLLEY :- Metal Powder Coated - Black Color, 3 DRAWER PEDESTAL UNIT having overall size 392L x 450D x 680Ht. mm. with central lock and key. Drawers and body are complete metal with powder coat finish, facia in 18 mm prelaminated particle board, Ground floor
Providing and fixing Table First Floor
Providing and fixing Table Second Floor
Providing and fixing Table Third Floor
Providing and fixing Table Fourth Floor
Providing and fixing Table Fifth Floor
12 Seater Reading Table for Library @ 3600Lx1200Dx750HT Providing and Fixing 12 Seater Reading Table for Liberary @ 3600Lx1200Dx750HT Top: made from 25 mm Prelaminated Particle board. All edges are covered by 2 mm. Thk. PVC edge bands glued by hot melt glue applied by auto edge banding machine. Gable Ends : made from 25 mm Prelaminated Particle board. All edges are covered by 2 mm. Thk. PVC edge bands glued by hot melt glue applied by auto edge banding machine. Modesty panel : Made from 18mm both side prelaminated particle boards.All edges are covered by 0.8mm PVC edge bands glued by hot melt glue applied by auto edge banding machine. Ground floor
Providing and Fixing 12 Seater Reading Table Fifth Floor
Tea Table 900mm X 750mm X 450mm for m.s. ante chamber Providing And Fixing Of Tea Table 900mm X 750mm X 450mm With 12mm Thick Colour Eitched Tempered Glass With Bevelled Drawing Made Out Of 18mm Thick Waterproofing Ply. The Outer Laces To Be Finished With High Quality 4 Mm Thik Veneer Or 1 Mm Thik Mica Etc. Ground floor
Tea Table 900mm X 750mm X 450mm for m.s. ante chamber Fifth Floor
Providing & Fixing in position, 12mm wp Ply wood & 1.5mm laminate panels above the fabricated frame on one side , as per Architectural & Acoustical Design & Instructions & Complete in all aspects. including all materials labour,finishing etc complete First floor
Providing & Fixing in position, 12mm wp Ply wood & 1.5mm laminate panels Second Floor
Providing & Fixing in position, 12mm wp Ply wood & 1.5mm laminate panels Third Floor
Providing & Fixing in position, 12mm wp Ply wood & 1.5mm laminate panels Fourth Floor
Providing & Fixing in position, 12mm wp Ply wood & 1.5mm laminate panels Fifth Floor
Kitchen Trolley Providing and Fixing stainless steel kitchen trolley of overall 26 " height and 22" depth,supported on aluminium pipes ,trolley basket made out of 5 mm stainless steel rod fitted on telescopic channel of size 1.5 " x 20 " x 22 " on both sides of trolley of 12 " or above size, panel having 40Kilogramload bearing capacity of trolley made out of 20 mm PUC coated plywood and colour combination as directed by E-I-C.Inner side of panel covered by white mica ,100 mm s.s. decorative handle.(The width and height of individual compartments shall be kept as directed by Engineer-in-charge)
Providing & Fixing Wooden Dias of 45cm Ht Of Superiour indian Teak Wood As per Detailed Drawing Supported Vertical Struts Of Size 75x75mm & fixing 35mm thick Teak Wood planks at top floor including all fixtures & fastnings etc.comp Ground floor
Providing & Fixing Wooden Dias First Floor
Providing & Fixing Wooden Dias Second Floor
Providing & Fixing Wooden Dias Third Floor
Providing & Fixing Wooden Dias Fourth Floor
Providing & Fixing Wooden Dias Fifth Floor
Providing and fixing Judge'sPartition for Dias with side gates in Court Hall of size 4.26 x 1.65 of 18 millimetre thick commercial ply and 12 millimetre thick commercial ply with 1 millimetre laminate fitted on exterior surfaces and teak wood balusters and teak wood ball for decoration, teak wood balusters 0.07 x 0.07 x 0.60 meter and moulding on railing top polished in mirror finish melamine polish including surface termite treatment to all plywood, necessary hardware, labour etc. complete, as per design and drawing and instructions of Engineer in charge. Ground floor
Providing and fixing Judge'sPartition for Dias with side gates in Court Hall First Floor
Providing and fixing Judge'sPartition for Dias with side gates in Court Hall Second Floor
Providing and fixing Judge'sPartition for Dias with side gates in Court Hall Third Floor
Providing and fixing Judge'sPartition for Dias with side gates in Court Hall Fourth Floor
Providing and fixing Judge'sPartition for Dias with side gates in Court Hall Fifth Floor
Providing & Fixing Wooden Steps of rise 15 cm and 30 tread Of Superiour indian Teak Wood As per Detailed Drawing Supported Vertical Struts Of Size 75x75mm & fixing 35mm thick Teak Wood planks at top floor including all fixtures & fastnings etc.comp Ground floor
Providing & Fixing Wooden Steps of rise First Floor
Providing & Fixing Wooden Steps of rise Second Floor
Providing & Fixing Wooden Steps of rise Third Floor
Providing & Fixing Wooden Steps of rise Fourth Floor
Providing & Fixing Wooden Steps of rise Fifth Floor
Design, supply, fabrication and fixing acrylic multilingual Braille (raised dots) signboards of size 6"x 9" for room titles, designed as per the drawings issued and having 4mm thick blue acrylic base plate with Upper Case San Serif words made of white acrylic non glare cut out letters of height 15mm raised not less than 0.8mm above base plate and the equivalent word/s written in Hindi with Devnagri non glare acrylic letters of height 15mm raised not less than 0.8mm above base plate. Grade 2/ Grade 1 Braille to be integral with the sign face and be raised 0.5mm above base plate.Each signboard to be fixed as per manufacturers specifications on the wall adjoining the respective room door at a height of 1200mm from FFL and as per the directions by the engineer in charge. Ground floor
Design, supply, fabrication and fixing acrylic multilingual Braille First Floor
Design, supply, fabrication and fixing acrylic multilingual Braille Second Floor
Design, supply, fabrication and fixing acrylic multilingual Braille Third Floor
Design, supply, fabrication and fixing acrylic multilingual Braille Fourth Floor
Design, supply, fabrication and fixing acrylic multilingual Braille Fifth Floor
Supplying Judges Chair Without Rajmudra Ground floor
Supplying Judges Chair Without Rajmudra First Floor
Supplying Judges Chair Without Rajmudra Second Floor
Supplying Judges Chair Without Rajmudra Third Floor
Supplying Judges Chair Without Rajmudra Fourth Floor
Supplying Judges Chair Without Rajmudra Fifth Floor
Supplying CCTW Chair Wooden Seat & Back Ground floor
Supplying CCTW Chair Wooden Seat & Back First Floor
Supplying CCTW Chair Wooden Seat & Back Second Floor
Supplying CCTW Chair Wooden Seat & Back Third Floor
Supplying CCTW Chair Wooden Seat & Back Fourth Floor
Supplying CCTW Chair Wooden Seat & Back Fifth Floor
Add Royalty charges etc complete - Sand
Add Royalty charges etc complete - All other Minerals
Providing testing report from PWD VQC Lab / Govt lab etc complete -Cement Carrying out basic tests on cement for standard consistancy, Fineness, Specific gravity, Setting time (Initial and Final), Compressive strength, Soundness.
Providing testing report from PWD VQC Lab / Govt lab etc complete -Fine Aggregates Carrying out basic tests on Sand for Fineness modulus,Silt and clay content.
Providing testing report from PWD VQC Lab / Govt lab etc complete -Sand Carrying out basic tests on Sand for chloride and sulphate content.
Providing testing report from PWD VQC Lab / Govt lab etc complete -Basic Test of Aggregates Carrying out basic tests on Aggeregates for Water absorption,specific gravity.Impact value,crushing value.
Providing testing report from PWD VQC Lab / Govt lab etc complete - Carrying out basic tests on Aggeregates for Sieve Analysis.
Providing testing report from PWD VQC Lab / Govt lab etc complete -Basic Test of Concrete Carrying out basic tests on Concrete cubes for compressive strength
Providing testing report from PWD VQC Lab / Govt lab etc complete -Concret Mix Design Carrying out basic tests on Concrete for Mix design.
Providing testing report from PWD VQC Lab / Govt lab etc complete -Brick Carrying out basic tests on Bricks for water absorptio,Efflorescence, compressive strength.
Providing testing report from PWD VQC Lab / Govt lab etc complete -Ceramic Tiles / Vitrified Tiles Carrying out basic tests on Vitrified Tiles for water absorption,modulus of rupture
Providing testing report from PWD VQC Lab / Govt lab etc complete - Steel Bar Carrying out basic tests on T.M.T.Steel (Bar testing above 16 mm) for Tensile strength,% Elongation,Yield stress,Weight /m,Bend/rebend test.proof test
Providing testing report from PWD VQC Lab / Govt lab etc complete -Steel bar Carrying out basic tests on T.M.T.Steel (Bar testing upto 16 mm) for Tensile strength,% Elongation,Yield stress,Weight /m,Bend/rebend test.proof test.
Providing testing report from PWD VQC Lab / Govt lab etc complete -Concrete Paving Block Carrying out basic tests on Concrete paving block for Comp.strength, Water absorption,Flexural test,Resistance to wear
Providing testing report from PWD VQC Lab / Govt lab etc complete -Basic Test of Mortar Carrying out basic tests on Mortar for Comp.strength.
Providing testing report from PWD VQC Lab / Govt lab etc complete -Basic Test of Stone / Rubble Carrying out basic tests on stone/rubble for Crushing value/Comp.strength,water absorption and specific gravity
Providing testing report from PWD VQC Lab / Govt lab etc complete -Basic Test of Soil / Murum Carrying out basic tests on soil/Murum for field moisture content
Providing testing report from PWD VQC Lab / Govt lab etc complete -Murum Carrying out basic tests on soil/Murum for liquid limit and plastic limit .
Providing testing report from PWD VQC Lab / Govt lab etc complete -Basic Test of Wood Carrying out basic tests on wood for density and moisture content
Providing testing report from PWD VQC Lab / Govt lab etc complete -Basic Test of Flush Door Carrying out basic tests on flush door for knif test, adhesion test and end immersion
Providing testing report from PWD VQC Lab / Govt lab etc complete -Basic Test of Aluminium Section Carrying out basic tests on aluminium section for thickness, mass per running meter .
Providing testing report from PWD VQC Lab / Govt lab etc complete -Basic Test of G.I. Pipes Carrying out basic tests on G.I.Pipes for wt. per running meter, dia.of pipe and wall thickness of pipe
Supplying & erecting HMS P.V.C. conduit 25 mm. dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
Supplying & laying HMS PVC conduit 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
Supplying & erecting HMS P.V.C. conduit 32 mm. dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
Supplying & laying HMS PVC conduit 32 mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
Supplying and erecting UPVC reinforced flexible conduit 20 mm in dia. conforming to I.S. with required number of couplings, PVC bushes, check nuts etc. complete.
Supplying and erecting HMS PVC conduit 25 mm dia. with PVC accessories on wall /ceiling as per specification No: WG-MA/CON.
Supplying and erecting PVC trunking (PVC casing-n-capping) of size 25 mm with accessories on wall/ceiling as per specification No: WG-MA/CON.
Supplying and erecting PVC trunking (PVC casing-n-capping) of size 32 mm with accessories on wall/ceiling as per specification No: WG-MA/CON.
Supplying and erecting PVC trunking (PVC casing-n-capping) of size 40 mm with accessories on wall/ceiling as per specification No: WG-MA/CON.
Supplying & erecting mains with 2x1.5 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
Supplying & erecting mains with 1x1.5 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
Supplying & erecting mains with 2x2.5 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying & erecting mains with 2x4 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying & erecting mains with 4x6 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
Supplying & erecting mains with 1x6 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
Supplying & erecting mains with 4x10 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
Supplying & erecting mains with 1x2.5 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying & erecting mains with 2x1.5 sq.mm. F.R. copper wire, in 16 gauge 20 mm dia. Rigid Steel conduit with continuous GI earth wire of 2.5 sq.mm. as per specification No: WG-MA/MC.
Supplying & erecting mains with 2x2.5 sq.mm. F.R. copper wire, in 16gauge 20 mm dia. rigid steel conduit, with continuous GI earth wire of 2.5sq.mm. as per specification No: WG-MA/MC.
Supplying and erecting Ceiling rose / Batten holder / Slanting holder / hanging cord switch / hanging bell push / pendent holder bakelite base 6A. erected on filled polypropylene board or polished double wooden block/ PVC junction box.
Supplying and erecting ISI mark modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting ISI mark modular type switch 16A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting ISI mark modular type 32A, DP key tag switch with KEY TAG, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting ISI mark modular type 3 pin 6A multi sockets with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting ISI mark modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting ISI mark modular type T.V. socket single outlet, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting ISI mark modular type telephone socket two gang with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting ISI mark modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete. Note: Add Rs 57/- for additional two module box with double mounting plate if required.
Supplying and erecting PVC Surface modular switch box with double mounting plate for 1 module complete duly erected.
Supplying and erecting PVC Surface modular switch box with double mounting plate for 2 modules duly erected.
Supplying and erecting PVC Surface modular switch box with double mounting plate for 3 modules duly erected.
Supplying and erecting PVC Surface modular switch box with double mounting plate for 6 modules duly erected.
Supplying and erecting PVC Surface modular switch box with double mounting plate for 12 modules duly erected.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 1 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background..
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting 16 / 20 / 25 A starter (modular range) 2 module for AC unit on provided box complete & duly concealed with necessary material and connected.
Wiring for plug on board with Modular Switch socket, copper wiring and earthing as per specification No: WG-PW/SW
Wiring for plug on board with Switch socket concealed type, copper wiring and earthing and with modular accessories as per specification No: WG-PW/CW
Point wiring for light/fan/bell in 20 mm metal conduit with 1.5 sq.mm (2+1E) FR grade copper wire, flush type switch, earthing and required accessories as per specification No: WG-PW/SW
Point wiring for light/fan/bell concealed type in min 20 mm ISI marked HMS PVC conduit with 1.5 sq.mm. (2+1E) FR grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/CW
Point wiring for light/fan/bell hybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FR grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/HW
Point wiring in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FR grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW
CF Point wiring in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FR grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW
Staircase Point wiring in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FR grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW
Supplying & erecting telephone copper cable 5 pair with 0.5 mm dia. laid in provided PVC casing capping / conduit as per specification No. WG-TW
Supplying & installing UTP networking cat-6 cable suitable for LAN / WAN Computer net-working as per specification No. WG-COC/NC
Supplying and fixing tool-less Information Outlet (Ethernet) flush/surface type in provided modular box as per specification no. WG-NAS/IO
Supplying and erecting LED square / circular 16 to 20W down lighter having pressure die-cast aluminium housing, opal translucent cover, mounting arrangement with board for surface type or spring loaded mounting clips for flush type complete.
Supplying and erecting CRCA /die-cast aluminium powder coated housing LED panel light (slim edge-lit) square / round shape suitable for 19 to 24 W with provision for plane front frame with translucent cover fixed to the housing complete.
Supplying and erecting square / rectangular shaped CRCA /die-cast aluminium powder coated housing LED panel (slim edge-lit) light suitable for 25 to 32W with provision for plane front frame with translucent cover fixed to the housing complete.
Supplying and erecting square shaped CRCA /die-cast aluminium powder coated housing LED panel light (slim edge-lit) 600x600mm suitable for 36 W-40W with provision for plane front frame with translucent cover fixed to the housing complete.
Making suitable size recess in any type of false ceiling for erection of flush type down lighter and finishing the background to match the original surface upto 20W.
Making suitable size of recess in any type of false ceiling for erection of flush type LED panel light 600mm x 600mm and finishing the background to match the original ceiling surface.
Supplying & erecting LED 18W tube light fitting (4 feet) with polycarbonate housing, heat sink, integrated HF electronic driver complete.
Supplying and erecting LED Mirror Light with integrated driver including 7W to 9W lamp with polycarbonate housing and opal diffuser to be fixed above mirror or as required on clamps complete.
Supplying and erecting bulkhead fitting suitable for upto LED upto 12W fixed on wall. As per specification no. FG-IDF/BHF
Supplying & erecting suspension type decorative fitting with rise /fall arrangement, 1 light inside semi-circular metallic reflector with counterweight with guide pulley / spring buffer with work shop type copper flexible wire complete with necessary hook, if required.
Supplying and erecting ding dong / electronic musical type call bell with heavy duty coil suitable to operate on 230V A.C. supply erected on polished double wooden block/sunmica block of suitable size
Supplying and erecting luminous / modular type call bell indicator with plastic body, heavy duty coil and indicator lamp working on 230V A.C. supply with resetting arrangement complete erected on double wooden/ sunmica board
Supplying and erecting Electronic Type cordless call bell erected on T.W. board having portable bell push working on 9V D.C. battery and (effective range upto 45 meter) bell on 250 V A.C. supply.
Supplying and erecting LED Street light fitting suitable for above 40W to 48W lamp, including lamp, with PF > 0.95 class IP 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete per specification No . FG-ODF/FLS2.
Supplying and erecting Street light bracket for erection of side entry fitting on pole with 40 mm. dia. ‘B’ grade G.I. pipe of required length complete as per specification no. FG-BKT/SLB
Supplying & erecting 5W-7W, 230V integral type LED Lamp suitable for B-22/E-27 base.
Supplying and erecting fresh air cum exhaust fan of light duty250 V A.C. 50 cycles 225mm. 1400 RPM rust proof body & blades, wire mesh, duly erected in an approved manner.
Supplying and erecting five star rated energy saving Ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF
Supplying and erecting fan hook box of 10 mm M.S. round bar bounded to the R.C.C. bars upto 50 mm length each side and pierced through a 16 S.W.G. thick aluminium/M.S. Bowl 100 mm dia.or equivalent square size and having depth upto 75 mm complete erected with duly painted by one coat of red oxide paint and two coats of paint erected in position and without any leakage of slurry of cement concrete on either side of the box and positioned to the bottom level of the slab.
Supplying and erecting ‘B’ grade G.I. pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire.
Supplying, erecting & marking SPMCB 6A to 32A, C-series (for motor/power) in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking SPMCB 6A to 32A, B- series (for lighting) in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking TPMCB 40A to 63A in provided distribution board as per specification no. SW-SWR/MCB
Supplying & erecting triple pole and neutral distribution board (TPNDB) with door surface/ flush mounted SPMCB of 12 ways, on iron /GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB
Supplying & erecting triple pole and neutral distribution board (TPNDB) with door surface/ flush mounted suitable for 3 pole MCCB as incomer & outgoing SP MCB (12 poles) or TP MCB of 4 ways (12 poles) on iron/ GI frame. (vertical busbar type) as per specification no. SW-SWR/MCBDB1
Supplying & erecting triple pole and neutral distribution board (TPNDB) with door surface/ flush mounted suitable for 3 pole MCCB as incomer & outgoing SP MCB (24 poles) or TP MCB of 8 ways (24 poles) , on iron/ GI frame. (vertical busbar type) as per specification no. SW-SWR/MCBDB1
Providing & erecting 3 Pole MCCB upto 100A, 415V, with short circuit rating 25 kA (Ics=100% of Icu ),adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, in provided enclosure on iron /GI frame as per specification no. SW-SWR/MCCB
Providing & erecting 3 Pole MCCB of 200A,415V capacity with short circuit rating 25 kA (Ics=100% of Icu) adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, in provided enclosure on iron /GI frame as per specification no. SW-SWR/MCCB
Providing, erecting and commissioning 4 pole RCCB only of electromagnetic type with 30/100/300 mA sensitivity and having capacity of 40A complete as per specification no. SW-RCCB/RCCB
Providing & erecting floor / wall mounting, MCCB panel board with door suitable for four pole incoming 250A, 6 ways four pole outgoing upto 100 A MCCB's on iron frame, as per specification no SW-SWR/MCCBPB. (Excluding MCCB'S)
Providing & erecting incoming and outgoing cable alleys suitable for MCCB panel board with door of 250A incoming and 6 way outgoing or 400A incoming and 4 way outgoing made from CRCA sheet 1.6 mm thick duly powder coated and having vertical insulated partition for shielding between the shared face of cableway and DB complete.
Supplying and erecting air circuit breaker manually operated non-drawout type of 630A rated at 50º C without deration, 500V, 3 pole having short circuit rating 50 kA (Ics=Icu=Icw for 1s),with standard accessories and thermal magnetic release on provided iron frame as per specification no. SW-SWR/ACB
Supplying and erecting air circuit breaker manually operated non-drawout type of 1000A rated at 50º C without deration, 500V, 3 pole having short circuit rating 50 kA (Ics=Icu=Icw for 1s), with standard accessories and thermal magnetic release on provided iron frame as per specification no. SW-SWR/ACB
Supplying & erecting porcelain/epoxy bus bar support complete erected in provided MS box for 400A complete.
Supplying and erecting terminal spreaders for use on MCCB incoming and outgoing terminals for 3 pole upto 100A MCCB complete. (set of 6).
Supplying and erecting terminal spreaders for use on MCCB incoming and outgoing terminals for 3 pole upto 250A MCCB complete. (set of 6)
Supplying and erecting terminal spreaders for use on MCCB incoming and outgoing terminals for 3 pole 300A- 400A MCCB complete. (set of 6)
Supplying and erecting metal work in CRCA sheet with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete.(Note:-Above rates are inclusive of angle iron work.)
Supplying and erecting iron, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.
Supplying and erecting self-locking arrangement with keys in duplicate, made of brass duly erected, flush with surface of panel / cupboard.
Supplying and erecting bus bar chamber triple pole with neutral with four aluminium bars, 500V 800A complete as per specification no. CP-BB
Supplying and erecting LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates.
Supplying & erecting LED type indicating pilot lamp with LED colours red / yellow / green, 230 / 250V on provided box / panel with necessary material, wiring & connections etc.
Supplying & erecting LED type indicating pilot lamp with LED colour blue, 230 / 250 V on provided box / panel with necessary material, wiring & connections etc.
Supplying, erecting & terminating XLPE armoured cable 3½ core 25 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating XLPE armoured cable 3½ core 35 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating XLPE armoured cable 3½ core 50 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating XLPE armoured cable 3½ core 70 sq. mm. aluminium conductor with continuous 8.35 sq. mm. (10 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating XLPE armoured cable 3½ core 150 sq. mm. aluminium conductor with continuous 12.97 sq. mm. (8 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating XLPE armoured cable 3½core 240 sq. mm. aluminium conductor with continuous 12.97 sq. mm. (8 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating XLPE armoured cable 3½ core 300 sq. mm. aluminium conductor with continuous 12.97 sq. mm. (8 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating XLPE armoured cable 4 core 6 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating XLPE armoured cable 4 core 10 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating XPLE armoured cable 4 core 16 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying & laying (including excavation) 25 cm dia RCC Hume pipe of standard thickness at required depth up to 90 cms. below road / ground surface, for covering provided cable & necessary back filling with light ramming to make the road/ground surface as it was (Except bitumen carpet).
Providing & erecting Hot dipped galvanized perforated type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 150 mm width & 75 mm height complete with necessary coupler plates & hardware in approved manner.
Providing & erecting Hot dipped galvanized perforated type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 200 mm width & 75 mm height complete with necessary coupler plates & hardware in approved manner.
Providing & erecting Hot dipped galvanized perforated type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 300 mm width & 75 mm height complete with necessary coupler plates & hardware in approved manner.
Providing & erecting Hot dipped galvanized perforated type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 400 mm width & 75 mm height complete with necessary coupler plates & hardware in approved manner.
Providing & erecting Hot dipped galvanized cover suitable for perforated type cable tray manufactured from 18 swg (1.2 mm thick) GI sheet of 150 mm width & 20 mm height complete with necessary hardware in approved manner.
Providing & erecting Hot dipped galvanized cover suitable for perforated type cable tray manufactured from 18 swg (1.2 mm thick) GI sheet of 200 mm width & 20 mm height complete with necessary hardware in approved manner.
Providing & erecting Hot dipped galvanized cover suitable for perforated type cable tray manufactured from 18 swg (1.2 mm thick) GI sheet of 300 mm width & 20 mm height complete with necessary hardware in approved manner.
Providing & erecting Hot dipped galvanized cover suitable for perforated type cable tray manufactured from 18 swg (1.2 mm thick) GI sheet of 400 mm width & 20 mm height complete with necessary hardware in approved manner.
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP
Supplying and erecting copper strip of required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no. EA-EP.
Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint in an approved manner with joints required.
Supplying, installing, testing and commissioning FR, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU
Excavating hard murum / metal road by chiselling for preparing pit for poles stay or earth plates or for laying cables, pipes & clearing the site by removing debris & making the site as required complete.
Making burnt brick masonry with 1:6 ratio cement concrete duly plastered including watering, streaking joint on exposed faces, rocking at joint on exposed faces and watering complete.
Supplying and erecting RCC chamber cover with frame 60cmx 45cm medium duty 100kg with lifting arrangement including laying of angle iron frame of angle size as 50 x 50 x6 mm to be fixed / embedded on top of chamber complete.
Shubham EPC Private Limited
Bidder Name
Pawar Patkar Constructions Pvt.Ltd.
Shubham EPC Private Limited
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid