Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.5 LAccepted-AOC 13 218 MASJID EXTEN SADAR BAZAR | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹37.8 L+₹12.3 L (48.0%)Rejected-Finance | L2 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹47.0 L
EMD Value
₹93,900
Closing Date
26 Jan 2023, 6:00 pmClosed
GE South Delhi Cantt-10
GE South Delhi Cantt-10
REPAIR/REPLACEMENT TO PIPELINE AND PUMPS, MOTORS, DG SETS AND MISC WORKS AT KHANPUR, DUNDAHERA AND MANESAR ARMY CAMP UNDER AGE E/M OF GE (SOUTH) DELHI CANTT-10
2022_MES_572027_1
GE/DS-101/2022-23
Open Tender
Civil Works
Item Rate
270 days
GE South Delhi Cantt
Please refer Tender documents.
11 documents required · 11 mandatory
₹500
GE South Delhi Cantt
₹93,900
Yes
22 Feb 2023
29 Dec 2022
28 Jan 2023
29 Dec 2022
26 Jan 2023
12 Jan 2023
Amount
Supply, installation and comissioning of Altoch dosing system (Model ADS-1) decrin dosing pump consisting of 100 ltrs HDPE tank with level gauge along with agitator with shaft and blade in plastic mounted tank lid with have prothole for pouring of altoch for mounting decrin dosing pumo on the wall, and decrin dosing pump Model 96-NGQ 51 High pressure single head gear motor adjustable dosing pump with accessories and suitable electrical connection including taking out existing unserviceable Altoch dosing system of following specifications. Adjustable high pressure 0 to 100 PSO power 230 volt, 50 Hz, RPM-44, HP 1/30 fractional out put . 2 US GPD to 40 US GPD located at DW-6 Pump House complete all as specified and as directed.
Supply only chloroscope for water testing range of 0.1 ppm to 2.0 ppm (Make : Water Chem) complete all as specified and as directed.
Supply only ORTO-TOLUDINE regent solution in 500 ml bottle (Make : Glaxo/SDS/Water Chem/ACME Chemicals) complete all as specified and as directed
Supply only ALTOCH-GP high strength calcium based granular disinfectant for chlorination of water complete all as specified and as directed.
Supply only first Aid kit (PVC container) No-3 as per the specification including first aid medical treatment materials complete.
M&L cleaning of semi under ground sump of storage capacity of water 100000 gallons (01 No) at North Camp Khanpur capacity thoroughly by removing mud, dirt etc. from the sump by the following method complete all as specified and as directed:- (a) Cleaning inner surface of the tank by scraping with steel wire brushes and removing mud and sludge to be collected in the tank and removing the same to a distance not exceeding 50 meter or as directed by Engr-in-Charge. (b) Washing with clean water thoroughly complete tank internally and finally cleaning with bleaching powder. (c) writing date of cleaning on the sump with synthetic enamel paint (Height of each word not less then 100 mm)
M&L cleaning of semi under ground sump of storage capacity of water 25000 gallons (03 Nos) at South Camp Khanpur, Dundahera Mil Stn, Manesar Army Camp thoroughly by removing mud, dirt etc. from the sump by the following method complete all as specified and as directed:- (a) Cleaning inner surface of the tank by scraping with steel wire brushes and removing mud and sludge to be in the tank and removing the same to a distance not exceeding 50 meter or as directed by Engr-in-Charge. (b) Washing with clean water thoroughly complete tank internally and finally cleaning with bleaching powder. (c) writing date of cleaning on the sump with synthetic enamel paint (Height of each word not less then 100 mm)
M&L cleaning of overhead sump of storage capacity of water 25000 gallons (01 No) at Dundahera Mil Stn thoroughly by removing mud, dirt etc. from the sump by the following method complete all as specified and as directed:- (a) Cleaning inner surface of the tank by scraping with steel wire brushes and removing mud and sludge to be in the tank and removing the same to a distance not exceeding 50 meter or as directed by Engr-in-Charge. (b) Washing with clean water thoroughly complete tank internally and finally cleaning with bleaching powder. (c) writing date of cleaning on the sump with synthetic enamel paint (Height of each word not less then 100 mm)
Labour only for attending day to day external water supply compliants of all nature i.e. leakage in water supply pipe lines,fittings/Fixtures over flow of overhead tank, no water supply in two shifts from 0600 hrs to 1400 hrs (1st Shift) and 1400 hrs to 2200 hrs (2nd Shift) including noting the compliants from Khanpur North and South Army camp P/H, Dundahera Mil Station P/H & Manesar Army camp P/H in compliant register complete all as specified and as directed.(Any material required for attending complaints shall be measured & paid separately under respectvie item No.10.01 to 10.41)
Notes :- 1. The contractor shall make all arrangement for attending the different types of complaints at Khanpur, North & South Army Camp Pump House, Dundahera,Mil Station Pump House & Manesar Army Pump House on day to day basis. Any major item required to be replaced with new one, to make the system functional shall be measured and paid for separately as "M&L" under respective item of this schedule. Contractor has to provide adequate numbers of tradesmen with helper including all necessary T&P on all working days in two shift from 0600 Hrs to 1400 Hrs and 1400 Hrs to 2200 Hrs. Additional workers can be engaged if nature of work required to be completed within fix time frame as desired by the GE. Rate shall be quoted accordingly against these items, keeping in mind above said provisions. Any small fitting required to be replaced with new one, to make the system functional shall be measured and paid for seprately as 'Supply Only' under Srl item No. 10.01 to 10.41 of this schedule and the rate quoted by the tenderer are deemed to be included for fixing the same without any extra cost to the department. Old retrived item(s) as considered in 'Schedule of Credit' shall become property of the contractor
2. Proper records (date wise) of complaints received & rectified by the contractor and attendance register of trademen shall be maintained. 3. The contractor will ensure that the team of plumber and helper with necessary tools bag, shall always remain present at complaint cell to attend the complaints. 4. The complainted are to be attended immediately i.e. within 30 minutes. If the complaint not attended within 30 minutes necessary recovery (panelty) per complaint for not attending the complaint within stipulated time shall be made from the contractors claim as under :- (a) Not attending the complaint 30 minutes to 2 Hrs - Rs.50/complaint. (b) Not attending the complaint beyond 2 Hrs & upto 4 Hrs - Rs.100/complaint. (c) Not attending the complaint beyond 4 Hrs - Rs.200/complaint.
Supply only of following items/accessories in existing position complete all as specified and as directed of the following sizes:-
GI union 100 mm bore
GI union 75/80 mm bore
GI union 40/50 mm bore
GI union 20/25 mm bore
GI socket 100 mm bore
GI socket 75/80 mm bore
GI socket 40/50 mm bore
GI socket 20/25 mm bore
GI L bow 100 mm bore
GI L bow 75/80 mm bore
GI L bow 40/50 mm bore
GI L bow 20/25 mm bore
GI End plug 40/50 mm bore
GI End plug 20/25 mm bore
GI Tee 80/50 mm bore
GI Tee 50/40 mm bore
GI Tee 25/20 mm bore
GI Flange 80 mm dia
GI Flange 50 mm bore
Nipple 20 mm bore
Nipple 25 mm
Nipple 40 mm
Nipple 50 mm
GI Reducer medium grade 15 mm /20mm
GI Reducer medium grade 20 mm/25mm
GI Reducer medium grade 25 mm/40
GI Reducer medium grade 40 mm/50
GI Reducer medium grade 25 mm/15mm
GI Reducer medium grade 40mm/20mm
GI Reducer medium grade 40mm/25mm
GI Reducer medium grade 50mm/25mm
Gun metal gate valve 20 mm
Gun metal gate valve 25 mm
Gun metal gate valve 40 mm
Gun metal gate valve 50 mm
Float valve 20 mm bore
Float valve 25 mm bore
Lead pig Bar
Spurn Yarn
Nuts, Bolts and Washers 25 to 150 mm long of 6 to 20 mm dia
3mm thick rubber gasket
M&L for cutting of existing CI pipe in trenches of size 150/100 mm bore for new branch connections complete all as specified and as directed.
M&L cutting of existing GI pipe in trenches of size 80/50/40 mm dia for new branch connections complete and as directed.
Supply, lowering and fixing GI Column pipe heavy duty flanged & drilled ISI marked 80 mm dia, as per IS-1239, 3 Mtr long, GI flange 12mm thick, slots cutting in flanges for passing of submersible cable including all jointing material such as bolts, nuts, washers & packing sheet and connecting including taking down of existing GI column pipe compete all as specified and as directed.
Supply, lowering and fixing GI Column pipe heavy duty flanged & drilled ISI marked 50 mm dia, as per IS-1239, 3 Mtr long, GI flange 12mm thick, slots cutting in flanges for passing of submersible cable including all jointing material such as bolts, nuts, washers & packing sheet and connecting including taking down of existing GI column pipe compete all as specified and as directed.
S&F of GI water tubing, medium grade, galvanised (ISI marked as IS-1239), with all fittings including short lengths, fixed to walls, fixed in sewage well, U/G sump,borewells,concealed in wall and ceiling or laid in floor trench complete with all fittings (such as bends, elbows,flanges,Tee, short pieces,reducer,nipple, connectors, back nuts, diminishing pieces, caps and plugs, unions etc) including taking out of old unserviceable GI tubing complete, all as specified and as directed of the following sizes:-
100 mm bore
80mm bore
50mm bore
40mm bore
25mm bore
20mm bore
Supplying, laying, testing and commissioning of DI pipe of size 150 mm bore as per IS 8329,class K-7 with inside cement mortar lining with spigot and socket end laid in trenches including taking out of existing Unsv pipe complete all as specified and as directed. Note : Earth work shall be measured and paid separately
S&F in repairs of old unserviceable overload relay MN 4.5-7.5/ MN 6-10 /MN 9-15 Amps and connected internal wiring complete all as specified and as directed . Note:- The rate is inclusive of connection out the starter before replacement of overload relay and make the connection after replacement of overload realy.
S&F in repairs of old unserviceable overload relay MN 20-33 Amps and connected internal wiring complete all as specified and as directed. Note:- The rate is inclusive of connection out the starter before replacement of relay and make the connection after replacement of realy.
S&F in repairs of old unserviceable contactor MNX 18 Amps and connected internal wiring complete all as specified and as directed. Note:- The rate is inclusive of connection out the starter before replacement of contactor and make the connection after replacement of contactor.
S&F in repairs of old unserviceable contactor MNX 25 Amps and connected internal wiring complete all as specified and as directed. Note:- The rate is inclusive of connection out the starter before replacement of contactor and make the connection after replacement of contactor.
S&F in repairs of old unserviceable contactor MNX 32 Amps and connected internal wiring complete all as specified and as directed. Note:- The rate is inclusive of connection out the starter before replacement of contactor and make the connection after replacement of contactor.
S&F in repairs of old unserviceable contactor MNX 40 Amps and connected internal wiring complete all as specified and as directed Note:- The rate is inclusive of connection out the starter before replacement of contactor and make the connection after replacement of contactor.
S&F in repairs of old unserviceable single phase preventor and connected internal wiring suitable for 10 HP motor starter complete all as specified and as directed. Note:- The rate is inclusive of connection out the starter before replacement of single phase preventorr and make the connection after replacement of single phase preventor.
S&F in repairs of old unserviceable single phase preventor and connected internal wiring suitable for 15 HP motor starter complete all as specified and as directed. Note:- The rate is inclusive of connection out the starter before replacement of single phase preventorr and make the connection after replacement of single phase preventor.
S&F in repairs of old unserviceable phase sequence corrector relay 440V , 50 HZ Supply suitable for 15 HP motor starter and connected internal wiring complete all as specified and as directed. Note:- The rate is inclusive of connection out the starter before replacement of phase sequencer and make the connection after replacement of phase sequencer.
S&F in repairs of old unserviceable phase sequence corrector relay 440 Volts, 50 HZ suitable for 10 HP motor starter and connected internal wiring complete all as specified and as directed. Note:- The rate is inclusive of connection out the starter before replacement of phase sequencer and make the connection after replacement of phase sequencer.
S&F in replacement of old unserviceable phase sequence corrector relay 440 Volts, 50HZ suitable for 7.5 HP motor starter and connected internal wiring complete all as specified and as directed. Note:- The rate is inclusive of connection out the starter before replacement of phase sequencer and make the connection after replacement of phase sequencer.
S&F in repairs of old unserviceabel digital voltmeter of range 0-500 volts and connected internal wiring suitable for submersible/booster/sewage motor starter complete all as specified and as directed.
S&F in repairs of old unserviceabel digital Ammeter of range 0-100 Amps and connected internal wiring suitable for submersible/booster/sewage motor starter complete all as specified and as directed.
S&F in repairs of old unserviceable indication lamp in R, Y, B colour and connected internal wiringin for motor starter complete all as specified and as directed.
S&F in repairs of old unserviceable Rotary switch and connected internal wiring for motor starter complete all as specified and as directed.
S&F in repairs of old unserviceable push button and connected internal wiring for motor starter complete all as specified and as directed.
M&L for spray painting (including bringing compressor of suitable size at site) old painted steel or iron surface of (12.5 to 30 KVA) DG set complete with engine, alternator, radiator, exhaust hood and other satandard fittings & attachments (excluding diesel tank) as per existing colour scheme and pattern with atleast one coats of synthetic enameled paint after duly preparing the surface by cleaning with scrapers and emrey paper to the entire satisfaction complete all as specified and as directed.
M&L for spray painting (including bringing compressor of suitable size at site) old painted steel or iron surface of centrifugal pumping set 5 to 30 HP complete with motor, pump, base frame and other satandard fittings & attachments as per existing colour scheme and pattern with atleast one coats of synthetic enameled paint after duly preparing the surface by cleaning with scrapers and emrey paper to the entire satisfaction and complete all as specified and as directed.
Supply, installation, testing & commissioning in repairs of digital water level monitoring system at UG sump with innovative piezo-resistive linear sensor non ambigous display 3 ½ digit (1999 counts maximum) unit options: any two of Cm, Ltr/Kltr, % (percent), resolution: 0.1 for % and 1 Cm upto 20 Mtrs deep tank DATUM: level adjustable power: 10-14 VDC (5 watts) temperature: 0-550 celsius Relay: NO-230 VAC, 6 Ampere sensor on tripod stand no electrical contact with water no-long-term effect of salinity on sensor complete all as specified and as directed with followings:- (a) Wall hanging bracket IPX2 enclosure 420mmx210mmx240mm. (b) SMPS power adaptor (5 watts). ( c) 12V/220 volts input hooter facility. (d) Audible alarm facility. Make : IPC (IPCDLLMS) / Kratos (KELMS100).
M&L for development of tube well for improvement of water yield by 630 CFM compressor including taking out existing submersible pump set complete with pipe and cable and lowering the same after water yield improvement including necessary T&P and minor spare parts complete all as specified and as directed.
M&L for Lifting of submersible pumping set of any capacity from deep bore well with chain and pulley arrangement including lowering down the submersible pump set after repair complete all as specified and as directed.
M&L for complete overhauling/opening for repair/replacement of defective parts of submersible/sewage pump of 5-7.5 HP and fixing of following new spares of pumps which shall be measured and paid seperately under respectiveitems of capacity 5HP to 7.5 HP, 3 phase motor driven (excluding motor) cast iron/cast steel body complete and connecting with motor portion complete all as specified and as directed of the following sizes:-
CI Stage bowl.
GM neck ring.
Remetling of GM impeller turning.
GM DOL bush.
SS stud with nut.
Water seal
Revolving disc
EPV Impeller.
Impeller key.
Repairing of stamping of stator.
CI DOL piece.
SS coupling with key.
CI Suction piece.
GM sand guard.
All as per Srl item No.40 above here-in-before 10-12.5 HP capacity complete all as specified and as directed are the following sizes:-
CI Stage bowl.
GM neck ring.
Remetling of GM impeller turning.
GM DOL bush.
SS stud with nut.
EPV Impeller.
Impeller key.
Repairing of stamping of stator.
CI DOL piece.
SS coupling with key.
CI Suction piece.
GM sand guard.
Labour only for Opening the submersible pump set / sewage pump/Booster/centrifugal/monoblock set of capacity 5 HP to 25 HP including taking down/out the burnt winding wire cleaning the slots, rewinding the motor with super enamelled copper winding wire of existing gauge, weight etc, repairing the same by replacing the unserviceable parts including machine/ lathe work and re-assembling the pump set in original position with required insulating material to make it fully functional complete all as specified and as directed. Notes:- 1. The copper required for rewinding and other fittings shall be measured and paid separately under relevant item as S&F under Srl item No. 43 & 44.01 to 44.12 & 52.01 to 54 here-in-after. 2. The rate quoted by the tenderer are deemed to be included for transporting the pump from site to repair shop and back after repair. 3. The Contractor shall have to make the alternative arrangment of repairable pump for smooth supply of water and the rate quoted by him are deemed to be included for the same. 4. The repairs work shall be carried out at authorised dealer of Pump motor and necesasry proof of repair (invoice) shall be submitted by the contractor.
Supplying and assembling super enamelled copper winding wire of appropriat gauge and weight suitable up to 25HP pumping sets complete all as specified and as directed.
S&F in replacement of following spares of monoblock/ centrifugal/ booster pumpset of capacity 5HP to 12.5HP complete all as specified and as directed.
GM bearing bush.
SS Rotor sleeve.
Cable seal.
Thrust bearing.
Thrust Plate
Sealing Ring.
Motor seal 10 mm
Motor seal 25 mm
O ring
CI Lower housing.
CI upper housing.
Remetling of rotar & turning.
S&F in repairs submersible cable flat 6 Sqmm 3 core for bore well of any depth with fitting and connections complete all as specified and as directed.
M&L for Lifting of motor/ pumping set from the existing sewage well of any depth with chain and pulley arrangement and lowering down the motor/pumping set after repairing complete all as specified and as directed.
M&L for disposal of waste water up to 12 feet depth of Sewage well and 08 Feet depth of Man Hole by using Portable sewage pumping set of capacity 12 HP and filling of waste water in a covered trolley and disposed off outside MD land all as specified and as directed. Note : The measurment shall be arrived by computing the volume. Thevolume of sewagewell/manhole upto top level of waste water
M&L for removal of Sludge/Mud/Muck/Waste material/Silt upto a depth of 26 feet, Desilting/Dechocking with high pressure super socker machine and cleaning of surface of sump of sewage well using wire brushes and other scrapping tools to remove dirt and scales to make it free from all deposits and disposed of the same to outside MD land all as specified and as directed. Note :- 1. The Engr-in-Charge/JEs cncern shall keep the record of running of super sucker machine with date and time Machine number & necessary gate pass of 'IN' and 'OUT' of respective machine. These documents shall be signed by both the party i.e. contractor and Engr-in-Charge.
M&L for preparation of monoblock pump of capacity up to 15HP at site and applying two coats of synthetic enamel paint over and including one coat of red oxide primer complete all as specified and as directed.
Blank
Blank
S&F in repairs of following spares of monoblock/centrifugal/booster pumpset of capacity 15HP to 25HP complete all as specified and as directed.
Bush complete all as specified and as directed.
Bearing
Brass Impeller
Glands packing complete all as specified and as directed.
Alignment of motor shaft including Lathe work complete all as specified and as directed.
Blank
Servicing of DG set upto 30 KVA of any make at Khanpur Army camp,Dundahera Mil station,Manesar Army camp by taking out U/S spares, Cleaning by brushing to remove dust including cleaning of filter,Checking of all nuts, bolts tightening whereever necessary, check up engine oil level, coolant level and Labour for top up if necessary, adjustment belt tension,Tuning of engine, adjustment of speed, alternator voltage, frequency etc greasing oiling and checking For smooth functioning of DG Set complete all as specified and as directed. Note- 1. Any spares,Engine oil,coolant,unserviceable spares required to be replaced shall be measured paid for separately under respective items. 2. Minor spares like nuts,bolts etc cost up to Rs 200 shall be included in the rate quoted above
M&L for "B" Check DG set upto 30 KVA of any make at Khanpur Army camp,Dundahera Mil station,Manesar Army camp by taking out U/S spares, Cleaning by brushing to remove dust including labour for Changing engine oil, coolant etc to max level, adjustment belt tension,Tuning of engine, adjustment of speed, alternator voltage, frequency etc greasing oiling and checking For smooth functioning of DG Set complete all as specified and as directed. ( Note :- Any spares,Engine oil,coolant,unserviceable spares required to be replaced shall be measured and paid separately under respective items as "M&L" or "S&F".
S&F in repairs of oil filter set for 20 to 35 KVA DG set complete all as specified and as directed.
S&F in repairs starter key switch for 20 to 35 KVA DG set complete all as specified and as directed.
S&F in repairs of Battery Terminal made of brass nut & bolt complete all as specified and as directed.
M&L for repair and calibration to fuel injection pump & nozzle for 20 to 35 KVA DG set complete all as specified and as directed.
S&F of fuel filter set for 20 to 35 KVA complete all as specified and as directed.
S&F of pipe (Fuel line) set for 20 to 35 KVA complete all as specified and as directed.
S&F of radiator hose pipe set for 20 to 35 KVA complete all as specified and as directed.
M&L engine oil as per manufacturers suggested grade complete all as specified and as directed.
M&L for Topping up of coolant complete all as specified and as directed.
S&F in repairs of temperature gauge for DG Set make: (As per sample) all as specified and as directed.
S&F in repairs Off load Changeover Switch - AC 23 (side handle) in sheet enclosure, 415 Vac, 50 Hz. 4 pole 100 Amp/415 volts on load side handle operated type inclduing taking down old change over complete all as specified and as directed. Cat Part No IHBFFE0100 of Havells or equipvalent Make: HPL/L&T/Standard.
Supply, fixing, jointing & testing CI sluice valve of size 150mm, ISImarked, flanged ends drilled pressure rating PN-1.0, PD short body, confirming to IS 14846-2000 having stainless spindle with cast iron operation wheel at top including taking out unsv sluice valve complete all as specified & directed. Note:Flanged joints complete with jointing material shall be deemed to be included in the unit rate of this item
All as per Srl item No. 61 above but, 100 mm size.
All as per Srl item No. 61 above but, 80 mm size.
S&F in repairs of CI flanged Foot Valve confirming to IS 4038 complete of size 80mm (3") dia in replacement of old u/s foot valve complete all as specified and as directed.
S&F in repairs non return valve flanged end complete of size 150mm dia (6") dia including all fixing materials like rubber gasket, nuts, bolts, washer etc all as specified and as directed. Make:-Leader/Jindal/Kartar.
S&F in repairs non return valve flanged end complete of size 100mm dia (4") dia including all fixing materials like rubber gasket, nuts, bolts, washer etc all as specified and as directed . Make:-Leader/Jindal/Kartar.
S&F in repairs non return valve flanged end complete of size 80mm dia (3") dia including all fixing materials like rubber gasket, nuts, bolts, washer etc all as specified and as directed Make:-Leader/Jindal/Kartar.
S&F in repairs cast iron butterfly valve for 80 mm bore pipe, with iron handel/lever complete all as specified and as directed. Make Leader/Jindal/Sant
S&F in repairs of battery 180 Ah,12 Volts maintencance free including battery termail alongwith connectiing wire of suitable gauge upto 2 mtr length min as required on site all as specified and as directed Make:- Exide/Amaron/ Luminious.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for laying of cables or other items and getting out soil in soft/loose soil complete all as specifed and as directed.
Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm complete all as specified and as directed.
Removing excavated material not exceeding 50 mtr and depositing where directed in a level not exceeding 1.5 mtr above the starting point of any type of soil complete all as specified and as directed.
Boring holes under road pavement by bocky manually in any type of soil upto 200 mm bore complete all as specified and as directed.
M&L for construction of valve pit of size 100 cm x 100 cm x 110 cm (internal dimensiions), stone/ brick construction, including all necessary excavation and earth work in any type of soil, returning, filling in disposal of surplus soil to distance not exceeding 50 m and depositing where directed, PCC in foundation of the mix (1:2:4) type D-2, brick masonary in cement mortor (1:4) rendering 12 mm duck in cement mortar (1:4) internally, finished even and smooth and pointing flush externally as the work proceeds in the same mortor. Mild steel angle iron 40 x 40 x 6mm frame MS sheet cover 3.15 mm thick with handle and locking arrangement, painting all the exposed MS work with two coats of synthetic enamel paint of the that as approved by the GE over a cost of red oxide primer and painting all the MS embedded in PCC with two coats of black bitumenous paint and complete all as specified and as directed.
Testing of drinking water being collected from local source(bore well/Shallow wells/under ground sumps) in the area under AGE E/M South and submission of detailed test report to the office to complete all as specified and as directed as detailed below :-
(a) Colleciton of water from different sources of water ie sump, bore wells & shallow wells in sterilized bottle.
(b) Carrying out minimum essential testing of water as per IS 10500-1991 mandatory for chemical colour, odour taste, surbidity, PH value TDS total hardness, iron chloride, fluride and residual free chlorine and Bacteriological total E collie form organisms per 100 ml (MPN) and E Collie in 100 ml) and submitting to this office with specific recommendaiton regarding suitability of water for drinking purpose.
Note for Srl item No.75 :- Rate quoted shall ldeemed to be included for :
(i) Cost of sterilized bottle as required
(ii) To and fro transportaiton charges for collection of samples from sources (sump/bore well/shallow wells)
(iii) The contractor shall produce water test certificate while claming the RAR.
Comprehensive, preventive and periodical maintenance of RO Plant (01 Nos) of capacity 1000 LPH Make: AQUAFRESH installed at Dundahera Mil station in reliable, safe and efficient manner by regular examining, lubricating and adjusting the mechanical and electrical driving equipment including repacement of defective / spares parts as "Supply only" and testing on completion to the entire satisfaction of Engr-in-charge complete all as specified and as directed. Note: (i) Spare parts will be measured & paid separately. (ii) All the complaints will be rectified within 24 hrs from the time of receipt of complaint. If contractor fails to rectify the complaint within 24 hrs from the time of receipt of complaint, the compensation / penalty of Rs 500.00 per complaint per day shall be recovered from the contractor's dues.
Removing the existing media and supply and filling of dual media of same size as removed for DMF of RO plant at Dundahera Army camp without damaging the plant, pipelines and other accessories and leading the removed media upto 2km complete all as specified and as directed.
Removing the existing media and supply and filling of carbon media for activated carbon filter of RO plant at Dundahera Army camp without damaging the plant, pipelines and other accessories and leading the removed media upto 2km complete all as specified and as directed.
Supply only in repair of micron filter (1000 LPH/20 inch) to remove particle up to 20 micron and reduce silt density index further to acceptable levels complete all as specified and as directed.
supply only in repair of reverse osmosis membrane system (brackish water) to remove major part of TDS (85 - 95%) with sundry fitting, arrangement & skid to meet adequate permate of minimum 50% recovery complete all as specified and as directed.
Note:- The contract sum shall be after deducting the amount of Credit shown in Credit Schedule of this Tender.
Surjit and Sons
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .