Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.3 LAccepted-Finance | ₹7.3 L | L1 | Accepted-Finance L1 |
| 2 | L2₹7.4 L+₹15,030.49 (2.07%)Accepted-Finance | ₹7.4 L+₹15,030.49 (2.07%) | L2 | Accepted-Finance L2 |
| 3 | Rejected-Technical | - | - | Rejected-Technical Technically disqualified |
| Sl No | Description | Qty | Unit | M/S Power source L3 | Shree Shantadurga Power Solutions L2 | RAY VISION CONSTRUCTION LLP L1 |
|---|---|---|---|---|---|---|
| 1.00Supplying of 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 | ||||||
| 1.10 | 3.5C x 95 sq.mm Aluminium Conductor | 500 | Mtr | 1,050 ₹5,25,000 | 824.68 ₹4,12,340 | 800 ₹4,00,000 Lowest |
| 2.00 | Supply and laying of Service cable-4 sq.mm with terminations | 200 | Mtr | 110 ₹22,000 | 50 ₹10,000 Lowest | 150 ₹30,000 |
| 3.00Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. | ||||||
| 3.10 | Above 35 sq. mm and upto 95 sq. mm | 460 | Mtr | 85 ₹39,100 Lowest | 153.4 ₹70,564 | 100 ₹46,000 |
| 4.00Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. | ||||||
| 4.10 | Above 35 sq. mm and upto 95 sq. mm | 40 | Mtr | 180 ₹7,200 | 383.5 ₹15,340 | 100 ₹4,000 Lowest |
| 5.00Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). | ||||||
| 5.10 | 4 way (4 + 12), Double door | 1 | Each | 4,800 ₹4,800 Lowest | 5,094.41 ₹5,094.41 | 15,000 ₹15,000 |
| 6.00Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in metal enclosure including drilling holes in,making connections, Ics=100% Icu and Operational Voltage 690V etc. as required. | ||||||
Tender Value
₹7.7 L
EMD Value
₹15,318
Closing Date
22 Jan 2026, 11:00 amClosed
Executive Engineer (Electrical)
IWD Office IIT Goa
Making temporary lighting arrangement for erstwhile IHMCT campus
2026_ITG_893873_1
IITGOA/IWD/2025/26 dtd 14.01.2026
Open Tender
Electrical Works
Works
90 days
IIT Goa
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹15,318
2 Feb 2026
14 Jan 2026
23 Jan 2026
14 Jan 2026
22 Jan 2026
14 Jan 2026
14 Jan 2026 - 22 Jan 2026
Supplying of 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975
3.5C x 95 sq.mm Aluminium Conductor
Supply and laying of Service cable-4 sq.mm with terminations
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
Above 35 sq. mm and upto 95 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.
Above 35 sq. mm and upto 95 sq. mm
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).
4 way (4 + 12), Double door
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in metal enclosure including drilling holes in,making connections, Ics=100% Icu and Operational Voltage 690V etc. as required.
100 A,30KA,FPMCCB
Supplying and fixing following 4pole MCB of rated ampere in existing Distribution board including terminations and complete
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
SP MCB
DP MCB
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required
3½ X 95 sq. mm (45mm)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
6 Module (200mmX75mm)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 A switch
15/16 A switch
3 pin 5/6 A socket outlet
6 pin 15/16 A socket outlet
LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥105 <120 lm/Watt). Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as perIEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K /4000°K / 5700°K /6500°K (As per ANSI Bin) ,SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-inCharge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C)
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. i) Hard Rock (blasting prohibited)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : i) 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
Providing and supplying bamboo of minimum dia 25mm and minimum height 6 metres for laying of overhead electricity cable
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.58 MB
BOQ_939546.xls
BOQ • 0.34 MB
NIQIHM26.pdf
Tender Documents • 0.56 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .