Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹92.8 LAccepted-AOC TP 117 2ND FLOOR MAURYA ENCLAVE PITAMPURA DELHI 110034 | DELHI | DELHI | DELHI | 110034 | L1 | Accepted-AOC Being lowest and reasonable tender | |
| 2 | L2₹95.6 L+₹1.2 L (1.22%)Rejected-Finance | L2 | Rejected-Finance Being second lowest tender |
Tender Value
₹1.5 Cr
EMD Value
₹2.2 L
Closing Date
12 Sept 2024, 6:00 pmClosed
CWE AF PALAM
HQ CWE(AF) PALAM, DELHI CANTT-10
SPECIAL REPAIR TO CERTAIN OFFICES OF CHOC COMPLEX AT SUBROTO PARK UNDER GE(AF) SUBROTO PARK,DELHI CANTT-10
2024_MES_664029_1
CWE/PM/SP-10/2024-25
Open Tender
Miscellaneous Works
Item Rate
330 days
GE AF SUBROTO PARK
As per tender documents
10 documents required · 10 mandatory
₹1,000
GE AF SUBROTO PARK
₹2.2 L
25 Sept 2024
4 Jul 2024
19 Sept 2024
4 Jul 2024
12 Sept 2024
27 Jul 2024
Amount
BUILDING WORK :- Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) ,removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engr-in-Charge.
S&F coloured vitrified tiles 9 to 10 mm thick 600 mm x 600 mm joint free tiles, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed by Engr-in-Charge.
All as per ser. item No 2 above but as in vertical surfaces such as dado/skirting over and including 10 mm thick rendering in cement mortar 1:4 complete all as specified and directed by Engr-in-Charge.
M&L for Non skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tiles exc 0.11 sqm but n. exc 0.18 sqm, in floors, joint free tiles, set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15 mm thick screed bed or bedding layer in cement mortar 1:6 complete all as specified and directed by Engr-in-Charge.
M&L for Glazed printed/ coloured ceramic tiles in vertical surface 300x 600x 7 mm / 450X 300X 7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick rendering in cement mortar 1:4 complete all as specified and directed by Engr-in-Charge.
M&L for chequered cement concrete 20X20 cm/ 30X30 cm tiles of 25 mm thickness laid jointed and pointed in cement mortar with grey pigment cement and pigments , laid over and and including screed bed , 15 mm thick in cement mortar 1:6 complete all as specified and directed by Engr-in-Charge.
M&L 25 mm thick, plain cement concrete 1:2:4 type B0 using 12.50 mm graded stone aggregate as in sub base finished even and fair complete all as specified and directed.
M&L glazed ceramic tiles in vertical surface 350X250X7mm/450X350X7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10 mm thick rendering in cement mortar 1:4 complete all as specified and directed by Engr-in-Charge.
Taking up or down steel tubing and connections including all fittings for 15 mm bore GI tubing complete all as specified and directed by Engr-in-Charge.
Taking up or down steel tubing and connections including all fittings for 20 mm bore GI tubing complete all as specified and directed by Engr-in-Charge.
S&F GI tubing ,medium grade, galvanised with all fittings fixed complete to walls and ceilings or laid in floors for 15mm bore pipe concealed / open complete all as specified and directed by Engr-in-Charge.
S&F GI tubing ,medium grade, galvanised with all fittings fixed complete to walls and ceilings or laid in floors for 20mm bore pipe concealed / open complete all as specified and directed by Engr-in-Charge.
S&F in repair vitreous china wash down water closet tank (pedestal pattern one piece) white, size 65.5 X 38.5 X 76.5 cm with integral flushing system including making good complete all as specified and directed by Engineer-in-Charge. (Make:Hindware CAT No 92562S-22 or equivalent in Cera/Jaquar/Johnson).
S&F in repair vitreous china wash basin white oval type size as directed by EIC white in colour, fitted in counter platform of granite stone (Granite stone shall be measured separately) including waste coupling for WHB with long screwed and shanks and fly nuts, flanged end bedded in red lead and other end fixed, PVC waste pipe, 32mm dia ,medium grade, pipe with fittings fixed in wall connected to floor trap for drain out, complete all as specified and directed. (Make:Hindware/Parryware/Cera of Ist quality).
Supply and Fixing in repair factory made PVC kitchen/cupboard frame of the size 75mmX40mm with a wall thickness of 4 mm made out of extruded 4 mm thick prelam PVC sheet of density 600 kg/Cum manufactured by an ISO 9000 certified company, reinforced with 15 mm X 15 mm MS square tube of 19 gauge thickness throughout the frame and mitre cuts at two corner and jointed with 2 Nos of 150 mm long bracket of 10 mm X 10 mm MS square tube. the door frame shall be fixed to the wall using 65/100 long MS screw a minimum of 4 Nos of screw to be provided for each vertical member and minimum of two Nos of Screw to be provided for horizontal member etc all as per direction of Engr- in-charge.
S&F in repair factory made PVC 18mm thick pre laminated both sides Celuka ply for cabinet sides, shelves, partitions, top and bottom, sides including backing of cabinet fixed with each other with steel screws and solvent cement adhesive including 1mm thick PVC lipping all-round the cabinet and shelves or as per manufacturing specifications complete all as specified and directed by Engr-in-Charge.
S&F aluminium handles of 125 mm size for cabinets shutters complete all as specified and directed by Engr-in-Charge.
S&F stainless steel grade 304 for telescopic channel of size 18 inch suitable for cabinets complete all as specified and directed by Engr-in-Charge.
S&F stainless steel grade 304 for Self closing hinges suitable for cabinets complete all as specified and directed by Engr-in-Charge.
M&L for factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 65x100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners will not be paid separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
M&L for factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm thick comprising of virgin polymer of K value 58-60(Suspension Grade), 2, 4, or 6 raised panel design calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and nontoxic additives (maximum toxicity index of 12 for 100gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge),minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge.
S&F butt hinges heavy weight 100 mm long mild steel fixed with steel screw complete all as specified and directed by Engr-in-Charge.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) not exc 1.5 Sqm each, including removing, making good after fixing of new chowkhat to match existing finish complete all as specified and directed by Engr-In-Charge.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) exc 1.5 Sqm but n exc 4 Sqm each,including removing complete and making good after fixing of new chowkhat to match existing finish complete all as specified and directed by Engr-In-Charge.
Providing & fixing in repairs false ceiling with Semi perforated 12mm thick acoustical false ceiling, (fire retardant and sound absorbent) micro regular edged at all heights with GRG (Glass Fibre reinforced Gypsum) false ceiling tiles of size 595x595 mm of approved texture, design and pattern having moisture content less than 2%, humidity resistance of 99% NRC 0.85 (with 50 mm thick glass wool) as per IS 8225:1987, Non-combustible as per BS 475 (Part 4) -1970 and light code description unit rate No 429 Sub Head : 26.0 NEW TECHNOLOGIES AND MATERIAL reflectance of 85% minimum to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanised iron section of 0.33 mm thick (galvanised @ 120 grams per sqm including both sides) comprising of maint -T runners of size 15x32mm of length 300mm, cross -T of size 15x32 of length 600mm to form grid module of size 600x600mm , suspended from ceiling using galvanised mild steel items (galvanising @80 grams per sqmm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm length and L-Shape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x24x0.40mm of length 3000mm to be fixed on perimeter wall /partition with the help of plastic rawl plugs at 450mm centre to canter and 40mm long dry wall screws. The work shall be carried out as per specification, drawing and as per direction of the Engr-in charge. (Make : Diamond & Equivalent).
Providing and fixing in repairs in position wall panelling at all heights (fire retardant and sound absorbent) with GRG ( Glass Fibre Reinforced Gypsum) panels/tiles of 10 mm thick fully perforated suitable for acoustic purpose of size 595 x 595 mm of approved texture, design and pattern having moisture content less than 2%, humidity resistance of 99%, NRC 0.85 as per IS 8225:1987, Non combustible as per BS 476 (Part 4)-1970 and light Reflectance of 75% to 85% (Minimum), comprising of a frame made from especially fabricated galvanised mild steel sheet 0.50 mm thick pressed section (galvanising @ 120 grams per square metre including both sides) i.e vertical studs of size 48 x 34 x 36 mm are placed at 600 mm centre to centre in a floor and ceiling channel section of nickel coated size 50 x 32 mm fixed to the floor and ceiling at 600 centres using 12 mm dia, 50 mm long wedge type expanded zinc alloy dash fasteners with 10 mm bolt. The same channel is then to be fixed in horizontal direction at 600 centre to centre so as to form a grid of 600 x 600 mm. Glass wool of 50 mm thickness is then to be inserted in the slots and finally GRG ( Glass Reinforced Gypsum) non combustible panels/tiles are to be screw fixed with self tapping pan head nickle coated mild steel screws of size 13 x 3.2 mm on this grid leaving an even groove of 1 mm between the panels. The joint between the panels are to be duly jointed and finished using recommended jointing compound and fibre joint tape roll 50 mm wide ( 90 meter) roll and two coats of primer suitable for panelling as per manufacturer's specifications as per directions of Engineer-in-charge all complete. (Make : Diamond & Equivalent).
Taking down cement or cement lime plaster of any description on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed by the Engineer-in-Charge
M&L for rendering 15mm thick on internal surfaces of brick work/stone work or concrete surfaces in cement mortar 1:6 finished without using extra cement complete all as specified and directed by the Engineer-in-Charge
M&L for rendering 10mm thick on soffits/ceiling surfaces of brick work/stone work or concrete surfaces in cement mortar 1:3 finished even and smooth without using extra cement complete all as specified and directed by the Engineer-in-Charge
M&L for rendering 15mm thick on external surfaces of brick work/stone work or concrete surfaces in cement mortar 1:4 finished even and fair complete all as specified and directed by the Engineer-in-Charge
M&L applying three coats of white wash on ceiling, soffit of chajjas facia etc. newly plastered surfaces including preparation complete all as specified and as directed by the Engineer-in-Charge.
M&L for distempering with Ist class acrylic distemper (ready mixed) having VOC content less than 50 gm/litre, of approved manufacturer, of required shade and colour complete as per manufacturer's specification,Two or more coats on new work including preparation of new plastered surfaces complete all as specified and as directed by the Engineer-in-Charge
M&L for applying two or more coats of 100% premium acrylic exterior emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489-2014, Alkali and fungal resistance, dirt resistance exterior paint of required shade with silicon additives @ 1.43 litre/10sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over new plastered surfaces of wall/soffits of chajjas etc. including preparation complete all as specified and as directed by the Engineer-in-Charge
M&L for distempering with 1st class acrylic distemper (ready mixed) having VOC content less than 50 gm/litre, of approved manufacturer, of required shade and colour complete as per manufacturer's specification, Two or more coats on old work including complete removal of existing finishes with and including a coat of primer complete all as specified and as directed by the Engineer-in-Charge
M&L for finishing wall with Acrylic smooth exterior paint of required shade: old surfaces ( two or more coats applied @ 1.67 Ltr/10 Sqm over and including priming coat of exterior primer applied @ 2.20 Kg/10 Sqm) including complete removal of existing treatment from walls and preparation of surfaces complete all as specified and as directed by the Engineer-in-Charge
M&L applying wall care putty average thickness 3mm on wall surfaces old/new to bring the surfaces even and smooth complete all as specified and as directed by the Engineer-in-Charge
M&L for any coloured granite (of any size) 18-20 mm thick table rubbed and polished as in cooking platform, slab as in wash basin counters and in similar situations, machine cut laid over and including 15 mm thick screed bed in CM 1:4, laid and jointed with grey cement slurry and including pointing in white cement (1:2) using marble dust with admixture of pigment to match with granite shade including cutting and polishing complete all as specified and as directed by the Engineer-in-Charge
All as per item No 37 above but as in vertical surfaces such as dado/skirting laid over and including rendering 10 mm thick in CM 1:4 jointed with grey cement slurry and including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade including cutting and polishing and dismantling old stone slab complete all as specified and as directed by the Engineer-in-Charge
S&F in repair PVC (SWR) floor trap 75 mm dia out let, plain with cockroach proof stainless steel grating including jointing with solvent cement complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair PVC (SWR) pipes of 75 mm bore, single socketed in any length with rubber ring joints laid in trenches, floors or fixed in walls complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair PVC (SWR) pipes of 110 mm bore, single socketed in any length with rubber ring joints laid in trenches, floors or fixed in walls complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair PVC (SWR) bends, tees, elbows, branch piece single or (Y) equal or unequal with or without inspection chamber of 75 mm bore complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair PVC (SWR) bends, tees, elbows, branch piece single or (Y) equal or unequal with or without inspection chamber of 110 mm bore complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair as brass chromium plated shower rose of 125mm size complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair kitchen sink with drainage board made of stainless steel 1.00mm thick with plugs, washers & wastes including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mmx460mm bowl size 410mmx330mmx160mm. ISI marked complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair plate rack as in repair of size 1000 X 750 X 250 mm stainless steel made out of 1.00 mm thick steel sheet fixed to walls incl rawl plugs, drilling etc complete incl taking down old wooden plate rack complete all as specified and as directed by the Engineer-in-Charge.
S&F in repairs brass chromium plated sink mixer with regular spinning spouts suitable for kitchen ( wall mounted model with connecting legs/wall flanges) of Model ARI-39309 of Jaquar complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair CP stop/angle valves, cast copper alloy, fancy type, chromium plated with long shank & cup with crutch or butterfly handle, screwed both ends for iron pipe of 15 mm bore complete all as specified and directed by Engr-In-Charge.
S&F in repair CP bib taps long body, cast copper alloy, fancy type with wall flange, chromium plated, screwed down to iron pipes or for brass ferrule of 15 mm bore complete all as specified and directed by Engr-In-Charge. (Hindware Cat F360004SCP or equivalent in Jaquar/Prayag )
S&F In repair Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair for brass CP towel rail of 15mm dia with hook 600mm long complete all as specified and directed by Engr-In-Charge.
S &F in repair Toilet paper holder with flat recessed type stainless steel complete all as specified and directed by Engr-In-Charge.
S&F as in repairs, liquid soap dispenser with stainless steel metallic bottle complete all as specified and directed by Engineer-in-Charge.
Dismantling of old PVC water tank & S&F rotational moulded polythene water storage tanks in double layer (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I of capacity 1000 ltrs including making connection with fitting for inlet & outlet pipe complete all as specified and directed by the Engineer-in-Charge.
S&F PTMT ball valves high pressure with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe of 25mm dia complete all as specified and directed by the Engineer-in-Charge.
Dismantling of old PVC water tank & S&F rotational moulded polythene water storage tanks in double layer (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I of capacity 500 ltrs incl making connection with fitting for inlet & outlet pipe complete all as specified and directed by the Engineer-in-Charge.
S&F in repair, gun metal globe or gate valves with iron wheel head, screwed both ends for iron pipe and fixed for 20 mm dia pipe (ISI Marked) complete all as specified and directed by the Engineer-in-Charge.
S&F in repair hand dryer in rugged multiple stoved, multiple grounded steel enclosure with one bracket for firm wall fixture having features of No touch operation, solid state time delay to allow user to keep hands in comfortable position complete all as specified and directed by the Engineer-in-Charge.
S&F in repairs for white vitreous china battery based infrared sensor operated urinal of size 295 x 325 x 575 mm having water inlet from back side, including fixing to wall with suitable brackets and sensor all as per manufacturers specification and direction complete all as specified and directed by the Engineer-in-Charge. . (Make: Hindware - Flow with integrated sensor CAT No 60021or equivalent in Jaquar/Parryware)
M&L for reinforced cement concrete 1:2:4 type B-1 using 20 mm graded aggregate (nominal mix ) in slabs, shelves supported on walls, beams and columns in floor, roofs, canopies and in shelves and the like complete all as specified and directed by the Engineer-in-Charge.
Form work to soffits of suspended slabs as roof slabs, floor slabs, landings and similar work n.exc 200mm thick for rough finished surfaces complete all as specified and directed by the Engineer-in-Charge.
Demolition of reinforced cement concrete in any situation / thickness such as slabs / shelves etc including cutting of reinforcement to facilitate demolition complete all as specified and directed by the Engineer-in-Charge.
S&F mild steel framed work as angle iron, flat iron, square/rectangular hollow pipes, plain plates of any thickness, channels and similar item of works as in roof cladding etc, mild steel work confirming to Gde Fe-410 complete all as specified and directed by the Engineer-in-Charge.
S&F fibre glass reinforced translucent corrugated 2 mm thick sheets with two corrugation side lap fixed with coach screws and washers in curved roof complete all as specified and directed by the Engineer-in-Charge.
Dismantling of wood/ aluminium partition of any type with glass/board panels and removing from site complete all as specified and directed by the Engineer-in-Charge.
Fixing only of safe/Almirah made of iron/steel or of any specification/size in the cavity of wall/partition made as per requirement at site complete all as specified and as directed by the Engineer-in-Charge.
S&F in repair PVC (SWR) pipes of 200 mm bore, single socketed in any length with rubber ring joints laid in trenches, floors or fixed in walls complete all as specified and directed by the Engineer-in-Charge.
Dismantling brick work including quoins, arches, pillars etc built in cement mortar complete all as specified and directed by the Engineer-in-Charge.
M&L brick work using sub class 'B' bricks straight or curved on plan exc 6.00 m mean radius built in CM 1:6 complete all as specified and directed by the Engineer-in-Charge.
Taking down carefully all wall storage unit made up of particle board or of any other material/ description any size after completion of necessary repair work and re fixing the same on same or other locations with necessary fasteners, screws, wooden gutties required for the work as directed at site by the Engineer in charge complete.
Removing building materials etc. (other than spoil payable under items 03028 to 03031 in Section-3—Earthwork) to a distance of 100m or under, beyond the lead included in the rates, including loading, unloading and stacking at the destination complete all as specified and directed by the Engineer-in-Charge.
Dismantling loose concrete cover of RCC columns, beams, slabs chajjas and the like as directed, roughening and cleaning concrete surface with steel wire brushes, washed with water and allowed to dry, including derusting of steel reinforcement, providing fabric mild steel wire mesh 75 mm x 75 mm x 2 mm dia as reinforcement to concrete. After placing the additional reinforcement all concrete surfaces shall thoroughly scrubbed with brushes, washed with water and alloy to dry . To this surfaces apply chemical polycrete admixture at the rate not less than 2% by weight of cement and providing minimum 30 mm thick (average thickness ) guniting mix (using 1 part of ordinary Portland cement 53 Grade and 2 parts of ghaggar sand mixed with adhesive / admixture at the rate as directed) with a pressure of 2 to 2.5 Kg per Sq cm by guniting machine and surfaces finished even and fair, including necessary padding, shuttering / form work , Including 5 mm thick cement plaster in CM (1: 4 ) complete all as specified and directed by Engineer - in -charge. Note:- (a) The rate is inclusive for scaffolding or required necessary arrangement for multi-storey bldg external guniting.
M&L for Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P. brass/ stainless-steel screws, handle , lock, hinges, tower bolt all complete as per architectural drawings and the directions of Engineer-in-Charge.
Supply and fixing 4.8 mm thick ordinary quality sheet glass exc 0.5 sqm in each pane of glazing with oil putty /beading etc. complete all as specified and directed by Engineer-in-Charge.
M&L pre-laminated particle board 12mm thick, interior grade, pre-laminated both side with decorative choice lamination and other side balancing white lamination,fixed with screws to timber frame work complete all as specified and directed by Engr-In-Charge.
Demolition of raised platform of cement concrete of any description/ type, earth filled in raised platform complete all as specified and as directed by the Engineer-in-Charge.
INTERNAL ELECTRIFICATION :- Taking down carefully copper/aluminium point wiring light ,fan, light fittings,socket or power complete, such as switches, ceiling roses, pendents, regulators, sockets etc.removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per condition separately) and making good disturbed surface of walls, floors etc. complete all as specified and directed by Engineer-in-Charge.
M&L for point wiring for one light point/fan point controlled by one SP switch with single core PVC insulated unsheathed 1100 volt grade cable with multi strand copper conductor of size 1.5 Sq mm FRLS (Nominal area) drawn through and including non metallic rigid PVC concealed conduit, medium grade, ISI marked not less than 20mm dia, concealed in wall, ceiling with GI saddles GI screws, rawl plugs (concealed conduit wiring) with all fittings including Tee, Junction boxes and provision of pressed steel terminal modular box powder coated of suitable size for mounting switch sockets and regulators and drawing continuous earth wire of PVC insulated unsheathed 1100 Volts grade cable with stranded copper conductor of size 1.5 Sq mm (Nominal area) complete all as specified and directed. Note: Cost for cutting, chasing and making good to existing surfaces are deemed to be included in the Quoted Rate.
All as per item No-79 above but for one 3 pin socket out let, 6 Amps on same board with the cable 1.5 Sqmm size complete all as specified and directed.
All as per item No-79 above but for one 3 pin socket out let, 6 Amps on Independent board with the cable 1.5 Sqmm size complete all as specified and directed.
All as per item No 79 above but with 2.5 Sq mm cable for Independent board one 3 pin 15 Amps socket outlet including single core 2.5 Sq mm PVC insulated copper conductor unsheathed 1100 V grade IS -694 FR LS cable for continuous earth wire required size all as specified and directed by Engineer-in-Charge.
S&F modular switch, 5/6 Amps , 1 module one way complete all as specified and directed. Make : Crabtree / Legrand / Havells
S&F modular socket outlet , 6 Amp, 2/3 pin combined, 2 module complete all as specified and directed. Make : Crabtree/Legrand/Havells
S&F modular Switch, 16 Amps,1 module,complete all as specified and directed. Make : Crabtree / Legrand / Havells
S&F modular socket outlet , 6/16 Amp, 2/3 pin combined, 2 module complete all as specified and directed. Make : Crabtree/Legrand/Havells
S&F in repairs modular white cover plate with frame 2 module complete all as specified and directed. Make Roma/MK/Legrand
S&F in repairs modular white cover plate with frame 3 module, complete all as specified and directed. Make Roma/MK/Legrand
S&F in repairs modular white cover plate with frame 4 module, complete all as specified and directed. Make Roma/MK/Legrand
S&F in repairs modular white cover plate with frame 8 module, complete all as specified and directed. Make Roma/MK/Legrand
S&F in repairs modular metal flush box frame 2 module, complete all as specified and directed. Make Roma/MK/Legrand
S&F in repairs modular metal flush box frame 3 module, complete all as specified and directed. Make Roma/MK/Legrand
S&F in repairs modular metal flush box frame 4 module, complete all as specified and directed. Make Roma/MK/Legrand
S&F in repairs modular metal flush box frame 8 module, complete all as specified and directed. Make Roma/MK/Legrand
Supply and fixing of ceiling roses, surface bakelite 65x50mm 2 or 3 terminals, PVC / Polycarbonate, isolated body fixed on PVC round block complete all as specified and directed by Engineer-In- Charge.
Supply and fixing in repair wall mounted LED batten extruded aluminium heat shrink provided for efficient heat dissipation and integrated electronic driver, 20 watt LED fitting, 4000K , 230 Volts, diffused optics ,etc complete with all accessories , connecting up with twin core twisted flexible copper conductor cable from ceiling rose to fitting, and testing complete all as specified and directed by the Engineer- In- Charge.
Supply and fixing in repair wall mounted LED batten extruded aluminium heat shrink provided for efficient heat dissipation and integrated electronic driver,10 watt LED fitting with 100 lumen/watt, 6000K , 230 Volts, diffused optics ,etc complete with all accessories , connecting up with twin core twisted flexible copper conductor cable from ceiling rose to fitting, and testing complete all as specified and directed by the Engineer- In- Charge.
Taking down unserviceable submain wiring of alluminium of any size cable including batten / conduit complete etc and making good disturbed surfaces complete all as specified and directed.
M & L for submain wiring with three run of 10 sqmm single core PVC insulated but unsheathed FRLS cable of specified size of multistranded copper conductor 1100 volts grade IS:694 marked and one run of 6 sqmm PVC insulated but unsheathed FRLS cable for earth continuity conductor drawn through and under suitable size of rigid non metallic PVC conduit , medium grade, ISI marked ( not less than 20 mm dia) complete with all acessories and fittings all laid / fixed concealed in wall / ceiling or surface in wall and surface conduit on ceiling, and also include the specified runs of specified size earth continuity conductor of similar type cable complete all as specified - 2 Runs of 10.0 Sqmm single core and one run of 6.0 sqmm single core cable.
M & L for submain wiring with three run of 6.0 sqmm single core PVC insulated but unsheathed FRLS cable of specified size of multistranded copper conductor 1100 volts grade IS:694 marked and one run of 6.0 sqmm PVC insulated but unsheathed FRLS cable for earth continuity conductor drawn through and under suitable size of rigid non metallic PVC conduit , medium grade, ISI marked ( not less than 20 mm dia) complete with all accessories and fittings all laid/ fixed concealed in wall /ceiling or surface in wall and surface conduit on ceiling, and also include the specified runs of specified size earth continuity conductor of similar type cable complete all as specified - 2 Runs of 6.0 Sqmm single core and one run of 6.0 sqmm single core cable.
M & L for submain wiring with three run of 4.0 sqmm single core PVC insulated but unsheathed FRLS cable of specified size of multistranded copper conductor 1100 volts grade IS:694 marked and one run of 4.0 sqmm PVC insulated but unsheathed FRLS cable for earth continuity conductor drawn through and under suitable size of rigid non metallic PVC conduit , medium grade, ISI marked ( not less than 20 mm dia) complete with all accessories and fittings all laid / fixed concealed in wall / ceiling or surface in wall and surface conduit on ceiling, and also include the specified runs of specified size earth continuity conductor of similar type cable complete all as specified - 2 Runs of 4.0 Sqmm single core and one run of 4.0 sqmm single core cable
Taking down old unserviceable MCB DB SPN of any size complete all as specified and directed..
Supply and fixing MCB distribution board with bus bar 200A neutral link, earth bar made out of CRCA mild steel sheet surface mounting SPN 8 way 230 volts double door type regal gray horizontal type complete all as specified and as directed by Engineer-in-Charge. Note :- MCB shall be measured and paid separately.
Supply and fixing load line vertical distribution board 'A' frame made out of CRCA sheet, double door, surface mounting TPN 8 way 415 volts 200 Amps rated bus bar and stove enamelled dust and vermin proof suitable for MCCB as incomer and MCCB 250 amps as outgoing complete all as specified and as directed by Engineer-in-Charge and including MCCB 250 amps )
Taking down unserviceable SP / SPN /TPN MCBs of any capacities from the MCCB DBs / MCB DBs after disconnecting the electric supply complete all as specified and directed.
S&F MCB SP 6 to 32 Amps 10 KA, 240 volt all as specified and directed by engineer-in-charge.
S&F MCB SPN 40 Amps 10 KA, 240 volt 50 Hz all as specified and directed by engineer-in-charge.
Supply and fixing MCBs 10 KA breaking capacity, triple pole, and neutral, 240 volts, 40 to 63 amps complete all as specified and directed.
Supply and fixing in repair LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
Supply and fixing in repair recess mounting led backlit round downlighter of 18 Watt made out of PDC AL with high efficient LED's & glare free opal diffuser , IP 20 suitable for roof ceiling including connecting up with driver three core flexible copper conductor cable of suitable size complete all as specified and directed.
Taking down old exhaust fan complete from the site and depositing to MES store yard complete all as specified and as directed
Supply and fix in repair LED COB down lighter adjustable recess mounting LED round tiltable of 6 Watts made of PDC AL with high efficient COB LED 06 Watt and clear diffuser IP-20 complete all specified and directed.
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, copper winding of sweep 250 mm complete all as specified and directed by Engineer-in-Charge.
S & F in repair of MCCB 3 pole 415 V, adjustable type 200 amps with breaking capacity of 16 KA all as specified and directed by Eng in charge.
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 300 sq mm 3.5 core including taking out of old unserviceable cables complete all as specified and directed by Eng in charge.
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core including taking out of old unserviceable cables complete all as specified and directed by Eng in charge.
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 3.5 core including taking out of old unserviceable cables complete all as specified and directed by Eng in charge.
Supply and fixing in repair of new cablofil wire mesh cable tray electro zinc (EZ) hot dipped galvinised size 54(h)X300 (w) mm manufactured from steel wires welded together with coupler and longitudinal T-welded safety edge and fixed in roof /RCC slab with the suitable length of fasteners at suitable intervals according to site requirement complete all as specified and directed. Make: Legrand / ABB / Schneider
FIRE DETECTION SYSTEM :- Taking down of existing smoke detector carefully without disturbing existing fire detection system any type and removing from site with all connections and keeping in safe custody for refixing or giving credit to the contractor complete all as specified and directed.
Re-fixing of smoke detector received from Sr Item No 119 above with accessories and fittings complete all as specified and directed by Engr-in-Charge.
Supply, installation, testing and commissioning of en list conventional photoelectric / optical smoke detector, the smoke by a couple of infrared diodes. The principle of detection is granule in the smoke can reflect infrared light, in order to reduce the interference and lower power consumption, the emitting circuit adopts the pulse signal. The operating temperature should not be more than 10 degree celsius + 50 degree Celsius. The product in accordance with the networking approach is divided into- 2-wire and 4-wire detectors complete all as specified and directed by engineer-in- charge". Note: Smoke detector should be compatible with the existing fire alarm system.
Supply, installation and commissioning of response indicator for detector on false ceiling all as specified and directed.
Supply, fixed to wall or to drawn through conduit PVC insulated and sheathed cable 2 core x 1.5 sq mm. stranded copper conductor,aluminium mylar tape shielded FRLS wire in draw through conduit complete all as specified and directed.
Supply and laying of 20mm Dia rigid steel conduit fixing on wall / roof / ceiling etc including concealed in wall and securing with proper saddle and making good disturbed surface and wall finishing (For Fire Detection) all accessories complete all as specified and directed by Engineer-in-Charge.
Taking down of existing MCP and refixing of same red manual Conventional Call point with LED and Resistor 470 OHM Flush Mounting Flexi Element complete all as specified and directed by Engr-in-charge.
Taking down of existing and refixing of same Conventional HOOTER cum Strobe Flush Mounting Flexi Element complete all as specified and directed by Engr-in-charge.
Taking down of existing fire alarm panel carefully and to be kept in safe custody until completion of finishing work and refixing and commissioning of same Conventional FIRE ALARM PANEL with all electrical connection with all devices of fire alarm system complete after completion of all as specified and directed by Engr-in-charge.
AIR CONDITIONING :- Supply, install, commissioning and testing of commercial Air curtain unit for prevention of dust and conditioned air losses, single phase,220 V, 50 HZ, made out of MS/CRCA sheet of minimum thickness 18 gauge finished with two coats of red oxide primer and final coat of synthetic enamel paint (oven baked) with MS - CRC 18 gauge square perforated suction grills, Aluminium alloy fans and single phase electric motor, nozzles etc, complete with fittings and accessories so as to produce 1 - 1.5 m/sec air velocity at floor level for door opening size 70'' x 78 '' including dismantling old unit complete all as specified and directed by Engineer-in-charge.
Taking down and refixing of tower Type AC 4.0 TR including connected accessories like refrigerant tubing stand electric cable etc complete, all as specified and directed by Engineer-in-Charge.
Taking down and refixing of split Type AC 1.5/2.0 TR including connected accessories like refrigerant tubing stand electric cable etc complete, all as specified and directed by Engineer-in-Charge.
S&F unplasticised PVC pipe 25 mm dia of pressure rating 10 kg/cm2 fixed complete to walls, ceilings or in floors etc. including accessories, clamps and fasteners complete all as specified and directed by Engineer-in-charge
Supply and laying in replacement of refrigerant line copper tubing with insulation of size 5/8" with clamping on wall surface or concealed with both the ends connection as in repair complete all as specified and directed by Engineer-in-charge.
Supply and laying in replacement of refrigerant line copper tubing with insulation of size 3/8" with clamping on wall surface or concealed with both the ends connection as in repair complete all as specified and directed by Engineer-in-charge.
Supply and laying in replacement of refrigerant line copper tubing with insulation of size 1/2" with clamping on wall surface or concealed with both the ends connection as in repair complete all as specified and directed by Engineer-in-charge.
Supply and laying in replacement of refrigerant line copper tubing with insulation of size 1/4" with clamping on wall surface or concealed with both the ends connection as in repair complete all as specified and directed by Engineer-in-charge
S&F in replacement of unserviceable PVC insulated and PVC round sheathed with stranded copper conductor (flexible) industrial cable 1100 volts conforming to IS-694 of size 4.0 sqmm 3 core complete all as specified and directed.
M&L in replacement of cross arms bracings supports , clamps and back plates fabricated from structural steel sections including nuts bolts washers welding bending cold or hold drilled holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat one under and one finished coat of paint for installation of condensing unit on the wall / ground complete all as specified and directed by Engineer-in-charge.
M&L for addition / alteration in the existing SA/RA GI sheet metal ducts made of GI sheet of Class -VIII as per IS -277 of following thickness for supply air ducting as per IS - 655 and as required by the specifications and complete all as specified and directed.
24 gauge galvanised sheet steel
22 gauge galvanised sheet steel
20 gauge galvanised sheet steel
Supply, fabrication, installation and testing the flexible connections constructed of fire resistant double resin sleeve complete all as specified and as directed by Engineer-in-charge.
Supply, fabrication, installation and testing in replacement the grills / Diffusers for Supply Air made of extruded Aluminum section with control volume powder coated paint and GI VCD complete all as specified and as directed by Engineer-in-charge.
Supply, fabrication, installation and testing in replacement the grills / Diffusers for Return Air made of extruded Aluminum section with control volume powder coated paint complete all as specified and as directed by Engineer-in-charge.
Supplying, fixing, testing and commissioning in replacement of power coated extruded aluminium section of 120 G thick for fresh air grill in weather maker room with volume control dampers, bird screen etc complete all as specified and directed.
Supply, installation, testing and commissioning of motorised combined fire damper made of 20 G GI sheet complete with control panel, inter connecting wiring at specified location complete all as specified and directed for following:
Fire Dampers.
Actuators
Control Panel & Wiring
Supply installation, testing and commissioning of acoustic insulation of SA Duct in AHU Rooms as shown on drawing with 25 mm thick resin bonded fibre glass, of 32 kg/cum density, covered with tissue paper and 26 G Aluminium perforated sheet complete all as specified and directed..
Supply installation, testing and commissioning of thermal insulation of Duct with 13 mm thick Aluminium foil faced Closed Cell XPE Foam insulation complete all as specified and directed.
SPECIAL WORK :- S&F 15mm thick Toughened glass as in floor hinged, partitions, sliding doors, automatic doors and similar work of approved brand and manufactures, including cutting to shape, drilling holes required with read frame work as per manufacture direction, floor wall locking arrangement, complete all as specified and directed by Engr-in-Charge. Note:- Quoted Rate shall be deemed to include for all necessary fittings and frame work for glass fitting, provision of top and bottom pivots, S/S handle, hinges, double action floor spring, stoppers etc. complete all as specified and directed by Engr-in-Charge.
Hindustan Co.Co (BID ID -3087420)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .