Executive Engineer University of Kashmir
Construction Division
Electric Works and Supply fixing and Testing of 2KVA Inverter for Physio Centre of Directorate of Physical Education and Sports.
2022_UDJK_165689_1
F(E.Tend)(UCD)/KU/110/21
Open Tender
Electrical and Maintenance Works
Item Rate
45 days
Main Campus
As per NIT
3 documents required · 3 mandatory
₹200
Registrar University of Kashmir
Exempted
15 Apr 2022
31 Mar 2022
15 Apr 2022
31 Mar 2022
12 Apr 2022
31 Mar 2022
120 days
Amount
(Part A) Electric works
Supply of ISI marked aluminium conductor XLPE insulated cable (of approved make as directed by EIC) as per IS 7098, un armoured, served, sheathed 1100 volts grade. 70 sqmm 3.5 core
Supplying and making end termination with brass compression glands of following sizes of 1.1. kv grade multicore aluminium conductor PVC insulated and PVC sheathed 4 X 70 sq. mm (38mm)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable (of approved make as directed by EIC) of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. Above 35 sq. mm and upto 95 sq. mm
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C”-curve, miniature circuit breaker suitable (of approved make as directed by EIC) for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. .(of approved make as directed by EIC) single pole
Providing and fixing of 63 Amp, 10kA, C-Curve D/P MCB along with enclosure of required size (of approved make as directed by EIC)
Providing and fixing of 12 way Double door distribution Board (of approved make as directed by EIC)
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed in class heavy duty PVC conduit as required including conduit 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire (for AC)
2 X 16 sq. mm + 1 X 16 sq. mm earth wire
Providing and fixing of Heating points using 4 sq.mmPVC insulated copper wire of FRLS through 1” 2mm PVC conduit/1” PVC casing capping and providing and fixing of 6/16 Amp. of Modular Switch/socket recessed in wall covered with modular sheet/ MS box of required size including providing and fixing of 4mm² PVC insulated copper wire as earth wire, point taken up to D.B. duly tested and commissioned, complete point in all aspects including conduit
Providing and fixing of Computer point/ TV/ inverter point with 2.5 sq. mm PVC insulated copper wire through PVC Conduit pipe/ PVC channel with all necessary accessories i/c 6Amp switches, 5 Amp 3-pin socket 2 nos. of (of approved make as directed by EIC) recessed in wall covered with Modular Plates i/c Modular Box of required size i/c 2.5 sq.mm PVC Insulated copper wire of FRLS (as earth wire, Point taken up to DB duly tested and commissioned (in loop 3 circuit) including conduit
Providing/fixing of LED slim 12-15 watt 230V Downlighter Recessed/ Surface mount aluminium diecast complete in all respects. (of approved make as directed by EIC)
Providing/ fixing of 20 Amp switches socket combined Box/recess type of (standard) make as directed by EIC
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
(Part B) Supplying Fixing, testing and commissioing of 2 KVA Inverter
Supply, installation, testing & commissioning of 2 kVA 1 phase Inverter with 2x180AH 12V tubuler Batteries including input/output leads/ Switch sockets etc. to make the system operational. with trolley Inverter (of approved make as directed by EIC) Battery (of approved make as directed by EIC) Note: Item Should have minimum of two years Warrenty and free service.
M/S WANI ELECTRIC AND MECHANICAL ENGINEERS
stage.html
html • 0.02 MB
finance_384171.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .