| 3 | L3₹7.1 L+₹77,863 (12.2%)Rejected-Finance | L3 | Rejected-Finance Not being lowest |
Tender Value
₹7.5 L
EMD Value
₹15,000
Closing Date
15 Dec 2020, 6:00 pmClosed
GE 970 EWS
GE 970 EWS c/o 56 APO
REPAIR AND MAINT OF BLDG STREET LIGHT FITTINGS AND SUMMER WINTER APPLIANCES AT HAFT CHINAR TATTOO GROUND AND SONAMARG UNDER GE 970 EWS
2020_MES_383380_2
GE 970 EWS- /2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Tatto Ground and Sonamarg
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE 970 EWS
₹15,000
Yes
11 Feb 2021
21 Nov 2020
17 Dec 2020
21 Nov 2020
15 Dec 2020
1 Dec 2020
Amount
Taking down ceiling fan any size or sweep after disconnecting, dismantling and removal to trade workshop for repair, complete all as specified and directed.
M&L for opening the unserviceable/burnt fan 1200/1400 mm sweep and cutting of old burnt copper winding and rewinding the same with super enamelled copper winding wire of suitable gauge including insulating material such as paper cotton sleeves, varnish, reassembling, testing and connecting for satisfactory run, complete all as specified and directed by Engr-In-Charge
Supply and fixing in repair of ball bearing of the ceiling fan (any sweep) as per existing size incl greasing/oiling, complete all as specified and directed by engr-In-Charge. Make:- SKF/ NBC or Equivalent
Supply and fixing in repair of gun metal bushes of surface size for ceiling fan incl necessary mechanical work, complete all as specified and directed by Engr-In-Charge.
Supply and fixing of flexible cable, three core 0.5 Sqmm PVC insulated copper conductor cable for connecting ceiling fan, complete all as specified and directed. Make:- Plaza, Havells .
Supply and fixing in repair capacitor of of 2.5 MFD for ceiling fan, complete all as specified and directed by engr-in-Charge.
Supply and fixing in repair of ceiling fan blade set of three, heavy duty suitable for 1200/1400mm sweep of as per existing make as direcetd by Engr-in-Charge.
Supply and fixing in repair of PVC canopy for ceiling fan 1200/1400mm sweep complete for existing various makes/model of fan, complete all as specified and directed by Engr-in-Charge.
M&L for disconnecting and taking down exhaust fan and blades any size or sweep after dismantling and removal to trade workshop for repair, complete all as specified and directed.
M&L for strip opening and cutting of old burnt copper winding of exhaust fan and rewinding of exhaust fan motor of sweep 450mm with super enamelled copper winding wire of suitable gauge including insulating material such as paper cotton sleeves, varnish, re-assembling, testing and connecting for satisfactory run, complete all as specified and directed as specified and directed by Engr-in-Charge.
All as per srl item No. 10 here-in-before, but 300mm sweep.
Supply and fixing in repair capacitor of 4 Mfd for exhaust fan, complete all as specified and directed by Engr-in-Charge.
Supply and fixing in repair ball bearing of exhaust fan of any size/make as per the existing, complete all as specified and directed. Make: SKF/NBC or equivalent .
M&L for painting the exhaust fan including louvers of size 300/450mm sweep with two coats of synthetic enamel paint after cleaning and making the surface of oil/dust free, complete all as specified and directed.
M&L for servicing of geyser by disconnecting the electric and water supply connections, dismantling the geysers of any size, type & capacity and opening the top and bottom cover, thermostat, heating element, safety valve, vent pipe, separating inner & outer tank, removing glass wool insulation complete and keeping aside for re-use after de-scaling of inner tank by liquid chemical and with pressure water jet and assembling back the geyser including re-installation on wall with studs, nuts & bolts complete and testing after reconnecting electric and water connections, complete all as specified and directed.
Supply and fixing in repair heating element for geyser of cap 1.5KW, AC 230 Volts, 50 Hz (as per sample), complete all as specified and directed. Make:- Micron/ Bajaj/ Havells
Supply and fixing in repair Heating element for geyser of cap 2.0KW, AC 230 Volts, 50 Hz (as per sample), complete all as specified and directed. Make:- Micron/ Bajaj/ Havells
Supply and fixing in repair thermostat for Geyser of capacity 25/35/50 ltr (long size) with temperature setting adjustment range from 40 to 85°C, ISI Marked, complete all as specified and directed. Make:- Philips/ Bajaj/ Venus
Supply and fixing in repair geyser syphon assembly Set suitable for 25 ltr capacity geyser, fixed in replacement, as per existing complete all as specified and directed by engr-in-Charge.
All as per item Srl No. 19 above but for 35 Ltr capacity.
All as per item Srl No. 19 above but for 50 Ltr capacity.
M&L rubber gasket for water heater storage type of any capacity fixed, in replacement and suitable as per the existing, complete all as specified and directed
Supply and fixing PVC sheathed three core copper conductor flexible wire of size 2.5 Sqmm for connecting geyser, complete all as specified and directed. Make:- Finolex/Polycab/L&T
Supply and fixing in repair Sheet Metal Enclosure with socket, plug top and MCBs single pole and neutral enclosures with a two pin and earth plug and socket complete with one single pole MCB 20 Amps 240 Volts, complete all as specified and directed. Make: Standard/Havells/Schnider
Supply and fixing in repair of safety valve for geyser of 25/35/50 litre capacity, as per existing make complete all as specified and directed
Supply and fixing in repair of non return valve 15mm dia for geyser of 25/50 litre capacity, complete all as specified and directed.
Supply and fixing of heavy duty PVC connector 600mm long 15mm dia with PTMT nut for geyser of 25/50 litre capacity, complete all as specified and directed. Make: Paryag/Venus or equivalent.
M&L for disconnecting and taking out geyser of capacity 15/25 litre and replacement of copper/SS inner tank and refilling of glass wool, refixing, connecting and testing, complete all as specified and directed by engr-in-Charge.
All as per item Srl No. 28 above but for 35 Ltr capacity.
All as per item Srl No. 28 above but for 50 Ltr capacity.
M&L for preparation of surface of Geyser of capacity 25/35/50 Ltr by scarping, removing old paint etc and applying two coats of synthetic enamel paint over one coat of red oxide primer,complete all as specified and directed.
Supply and fixing of geyser Bolt 100 mm long with nut & washers, complete all as specified and directed
Taking out the burnt/ unserviceable compressor from the refrigerator of 165 to 200 ltr capacity and supply & fixing the same as per the existing complete all as specified and directed.
M&L servicing and overhauling of refrigerator of 165 to 200 ltr capacity of various make and model incl transporting to workshop & back complete all as directed.
Supply and fixing in repair of thermostat for refrigerator of 165 to 200 ltr capacity.
Supply and fixing in repair of thermal relay for refrigerator of 165 to 200 ltr capacity.
M&L for Charging refrigerant R134A and testing for proper cooling and leakage complete for refrigerator of 165 to 200 ltr capacity all as specified and directed.
Taking out the burnt/ unserviceable compressor from the refrigerator of 210 to 335 ltr capacity and supply & fixing the same as per the existing make complete all as specified and directed.
M&L servicing and overhauling of refrigerator of 210 to 335 ltr capacity of various make and model incl transporting to workshop & back complete all as directed.
Supply and fixing in repair of thermostat for refrigerator of 210 to 335 litre capacity.
Supply and fixing in repair of thermal relay for refrigerator of 210 to 335 litre capacity.
M&L charging refrigerant R134A and testing for proper cooling and leakage complete for refrigerator of 210 to 335 ltr capacity all as specified and directed.
Taking out the burnt/ unserviceable compressor from the deep freezer of 210 to 400 ltr capacity and supply & fixing the same as per the existing complete all as specified and directed.
M&L for servicing and overhauling of deep freezer of 210 to 400 ltr capacity of various make and model incl transporting to workshop complete.
Supply and fixing in repair of thermostat for deep freezer of 210 to 335 litre capacity.
Supply and fixing in repair of thermal relay for deep freezer of 210 to 335 litre capacity.
M&L for Charging refrigerant R134A and testing for proper cooling and leakage complete for deep freezer of 210 to 400 ltr capacity all as specified and directed.
M&L for disconnecting the electric supply from the mains, transporting the window/split type air conditioner capacity 1.5/2.0 ton from original location to workshop to carry out the servicing complete and re-fixing at the original position after repairs and making the ACs fully functional and testing for satisfactory working, complete all as specified and directed.
Taking out old burnt/unserviceable compressor from the air conditioner 1.5/2.0 ton capacity and replacing the same as per the existing, re-fixing in position incl testing satisfactory working complete all as directed.
M&L for charging refrigerant gas R134A in 1.5/2.0 ton capacity window /Split type air conditioner complete including testing for satisfactory working after flushing out and cleaning the surface with nitrogen gas for checking the leakage, complete all as specified and directed.
Supply and fix in repair blower motor suitable for 1.5/2.0 ton capacity air conditioner all as directed.
Supply and fix in repair thermostat suitable for 1.5/2.0 ton capacity air conditioner all as directed.
Supply and fix in repair of relay suitable for 1.5/2.0 ton capacity air conditioner, complete all as directed.
Supply and fix in repair of running condenser 36 Mfd, complete all as directed.
Supply and fix in repair of starting condenser 100/120 Mfd, complete all as directed.
M&L for repair to unserviceable/burnt stabilizer of 3 KVA to 5 KVA capacity, rewinding the same with super enamelled copper winding wire of suitable gauge including insulating material such as paper cotton sleeves, varnish, reassembling, replacement of knobs, LED's etc. and making fully functional on load as connected to Refrigerator/Deep freezer/AC complete all directed.
All as per item Srl No. 56 above but for capacity 0.25 to 1 KVA .
M&L for Dismantling the complete fuel injector pump of water heating plant of various capacity upto 2000 ltrs, transporting to trade workshop for repairs and complete servicing and refixing the same after satisfactory repairs, reinstallation, testing and commissioning complete, all as specified and directed.
Material and labour for calibration and complete repair of fuel injection pump of water heating plant of various capacity upto 2000 ltrs, on work bench for fine spray and machining work and refixing the same for satisfactory functioning, complete, all as specified and directed.
Supply and fix in repair nozzle of hot water plant as per existing size complete all as specified and directed.
Supply and fix in repair pressure meter suitable for hot water generator as per existing size complete all as specified and directed.
Supply and fix in repair fuel filter suitable for hot water generator as per existing size complete all as specified and directed.
Supply and fix in repair solenoid switch for hot water generator as per existing size complete all as specified and directed.
Supply and fix in repair burner gasket suitable for hot water generator as per existing size complete all as specified and directed.
Supply and fix in repair photo ignition transformer suitable for hot water generator/plant as per existing size and testing after repairs complete, all as specified
Supply and fix in repair indicator assembly, complete all as specified
Supply and fix in repair bimetallic overload relay 4.0 - 6.5 Amps type ML complete all as specified
Supply and fix in repair electromagnetic rod combined with positive/ negative terminals suitable for hot water generator of any capacity as per existing size and testing after repairs complete all as specified and directed.
Supply and fix in repair photo censor suitable for hot water generator/plant as per existing size and make incl testing after repairs complete all as specified and directed.
Supply and fix in repair high pressure diesel/fuel pipe with internal and outer threads suitable for hot water generator/plant as per existing size incl testing after repairs complete all as specified and directed.
M&L for dismantling fuel tank of water heating plant, servicing, decarboning, cleaning, removing of of complete water plant and reassembling the same after cleaning properly by removing all deposited particles, dust, carbon etc, complete all as specified and directed.
Supply and fix in repair digital type electronic temprature gauge with thermostat control relay suitable for 2,00,000 K Cal/hr capacity hot water generator as per existing size and testing after repairs complete all as specified and directed.
M&L for disconnecting and taking out burntout hot water plant blower motor, transporting to workshop, dismantling carefully, cutting out burnt windings, cleaning the slots and rewinding with super enamelled copper winding wire of appropriate / exisitng gauge & weight incl all insulating materials, varnishing, drying, heating etc and incl replacement of ball bearings as per existing, reassembling and refixing at original site and testing, complete, all as specified and directed.
M&L for disconnecting existing defective 250 litre capacity heating plant/ Hamam from electric mains, water mains and fuel pump isolate the necked connections, removing from foundation by unsrew the nuts bolts etc discouple of pump and motor, opening of heating plant and motor for insoection in presence of Engr-in-Charge and to carry out major repair transporting to workshop and back for reassembling the heating plant /hamam after repairs refixing in postion and reconnection same as prior to removing from foundation including replacement of nut bolts washer etc of suitable size, testing and commissioning complete all as specified and directed. Disconnecting the heating plant and remove the SS inner and outer tank carefully and carry to trade workshop for following necessary repairs : (a) Cut the rust out parts of 250 ltr capacity heating plant. (b) moulding and welding of inner tank of 250 ltr capacity heating plant. (c) moulding and welding of outer tank of 250 ltr capacity heating plant. (d) supply and filling the glass wool between inner and outer tank. (e) supply and fixing in repair of upper and lower aluminium strap of suitable size. (f) supply and fixing in repair of necessary nut bolts and washers. (g) supply and fixing in repair of base plate along with GI plate of 5mm thick for 250 ltr capacity heating plant. (h) supply and fixing in repair of water connection arrangement of water heater plant i.e nipple, reducer, socket gate/ball valve etc. (i) Repair/replacement of top and bottom cover. (j) other miscellanious repair (k) supply and replacement of inner (dollaky) plates 5mm thick. (l) supply and replacement of vertical MS tubes size of 50 mm. NOTE : - Replacement of defected parts will be included or paid in this item. Major repairs are not possible at site, the heating plant /Hamam shall be shifted to civil workshop and cost of shifting and back to site included in this item.
M&L for disconnecting existing defective 500 litre capacity heating plant/ Hamam from electric mains, water mains and fuel pump isolate the necked connections, removing from foundation by unsrew the nuts bolts etc discouple of pump and motor, opening of heating plant and motor for insoection in presence of Engr-in-Charge and to carry out major repair transporting to workshop and back for reassembling the heating plant /hamam after repairs refixing in postion and reconnection same as prior to removing from foundation including replacement of nut bolts washer etc of suitable size, testing and commissioning complete all as specified and directed. Disconnecting the heating plant and remove the SS inner and outer tank carefully and carry to trade workshop for following necessary repairs : (a) Cut the rust out parts of 500 ltr capacity heating plant. (b) moulding and welding of inner tank of 500 ltr capacity heating plant. (c) moulding and welding of outer tank of 500 ltr capacity heating plant. (d) supply and filling the glass wool between inner and outer tank. (e) supply and fixing in repair of upper and lower aluminium strap of suitable size. (f) supply and fixing in repair of necessary nut bolts and washers. (g) supply and fixing in repair of base plate along with GI plate of 5mm thick for 250 ltr capacity heating plant. (h) supply and fixing in repair of water connection arrangement of water heater plant i.e nipple, reducer, socket gate/ball valve etc. (i) Repair/replacement of top and bottom cover. (j) other miscellanious repair (k) supply and replacement of inner (dollaky) plates 5mm thick. (l) supply and replacement of vertical MS tubes size of 50 mm. NOTE : - Replacement of defected parts will be included or paid in this item. Major repairs are not possible at site, the heating plant /Hamam shall be shifted to civil workshop and cost of shifting and back to site included in this item.
Supply and laying of XLPE under ground insulated, armoured, heavy duty LT 1100 volts 4 Sqmm 2 core grade cable with aluminium conductor ISI markedas per IS-70098 (Part-I), laid in trenches/pipes, fixed to poles/walls with suitable saddle & glands complete all as directed incl taking out the old burnt out cables all as specified and directed by Engr-in-Charge.
All as per item No. 76 above but 6 Sqmm 4 core.
All as per item No. 76 above but 25 Sqmm 4 core.
Excavation in trenches not exc 1.5 M wide and not exc 1.5 M in depth and getting out in soft/loose soil or hard/dense soil for taking up or laying of cable & electrical poles etc. complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cms complete all as specified and directed.
Removing surplus soil to a distance not exc. 50m and depositing where directed at a level n. exc. 1.5m above the starting point complete all as specified and directed.
Supply and laying dry river sand to be laid in 8 cms before laying of cable and 15 cms above cable in trenche as cable cushioning and covering complete all as specified and directed. Note: for payment purpose punned thickness shall be measured
M/L for brick well burnt locally available sub class 'B' laid over sand cushioning to cable in trenches keeping width of brick parallel to the length of cable complete all as specified and directed.
Supply and Fix in repair for street light fitting bracket made out of 32/40mm bore GI pipe, light grade, bend to shape, 1.2 metre long, fixed to pole/wall with and including two sets of clamps made out of flat iron of size 50 x 6 mm with bolts, nuts and washers, complete all connected accesories for fixing of GI bracket with pole including one coat of anti corrosive primer and two coats of aluminium paint, all as specified and directed.
S & F in repairs Thermoplastic Cable Junction Box/Distribution Board size 333 x 233 x 105 mm, IP 65 with metric knockouts for cable entry of size 10 to 25 sq mm, 2 core including fastening clamp with LT pole, box hinged cover with locking arrangements including with terminals TPN strip, with 01 No MCB SP 6A 'B' Serials complete all as specified and directed. Make: HENSEL or its equivalent as approved by GE.
Supply and fix in repairs galvanised iron tubes 50mm bore, light grade including all fittings fixed to wall, ceilings and or laid in floors/tenches/under road etc complete for cable protection all as specified and directed.
Material and labour for sub main wiring with two runs of single core PVC insulated (FRLSH) unsheathed copper conductor multistranded cable of size 2.5 sqmm 1100 volts grade drawn through in & including PVC conduit/casing caping of suitable size & 1.5 sqmm single core copper conductor multistranded PVC insulated (FRLSH) unsheathed cable earth wire continuity conductor fixed on pole for connection from junction box to light fittings / switch to top of the Over Head Water tank of height not more than 30 mtr from ground level complete all as directed by Engr-in-Charge. Note : (i) Two run of cable 2.5 sqmm and one run of 1.5 sqmm earth wire and one run of PVC casing caping/PVC conduit shall be measured and paid as one unit only. (ii)Phase should be Red / Yellow / Blue, neutral should be black and earthing wire should be green in colour
Supply and fixing in repair Sheet Metal Enclosure double door with socket, plug top and for MCBs triple pole and neutral enclosures with 200 Amps rated bus bar complete all as specified and directed. Make: Standard/Havells/Schnider
Material and labour for earthing complete with galvanised steel earth plate electrode 60cmx 60cmx 6.00 mm thick buried directly in ground (Earth pit not less than 2.25 metre below normal ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected and including GI strip 32mm x 6mm by means of GI bolts, nuts, check nuts and washers, earth plate surrounded by packed alternate layers of coal dust and common salt 15cm thick, all around top and bottom and watering pipe 40mm bore of GI pipe light grade with funnel and wire mesh and 50mm bore GI pipe light grade for protection of GI strip 32mmx6mm from top of earth plate upto test point (upto 7.5metre in length) connected with suitable size of GI nuts, bolts and washers all as shown in Electrical plate No. 3 of SSR Part-I, testing on completion including excavation/earth work in any type of soil/rock, PCC chamber (1:3:6) using 20mm graded stone aggregate and 50mm thick RCC (1:2:4) type B-1 cover slab reinforced with 8mm dia TMT steel bars @ 100mm c/c both ways with suitable handle for lifting arrangement & including formwork and MS frame using MS angle iron 25x25x3mm complete all as specified and directed. Note :- Earth pit shall be constructed 50cm from the side of excavation to avoid sinking of pit
Supply and Fix in repair Energy efficient LED street Light Luminaire 45 watts capacity comprises a die-cast aluminium housing IP-65 Bow with front toughened glass cover suitable for mounting bracket of 40mm bore GI pipe light grade complete with all accessories including lamp and 2 core copper connecting cable of size 2.5 sqmm from junction box to light fitting (Approx 5 Mtr) complete and fixed on existing pole bracket including taking down old fitting as directed. Make : Cat Part No. BRTFG 45W LED or equivalent make of Philips /CG/wipro .
M/S Noor Mohammad Shalla
M/s Lal Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .