| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.7 CrAccepted-AOC | ₹7.7 Cr Quoted ₹8.0 Cr | L1 | Accepted-AOC Being Lowest |
| 2 | L2₹9.1 Cr+₹1.1 Cr (13.8%)Rejected-Finance BAKRON KA WADA NEAR NEELAM CINEMA JODHPUR ROAD BALOTRA BARMER RAJASTHAN 344022 | BALOTRA | BARMER | RAJASTHAN | 344022 | ₹9.1 Cr+₹1.1 Cr (13.8%) | L2 | Rejected-Finance Being not lowest |
| 3 | L3₹10.9 Cr+₹3.0 Cr (37.2%)Rejected-Finance | ₹10.9 Cr+₹3.0 Cr (37.2%) | L3 | Rejected-Finance Being not lowest |
| 4 | Rejected-Technical 77 KAILASH PURI BIKANER RAJASTHAN PIN 334001 | BIKANER | RAJASTHAN | 334001 | - | - | Rejected-Technical Rejected due to the firm is not enlisted in a(iii) category and further bidder has not submitted experience for relevant work, As such firm does not qyalify as per NIT |
| 5 | Rejected-Technical | - | - | Rejected-Technical Rejected due to the firm is presently declared unenlisted by CESC, not enlisted in a(iii) category and further bidder has not submitted experience for relevant work, As such firm does not qualify as per NIT |
Tender Value
₹11.4 Cr
EMD Value
₹8.9 L
Closing Date
18 Nov 2023, 6:00 pmClosed
CE AIR FORCE, GANDINAGAR
CE AIR FORCE, GANDINAGAR, LEKHAWADA PATIA, CHILODA, GANDHINAGAR, 382042
PROVISION OF PAVEMENT WORK AND OTHER SERVICES FOR ENABLING OPERATIONS AT AIR FORCE STATION JAISALMER
2023_MES_621866_1
81216/E8
Open Tender
Civil Works
Lump-sum
365 days
GE (AF) JAISALMER
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹3,000
GE (AF) JAISALMER
₹8.9 L
Yes
19 Jan 2024
6 Oct 2023
20 Nov 2023
6 Oct 2023
18 Nov 2023
4 Nov 2023
6 Oct 2023 - 18 Oct 2023
Amount
NOTE: Schedule ‘A’ Part I to XI are under Ser No. 1.00 to 11.00 are Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.
Lump sum price worked out for Building / Structures as listed in Sch `A’ Part I.
Lump sum price worked out for Excavation & Earthwork as listed in Sch `A’ Part II
Lump sum price worked out for Internal Electrification as listed in Sch `A’ Part III
Lump sum price worked out for Internal Water Supply as listed in Sch `A’ Part IV
Lump sum price worked out for Rigid Pavements as listed in Sch `A’ Part V
Lump sum price worked out for Road/Path/Culvert as listed in Sch `A’ Part VI
Lump sum price worked out for Sewage Disposal as listed in Sch `A’ Part VII
Lump sum price worked out for Area Drainage as listed in Sch `A’ Part VIII
Lump sum price worked out for External Electrification as listed in Sch `A’ Part IX
Lump sum price worked out for External Water Supply as listed in Sch `A’ Part X
Lump sum price worked out for Airconditioning as listed in Sch `A’ Part XI
SCHEDULE `A' PART-XIII MISCELLANEOUS ITEMS OF WORK (Note for items 12 to 31 The contractor shall quote his rate for each of these items separately. The estimated rate is left blank since the same is not prepriced by MES)
EXCAVATION AND EARTHWORK
Earth work in excavation by mechanical means (Hydraulic excavator) means over areas(exceeding 30 cm in depth,1.50m in width as well as 10 Sqm on plan) including getting out in all kind soil complete as specified and directed by Engineer-in-Charge.
Earth work in excavation by mechanical means (Hydraulic excavator) means over areas(exceeding 30 cm in depth,1.50m in width as well as 10 Sqm on plan) including getting out in soft/ordinary rock complete as specified and directed by Engineer-in-Charge.
Earth work in excavation by mechanical means (Hydraulic excavator) means over areas(exceeding 30 cm in depth,1.50m in width as well as 10 Sqm on plan) including getting out in hard rock where blasting is probitited complete as specified and directed by Engineer-in-Charge. Note: Rock obtained from this item is taken to schedule of credit and to be removed by contractor outside MOD land at his own cost.
Rough excavation in sloping ground -hill side cutting by mechanical means (Hydraulic excavator) including getting out in all kind soil complete as specified and directed by Engineer-in-Charge.
Rough excavation in sloping ground -hill side cutting by mechanical means (Hydraulic excavator) including getting out in ordinary-soft rock complete as specified and directed by Engineer-in-Charge.
Rough excavation in sloping ground -hill side cutting by mechanical means (Hydraulic excavator) including getting out in hard rock, Blasting probihted, complete as specified and directed by Engineer-in-Charge. Note: Rock obtained from this item is taken to schedule of credit and to be removed by contractor outside MOD land at his own cost.
SEWAGE DISPOSAL
Construction of Septic tank 25 users complete all as specified and as shown on drawings.
Construction of Soakage well of size 1.20m dia and 3.0m effective depth complete all as specified and as shown on drawings.
RIGID PAVEMENTS
S&F Engineer plastic signage boards/link boards of standard size, both side with writings/signs/arrows with retro-reflective sheetings of approved type and colour,made of hard plastic or perplex sheet 4 to 5 mm thick of approved colour and type,duly framed in with aluminium strip suitable size as required,mounted up on adequate number of legs of minimum height of 3'6'' made out of specialised frangible material,weather proof, Bird proof elastic spikes on top of board suitable to withstand extreme cold,extreme heat and high velocity wind pressure etc complete all as specified and as directed Notes: (a) Quoted rate shall be inclusive of following:- (i) Excavation for post holes of min size (400mm x 400mm x600 mm)in any type of soil as required filling in and removal of excess soil. (ii) Duly embedding legs of boards into PCC 1:3:6 type C1 using 20mm graded stone aggregates upto GL. (iii)Writings/alphabates/letters/dashes/arrows etc shall be of different sizes,type etc as per requirement of AF authorities.
EXTERNAL WATER SUPPLY
Material and labour for construction of PCC block masonary valve pit chamber of size 450x450x600mm internal dimensions with 150mm thick PCC foundation 1:4:8 type D-2 using 40mm graded stone aggregate with 150mm wide off sets ground, block masonary (1:3:6) built in CM 1:6, 150mm thick coping in PCC 1:2:4 type B-1 finished even and smooth, rendering 15mm thick in cement mortar 1:4 finished even and smooth internally and renering 15mm thick in cement mortar 1:6 finished fair and even externally including excavation earth work in any type of soil returning and filling , removal of surplus soil to a distance not exceeding 50 metre, 3mm thick MS sheet cover fixed on 50mm x 50mm x6mm thick angle iron rame embedded in PCC coping with locking arrangement and mild steel hold fast mild steel handles and painting to steel surfaces with two coats of black synthetic enamel paint over a coat of red oxide primer and plaster surface with three coats of white wash etc complete all as specified and dirrected
EXTERNAL ELECTRC SUPPLY
Dismantling and taking down of existing High mast of any type and height alongwith fittings and fixture complete including dismantling of foundation, earth work complete and kept aside for schedule fo credit complete all as specified and directed
Dismantling and taking down of existing flood lights of any type and height alongwith fittings and fixture alongwith mounting arrangements complete and kept aside for schedule of credit or reuse at site complete all as directed
Taking out the existing LT/HT cable after disconnecting from over head lines, LT Panels, DBs and other similar equipments or from trenches, pole etc and kept aside for schedule or credit all as required and directed at site. Note: excavation and earth work will be measured and paid seprately.
M & L for local tibba Sand as in cushioning to under ground cable in trenches /existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable complete all as specified and directed . note: Pundowned thickness of 18cm shall be considered for measurement and payment purpose
M&L for Design, supply, erection, commissioning and testing of outdoor type LT Panel, platform mounted, suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos stepped type main copper bus bars of 150 Amps, looping & branch connection system shall be made with suitable rating copper bus bar having sleeves of colour coded .The chamber shall be painted with powder coated paint (Shade : RAL-7032) after 9 tank pre-treatment of surfaces. The LT Panel shall be provided with suitable Neoprene rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The LT Panel shall be made out of 3.15mm thick CRCA mild steel sheet and 3.00mm thick gland plate , front door (02 layers) and rear Door (01 layer) opening facility and 4 side slanting canopy type roof on top and mild steel channel (75 MC) base frame at bottom. All incoming MCCBs shall be marked with location and rating of MCCBs. The Feeder Pillar shall be provided with ventilation facility in the form of louvers for better heat dissipation in and including the followings : CONTROL WIRING : All control wirings shall have to be carried out with 1100 volts rated FR grade PVC insulated multi-flexible type copper wire of cross sectional area 1.50Sqmm and shall be properly bunched, tied and dressed, ferrule marked for proper identification and crimped with suitable size and type of tinned copper lugs and shall be wrapped with PVC spring type tube near the door hinges.
CABLE ALLEY- Cable alley shall be provided in both side of the panel of suitable space for all incoming and outgoing cables. Cable terminals shall be provided for conecting of all incoming and outgoing cables, INCOMING :- MCCB 100 Amps, 4 pole, 415 volts, 25 kA, 50 Hz, Thermal magnetic release - 01 Nos OUTGOING : (a) MCCB 63 Amps, 4 pole, 415 volts, 16 KA, 50 Hz, thermal magnetic release, adjustable to 70% to 100 % - 01 Nos (b) MCCB 40 Amps, 4 pole, 415 volts, 16 KA, 50 Hz, thermal magnetic release, Thermal magnetic release, adjustable 70% to 100% - 04 Nos (c) Digital volt meter 96mm x 96mm suitable to read 0 to 500 volts, accuracy class 1% - 01 Nos (d) Digital Ammeter 96mm x 96mm suitable to read 0 to 100 Amps, accuracy class 1% - 01 Nos (e) Current transformer (CT) of rating 100/5, tape wound, rated burden 5 VA - 03 Nos (f) LED indicator lamps complete with integral circuit and cluster LED, suitable to operate in 230-240 Volts AC supply - 1set of 03 Nos (Red - 01, Yellow- 01, Blue - 01)
(g) Control fuse holder, made of bakellite, 16 Amps rating, stud type, pannel door mounting complete with 01 No 02 Amps HRC fuse of suitable type- 03 Nos (h) Copper bus bar of suitable size and length duly mounted on FRP bus bar insulators and marked with standard colour coded sleeves / tapes for all outgoing MCCBs (j) LED Pilot Lamp of following colours : (i) RED - 01 No, YELLOW - 01 No, BLUE - 01 No. (k) Danger Notice Plate -02 Nos (l) Power contactor four pole with coil voltage 230 volt of capacity 25 Amps 50 cycles. - 01 Nos (m) Time switch microrex analog time switch -01 Nos (n) Pannel box made up of CRCA mild steel 3.15mm thick, duly powder coated with busbar and internal wiring all as per CPRI approved (The panel shall not be less than 1.0 Sqm front area and depth 500mm) ' Note : Panel will be manufactured by CPRI approved firm . The contractor shall submit drawing of the panels to Engr-in-charge before procurement of LT panel for approval alongwith CPRI approval letter. Foundation will prepared as per instructions of manufacturer and rate of fondation shall be deemed to be included in the quoted rates.
M&L for Design, supply, erection, commissioning and testing of outdoor type LT Panel, platform mounted, suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos stepped type main copper bus bars of 250 Amps, looping & branch connection system shall be made with suitable rating copper bus bar having sleeves of colour coded .The chamber shall be painted with powder coated paint (Shade : RAL-7032) after 9 tank pre-treatment of surfaces. The LT Panel shall be provided with suitable Neoprene rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The LT Panel shall be made out of 3.15mm thick CRCA mild steel sheet and 3.00mm thick gland plate , front door (02 layers) and rear Door (01 layer) opening facility and 4 side slanting canopy type roof on top and mild steel channel (75 MC) base frame at bottom. All incoming MCCBs shall be marked with location and rating of MCCBs. The Feeder Pillar shall be provided with ventilation facility in the form of louvers for better heat dissipation in and including the followings :
CONTROL WIRING : All control wirings shall have to be carried out with 1100 volts rated FR grade PVC insulated multi-flexible type copper wire of cross sectional area 1.50Sqmm and shall be properly bunched, tied and dressed, ferrule marked for proper identification and crimped with suitable size and type of tinned copper lugs and shall be wrapped with PVC spring type tube near the door hinges.
CABLE ALLEY- Cable alley shall be provided in both side of the panel of suitable space for all incoming and outgoing cables. Cable terminals shall be provided for conecting of all incoming and outgoing cables, INCOMING :- MCCB 250 Amps, 4 pole, 415 volts, 35 kA, 50 Hz, Thermal magnetic release - 01 Nos OUTGOING : (a) MCCB 160 Amps, 4 pole, 415 volts, 25 KA, 50 Hz, thermal magnetic release, adjustable to 70% to 100 % - 01 Nos (b) MCCB 63 Amps, 4 pole, 415 volts, 16 KA, 50 Hz, thermal magnetic release, Thermal magnetic release, adjustable 70% to 100% - 01 Nos (c) MCCB 40 Amps, 4 pole, 415 volts, 16 KA, 50 Hz, thermal magnetic release, Thermal magnetic release, adjustable 70% to 100% - 04 Nos (d) Digital volt meter 96mm x 96mm suitable to read 0 to 500 volts, accuracy class 1% - 01 Nos (e) Digital Ammeter 96mm x 96mm suitable to read 0 to 250 Amps, accuracy class 1% - 01 Nos (f) Current transformer (CT) of rating 250/5, tape wound, rated burden 5 VA - 03 Nos
(g) LED indicator lamps complete with integral circuit and cluster LED, suitable to operate in 230-240 Volts AC supply - 1set of 03 Nos (Red - 01, Yellow- 01, Blue - 01) (h) Control fuse holder, made of bakellite, 16 Amps rating, stud type, pannel door mounting complete with 01 No 02 Amps HRC fuse of suitable type- 03 Nos (j) Copper bus bar of suitable size and length duly mounted on FRP bus bar insulators and marked with standard colour coded sleeves / tapes for all outgoing MCCBs (k) LED Pilot Lamp of following colours : (i) RED - 01 No, YELLOW - 01 No, BLUE - 01 No. (l) Danger Notice Plate -02 Nos (m) Power contactor four pole with coil voltage 230 volt of capacity 25 Amps 50 cycles. - 01 Nos (n) Time switch microrex analog time switch -01 Nos (o) Pannel box made up of CRCA mild steel 3.15mm thick, duly powder coated with busbar and internal wiring all as per CPRI approved (The panel shall not be less than 1.20 Sqm front area and depth 500mm) ' Note : Panel will be manufactured by CPRI approved firm . The contractor shall submit drawing of the panels to Engr-in-charge before procurement of LT panel for approval alongwith CPRI approval letter. Foundation will prepared as per instructions of manufacturer and rate of fondation shall be deemed to be included in the quoted rates.
Supply, fixing, connecting and testing of Automatic Street light switch using infrared Sensor based Nature Switch for automatic switching of street lights, Nature switch operation should be based on Natural light lux level. Required illumination level for switching on is < 30 lux and for switching off > 10 lux. The sensor should also have part night operation facility for 4 - 12 hours. The sensor alongwith suitable power contactor, incoming-outgoing MCBs should be enclosed in a pole/wall moutaed enclosure made out of Rust proof, electric shock proof, termite proof and FR grade SMC junction box conforming to IP-54, The circuit should be suitable enough to take 8 kw Three phase load with contactor 25 Amps conforming to IEC-60947-4-1/IS-13947-4-1 & incoming and outgoing MCBs of rating 32 Amps conforming to IEC-60898/IS-8828 and circuit wiring of minimum 10sqmm copper conductor wire in and including providing of 50x6mm flat iron clamp, necessary nuts and bolts, complete all as specified and directed . Make of nature switch - Model No Swadeep-02EC8kw3P of Kakatiya Energy System or equivalent make of Bajaj/Healer, Make for Contactor- BCH/L&T/Schneider, Enclouser - Sintex or equivalent
Supply and fixing, erecting, and assembling of 2 feet long pole with CI cable terminal box, base plase and breakable coupling complete all as specified and directed
Boring of holes under pavement by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 80mm dia suitable for 0.4mpa working pressure
M&L for cutting of black top cover of existing road upto 0.6 mtr depth and upto 45cm wide for laying of UG cable and pipe line, refilling and making good after laying UG cable and pipe line with PCC 1:3:6 upto 30 cm from top of the road surface complete all as specified and directed by Engr - in-charge
Sch of credit Rs 2853961.00
Brahma Infra
B D Raizada Projects Pvt Ltd
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
BOQ_696262.xls
BOQ Document • 1.26 MB
130986647.pdf
Tender Document • 0.18 MB
uploaded81216.rar
Tender Document • 2.15 MB
Drg1.rar
Tender Document • 20.37 MB
Drg2.rar
Tender Document • 25.74 MB
130986649.html
Tender Document • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .