Loading…
Loading…
Tender Value
₹43.6 L
EMD Value
₹87,300
Closing Date
24 Aug 2026, 6:00 pmDue today
CWE Ranchi
Headquarters Commander Works Engineers Ranchi Military Engineer Services Dipatoli Mil Station Hotwar, Ranchi-834009
PROVN OF 100 KVA TRANSFORMER ALONGWITH ACCESSORIES AT LONG RANGE AT OTA GAYA UNDER GE GAYA
2026_MES_781301_1
80599/1725/E8
Open Tender
Electrical and Maintenance Works
Item Rate
90 days
GE Gaya
As per tender documents
7 documents required · 7 mandatory
₹500
GE Gaya
₹87,300
Yes
HQ CWE Ranchi
3 Aug 2026
3 Aug 2026
31 Aug 2026
3 Aug 2026
24 Aug 2026
17 Aug 2026
3 Aug 2026 - 10 Aug 2026
10 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M&L for provision of transformer plinth of size 2.5 x 2.5 mtrs and 1.5 mtr above ground level complete with fencing by using ms angle posts, GI pipes, chain link fence and babrbed wire with safety standard IS 3034, IS 875 and PCC foundation, RCC Slab and gravel filling all around all as shown TD-251 Sheet 1/1 complete all as directed. | 1 | Each Job | - | - |
| 2 | Supply , installing, testing and commissioning of outdoor type step down transformer 11000/433 volts (at no load), AC , 3 phase 50 Hz , copper wound type complete with standard fittings, 11 KV 3 phase , LT 433 volts, 3 phase 4 wire with off load tappings on HT side to vary secondary voltage within limit, all as per IS: 1180 (with latest amendments) of capactiy 100 KVA. of level 3 ,core type copper wound,oil immersed, naturally cooled, oil nature,air nature(ONAN) with external cooling tubes/fins delta connected on primary side (HV) and star connected on secondary side(LV) in accordance with vector symbol DYN-11(Vector group)with neutral brought out on secondary side (LV side ) and having tapping upto ±7.5% HV side in step of ±2.5% to be changed by means of hand operated off load tap changer gear. the maximum temparature rise should not exceed 45 degree celsius in oil and 55 degree celsius in HV/LV winding when measured by resistance method after continuous full load run on an ambient temparature of 40 degree celsius. The transformer shall be IS 1180 marked and shall comprise of the following :-
(a) cable box on HT side suitable for 11 KV complete with insulator,copper rods, nut and washers.
(b) One cable box on LT side (secondary side ) consisting of 04 No of porcelain bushing with copper rod , complete with nuts and washers with two numbers cable glands suitable for reception /taking out of XLPE insulated heavy duty armoured cable including glands, joints and jointing material complete. | 1 | Each | - | - |
| 2.01 | (c) Oil conservator with filter type drain valve and oil level gauge
(d) Dehydrating breather with first fills dehydrating agents (silca gel)
(e) Thermometer pocket on tank cover
(f) One number 100 mm dia, dial type thermometer, vapour pressure type having range 0-120 degree celsious wth metal guard having max perimeter reading tempreture indicator with resisting device for transformer
(g) Two earthing terminal on tank cover to facilitate fixing of 32x6 mm GI earth strip for earhting of neutral and body. complete all as directed.
(h) Rating plate and terminal marking plate
(i) Oil level gauge
(j) Oil drain filter valve
(k) Lifting legs
(l) Oil filling holes with cap/plug with connecting plate complete
(m) Air release plug
(n) Four plain solid cost steel detachable rollers
(o) Extra bushing for neutral, outside LT cable box for proving independent earthig for neutral
(p) First filling new and unused transformer oil IS-335/93(forth version) marked (make -HP/power oil or equivalent as approved by GE) filtered and tested dielectric strength at 2.5 mm air gap between testing electrode asper IS 335.
Note: Certification of electric strength shall be submitted by the cotractor after filling the oil. | - | - | - | - |
| 3 | Supplying, transporting and erecting in position steel tubular swaged poles 410-SP-55 type, 11.00 metre long complete with mild steel base plate, CI finial taper, bolts, nuts and washers etc ,painting steel tubular poles exposed surfaces with aluminium paint two coats over one coat of red oxide primer and providing painting of 30 cm wide red and white strips upto 1.5 mtr from bottom of the errected pole, painting embedded portion of poles with one coat of bituminious paint including marking of pole number etccomplete all as directed. | 2 | Each | - | - |
| 4 | M&L for cross arms, bracing supports, clamps back plates angles fabricated from the structural steel section including bolts, nuts, washers, welding, bending, drilling holes for bolts, bent to any required shape of size as indicated or directed, inclusive of one primer coat and two coats of aluminium paint after preparation of surfaces complete all as specified and directed. | 1.35 | Qtl | - | - |
| 5 | S&F in repair Anti-climbing device, spikes type fabricated out of comprising 2.24mm dia galvanised steel 2-strand barbed wire with 2.00mm dia barbs wrapped spirally round poles, to a length of 0.5 to 1.0 metre clamped and properly secured or as ordered with & including two coats of aluminium paint over a coat of red oxide zinc chrome primer, complete all as specified and directed. | 0.3 | Qtl | - | - |
| 6 | Supply, fixing, testing and commissioning air break isolating switch tripple pole mechanically operated with vertical isolation,9 nos. polymer type insulators mounted on steel frame with operating mechanism worked from ground level and including operating rod of 25 mm dia medium grade GI pipe and locking arrangement of capacity 200 Amps 11 KV with drop out fuse set including making all incoming/outgoing connection of HT cable and overhead conductor using new leads and nuts, bolts etc and painting of steel work with 2 coats of aluminium paint over a coat of red oxide primer complete all as specified and directed. Make: Jaipuria/Pactil/Alstom | 2 | Each | - | - |
| 7 | Supply and fix Lightening arrestor Non Linear metal oxide type conform to IS 3070 (part I) complete with all fittings transmission classes discharge Capacity 65 KA suitable for 11 KV out door type complete all as specified and directed including taking down the existing LA. | 1 | Set of three | - | - |
| 8 | M&L for cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and directed. | 3 | Each | - | - |
| 9 | M&L for cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and directed. | 1 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.32 MB
BOQ_875235.xls
BOQ • 0.48 MB
1725Tender.pdf
Tender Documents • 0.60 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].