Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹14.5 LAccepted-AOC 02 JAMEEWAR COMPLEX RING ROAD HANUMAN NAGAR GONDIA MAHARASHTRA 441614 | GONDIA | MAHARASHTRA | 441614 | 1 | Accepted-AOC Being L-1 | |
| 2 | 2₹15.5 L+₹78,335 (5.31%)Rejected-Finance | 2 | Rejected-Finance Being other than L-1 | |
| 3 | 3₹15.8 L+₹1.1 L (7.16%)Rejected-Finance | 3 | Rejected-Finance Being other than L-1 | |
| 4 | 4₹16.0 L+₹1.3 L (8.70%)Rejected-Finance 41B 1H JAYANTIPUR PREETAM NAGAR ALLAHABAD | 4 | Rejected-Finance Being other than L-1 | |
| 5 | 5₹16.2 L+₹1.5 L (10.1%)Rejected-Finance VILLAGE MATPUR POST OFFICE MANAURI ALLAHABAD 212208 | PRAYAGRAJ | UTTAR PRADESH | 212208 | 5 | Rejected-Finance Being other than L-1 |
Tender Value
₹22 L
EMD Value
₹44,000
Closing Date
29 Nov 2022, 6:00 pmClosed
Col Sharath Ravindran CWE
HQ CWE (AF) Chakeri Pin-208008
RENOVATION OF QA SECTION BUILDING WITH REPLASTERING, FALSE ROOFING, DISTEMPERING AND REWIRING AT 24 ED AT STN MANAURI
2022_MES_561007_1
CA No. CWE(AF)/CHK/MNR/T-30 OF 2022-23
Open Tender
Civil Works
Item Rate
180 days
AGE (I) AF Manauri
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
AGE (I) AF Manauri
₹44,000
26 Dec 2022
2 Nov 2022
1 Dec 2022
2 Nov 2022
29 Nov 2022
17 Nov 2022
Amount
B/R PORTION Taking down existing water proofing treatment and cleaning roof surface by washing and rubbing etc and removing retrieved material to a distance n.exc 500m where directed and M & L for roof treatment with APP polymeric water proofing membrane all as given below :- (a) M & L for plastering 10mm thick in CM 1:3 using 100% coarse sand on roof surface including water proofing compound as per manufacturers instruction and as directed by Engr-in-Charge. (b) Applying a coat of bituminous primer confirming to IS:3384-1986 @ 0.40 Ltr/Sqm and allow to dry. (c) M & L for laying 3mm thick APP modified polymeric water proofing membrane having weight 3.2 - 3.5 Kg/Sqm on prepared surface as per manufacturers instructions and over laps 10 cm and 15 cm longitudinal and traverse directions respectively and sealed by flame, sealing all overlaps complete including treatment at all junctions and corners.The membrane shall be torched into groove on vertical plane and grove sealed with cement mortar 1:3. (d) Applying two coats aluminium paint over membrane @ 1.20 Kg/Sqm and all as per specification and directed by Engr-in-Charge.
Dismantling stone slabs and tiles of any description or thickness in floors, aprons etc. laid, bedded and pointed in any mortar complete all as specified and directed by Engineer in charge.
Dismantling wall tiles including cement mortar bedding, removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer in charge.
M & L for 25mm thick PCC 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) as sub base for floors to receive tiles complete all as specified and directed by Engineer in charge.
M & L for vitrified ceramic tiles 10 mm thick (square/rectangular) polished, area of each tiles not exc 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with existing tiles including 15 mm thick screed bed or bedding layer in CM 1:6 complete all as specified and directed by Engineer in charge.
M & L for non skid ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.11 sqm but not exc 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with existing tiles including 15 mm thick screed bed or bedding layer 15 mm thick in CM 1:6 complete all as specified and directed by Engineer in charge.
M & L for glazed ceramic tiles in vertical surface 450 x 300 x 7 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match with existing tiles including 10 mm thick rendering in CM 1:4 complete all as specified and directed by Engineer in charge.
M & L for 18-20mm thick granite work of any type in window cills, cooking platforms and like set in cement plaster 1:4 including pointing with white cement 1:2 using marble dust with admixture of pigment to match with shade of granite including 15 mm thick screed bed or bedding layer in CM 1:6 complete all as specified and directed by Engineer in charge.
M & L for rounding to edges of stone slabs, cooking platform and similar situations complete
Taking down chowkats or frames (without taking off shutters from frames) not exc 1.5 sqm each and remove from site complete all as specified and directed by Engineer in charge.
Taking down chowkats or frames (without taking off shutters from frames) exc 1.5 sqm but n.exc 4 Sqm each and remove from site complete all as specified and directed by Engineer in charge.
S & F powder coated anodised aluminium windows and ventilators with frames, shutters and grill frames provided with two or more tracks including jointing cleat for fixing and including all fittings like handles, locks, latches etc complete all as specified in Drg No CE (AF)/NGP/TD-109/2012, Sheet 1 to 4/4 complete all as specified and directed by Engineer in charge.
S & F powder coated anodised aluminium doors frames and shutters fixed or side hung including jointing cleat for fixing including all fittings like handles, locks, hinges, stoppers, latches etc complete all as specified in Drg No CE (AF)/NGP/03/TD/32, Sheet 1 to 2/2 complete all as specified and directed by Engineer in charge.
S & F 5.5 mm thick sheet glass, ordinary quality fixed to aluminium doors exc 0.5 sqm in each pane complete all as specified and directed by Engineer in charge.
S & F aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed to aluminium windows & ventilators with aluminium wire staples complete all as specified and directed by Engineer in charge.
S & F solar control film 25 micron reflective type sticked to glass planes as per manufacturers instructions complete all as specified and directed by Engineer in charge.
S & F anodised powder coated aluminium grills of approved design and pattern, with approved standard section fixed to the window frame all as specified by Engr-in-Charge
S & F solid PVC frame (single rebated) of size 60mm x 30mm made out of solid PVC foam with homogenous fine cellular structure having smooth outer intefral skin with suitable metal stiffner and fixed with 100 x 8 sheet metal CSK screws complete all as specified and directed by Engr-in-charge
S & F factory made solid PVC profiled panel door shutter 28mm thick with integral skin as frame & 3mm thick high pressure compact laminate on both side of approved colour as infill, with 'C' type GI or 40 x 20 x 19 of MS pipe as stiffner & S & F in frame as specified & directed by Engr-in-Charge
S&F butt hinges medium weight cold rolled mild steel 125mm size, ISI marked all as specified.
S&F extruded aluminium alloy handles, anodized 150 mm size complete all as specified and directed.
S&F Aluminum Barrel tower bolt 300mm complete all as specified and directed
S&F aluminium anodised 300mm long sliding door bolt with hasp and staple (bolt type) and fixing clip and bolt extrude section or cast alloy type all as specified and directed.
M & L floor door stopper of aluminium alloy body and tongue, anodized with rubber washer at bottom fixed with screw to body and fixed to door shutter, over all length of cover plate shall be 140 mm complete all as specified and directed.
S & F grid false ceiling in GI system powder coated prelude main runner section 38 x 24 x 0.40mm, cross 'T' 28 x 24 x 0.40mm, wall angle 24 x 24 x 0.40mm and including providing and fixing designer not less than 4mm thick cement building board/E-Board with designer finishing of size 595 x 595mm fixed in ceiling frame work with all necessary hanging washers, expansion holding fasteners etc for securing framework to ceiling wherever required complete all as specified and directed.
Taking down cement plaster, any description on brick walls or on concrete surfaces including raking out joints, hacking for key, scrubbing down with water, etc., and removing same from the site(s), complete all as specified and as directed
M & L for rendering 15 mm thickin CM 1:6 on fair face of brick walls or concrete surface finished even and smooth without using extra cement complete all as specified and directed.
M & L for preparation of old surface of wall, complete removal of existing treatment and washing, rubbing down and stopping of distempered and painted surfaces and applying 2mm thick wall care putty on walls, complete all as specified and directed by Engr-in-charge
M & L for preparation of walls and applying two coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (company depot tinted) with silicon additives at 1.43 litre/10 Sqm over and including priming coat of exterior primer applied at 0.90 litre/10 sqm all as directed
M & L for preparation of old painted surfaces and applying one coat of oil bound distemper on wall complete all as specified & directed by Engr-in-Charge
M & L for preparation of new surface and applying two coats of oil bound distemper over a coat of primer on wall complete all as specified & directed by Engr-in-Charge
M & L for preparation of old plastered surface of ceiling including cornices and apply one coat of white wash complete all as specified and directed by Engineer-in-Charge.
S & F vitreous china wash down water closed pan (pedestal pattern), seat cover, fixing bolts and flush pipes complete all as specified and directed by Engineer-in-Charge.
S&F 10 ltr capacity PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets and PVC flush pipe complete all as specified and as directed.
S & F in Vitreous China wash basin, white, flat back, of size 550x450mm including brackets(flat back or angle back type) any size, including cutting for and pinning in ends of brackets or erecting stand including CP waste coupling and 32mm dia waste pipe compete all as specified and directed. Make-Cera/Hindware/Parryware or equivalent make as per list of make Appx 'B' duly approved by GE.
S&F vitreous China Urinal, Half stall type, white (excluding flushing cistern, flush pipe and waste pipe) complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with screws, pointing around urinal back in cement; including flush pipe, grating and union for discharge pipe complete all as specified and directed.Make-Cera/Hindware/Parryware or equivalent make as per list of make Appx 'B' duly approved by GE.
S & F PVC (SWR) 75mm floor trap, plain with grating including jointing with solvent cement compete all as specified and directed.
S & F 110mm PVC (SWR) WC connector with lip ring compete all as specified and directed.
S & F PVC (SWR) 110 mm bends any radius compete all as specified and directed.
S & F PVC (SWR) 75 mm bends any radius compete all as specified and directed.
S & F 110mm PVC (SWR) pipe single socketed, in any length with rubber ring joints, laid in trenches or in floors compete all as specified and directed.
S & F 75mm PVC (SWR) pipe single socketed, in any length with rubber ring joints, laid in trenches or in floors compete all as specified and directed.
S & F PVC connections 15mm size with PTMT nuts of length 600mm compete all as specified and directed.
S&F in repairs 15mm bore Bib taps, chromium plated with capstan head, screwed down, crewed for iron pipe or for brass ferrule and fixed all as specified and directed. Make-Prayag/Jaquar/Cera/Marc or equivalent make as per list of make Appx 'B' duly approved by GE.
S&F in repair 15mm bore Pillar taps, cast copper alloy, with capstan head, fancy type chromium plated screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed all as specified and directed.Make: Prayag/ Jaquar/ Cera/ Marc or equivalent make as per list of make Appx 'B' duly approved by GE.
S&F in repair 15 mm bore stop cock/angle valve cast copper alloy , chromium plated fancy type screwed down high pressure , screwed both ends for iron pipe or for union complete all as specified and as directed. Make: Prayag/ Jaquar/ Cera/ Marc or equivalent make as per list of make Appx 'B' duly approved by GE
S&F in repair steel water tubing 15mm dia (Bore), galvanised, ‘medium grade’ with all fittings, fixed on walls, ceiling or laid in floors or any other situation with fittings and connections, etc., complete all as specified & directed.
S&F in repair steel water tubing 20 mm dia (Bore), galvanised, ‘medium grade’ with all fittings, fixed on walls, ceiling or laid in floors or any other situation with fittings and connections, etc., complete all as specified & directed.
S&F in repair 500 ltr rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position including 15 mm bore PVC float/ball valve with aluminium rod including nipples of suitable dia and size complete all as specified & directed.
S&F of brass CP tubular towel rail 20 mm dia 60cm long between flange with brackets etc complete all as specified & directed.
S & F hand shower (health faucet) with 1 Mtr flexible tube, wall hook, bracket etc complete set of superior quality complete all as specified & directed. Make Prayag/ Jaguar/Marc/Plumber or equivalent make as per list of make Appx 'B' duly approved by GE.
S&F in repairs looking mirror fancy type decorative pattern 5 to 6 mm thick fixed on wall with stainless steel studs complete all as specified and directed.
S & F kitchen sink with drainage board size 915mm x 460mm, bowl size 410 x 330 x 160mm made of stainless steel sheet 1.00mm thick plugs, washers and waste pipe and coupling etc including bedding in cement mortar or dwarf wall or cantilever brackets and connection compete all as specified and directed.
S & F toilet paper holder CP box type compete all as specified and directed.
S & F PVC grating doom 125mm dia with or without hole compete all as specified and directed.
S & F soap dish, any type, fixed to plugs with chromiun plated brass screws compete all as specified and directed.
S & F rolled mild steel in stairs (framed) including stringers, treades, landing, balusters, hand rails etc including cleats, brackets, etc. complete or equivalent make as per list of make Appx 'B' duly approved by GE)
M & L 75 mm thick cement concrete type C- 1, 1:3:6 ( using 20 mm stone graded aggregate) as in plinth protection finishing surface even and smooth without using extra cement complete all as specified and as directed.
Excavation in trenches in soft/loose soil not exceeding 1.50 mtr wide and not exceeding 1.50 mtr in depth for foundation,laying of cables and getting out including trimming of sides complete all as specified and directed by Engineer-in-Charge.
M & L for returning, filling in, including spreading, levelling, watering and well ramming in layers n exc 25 cm in soft/loose soil complete all as specified and as directed.
Removing excavated material n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and as directed.
M & L for PCC D-2 1:4:8 (40 mm graded stone aggregate) in foundation, filling and mass complete all as specified and as directed.
M&L for brick work with sub class 'B' bricks, straight or curved on plan exc. 6 mtr mean radius built in CM(1:6) complete all as specified and as directed.
M & L for rendering 15 mm thick in cement mortar 1:4 on fair faces of brick work finished even and smooth without using extra cement complete all as specified and as directed.
M & L for providing broken stones hardcore of gauge n.exc 63mm deposited, spread and levelled n.exc 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
M & L for 100 mm PCC 1:4:8 type C2 (using 40mm graded stone aggregate) as in mass concrete as subbase for flooring complete all as specified and as directed.
M & L for exterior grade heavy duty full body outer designer parking tiles 400 x 400 x 10 mm, in floors etc. of colour and design as approved by Engr-in-Charge, set and jointed in neat cement slurry and pointed in white or coloured cement to match with existing one including 15 mm thick screed bed in CM 1:6 complete all as specified and as directed.Make:kajaria/Orient Bell/H&R Johnson or equivalent make as per list of make Appx 'B' duly approved by GE)
S&F rolled section as in main and cross beam, hip and jack rafters, purlins where connected to common rafter and running rails etc complete conforming to Fe-410-0 or Fe 310-0 complete all as specified and directed.
S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified including making grooves of minimum 50mm into brick walling and inserting the sheets into these grooves complete all as specified and directed.
S&F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof ridges and valley gutters,fixed with self tapping screws as specified and directed.
M & L for preparation of new plastered surface of wall including cornices and apply two coat of cement based paint over a coat of primer etc complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new steel surfaces of any description over 10cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for applying two coats of synthetic enamel ordinary tint paint on previously primered new steel or iron surfaces of any description, over 10cm in width or girth not otherwise described complete all as specified.
E/M PORTION: Taking down aluminium point wiring for light, fan, bell socket, power socket etc complete including fittings and fixtures removing from site and making good disturbed surfaces of walls, floors, etc complete all as directed by Engineer-in-Charge
M & L for concealed point wiring on wall and surface on ceiling/roof with necessary fixing arrangements with PVC-FRLSH insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid ivory PVC conduit medium grade ISI marked not less than 19 mm dia with all conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.6 mm with earth dolly and modular white cover plate with frame for fixing of switches / sockets, fan regulators, wall mounting fittings, door bell & bulkhead etc with MS screw and cup washers including PVC-FRLSH insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar (1:3) and for matching / finishing of new surfaces either by means of plaster of paris/ Putty or distemper / colour wash with same existing colour surfaces complete all as specified and directed.
(a) One light/fan point controlled by one, one way switch
(b) One socket outlet 3 Pin, 6 Amp on independent board
(c) One socket outlet 3 Pin, 6 Amp on same board.
All as per item No 75 here-in-above but for power point wiring with 2.5 Sqmm PVC-FRLSH insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 2.5 Sqmm PVC-FRLSH insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead.
S&F Modular switch 6 Amp 250 V AC one way one module Make : Legrand /Schneider /Havells or equivalent make as per list of make Appx 'B' duly approved by GE.
S&F Modular switch 20 Amp 250 V AC one way with indicator one module Make : Legrand /Schneider /Havells or equivalent make as per list of make Appx 'B' duly approved by GE.
S&F Modular Socket, 6A - 2/3 pin combined 2 module Make : Make : Legrand /Schneider /Havells or equivalent make as per list of make Appx 'B' duly approved by GE.
S&F Modular Socket 6A/16A - 2/3 pin combined 2 module Make : Legrand /Schneider /Havells or equivalent make as per list of make Appx 'B' duly approved by GE.
S&F modular Fan regulator step type, 120W - 2 module Make : Legrand /Schneider /Havells or equivalent make as per list of make Appx 'B' duly approved by GE.
Supply and fix Metal flush mounting box of 1/2 Module complete all as specified and as directed. Make : Legrand /Schneider /Havells or equivalent make as per list of make Appx 'B' duly approved by GE.
Supply and fix Metal flush mounting box of 3 Module complete all as specified and as directed.Make : Legrand /Schneider /Havells or equivalent make as per list of make Appx 'B' duly approved by GE.
Supply and fix Metal flush mounting box of 4 Module complete all as specified and as directed. Make : Legrand /Schneider /Havells or equivalent make as per list of make Appx 'B' duly approved by GE.
Supply and fix Metal flush mounting box of 6 Module complete all as specified and as directed. Make : Legrand /Schneider /Havells or equivalent make as per list of make Appx 'B' duly approved by GE.
Supply and fix Metal flush mounting box of 8 Module complete all as specified and as directed. Make : Legrand /Schneider /Havells or equivalent make as per list of make Appx 'B' duly approved by GE.
Supply and fix Metal flush mounting box of 12 Module complete all as specified and as directed. Make : Legrand /Schneider /Havells or equivalent make as per list of make Appx 'B' duly approved by GE.
S & F white colour modular blanking plate, one module i complete all as specified and directed. Make : Legrand /Schneider /Havells or equivalent make as per list of make Appx 'B' duly approved by GE.
Supply and fix white colour plates with frame for modular switch and socket of 02 module complete all as specified and as directed.Make : Legrand /Schneider /Havells or equivalent make as per list of make Appx 'B' duly approved by GE.
Supply and fix white colour plates with frame for modular switch and socket of 03 module complete all as specified and as directed.Make : Legrand /Schneider /Havells or equivalent make as per list of make Appx 'B' duly approved by GE.
Supply and fix white colour plates with frame for modular switch and socket of 04 module complete all as specified and as directed .Make : Legrand /Schneider /Havells or equivalent make as per list of make Appx 'B' duly approved by GE.
Supply and fix white colour plates with frame for modular switch and socket of 06 module complete all as specified and as directed.Make : Legrand /Schneider /Havells or equivalent make as per list of make Appx 'B' duly approved by GE.
Supply and fix white colour plates with frame for modular switch and socket of 08 module complete all as specified and as directed.Make : Legrand /Schneider /Havells or equivalent make as per list of make Appx 'B' duly approved by GE.
Supply and fix white colour plates with frame for modular switch and socket of 2 x 6 module complete all as specified and as directed.Make : Legrand /Schneider /Havells or equivalent make as per list of make Appx 'B' duly approved by GE.
M&L for ceiling rose, surface Bakelite 65 x 17.50 mm of three terminals PVC/Polycarbonate,isolated body (ISI Marked) complete all as specified and as directed.
M&L for concealed sub main wiring with two runs of single core 6 sqmm (nominal area) PVC insulated and unsheathed multi stranded copper conductor cable LT 1100 grade FRLSH cable drawn and PVC rigid conduit 20 mm dia with all necessary fittings and accessories and run of PVC insulated and unsheathed single core cable with copper conductor of size 6 sqmm as earth wire (green in colour ) run through PVC rigid conduit and connected to common earth dolly , including taking out the old sub main wiring complete all as specified and directed. Note. Two run of cable, one run of earth continuity wire and one run of PVC conduit and shall be measured as one run complete all as specified .
Supply and fixing LED Tube light fitting 20 watt 4 feet pre coated CRCA body heavy duty Industrial box type batten suitable for Retrofit LED Tube 20 watt including LED tube rod 20 watt self ballasted retrofit lamps with thermoplastic body 270 degree wide distribution CCT 6500 K Cat Part No of Crompton Cat Part No for LED Tube Rod LTT8-20 and Batten Cat Part No IGP161LT8-16 or Havells Cat Part No for LED Tube Rod 20 watt LHLDDBXEUL7Z022 and Batten Cat part No LHFYBWP1TB1W020 or equivalent make as per list of make Appx 'B' duly approved by GE including fitting fixed on wall/ceiling and connecting up complete with 3 core flexible cable white of size 23/0.0076 including taking down old unsv tube light fitting and making necessary connection complete all as specified and directed by Engr-in-Charge.
S & F LED tube light fitting 10 watt, self ballasted LED batten, extruded thermoplastic body with PC diffuser in square shape, high translucent serrated milky white diifuser beam angle 120 degree wide distribution 100 Lumen/watt including fitting fixed on wall and connecting up complete with 3 core flexible cable white of size 23/0.0076 including taking down old unsv tube light fitting and making necessary connection complete all as specified and directed by Engr-in-Charge. Make: Havells/ Bajaj/ Philips or equivalent make as per list of make Appx 'B' duly approved by GE.
Supply and fix in repair factory made sheet metal enclosure double door vertical type 4 way IP-43 wih 160 Amp rated copper bus bar, including incoming MCCB 63 Amp TPN 415 Volts 16 KA and earth wire and neutral link, 240 volts complete all as specified and directed Note : Cost of MCCB shall deemed to be included in the item. Make: Legrand/Siemens/L&T/ schneider or equivalent make as per list of make Appx 'B' duly approved by GE.
Supply & fix in repair Prewired Distribution Board factory made sheet metal enclosure double door distribution board class IP-43 IK 09 with 200 Amp rated copper bus bar 240 Volts 8 way (2 + 6 way) single pole and neutral link complete all as directed by Engineer-in-Charge. Make: Legrand/Siemens/L&T/ schneider or equivalent make as per list of make Appx 'B' duly approved by GE.
Supply and fix MCB single pole and neutral (SPN) 25 to 32 Amp 240 volts 10 KA 'C' series with all incoming/outgoing connections with proper size lugs including taking down old unserviceable one complete all as specified and directed.
S&F MCB single pole (SP) 6 to 32 Amp 240 Volts 10 KA 'B' series with all incoming/outgoing connection with proper size lugs including taking down old unserviceable complete all as specified and directed.
S&F MCB single pole (SP) 40 to 63 Amp 240 Volts 10 KA 'B' series with all incoming/outgoing connection with proper size lugs including taking down old unserviceable complete all as specified and directed.
Material and labour for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 mtr below ground level) connected to galvanized iron earth lead wire 4 mm dia (main earthing lead) by means of galvanized bolts, nuts and washers all as shown in electrical plate No 5 of MES shedule Part I (1991) with connected to earth test point & to main switch board with and including adequate quality of charcoal dust and common salt around earth plate and 15 mm dia GI pipe light grade for watering pipe with funnel and wire mesh including necesary eart work and PCC (1:3:6) type C-1 for earth pit and 40 m thick pre-cast. RCC cover in 1:2:4 type B1 with 3 Nos 8 mm dia TMT bars both ways complete including taking down old unsv earthing all as specified and directed by Engr-in-Charge.
Taking down old unserviceable bulk head and Supply and fixing LED decorative building security light fitting 30 watt with PDC aluminium body and clear polycarbonate cover wide beam distribution along with 1.5 mtr GI pipe with two nos clamp, suitable size of nut bolts including fitting fixed on wall and connecting up complete with 3 core flexible cable white of size 23/0.0076 complete all as specified and directed by Engr-in-Charge.Make Crompton cat Part No LSTS-30-CDL/NL-M or equivalent in Havells/Bajaj/Philips or equivalent make as per list of make Appx 'B' duly approved by GE.
M&L for concealed sub main wiring with two runs of single core 10 sqmm (nominal area) PVC insulated and unsheathed multi stranded copper conductor cable LT 1100 grade FRLSH cable drawn and PVC rigid conduit 20 mm dia with all necessary fittings and accessories and run of PVC insulated and unsheathed single core cable with copper conductor of size 10 sqmm 1100 grade FRLSH as earth wire (green in colour ) run through PVC rigid conduit and connected to common earth dolly , including taking out the old sub main wiring complete all as specified and directed. Note. Two run of cable, one run of earth continuity wire and one run of PVC conduit shall be measured as one run complete all as specified .
S&F recess mounted LED fitting 36/40 watt LED luminiare size 2' x 2' Stellux -H series premium commercial luminaire in 4000K with CRCA housing in white powder finish, high translucent PMMA diffuser provides soft glare free light suitable for surface/recess mounted openable clean room luminiare with IP 65 all accessories, pre-wired connecting up complete with 3 core flexible cable white of size 23/0.0076 all as specified and directed by Engineer-in-Charge. Cat Part No LCTRH-36-WW of Make- Crompton or equivalent in Philips/Bajaj/Havells or equivalent make as per list of make Appx 'B' duly approved by GE.
Taking down old unsv fitting and supply and fixing recess mounted LED downlight size 1' x 1' square shape capacity 18 watt with PDC aluminium body and high transmittance diffuser suitable for surface/recess mounted openable cleanroom luminiare with IP 65 complete with all accessories and connecting up complete with 3 core flexible cable white of size 23/0.0076 all as specified and directed by Engineer-in-Charge. Cat part no LCTLSNE-18-FO-CDL of Make : Crompton or equivalent in Bajaj/Havells/Philips or equivalent make as per list of make Appx 'B' duly approved by GE.
Taking down old unsv AC box and Supply & fix single pole and neutral enclosure (MODULAR AC BOX) 4 module in sheet steel with a two pin and earth plug and socket with one single pole MCB 25 Amp 10 KA complete all as directed all as directed by Engineer-in-Charge. Make: Indo Asian/ Schneider/Havells Siemens/Legrand or equivalent make as per list of make Appx 'B' duly approved by GE)
Taking down old unsv ceiling fan/Exhaust fan, sealing cable end, dismantling blades and removing fan and blades and deposit to MES store yard.
Supply and fixing ceiling fans complete with blades, down rods, and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) main connector block etc complete with all accessories including connecting the same to ceiling rose with using flexible copper conductor 23/0.0076 complete all as specified and as directed. Make : Usha/Crompton/Havells or equivalent make as per list of make Appx 'B' duly approved by GE.
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers main connector block etc complete with all accessories including connecting the same to ceiling rose with using flexible copper conductor 23/0.0076 complete all as specified and as directed. Make: Usha/Crompton /Havells or equivalent make as per list of make Appx 'B' duly approved by GE.
Supply, Installation, Testing and Commissioning of Inverter type split Air conditioner units indoor and outdoor complete with cordless remote control unit, with cooling function,3M micro protection filter/Anti bacterial filter high air flow with low noise (Dual protection filter) Auto Air swing, Star rating 5 Star ISEER >5.00, LCD Panel Display,Rotary type compressor of capacity 1.50 Ton Power Supply 220-240 Volts, Single Phase, 50 Hz complete all as directed by Engr-in-Charge. Make : Hitachi/Daikin/O-Genral. Note: Manufacturer test certificate & purchase voucher shall be submitted by contractor while clearing RAR/ payment.
Supply and fixing wall mounted voltage stabilizer of cap 5 KVA, input working range 90 V to 300 V, output working range 200 V to 240 V +- 5%, metal cabinet material, multifunctional digital display, Automatic low & high cut off, initial time delay, Auto start including wall mounting accessories complete all as directed by Engr-in-Charge. Make - V-Guard/AE/ GODREJ/Blue Line/Power Tech or equivalent make as per list of make Appx 'B' duly approved by GE.
Supply and fixing wall mounted fan sweep cap 400 mm, swing type, 240 volts complete with all accessories including connecting the same to 5 Amp socket complete all as specified and as directed. Make - Crompton/Havells/Usha or equivalent make as per list of make Appx 'B' duly approved by GE.
Taking down old unsv garden light and supply and fixing LED Bollard 10 watt in inverted pyramid tripod type LED Bollard with soft 360 light, IP 65 protection, resistant to corrosion with better optic for uniform distribution complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable complete all as specified and as directed. Cat part No LBLS1-10CDL of make - Crompton Greaves or equivalent make as per list of make Appx 'B' duly approved by GE.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6.0 sq mm 2 core complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core complete all as specified and as directed.
Material and labour for sand cushioning with a layer of sand 8cm thick before laying of cable and 15 cm thick after laying of cable in trenches complete all as specified. Note : Only punned thickness 18 cm shall be measured for payment purpose
Material and labour for brick protection using old size sub class ‘B’ new bricks, laid flat dry but jointed, laid length wise perpendicular to the axis of cable all as specified and directed.
Cutting /boring to plinth protection/ hard standing / road etc in suitable depth to across the GI pipe size upto 80 MM dia of bore for drawn through XLPE underground cable for giving mechanical protection to cable complete all as directed. Note ; Quoted rate shall be included the cost of required material for repairing to disturbed surface all as per existed.
Supply and fixing galvainsed steel water tubing light grade 40 mm dia of bore with fix with pole/ surface of wall / laid in trench etc as site using 02 Nos clamp made out by GI strip in size 25x4 mm with nut bolt and washer etc all as directed. Make : Jindal / Tata / Swastik
Material and labour for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 mtr below ground level) connected to galvanized iron strip 32 × 6 mm thick as earthing lead (main earthing lead) by means of galvanized bolts, nuts and washers all as shown in electrical plate No 5 of MES shedule Part I (1991) with connected to earth test point & to main switch board with and including adequate quality of charcoal dust and common salt around earth plate and 15 mm dia GI pipe light grade for watering pipe with funnel and wire mesh including necesary eart work and PCC (1:3:6) type C-1 for earth pit and 40 m thick pre-cast. RCC cover in 1:2:4 type B1 with 3 Nos 8 mm dia TMT bars both ways complete including taking down old unsv earthing all as specified and directed by Engr-in-Charge.
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32 x 6 mm thick galvanised iron strip
Supply and fix single pointed air termination aluminium rod, 12 mm dia 300 mm long alongwith purpose made base plate welded at bottom of termination, of size 10 cm long fabricated out of 25 x 3 mm thick aluminium strip making 9 mm dia for fixing in faster (wooden block) complete all as specified.
Supply and fix aluminium strip 25 mm x 3.15 mm thick complete with saddles and fixing screws etc for roof conductor and down conductor above ground for fitting the strip.
Supply and fix PVC block locally available of size 25 x 10 x 5 mm thick for mounting on top of PCC block and for errection of air termination alongwith bolts and nuts complete all as specified.
M&L Earth test check point by using MS box fabricated out of 1.2 mm thick MS Sheet 15 cm long 10 cm wide and 7 cm deep alongwith 02 Nos isolators (porcelain bridges ) and 10 cm long bronzes/aluminium strip connector for isolation of earth circuit and providing necessary nuts and bolts complete all as specified.
S&F PCC Block size 25cm x 25cm x 30 cm height in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate providing 02 Nos MS fastener at the top of the block by using 8/9 mm dia 20 cm long bolts with T junction of 10 cm & embeded in the PCC block, keep 7 cm portion of the bolt above the upper surface of PCC block alongwith 2 Nos washers and nuts etc complete all as specified.
Minakshi Construction
shubham construction
Bharat Trading Company
m/s neeraj kumar shukla
M/S Garg Sons
GITANSH CONSTRUCTION CO.
HIMANSHU TRADERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .