Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.2 CrAdmitted-Finance | ₹2.2 Cr | L1 | Admitted-Finance |
| 2 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| Sl No | Description | Qty | Unit | GODARA TRADERS L1 |
|---|---|---|---|---|
| 1.00 | Cutting & clearance of jungle, bushes, shrubs Ankra/Ipomoea, Juliflora typna etc. on canal and bunds in dry/moist/slushy conditions including disposal as per instructions of the Engineer-in-charge. Cost of wood has been deducted from rates and thus will be property of contractor after cutting. thick | 20,000 | Per Sq.m | 2.55 ₹51,000 |
| 2.00 | Cutting & clearance of jungle, bushes, shrubs Ankra/Ipomoea, Juliflora typna etc. on canal and bunds in dry/moist/slushy conditions including disposal as per instructions of the Engineer-in-charge. Cost of wood has been deducted from rates and thus will be property of contractor after cutting. ordinary | 10,000 | Per Sq.m | 1.42 ₹14,200 |
| 3.00 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 meter in width as well as 10 Sqm. on plan including disposal of excavated earth upto 50 Mtr. and lift upto 1.5 Mtr. disposed soil to be levelled and neatly dressed: All kinds of soil. | 15,000 | Sq.m | 35.38 ₹5.3 L |
| 4.00 | Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish lead upto 50 Mtr. and lift upto 1.5 Mtr. : All kinds of soil. | 25,000 | Per Sq.m | 9.11 ₹2.3 L |
| 5.00 | Ploughing the existing ground to a depth of 15 cm to 25 cm and watering the same: All kinds of soil. | 15,000 | Per Sq.m | 9.11 ₹1.4 L |
| 6.00 | Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches removing the roots and stacking of serviceable material and disposal of unserviceable material :Beyond 30 cm girth upto including 60 cm girth. | 34 | Each | 141.71 ₹4,818.14 |
| 7.00 | Supply & Planting of shady plants (Neem, Peepal, Goolar, Jamun, Imili or other specified) along road side including the following activities : 1.Prepartion of soil including cleaning & revoving of unwanted shrubs removal of stones & garbage 2.Supply of plant at site of two years of age & height more than 1.50 Mtr.3.Supply of dry manure (Farm yard manure organic).4.Supply of insecticides .5.Digging of pits size 60×60×60 cms including remoal of tones, Manuring application of insecticides & watering at least 15 liter per plant after planting.6.Half brick Circular tree guard in second class bricks, internal dia 1.25 meter and height 1.20 meter above ground and 0.20 meter below ground bottom two courses laid dry and top three courses in cement mortar 1:6 (1 Cement : 6 Sand) and the intermediate course being in dry honey comb masonry, as per design complete.7.Watering to plants.8.Maintenance of plants by the contractor including pits, preparation of Thavala Hoeing weeding etc. & application of insecticides etc. & security. If the plant by die during maintenance contractor has to replace same height plant at his own cost..(without tree guard) | 1,200 | Per Plant | 1,200.01 ₹14.4 L |
| 8.00 | Supply & Planting of ornamantal plants (Kachnar, Amaltas, Gulmohar, Arjun, Kala Siris, Jacranda etc. or other specified)1.Prepartion of soil including cleaning & revoving of unwanted shrubs removal of stones & garbage 2.Supply of plant at site of two years of age & height more than 1.50 Mtr.3.Supply of dry manure (Farm yard manure organic).4.Supply of insecticides .5.Digging of pits size 60×60×60 cms including remoal of tones, Manuring application of insecticides & watering at least 15 liter per plant after planting.6.Half brick Circular tree guard in second class bricks, internal dia 1.25 meter and height 1.20 meter above ground and 0.20 meter below ground bottom two courses laid dry and top three courses in cement mortar 1:6 (1 Cement : 6 Sand) and the intermediate course being in dry honey comb masonry, as per design complete.7.Watering to plants.8.Maintenance of plants by the contractor including pits, preparation of Thavala Hoeing weeding etc. & application of insecticides etc. & security. If the plant by die during maintenance contractor has to replace same height plant at his own cost.(without tree guard) | 1,100 | Per Plant | 1,515.77 ₹16.7 L |
| 9.00 | Planting & Maintenance of shrubs.Planting of shrubs in central verge 1.Preparation of soil including cleaning & removing of unwanted shrubs removal of stones & garbage. 2.Supply of plant at site like Bouganvillia & Kankar.3.Supply of dry manure (Farm yard manure organic).4.Supply of Insecticides.5.Digging of pits size 60×60×60 cms including removal of stones, Manuring application of insecticides & watering at least 15 liter per plant after planting.6.Watering to plants. 7.Maintenance of plants by the contractor including pits, preparation of Thavala Hoeing weeding etc. & application of insecticides etc. & security. If the plant by die during maintenance. | 200 | Per Plant | 1,081.63 ₹2.2 L |
| 10.00 | Laying of lawns including ploughing levelling breaking of clods manuring & removal of stones etc. (Cost of manure of extra good earth to be paid separatley) Maintenance of lawns for 30 days of more till the grass forms a thick lawns free from weeds & fit for mowing in the duration of planting if lawn die some where the contractor will replant it at his own cost :In rows7. 5 Cms. apart in either direction. | 17,500 | Per100 Sq.m | 5,565.22 ₹9.7 L |
Updated dates
Tender Value
₹2.2 Cr
EMD Value
₹4.4 L
Closing Date
5 Mar 2026, 6:00 pmClosed
Project Director PMU(RWSRPD) and Chief Engineer
Office of the Project Director PMU(RWSRPD) and Chief Engineer Water Resources (North) Hanumangarh
Strengthening /up-gradation of infrastructure of HWMI Bikaner Demonstration Farm Ist Phase, For campus development/ land scape development horticulture /Garden development / Herbal Garden (P 462)
2026_WRDAS_535752_1
PMU_NIB_16_2025-26_02 and 03
Open Tender
Civil Works
90 days
Bikaner
As per bid documents
2 documents required · 2 mandatory
₹5,000
Executive Engineer Water Resource Division
₹4.4 L
Yes
Hanumangarh
17 Mar 2026
6 Feb 2026
6 Mar 2026
6 Feb 2026
5 Mar 2026
6 Feb 2026
6 Feb 2026 - 10 Feb 2026
10 Feb 2026
Cutting & clearance of jungle, bushes, shrubs Ankra/Ipomoea, Juliflora typna etc. on canal and bunds in dry/moist/slushy conditions including disposal as per instructions of the Engineer-in-charge. Cost of wood has been deducted from rates and thus will be property of contractor after cutting. thick
Cutting & clearance of jungle, bushes, shrubs Ankra/Ipomoea, Juliflora typna etc. on canal and bunds in dry/moist/slushy conditions including disposal as per instructions of the Engineer-in-charge. Cost of wood has been deducted from rates and thus will be property of contractor after cutting. ordinary
Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 meter in width as well as 10 Sqm. on plan including disposal of excavated earth upto 50 Mtr. and lift upto 1.5 Mtr. disposed soil to be levelled and neatly dressed: All kinds of soil.
Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish lead upto 50 Mtr. and lift upto 1.5 Mtr. : All kinds of soil.
Ploughing the existing ground to a depth of 15 cm to 25 cm and watering the same: All kinds of soil.
Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches removing the roots and stacking of serviceable material and disposal of unserviceable material :Beyond 30 cm girth upto including 60 cm girth.
Supply & Planting of shady plants (Neem, Peepal, Goolar, Jamun, Imili or other specified) along road side including the following activities : 1.Prepartion of soil including cleaning & revoving of unwanted shrubs removal of stones & garbage 2.Supply of plant at site of two years of age & height more than 1.50 Mtr.3.Supply of dry manure (Farm yard manure organic).4.Supply of insecticides .5.Digging of pits size 60×60×60 cms including remoal of tones, Manuring application of insecticides & watering at least 15 liter per plant after planting.6.Half brick Circular tree guard in second class bricks, internal dia 1.25 meter and height 1.20 meter above ground and 0.20 meter below ground bottom two courses laid dry and top three courses in cement mortar 1:6 (1 Cement : 6 Sand) and the intermediate course being in dry honey comb masonry, as per design complete.7.Watering to plants.8.Maintenance of plants by the contractor including pits, preparation of Thavala Hoeing weeding etc. & application of insecticides etc. & security. If the plant by die during maintenance contractor has to replace same height plant at his own cost..(without tree guard)
Supply & Planting of ornamantal plants (Kachnar, Amaltas, Gulmohar, Arjun, Kala Siris, Jacranda etc. or other specified)1.Prepartion of soil including cleaning & revoving of unwanted shrubs removal of stones & garbage 2.Supply of plant at site of two years of age & height more than 1.50 Mtr.3.Supply of dry manure (Farm yard manure organic).4.Supply of insecticides .5.Digging of pits size 60×60×60 cms including remoal of tones, Manuring application of insecticides & watering at least 15 liter per plant after planting.6.Half brick Circular tree guard in second class bricks, internal dia 1.25 meter and height 1.20 meter above ground and 0.20 meter below ground bottom two courses laid dry and top three courses in cement mortar 1:6 (1 Cement : 6 Sand) and the intermediate course being in dry honey comb masonry, as per design complete.7.Watering to plants.8.Maintenance of plants by the contractor including pits, preparation of Thavala Hoeing weeding etc. & application of insecticides etc. & security. If the plant by die during maintenance contractor has to replace same height plant at his own cost.(without tree guard)
Planting & Maintenance of shrubs.Planting of shrubs in central verge 1.Preparation of soil including cleaning & removing of unwanted shrubs removal of stones & garbage. 2.Supply of plant at site like Bouganvillia & Kankar.3.Supply of dry manure (Farm yard manure organic).4.Supply of Insecticides.5.Digging of pits size 60×60×60 cms including removal of stones, Manuring application of insecticides & watering at least 15 liter per plant after planting.6.Watering to plants. 7.Maintenance of plants by the contractor including pits, preparation of Thavala Hoeing weeding etc. & application of insecticides etc. & security. If the plant by die during maintenance.
Laying of lawns including ploughing levelling breaking of clods manuring & removal of stones etc. (Cost of manure of extra good earth to be paid separatley) Maintenance of lawns for 30 days of more till the grass forms a thick lawns free from weeds & fit for mowing in the duration of planting if lawn die some where the contractor will replant it at his own cost :In rows7. 5 Cms. apart in either direction.
Planting of trees/Shurbs/hedge & climbers plants at desired distance in a row & watering.
Planting permanent hedges including digging of trenches, 60 cmwide and 45 cm deep, refilling the excavated earth mixed with Planting permanent hedges including digging of trenches, 60 cm farmyard manure, supplied at the rate of 4.65 cum per 100 metres and supplying and planting hedge plants at 30 cm apart
Preparation of different sized beds as directed.
Supply of dry manure including loading unloading, transportation & stacking a site : Fram yard manure (organic).
Supply of dry manure including loading unloading, transportation & stacking a site Compost.
Supply of dry manure including loading unloading, transportation & stacking a site Goat dungmanure.
Supply & Stacking good earth at site complete including loading unloading & transporation etc.
Supply of different sized pots at site store including loading unloading & transporation etc. : Cement pot 350 mm size.
Supply of P.V.C. hose of different sizes at store including transportation etc. complete : 38 mm dia.
Supply of different varieties of Rose plants in polyethyene bags/earthen pots according to height growth & age of the plant at site including loading/ unloading & transportation etc. complete : Desi Rose / Root stock plants
Supply of different varieties of Rose plants in polyethyene bags/earthen pots according to height growth & age of the plant at site including loading/ unloading & transportation etc. complete :Ganganagari rose plant in poly beg
Supply of different varieties of palms in poly bags/earthen pot according to height growth and age of plant at site including loading unloading and transportation etc. completeRaffish palm 2 to 2.2 feet
Supply of different varieties of palms indoor plants in polyethyene bags/earthen pots according to height growth & age of the plant at site including loading/unloading & transportation etc. complete Desi Crotons.
Provision of engaging Gardener for maintaing lawn - Garde 1
Provision of engaging Casual Labour for maintaing & cleaning lawn (beldar/coolie/chowkidar/waterman/earthdresser)
Supply of different sized lawn mower including transportation etc. as store complete.Electric Lawn Mower sarfex 18 EL
Construction of tube-well from ground levels and upto 100 Meter depth and above to accommodate housing and assembly pipe of following sizes in all types of alluvium strata by percussion/ rotary drilling method and with gravel as per IS:4097-1967 and packing as per IS:2800 (Part I -& II) 1979 as amended upto date (the work includes the cost of gravel & its primary packing and packing during development, lowering of housing & strainer assembly pipes, with supply and wrapping of coir-rope, wherever necessary, for arresting fine sand particles. The work will not include cost of housing pipe and strainer pipe assembly and development work, but work would be completed after obtaining sand free water).250mm –do-.
Development of tube well as per IS specification using suitable compressor to give sand free water for required yield of the gravel packed tube well.
Supply of ERW M.S. black casing pipe ISI marked (IS:4270/1992) of grade Fe410 of following sizes at site of work.250 mm Nominal bore of pipe
Supply of strainer pipes made of ERW M.S. black pipe ISI mark of following sizes at the site of work including required size of slotting as per IS:8110-1985.250mm-do-.
S & F tube well cover of M.S.sheet (6mm thick) with nuts and bolts complete for casing size:250mm dia
S & F M.S. clamp, set of 50 ×6mm flat iron with nuts and bolts etc. for holding the riser pipe assembly of submersible pump set.
Installation of submersible motor pump set in Tube-well/open well complete ( labour charges only) including transportation of tripod, chain pulley block & any other material required for lowering purpose.
Construction of 185 cm. dia platform as per approved design and drawing of UNICEF.
Providing & lowering of G.I. Pipes, flange pipe including rubber washer and nuts of 8 mm dia complete in all respect I.S.1239 Marked.B Class 80 mm dia
Providing & lowering of G.I. Pipes, flange pipe including rubber washer and nuts of 8 mm dia complete in all respect I.S.1239 Marked. B Class 100 mm dia
SITC of Radial / mixed flow ISI marked water and anti-corrosive liquidfilled submersible motor pump sets suitable for 100/150mm diaborewell. The size of adopter fixed on top of the motor should exceedthe top of coupler , for safegaurd the coupler. The construction materialof motor and pump should match IS: 8034 : 2018 and IS: 9283 guideline.The radial flow pumpset should operate at 5 star energy efficiency level ofBEE and mixed flow pump set should operate at 3 star energy level ofBEE, accompained by valid BEE certificate. Motor should be IE2 class asper IEC 60034-2-1: 2007, IEC 60034-30: 2008, & IS12615:2011 withrequired accessories including making connection suitable for Bore well.The job includes labour part of lowering of riser pipe G.I./ H.D.P.E. withrope, cables & pump, installation of complete fitting and accessories,jointing of electrical cables up to Starter. All labour for testing ofsubmersible pumps set and supply of water to water mains, complete inall respect. OEM shall have submit NABL / CPRI / ERDA accrediated labtype test certificate before execution. All as per pre approved byEngineer in charge. For additional technical parameters of products/work , refer Annexure "A" attached with this BSR .150 mm diameter Submersible pump shall have following HP Rating, phase, Head range, Discharge range respectively.15.0 HP, 3-Ø, (80 - 123)Mtr, (465-305) LPM
Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-armouredCopper cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with electrolyticgrade Copper made of copper rods confirming to IS 613-1964, of purity >99.7%, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume /Stoneware / PVC pipe/ open duct/cable trench / Cable tray (with cable tie)including testing etc. as required of following size. OEM must have it's own inhouse NABL accrediated Laboratory for testing procedure as per IS:10810 Foradditional technical parameters of product / work, 10.0 Sq. mm 3 core
SITC of Single Stage, water cooled, High Speed (2880 RPM),Horizontal, Centrifugal, Openwell Submersible pumps set pre filledwith coolent water and fitted with mechanical seal - T/C Vs T/C,Thrust bearing shall be of carbon + S.S.The stator body of singleThrust bearing shall be of carbon + S.S.The stator body of singlephase pump shall be of SS and rest of all shall be of cast iron. Allcasting parts should be cathod electro deposition (CED) coated andother construction material should be confirming to IS : 14220:2018 . The overall performance of pump shall confirm to BEEenergy efficiency level of 3 star. Valid BEE certificate from OEMmust be submitted for the same. Motor should be IE2 class as perIEC 60034-2-1: 2007, IEC 60034-30: 2008, & IS12615:2011,including making connection etc as required complete in allrespect. OEM shall have submit NABL / CPRI / ERDA accrediatedlab type test certificate before execution. All as per pre approvedby Engineer in charge. For additional technical parameters ofproducts/ work , .5.0 HP, 3-Ø, (14 -28) Mtr, (995-500) LPM
Sump well Earthwork inexcavation in foundation, trenches etc. including dressing of sides and ramming of bottoms, including getting out the excavated material, refilling after laying pipe/ foundation and disposal of surplus excavated material at a lead upto 50m suitable site as per direction of Engineer for following depths, below natural ground / Road top level. nall types soils/saturated soil such as morrum,sand,sandy silt,clay,black cotton soil, kankar, etc. Depth upto 1.5 m
Providing and Laying in position of Cement concrete Nominal mix (1:3:6) including leads of all construction materials,curing,compaction and finishing with rendering in cements and mortar 1:3 (1 cement : 3 coarse sand) and making good the joints excluding the cost of centering, shuttering and reinforcement. Well graded crusher broken stone aggregate of maximum size upto; 20 mm
Brick masonry (using well burnt clay bricks of size 230x110x70mm, class designation 75 as per specification) upto plinth including all leads of all construction materials including curing etc. complete. © In cement sand mortar 1:5 Add extra if well burnt clay bricks (size230x110x70mm) class designation 100 as per specifications are to be used (a) Over Item No. 10
Providing and Laying in position of Cement concrete Nominal mix (1:2:4) including leads of all construction materials,curing,compaction and finishing with rendering in cements and mortar 1:3 (1 cement : 3 coarse sand) and making good the joints excluding the cost of centering, shuttering and reinforcement. Well graded crusher broken stone aggregate of maximum size upto; 20 mm
Plaster in cement sand mortar 1:4 including racking of joints, smooth finishing & curing etc. complete including all leads of all construction materials of thickness: 12 mm
Providing, Laying & Jointing R.C.C. class NP-2 Non-Pressure pipes (IS : 458mark) of approved make with collars, jointed with C.M. 1:2 or having Spigot and socket ends with flexible rubber rings joint including testing of joints etc. complete :300mm dia Internal
Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide
M-40,80mm thick to be used in medium- traffic ( Mediumtraffic is defined as a daily traffic of 150-450 commercialvehicles exceeding 30 KN laden weight, or an equivalent ofvehicles exceeding 30 KN laden weight, or an equivalent of0.5 to 2.0 MSA for a design life of 20 years.) like city streets,small and medium market roads, low volume roads, utility cutson arterial roads, etc Category A Denated units to key into each other on four faces zigzag shape as per IRC SP 63:2004
Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos /Lindane emulsifiable concentrate of 20%
Screen Filter 25 m3/hr - PP
Sand Filter with Back wash assembly 25 m3/hr
Air release Valve 1"
Pressure Gauge 2" (Glycerin Filled)
Butterfly Valve - 2"
NRV, Low Friction 2' "
Header Assembly - 2"
Fertilizer Injector 3/4" with Assly
PP Ball Valve 63 mm
PP Ball Valve 40 mm
S80 PL 2" A-BSP QRV PPY 2w-c 2"
PVC Pipe 110 mm; Class II; 4 kg / cm2 (IS: 4985
PVC Pipe 90 mm; Class II; 4 kg / cm2 (IS: 4985)
PVC Pipe 63 mm; Class II; 4 kg / cm2 (IS: 4985)
PVC Pipe 40 mm; Class II; 4 kg / cm2 (IS: 4985)
butterfly Control Valve 110MM
butterfly Control Valve 90MM
Flush Valve 90MM
Flush Valve 63MM
Flush Valve 40MM
Lateral 16 mm; Class II; 2.5 kg / cm2
Lateral inline 16 mmx 30cm x 2lph
PC j dripper 8LPH
Rubber Grommet - 16mm
Start Connector / Take Off - 16x16
End Cap - 16mm
Nipple / Jointer / Connector - 17x17
POP up sprinkler
Fitting & Accessories
Installation Charge
Earthwork inexcavation in foundation, trenches etc. including dressing of sides and ramming of bottoms, including getting out the excavated material, refilling after laying pipe/ foundation and disposal of surplus excavated material at a lead upto 50m suitable site as per direction of Engineer for following depths, below natural ground / Road top level. nall types soils/saturated soil such as morrum,sand,sandy silt,clay,black cotton soil, kankar, etc. Depth upto 1.5 m
Filling available excavated earth (excluding rock) in trenches, plinth side of foundation etc in layer not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering including lead up to 50m and lift up to 1.5m
Providing and Laying in position of Cement concrete Nominal mix (1:4:8) including leads of all construction materials, curing, compaction and finishing with rendering in cement sand mortar 1:3 (1 cement :3 coarse sand) and making good the joints excluding the cost of centering, shuttering and reinforcement. Well graded crusher broken stone aggregate of maximum size upto; 40 mm
Brick masonry (using well burnt clay bricks of size 230x110x70mm, class designation 75 as per specification) upto plinth including all leads of all construction materials including curing etc. complete. © In cement sand mortar 1:5 Add extra if well burnt clay bricks (size230x110x70mm) class designation 100 as per specifications are to be used (a) Over Item No. 10
Brick masonry (using well burnt clay bricks of size 230x110x70mm, class designation 75 as per specification) upto plinth including all leads of all construction materials including curing etc. complete. © In cement sand mortar 1:5 Add extra if well burnt clay bricks (size230x110x70mm) class designation 100 as per specifications are to be used (a) Over Item No. 10 Add extra for superstructure brick masonry on item no 10
Centering and shuttering for slabs, beams, lintels Columns, trough with or without caps and base including propping and removing
Providing and Laying in position of Cement concrete Nominal mix (1:1.5:3) including leads of all construction materials, curing, compaction and finishing with rendering in cement sand mortar 1:3 (1 cement : 3coarse sand ) and making good the joints excluding the cost of centering, shuttering and reinforcement. Well graded crusher broken stone aggregate of maximum size upto; Extra labour charges for RCC due to obstruction in laying and placing the Columns, slabs, cantilevers projections stair cases, lintels, beams, chajjas, Retaining walls, piers, abutments, galleries, arch covers, bed plates, sluice capstan bases etc.
Supplying of M.S. reinforcement including labour charges for bending binding and placing in position all reinforcement as per drawing including cost of binding wire and all leads and lifts using. Tor or ribbed bars (IS :1786)
Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes Type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make 110 mm dia
Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make Bend 87.5 Dg. 110mm dia
Plaster in cement sand mortar 1:5 including racking of joints, smooth finishing & curing etc. complete including all leads of all construction materials of thickness: 12 mm
Supply and fixing machine cut fine dressed Red/Pink sand stone dasa or coping with full moulding if required laid on cement mortar 1:4 including pointing with admixture of pigment matching with the stone shade 50mm thick.
Cement concrete flooring grade 1:2:4 (1 cement, 2 course sand, 4graded stone aggregate) rounded off edge etc. but excluding the cost of nosing etc. complete, 40 mm thick with 20 mm nominal size aggregate.
Construction of soakage well in all type of soil with 300 mmthick dry masonry, top and bottom 300 mm course in CM 1:6,80mm thick stone slab, jointing of slab in CM 1 : 3, Ralthal,Kharanja, 40 mm thick M-15 grade C.C flooring , earthwork complete as per approved drawing including disposal of earth within a lead of 50 mtr.: Size 300 Cm. dia outside & 300 Cm. depth
Providing and fixing welded mesh/expanded metal mesh in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. complete (excluding frame work) of size. Welded mesh 25mmx25mmx2.10mm
Providing and fixing T-iron frames for doors window and ventilators of mild steel tee-sections, joints mitered and welded with 15x3 mm lugs 10 cm long embedded in cement concrete blocks 15 x 10 x 10 cm of 1:3:6 (1 cement :3 course sand : 6 graded stone aggregate 20mm nominal size) or with wooden plug and screw or rawl plugs and screws of with fixing clips or with bolts and nuts as require including fixing of necessary but hinges and screw and applying a priming coat of approved steel primer.
Providing and fixing M.S. sheet 1mm thick single leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chowkhats: including two coats of anit-corrosive red oxide primer paint (a) Single leaf shutters
Providing and fixing M.S. sheet 1mm thick single leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chowkhats: including two coats of anit-corrosive red oxide primer paint (b)Add extra for double leaf shutters.
Colour washing of all shades to give an even shade including all scaffolding : New work (two or more coats) with a base coat of whiting
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work
P & F Indian type white glazed vitreous china Ist quality WC Orissa pan (IS : 2556 Mark) with 100 mm vitreous China p or S trap including cutting and making good the wall and floor/ Size 580 x 440 mm
P & F G I pipes (External works) with G I fitting ( IS: 1239 Mark) including trenching & refilling earth etc. 15 mm dia nominal bore Class - B
P & F G.I. Pipes (External Work) with G.I. fittings excluding union (IS : 1239 Mark) including trenching & refilling earth etc.: 25 mm dia nominal bore class-b
P & F Bib cock ( IS:8931 Mark), Superior quality of approved make. ( Brass 400 gm, 15 mm nominal bore)
P & F Storage tank ( IS : 12701 marked indicated the BIS license No), approved make with cover, 25 mm dia IM long G I over flow pipe & 25 Cm long wash out pipe with plug & socket, including making connection etc. complete of approved design. ( 500 ltrs)
P & F Flush Cock/flush valve ( IS:9758 Mark) for W/C of approved quality make.CP brass half turn Exposed 25 mm nominal bore.
Providing and Laying and jointing Glazed S W Pipe grade A ( IS 651 marked) of approved make with spun yarn and stiff mixer of cement mortar 1:1 excavation and refilling of earth in all type of soil upto 1.20 mtr depth S W fitting including testing of joints etc complete. 100 mm dia
Providing & Laying C.C. 1:5:10 (Stone aggregate 40mm nominal size) all around S.W. pipe including 15 Cm. thick bed concrete (Width W= Diameter of pipe in Cm+30 Cm.)( Excluding cost of pipe) 100mm dia S.W. Pipe.
Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 Itr/sq.mt. by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ltr and viscosity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under Joint strength in longitudinal and transverse direction at 23°C as 650/450N/5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D-5147. The laying of membrane shall be got done through the authorized applicator of the manufacturer of membrane. 3 mm thick
Grading roof for water proofing treatment with water proffing compound 10.17.1 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
Making khurras 450 x 450mm with average minimum thickness 50 mm cement concrete 1:2:4 over P.V.C. Sheet 1 Mtr. x 1 Mtr. x 40 micron finished with 12 mm cement plaster 1:3 and one coat of neat cement, rounding edges and making and finishing the out let complete.
Supplying and fixing rolling shutters of approved make, made of 80 x 1.25mm. M.S. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including cost of spring hooks, providing and fixing necessary 25.3cm. long wire springs grade No. 2 and M.S. top cover 1.25mm thick for rolling shutters as per design & IS 6248- 1979. (Clear openable area to be measured for payment).
Providing corrugated G.S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape whenever required :1.00 mm thick with zinc coating not less than 275 gm/m2
Steel work in built up tubular trusses including cutting, hoisting (height upto 10 m) fixing in position and applying a priming coat of approved steel primer, welded and bolted including special shaped washers etc. complete :Hot finished welded type tubes
Providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section (IS 1038- 1983) joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 5x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required : Windows side hung /Ventilators top or centre hung (openable)
Wiring of light point/fan/exhaust fan point/cell bell with 1.5 sq. mm FR PVC insulated unsheathed flexible copper conduct 1.1 KV grade and 1.50 sq mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 KV grade (IS 694) of approved make in surface/recessed ISI marked (MMS (IS:9537 P-III) PVC conduit & its accessories round tiles 18 SWG MS box with earth terminal 6A switch, 3mm thick phenolic laminated sheet zinc plated/brass screws cup washers making connections testing etc as required.
i- shortpoint (upto 3 Mtr)
ii- medium point ( Upto 6 Mtr)
iii- long point (Upto 10 mtr)
Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419- 1988)accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal, 10 A modular switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories For additional technical parameters of product / work , On board
Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947- 2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work, 50/63 A rating
P & F 1.2mm thick M.S. Recessed fan box, hexagonal/ round of size 130mm dia, depth 75mm, 12 mm dia rod fan hook with 100 mm lengthextended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work.
Providing & Fixing of energy efficient /energy saving IP 20 LED direct retrofit Bulb in existing holder or fixture as required with system lumen efficacy ≥100 lm/Watt output pf 0.95, CRI >70, minimum life time of minimum 25000 Burning Hours with , 70% of intial Lumen maintaned till ife ends, CCT 3000°K / 4000'K 5700K /6000"K/6500'K (As per ANSI Bin) maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( TC). Manufactures word mark/name Engraved/embossing/screen painting on housing OEM must have its own in house NABL lab setup for all testing facilites for LED fixtures (LM 79/LM80 ) certificate/report from OEM shall be submitted. All as per pre approved by engineer in charge for additional technical parameters of product/ work, 15 Watt
Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass cover and secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current <750mA. The luminaire shall be BIS certified and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name ngraved/ Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with LED Street Light fixture with Minimum lumen output 7500 lm
P & F paper phenolic resin bonded laminates confirming to IS : 2036 - 1995 for boxes/ frames including making holes for switches etc, with brass screws, washers/ zinc plated nut and bolts as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 4.8 mm thick
Providing & Fixing of ISI marked (IS:1258) batten/angle lamp holder with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screwsincluding making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work.
Providing & Fixing of IS 11037:1984 marked non modular socket size flush type 120 watt rotary minimum 5 step fan regulator with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material including making connection testing etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work.
Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work, 3x 2.5 sq mm
Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work , Metal door (single phase) IK-09 and IP-43 with Metal end box 8 Way (8+2)
Providing & Fixing of double ball bearing, copper wounded capacitor start single phase metallic blade fresh air fan, in existing opening including cost of hardware, flexible 3 core copper conductor ,making connections, testing etc. as required. OEM shall be an ISO certified company. Appropriate OEM test certificate shall be submitted by contractor. All as per in charge. For additional pre approved by Engin technical parameters of products/ work. 225 mm sweep
Supply and Installation of solar pump with universal controller ( SPV submersibble pump water filled motor) AC manual 7.5HP including necessary Structure and Solar panel as specified in specification complete in all respect including 5 year warrenty.
Providing, lowering, laying and jointing in trenches, standard lengths HDPE ISI marked Pipes as per IS-4984: 1995 (amended up to date) with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges,stacking of pipes, including cost of labour and material, specials (Tee,bend etc.), satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineerin-charge of following class and diameter. (excluding earth work) .Note : Providing and fixing of all requisite specials as per drawing,design and layout are inclusive in RM measurement of the item and shall not be paid separately.Supply may be in coil or straight length in 6 M/12 M. All kinds of soil HDPE PE-80 PN-6 90 mm dia
Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr. including required all safety provisions etc.:All kinds of soil
Establishment of Poly hose/Green house as per Horticulture Department Specification complete in all respect ( size 36 m x 56 m)
Establishment of shade Net house tubular (High cost model) design Type 1 as per Horticulture Department Specification complete in all respect ( size 36 m x 60 m)
Beldar (Labour for Running of Poly house and shed net @ 5 Nos per year for 2 years)
Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos /Lindane emulsifiable concentrate of 20%
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.77 MB
BOQ_954341.xls
BOQ • 0.36 MB
BidP462V4.pdf
Tender Documents • 4.04 MB
Download all tender documents and submit your bid