Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹27.4 LAccepted-AOC | ₹27.4 L Quoted ₹27.9 L | L-1 | Accepted-AOC L-1 |
| 2 | L-2₹28.5 L+₹63,762.37 (2.29%)Rejected-Finance | ₹28.5 L+₹63,762.37 (2.29%) | L-2 | Rejected-Finance L-2 |
| 3 | L-3₹28.9 L+₹1.0 L (3.75%)Rejected-Finance | ₹28.9 L+₹1.0 L (3.75%) | L-3 | Rejected-Finance L-3 |
| 4 | L-4₹29.3 L+₹1.4 L (4.97%)Rejected-Finance | ₹29.3 L+₹1.4 L (4.97%) | L-4 | Rejected-Finance L-4 |
| 5 | L-5₹29.8 L+₹1.9 L (6.97%)Rejected-Finance | ₹29.8 L+₹1.9 L (6.97%) | L-5 | Rejected-Finance L-5 |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
9 Feb 2024, 6:00 pmClosed
GE (AF) FARIDABAD
GE (AF) FARIDABAD
SPECIAL REPAIR TO MES SUBSTATION AND PUMP HOUSE AND PROVN OF POL STORAGE SHED, CHEMICAL EARTHING, COVERS FOR SWT NEAR REGIMENTAL COMPLEX AT AF STN NARAINA (HILL TOP) IN AOR GE (AF) FARIDABAD
2023_MES_632737_2
GE (FBD)/AF-63/2023-2024
Open Tender
Civil Works
Item Rate
180 days
NARAINA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) FARIDABAD
₹84,000
Yes
9 Apr 2024
20 Jan 2024
12 Feb 2024
20 Jan 2024
9 Feb 2024
27 Jan 2024
20 Jan 2024 - 23 Jan 2024
Amount
Surface dressing n exc 15 cm deep in hard/dense soil complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches, not exceeding 1.50 m wide and not exceeding 1.5 m in depth etc not exceeding 10 Sqm on plan for shafts, cesspits, manholes, pier holes, founddaton etc and getting out in hard /dense soil complete all as specified and directed by Engineer-in-Charge.
Demolition/Dismantling of Brickwork or stone/ boulder masonry, built in cement mortar incl all quoins, arches, pillars, etc, complete all as specified and directed by Engineer-in-Charge.
M&L for Brickwork with subclass 'B' bricks (old size bricks), straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed by Engineer-in-Charge.
All as per item No 04 above but except bricks
M&L for brick work with sub class ‘B’ bricks (old size brick) straight or curved on plan to any radius in half bricks thick walls, built in CM 1:4 complete all as specified and directed by Engineer-in-Charge.
Taking down cement plaster of any description on concrete surfaces such as soffit of RCC slab, chajjas and brick walls, Ceiing etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 15 mm thick cement plaster in CM 1:6 on brick Work or concrete surfaces including finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L, Rendering 15mm thick in CM 1:4 on of brick work or concrete surface finish ever and smooth w/o using extra cement incl WPC @ 3% weight of cement complete all as specified and directed by Engineer-in-Charge.
Supply only liquid WPC complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 10mm thick in CM 1:3 over concrete surface as on ceiling, chhajja, shelves etc to match with existing surfaces finish even and smooth w/o using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new plaster surface & apply two coats of cement based paint over a coat alkali primer resistance incl one layer of 3mm thick wall care compound of putty on old scraped surfaces or new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and directed by Engineer-in-Charge.
M & L for preparation of new plastered surface and applying two coats of oil emulsion distemper on wall over one coat of primer incl one layer of 3mm thick wall care compound of putty on old scraped surfaces or new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and directed by Engineer-in-Charge.
M & L for preparation of new plastered surface and applying two coats of oil emulsion distemper on ceiling over one coat of primer incl one layer of 3mm thick wall care compound of putty on old scraped surfaces or new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and directed by Engineer-in-Charge.
M&L for two coat of Acrylic smooth exterior emulsion paint over one coat of acrlic primer incl one layer of 3mm thick wall care compound of putty for exterior/interior on old scraped wall/ceiling surfaces or new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and directed by Engineer-in-Charge. Note : Colour as approved by Engr-in-Charge.
M&L for one coat of Acrylic smooth exterior emulsion paint over one coat of acrlic primer incl one layer of 3mm thick wall care compound of putty for exterior/interior on old scraped wall/ceiling surfaces and obtain smooth finish using sand paper complete all as specified and directed by Engineer-in-Charge. Note : Colour as approved by Engr-in-Charge.
M&L for preparation of old surfaces by removal of existing treatmen and applying two coats of oil emulsion distemper over a coat of primer on surface of walls incl one layer of 3mm thick wall care compound of putty on old scraped surfaces or new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old surfaces by removal of existing treatment and applying two coats of distemper oil emulsion on ceiling over one coat of primer incl one layer of 3mm thick wall care compound of putty on old scraped surfaces or new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old surfaces by removal of existing treatmen and applying one coats of oil emulsion distemper over a coat of primer on surface of walls incl one layer of 3mm thick wall care compound of putty on old scraped surfaces or new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old surfaces by removal of existing treatment and applying one coats of distemper oil emulsion on ceiling over one coat of primer incl one layer of 3mm thick wall care compound of putty on old scraped surfaces or new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old surfaces by removal of existing treatmen and applying two coats of white wash on surface of wall complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old surfaces by removal of existing treatmen and applying two coats of white wash on surface of ceiling complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new steel or iron surfaces of any description not otherwise described over 10 cm girth or width and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old steel or iron surfaces of any description, n exc 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed by Engineer-in-Charge.
M & L for one coat of synthetic enamel paint on steel surface including preparation of old steel surface width or girth exc 10cm complete all as specified and directed by Engineer-in-Charge.
M&L for repair of RCC slab, beam, chajja, facia etc by removing of old portion of concrete and cleaning/brushing and removing of loose concrete/applying required cement slurry @ 3.5 kg/sqm making good with concrete 1:1.5:3 and applying 3 mm thick cement mortar 1:4 and finish the surface complete all as specified and directed by Engineer-in-Charge. (Note length of fins, facias shall be measured irrespective of any thickness and height).
M&L for non skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular ) area of each tile exc 0.11 sqm but n.exc 0.18 sqm, in floors of shade & designed as approved by GE,set and jointed in neat cement slurry and pointed with white cement with colour pigment to match the colour of tiles,15 mm thick rendering in bedding layer or screed bed in cement mortar (1:6) in floors etc complete incl dismantling/demolition of floor/tiles etc complete all as specified and directed by Engineer-in-Charge.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular ) area of each tile exc 0.11 sqm but n.exc 0.18 sqm, in dado of shade & designed as approved by GE,set and jointed in neat cement slurry and pointed with white cement with colour pigment to match the colour of tiles,15 mm thick rendering in bedding layer or screed bed in cement mortar (1:6) in floors etc complete incl dismantling/demolition of floor/tiles etc complete all as specified and directed by Engineer-in-Charge.
M&L for Glazed ceramic jointless light/coloured group of size 300/350mmx450/600mm, thickness not less than 6mm as in vertical surfaces such as skirting/dado etc., set and jointed in neat cement slurry and pointed with white cement and pigment to match, laid over and including 10mm thick plastering in cement mortar 1:4, incl dismantling tiles etc complete all as specified and directed by Engineer-in-Charge. Note : Shade & design as approved by GE.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc.laid, bedded and pointed in any mortar complete all as specified and directed by Engineer-in-Charge.
M&L rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed by Engineer-in-Charge.
M&L for Granite 16-20mm thick (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms, wash basin platform and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite incl moulding ,rounding of edgeing and dismantling complete all as specified and directed by Engineer-in-Charge.
M&L for Marble work of any shade other than white and black 16 to 20mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble complete all as specified and directed by Engineer-in-Charge.
Taking down existing roof treatment of any description and any type complete all as specified and directed by Engineer-in-Charge.
M&L, Rendering 15mm thick in CM 1:4 on of brick work or concrete surface finish ever and smooth w/o using extra cement incl WPC @ 3% weight of cement at any height etc complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of roof surface & applying evenly a tack coat of industrial bitumen 85/25 grade @ 1.2 Kg/Sqm including APP based polymeric membrane minimum weighing 3.6 kg/sqm and minimum 3 mm thick reinforced wih polyster non wove fabric (wt not less than 150 gms/sqm) land on primed surface by forced application, joints to be touched hot and width of overlaps not be less than 150 mm complete all as specified and directed by Engineer-in-Charge.
M&L for PCC (1:2:4) nominal mix, type B-0, using 12.5mm graded stone aggregate in roof padding and surface finished even and smooth without using extra cement, complete all as specified and directed by Engineer-in-Charge.
M&L for Making benching with PCC (1:2:4) type B0 using WPC @ 3% weight of cement along side wall adjoining to roof in concave shape complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:2:4 type B0 (using 12.5 mm graded stone aggregate) as in coping/benching and all other similar works including necessary formwork complete all as specified and directed by Engineer-in-Charge.
Removing plants / sherbs duct wall , junction with roots using herbicide chemical of existing brick or concrete for multistoried building at any storeyed and any height and match the surface with existing surface using 1:3 CM, complete all as specified and directed by Engineer-in-Charge.
Taking down chowkahts or frames with shutters (without taking off shutters from the frame) not exceeding 1.5 Sqm each and complete all as specified and directed by Engineer-in-Charge.
Taking down chowkahts or frames with shutters (without taking off shutters from the frame) exceeding 1.5 Sqm but not exceeding 4 sqm each and complete all as specified and directed by Engineer-in-Charge.
M&L for pressed steel frames of size 105mmx60mm for doors with one or more rebates fabricated out of 1.25mm thick mild steel sheets including necessary fixing lugs, butt hinges (100mm medium weight-03 Nos), lock strike plate with and including filling of hollow portion in PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate and making good the existing surface in cement mortar 1:6, complete all as specified and directed by Engineer-in-Charge.
All as per item No 43 above item but here-in size of frame 125mmx60mm for doors complete all as specified and directed by Engineer-in-Charge.
S&F for 30mm thick flush shutters, solid core construction, with particle board core and plywood face panels, commercial type on both sides and one face is covered with decorative face veneer with lipping/frame to match complete all as specified and directed by Engineer-in-Charge.
S&F for 2nd class H.W. glazed and skelton door shutters 30mm thick, open rebated and prepared to received glass/gauge etc (without sash bars) edges of framing plain, chamfered or rounded and mitred , beads for securing glass etc the size of member of shutter as specified in SSR part-I clause 8.23(b) and fitted to chowkahts incl stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples or wooden beads etc complete all as specified and directed by Engineer-in-Charge.
S & F solid PVC door frame of size 50 x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube incl taking down old frame any type complete all as specified and directed by Engineer-in-Charge.
S&F in repair for CP fancy type 100 mm size chromium plated shower roses with or without swivel joints ,any size including connecting Rod and fixing to steel pipe or union complete all as specified and directed by Engineer-in-Charge.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails MS frame shall be convered with heat moulded plain colour PVC `C' channel having a PVC sheet strip of 20 mm width stuck inside with solvant cement for stiles and plain colour PVC sheet top rail, lock rail and bottom rail on either side and as gap insert of top rail and bottom rail; paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles and raials with suitabale PVC sheet beading, and jointed together with solvant cement, fixing in the frame at side as per specification and drawing incl 3Nos- 100mm Aluminium hinges for each shutter complete all as specified and directed by Engineer-in-Charge.
M&L for factory made box type steel windows, 16 gauge steel section for frames & shutters, as per TD drawing No.219, sheet 01/03 to 03/03, using ERW hollow 'P' section comprising double frame for glazed and gauged skelton shutters jointed internally with flat iron 40X4 mm complete including grill of 10 mm square bar, fixed horizontally @ 10 cm centre to centre, pintel hinges 75 mm long 12 mm dia, 100 mm long handle, 150 mm long tower bolts, lugs etc. with/ without cooler provision, complete all as specified and directed by Engineer-in-Charge. Note :- (i) For purpose of measurement and payment double shutter with frame including square grill shall be considered as one unit. (ii) Glazing and wire mesh shall be measured and paid for separately in respective of item. (iii) Item includes cost of double shutter of gauged and glazed shutter with square bar grill.
S & F steel ventilators, fixed type,with glazing bars complete all as specified and directed by Engineer-in-Charge.
S & F for 3mm thick sheet glass ordinary quality glazing with oil putty in square n exc 0.5 sqm quality or description from steel frame and complete all as specified and directed by Engineer-in-Charge.
S & F for mild steel framed work as in grill, guard bars etc with ends of bars/FI shoulders and or riveted or forged in to spikes, framed guard bar and similar works confirming to Fe 410-0 or Fe 310-0 complete all as specified and directed by Engineer-in-Charge.
S & F for stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples or wooden beads complete all as specified and directed by Engineer-in-Charge.
S & F in repair 3mm thick sheet glass, ordinary quality and with oil putty in Square n. exc 0.5 sqm in each pane incl hacking out old broken glass from metal frame incl punching or drilling out old glazing pins/spring clips and glazed with oil putty complete all as specified and directed by Engineer-in-Charge.
S&F for MS butt hinges, medium weight, cold rolled mild steel 100mm long (ISI Marked) with welded or complete all as specified and directed by Engineer-in-Charge.
S&F for aluminum anodized barrel tower bolts of extruded section 150mm long (ISI Marked) complete all as specified and directed by Engineer-in-Charge.
S&F for aluminum handles cast type anodized 200mm long (ISI Marked) complete all as specified and directed by Engineer-in-Charge.
S&F for 250mm long aluminium alloy, anodised, sliding door bolt of 16mm dia with hasp, staple (bolt type) and fixing clips of sheet, extruded sections and fixing bolts and sliding bolts of extruded sections complete all as specified and directed by Engineer-in-Charge.
M & L for viterous china squating pan of (Orrissa Pattern) size 580x440 mm white with 'P' or 'S' trap front or back inlet and integral foot rest (excluding flushing cisteern and flush pipe) fixed in repair including lime concrete bedding as required set complete all as specified and directed by Engineer-in-Charge.
S&F in repair of PVC flushing cistem low level white with all accessories of 10 ltrs capacity incl flushing pipe, brackets and taking down of old CI/PVC flushing cistern complete all as specified and directed by Engineer-in-Charge.
S&F in repair for Vitreous China wash basin , White, flat back, size 550x400 mm excluding taps, waste, chain and plug and porcelain stopper but including brackets complete all as specified and directed by Engineer-in-Charge.
S & F in repair Bib tap CP fancy type long body 15 mm bore with will crutch or buttewrfly handle screwed down screwed to iron pipe complete with all fittings complete all as specified and directed by Engineer-in-Charge.
S & F in repair Stop cock /angle CP fancy type 15 mm bore screwed down high pressure with crutch or butterfly handle & screw both end for iron pipe or for Unions complete all as specified and directed by Engineer-in-Charge.
S & F in repair Stop cock concealed long shank chromium plated fancy type 15 mm bore screwed down high pressure with crutch or butter fly handle complete all as specified and directed by Engineer-in-Charge.
S& F for swan neck pillar cock fancy type chromium plated screw with iron pipe incl all fittings in repairs complete all as specified and directed by Engineer-in-Charge.
S&F for Towel Rail 600mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 190gms) complete all as specified and directed by Engineer-in-Charge.
S&F for Soap dish, fixed to plugs with chromium plated brass screws complete all as specified and directed by Engineer-in-Charge.
S&F for PVC connections 60cm long superior quality with PTMT nut on both side complete all as specified and directed by Engineer-in-Charge.
S&F in repair grating round 125mm size of CP complete all as specified and directed by Engineer-in-Charge.
S&F stainless steel pegset of six suitable size of length complete all as specified and directed by Engineer-in-Charge.
Taking up or down 15 mm dia bore steel tubing and connection including cleaning for refixing complete all as specified and directed by Engineer-in-Charge.
S&F for GI tubing 15mm bore medium grde with all fittings and fixed complete to wall and ceiling or laid in floors etc incl cutting chases in brick wall pinning in making good in CM 1:3 to facings where required complete all as specified and directed by Engineer-in-Charge.
Taking up or down steel tubing and connection including cleaning for refixing or removed to store, 20 mm dia bore complete all as specified and directed by Engineer-in-Charge.
S&F GI tubing 20 mm bore medium grade medium grde with all fittings and fixed complete to wall and ceiling or laid in floors complete all as specified and directed by Engineer-in-Charge.
Taking up or down steel tubing and connection including cleaning for refixing , 25 mm dia bore complete all as specified and directed by Engineer-in-Charge.
S&F GI tubing 25 mm bore medium grade medium grde with all fittings and fixed complete to wall and ceiling or laid in floors complete all as specified and directed by Engineer-in-Charge.
M & L for 50 mm thick PCC 1:3:6 type C-2 (using 40 mm agg. ) as in plinth protection / path/ any paved area complete all as specified and directed by Engineer-in-Charge.
S&F in repair for 100mm bore Cast iron soil, waste and vent pipes, in any length with or without ears, with cement joints, laid in trenches or in floors incl taking down old pipe complete all as specified and directed by Engineer-in-Charge.
S&F in repair for 100mm bore Cast iron soil, waste and vent pipes, in any length with or without ears, with cement joints, fixed to walls etc incl taking down old pipe complete all as specified and directed by Engineer-in-Charge.
S&F in repair for 75mm bore Cast iron soil, waste and vent pipes, in any length with or without ears, with cement joints,laid in trenches or in floors etc complete incl taking down old pipe complete all as specified and directed by Engineer-in-Charge.
S&F in repair for 75mm bore Cast iron soil, waste and vent pipes, in any length with or without ears, with cement joints, fixed to walls etc complete incl taking down old pipe complete all as specified and directed by Engineer-in-Charge.
S&F in repair for 100mm bore CI bends (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified and directed by Engineer-in-Charge.
S&F in repair 75mm bore CI bends (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified and directed by Engineer-in-Charge.
S& F in repair for 75 Cast Iron Cowl complete all as specified and directed by Engineer-in-Charge.
S&F in repair Stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed by Engineer-in-Charge.
M&L for repairs to sliding door bolt, hinges, pintel, locking arrangment, spike, roller, roller rails etc of steel gate/Wicket gate including welding /reveting to bring the steel gate /wicket gate in service condtions etc complete all as specified and directed by Engineer-in-Charge.
Repair to rolling shutter including necessary gressing, welding, locking arrangement including serviceing to gear box etc complete as to bring in service condtions etc complete all as specified and directed by Engineer-in-Charge.
Dismantling of fencing post or strut (wood, steel or RCC) any section, posts embeded in concrete, brick work, masonery etc, including taking out embeded portion in concrete, and making good disturbed ground complete all as specified and directed by Engineer-in-Charge.
Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in & ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface complete all as specified and directed by Engineer-in-Charge.
M&L cement concrete (1:3:6) type C1 (20mm graded stone Agg.) as in embedding of angle iron post complete all as specified and directed by Engineer-in-Charge.
Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out soft/hard dense soil, returning, filling in & ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface complete all as specified and directed by Engineer-in-Charge.
M&L cement concrete (1:4:8) type D2 (40mm graded stone Agg.) as in foundations, filling and mass concrete and embedding of angle iron post complete all as specified and directed by Engineer-in-Charge.
Supply only MS Galvanised chain link fencing including line wires, any mesh, size 75 x 75 and type to any type of standards, rails straining bolts, etc including provision of binding wire complete all as specified and directed by Engineer-in-Charge.
All as per item No 95 above but fixing only complete all as specified and directed by Engineer-in-Charge.
M&L for mild steel work as angles / conduit pipes in posts and struts in fencing / gates including cutting fixing tops to shape as directed, drilling holes, notching for wire, etc flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or riveting and similar work conforming to Fe 410-0 of (Gde E-165) complete all as specified and directed by Engineer-in-Charge.
S&F for Mild steel screw bolts 5 to 10 diameter of neck (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be tted with washers and one hexagonal or square nut, exc 5 cm long but n ecx 10 cm long complete all as specified and directed by Engineer-in-Charge.
S & F for mild steel framed work as in grill, guard bars etc with ends of bars/FI shoulders and or riveted or forged in to spikes, framed guard bars, barred iron doors, ladders, frame work of watertanks and and similar works confirming to Fe 410-0 or Fe 310-0 complete all as specified and directed by Engineer-in-Charge.
S& F for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and directed by Engineer-in-Charge.
S & F for welded wire mesh, exc 4 kg weight per square meter, cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel stables supplid and fixed complete to wood or steel members complete all as specified and directed by Engineer-in-Charge.
S&F for rolled sections as in main and cross beams, hip and jack rafters truss purlins where connected to common rafters and running rails, cleat or other connecting plates cutting, welding including Nut bolts, Fe 410-W (Gde -E-250) quality A complete all as specified and directed by Engineer-in-Charge.
S&F for pre painted galvalume aluminium zinc coating GI based corrugatd steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall fixed with self tapping screws complete all as specified and directed by Engineer-in-Charge.
S & F for 600x600mm plain board panel for ceiling 4.0 to 8.0 mm thick and incl necessary Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre incl dismantling of walls and ceiling board any type complete all as specified and directed by Engineer-in-Charge.
Dismantling fencing wire mesh,any type complete all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15cm thickness (below or above ground level) including floor finishes/tiling work and disposal of debris complete all as specified and directed by Engineer-in-Charge.
M&L 75mm thick PCC type D-2, 1:4:8 (using 40mm graded stone aggregate) as in sub base complete all as specified and directed by Engineer-in-Charge.
M&L for sand filling under floors or in foundation including watering and consolidation complete and complete all as specified and directed by Engineer-in-Charge.
M&L for 60 mm thick machine pressed and machine cut precast concrete inter locking paver block with grey cement and pigment (confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade) any clours complete all as specified and directed by Engineer-in-Charge.
M&L for 60 mm thick machine cut precast concrete inter locking paver block except tile ,(M-35) grade any clours complete all as specified and directed by Engineer-in-Charge.
M&L for 80 mm thick machine pressed and machine cut precast concrete inter locking paver block except tile ,(M-40) grade any clours complete all as specified and directed by Engineer-in-Charge.
M&L for sand filling under floors or in foundation including watering and consolidation complete all as specified and directed by Engineer-in-Charge.
M&L for machine pressed chequered tiles of size 300 x 300 x 25 mm thick (colour and glazed approved by EIC) with grey cement and pigments laid over 15 mm thick screed bed in CM 1:6 bedded and jointed in neat cement slurry, incl dismantling complete all as specified and directed by Engineer-in-Charge.
M&L for 25 mm thick PCC type B-0, 1:2:4 (using 12.5 mm graded stone aggregate) as in laying of floor/sub base finishes complete all as specified and directed by Engineer-in-Charge.
Removing/getting out of excavated material/spoils/debbries dumped at site to a distance exceeding 1.5 km but n exc 5 km and depositing where directed at a level n. exc 1.50 m above the starting point complete all as specified and directed by Engineer-in-Charge.
Remoing excavated soil to a distance not exceeding 40m and depositiing where directed at a level not exceeding 1.5 km above the starting point complete all as specified and directed by Engineer-in-Charge.
Returning filling in and including spreading levelling watering and well ramming in layers n exc 25cm thick complete all as specified and directed by Engineer-in-Charge.
M&L for Design ,development ,supply commisiong and testing EHCC certified ground tubular effective chemical earthing (CPRI tested for 15 KA current capacity for LT line ) highly anticorrosive long life eletrode with and including adequate protective coating to withstand servere weather condition in the earth pit of the standard size comprising of 40 mmx 3m long copper rod as primary conductor and hollow copper tube of 80 mmx 3 m long as secondary conductor to install with suitable connecting terminal cofirming of IS 3043 1987 specification highly conductive packing material to be filled in earth pits for providing uniform low resisitivity anticorrosive ,hygroscope medium around the earth system for improving the efficiency of current dissipation with cystalline conductive mixture CCM 20 kg per bag sufficient quantities required at site complete RCC earthing pit cover material and labour complete all as specified and directed by Engineer-in-Charge. Note :- 1. Excavation / drilling hole in hard soil/rock is included in the rate quoted incld. T&P 2. Min. resistance for earthing pit shall be less than 1 ohm. 3. Drilling or earth work shall be included in the overall cost quoted by the contractor.
M&L for Copper strip 20 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed by Engineer-in-Charge.
M&L GI tubes 40 mm dia. 'medium grad', galvanised, with all fitting; laid in trenches complete all as specified and directed by Engineer-in-Charge.
M&L GI tubes 25 mm dia. 'medium grad', galvanised, with all fitting; laid in trenches complete all as specified and directed by Engineer-in-Charge.
S & F test point terminal block made of gunmetal or phosphorus bronze size 75x75x25mm drilled and screwed incl 3 Nos 8mm dia 25mm long hexa head screw complete all as specified and directed by Engineer-in-Charge.
Taking down carefully copper/aluminium point wiring (light, fan, socket, bell or power) complete including all electrical fittings & fixtures(DBs, submain,cables etc) and making good disturbed surfaces of wall , floor etc and matching wth original colour of wall, complete all as specified and directed by Engineer-in-Charge.
M&L for one light/fan/exhaust fan point wiring controlled by one switch with PVC insulated unsheathed multi stranded copper conductor (FRLS) of size 1.5 Sqmm (for Phase colour code Red and for Neutral colour code Black) and one run of size 1.5 Sqmm PVC insulated unsheathed multi stranded copper conductor (FRLS) (as earth wire, colour code green) and connected to common earth dolly all as specified. , drawn through in and including concealed PVC Conduit medium grade, ISI marked 20 mm dia along with conduit fixing accessories and with pressed steel terminal box thickness 1.6 mm painted with one coat of black bituminous paint as a primary and two coats of enamel paint with 3 mm thick laminated sheet (Make: Hylam) for provision of switches/regulators as per specified SSR and as directed by Engineer- in- Charge. NOTE:-After rewiring cutting chasing portion should be matched with existing finishes of walls.
All as per item No 124 above but 5 Amp socket outlet, independent complete all as specified and directed by Engineer-in-Charge.
All as per item No 124 above but on the same board complete all as specified and directed by Engineer-in-Charge.
All as per item No 124 above but 2.5 sq mm wire for one 15 Amps socket outlet independent with continuous PVC insulated single core green colour copper earth wire of size 1.5 sq mm connected to common earth dolly complete all as specified and directed by Engineer-in-Charge.
Supply and fix switch piano, flush type single pole, one way, 5 Amps, 240 volts complete all as specified and directed by Engineer-in-Charge.
Supply and fix switch piano, flush type single pole, one way, 15 Amps, 240 volts complete all as specified and directed by Engineer-in-Charge.
Supply and fixing socket outlet 2 in 1, 3 pin 5 Amps complete all as specified and directed by Engineer-in-Charge.
Supply and fixing socket outlet 3 pin , 3 pin 15 Amps flush type complete all as specified and directed by Engineer-in-Charge.
Supply and fix ceiling roses, 3 phase, PVC/Polycarbonate, isolated body complete all as specified and directed by Engineer-in-Charge.
S&F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of LED tube light along with fixture,20W complete with all accessories with twin conductor complete all as specified and directed by Engineer-in-charge.
Supply and fix exhaust fan sweep 300 mm in replacement made up of steel body complete with louvers shutter , voltage 230 V , 50 Hz , 1200 RPM copper wound complete all as specified and directed by Engineer-in-charge .
Supply and fix exhaust fan sweep 380 mm in replacement made up of steel body complete with louvers shutter , voltage 230 V , 50 Hz , 1200 RPM copper wound complete all as specified and directed by Engineer-in-Charge.
M&L submain wiring with 2 runs of copper conductor PVC insulated unsheathed cable 1100 volt grade 4 sqmm drawn through PVC conduit medium grade ISI marked 25mm dia as per IS specification fixed concealed in wall/ceiling including conduit and conduit accessories and incl provn of PVC insulated 2 Sqmm multistranded copper conductor as earth continuity conductor connected to earth dolly all as specified including dismantling old and making good to the disturbed surface by plastering and two coat of distamper complete all as specified and directed by Engineer-in-Charge. Note : Two runs of 4 sqmm cable alongwith one run of 2 Sqmm PVC insulated unsheathed copper conductor as earth wire, conduit and conduit accessories will be measured as one length).
M&L for earthing with galvanised steel plate electrode 60cmx60cmx6mm thick buried directly in ground (Earth pit not less than 2.25mtr deep from ground level) surrounded from all directions with charcoal dust, salt and edge of earth plate not less than 1.5 mtr below ground level connected to galvanised iron strip 4mm dia. earth lead by means of nuts, bolts and washers incl excavation and earth work PCC chamber and RCC cover of 1:2:4 type B-1 using XPM weighing not less than 4 Kg/Sqmm using 20mm graded stone aggregate for coping/under covers, 20mm size GI pipe light grade for watering funnel wire mesh etc, complete all as specified and directed by Engineer-in-Charge and shown in electrical plate No-03 of SSR Part-I.
M & L in replacement earthing with steel earth plate electrode of size 60 x 60 cm x 6 mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less tha 1.5 mtr deep below normal grund level connected to galvanized iron strip size 32 x 6 mm as earthing lead by means of nuts, bolts and washers of steel after wlding of GIstrip to earth electrode to the full length of earht plate, 40mm dia GI tubing lightgrade protection pipe upto test point, 20mm dia GI watering pipe with funnel and wire mesh, PCC pit 1:3:6 with pit cover ofsize 30x30 cm made of RCC 1:3: with suitable handle, angle iron frame made of angle iron of size 40x40x4m, adequate qty of charcoal dust and salt layers all around the earth plate and filling of vegetables soil to the remaining 10% removal of surplus soil and retruning filling in all as required at site including test point made outof steel plate of size 75x75x6mm fixed to wall all as specified in plate No 3 of SSR Part-I and complete all as specified and directed by Engineer-in-Charge.
S&F in replacement street light GI pipe bracket 50 mm dia 1.50metre length (ISI marked) light grade bend to shape with two Nos MS clamp duly painted nuts and bolts etc complete all as specified and directed by Engineer-in-Charge.
S&F in replacement LED Street light fitting 45 W pressure die cast aluminium housing with lens and toughened glass top maintanable type , IP66 on building as secutiy light fitting ,the light fitting shall be fixed complete with all the connections complete all as specified and directed by Engineer-in-Charge.
S/Fix in replacement MCB DB SPN 8 Way factory made IP 42 protection class metal double door with 200 Amp rating bus bar 240 for fixing of MCBs/Isolators/RCCBs etc complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of MCB SP 6 to 32 amps 230 Volt complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of MCB SPN 32 Amps 230 Volts complete all as specified and directed by Engineer-in-Charge.
S&F Flame proof weather proof LED Tube light fitting suitable for 1 x 18 Watt (4 feet) with borosil make glass & connector suitable for 1 x 18 Watt LED tube light, including all accessories complete all as specified and directed by Engineer-in-Charge.
S & F switch flame proof rotary type with termination box in LM6 16 A single pole 250V complete all as specified and directed by Engineer-in-Charge.
Concealed point wiring using approved colour codeing as per IS with halogen free flame retardent (HFFR) smoke free non toxic,non corrosive with copper cable 1.5 sqmm confirming to IS : 694 nominal area single core insulated and unsheathed stranded cable 1100 volt grade and including ERW stove enameled concealed conduit heavy duty ISI marked and unsheated copper conductor 1.5 sqmm area as earth wire as earth continuity conductor complete all as specified and directed by Engineer-in-Charge.
Concealed point wiring using approved colour codeing as per IS with halogen free flame retardent (HFFR) smoke free non toxic,non corrosive with copper cable 1.5 sqmm confirming to IS : 694 nominal area single core insulated and unsheathed stranded cable 1100 volt grade and including ERW stove enameled concealed conduit heavy duty ISI marked and unsheated copper conductor 1.5 sqmm area as earth wire as earth continuity conductor for independent 5 Amps socket complete all as specified and directed by Engineer-in-Charge.
M & L flame proof weather proof switch socket & plug combined 16 A 250V (2P + earth) complete all as specified and directed by Engineer-in-Charge.
M & L flame proof weather proof switch socket & plug combined 25 A 500V (3P + earth) complete all as specified and directed by Engineer-in-Charge.
Supply and fix Flame proof Exhaust fan single phase of size (18") with louvers 230 volts single phase AC supply complete with ,bolt,nuts,and washers,suitably embeded in the wall including making suitable opening and provisioning of flexible cord copper of size 23/0.0076 from ceiling rose to exhaust fan for giving connection complete all as specified and directed Engineer-in-charge. All type of wiring should be in steel counduits
Supply and fix XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 35 sq. mm 3.5 core complete all as specified and directed by Engineer-in-Charge.
M&L submain wiring with 2 runs of copper conductor PVC insulated unsheathed cable 1100 volt grade 4 sqmm drawn through PVC conduit medium grade ISI marked 25mm dia as per IS specification fixed concealed in wall/ceiling including conduit and conduit accessories and incl provn of PVC insulated 2 Sqmm multistranded copper conductor as earth continuity conductor connected to earth dolly all as specified including dismantling old and making good to the disturbed surface by plastering and two coat of distamper complete all as specified and directed by Engineer-in-Charge. Note : Two runs of 4 sqmm cable alongwith one run of 2 Sqmm PVC insulated unsheathed copper conductor as earth wire, conduit and conduit accessories will be measured as one length)
S&Fix in replacement MCB DB TPN 4 Way factory made IP 42 protection class metal double door with 200 Amp rating bus bar with incomer as 4 pole MCCB 240/430V for fixing of MCBs/Isolators/RCCBs etc complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of MCB SP 6 to 32 amps 230 Volt complete all as specified and directed by Engineer-in-Charge..
Supply and install in replacement MCCB 4P fixed type 125 Amps rated with breaking capacity 16 KA complete all as specified and directed by Engineer-in-Charge.
SAGAR ENTERPRISES
M/S GEETANJALI ENTERPRISES
M/S Yamin
NAVYUG VYAPARI
Maninder Singh Lohia
36SHRI RADHEY ASSOCIATES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .