Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.3 LAccepted-AOC GATE NO 454 01 TAPKIR NAGAR PUNE NASIK HIGHWAY NEAR GANDHARV NAGARI MOSHI PUNE 412 105 | PUNE | MAHARASHTRA | 412105 | L1 | Accepted-AOC ACCEPTED BEING LOWEST BIDDER | |
| 2 | L2₹53.0 L+₹3.6 L (7.31%)Rejected-Finance | L2 | Rejected-Finance REJECTED BEING NOT LOWEST BIDDER | |
| 3 | L3₹54.3 L+₹4.9 L (9.88%)Rejected-Finance 11 GURU NANAK MARKET AMBALA ROAD SAHARANPUR 247001 | SAHARANPUR | UTTAR PRADESH | 247001 | L3 | Rejected-Finance REJECTED BEING NOT LOWEST BIDDER | |
| 4 | L4₹54.9 L+₹5.5 L (11.1%)Rejected-Finance | L4 | Rejected-Finance REJECTED BEING NOT LOWEST BIDDER | |
| 5 | L5₹57.7 L+₹8.3 L (16.9%)Rejected-Finance | L5 | Rejected-Finance REJECTED BEING NOT LOWEST BIDDER |
| Sl No | Description | Qty | Unit | KSP ENTERPRISES L5 | Maruti Abhiyantriki L6 | MANGAL ELECTRICAL STORES L2 | Rajan Traders L3 | M/S. Niksun Electro-Infra Private Limited L8 | ONKAR ELECTRIC AND GENERAL STORE L1 | SETHI BROTHERS L7 | M/S J P ENTERPRISES L4 | BSK Construction L9 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exc 1.5m wide and not exc 1.5m in depth for laying of cables, pole, stays foundation and getting out in soft loose soil all as specified and directed by Engr-in-Charge | 520 | Cum | 270 ₹1,40,400 | 155 ₹80,600 | 200 ₹1,04,000 | 150 ₹78,000 Lowest | 300 ₹1,56,000 | 220 ₹1,14,400 | 225 ₹1,17,000 | 250 ₹1,30,000 | 350 ₹1,82,000 |
| 2.00 | Excavation in trenches not exc 1.5m wide and not exc 1.5m in depth for laying of cables, pole, stays, foundation and getting out in soft disintegrated rock all as specified and directed by Engr-in-Charge. | 175 | Cum | 450 ₹78,750 | 225 ₹39,375 Lowest | 250 ₹43,750 | 230 ₹40,250 | 650 ₹1,13,750 | 240 ₹42,000 | 225 ₹39,375 Lowest | 450 ₹78,750 | 350 ₹61,250 |
| 3.00 | Excavation in trenches not exceeding 1.5 m width and not exc 3m in depth getting out in soft disintegrated rock all as specified and directed by Engr-in-Charge. | 57 | CUM | 450 ₹25,650 | 180 ₹10,260 Lowest | 300 ₹17,100 | 300 ₹17,100 | 950 ₹54,150 | 230 ₹13,110 | 225 ₹12,825 | 500 ₹28,500 | 400 ₹22,800 |
| 4.00 | Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick all as specified and directed by Engr-in-Charge. | 428 | Cum | 63 ₹26,964 | 30 ₹12,840 Lowest | 30 ₹12,840 Lowest | 77 ₹32,956 | 90 ₹38,520 | 110 ₹47,080 | 50 ₹21,400 | 50 ₹21,400 | 135 ₹57,780 |
| 5.00 | Removal of excavated material of soil not exc 50m and depositing where directed at a level not exc 1.5m above the starting point all as specified and directed by Engr-in-Charge. | 275 | Cum | 63 ₹17,325 | 30 ₹8,250 Lowest | 30 ₹8,250 Lowest | 77 ₹21,175 | 90 ₹24,750 | 105 ₹28,875 | 50 ₹13,750 | 50 ₹13,750 | 250 ₹68,750 |
| 6.00 | M&L PCC (1:3:6) type C-2 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete for foundation of Pole, transformer, Panel board, stay, post top lantern, repairs to road cutting, drain, path all as specified and directed by Engr-in-Charge. | 40 | Cum | 2,700 ₹1,08,000 Lowest | 4,200 ₹1,68,000 | 3,000 ₹1,20,000 | 4,500 ₹1,80,000 | 6,000 ₹2,40,000 | 3,800 ₹1,52,000 | 3,500 ₹1,40,000 | 3,800 ₹1,52,000 | 5,000 ₹2,00,000 |
| 7.00 | M&L PCC (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in coping of new pole / reconstruction of old damaged copings etc, including necessary form work all as specified and directed by Engr-in-Charge | 4.5 | Cum | 5,400 ₹24,300 | 4,500 ₹20,250 | 3,000 ₹13,500 Lowest | 5,000 ₹22,500 | 7,500 ₹33,750 | 4,800 ₹21,600 | 6,000 ₹27,000 | 4,500 ₹20,250 | 5,000 ₹22,500 |
| 8.00 | M&L for road cutting upto 300mm deep and 200mm wide for crossing GI water pipe line through road including making good the disturbed surface by filling mass concrete complete all as specified and directed by Engr-in-Charge.
Note: Mass concrete will be measured and paid as seperate item. | 24 | RM | 360 ₹8,640 | 250 ₹6,000 | 200 ₹4,800 | 300 ₹7,200 | 300 ₹7,200 | 180 ₹4,320 Lowest | 800 ₹19,200 | 200 ₹4,800 | 500 ₹12,000 |
| 9.00 | M&L for sand cushioning in trenches for cable protection all as directed and specified. | 200 | Cum | 900 ₹1,80,000 | 1,200 ₹2,40,000 | 900 ₹1,80,000 | 900 ₹1,80,000 | 1,250 ₹2,50,000 | 800 ₹1,60,000 Lowest | 1,500 ₹3,00,000 | 800 ₹1,60,000 Lowest | 1,500 ₹3,00,000 |
| 10.00 | Supply and lay PCC cable cover class LV type I flat size 250mm x150mmx40mm all as directed and specified | 14,096 | NOS | 24.3 ₹3,42,532.8 | 40 ₹5,63,840 | 18 ₹2,53,728 Lowest | 18 ₹2,53,728 Lowest | 24 ₹3,38,304 | 24 ₹3,38,304 | 41 ₹5,77,936 | 22 ₹3,10,112 | 40 ₹5,63,840 |
Tender Value
₹72.8 L
EMD Value
₹1.3 L
Closing Date
6 May 2026, 6:00 pmClosed
CWE Khadki Pune
Headquarters CWE Khadki, Military Engineer Services, Range Hills Road, Khadki, Pune-411003
PROVISION OF ELECTRIC SUPPLY SECURITY LIGHTS AND HIGH MAST LIGHTS FOR AGNIVEERS AT TRG AREA DIGHI CAMP TRG BN2 BEG AND CENTRE KHADKI UNDER GE CENTRE KHADKI
2026_MES_761182_1
CWE/KKE/TOKEN-19 OF 2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
CWE Khadki Pune
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
Yes
GE Central Khadki
₹1.3 L
Yes
15 Jul 2026
21 Apr 2026
9 May 2026
21 Apr 2026
6 May 2026
28 Apr 2026
21 Apr 2026 - 25 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| - | Excavation in trenches not exc 1.5m wide and not exc 1.5m in depth for laying of cables, pole, stays foundation and getting out in soft loose soil all as specified and directed by Engr-in-Charge | - | Cum | - | - |
| - | Excavation in trenches not exc 1.5m wide and not exc 1.5m in depth for laying of cables, pole, stays, foundation and getting out in soft disintegrated rock all as specified and directed by Engr-in-Charge. | - | Cum | - | - |
| - | Excavation in trenches not exceeding 1.5 m width and not exc 3m in depth getting out in soft disintegrated rock all as specified and directed by Engr-in-Charge. | - | CUM | - | - |
| - | Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick all as specified and directed by Engr-in-Charge. | - | Cum | - | - |
| - | Removal of excavated material of soil not exc 50m and depositing where directed at a level not exc 1.5m above the starting point all as specified and directed by Engr-in-Charge. | - | Cum | - | - |
| - | M&L PCC (1:3:6) type C-2 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete for foundation of Pole, transformer, Panel board, stay, post top lantern, repairs to road cutting, drain, path all as specified and directed by Engr-in-Charge. | - | Cum | - | - |
| - | M&L PCC (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in coping of new pole / reconstruction of old damaged copings etc, including necessary form work all as specified and directed by Engr-in-Charge | - | Cum | - | - |
| - | M&L for road cutting upto 300mm deep and 200mm wide for crossing GI water pipe line through road including making good the disturbed surface by filling mass concrete complete all as specified and directed by Engr-in-Charge.
Note: Mass concrete will be measured and paid as seperate item. | - | RM | - | - |
| - | M&L for sand cushioning in trenches for cable protection all as directed and specified. | - | Cum | - | - |
| - | Supply and lay PCC cable cover class LV type I flat size 250mm x150mmx40mm all as directed and specified | - | NOS | - | - |
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.38 MB
Tenderdocus.pdf
Tender Documents • 0.92 MB
BOQ_852647.xls
BOQ • 3.46 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .