| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.0 LAccepted-AOC SADASHIV PHUGE NAGAR OPP SANDVIK FACTORY RADHIKA RESIDENCY F WING FLAT NO 7 PHUGEWADI PUNE 411 012 | PUNE | MAHARASHTRA | 411012 | L1 | Accepted-AOC L1 | |
| 2 | L2₹19.2 L+₹65,057.50 (3.50%)Rejected-Finance | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹20.5 L+₹1.9 L (10.3%)Rejected-Finance | L3 | Rejected-Finance Not being lowest | |
| 4 | L4₹21.3 L+₹2.7 L (14.7%)Rejected-Finance 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | L4 | Rejected-Finance Not being lowest | |
| 5 | L5₹21.9 L+₹3.3 L (18.0%)Rejected-Finance | L5 | Rejected-Finance Not being lowest |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
3 Jul 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer (CME) Kirkee
Garrison Engineer (CME) Kirkee, Phugewadi, Dapodi, Pune - 411 012
REPAIR/MAINT OF STREET LIGHTS/SECURITY LIGHT FITTING INCL FLOOD LIGHT AT MD ACCN , CTW, 262 CEDU, FCBRNP AT CME
2021_MES_451617_2
8195
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Garrison Engineer (CME) Kirkee
Class D b(i)
7 documents required · 7 mandatory
₹500
Yes
Garrison Engineer (CME) Kirkee
₹60,000
Yes
9 Nov 2021
25 Jun 2021
5 Jul 2021
25 Jun 2021
3 Jul 2021
27 Jun 2021
26 Jun 2021 - 26 Jun 2021
60 days
Amount
Excavation in trenches n. exc. 1.5m wide and n exc. 1.5m in depth for taking out/laying cables in soft/loose soil all as directed.
Excavation in trenches n. exc. 1.5m wide and n exc. 1.5m in depth for pole foundation/laying cables in Hard/dense soil all as directed.
Excavation in trenches exceeding 1.5m wide and n exc. 3 m in depth for pole foundation/laying cables in Hard/dense soil all as directed.
M & L for bituminous road cutting to a width of 45 cm and depth 50 cm for laying UG cables and making good with cement concrete 1:3:6 type C 1 (using 20 mm graded stone aggregate)
Returning filling in, including, spreading, leveling, watering and well ramming in layers n exc. 25 cm all as directed..
Removing surplus excavated material to a distance n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point all as directed.
Supply , laying and testing cable XLPE insulated screened pvc bedded galvanised steel strip or wire armoured , electric power cables ( heavy duty) with stranded aluminium conductor 1100 volts grade cross sectional area 4 core 16 Sqmm in and including taking out old one all as specified and directed.
All as per item 7 above but of the size 4 core 25 Sqmm
All as per item 7 above but of the size 3.5 core 35 Sqmm
All as per item 7 above but of the size 2 core 10 Sqmm
Supply & Laying of Telerex DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 50 mm and inner dia 38 mm polythylene with smoooth inernal and profiled external surface for non pressue under ground cable incl couplers & bends complete all as specified. Make : REX POLYEXTRUSION LTD or its equivalent as approved
S & fix LT Cable joining kit straight through/end termination heat shrinkabale complete with jointing materials suitable for LT Armoured cable 4 core of size 25 to 50 Sqmm all as directed. Make : Denson/3M/Raychem
Cutting of tree branches of any girth along OH lines & street light pole at a distance not less than 2 meter on either side of the pole cleaning of bushes and shrubes of any type along entire RM of pole. Cleaning /prunning should be carried out as and when required during entire running period of contract or as when directed.
Taking down and refixing after repairs of street light LED fittings/flood light fitting on pole or high mast of any type, size or at any height manually or with the help of hydralic street light repair vehicle including replacement of damaged wire connection from kiosk box to LED fitting/high mast fittings, LED lamp, electronic driver etc. Note :- 1. Contractor is responsible to arrange electronic driver for unsv fitting as per existing make and capacity. 2. Electronic driver will be paid seperately. 3. Ladder alongwith vehicle will be borne by Contractor and same will be included in quoting rate.
Supply and fix 'ICON' electronics LED driver Suitable for LED Street light fitting 120 to150 watt.
Supply and fix 'ICON' electronics LED driver Suitable for LED Street light fitting 90watt.. .
Supply and fix 'ICON' electronics LED driver Suitable for LED Street light fitting 60watt.. .
Supply and fix 'ICON' electronics LED driver Suitable for LED Street light fitting 45watt. .
Dismantling and taking down old unsv street/security lights and Material and labour for new LED street light fittings of 45 watt system wattage and high preesure die cast aluminium housing with sealed toughened glass cover, TOP opening separate driver compartment with frame, IP 66 protection suitable for pole mounting SMD led array with lense, cool white 6500 K, LED efficacy >120 lm/W and system efficacy 90 lm/W , 240 Volts AC, 50 Hz, CRI>70% operating voltage range 160 V-270 V, Power factor> 0.95, working temperature range -20ºC to 60ºC,built in surge protection more than 10kV with facility of power supply shall be removed without removing light fitting from pole incl make proper connection complete including cutting , welding , drilling holes, nut bolts, washer complete all as directed by Engineer-in-charge. cat part No ENDURAPEARLNEOSL45WLED757SASYTOPC Havells or equivalent Sury/philips. /C & S
Dismantling and taking down old unsv street/security lights and Material and labour for new LED street light fittings of 60 watt system wattage and high preesure die cast aluminium housing with sealed toughened glass cover, TOP opening separate driver compartment with frame, IP 66 protection suitable for pole mounting SMD led array with lense, cool white 6500 K, LED efficacy >120 lm/W and system efficacy 90 lm/W , 240 Volts AC, 50 Hz, CRI>70% operating voltage range 160 V-270 V, Power factor> 0.95, working temperature range -20ºC to 60ºC,built in surge protection more than 10kV with facility of power supply shall be removed without removing light fitting from pole incl make proper connection complete including cutting , welding , drilling holes, nut bolts, washer complete all as directed by Engineer-in-charge. cat part No ENDURAPEARLNEOSL60WLED757PASYTOPC Havells or equivalent Sury/philips/C & S
Dismantling and taking down old unsv street/security lights and Material and labour for new LED street light fittings of 90 watt system wattage and high preesure die cast aluminium housing with sealed toughened glass cover, TOP opening separate driver compartment with frame, IP 66 protection suitable for pole mounting SMD led array with lense, cool white 6500 K, LED efficacy >120 lm/W and system efficacy 90 lm/W , 240 Volts AC, 50 Hz, CRI>70% operating voltage range 160 V-270 V, Power factor> 0.95, working temperature range -20ºC to 60ºC,built in surge protection more than 10kV with facility of power supply shall be removed without removing light fitting from pole incl make proper connection complete including cutting , welding , drilling holes, nut bolts, washer complete all as directed by Engineer-in-charge. ENDURAPEARLPLUSSL90WLED757SASYTOPC Havells or equivalent Sury/philips/C &S.
Dismantling and taking down old unsv street/security lights and Material and labour for new LED street light fittings of 120 watt system wattage and high preesure die cast aluminium housing with sealed toughened glass cover, TOP opening separate driver compartment with frame, IP 66 protection suitable for pole mounting SMD led array with lense, cool white 6500 K, LED efficacy >120 lm/W and system efficacy 90 lm/W , 240 Volts AC, 50 Hz, CRI>70% operating voltage range 160 V-270 V, Power factor> 0.95, working temperature range -20ºC to 60ºC,built in surge protection more than 10kV with facility of power supply shall be removed without removing light fitting from pole incl make proper connection complete including cutting , welding , drilling holes, nut bolts, washer complete all as directed by Engineer-in-charge. Make : ENDURAPEARLMAGSL120WLED757PASYTOTGASTHO Havells or equivalent Sury/ philips/C &S.
Dismantling and taking down old unsv street/security lights and Material and labour for new LED flood light fittings of 120 watt system wattage and high preesure die cast aluminium housing with sealed toughened glass cover, TOP opening separate driver compartment with frame, IP 66 protection suitable for pole mounting SMD led array with lense, cool white 6500 K, LED efficacy >120 lm/W and system efficacy 90 lm/W , 240 Volts AC, 50 Hz, CRI>70% operating voltage range 160 V-270 V, Power factor> 0.95, working temperature range -20ºC to 60ºC,built in surge protection more than 10kV with facility of power supply shall be removed without removing light fitting from pole incl make proper connection complete including cutting , welding , drilling holes, nut bolts, washer complete all as directed by Engineer-in-charge. JETAIRISFLS 120WLED757APNBLT G Havells or equivalent Sury/philips/C &S.
Dismantling and taking down old unsv floor lightss and Material and labour for new LED flood light fittings of 60 watt system wattage and high preesure die cast aluminium housing with sealed toughened glass cover, TOP opening separate driver compartment with frame, IP 66 protection suitable for pole mounting SMD led array with lense, cool white 6500 K, LED efficacy >120 lm/W and system efficacy 90 lm/W , 240 Volts AC, 50 Hz, CRI>70% operating voltage range 160 V-270 V, Power factor> 0.95, working temperature range -20ºC to 60ºC,built in surge protection more than 10kV with facility of power supply shall be removed without removing light fitting from pole incl make proper connection complete including cutting , welding , drilling holes, nut bolts, washer complete all as directed by Engineer-in-charge. JETA QUANTOPLUSFLP60WLED757SYMLENS Havells or equivalent Sury/philips/C &S.
Supply and fixing or passing through pipe, 1100 volts grade heavy duty , PVC insulated round 3 core 2.5 sqmm copper cable including electrical connection complete all as specified and directed by Engr-in-Charge. Make:-Havells/finolux/Plaza Note:
Taking down UNSV Street light bracket and M & L for fixing new street light bracket made out of GI pipe medium grade 32 mm bore approx length not less than 120 cm bent to shape including new clamps made of MS flat of size 40x5 mm thick including cutting ,welding ,drilling holes ,nut,bolts washers etc including two coat of aluminium paint over one coat of red oxide primer on MS work complete all as specified and as directed.
Taking down UNSV fabrication box and M & L for fabrication of Kiosk box made out of fibre material complete with TPN ,aluminium bus and suitable for one number MCB (SP) including one No MCB (SP) 6 Amps 240 volts with glands for incoming & out going cable including fixing of flat iron clamps of size 20x4mm on PCC/Steel tubular pole complete all as specified and as directed by Engr-in-Charge. Make: Havells/Sintex.
Taking down UNSV fabrication box and M & L for fabrication of Kiosk box made out of fibre material complete with SPN ,aluminium bus and suitable for one number MCB (SP) including one No MCB (SP) 6 Amps 240 volts with glands for incoming & out going cable including fixing of flat iron clamps of size 20x4mm on PCC/Steel tubular pole complete all as specified and as directed by Engr-in-Charge. Make: Havells/Sintex.
Material and labour for replacement of old broken ACSR with aluminium conductor steel reinforced streching without kinks / bends and binding with insulators on street poles complete all as specified and directed by Engineer-in-Charge.
Material & labour for replacement of old cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed inclusive of one primer coat, one under and one finishing coat of aluminium paint all as specified including taking down the old one
M&L for replacement of GI Pipe Light grade with all connected accessories of sizes 40 mm complete as directed.Note:- Clamps nut bolts saddle etc will be paid & measured seperately.
Dismantling and removing and setting aside with CME areas PCC poles any type/size by breaking PCC foundation after disconnecting electrical connection incl site clearance complete all as specified and directed by Engr-in- Charge.
Dismantling and removing and setting aside old unsv steel tubular pole any type/size by breaking PCC foundation after disconnecting electrical connection incl site clearance and depositing to AGE E/M store yard complete all as specified and directed by Engr-in- Charge.
M&L for steel swaged poles complete with cast iron base plate, finial taperplug, bolts, nuts and screws as specified type 410 SP-31, 9 mtr long and including painting with two coats of synthetic enamel aluminum paint over a coat of primer including preparation of new surfaces all as specified .
M&L for providing plain cement concrete type D-2 , 1:4:8 (using 40mm graded aggregate) in foundation filling and mass concrete all as directed.
M&L for providing plain cement concrete type C-2, 1:3:6 (using 40 mm grade aggregate) as in coping, finished even and fair, including necessary from work all as directed at site.
Material & Labour for surface cleaning of steel tubular poles including removing rusted particles and painting with two coats of synthetic enamel aluminium paint over a coat of red oxide including cross arms, bracing, supports, clamps, eye hooks, security light bracket, clamp etc incl repairing and painting on coping with cement base white paint complete all as directed. Note: (i) The quoted rate shall includes marking of numbers on each pole as per direction of Engr-in-Charge. (ii) The quoted rates shall including the reapiring of coping with cement / PCC.
Material & Labour for cement based paint for PCC pole including painting with two coats of synthetic enamel aluminium paint over a coat of red oxide tocross arms, bracing, supports, clamps, eye hooks, security light bracket, clamp etc incl repairing and painting on coping with cement base white paint complete all as directed. Note: (i) The quoted rate shall includes marking of numbers on each LT pole as per direction of Engr-in-Charge. (ii) The quoted rates shall including the reapiring of coping with cement / PCC.
Material & Labour for replacement of old UNSV MCCB of any type/capacity with new MCCB FP 32 Amps 415 AC, 50 Hz, 25kA thermal magnetic release adjustable type complete all as directed. Make : Indoasian cat part No 830267/L&T/Legrand
Material & Labour for replacement of old UNSV MCCB of any type/capacity with new MCCB FP 63 Amps 415 AC, 50 Hz, 25kA thermal magnetic release adjustable type complete all as directed. Indoasian cat part No 830270/L&T/Legrand
Material & Labour for replacement of old UNSV MCCB of any type/capacity with new MCCB FP 100 Amps 415 AC, 50 Hz, 25 kA thermal magnetic release adjustable type complete complete all as directed. Indoasian cat part No 830272/L&T/Legrand
Supply and fixing in replacement three pole Contactor 63 A Current Rating 70A General use 10A, 415V with coil Make L&T Model MNX 70 Three pole contactor complete. Make L&T cat part No CS97076/Legrand/schneider
Supply and fixing in replacement MNX 50 to 80 spare coil for three pole Contactor complete all as specidired and directed. Make : L&T cat part No CS96318/Legrand/scheider
Supply and fixing in replacement Digital timer switch with inbuilt backup current capacity 16 Anps operated on 415 volts AC 50Hz complete all as specified and directed. Make: Indoasian cat part No TDA43111/ Legrand/Indoasian
Taking down old unsv timer switches and S & F of Automatic street light control with infrared sensor based NATRURE SWITCH and VOLTAGE MONITORING SYSTEM (VMS) Three phase load of 8 KW for automation of street lights. Nature Switch operation should be based on Natural light Lux level. Required illuminance level for switching ON is < 30 Lux and for switching OFF > 10 Lux. The sensor should also have part night operation facility of min. 4 hrs. to max. 12 hrs. VMS should have adjustable over & under Voltage trip level and protection against phase loss, Beutral loss & Phase reverse incl Power contactors (3 nos of capacity 25 amps per phase each) and incoming (3 nos of capacity 32 amps each)- outgoing MCB(3 nos of capacity 32 amps each) & main load circuit wiring (Copper) of minimum 10 sqmm. The sensor , VSM, Power contactor, MCBs incl connected items should be enclosed in a Pole/wall mountable enclosure made of rust proof, electric shock proof,termite proof and FR grade SMC junction box conforming to IP54. The circuit should also have provision for manual operation (i.e. sensor & VMS By-Pass option). Model Swadeep- 02EC8kW3P-VMS or equivqlent in Schneider/Havells/Legrand Make (i) Nature switch: Kakatiya Energy Systems/Healer/Bajaj (ii) Power contactor- L&T / BCH / Schneider (iii) Voltage Controlling Device- L&T(GIC) or equivalent (iv) MCB-Hager/schneider/L &T /Legrand, (v) Enclosure & circuit sheet- Sintex (shock proof, rust proof,termite proof,FR rade) (v) Circuit wiring-Polycab/Finolex Note: (i) Nut , bolts, clamp for fixing on Poles/wall are to be included in quoted rates. (ii) The sensor must have the warranty of min of 2 years. (iii) Test certificate and warranty cirtificate must be provided by supplier. (iv) Cost of marking description on the box is incl quoted rates.
Taking down old unsv timer switches and S & F of Automatic street light control with infrared sensor based NATRURE SWITCH and VOLTAGE MONITORING SYSTEM (VMS) Single phase load of 5 KW for automation of street lights. Nature Switch operation should be based on Natural light Lux level. Required illuminance level for switching ON is < 30 Lux and for switching OFF > 10 Lux. The sensor should also have part night operation facility of min. 4 hrs. to max. 12 hrs. VMS should have adjustable over & under Voltage trip level and protection against phase loss, Beutral loss & Phase reverse incl Power contactors (3 nos of capacity 25 amps per phase each) and incoming (3 nos of capacity 32 amps each)- outgoing MCB(3 nos of capacity 32 amps each) & main load circuit wiring (Copper) of minimum 10 sqmm. The sensor , VSM, Power contactor, MCBs incl connected items should be enclosed in a Pole/wall mountable enclosure made of rust proof, electric shock proof,termite proof and FR grade SMC junction box conforming to IP54. The circuit should also have provision for manual operation (i.e. sensor & VMS By-Pass option). Model Swadeep- 02EC5kW1P-VMS or equivqlent in Schneider/Havells/Legrand Make (i) Nature switch: Kakatiya Energy Systems/Healer/Bajaj (ii) Power contactor- L&T / BCH / Schneider (iii) Voltage Controlling Device- L&T(GIC) or equivalent (iv) MCB-Hager/schneider/L &T /Legrand, (v) Enclosure & circuit sheet- Sintex (shock proof, rust proof,termite proof,FR rade) (v) Circuit wiring-Polycab/Finolex Note: (i) Nut , bolts, clamp for fixing on Poles/wall are to be included in quoted rates. (ii) The sensor must have the warranty of min of 2 years. (iii) Test certificate and warranty cirtificate must be provided by supplier. (iv) Cost of marking description on the box is incl quoted rates.
M&L for fault detection in damaged UG cables using cable fault detector/locator, vehicle mounted to accuracy of 2m for various locations inside CME for UG calbes of any size & any type upto 1.1 KV grade including excavation & earthwork in any type of strata of size 4x2x0.6m to visually inspect/repair the damaged cable when and where directed by Engr-in-charge.
M & L for Preparation of old painted surfaces of LT Panel or Street light Panel covered by dust and other deposited materials by cleaning from Panel of Size upto 100 X 100 X 50 cm including Repair of panel door ,hinged nut .bolits clamp . etc .painting with one coat of aluminium paint complete all as specified.
Supply and fix decorative extruded aluminum cylinderical shape LED bollard light 9 watt with integrated driver for soft and comfortable uniform light distribution for garden lighting, path ways and landscaping area lighting complete all as specified and directed. Make : C&S cat part No LTGLCR9WLED/CG/Wipro
Dismantling and taking down old unsv HPSV/HPMV high bay light and material and labour for new LED highbay light of 120 watt powder coated PDC aluminium housing and adustable bracket complete all as specified and directed. Make : C&S Cat part No LTEHB120WHPLED/LS/Havells/Philips
Supply and fixing new generation post top energy saving, environmental friendly, long life aesthetically deigned with symmetrical light distribution spun aluminium landscape luminaire with high power LEDs 25W as light source including taking down old fitting. Make- Havells cat No RUBYPT25WLED757PSYMTOPC or equivalent to Philips/Wipro
Material & labour for earthing complete with galvanized steel earth electrode plate of size 60x60x6mm thick buried directly in ground/earth pit not less than 2.25 mtr deep below normal ground level and top edge of earth electrode not less than 1.5 mtr below normal ground level and connected with GI earth wire of size 4 mm by means of nut, bolts, washers etc to eqpt/machinery all as shown in electric plate No 3 of SSR Pt I including PCC (1:3:6) pit, pit cover 50mm thick RCC 1:2:4 type B-1 using 8mm tor steel bars @10cm C/C both ways, 20 mm bore medium grade GI protection pipe, watering pipe 20mm bore medium grade, funnel, wire mesh, also including earth work, common salt, charcoal dust complete, including taking down old unserviceable earthing all as specified and as directed by Engineer-in-Charge.(Note:-Earth wire/strip to be secured on bus bar insulators and insulators shall be fixed on pole not more than one meter apart with MS clamps made out of 25x4mm MS flat wth nuts, bolts and washers and GI wire/strip shall be fixed in such a way that wire/strip should not be touch on pole in any case)
Taking down and refixing after repairs of street light/high by light HPSV/HPMV/Metal halide fitting of capacity upto 250 watt including replacement of unsv ballast, ignitor, lamp etc all as specified and directed by Engr-n-Charge. Note : Contractor is responsible to arrange ladder of suitable hight for repairing the light.
Sachin Electricals
ganesh electricals and airconditioners
metro electrical services
Pritam Electro Mechanical Services
SKS Electricals
SOURABH ENGINEERS
PURVA ELECTRICALS AND ENGINEERS
Om Construction
Techmat trading solution
Mahindra Electric Stores
M/S. Niksun Electro-Infra Private Limited
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .