Assistant Engineer, P.W.Dte., B.M.C. ESD
Office of Assistant Engineer, P.W.Dte., B.M.C. ESD
SITC of Air-conditioning arrangement incl. allied Electrical Installation work at the department of blood centre under Burdwan Medical College and Hospital, Purba Bardhaman. (Electrical Work).
2026_WBPWD_5014994_1
WBPWD/AE/BMCESD/NIeQ-01/26-27
Open Tender
ELECTRICAL WORKS ORG
15 days
Purba Bardhaman
Please refer Tender documents.
4 documents required · 4 mandatory
₹4,200
4 Jun 2026
4 Jun 2026
22 Jun 2026
4 Jun 2026
19 Jun 2026
4 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1 | Supply, Installation, Testing & Commissioning of Split type AC machines having Cooling Capacity range (7.0 kw - 7.5 kw) with fixed speed rotary compressor, refrigerant gas R410 BEE star rating -3 (EER range 3.5 to 3.99), Air flow range CFM (600-777), Operating Outdoor Temparature = 50ºC and above, Power Supply - 240V, 50Hz [ (+-)Tolerrance as per applicable standard ], both condenser and cooling coils made of copper tube connecting chord with plug top confirming to IS 1391 (Part-I & Part- II) with all amendments. The Machine should be equipped with all the requisite control system for the Total System / Temperute / Air - Distribution/ Electrical Power System and others like Remote Sensing Device etc. (Make- Mitsubishi Heavy Duty ( Model- SRK25CSS-S6, 2Star / O General / Mitsubishi Electric)
Split AC must be following essential requirement.
i) Indoor PCB unit must be within a metal enclosure as per CEWE order.
ii) P2 protected capacitor must be included in each RAC.
iii) Comprehensive Warranty : 1 year & additional 5 years on Compressor. | 1 | Set | - | - | item code1 |
| 2 | Supply, Installation, Testing & Commissioning of split type AC machines having Cooling Capacity range (5.2 kw - 5.3 kw), with fixed speed rotary compressor, refrigerant gas R32/R410 BEE star rating -3 (EER range 3.5 to 3.99), Air flow range CFM (600-777), Operating Outdoor Temparature = 50ºC and above, Power Supply - 240V,50Hz [ (+-)Tolerrance as per applicable standard ] both condenser and cooling coils made of copper tube connecting chord with plug top confirming to IS 1391 (Part-I & Part- II) with all amendments. The Machine should be equipped with all the requisite control system for the Total System / Temperute / Air - Distribution/ Electrical Power System and others like Remote Sensing Device etc (Make- Mitsubishi Heavy Duty ( Model- SRK20CSS-S6, 3 Star / O General / Mitsubishi Elctric)
Split AC must be following essential requirement
i) Indoor PCB unit must be within a metal enclosure as per CEWE order.
ii) P2 protected capacitor must be include each RAC.
iii) Comprehensive Warranty : 1 year & additional 5 years on Compressor. | 1 | Set | - | - | item code2 |
| 3SITC including vaccumiazation and Nitrogen of testing of following HVAC grade nominal size of soft copper refrigerent piping [ Make Royku / Totaline/ Mandeep ] for RAC system, complete with fittings with adjustable ring type hanger supports, jointing/brazing after bending, swerazing, welding complete with fittings, elbows, bends, globe valve of suction & liquid line supporting arrangement on walls including accessories, insulated with XLPE class -O tubular insulation/with Class-O closed cell elastometric nitrile rubber [ Make Supreme/ Aroflex] tubular sleeves sections of specified thickness as given below for suction and liquid lines with supports & brackets as per direction of EIC all accessories according to specification etc. as required. | ||||||
| 3.01 | 5/8" (15.88 mm.) dia (Soft drawn) Cu. Pipes (As per standard BS864 or ANSIB 16.22) with tube thickness 0.6 mm mm incl. 13 mm thick insulation. | 24 | Mtr | - | - | item code4 |
| 3.02 | 1/4" (6.4 mm) dia (Soft drawn) Cu. Pipes(As per standard BS864 or ANSIB 16.22) with tube thickness 0.6 mm incl. 13 mm thick insulation. | 24 | Mtr | - | - | item code5 |
| 4Supply and laying of 1.1 KV single core stranded 'PVC insulated FRLSH grade copper cable incl socketing, shaddling etc.as per direction of EIC ( Make : Finolex/ Havells/ Polycab/ RR Kabel/ Gloster) of requisite following diameter for the above Air-Conditioners as per direction of Engineer - In - Charge incl. necy. fittings as required as per G.S . [Power cable for connection betweeen indoor and outdoor units & also Control Cable for connection betweeen outdoor units to indoor ] | ||||||
| 4.01 | 3 core x 4.0 mm² Round PVC insulated copper cable | 22 | Mtr | - | - | item code7 |
| 4.02 | 4 core x 2.5 mm² Round PVC insulated copper cable | 24 | Mtr | - | - | item code8 |
| 5 | Supply & laying of flexible PVC high quality water carrying pipe of proper size for draining water from already installed AC to any available (nearest) drain water pipe or near to ground level and the pipe must be properly saddled with the wall incl. proper insertion of the flexible pipe to drain water pipe and sealing the entry with required materials like PVC tape, High quality sealing the entry with required materials like PVC tape, high quality sealing gum etc. as reqd. All these arrangement for fixing must be arranged by the agency itself as per direction of EIC. | 30 | Mtr | - | - | item code9 |
| 6 | Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Make:- Legrand/Anchor Roma/Cabtree), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc. [E-17/5(a)] | 2 | Nos | - | - | item code10 |