Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.3 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹41.7 L+₹38,335.20 (0.93%)Rejected-AOC NO 71 1ST CROSS MUNESWARA BLOCK PALACE GUTTAHALLI BANGALORE 560 003 | BENGALURU URBAN | KARNATAKA | 560003 | L2 | Rejected-AOC L2 | |
| 3 | L3₹41.8 L+₹46,223.80 (1.12%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹42.4 L+₹1.0 L (2.51%)Rejected-AOC NO 26 SRI GANESH 7TH CROSS BDS NAGAR DIBBUR RAMAIAH LAYOUT K NARAYANPURA MAIN ROAD BANGALORE 560 077 | BENGALURU URBAN | KARNATAKA | 560077 | L4 | Rejected-AOC L4 | |
| 5 | L5₹44.2 L+₹2.9 L (6.96%)Rejected-AOC | L5 | Rejected-AOC L5 |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
14 Nov 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Yelahanka
GE (AF) Yelahanka Bangalore - 63
PROVISION OF ADDITIONAL ROOMS WITH ATTACHED TOILETS IN SNCO MESS AT AFS YELAHANKA
2022_MES_558269_1
8115/E8
Open Tender
Civil Works
Item Rate
180 days
AF Stataion Yelahanka
As per NIT
9 documents required · 9 mandatory
₹500
GE (AF) Yelahanka
₹92,000
Yes
10 Mar 2023
17 Oct 2022
16 Nov 2022
17 Oct 2022
14 Nov 2022
1 Nov 2022
Amount
Surface dressing n.exc 15 CM deep and getting out in soft loose soil .
Excavation in trenchs not exceding 1.5 m wide & depth for foundation etc or for shaft,wells, etc and n. exc 10 Sqm on plan and n.exc M in depth & getting out in soft/loose Soil.
All as item No 2 above but each additional 1.5mtr or part thereof in depth beyend 1.5mtr and getteing out in soft / loose soil complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for fdn for shafts, cills, cesspits, manholes pier holes n.exc 10 Sqm on plan and getting out complete in any type of soil complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of cables, pipes, foundation for poles etc, and getting out in hard/dense soil.
Returning filling in , including spreading , levelling, watering and well ramming in layers not exceeding 25 CM.
Removing of excavated surplus soil not exceeding 50m and depositing where as directed at a level not exceeding 1.5m above the staring point.
M&L for PCC type D-2,1:4:8 with using 40mm graded stone aggregate in foundation, filling & mass concrete.
M/L for precast cenment concrete type B1 1:2:4 (20 mm graded agg) block masonary with solid blocks exc 10cm in width and setting in CM 1:6
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing .
Ditto all as per item ser No 8 as above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter and finished concrete flat.
Formwork to sides of pillars, posts, struts, piers, columns, and stanchions and finished rough surfaces of concrete flat.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc and finished rough surfaces of concrete flat.
M&L Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping)
M&L for Reinforcement cement concrete M-25 Grade with using 20mm graded stone agg in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under reamed piles and mass concrete.
M&L for Reinforcement cement concrete M-25 with using 20mm graded stone agg in Columns, pillars, piers, posts and struts.
M&L for Reinforcement cement concrete M-25 with using 20mm graded stone agg in Beams, cantilevers, bressummers, lintels over 1.5m span.
M&L RCC Slabs supported on walls in M-25 using 20 mm graded agregate, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like
M&L 15mm thick cement plaster in CM 1:4 on brick work or concrete surfaces rendering is to be even & smooth without using extra cement on external wall
M&L for Preparation of the new surfaces of walls plastered , and applying two cots of weather proof paint , complete all as specified and as directed.
M&L 10mm thick cement plaster in CM 1:6 on brick work or concrete surfaces rendering is to be even & smooth without using extra cement on internal walls
M&L for Preparing the new surfaces of wall and applying two coat of oil bond distemper over a coat of interior wall care putty all as specified and as directed
M&L 5 mm thick rendering or concrete surfaces in cement mortar (1:3) all as specified and directed.
M&L Two coat of white washing on New decorated ceiling surfaces incl preparation of surfaces.
M&L for hard core of guage 63mm deposited, spread and levelled to a true surface.complete all as specified and directed.
M&L Cement concrete 1:4:8, 75 mm thick, type D2 using 40 mm graded stone aggregate as sub base of floor .
M&L 75 mm thick cement concrete type B-2,1:2:4(40 mm graded stone aggregate) for plinth protection .
S&F powder coated anodised aluminium frame and shutters with all fixing arrangements for doors, windows and ventilators with one or more rebates including joing cleat for fixing etc aluminium section of powder coating not less than 50 micron all as specified and directed.
S&F powder coated aluminium door/Windows/ventiliator shutters aluminium section weighing 0.55kg/m including necessary joining, fixed type, cleats, glazing clips, rubber neoprene packing, roller in each window, anodised alumnium snap beading, screw etc, complete all as spd.
S&F II nd class hard wood Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed all as specified and directed.
S&F Mild steel flat as in hold fast , wall ties plain angle clean for securing purline to wood trusses and wiremesh conforming to Fe 290 Gde E-165.
S& F flush door 30mm thick membrane doors decorative finish on one side duly finished and polished and other side all as per manufacturers directions as per tint / colour including necessary teak wood lippings of necessary all as directed by Engr - In Charge. (Note; manufacture MAXON,)
S&F 35mm thick 2 nd class Hard wood Glazed and Skelton shutters, open rebated and prepared to receive glass, gauze etc divided into squares,with plain,chamfered or rounded,mitred and rebated sash bars,any numbers.edges of framing plain, chamfered or rounded, fitted with cut and mitered beads for securing glass etc, sizes of members of shutters as specified in SSR Part-I, Section 8, clause 8.24 and fitted to chowkats.
M&L preparing new or previously untreated wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer.
M&L Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in single side prelam PVC sheet used instead of Plain colour PVC sheet & edges will be painted to match with prelam sheet all as specified and directed.
M&L Factory Made Solid PVC Moulded Door Shutter, with particle board core 28 to 30 mm thick (stiles),with 2, 4, or 6 raised panel design with 2mm thick Moulded Prelam PVC Sheet on the front face & 2mm Plain colour PVC Sheet on back face including neccessary fitiings etc complete as specified and directed.
S&F Butt hinges of size 100mm extruded aluminium alloy with galvanised mild steel hinge pin,anodised and fixed, type C-21 all as specified and directed.
S&F aluminium alloy anodised, sliding door bolt 250 mm long with hasp, staple (bolt type) and fixing clips of sheets , cast or extracted section and fixing bolt and sliding bolts of extracted section.
S&F for aluminium anodised, barrel tower bolt 150mm of extruded section.
S&F for aluminium handle 150mm cast type anodised.
S&F sheet glass ordinary quality 5mm thick as in doors,window, showcase alum frame work & similar work with or without glass roller any size including neoprime gasket all as directed by Engineer-in-Charge
All as item 42 above but 4 mm thick figured glass pin head type
S & F stainless steel wire cloth 0.36 mm nominal dia of wire and average width or aperture 1.40 mm all as specified and directed. Note : Rate quoted by the contractor is inclusive of rate for fixing of wire cloth in steel& wooden windows/ventilators with MS flat from 15 x 3mm and fixing of wire cloth in wooden shutters with 2nd class hard wood beading all as specified and directed .
S & F framed work as grills conforming to Fe 290 Gde E-165
M&L Glazed coloued Ceramic tiles of size 450X350X7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match as in skirting/dado over 10 mm thick screed bed in CM 1:4 finished all as specified and directed in toilets ang kitchen.
M & L Non skid coloured ceramic tiles 7 to 8 mm thick matt finish(square/ rectangular) area of ech tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match with tile incl screedd bed 15 mm thick in CM (1:6) complete all as directed and specified.
M&L Non skid coloured Ceramic tiles 7 to 8 mm thick and area of each tiles not exceeding 0.18 Sqm as in flooring over 15mm thick screed bed in CM 1:6 all as specified and directed.
M&L Non skid coloured Ceramic tiles 7 to 8 mm thick and area of each tiles not exceeding 0.18 Sqm as in skirting/dado over 10 mm thick screed bed in CM 1:4 finished all as specified and directed
S&F vitreous china wash down water closet pan (pedestal pattern), white premium quality (excluding fixing bolts, flushing cistern and flush pipe) all as specified and directed.
S&F plastic pedestal pattern seat cover with flat bottom and cover and MS chormium plated hanging type device all as specified and directed.
S&F10 litre capacity PVC syphonic action type for low level flushing cistern including all fittings and including flushing pipe fixed in repair all as specified and as directed.
S&F CP Towel rail of including fiitings of neccessary screws etc complete all as specified and directed by the Engr-in-Charge.Make - Jaguar (Code-AKP-35711PS). or Equivalent
S&F CP health fauccet of including neccessary holding arrangements with screws etc all as specified and directed by the Engineer -in -charge.Make - Jaguar (Code-ALD-577) or Equivalent
S&F 15 mm dia bib cock wall flange (fancy type), cast copper alloy with with screwed down, screwed for iron pipe or for brass ferrule complete with check nut 15mm bore complete all as specified and directed by Engr-in-Charge.. Make - Jaguar (Code-VGP - 81037) or Equivalant
S&F Angle cock with wall flange 15 mm dia Fancy type Make - Jaguar, Cat Part No - VGP-81053 or Equivalent
S&F Soap Dish all as specied and directed by Engr-in-Charge. Make : Jaguar (Code No ACN-1131N) or Equivalent
S&F Paper holder with Flap Recessed Type (Stainless steel), , all as spd and directed by Engr-in-Charge. Make : Jaguar (Code No AQN-7753) or Equivalent as approved by GE.
S&F CPVC pipes 20 mm SDR 11 & Plain VPVC SDR 11 on walls, ceiling orf laying including fitting in floors all as specified and as directed by Engr in Charge.
S&F CPVC pipes 25 mm SDR 11 & Plain VPVC SDR 11 on walls, ceiling orf laying including fitting in floors all as specified and as directed by Engr in Charge.
S&Fs PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall (110 mm bore) including flat iron claim for proper fixing complete all as specified & directed by Engr-in-charge.
S&F PVC(SWR) bends 110mm dia complete all as specified & directed by Engr-in-Charge.
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall (75 mm bore) including flat iron claim for proper fixing complete all as specified & directed by Engr-in-charge.
S&F PVC(SWR) bends 75mm dia complete all as specified & directed by Engr-in-Charge.
S&F High density polyethylene pipes 50 mm bore of pressure ratings 6 kgf/cm2 fixed complete to walls,floors,ceiling etc. Including necessory fittings.
M&L for 75mm dia of outlet PVC Nahani trap with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed by Engr-in-Charge.
Material and labour for rendering 15mm thick (average) in cement mortar 1:4 on roof surfaces mixed with water proofing compound as per manufacturer's instructions, finished even and smooth without using extra cement. Note:- supply only of water proofing compound will be measured and paid seperately under relevant item
Supply only approved integral water proofing compound.
M&L Applying oil bounded bitumen primer @ 0.20 Kg/Sqm, and providing 4mm thick APP modified water proofing membrane weighing not less then 4.0 Kg/Sqm, reinforced with non woven polyester matt weighing not less then 160 gm/sqm having softening point not less then 150 degree centigrade, having tensile strength of 650 N/5 cm and 350 N/5cm in longitudinal and transverse directions respectively of the reinforcement, trearing strength of 180 N by torch- on application including min 10cm side over lap & 15 cm end laps. Applying a coat of blown grade hot bitumen 90/15 over the membrane @ 1.2 Kg/sqm as per the detailed specifications. Note : The laying/ applying of APP membrane and other connected work shall be carried out by the approved applicator of the manufacturing company of APP membrane.
S&F rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) hoisted and jointed in position all as specified in SSR Part-I (500 ltr capacity) and providing all necessary fittings for connecting with pipe line, threaded type cover complete all as specified and directed by Engr-in-Charge.
S&F Ball Brass valve 25 mm dia high pressure, with polythene float and flynut complete all as specified and as directed.
S&F Gun-metal, bore globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed 20mm.
All as per item No 71 above but 25mm bore
S& F for aluminium powder coated drapery rod 32mm dia fixed with suitable bracket complete.(Note: Bracket will be measured and paid separately).
S& F aluminium powder coated fancy type suitabe brackets fixed at both ends of openings fixed over 1st class hard wood rounded wooden blocks 0f 65mm dia and 20mm thick fixed to stone wall/Brick wall using screws incl necesary drilling & finished with polishing Each opening shall have two fillets at both ends.
S & F Ready made 9 feet pully operated cloth drying system aluminium anodised 22mm outer dia pipe channel assemlbly locking system to hide rope knot ropes 4mm dia HDPE doub;e core & fitting material etc complete all as specified and directed.
M & L for providing and injecting chemical emultion for post construction antitermite along the external of wall below concret or masonary apron using chemical emultion at the rate of 2.25 litre per linear meter including drilling and pluging holes etc complete all as specified and directed.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 18cm deep and getting out
S & F machine pressed rubber moulded coloured precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 MM thickness , M 35 grade with grey cement and pigment bedded and laid over and including 50 mm thick sand cushion compacted and joint filled as specified and directed
M&L for concrete bed to drain pipes in PCC 1:4:8 type C2 using 40mm graded stone aggregate including packing under and haunching against sides of pipes after they are laid and tested for 150mm dia pipe
M&L for Reinforced concrete pipes, class NP2, 150mm dia laid and jointed complete with collars
M&L PCC 1:2:4 type B1 using 20mm graded stone aggregate as in Coping /benching of manholes including eatherlng,rounded /chemfered angles and throating as directed including necessary form work and finishing all exposed surfaces of concrete even and smooth without using extra cement complete all as specified and as directed.
M&L for Precast RCC cover slabs for manholes 1:2:4,type B1,using 20mm graded stone aggregates,set in CM 1:4 including necessary form work and finishing the exposed surfaces of concrete even and smooth without using extra cement complete all as specified.
S&F Mild Steel TMT bars 6 to 8mm dia, cut to length bent to shape requried including cracking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips all as specified and as directed.
M&L for rendering 15 mm thick in CM 1:6 on fair faces of brick workor concrete surface finished even and smooth without using extra cement complete all as specified and directed.
M & L for Cutting into existing manholes 150mm dia for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required
Point wiring complete with 1.5 sqmm single core PVC insulated heavy duty ISI Marked , unsheathed cable 1100 volts grade with multistranded copper conductor drawn through concealed PVC conduit not less than 20mm dia and including provision of PVC insulated heavy duty copper conductor, 1.5 sqmm for earth continuity conductor and connected to common earth dolly, including suitable size of sheet metal box 1.6mm thick fixed and flushed inside the walls, with 3mm thick laminated sheet top cover for housing the switches, socket outlets, fan regulators Including fixing PVC round block 8 cm dia and 4 cm in depth etc., for the following:-
(a) One light/Exhaust Fan point controlled by one switch.
(b) One ceiling fan controlled by one switch
(c) One socket 5 amp on independent board.
(b) One switch socket outlet point 3 pin 5 Amps on same board with other switches.
(e) One Bell Point controlled by one Bell Push
All as per item No 88.05 above but wiring with 2.5 sq mm copper cable with 2.5 sq mm for one earth continuty cable for 6 pin 15 Amps socket out controlled by 15 Amps switch.
M&L for point wiring complete with 2 run of 4.00 sqmm single core PVC insulated heavy duty ISI Marked, FRLS, unsheathed cable 1100 volts grade with multistranded copper conductor drawn through and including rigid PVC conduit not less than 20mm dia and conduit accessories fixed to walls/roofs/floors/ceiling etc., and including provision of PVC insulated heavy duty ISI Marked unsheathed copper conductor FRLS 4 sqmm for earth continuity conductor and connected to common earth dolly for 20 Amps Metal clad socket.
Supply and fix Modular switch 1 way 6A, 1 module type, 230 volts, ISI marked complete.
Supply and fix Modular Bell push 6A 1 module type, 230 volts, ISI marked complete.
Supply and fix Bell ding dong AC 230 V complete.
S & F Modular type stepped type electronic fan regulator 2 Module 230 Volts
Supply and fix ceiling rose surface bakelite 65x50mm 3 terminals.
Supply and fix Modular Socket, 6A - 2/3 pin combined 2 module, multipurpose flush type, ISI marked complete all as specified and as directed.
Supply and fix Modular Socket 6A/16A - 2/3 pin combined 2 module, multipurpose flush type, ISI marked complete all as specified and as directed.
Supply and fix Modular switch 1 way 16A, 1 module, multipurpose flush type, ISI marked complete all as specified and as directed.
Supply and fix MODULAR WHITE COVER PLATE WITH FRAME White cover plate with frame, 1 module ISI marked complete all as specified and as directed.
Supply and fix MODULAR WHITE COVER PLATE WITH FRAME White cover plate with frame, 2 module ISI marked complete all as specified and as directed.
Supply and fix MODULAR WHITE COVER PLATE WITH FRAME White cover plate with frame, 3 module ISI marked complete all as specified and as directed.
Supply and fix MODULAR WHITE COVER PLATE WITH FRAME White cover plate with frame, 4 module ISI marked complete all as specified and as directed.
Supply and fix MODULAR WHITE COVER PLATE WITH FRAME White cover plate with frame, 6 module ISI marked complete all as specified and as directed.
Supply and fix MODULAR WHITE COVER PLATE WITH FRAME White cover plate with frame, 8 module ISI marked complete all as specified and as directed.
Supply and fix MODULAR METAL FLUSH BOX Metal flush box 1/2 module ISI marked including flushing the Box inside the wall and making good to the disturbed surfaces and also matching with the existing surface all as specified and directed by Engr in charge.
Supply and fix MODULAR METAL FLUSH BOX Metal flush box 3 module ISI marked including flushing the Box inside the wall and making good to the disturbed surfaces and also matching with the existing surface all as specified and directed by Engr in charge.
Supply and fix MODULAR METAL FLUSH BOX Metal flush box 4 module ISI marked including flushing the DBs inside the wall and making good to the disturbed surfaces and also matching with the existing surface all as specified and directed by Engr in charge.
Supply and fix MODULAR METAL FLUSH BOX Metal flush box 6/8 module ISI marked including flushing the DBs inside the wall and making good to the disturbed surfaces and also matching with the existing surface all as specified and directed by Engr in charge.
Supply and fix LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose including dismantling old unsv fittings complete all as specified and directed.
Supply and fix LED light fitting (mirror light) with high out put diffuser, 2 feet long, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size and two round block for mounting tubelight fittings including dismantling old unsv fitting complete all as specified and directed by Engr-in-Charge.
Supply and fix building security light LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP-66 protection complete all as specified and directed by Engr-in-Charge.
Sub main wiring complete with two runs of 10 Sqmm single core PVC insulated heavy duty ISI Marked FRLS, unsheathed cable 1100 volts grade, multistanded with copper conductor drawn through and including 32 mm dia non matallic rigid PVC conduit and conduit accessories must be concealed, and including provision of PVC insulated heavy duty ISI Marked, unsheathed cable 1100 volts grade 10 Sqmm for earth continuity conductor and making good the disturbed surface also matching the existing surface all as specified and as directed by Engineer-in-charge.Note:- Four Run of 6 Sq mm cable and one run of PVC conduit will be measured as one Run or one Meter.
Sub main wiring complete with two runs of 6 Sqmm single core PVC insulated heavy duty ISI Marked FRLS, unsheathed cable 1100 volts grade, multistanded with copper conductor drawn through and including 25 mm dia non matallic rigid PVC conduit and conduit accessories must be concealed, and including provision of PVC insulated heavy duty ISI Marked, unsheathed cable 1100 volts grade 6 Sqmm for earth continuity conductor and making good the disturbed surface also matching the existing surface all as specified and as directed by Engineer-in-charge.Note:- Three Run of 6 Sq mm cable and one run of PVC conduit will be measured as one Run or one Meter.
Supply and fix Sheet metal enclosure double door MCB DB Triple Pole and Neutral 4 way with 200 A rated bus bar 415V & neutral link complete including flushing the DBs inside the wall and making good to the disturbed surfaces and also matching with the existing surface all as specified and directed by Engr in charge.
Supply and fix sheet metal enclosures for MCB distribution board 240 Volts Single pole and neutral 8 way Double door complete including flushing the DBs inside the wall and making good to the disturbed surfaces and also matching with the existing surface all as specified and directed by Engr in charge.
Supply and fix single pole and netural encloser with a two pin and earth plug socket complete with one single pole MCB of 20 Amps.
Supply and fix MCB Triple Pole and Neutral, 240 volts, 63 Amps, 'C' Curve, 10 KA, including disconnecting, taking down old/unserviceable, MCB Single pole and Neutral complete all as specified and as directed by Engr-in-charge.
Supply and fix MCB Single pole and Neutral, 240 volts, 32 Amps, 'C' Curve, 10 KA, including disconnecting, taking down old/unserviceable, MCB Single pole and Neutral complete all as specified and as directed by Engr-in-charge.
Supply and fixing MCB Single pole, 240 volts, 6 to 32 Amps, 'B' Curve, 10 KA, including disconnecting, taking down old/unserviceable, MCB Single pole and Neutral complete all as specified and as directed by Engr-in-charge.
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc all as specified and directed by Engr-in-Charge.
Supply and fix ceiling fans, complete with three blade, down rod, accessories 230V, 1200mm sweep, with Squirrel cage induction motor complete all as specified and directed by Engr-in-charge.
Supply and fix exhaust fan 250mm sweep, made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding complete all as specified and directed by Engr-in-Charge.
M & L for Earthing complete with galvanised earth plate electrode of size 600x600x6mm thick burried directly in ground earth pit not less than 2.25 m below ground level with top edge of earth plate not less than 1.5 mtrs below ground level connected to 4 mm dia GI earth wire as earth lead upto a length of 7.5 metre long by means of bolts,nuts, washers etc. and protected by GI pipe light grade 15mm dia and 20mm dia GI tubing light grade with funnel for watering, all as shown in electrical plate No 3 of SSR Part-I, back-fill with salt and charcoal, provision of test point including connected to earth test point and necessary earth work excavation in any type of soil PCC (1:3:6) type C1 bed and chamber RCC (1:2:4) type B1, iron grill including GI cover with hinge and funnel watering pipe etc all as specified and directed by Engr-in-Charge.
Supplying and laying un-reinforced precast concrete cable cover, class LV, Type 1 with peak, size 250 mm x 150mm x 40mm
Returning filling in excavated soil upto a depth of 30cm after riddling excavated soil (in lieu of sand) for cushioning of cable and refilling of trenches with left over normal excavated soil complete as directed.
Supply and laying in trenches, floors, roof, ducts, LT underground cable of size 4 core 16 Sqmm XLPE insulated armoured and PVC sheathed 1100 Volts grade with aluminium conductor multistranded including cable connecting lugs, glands, jointing materials etc. and fixing using clamps, saddle for pole, wall etc.
Supply and fix GI tubing light grade 40mm bore in trenches /fixing on pole /wall /crossing in drain etc. for protection of UG cable all as specified and directed.
Supply, installation and commmissioning LT out door loop in loop out panel board with sloping canopy of size 600mmx450mmx300mm made out of 3 mm thick CRCA sheet duly painted with two coars of syntehtic enamel paint over a coat of rex oxide, front and rear hinged doors mounted on 40x40x6 mm MS angle iron frame 90 cms height erected in ground with PCC foundation 1:4;8 with 40mm stone aggregate including supply and fixing insulated aluminium bus bar of size 50x 6mm for three phase and neutral 200mm length respectively mounted on insulators and terminating with suitable cable with glands and provision of one MCCB 63 Amps 4 pole, 415 Amps, 50 Hz of breaking capacity 16 KA as incomer including taking down old terminal boxes complete all as specified and directed by Engr-in-Charge.
Lakkaiah Rangaswamy
SRUSHTI CONSTRUCTIONS
SRI GANESH ENTERPRISES
SRI AYYAPPA ENTERPRISES
chowdeshwariconstructionco
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .