Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.4 LAccepted-AOC 1ST FLOOR H NO 165 GALI NO 16 S B S COLONY KARAWAL NAGAR DELHI EAST DELHI DELHI 110094 | NORTH EAST DELHI | DELHI | 110094 | L1 | Accepted-AOC Being the lowest | |
| 2 | L2₹24.1 L+₹2.7 L (12.6%)Rejected-Finance 63 2ND MAIN ROAD NGO COLONY ADAMBAKKAM CHENNAI 600 088 | CHENNAI | CHENNAI | TAMIL NADU | 600088 | L2 | Rejected-Finance Being other than L1 | |
| 3 | L3₹24.5 L+₹3.1 L (14.6%)Rejected-Finance HOUSE NO 41 WARD NO 09 ARYA SAMAJ GALI UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | J K | 182101 | L3 | Rejected-Finance Being other than L1 | |
| 4 | L4₹28.5 L+₹7.1 L (33.3%)Rejected-Finance DOOR NO 2 31 23 SECTOR 7 SBI COLONY MVP VISAKHAPATNAM 530 017 | VISAKHAPATANAM | ANDHRA PRADESH | 530017 | L4 | Rejected-Finance Being other than L1 | |
| 5 | L5₹31.5 L+₹10.1 L (47.4%)Rejected-Finance 1 6 620 CHAITANYAPURI INDRA NAGAR DILSUKHNAGAR HYDERABAD TELANGANA 500060 UDYAM TS 09 0007870 37AAEPO0535A1Z8 B 36AAEPO0535A1ZA R MSME STATUS AS VERIFIED | RANGA REDDY | TELANGANA | 500060 | L5 | Rejected-Finance Being other than L1 |
| Sl No | Description | Qty | Unit | R. S. Associates L1 | M/s SS Engineering Enterprises L4 | M/s Trade Linker Associates L6 | rvelectricals L7 | EVEREST ENGINEERING WORKS L2 | BHARAT ENGINEERS L8 | DPS sales and services india L5 | M/S N K POWER SYSTEMS AND PROJECTS L3 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply, install, testing and commissioning of Retrofit Emission Control Device (RECD) suitable for existing Diesel Generator Set of any make and model of 320 KVA capacity complete all as specified and as directed with following specification:-. | 1 | EACH JOB | 7,99,562.1 ₹7,99,562.1 | 10,50,000 ₹10,50,000 | 12,80,000 ₹12,80,000 | 13,79,420 ₹13,79,420 | 8,05,400 ₹8,05,400 | 15,00,000 ₹15,00,000 | 10,93,263 ₹10,93,263 | 7,37,373.73 ₹7,37,373.73 Lowest |
| 1.01 | (a) Purification Technology :- No filters, No solvents, No Chemicals
(b) Pollution Captured : PM 2.5 to PM 10
(c) Electric Supply : 220 Volts AC
(d) Back Pressure: No advance impact on Engine
(e) Material : Mild Steel
(f) Reported PM Reduction: 80% to 90% (ARAI and other NABL accredited Labs)
(g) By Product : Soot Particles.
(h) Disposal : NO burning or dumping of captured partured particles.
(i) Collection of captured Particles : Once in 02 Months.
(j) Capturing Chamber Material: Stainless Steel. | - | - | - | - | - | - | - | - | - | - |
| 1.02 | (k) Mechanicial Pressure Release valve shoud be available.
(l) Sensors (Temp & Pressure) should be avoidable.
(m) Bypass System Should be available.
NOTE :
(i) RECD should be tested by any of the authorised / recogonised Central Pollution Control Board approved by GE and test certificate should be produced befor installation of RECD in the Generator Set.
(ii) The quoted rate shall be inclusive for the following jobs and no additional / extra Payement shall be allowed
[a] Taking down and removing the existing silencer pipe with connected items and make necessary arrangements as required for fixing / connectiong RECD
[b] Suitable size pipe of required length
[c] Wiring with suitable size Copper cable from DG Control Panel.
[d] Test report shall be submitted after commissioning and testing of emission as per standard instructions and as directed by Engineer-in-Charge.
(iii) The unit rate quoted shall be deemed to include the cost of two years maintenance of RECD from the certified date of completion of work. | - | - | - | - | - | - | - | - | - | - |
| 2.00 | Supply, install, testing and commissioning of Retrofit Emission Control Device (RECD) suitable for existing Diesel Generator Set of any make and model of 625 KVA capacity complete all as specified and as directed with following specification:-. | 1 | EACH JOB | 13,38,474 ₹13,38,474 Lowest | 18,00,000 ₹18,00,000 | 19,80,000 ₹19,80,000 | 21,97,160 ₹21,97,160 | 16,01,000 ₹16,01,000 | 22,00,000 ₹22,00,000 | 20,58,318 ₹20,58,318 | 17,12,700 ₹17,12,700 |
| 2.01 | (a) Purification Technology :- No filters, No solvents, No Chemicals
(b) Pollution Captured : PM 2.5 to PM 10
(c) Electric Supply : 220 Volts AC
(d) Back Pressure: No advance impact on Engine
(e) Material : Mild Steel
(f) Reported PM Reduction: 80% to 90% (ARAI and other NABL accredited Labs)
(g) By Product : Soot Particles.
(h) Disposal : NO burning or dumping of captured partured particles.
(i) Collection of captured Particles : Once in 02 Months.
(j) Capturing Chamber Material: Stainless Steel.
(k) Mechanicial Pressure Release valve shoud be available.
(l) Sensors (Temp & Pressure) should be avoidable.
(m) Bypass System Should be available. | - | - | - | - | - | - | - | - | - | - |
| 2.02 | NOTE :
(i) RECD should be tested by any of the authorised / recogonised Central Pollution Control Board approved by GE and test certificate should be produced befor installation of RECD in the Generator Set.
(ii) The quoted rate shall be inclusive for the complete jobs and no additional / extra Payement shall be allowed
[a] Taking down and removing the existing silencer pipe with connected items and make necessary arrangements as required for fixing / connectiong RECD
[b] Suitable size pipe of required length
[c] Wiring with suitable size Copper cable from DG Control Panel.
[d] Test report shall be submitted after commissioning and testing of emission as per standard instructions and as directed by Engineer-in-Charge.
(iii) The unit rate quoted shall be deemed to include the cost of two years maintenance of RECD from the certified date of completion of work. | - | - | - | - | - | - | - | - | - | - |
Tender Value
₹35.7 L
EMD Value
₹71,400
Closing Date
14 Jul 2025, 6:55 pmClosed
Garrison Engineer (I) (CG) Chennai
Garrison Engineer (I) (CG), P-16, CGRA Meenambakkam 4th Street NGO Colony, Nanganallur, Chennai 600 061
PROVISION OF RETROFIT EMISSION CONTROL DEVICE FOR DG SETS AT NEW MRCC CHENNAI UNDER GE (I) (CG) CHENNAI
2025_MES_713680_1
8215/E8
Open Tender
Civil Works
Item Rate
153 days
CHENNAI
As per tender documents
8 documents required · 8 mandatory
₹500
Garrison Engineer (I)(CG) Chennai
₹71,400
Yes
11 Aug 2025
11 Jun 2025
16 Jul 2025
11 Jun 2025
14 Jul 2025
24 Jun 2025
12 Jun 2025 - 20 Jun 2025
Amount
Supply, install, testing and commissioning of Retrofit Emission Control Device (RECD) suitable for existing Diesel Generator Set of any make and model of 320 KVA capacity complete all as specified and as directed with following specification:-.
(a) Purification Technology :- No filters, No solvents, No Chemicals (b) Pollution Captured : PM 2.5 to PM 10 (c) Electric Supply : 220 Volts AC (d) Back Pressure: No advance impact on Engine (e) Material : Mild Steel (f) Reported PM Reduction: 80% to 90% (ARAI and other NABL accredited Labs) (g) By Product : Soot Particles. (h) Disposal : NO burning or dumping of captured partured particles. (i) Collection of captured Particles : Once in 02 Months. (j) Capturing Chamber Material: Stainless Steel.
(k) Mechanicial Pressure Release valve shoud be available. (l) Sensors (Temp & Pressure) should be avoidable. (m) Bypass System Should be available. NOTE : (i) RECD should be tested by any of the authorised / recogonised Central Pollution Control Board approved by GE and test certificate should be produced befor installation of RECD in the Generator Set. (ii) The quoted rate shall be inclusive for the following jobs and no additional / extra Payement shall be allowed [a] Taking down and removing the existing silencer pipe with connected items and make necessary arrangements as required for fixing / connectiong RECD [b] Suitable size pipe of required length [c] Wiring with suitable size Copper cable from DG Control Panel. [d] Test report shall be submitted after commissioning and testing of emission as per standard instructions and as directed by Engineer-in-Charge. (iii) The unit rate quoted shall be deemed to include the cost of two years maintenance of RECD from the certified date of completion of work.
Supply, install, testing and commissioning of Retrofit Emission Control Device (RECD) suitable for existing Diesel Generator Set of any make and model of 625 KVA capacity complete all as specified and as directed with following specification:-.
(a) Purification Technology :- No filters, No solvents, No Chemicals (b) Pollution Captured : PM 2.5 to PM 10 (c) Electric Supply : 220 Volts AC (d) Back Pressure: No advance impact on Engine (e) Material : Mild Steel (f) Reported PM Reduction: 80% to 90% (ARAI and other NABL accredited Labs) (g) By Product : Soot Particles. (h) Disposal : NO burning or dumping of captured partured particles. (i) Collection of captured Particles : Once in 02 Months. (j) Capturing Chamber Material: Stainless Steel. (k) Mechanicial Pressure Release valve shoud be available. (l) Sensors (Temp & Pressure) should be avoidable. (m) Bypass System Should be available.
NOTE : (i) RECD should be tested by any of the authorised / recogonised Central Pollution Control Board approved by GE and test certificate should be produced befor installation of RECD in the Generator Set. (ii) The quoted rate shall be inclusive for the complete jobs and no additional / extra Payement shall be allowed [a] Taking down and removing the existing silencer pipe with connected items and make necessary arrangements as required for fixing / connectiong RECD [b] Suitable size pipe of required length [c] Wiring with suitable size Copper cable from DG Control Panel. [d] Test report shall be submitted after commissioning and testing of emission as per standard instructions and as directed by Engineer-in-Charge. (iii) The unit rate quoted shall be deemed to include the cost of two years maintenance of RECD from the certified date of completion of work.
EVEREST ENGINEERING WORKS (BID ID -3341922)
M/S N K POWER SYSTEMS AND PROJECTS (BID ID -3349943)
M/s SS Engineering Enterprises (BID ID -3341315)
DPS sales and services india (BID ID -3358387)
M/s Trade Linker Associates (BID ID -3341394)
rvelectricals (BID ID -3341805)
BHARAT ENGINEERS (BID ID -3358017)
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .