Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.9 LAccepted-AOC | L1 | Accepted-AOC Being L1 Bidder | |
| 2 | L2₹30.0 L+₹1.5 L (5.23%)Rejected-AOC | L2 | Rejected-AOC Not L1 Bidder | |
| 3 | L3₹30.8 L+₹2.3 L (8.00%)Rejected-AOC G 58 KIRAN GARDEN UTTAM NAGAR NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | L3 | Rejected-AOC Not L1 Bidder | |
| 4 | L4₹33.0 L+₹4.5 L (15.8%)Rejected-AOC | L4 | Rejected-AOC Not L1 Bidder | |
| 5 | L5₹34.8 L+₹6.3 L (22.0%)Rejected-AOC | L5 | Rejected-AOC Not L1 Bidder |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
7 Nov 2022, 6:00 pmClosed
GE U WATER SUPPLY DELHI CANTT 10
GE U WATER SUPPLY DELHI CANTT 10
CERTAIN REPAIR TO CHLORONOME PLANTS RO PLANTS DG SETS REPAIR TO WATER LEVER INDICATORS PRIMING SYSTEM LIGHTENING PROTECTION EARTHINGS PITS AND FITTINGS AND FIXTURES SECURITY LIGHT OF VARIOUS INSTALLATIONS WITH ALLIED WORKS IN THE AREA OF AGE U WS II
2022_MES_551555_2
8222/GE/WS/D-35/2022-23
Open Tender
Civil Works
Item Rate
180 days
GE U WATER SUPPLY DELHI CANTT 10
CERTAIN REPAIR TO CHLORONOME PLANTS RO PLANTS DG SETS REPAIR TO WATER LEVER INDICATORS PRIMING SYSTEM LIGHTENING PROTECTION EARTHINGS PITS AND FITTINGS AND FIXTURES SECURITY LIGHT OF VARIOUS INSTALLATIONS WITH ALLIED WORKS IN THE AREA OF AGE U WS II
5 documents required · 5 mandatory
₹500
GE U WATER SUPPLY DELHI CANTT 10
₹80,000
Yes
20 Jan 2023
18 Oct 2022
9 Nov 2022
18 Oct 2022
7 Nov 2022
25 Oct 2022
Amount
Preventive maintenance of electric motor driven Chlorine dosing system of any make including cleaning of electrode rod , HDPE/FRP tank of capacity up to 150 Ltr tank and checking functioality and performance of level gauge, dosing pump, High pressure single head gear motor ,pressure gauge, power pack incl oiling and greasing of all moving parts under GE(U) Water supply Delhi Cantt. Note :Spare parts reqd for replacement in maintenance work will be measured & paid in relevent items.
Opening the motor of capacity 0.5HP, rewinding the motor with super enamelled copper wire of existing gauge, weight etc including varnishing cleaning, insulating material etc complete reparing the same by replacing the unserviceable spare parts and re-assembling the motor in orignal position to make it functional complete all as specified and as directed.
Supply only of gear motor 230 volt 50 Hz suitable for decrine dosing pump Part No PM 682 CE
Supply only of Rotor assembly with bearing brackets and tolerance rings Part No PMBR PL2
Supply only of Coil 250 volt, 50Hz Part No. MP 6 J222
Supply only of Single head feed rate control with shaft. Part No FC 5040D
Supply only of Pump head (Ferrules 1/4" including duckbill Part No UCPH 7 FD
Supply only of Roller assembly Part No. MC3ASYD`
Supply only of Pump tube. Part No MCCP 207
Supply only of Injection check valve 3/8" Part No MCINJ 38
Supply only of Weighted suction line strainer 3/8" Part No. ST 138
Supply only of White suction/discharge tube Part No. MAL T002
Supply only of chloroscope for water testing range of 0.1 ppm to 2.0 ppm
Supply only of ORTO-TOLUDINE regent solution in 500 ml bottle
Supply only of first Aid kit (PVC container) as per the specification including first aid medical treatment materials complete . (Note : All the medicine and First Aid will be of latest date and should be having atlest 12 months expiry date from the date of actual supply)
Supply only Knob of speed/stroke complete all as specified and directed.
Supply only main indicator lamp assembly complete.
Supply only valve seat cap of suction/discharge complete all as specified and directed.
Supply only fixing bolts made of stainless steel or supplied by OEM only
Supply only main indicator lamp assembly
Supply only Diaphragm seal
Supply only Diaphragm
Supply only Shaft(Diaphragm)
Supply only strainer only(Foot valve)
Supply only Pipe(Discharge/suction)
Supply only Foot valve assembly (complete with ball,seal &spring)
Supply only pulser circuits & speed potentiometer
Supply only power transformer.
Supply only fuse assembly including fuse complete all as specified and directed.
Supply and fixing in replacement of 2.5 sqmm 3 core flexible copper conductor cable suitable for exisiting unserviceable DBs/Power point etc
Supply and fixing in replacement of antisyphon valves (comlete with ball, seal & Spring) complete all as specified and directed.
Supply and fixing in replacement of FRP tank of capacity 100 Ltrs as per existing at site
Supply and fixing in replacement of FRP tank of capacity 150 Ltrs as per existing at site
Supply and fixing in replacement of 15 Amp 3 pin plug top
Supply and fixing in replacement of FRP construction solution preparations cum settling Tank with level gauge, lid, inlet / outlet connection, drain connection and fitted with speed reducer, motor and SS agitator of capacity 100 Ltr complete all as specified and directed.
Supply and fixing in replacement of FRP construction solution preparations cum settling Tank with level gauge, lid, inlet / outlet connection, drain connection and fitted with speed reducer, motor and SS agitator of capacity 150 Ltr complete all as specified and directed.
Supply only of PVC/rubber Hand glove suitable for handling of liquid Chlorine ISI marked complete all as specified and directed.
Material & Labour for comprehensive maintenance including all consumable chemicals (Pelican-319/ or As suitable for the RO plant existing at site) etc. of Reverse Osmosis Plant of 1 x 100 LPH, 1 x 500 LPH and 1 x 1000 LPH capacity installed in the AOR of GE (U) Water Supply AOR comprising of the following items:-(38.01 to 38.24)
Raw water feed/Backwash/CIP Pump with SS 304 impeller (CNP/Eqvt standard make) of capacity 6 Meter cube/Hour at 3 Kg/centimeter squared pressure - 03 Nos
FRP dual media filter of size 30" x 72" or suitable at site for the respective model of RO - 02 Nos
Anti scalant dozing system (i) HDPE dozing tank of capacity 100 lts - 02 Nos (ii) Dozing pump 0.5 LPH, PP or eqvt - 01 No
Micron Cartridge filter suitable for 6 cubic meter/hour for micron filter with PVC housing (Gopani), PP Cartridges - 01 lot
High Pressure pump of 6 cubic meter/hour at 14.5 kg/centrimeter squared pressure, SS -304 Impeller vertical centrifugal type (CNP or equivalent) - 02 Nos
TFC (CPA2-8040) RO Membrane of size 8" x 3 Nos - 01 Lot
FRP RO Pressure tube 8" , 3 Elements long, 250 PSI - 01 Nos
HDPE pH dozing tank of capacity 100 ltrs - 02 Nos
pH Dozing pump 0.5 LPH, PP or equivalent - 02 Nos
MSEP Skld - 02 Nos
MSPC Control Panel - 01 Nos
HDPE CIP Tank capacity - 500 ltr - 01 Nos
CIP micron cartridge filter of suitable size with PP/PVC housing, PP Cartridges - 01 lot
SS Solenoid Valve - 01 No
UPVC low pressure piping - 01 lot
Flow indicator - 01 lot
Pressure guage - 01 lot
Pressure switch low and high - 02 Nos
Conductivity indicator - 01 Nos
Level switch - 01 Nos
5 micron cartridge filter suitable for 6 cubic meter/hr frol with PVC housing (Gopani), PP Catridges
CIP micron cartridges filter of suitable size with PP/PVC housing, PP cartridges
Sodium bicarbonate for pH control - As required basis
Antiscalent liquid
Note : (A) RO Plant of above mentioned capacities of continues runs for 08 hours including all items taken in item Ser No 38 should be capable to work on the following water characteristics of inlet water :- (i) Total Hardness > 200 mg/ltr (ii) Chloride (as Cl) > 200 mg/ltr, TDS > 300 mg/ltr (iv) pH above 7.7, (v) iron > 0.22 mg/ltr (vi) Fluoride (as F) content > 0.44 mg/ltr. (B) Treated water characterisctic at the outlet of the RO plant must be : (i) TDS < 140 ppm (mg/ltr) (ii) Total Hardness , 25 ppm (mg/ltr) (iii) pH value - NEUTRAL.
Test sampling of drinking water being collected from RO outlet and RO inlet (Raw water) and submission of detailed test report from NABL accreditated Laboratory to GE/Engr-in-Charge fortnightly. (a) Collection of water sample from Pump House in presence of Engr-in-Charge/JE assigned the task, in Starlized bottles and testing in Govt approved lab as mentioned in specification. (b) Carrying out minimum essential testing of water as per IS 10500-1991 mandatory for presence of any Chemical, colour, odour, Taste, turbidity, pH Value, TDS, Total Hardness, Iron, Chloride, Fluoride, residual free Chlorine and bacteriological collie form from micro-organism per 100 ml (MPN) and to this office with specific recommendation regarding suitability of water for drinking purposes.
NOTE:- Rate quoted shall deemed to be included for :- (i) Cost of Sterilized Bottles as required (ii) To and fro transportation charges for collection of samples from sources.
M&L for Periodical mainteneance of DG Set capacity 250 KVA Make- kirloskar , by replacing fuel filter , Lub oil filter , by pass filter , air cleaner inner and outer element , water seperator, engine oil of suitable grade as per OEM recommendation upto upper level, cleaning of diesel tank thoroughly , cleaning of radiator after removing of old coolant completely with water and LIQUI MOLY Radiator Cleaner agent Cat Part No 48205 as recommended by manufacturer Make- Cummins installed at Arjan vihar pump house complete all as specified and directed. (Note :- Fuel filter , Lub oil filter , by pass filter , air filter shall be replaced under respective items of this Sch and all other items will be inclusive in this Job including Engine Oil and Coolant etc).
Supply and fixing in replacement of the following items of DG Sets 250 KVA Make- kirloskar , Model- installed at Arjan vihar pump house including taking out existing unserviceable items:-
Fan belt as per sample
V Belt, as per sample
Lub oil filter as per sample
Fuel filter element as per sample
By pass oil filter as per sample
Air cleaner, inner element and outer set as per sample
M&L for Periodical mainteneance of DG Set capacity 160 KVA Make- Cotton Greaves, by replacing fuel filter, Lub oil filter, by pass filter, air cleaner inner and outer element , water seperator, engine oil of suitable grade as per OEM recommendation upto upper level, cleaning of diesel tank thoroughly, cleaning of radiator after removing of old coolant completely with water and LIQUI MOLY Radiator Cleaner agent Cat Part No 48205 as recommended by manufacturer Make- Cummins installed at Harbux stadium & cavillary Hill complete all as specified and directed (Note :- Fuel filter, Lub oil filter, by pass filter, air filter shall be replaced under respective items of this Sch and all other items will be inclusive in this Job including Engine Oil and Coolant etc).
Supply and fixing in replacement of the following items of DG Sets 160 KVA Make- Cotton Greaves , Model- installed at Harbux stadium & cavillary Hill including taking out existing unserviceable items:-
Fan belt as per sample
V Belt, as per sample
Lub oil filter as per sample
Fuel filter element as per sample
By pass oil filter as per sample
Air cleaner, inner element and outer set as per sample
M&L for Periodical mainteneance of DG Set capacity 125 KVA Make- kirloskar, cummins & Mahidra & Mahindra , by replacing fuel filter , Lub oil filter , by pass filter , air cleaner inner and outer element , water seperator, engine oil of suitable grade as per OEM recommendation upto upper level, cleaning of diesel tank thoroughly , cleaning of radiator after removing of old coolant completely with water and LIQUI MOLY Radiator Cleaner agent Cat Part No 48205 as recommended by manufacturer Make- kirloskar, cummins & Mahidra & Mahindra installed at DK part -I pump House, Parade Road Pump House complete all as specified and directed (Note :- Fuel filter , Lub oil filter , by pass filter , air filter shall be replaced under respective items of this Sch and all other items will be inclusive in this Job including Engine Oil and Coolant etc).
Supply and fixing in replacement of the following items of DG Sets 125 KVA Make- kirloskar, cummins & Mahidra & Mahindra , Model- installed at DK part -I pump House, Parade Road Pump House including taking out existing unserviceable items: -
Fan belt as per sample
V Belt, as per sample
Lub oil filter as per sample
Fuel filter element as per sample
By pass oil filter as per sample
Air cleaner, inner element and outer set as per sample
M&L for Periodical mainteneance of DG Set capacity 100 KVA Make-Kirloskar/Ashoke Leyland/Cotton Greaves , by replacing fuel filter , Lub oil filter , by pass filter , air cleaner inner and outer element , water seperator, engine oil of suitable grade as per OEM recommendation upto upper level, cleaning of diesel tank thoroughly , cleaning of radiator after removing of old coolant completely with water and LIQUI MOLY Radiator Cleaner agent Cat Part No 48205 as recommended by manufacturer Make- Kirloskar /Ashok Leyland/cotton Greaves at STP Baird Place , RRRC Pump House, Sanjay Vihar P/H , Kabul line P/H, Arjan Vihar STP,OPC Pump House & Kabul Line pump House different location of STPs & Pump Houses, complete all as specified and directed (Note :- Fuel filter , Lub oil filter , by pass filter , air filter shall be replaced under respective items of this Sch and all other items will be inclusive in this Job including Engine Oil and Coolant etc).
Supply and fixing in replacement of the following items of DG Sets 100 KVA Make- Kirloskar/Ashoke Leyland/Cotton Greaves Model- installed at STP Baird Place , RRRC Pump House, Sanjay Vihar P/H , Kabul line P/H, Arjan Vihar STP,OPC Pump House & Kabul Line pump House different location of STPs & Pump Houses, including taking out existing unserviceable items: -
Fan belt as per sample
V Belt, as per sample
Lub oil filter as per sample
Fuel filter element as per sample
By pass oil filter as per sample
Air cleaner, inner element and outer set as per sample
M&L for Periodical mainteneance of DG Set capacity 90KVA Make-Kirloskar/Bosch , by replacing fuel filter , Lub oil filter , by pass filter , air cleaner inner and outer element , water seperator, engine oil of suitable grade as per OEM recommendation upto upper level, cleaning of diesel tank thoroughly , cleaning of radiator after removing of old coolant completely with water and LIQUI MOLY Radiator Cleaner agent Cat Part No 48205 as recommended by manufacturer Make- Kirloskar/Bosch (Urban Village P/H and Manekshaw Centre P/H) different location of STPs & Pump Houses, complete all as specified and directed (Note :- Fuel filter , Lub oil filter , by pass filter , air filter shall be replaced under respective items of this Sch and all other items will be inclusive in this Job including Engine Oil and Coolant etc).
Supply and fixing in replacement of following items of capacity 90 KVA (Urban Village P/H & Manekshaw centre P/H) and taking out the existing unserviceable items:-
Fan belt as per sample
V Belt, as per sample
Lub oil filter as per sample
Fuel filter element as per sample
By pass oil filter as per sample
Air cleaner, inner element and outer set as per sample
M&L for Periodical mainteneance of DG Set capacity 75 KVA Make-Kirloskar, by replacing fuel filter , Lub oil filter , by pass filter , air cleaner inner and outer element , water seperator, engine oil of suitable grade as per OEM recommendation upto upper level, cleaning of diesel tank thoroughly , cleaning of radiator after removing of old coolant completely with water and LIQUI MOLY Radiator Cleaner agent Cat Part No 48205 as recommended by manufacturer Make- Kirloskar (STP Cariappa Vihar) at different location of STPs & Pump Houses complete all as specified and directed. (Note :- Fuel filter , Lub oil filter , by pass filter , air filter shall be replaced under respective items of this Sch and all other items will be inclusive in this Job including Engine Oil and Coolant etc).
Supply and fixing in replacement of following items of capacity 75 KVA (STP Cariappa vihar) and taking out the existing unserviceable items:-
Fan belt as per existing at site
V Belt, as per existing at site
Lub oil filter as per existing at site
Fuel filter element as per existing at site
By pass oil filter as per existing at site
Air cleaner, inner element and outer set as per existing at site
M&L for Periodical mainteneance of DG Set capacity 63 KVA Make-Kirloskar, by replacing fuel filter, Lub oil filter, by pass filter, air cleaner inner and outer element , water seperator, engine oil of suitable grade as per OEM recommendation upto upper level, cleaning of diesel tank thoroughly, cleaning of radiator after removing of old coolant completely with water and LIQUI MOLY Radiator Cleaner agent Cat Part No 48205 as recommended by manufacturer (STP Kabul Lines and STP DK Part I) or at different location of STPs & Pump Houses, complete all as specified and directed. (Note :- Fuel filter , Lub oil filter , by pass filter , air filter shall be replaced under respective items of this Sch and all other items will be inclusive in this Job including Engine Oil and Coolant etc).
Supply and fixing in replacement of following items of capacity 63 KVA Make- Kirloskar (STP Kabul line &STP DK Part-1)and taking out the existing unserviceable items:-
Fan belt as per sample
V Belt, as per sample
Lub oil filter as per sample
Fuel filter element as per sample
By pass oil filter as per sample
M&L for Periodical mainteneance of DG Set capacity upto 50 KVA Make-Grives Cotton/mahindra/kirloskar (loc -Church Road,sanyat line,APS Colony,28 punjan STP& Engr Regt) by replacing fuel filter , Lub oil filte, by pass filter , air cleaner inner and outer element , water seperator, engine oil of suitable grade as per OEM recommendation upto upper level, cleaning of diesel tank thoroughly , cleaning of radiator after removing of old coolant completely with water and LIQUI MOLY Radiator Cleaner agent Cat Part No 48205 as recommended by manufacturer Make- Grives Cotton/mahindra/kirloskar (loc -Church Road,sanyat line,APS Colony,28 punjan STP& Engr Regt) or at different location of STPs & Pump Houses, complete all as specified and directed. (Note :- Fuel filter , Lub oil filter , by pass filter , air filter shall be replaced under respective items of this Sch and all other items will be inclusive in this Job including Engine Oil and Coolant etc).
M&L in replacement of following items of capacity upto 50 KVA Make-Grives Cotton/mahindra/kirloskar (loc -Church Road,sanyat line,APS Colony,28 punjan STP& Engr Regt) and taking out the existing unserviceable items:-
Fan belt as per existing at site
V Belt, as per existing at site
Lub oil filter as per existing at site
Fuel filter element as per existing at site
By pass oil filter as per existing at site
Air cleaner, inner element and outer set as per existing at site
M/L in replacement of AVR as per existing at site
M&L in replacement of Shut down Valve 24 volts as per existing at site
M&L in replacement of Battery Charging alternator with inbuilt regulator as per existing at site
M&L in replacement of Turbo charger reapair Kit as per existing at site
M&L in replacement of RPM cum hour meter as per existing at site .
M&L in replacement of Lub oil pump as per existing at site
M&L in replacement of heavy duty brass thimble for battery
M&L in replacement of Solonoid valve as per existing at site
M&L in replacement of Flexible fuel pipe as per existing at site
M&L in replacement of Set of gasket
M&L in replacement of High pressure pipe as per existing at site
M&L in replacement of radiator hose pipe as per existing at site
M&L in replacement of Air cleaner, inner element and outer set as per existing at site
M&L Dismantling the alternator assembly of DG set of capacity up to 250 KVA from the foundation after disconnecting the electric connection,carrying the same to workshop,dismantling of alternator and taking down worn out windings of rotor field coils and excitor coils,rewinding the stator,rotor and excitor gauge,replacement of insulation material,heat varnishing provision of connecting leads and terminal plates etc to make the alternator fully serviceable,reassembling the alternator shifting back to the installation ,assembling the same with engine making electric connections,testing and commissioning complete all as specified and directed.
M&L as in Repair of fuel injection pump (FIP) by dismantling and segregation all parts, replacement of new parts such as filter screen shut down valve, valve elbow, pulsation clamp, idle adjusting screw, high speed spring, governer plug, nozzle etc in replacement of existing U/S parts re-assembling the pump after repair/ replacement of parts and testing by celebration as per sample of cap 15 KVA to 63 K VA
M&L as in Reapir of fuel injection pump (FIP) by dismantling and segregation all parts, replacement of new parts such as filter screen shut down valve, valve elbow, pulsation clamp, idle adjusting screw, high speed spring, governer plug, nozzle etc in replacement of existing U/S parts re-assembling the pump after repair/ replacement of parts and testing by celebration as per sample of cap 75 KVA to 100 KVA.
M&L as in Repair of fuel injection pump (FIP) by dismantling and segregation all parts, replacement of new parts such as filter screen shut down valve, valve elbow, pulsation clamp, idle adjusting screw, high speed spring, governer plug , nozzle etc in replacement of existing U/S parts re-assembling the pump after repair/ replacement of parts and testing by celebration as per sample of cap 125 KVA to 250 KVA.
M&L as in Repair to self starter with replacement of carbon brushes,pinion,rewinding of starter and rotor winding, replacement of defective bents etc to make the starter fully serviceable and testing for DG Set.
M&L as in Repairs to radiator assembly Cleaning washing thoroughly with LIQUI MOLY Radiator Cleaner de- scaling incl M&L for replacement of rubberize parts and MS Nut & Bolts including brazing /repair of cooling tubes with dismantling and segregation upper and lower chamber (tank) including and reassembling any type any capacity complete all as specified and directed
M&L as in Repairs to DG Set of capacity 15-90 KVA control panel any type incl replacement defective sensors like AMF module, relay card / board ,current transformer, key switch, indiators, warning, push button and checking wiring complete including made functional all the system/controls complete all as specified and directed
M&L as in Repairs to DG Set of capacity 100-250 KVA control panel any type incl replacement defective sensors like AMF module , relay card / board ,current transformer, key switch, indiators, warning, push button and checking wiring complete including made functional all the system/controls complete all as specified and directed
M&L in replacement of Dynamo segregation of all parts supply and fix replacement of armature field, coil, carbon brush and bearing etc reassembling and testing.
supply and fixing in replacement of rotating rectifier diode sets ( forward - 3 nos & reverse - 3 nos) along with surge arrestors suitable for the following DG set of make: CUMMINS/Kirloskar/Ashok Leyland fixing and connecting in the circuit, starting and testing on load complete all as specified and directed
For Alternator of Capacity 100 KVA to 250 KVA
For Alternator of Capacity 15 KVA to 90 KVA
M&L in replacement of Electronic timers with auxilary voltage of 110/240/415v 50Hz for operation of 12-120 secs
M&L in replacement Automatic Float cum Boost Charger 12V/10-15A with protection Fuse and LED indications
M&L in replacement Automatic Float cum Boost Charger 24V/15-25A with protection Fuse and LED indications
M&L in replacement ACB Shunt release /tripping coll of110V/240V
M&L in replacement ACB Closing coll of 110V/240V
M&L in replacementAuxilary control Contactors /relays with Add On's
M&L in replacement power contactors Coils operatable at 110V/230V/440V 50Hz Supply
Power Contactor Coil For 250-160 KVA Alternator AMF
Power Contactor Coil For 125-15 KVA Alternator AMF
Supply and fixing in replacement of control panel suitable for DG set upto 250 KVA make- kirloskar(make shall as per existing at site to match the configaretion and make) including all connected items of Kirloskar model 15 KVA to 125 KVA, KG 934, KG 645, KG 745 and KG 545
Disconnecting unserviceable battery terminal and S&F of battery terminal brass heavy duty.complete suitable for fixing on battery poles with nuts and bolts complete all as specified and directed.
M&L in replacement of Jumper Cable with crocodile type strong grip clamps securily crimped on both ends and suitable to carry high current 4 Gauge x 20 Ft 500 A Heavy duty with travel Bag and Safety Gloves (4 AWG x 20 Ft) Make EPAuto complete all as specified and directed
Reapirs/ servicing to the stop Solonoid coil of capavity 12/24 Volt connected to the DG set of varoius capacity 200 to 15 KVA / any Makes as per existing at site including replacement of defective pars including winding complete all as specified and directed.
M&L for to carry out repairs to self starter by replcement of defective armature, field coils carbon brushes, soloniod, bearings reassembling the same and testing complete suitable for 24 volts/12 volts operation complete all as specified and directed
M&L in replacement of for to carry out repairs to 12/24Volt Alternator/dynamo by replacement of carbon brush, electronic regulator / rectifier, bearings reassembling the same and testing complete all as specified and directed.
M&L in replacement of Coolant Tempetarure Sensor suitable for 250-15 KVA Cummins/Kirloskar/Ashok Leyland/mahindra DG set connecting with panel circuit, starting and testing on load complete all as specified and directed
M&L in repair of old hinges and fixing new with fitting/welding as per existing size complete all as specified and as directed
M&L in replacement of rusted MS sheet at any portion of canopy and supply and fixing new sheet of 14 gauge with fitting/ welding and painting complete all as specified and directed
Material and Labour in repairs for DG set accoustic enclosure door Hinges /Aldrops/ locks with keys -02 sets including carring out necessary repirs/modifications suitable for DG set of capacity upto 250 KVA complete all as specified and directed
Taking out and replacement of unservicable/blocked/rusted MS pipe heavey duty 3” dia of length 2.00 meter.(NB) duly ISI marked, including thermal insulation with 50 mm thick glass wool of 48 kg .per cubic meter denisity , chiken wire mesh and cladding with 24 gauge aluminium sheet for exhaust of smoke of DG set including fixing the cladded pipe on MS support structure on the wall / celling including cutting, welding etc complete all as specified and directed
M&L in replacement old unserviciable maintanance Free Heavy duty Battery suitable for DG set of following
12V 180AH with 36 Months min warranty after necessary
12V 160AH with 36 Months min warranty after necessary
12V 100 AH with 36 Months min warranty after necessary
Taking down of the defective change over switch of the DG sets and Supply in replacement as per existing onload change over switch with auxilary contacts operatable at 440 V, 50Hz supply with enlosure operatable handle, 4 pole 200 Amp
M/L repair of test point terminal block made of steel plate of size 75x75x6 mm drilled and screwed including 3 nos 8 mm dia 25 mm long hex. head screw complete all as specified and directed
M&L in replacement aluminum strip 25x3.15mm as roof conductor or down conductor or along the pole/pipe complete with saddles/ insulators made out of porcelain or fibere and fixing screws complete all as specified and directed
M&L for Cleaning of semi under ground sumps storage capacity of water 3 lac gallons throughly by removing mud, grits incl 02 coat of white wash on concrete surface complete all as specified and as directed. Loc : CV Hill Pump House
M&L for Cleaning of semi under ground sumps storage capacity of water 1.75 lac gallons throughly by removing mud, grits incl 02 coat of white wash on conceret surface complete all as specified and as directed . Loc : Carrippa Viahr and Moude road Pump House
M&L for Cleaning of semi under ground/ under ground sumps storage capacity of water 0.6 lac to 1.00 lacs gallons throughly by removing mud, grits incl 02 coat of white wash on conceret surface complete all as specified and as directed. Loc :RCCC,LORRY ROAD , DKPART-I, AEPT, SANJAY VIHAR, APS COLONY, PARADE ROAD, URBAN VILLAGE, MANKSHAW ENCLAVE, CHURHCH ROAD, HARBUX STADIUM, OPC, NPC, BAIRD PLACE, MANKSHAW CENTER, NEW KABUL LINE, OLD KABUL LINE, SANYAT LINE, TIGRIS ROAD PUMP HOUSE Notes for srl Item Nos 102 to 104 :- Rates quoted shall deemed to includes for (i) Cleaning inner surfaces of tank complete by scrapping with steel wire brushes, pressure wash, removing mud, sludge collected inside the tank manually to a distance not exceeding 50 Mtrs. (ii) Washing with clean water & bleaching powder or with high strength calcium chloride mixture thoroughly internally, removing leftout sludge, if any, to a distance not exceeding 50 Mtrs including writing capacity of sump, cleaning date & due date of cleaning with black synthetic enamel paint complete as per existing pattern.
(iii) After hand over the under ground sump to contractor for cleaning purpose, sump will be clean within 24 hrs, other wise penalty will be deduct 1000 Rs/Hrs.
Supplying, fixing, jointing and testing in replacement of cast iron foot valve 100 mm bore , flanged ends pressure rating PN-0.2 operation with rubber sheet, swing type, confirming to IS- 4038 complete including taking out unserviceable foot valve complete all as specified and as directed .
Supplying, fixing, jointing and testing in replacement of cast iron foot valve 150 mm bore , flanged ends pressure rating PN-0.2 operation with rubber sheet, swing type, confirming to IS- 4038 complete including taking out unserviceable foot valve complete all as specified and as directed .
Opening of existing foot valve, of any make/ location, 100 mm to 300 mm bore, from UG sump, pump suction line for repairing/ servicing such as cleaning with & including replacement of foot valve sheet, nuts,bolts & washers etc as required and reassembling/ refixing at desired locations to make it functional complete all as specified and as directed .
Supply and fixing in replacement of mild steel work for manhole cover, stair case steps etc made of MS angle/ flats/channels of any size as required at site etc including cutting out top and bottom to shape as directed, drilling holes, notching for wire etc flat iron fillets including all necessary drilling, bolting or rivetting etc and similar works confirming to Fe-290, Gde E-165 and applying two coats of synthetic enamel paint over a coat of red oxide primer including preperation after demolition of existing covers,steps etc complete all as specified and as directed.
Taking down carefully copper/aluminium point wiring (light/fan/ socket/power) complete from the wall by cutting/ chasing including fittings and fixtures such as switches, ceiling roses, pendants holder, regulators,sockets,light fittings etc for credit and making good the disturbed surfaces of wall, floor etc complete all as specified and directed.
Taking down carefully sub main wiring/Service cable of any description.
Disconnecting elect connection and taking down of ceiling fan / Exaust fan of any make and any height, dismantling blade and removing fan alongwith blade for depositing in MES store yard complete all as specified and directed .
Taking down defective switch fuse main board / distribution iron clad or sheet metal enclosure/ MCB DBs with MCBs of any capacity and make including wooden board etc complete all as specified and directed.
M & L for Point wiring complete with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through and including non-metalic rigid new PVC conduit medium grade ISI Marked and all conduit accessories concealed in wall/ceiling/fixed to roof/truss/columns etc and including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuty, fabricated branded modular metal flush box duly make embossed, concealed in walls with suitable modular inner and outer plate for housing switches , socket out let and fan regulators etc, complete all as specified and directed for the followings:-
One light controlled by one, one way switch .
Ceiling fan/exhaust fan point controlled by one, one way switch .
One 3 pin 5 Amps socket outlet point controlled by one No one way switch on same board
One 3 pin 5 Amps socket outlet point controlled by one No one way switch on independent board.
All as per item No.5 herein before but with 4 sqmm cable for one 3 pin 15 Amp switch socket outlet and using 4 sqmm PVC single core copper conductor cable multistranded as earth wire complete all as specified and directed. Note for Item 6 & 7 : (i) In case the wiring is encountered with any beam/column, then the wiring will run on PVC conduit to avoid any damage to the RCC portion. (ii) No cutting shall be done in the roof for laying PVC conduit for ceiling fan point wiring, in this specified portion wires shall run through the surface new conduit shall be provided as mentioned in note (i) above. (iii) Proper colour code will be used for wiring as per the electrical rule and as directed
M&L in replacement of switch Piano type 6 Amps 230V AC complete all as specified and directed.
M&L in replacement of Piano socket outlet 5 pin 6 Amp socket 2 module complete all as specified and directed.
M&L in replacement of switch Piano type 16 Amps 230V AC complete all as specified and directed.
M&L in replacement of Piano socket outlet 5 pin 6/16 Amp universal socket 2 module complete all as specified and directed.
Supply and fix in replacement of LED batten luminaire surface mounted, 4 feet system wattage of 20Watts including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete all as specified and directed.
S & F in replacement of 50 W High efficient LED Street light fitting with pressure die cast Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover including provision of 40mm dia GI light grade pipe1.5 meter length bend to shape and necessary clamps etc for fixing the light fittings on wall fixed complete as specified and directed.
Material and labour Rewinding of ceiling fan 1200/1400 mm swipe with suitable gauge of enamelled copper wire complete and including with suitable class of insulating varnish including winding materials, attending lathe work to fan rotor shaft and including painting of ceiling fan with two coats of synthetic enamel paint and writing MES numbers complete all as specified and directed
Material and labour Rewinding of Ventilating Fan 450 mm sweep with suitable gauge of enamelled copper wire complete and including with suitable class of insulating varnish including winding materials, attending lathe work to fan rotor shaft and including painting of ceiling fan with two coats of synthetic enamel paint and writing MES numbers complete all as specified and directed
S&F MCB DB SPN 8 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete all as specified and directed
S&F MCB SPN upto 32 Amps 240 volts 10 KA 50 HZ 'C' curve complete all as specified and directed
S&F Ceiling rose, 3 phase/PVC/polycarbonate, isolated body complete all as specified and directed.
S&F MCB SP 6 - 32 Amps 240 volts 10 KA 50 HZ 'C' curve complete all as specified and directed .
M&L for Sub main wiring complete with FRLS PVC insulated unsheathed stranded copper conductor wire 4 Sq mm 02 Nos. (for Phase & Neutral) along with earth wire FRLS PVC insulated unsheathed stranded copper conductor wire of size 4 sq mm wire drawn through in & including PVC conduit 20 mm dia medium grade ISI marked including all fitting accessories fixed on wall/roofs/ceilings etc complete all as specified and directed. Note:- (i) Two runs of cable, one run of earth continuity conductor and one run of PVC conduit shall be measured as unit length. (ii) The damaged surfaces to be made good with plastering will be carried out by contractor and cost of the same deem to be included in the quoted rates. Nothing extra in this account will be admissible.
M&L in repair of earthing complete with GI electrode 600x 600 x 6mm, thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below normal ground level (with top edge of earth plate not less than 1.50 mtr below normal ground level connected to GI strip 32x6mm as earthing lead by means of bolt nuts, check nuts, and washers of brass connected including gun metal or phosphorus bronze of size 75x75x6 mm drilled and screwed including 3 Nos 8mm dia 25 mm long hexagonal head screwed all as specified including excavation and earth work and disposal of surplus soil incl 40 mm GI tubing light grade and necessary fitting for protection of GI strip incl laying of alternate layer of charcoal dust and common salt PPC (1:2:3) type C-1 (using 20mm graded stone aggregate) for earth pit with 40 x 40 x 6mm MS angle iron frame for cover 40 mm thick (1:2:4) type B20 using 12.5 mm graded stone aggregate reinforced with 8 mm dia round bar @ 75mm C/C both way with MS handle 20mm dia plastering 15mm thick CM (1:6) internally and upto 150mm below ground level externally PGL funnel with ground wire mesh 20mm dia GI pipe Medium grade for watering complete all as shown on electrical plate No 3 of SSR Part-1 2009 and connected in earth test incl testing completed all as specified and directed. Note:- Galvanised strip and protection light grade GI pipe upto 7.5 mtr shall be deemed to be in the rates.Galvanised strip shall be fixed on wall with suitable size of porcelain / PVC insulator.
M&L for painting on steel tubler pole with one coat of synthetic enamel paint as per existing colour scheme or pattern including preparation of old painted surface complete all as specified and directed
Note:- Sch of credit amount shall be deducted from total quoted BOQ Amount when work acceptance leter issued.
Surjit and Sons
Sumit Enterprises
ASHUTOSH BUILDERS
DHAIRYAE ENTERPRISES
Ridhi engineers and builders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .