Loading
Loading…
Loading…
Tender Value
Refer Docs
Closing Date
12 Dec 2023, 3:00 pmClosed
PR & CC
This tender is floated for DG Solar synchronization at Bahadurgarh and Hisar Terminal HPCL
2300008506-HD-01216
5100008506
Open Tender
Hisar, Haryana
₹0
Exempted
12 Dec 2023
1 Dec 2023
12 Dec 2023
12 Dec 2023
8 Dec 2023 - 10 Dec 2023
| Item No | Item Title | Description | Qty | Unit |
|---|---|---|---|---|
| 1 | INST - DG | INST - DG — STALLATION OF DG SYNCHRONISING PANEL-OUTDOORAREA. SHIFTING FROM CLIENT'S STORE AND ERECTIONON FOUNDATIONS, ASSEMBLING OF ALL LOO SUPPLIEDACCESSORIES AND INSTALLATION OF ABOVE. ITINCLUDES DESIGN, CONSTRUCTION OF SUITABLEFOUNDATION/MOUNTING ARRANGEMENT, SU LY ANDFINISHING OF JOB INCLUDING LABOURS, TOOLS ANDTACKLES COMPLETE IN ALL RESPECTS AND TAKINGAPPROVAL FROM HPCL'S ENGINEER-IN HARGE.INSTALLATION INCLUDES SUPPLY AND FABRICATION OFSTRUCTURAL STEEL FRAME AS REQUIRED.(APPROXIMATEDIMENSION-3000 MM (L) X 10 MM (D) X 2375 MM (H)) | - | Each |
| 2 | LICENSE FEE | LICENSE FEE — CENSE FEE FOR GRANT OF LICENSE FOR RESIDUEUP-GRADATION FACILITY (RUF). | - | Lump Sum |
| 3 | TESTING AND | TESTING AND — STING , PRE COMMISIONING , COMMISSIONING ANDSAT OF SYSTEM | - | LOT |
| 4 | SPLY&INSTLN OF MULTIFUTN | SPLY&INSTLN OF MULTIFUTN — PPLY AND INSTALLATION WITH 3 CT AND WIRE LUGS,3 LINE 3 DIGITS LED DISPLAY, VOLTAGE, AMPERE,FREQUENCY MULTIFUCTION METER. | - | Each |
| 5 | LAYING OF CABLE PAIR 1 X | LAYING OF CABLE PAIR 1 X — YING OF 1PX1.5 SQMM FRLS SIGNAL CABLE. DG SOLAR SYNCHRONIZATION AT HISAR TERMINAL Manadatory: No | - | meter |
| 1 | Supply & Installation of MFM | Supply & Installation of MFM — STER METER FLOWMETER,MASS; MANUFACTURER:N/A;MODEL:N/A; PRESSURE DESIGN,FLANGE:N/A; ADDITIONALINFORMATION:SIZE:3 IN; INGRESS PROT TION:MIN IP65; RANGE,INSTRUMENT:200/1400/2400 LPM; FOR WHITEOIL CONFIRMING AND IEC/ EN60529 AND CUSTODYTRANSFER APPROVAL AS PE OIML R117 ANDCOMMUNICATION OVER RS 485 AND OTHERSPECIFICATIONS AS PER TENDER SPECIFICATIONS ANDAPPROVED DATASHEETS ADDITIONAL CCESSORIES:INLET/OUTLET ISOLATION BALL VALVESIZE 3""CLASS ANSI 150RF WITH BLIND FLANGE CLASSANSI 150#, SS HOSE PIPE SIZE 4'' LE TH MINIMUM 5METER WITH CONNECTION FLANGE OF 3'' ON ONE SIDEAND 4'' ON OTHER SIDE , POWER CONNECTION :MALE &FEMALE SINGLE PHASE LP POWER SOCKET & QUANTITYAS PER TENDER TERMS , DISPLAY UNIT LED TYPE FORBATCH WISE ACCOUNTING PURPOSE. MOUNTING: ONSKID,CHAS S MOUNTED WITH SITUABLE WHEELS FORTOWING AND MATERIAL OF TROLLEY SHOULD BE MSICMC /MS ISMB | - | Lump Sum |
| 2 | Supply & Laying of Comm. | Supply & Laying of Comm. — PPLY, INSTALLATION, TESTING AND COMMISSIONINGOF RS 485 INTERFACE FOR THE DN65 FLOW METER; ALLCOMPLETE AS PER THE DIRECTIONS OF GINEER-IN-CHARGE. | - | Each |
| 3 | Supply & Installation of DG sync | Supply & Installation of DG sync — PPLY, INSTALLATION, TESTING AND COMMISSIONINGOF DG SYNC PANEL: SUPPLY OF LT SWITCH BOARD,CUBICLE TYPE, MADE OUT OF 2 MM THICK CR SHEET,TOTALLY ENCLOSED, IP 42, FREE STANDING, FLOORMOUNTING, DUST AND VERMIN PROOF, INDOOR,COMPARTMENTALIZED, SUITABLE FOR OP ATION ON 3PHASE, 415 VOLT, 50HZ AC SYSTEM WITH BUS BARS,INCLUDING INTERNAL WIRING WITH SUITABLE SIZE HFFRWIRES/CABLE, INTERCON CTION, DULY POWDER COATEDWITH SEVEN TANK PROCESS ETC. THE PANEL SHALL BEFABRICATED FROM A FIRM HAVING CPRI CERTIFICATIONWITH T T CERTIFICATES FOR SIMILAR PANEL(REQUIRED FOR SHORT CIRCUIT RATING, TEMPERATURERISE AND IP CLASSIFICATION) AND WITH FOLLOWINGS TCHGEAR, METERING INSTRUMENTS AND ACCESSORIESETC. COMPLETE AS REQUIRED AS PER DRAWING ANDSPECIFICATION. INCOMER:1 1000 AMP, TRIP POLENEUTRAL, 50 KA, ELECTRICAL DRAW OUT TYPE ACB WITHMICROPROCESSOR BASED ADJUSTABLE OVER CURRENT ANDEARTH FAULT RELEASE, SYN RONIZING RELAY, RS 485COMMUNICATION FACILITY FOR GRID FEEDER-1 NOINCOMER 2: 400 AMP, TPN, 50 KA MOTORIZED MCCBWITH MICROPROCES R RELEASE, ICS=ICU WITHADJUSTABLE OVER CURRENT AND ADJUSTABLE SHORTCIRCUIT, RS485 COMMUNICATION FACILITY, DGSYNCHRONIZING RELA 1 NO. INSTRUMENTS: (0 TO 500) VOLT VOLTMETER FOR 3 PHASE, 4 WIRE OPERATIONWITH SELECTOR SWITCH, (0-500) AMP AMMETER FOR 3PHASE 4 WIRE OPERATION WITH SELECTOR SWITCH,200/5 AMP 15 VA CLASS 1 RESIN CAST CT, 80/5 AMP15 VA CLASS 1 RESIN CAST CT DIGITAL MULTI NCTION METERS, LED INDICATION LAMPS ETC. ASREQUIRED COMPLETE AS PER SINGLE LINE DIAGRAMBUSBAR: 1250 AMP TPN BUSBAR CHAMBER WITH LUMINIUM BUSBAR OUTGOINGS: 1250 AMP, TPN, 50KA, ELECTRICAL DRAW OUT TYPE ACB WITHMICROPROCESSOR BASED ADJUSTABLE OVER CURRENT A EARTH FAULT RELEASE, SYNCHRONIZING RELAY, RS 485COMMUNICATION FACILITY FOR GRID FEEDER-1 NO THEPANEL SHALL BE WITH BOTTOM ENTR TO RECEIVEINCOMING AND OUTGOING CABLE, ALL NECESSARYINTERCONNECTION AND ACCESSORIES AS PER PARTICULARSPECIFICATION AND SINGLE NE DIAGRAM. SCOPE OFSYNCHRONIZATION INVOLVES SYNCHRONIZING 2 NUMBEROF EXISTING 320 KVA DG SETS WITH PROPOSED 320 KVADG SET. | - | Each |
| 4 | License fee for portal & Online | License fee for portal & Online — STING AND COMMISSIONING OF DG SYNCHRONISINGPANEL-OUTDOOR AREA. | - | Each |
| 5 | Testing & Commissioning of | Testing & Commissioning of — STING AND COMMISSIONING OF DG SYNCHRONISINGPANEL-OUTDOOR AREA. | - | Each |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
2300008506-HD-01216.pdf
TENDER_DOCUMENT • 6.19 MB
Download all tender documents and submit your bid