| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | I₹9.4 CrAccepted-AOC 10 YUBRAJ PALACE OLD AFI ROAD CHANDMARI GUWAHATI 781003 | KAMRUP METRO | ASSAM | 781003 | ₹9.4 Cr | I | Accepted-AOC After adding both Technical and financial marks secured first position |
| 2 | II₹10.0 CrRejected-AOC | ₹10.0 Cr | II | Rejected-AOC After adding both Technical and financial marks secured second position |
| 3 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹9.6 Cr
EMD Value
₹19.2 L
Closing Date
20 Feb 2019, 2:00 pmClosed
Managing Director, ATDC Ltd.
Office of the Managing Director, Assam Tourism Development Corporation Ltd., Paltanbazar, Guwahati-8
Signature Projects under UTTORON Scheme Development of Maa Chandika Devalaya and Chand Sadagar Merghar Chaygaon Dakhin Kamrup Assam
2019_DOT_11820_1
ATDC/CS/590/2018/5445 dt. 07.02.2019
Open Tender
Civil Works - Others
Item Rate
730 days
Chaygaon, Dakhin Kamrup
Please refer Tender documents.
7 documents required · 7 mandatory
₹10,000
Yes
Managing Director, ATDC Ltd., Guwahati-8
₹19.2 L
Yes
Guwahati
11 Jan 2022
13 Feb 2019
20 Feb 2019
14 Feb 2019
20 Feb 2019
14 Feb 2019
18 Feb 2019
Amount
GUEST HOUSE BUILDING
GROUND FLOOR
EARTHWORK
EXCAVATION :
Earth work in excavation for foundation trenches of walls, retaining walls, footings of columns, steps and septic tank etc including refilling ( return filling ) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc.and removal of surplus earth with all lead and lifts as directed and specified in the following classifications of soils including bailing out water where necessary as directed and specified.
(A) Up to a depth of 2.00 m below the existing ground level.
(b) In hard/ dense soil
PLINTH FILLING:
Earth/sand filling in plinth in layers not more than 150 mm thick including necessary carriage, watering,ramming etc. complete as directed and specified including payment of land compensation forest royalty, sales taxe and other duties and taxes as may be necessary.
(c) With river sand or silt (predominantly non plastic)by truck carriage including loading and unloading.
CEMENT CONCRETE WORKS
PLAIN CEMENT CONCRETE WORKS
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, wall, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where neccessary shall be measured and paid separately).
(a) In prop 1 cement : 3 sand : 6 coarse aggregate by volume
Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg.of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed.
REINFORCED CEMENT CONCRETE WORKS
Providing and laying plain/reinforced cement concrete works including dewatering if necessary,and curing complete but excluding cost of from work and reinforcment for reinforced cement concrete work ( form work and reinforcement will be measured and paid separately)
Using mixture machine
(A)In sub-structure up to plinth level
Foundation, Fotting,columns with base,tie and plinth beam, grade beam, pilecap, base slab, retaining walls,walls,walls of septic tank, inspection pit and the like and other works not less than 100 mm thick up to plinth level.
P) Using admixture, plasticiser etc for air entraining, water reducing purposes including addition of agent for changing normal setting time of concrete as required.
b) M 20 grade concrete or Prorp.1:1.5:3
(B)In super structure from plinth level upto 1st floor level.
(ii)Columns, pillar, posts, struts, suspended floor, roof, landing, shelf, and support, balcony, lintel, sill band beam, girder, bressumer, cantilever, staircase(exceptspiral staircase and landing) including preparing the top surface and finishing of nosing.
P) Using admixture, plasticiser etc
b) M20 Grade concrete or prop 1:1.5:3
SHUTTERING /FORM WORKS
PLYBOARD SHUTTERING
Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in:
Columns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical face
Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties.
(a) For depth not exceeding 1.0M.
Flat Surfaces such as soffits of suspended floors, roofs, landings and the like.
Vertical surface such as walls (any thickness), parapet walls, partitions and the like including attached pilasters, butresses, plinth and string courses and the like.
Staircase with sloping or stepped soffits including risers and stringers but excluding Landing.
BRICK WORKS
Providing brick soiling in foundation and under floor with stone/best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering complete.
(a).Brick on flat soling.
(c).Stone soling of thickness 150mm.
Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed.
(I) In Sub-structure upto plinth level including dewatering if necessary
(b) In proportion 1:4.
100mm thick wall using Cellular Light Weight concrete block of Size 500x200x100mm conforming to IS-2185 Pt-3 or pt-4 in cement mortar of proportion 1: 5 including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding rod is to be provided at every 3 course interval and will be measured and paid separately)
FLOOR FINISH
Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department)
a) Normal range Somany/ Orient/Nitco /Varmora/Jhonson Make
ii) Of size 600mmx600mm and above
MARBLE FLOORING AT VERANDAH, COMMON LOBBY, PASSAGE AND RECEPTION LOUNGE ETC.
18 mm thick Marble stone slab flooring of sizes 1200x1200 including treads and risers of steps, skirting, laid over 20 mm thick base of cement plaster 1:6 (1 cement : 6 coarse sand) laid and jointed with grey cement slurry including rubbing and polishing complete with marble slab of specified quality and shade at all levels.
(i) Dungri slab
ANTISKID TILES
Providing Antiskid Tiles of approved quality size, shape not less than 8mm on floor, skirting over a cement mortar bed 15mm thick of 1:3 (1 cement: 3 coarse sand) approved make fix with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/ white cement complete at all level as specified and directed.
VITRIFIED
iii)Executive range-2 (Sizes 600 mm x600mm and above)
c). Tuscan Series- Gres Lepato
B) ON WALLS
Providing polished vitrified wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/white cement slurry mixed with approved pigment to match shade of tilesc complete at all levels as specified and directed. (coloured pigment should be in conformity with colour of tiles and as approved and directed by the department).
iii) Of size300mmx600mm and above
GRANITE CLADDING
Providing 18mm thick Granite slab on vertical face of pedestal laid over 10 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete as directed with approved quality of shade.
PLASTERING
10 mm thick Cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed.
b) In cement mortar 1:4
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed.
A) On rough side
b) In cement mortar 1:4
B) On fair side
b) In cement mortar 1:4
Extra over item no 6.2.1 to 6.2.3 for plastering on celling and soffits of stairs up to 1st floor level (instead of plastering on walls) including curing complete as directed.
Water Proofing Plastering
15mm thick plastering of the interior surface of concrete water tanks with cement mortar in prop 1:4 admixed with modified Styrene Butadiene Rubber based polymer like Sika Latex of Sika India Ltd./Dr. Sealkit Masterbond Latex (Asian Chemicals)/Rheomix 141 of BASF @ 200gms per bag of cement as specified and directed by the department complete.
Water Proofing treatment of toilet floor
Providing and applying over roof slab/ raft slab, two coats of waterproofing slurry like SikaTop Seal 107 of Sika India Ltd./Dr. Sealkit Flexbond AP 121 C (Asian Chemicals) ./ MASTERSEAL 550 @ 1.5kg per sq.m. per coat, by brush after proper surface preparation (surface preparation including thorough cleaning of surface to be measured and paid separately) as specified & directed by the Department complete.
FALSE CEILING
Supplying, fitting, fixing and painting where necessary (one coat primer and two coats of paint) M/ F suspended ceiling which includes G.I. perimeter channels of size 0.55mm thick (having one flange of 20mm and another flange of 30mm and a web of 27mm) along with perimeter of ceiling, screw fixed to brick wall/ partition with the help of nylon sleeves and screws, at 610mm c/c. Then suspending G.I. intermediate channels of size 45mm (0.9mm thick with two equal flanges of 15mm each) from the soffit at 1220mm c/c with ceiling angle of width 5mmx10mmx0.55mm thick fixed to soffit with G.I.cleat and steel expansion fasteners. Ceiling section of 0.55mm thickness having knurled web of 51.5mm and two equal flanges of 26mm each with lips of 10.5mm are then fixed to the intermediate channel with the help of connecting clip and in direction perpendicular to the intermediate channel at 457mm c/c, 9.5mm/ 12.5mm thick Gypboard.
False ceiling (Light Duty) with Moisture Resistant Board (conforming to IS:2095-1982) is then screw fixed to ceiling section with 25mm long drywall screws at 230mm c/c. Screw fixing is done mechanically either with screw driver or drilling machine with suitable attachment. Finally, the boards are to be jointed and finished so as to have a flush look which includes filling and finishing the tapered and square edges of the boards with jointing compound, joint paper tape and two coats of drywall topcoat suitable for Gypboard complete at all levels as specified and directed. (For light fittings, providing opening for doors, window, ventilators etc., cut out made with frame of perimeter channel supported suitably to be measured and paid separately as and where necessary).
12.5mm MRB
WALL PUTTY
Providing two coats of acrylic water based wall putty/ wall filler of Asian Paints/ Berger/ Dulux over concrete/ cement plaster/ brick walls and ceilings both internal and external after removing all the loosely adhering material from the wall/ ceiling surface with the help of emery stone, putty blade or wire brush, moistening the wall with the help of sufficient quantity of clear water as specified and directed by the department.
WALL PAINTING
CEMENT PRIMER
a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
Wall painting (two coats) with acrylic emulsion paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth.
(a).Acrylic Emulsion Paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac)
EXTEROR PAINTING
Finishing old/ new wall with water proofing weather coat smooth anti-fungal exterior painting of Apex brand of Asian Paints and of required shade after cleaning and clearing the surface etc. including scaffolding complete as directed at all levels (two coats)
PAINTING ON STEEL AND OTHER METAL SURFACE
Applying primary coat over new steel and other metal surface over 100m in width or girth after preparing the surface by throughly cleaning oil,grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper.
Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter.
(i).Surfaces over 100mm in width or girth.
b). High gloss (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
PAINTING ON WOOD AND WOOD WOOD BASED SURFACES
Applying priming coat over new wood and wood based surfaces over 100mm in girth/width after and including preparing the surface by throughly cleaning oil, grease, dirt and other foreign matter, sand papering and knotting.
(a). With ready mixed paint , Wood primer (pink)
Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surfaces of all dirt, dust and other foreign matter sand papering and stopping.
(i).Surfaces over 100mm in width or girth.
b). High gloss (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
REINFORCEMENT
Supplying,fitting and fixing in position reinforcement bars conforming to relevant I.S Code for R.C.C work/R.B walling including straightening cleaning cutting and bending to proper shapes and length as per details supplying and binding with 20G annealed black wire and placing in position with proper blocks supports chairs spacers etc.complete.(No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they included in the rate.)(upto 1st fl level).
a) From Primary Producer: TATA/SAIL/Jindal steel/Shyam steel/RINL
(i) TMT Corrosion resistant steel (CRS) reiforcement bar
COLLAPSIBLE / ROLLING SHUTTERS
Providing and fixing in position collapsible M.S. shutters with vertical channels 20mmx10mmx2mm braced with flat iron diagonals 20mmx5mm size with top and bottom rails of T-iron 40mmx40mmx6mm with 38mm dia steel pulleys complete with bolts and nuts, locking arrangements, stoppers, handles including applying a priming coat of red lead paint.
GRILL WORKS
Providing,fitting and fixing M.S grill of required pattern for windows/clerestory windows/opening with M.S flats at required spacing in frame all round,square or round M.S bars with round headed bolts and nuts or screws.
I. Plain grill
© Fixed to Brickwork/P.C.C/R.C.C
CHOWKATH
Providing wood work in frame (chowkaths) of doors, windows, clerestory windows and other similar works wrought, framed and fixed in position in contact with C.C or brick masonry wall including supplying, fitting and fixing with M.S. hold fast (40mmx3mmx250mm) as per design embeded in cement concrete block in proportion 1:2:4 and with two coats of kiricide oiling to the timber faces in contact with C.C and masonry as directed and specified.
(a) With sal wood
Providing, fitting and fixing factory made Santro Flush door shutters having core & cross bands fabricated from seasoned 1st class timber, 25mm core battens, 2.5mm to 3.5mm uniformly thick cross bands, styles & rails made from hardwood timber of width not less than 50mm, fixed to the door frames (chowkath) with necessary hinges, screws, bolts etc. as specified and directed at all levels (Door fixtures and fittings to be measured and paid seperately.)
(a) 30mm thick
Providing, fitting and fixing PVC Door shutters of 37mm (single panel seamless finish) of Syntex make, at all levels made of extruded sections in the configuration of 'A'.The overall dimension is 37mm x 90mm, with usual process variation having a wall thickness of 2mm with a variation of +0.03mm provided with all plastic reinforcement to avoid rusting. The shutter frame is mitred and joined at the corners by means of stainless steel screws.The corners of the shutter frame are being reinforced by polymeric reinforcement of the size 125mm x 250mm and the lock rail is reinforced by 45 x18 x255 size reinforcement.
The lock rail is made of extruded hollow PVC section in the configuration of 'H' having wall thickness of 2mm with a variation of +0.03mm and effective dimension of 37mm x 105mm. The infill is made of multi-chambered hollow PVC extruded panel having an effective dimension of 762mm x 20mm or less as per requirement with usual process variation having a wall thickness of 1mm +0.03mm.The entire door shutter should be provided with S.S. screws at appropriate places for rust free quality. (Door fixtures and fittings to be measured and paid separately.)
Providing , fitting , and fixing Syntex PVC door frame made out of extruded PVC section in an over all size of 50mm x 60mm having multi chamber cross section with maximum wall thickness of 2mm, +0.3mm with special polymeric reinforcement having an over all size of 30mm x 25mm width,150mm length at hardware location. The corner joints shall be either mitre cut and welded or joined by means of concealed cleats with necessary screws fitting.
Providing, fitting and fixing 38mm Melamine faced pre-laminated cellular core Flush Door with 9mm/12mm thick high density exterior grade laminated particle board fixed to the internal wooden frame of Sal/Hollock wood with Polyurestene central core, fixed to the chowkath with necessary hinges, screws, bolts etc. as specified and directed at all levels.(Door fixtures to be measured and paid separately.)
(b)With Nepal Board-Exterior Grade (One side Decorative)
(ii) 12mm thick
DOOR AND WINDOW FITTINGS
ALUMINIUM FITTINGS
Supplying,fitting,fixing anodised aluminium fittings of approved make,reasonably smooth,free from sharp edges and corners,flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc.complete.(anodised to bright natural matt &satin finished)
(a)Sliding door bolts
(ii)250mm x16mm
(b)Tower bolts
(iii)200mm x12mm
(c) Door handle
(iii)150mm
RAILING
Providing and fixing Stainless Steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature(wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i.e. fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of engineer in charge.(For payment, only weight of stainless steel member is to be considered. No extra payment for fixing accessories such as nuts, bolts, fasteners etc. will be considered)
WINDOW
Supplying and installing uPVC- Sliding Windows made out of Lead free, UV resistant green profile having "GREENLINE" mark of BIS standard uPVC multichambered sections of wall thickness 2.4mm with corners fusion welded, fully reinforced with Galvanized steel 1.5/2mm including interlock profile, glazing bead, grooving bead, brush seal, aluminum sliding track, stainless steel rollers, sealing wedge block, Espag, int handle, pop up handle, keeper, drain cap, fisher screws, packing pieces with all necessary stainlessness screws etc. complete as directed. The windows must be installed complete with all kinds of ironmongery including EPDM gaskets, bridging wedges and glass packers and with suitable water draining system. Application of silicon sealant from inside / outside of Dowcorning / GE or equivalent. With 5mm clear glass
(a) 2 Track Sliding Window with Flyscreen using uPVC section of sizes 88mm x 50 mm x 2.4mm thick wall for frame with inbuilt flyscreen track, 37mm x 61mm x 2.4mm thick wall for glass sash, 25mm x 49mm x 2.4mm thick wall for flyscreen sash and, Interlock: 43mm x 23mm (Glass Panel) (WINSTA KOMMERLING/ FENESTA/ ENCRAFT)
(i) 2-Panel with Toughten glass
Supplying and installing uPVC- Casement Windows made out of Lead free, UV resistant green profile having "GREENLINE" mark of BIS standard uPVC multichambered sections with corners fusion welded, fully reinforced with Galvanized steel 1.5/2mm including glazing bead, folding gasket, glazing gasket, friction stay, Espag handle, Espag, keeper, drain cap, run up block, fisher screws, packing pieces with all stainless steel screws complete as directed. The windows must be installed complete with all kinds of ironmongery including EPDM gaskets,bridging wedges and glass packers and with suitable water draining system. Fittings ROTO / GQ or Equivalent. Application of Silicon sealant from Inside / Outside of Dowcorning / GE or equivalent complete as directed. (FENESTA/ENCRAFT/WINSTA KOMMERLING)
(d) Single leaf Top hung Window using uPVC section of minimum sizes 58mm x 57mm x 2.4mm thick wall for frame, 58mm x 68mm x 2.4mm thick wall for glass sash With 5mm clear float glass (WINSTA KOMMERLING/ FENESTA/ ENCRAFT)
with Toughten glass
ANTI-TERMITE TREATMENT
PRE-CONSTRUCTION ANTI-TERMITE TREATMENT
Pre- construction anti-termite treatment at the bottom of foundation pits and walls on either side up to a height of 300 mm from bottom of the excavation made for column plinth beam, wall, trenches etc. by applying the emulsion @ 5(five) litres per square meter of the surface area before starting construction work(supplying of neccessary tools and accessories by the contractor) as per the direction of the Department complete.
a) with aqueous emulsion having concentration 1:19 with chloropirophose solution(tricel or equivalent) and water, i.e. 1% solution.
Pre construction anti - termite treatment by applying in the entire levelled area after plinth filling and before laying floor by applying the emulsion @ 5 (five) litres per square meter of the surface to be spread with light rodding so as to ensure proper absorption by the filled up earth (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete.
a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
Pre construction anti - termite treatment by applying the soil along the external perimeter of the building (after construction completed) to a distance close to the plinth wall as specified and as directed by the deptt. up to a depth of 300mm making rod holes along the line @ 150mm apart to a depth of 300mm and applying emulsion @ 4.5 litres per running meter ensure moistening of the soil with emulsion (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete.
a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
PLINTH PROTECTION
Providing plinth protection with bricks flat laid in cement mortar 1: 4 and finished with 15mm thick cement plaster in prop. 1:2 with a floating coat of neat cement finish.
Providing drain with brick work in cement mortar in proportion 1:5 with half brick thick side walls and 100mm thick C.C (1:3:6) base over one brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shuttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified.
ii). 300mm wide and average 250mm deep with bed slope 1 in 150 with initial depth of 100mm.
R.C.C. PILING WORK.
MACHINE DRIVEN PILES
Providing cast in-situ machine driven reinforced cement concrete piles of required bore-diameter, bulb diameter, lengths and with reinforcement as per specifications and drawings including using of Bentonite solution. (Reinforcement to be measured and paid seperately as per item no. 21.4.1)
(A) SINGLE UNDER- REAMED PILE
UNIFORM PILE
(II) Concrete Grade M25
iii) Pile dia 400 mm
REINFORCEMENT
Supplying,fitting and fixing in position reinforcement bars conforming to relevent IS code, for reinforced cement concrete works in piles including straightening, cleaning ,cutting and bending to proper shapes and length as per specifications and drawings . The rings should be welded with vertical reinforcements as per specified IS codes of practice.(Inclusive of lap length, hook,chair, bend, anchor...etc)
(A) TMT bar made of Primary producer (From Primary producer)
DISMANTLING/ DEMOLISHING WORK.
Demolishing RCC/PCC pile head of different diameters carefully without disturbing the remaining portion of the pile including opening out of the pile head to be demolishing by excavating the earth upto required depth and clearing the debris as directed.
MISCELLANEOUS
Extra for using admixture & plasticiser
(a) RCC grade M20
iv) Pile Dia 400 mm
PILES TESTS
ROUTINE TESTS
Routine test for test loading to 1.5 times the specified safe working load including construction of any test pile cap and dismantling the same after completion of test. (Rate for Safe working Load)
Initial test for test loading to 2 times the specified safe working load including construction of any test pile cap and dismantling the same after completion of test. (Rate for Safe working Load)
Empty boring for specified diameter piles from ground level to cut-off level.
d) Pile Dia 400 mm
Extra for boring specified diameter pile in high sub-soil water level requiring use of drilling mud and extra cement. (iv) 400 mm dia
GUEST HOUSE BUILDING
FIRST FLOOR
REINFORCED CEMENT CONCRETE WORKS
Providing and laying plain/reinforced cement concrete works including dewatering if necessary,and curing complete but excluding cost of from work and reinforcment for reinforced cement concrete work ( form work and reinforcement will be measured and paid separately)
Using mixture machine
(B)In super structure from plinth level upto 1st floor level.
(ii)Columns, pillar, posts, struts, suspended floor, roof, landing, shelf, and support, balcony, lintel, sill band beam, girder, bressumer, cantilever, staircase(exceptspiral staircase and landing) including preparing the top surface and finishing of nosing.
P) Using admixture, plasticiser etc
b) M20 Grade concrete or prop 1:1.5:3
Extra for each subsequent floor or part thereof above 1st floor level
SHUTTERING /FORM WORKS
PLYBOARD SHUTTERING (FORMWORK)
Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in:
Columns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical face
Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties.
(a) For depth not exceeding 1.0M.
Flat Surfaces such as soffits of suspended floors, roofs, landings and the like.
Vertical surface such as walls (any thickness), parapet walls, partitions and the like including attached pilasters, butresses, plinth and string courses and the like.
Staircase with sloping or stepped soffits including risers and stringers but excluding Landing.
BRICK WORKS
100mm thick wall using Cellular Light Weight concrete block of Size 500x200x100mm conforming to IS-2185 Pt-3 or pt-4 in cement mortar of proportion 1: 5 including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding rod is to be provided at every 3 course interval and will be measured and paid separately)
Extra for each subsequent floor or part thereof above 1st floor level
FLOORING &FLOOR FINISH
Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department)
a) Normal range Somany/ Orient/Nitco /Varmora/Jhonson Make
ii) Of size 600mmx600mm and above
ANTISKID TILES
Providing Antiskid Tiles of approved quality size, shape not less than 8mm on floor, skirting over a cement mortar bed 15mm thick of 1:3 (1 cement: 3 coarse sand) approved make fix with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/ white cement complete at all level as specified and directed.
VITRIFIED
iii)Executive range-2 (Sizes 600 mm x600mm and above)
c). Tuscan Series- Gres Lepato
B) ON WALLS
Providing polished vitrified wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/white cement slurry mixed with approved pigment to match shade of tilesc complete at all levels as specified and directed. (coloured pigment should be in conformity with colour of tiles and as approved and directed by the department).
iii) Of size300mmx600mm and above
Water Proofing Plastering
15mm thick plastering of the interior surface of concrete water tanks with cement mortar in prop 1:4 admixed with modified Styrene Butadiene Rubber based polymer like Sika Latex of Sika India Ltd./Dr. Sealkit Masterbond Latex (Asian Chemicals)/Rheomix 141 of BASF @ 200gms per bag of cement as specified and directed by the department complete.
Water proofing treatment of toilet floor
Providing and applying over roof slab/ raft slab, two coats of waterproofing slurry like SikaTop Seal 107 of Sika India Ltd./Dr. Sealkit Flexbond AP 121 C (Asian Chemicals) ./ MASTERSEAL 550 @ 1.5kg per sq.m. per coat, by brush after proper surface preparation (surface preparation including thorough cleaning of surface to be measured and paid separately) as specified & directed by the Department complete.
GRANITE CLADDING
Providing polished granite tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 15 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey / Sika / Pedelite / Rouf) /white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (Cement plastering to be measured and paid separately). (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department). (Walls means both interior and exterior walls).
(i) With Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)
PLASTERING
10 mm thick Cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed.
b) In cement mortar 1:4
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed.
A) On rough side
b) In cement mortar 1:4
B) On fair side
b) In cement mortar 1:4
Extra over item no 6.2.1 to 6.2.3 for plastering on celling and soffits of stairs up to 1st floor level (instead of plastering on walls) including curing complete as directed.
Extra over item no 6.2.1 to 6.2.3 for exterior plastering over wall for every addl floor or part thereof beyond 1st floor level including curing complete as directed.
b) On two coat plaster
FALSE CEILING
Supplying, fitting, fixing and painting where necessary (one coat primer and two coats of paint) M/ F suspended ceiling which includes G.I. perimeter channels of size 0.55mm thick (having one flange of 20mm and another flange of 30mm and a web of 27mm) along with perimeter of ceiling, screw fixed to brick wall/ partition with the help of nylon sleeves and screws, at 610mm c/c. Then suspending G.I. intermediate channels of size 45mm (0.9mm thick with two equal flanges of 15mm each) from the soffit at 1220mm c/c with ceiling angle of width 5mmx10mmx0.55mm thick fixed to soffit with G.I.cleat and steel expansion fasteners. Ceiling section of 0.55mm thickness having knurled web of 51.5mm and two equal flanges of 26mm each with lips of 10.5mm are then fixed to the intermediate channel with the help of connecting clip and in direction perpendicular to the intermediate channel at 457mm c/c, 9.5mm/ 12.5mm thick Gypboard.
False ceiling (Light Duty) with Moisture Resistant Board (conforming to IS:2095-1982) is then screw fixed to ceiling section with 25mm long drywall screws at 230mm c/c. Screw fixing is done mechanically either with screw driver or drilling machine with suitable attachment. Finally, the boards are to be jointed and finished so as to have a flush look which includes filling and finishing the tapered and square edges of the boards with jointing compound, joint paper tape and two coats of drywall topcoat suitable for Gypboard complete at all levels as specified and directed. (For light fittings, providing opening for doors, window, ventilators etc., cut out made with frame of perimeter channel supported suitably to be measured and paid separately as and where necessary).
12.5mm MRB
WALL PUTTY
Providing two coats of acrylic water based wall putty/ wall filler of Asian Paints/ Berger/ Dulux over concrete/ cement plaster/ brick walls and ceilings both internal and external after removing all the loosely adhering material from the wall/ ceiling surface with the help of emery stone, putty blade or wire brush, moistening the wall with the help of sufficient quantity of clear water as specified and directed by the department.
WALL PAINTING
CEMENT PRIMER
a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
INTERNAL PAINT
Wall painting (two coats) with acrylic emulsion paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth.
(a).Acrylic Emulsion Paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac)
EXTEROR PAINTING
SPECIAL WATHER PROOF COLOURING
Finishing old/ new wall with water proofing weather coat smooth anti-fungal exterior painting of Apex brand of Asian Paints and of required shade after cleaning and clearing the surface etc. including scaffolding complete as directed at all levels (two coats)
PAINTING ON STEEL AND OTHER METAL SURFACE
Applying primary coat over new steel and other metal surface over 100m in width or girth after preparing the surface by throughly cleaning oil,grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper.
Painting two coats (excluding priming coat) on new steel and other metal surface with alluminium paint of approved brand and manufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) and brushing to give an even shade including cleaning the surface of all dirt, dust and other foreign matter.
(a).Surfaces over 100mm in width or girth.
PAINTING ON WOOD AND WOOD WOOD BASED SURFACES
Applying priming coat over new wood and wood based surfaces over 100mm in girth/width after and including preparing the surface by throughly cleaning oil, grease, dirt and other foreign matter, sand papering and knotting.
(a). With ready mixed paint , Wood primer (pink)
Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surfaces of all dirt, dust and other foreign matter sand papering and stopping.
(i).Surfaces over 100mm in width or girth.
b). High gloss (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
REINFORCEMENT
Supplying,fitting and fixing in position reinforcement bars conforming to relevant I.S Code for R.C.C work/R.B walling including straightening cleaning cutting and bending to proper shapes and length as per details supplying and binding with 20G annealed black wire and placing in position with proper blocks supports chairs spacers etc.complete.(No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they included in the rate.)(upto 1st fl level).
a) From Primary Producer: TATA/SAIL/Jindal steel/Shyam steel/RINL
(i) TMT Corrosion resistant steel (CRS) reiforcement bar
Extra for each subsequent floor or part thereof above 1st floor level
GRILL WORKS
Providing,fitting and fixing M.S grill of required pattern for windows/clerestory windows/opening with M.S flats at required spacing in frame all round,square or round M.S bars with round headed bolts and nuts or screws.
I. Plain grill
© Fixed to Brickwork/P.C.C/R.C.C
CHOWKATH
Providing wood work in frame (chowkaths) of doors, windows, clerestory windows and other similar works wrought, framed and fixed in position in contact with C.C or brick masonry wall including supplying, fitting and fixing with M.S. hold fast (40mmx3mmx250mm) as per design embeded in cement concrete block in proportion 1:2:4 and with two coats of kiricide oiling to the timber faces in contact with C.C and masonry as directed and specified.
(a) With sal wood
Providing, fitting and fixing factory made Santro Flush door shutters having core & cross bands fabricated from seasoned 1st class timber, 25mm core battens, 2.5mm to 3.5mm uniformly thick cross bands, styles & rails made from hardwood timber of width not less than 50mm, fixed to the door frames (chowkath) with necessary hinges, screws, bolts etc. as specified and directed at all levels (Door fixtures and fittings to be measured and paid seperately.)
(a) 30mm thick
Providing, fitting and fixing 38mm Melamine faced pre-laminated cellular core Flush Door with 9mm/12mm thick high density exterior grade laminated particle board fixed to the internal wooden frame of Sal/Hollock wood with Polyurestene central core, fixed to the chowkath with necessary hinges, screws, bolts etc. as specified and directed at all levels.(Door fixtures to be measured and paid separately.)
(b)With Nepal Board-Exterior Grade (One side Decorative)
(ii) 12mm thick
Windows
Supplying and installing uPVC- Sliding Windows made out of Lead free, UV resistant green profile having "GREENLINE" mark of BIS standard uPVC multichambered sections of wall thickness 2.4mm with corners fusion welded, fully reinforced with Galvanized steel 1.5/2mm including interlock profile, glazing bead, grooving bead, brush seal, aluminum sliding track, stainless steel rollers, sealing wedge block, Espag, int handle, pop up handle, keeper, drain cap, fisher screws, packing pieces with all necessary stainlessness screws etc. complete as directed. The windows must be installed complete with all kinds of ironmongery including EPDM gaskets, bridging wedges and glass packers and with suitable water draining system. Application of silicon sealant from inside / outside of Dowcorning / GE or equivalent. With 5mm clear glass
(a) 2 Track Sliding Window with Flyscreen using uPVC section of sizes 88mm x 50 mm x 2.4mm thick wall for frame with inbuilt flyscreen track, 37mm x 61mm x 2.4mm thick wall for glass sash, 25mm x 49mm x 2.4mm thick wall for flyscreen sash and, Interlock: 43mm x 23mm (Glass Panel) (WINSTA KOMMERLING/ FENESTA/ ENCRAFT)
with Toughten glass
Supplying and installing uPVC- Casement Windows made out of Lead free, UV resistant green profile having "GREENLINE" mark of BIS standard uPVC multichambered sections with corners fusion welded, fully reinforced with Galvanized steel 1.5/2mm including glazing bead, folding gasket, glazing gasket, friction stay, Espag handle, Espag, keeper, drain cap, run up block, fisher screws, packing pieces with all stainless steel screws complete as directed. The windows must be installed complete with all kinds of ironmongery including EPDM gaskets,bridging wedges and glass packers and with suitable water draining system. Fittings ROTO / GQ or Equivalent. Application of Silicon sealant from Inside / Outside of Dowcorning / GE or equivalent complete as directed. (FENESTA/ENCRAFT/WINSTA KOMMERLING)
(d) Single leaf Top hung Window using uPVC section of minimum sizes 58mm x 57mm x 2.4mm thick wall for frame, 58mm x 68mm x 2.4mm thick wall for glass sash With 5mm clear float glass (WINSTA KOMMERLING/ FENESTA/ ENCRAFT)
with Toughten glass
DOOR AND WINDOW FITTINGS
ALUMINIUM FITTINGS
Supplying,fitting,fixing anodised aluminium fittings of approved make,reasonably smooth,free from sharp edges and corners,flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc.complete.(anodised to bright natural matt &satin finished)
(a)Sliding door bolts
(ii)250mm x16mm
(b)Tower bolts
(iii)200mm x12mm
(c) Door handle
(iii)150mm
t) Door stopper with rubber stopper
RAILING
Providing and fixing Stainless Steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature(wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i.e. fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of engineer in charge.(For payment, only weight of stainless steel member is to be considered. No extra payment for fixing accessories such as nuts, bolts, fasteners etc. will be considered)
GUEST HOUSE BUILDING
SECOND FLOOR
REINFORCED CEMENT CONCRETE WORKS
Providing and laying plain/reinforced cement concrete works including dewatering if necessary,and curing complete but excluding cost of from work and reinforcment for reinforced cement concrete work ( form work and reinforcement will be measured and paid separately)
Using mixture machine
(B)In super structure from plinth level upto 1st floor level.
(ii)Columns, pillar, posts, struts, suspended floor, roof, landing, shelf, and support, balcony, lintel, sill band beam, girder, bressumer, cantilever, staircase(exceptspiral staircase and landing) including preparing the top surface and finishing of nosing.
P) Using admixture, plasticiser etc
b) M20 Grade concrete or prop 1:1.5:3
Extra for each subsequent floor or part thereof above 1st floor level
SHUTTERING /FORM WORKS
PLYBOARD SHUTTERING (FORMWORK)
Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in:
Columns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical face
Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties.
(a) For depth not exceeding 1.0M.
Flat Surfaces such as soffits of suspended floors, roofs, landings and the like.
Vertical surface such as walls (any thickness), parapet walls, partitions and the like including attached pilasters, butresses, plinth and string courses and the like.
Staircase with sloping or stepped soffits including risers and stringers but excluding Landing.
BRICK WORKS
100mm thick wall using Cellular Light Weight concrete block of Size 500x200x100mm conforming to IS-2185 Pt-3 or pt-4 in cement mortar of proportion 1: 5 including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding rod is to be provided at every 3 course interval and will be measured and paid separately)
Extra for each subsequent floor or part thereof above 1st floor level
FLOORING &FLOOR FINISH
Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department)
a) Normal range Somany/ Orient/Nitco /Varmora/Jhonson Make
ii) Of size 600mmx600mm and above
ANTISKID TILES
Providing Antiskid Tiles of approved quality size, shape not less than 8mm on floor, skirting over a cement mortar bed 15mm thick of 1:3 (1 cement: 3 coarse sand) approved make fix with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/ white cement complete at all level as specified and directed.
VITRIFIED
iii)Executive range-2 (Sizes 600 mm x600mm and above)
c). Tuscan Series- Gres Lepato
B) ON WALLS
Providing polished vitrified wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/white cement slurry mixed with approved pigment to match shade of tilesc complete at all levels as specified and directed. (coloured pigment should be in conformity with colour of tiles and as approved and directed by the department).
iii) Of size300mmx600mm and above
Water Proofing Plastering
15mm thick plastering of the interior surface of concrete water tanks with cement mortar in prop 1:4 admixed with modified Styrene Butadiene Rubber based polymer like Sika Latex of Sika India Ltd./Dr. Sealkit Masterbond Latex (Asian Chemicals)/Rheomix 141 of BASF @ 200gms per bag of cement as specified and directed by the department complete.
Water proofing treatment of toilet floor
Providing and applying over roof slab/ raft slab, two coats of waterproofing slurry like SikaTop Seal 107 of Sika India Ltd./Dr. Sealkit Flexbond AP 121 C (Asian Chemicals) ./ MASTERSEAL 550 @ 1.5kg per sq.m. per coat, by brush after proper surface preparation (surface preparation including thorough cleaning of surface to be measured and paid separately) as specified & directed by the Department complete.
GRANITE CLADDING
Providing polished granite tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 15 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey / Sika / Pedelite / Rouf) /white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (Cement plastering to be measured and paid separately). (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department). (Walls means both interior and exterior walls).
(i) With Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)
PLASTERING
10 mm thick Cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed.
b) In cement mortar 1:4
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed.
A) On rough side
b) In cement mortar 1:4
B) On fair side
b) In cement mortar 1:4
Extra over item no 6.2.1 to 6.2.3 for plastering on celling and soffits of stairs up to 1st floor level (instead of plastering on walls) including curing complete as directed.
Extra over item no 6.2.1 to 6.2.3 for exterior plastering over wall for every addl floor or part thereof beyond 1st floor level including curing complete as directed.
b) On two coat plaster
WALL PUTTY
Providing two coats of acrylic water based wall putty/ wall filler of Asian Paints/ Berger/ Dulux over concrete/ cement plaster/ brick walls and ceilings both internal and external after removing all the loosely adhering material from the wall/ ceiling surface with the help of emery stone, putty blade or wire brush, moistening the wall with the help of sufficient quantity of clear water as specified and directed by the department.
WALL PAINTING
CEMENT PRIMER
a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
INTERNAL PAINT
Wall painting (two coats) with acrylic emulsion paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth.
(a).Acrylic Emulsion Paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac)
EXTEROR PAINTING
SPECIAL WATHER PROOF COLOURING
Finishing old/ new wall with water proofing weather coat smooth anti-fungal exterior painting of Apex brand of Asian Paints and of required shade after cleaning and clearing the surface etc. including scaffolding complete as directed at all levels (two coats)
PAINTING ON STEEL AND OTHER METAL SURFACE
Applying primary coat over new steel and other metal surface over 100m in width or girth after preparing the surface by throughly cleaning oil,grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper.
Painting two coats (excluding priming coat) on new steel and other metal surface with alluminium paint of approved brand and manufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) and brushing to give an even shade including cleaning the surface of all dirt, dust and other foreign matter.
(a).Surfaces over 100mm in width or girth.
PAINTING ON WOOD AND WOOD WOOD BASED SURFACES
Applying priming coat over new wood and wood based surfaces over 100mm in girth/width after and including preparing the surface by throughly cleaning oil, grease, dirt and other foreign matter, sand papering and knotting.
(a). With ready mixed paint , Wood primer (pink)
Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surfaces of all dirt, dust and other foreign matter sand papering and stopping.
(i).Surfaces over 100mm in width or girth.
b). High gloss (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
REINFORCEMENT
Supplying,fitting and fixing in position reinforcement bars conforming to relevant I.S Code for R.C.C work/R.B walling including straightening cleaning cutting and bending to proper shapes and length as per details supplying and binding with 20G annealed black wire and placing in position with proper blocks supports chairs spacers etc.complete.(No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they included in the rate.)(upto 1st fl level).
a) From Primary Producer: TATA/SAIL/Jindal steel/Shyam steel/RINL
(i) TMT Corrosion resistant steel (CRS) reiforcement bar
GRILL WORKS
Providing,fitting and fixing M.S grill of required pattern for windows/clerestory windows/opening with M.S flats at required spacing in frame all round,square or round M.S bars with round headed bolts and nuts or screws.
I. Plain grill
© Fixed to Brickwork/P.C.C/R.C.C
CHOWKATH
Providing wood work in frame (chowkaths) of doors, windows, clerestory windows and other similar works wrought, framed and fixed in position in contact with C.C or brick masonry wall including supplying, fitting and fixing with M.S. hold fast (40mmx3mmx250mm) as per design embeded in cement concrete block in proportion 1:2:4 and with two coats of kiricide oiling to the timber faces in contact with C.C and masonry as directed and specified.
(a) With sal wood
Providing, fitting and fixing factory made Santro Flush door shutters having core & cross bands fabricated from seasoned 1st class timber, 25mm core battens, 2.5mm to 3.5mm uniformly thick cross bands, styles & rails made from hardwood timber of width not less than 50mm, fixed to the door frames (chowkath) with necessary hinges, screws, bolts etc. as specified and directed at all levels (Door fixtures and fittings to be measured and paid seperately.)
(a) 30mm thick
Providing, fitting and fixing 38mm Melamine faced pre-laminated cellular core Flush Door with 9mm/12mm thick high density exterior grade laminated particle board fixed to the internal wooden frame of Sal/Hollock wood with Polyurestene central core, fixed to the chowkath with necessary hinges, screws, bolts etc. as specified and directed at all levels.(Door fixtures to be measured and paid separately.)
(b)With Nepal Board-Exterior Grade (One side Decorative)
(ii) 12mm thick
Windows
Supplying and installing uPVC- Sliding Windows made out of Lead free, UV resistant green profile having "GREENLINE" mark of BIS standard uPVC multichambered sections of wall thickness 2.4mm with corners fusion welded, fully reinforced with Galvanized steel 1.5/2mm including interlock profile, glazing bead, grooving bead, brush seal, aluminum sliding track, stainless steel rollers, sealing wedge block, Espag, int handle, pop up handle, keeper, drain cap, fisher screws, packing pieces with all necessary stainlessness screws etc. complete as directed. The windows must be installed complete with all kinds of ironmongery including EPDM gaskets, bridging wedges and glass packers and with suitable water draining system. Application of silicon sealant from inside / outside of Dowcorning / GE or equivalent. With 5mm clear glass
(a) 2 Track Sliding Window with Flyscreen using uPVC section of sizes 88mm x 50 mm x 2.4mm thick wall for frame with inbuilt flyscreen track, 37mm x 61mm x 2.4mm thick wall for glass sash, 25mm x 49mm x 2.4mm thick wall for flyscreen sash and, Interlock: 43mm x 23mm (Glass Panel) (WINSTA KOMMERLING/ FENESTA/ ENCRAFT)
with Toughten glass
Supplying and installing uPVC- Casement Windows made out of Lead free, UV resistant green profile having "GREENLINE" mark of BIS standard uPVC multichambered sections with corners fusion welded, fully reinforced with Galvanized steel 1.5/2mm including glazing bead, folding gasket, glazing gasket, friction stay, Espag handle, Espag, keeper, drain cap, run up block, fisher screws, packing pieces with all stainless steel screws complete as directed. The windows must be installed complete with all kinds of ironmongery including EPDM gaskets,bridging wedges and glass packers and with suitable water draining system. Fittings ROTO / GQ or Equivalent. Application of Silicon sealant from Inside / Outside of Dowcorning / GE or equivalent complete as directed. (FENESTA/ENCRAFT/WINSTA KOMMERLING)
(d) Single leaf Top hung Window using uPVC section of minimum sizes 58mm x 57mm x 2.4mm thick wall for frame, 58mm x 68mm x 2.4mm thick wall for glass sash With 5mm clear float glass (WINSTA KOMMERLING/ FENESTA/ ENCRAFT)
with Toughend glass
DOOR AND WINDOW FITTINGS
ALUMINIUM FITTINGS
Supplying,fitting,fixing anodised aluminium fittings of approved make,reasonably smooth,free from sharp edges and corners,flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc.complete.(anodised to bright natural matt &satin finished)
(a)Sliding door bolts
(ii)250mm x16mm
(b)Tower bolts
(iii)200mm x12mm
(c) Door handle
(iii)150mm
t) Door stopper with rubber stopper
RAILING
Providing and fixing Stainless Steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature(wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i.e. fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of engineer in charge.(For payment, only weight of stainless steel member is to be considered. No extra payment for fixing accessories such as nuts, bolts, fasteners etc. will be considered)
BARGE BOARD
Providing barge board of size 200mm x 20mm with 1st class local Hollock/ Bonsum timber including fitting and fixing with necessary wood screws etc. complete.
ROOFING SHEET
Providing Pre Painted Galvalume Sheet Roofing (PPGL) at all levels including fitting and fixing self drilling, self tapping screws complete (Roof trusses, purlins etc. to be measured and paid separately.)
TATA Blue scope/ Dyna roof / Wonder Roof or equivalent as directed by the Departement
(v) 0.60 mm thick
Providing Pre Painted Galvalume Sheet (PPGL) accessories ( Ridges / Valley / Gutter / Flashing) at all levels including fitting and fixing self drilling, self tapping screws complete. TATA Blue scope/ Dyna roof / Wonder Roof or equivalent as directed by the Departement
(v) 0.60 mm thick
ROOF TRUSS
Providing, fitting, hoisting and fixing of roof trusses fabricated out of combination of any two or all of the following sections (i) Square section (ii) Rectangular Hollow section of specification RSH/SHS and (iii) M.S. circular hlollow section of Grade 210 including purlins, bottom runners and providing M.S. cleat, M.S. angle base plank, bolts and nuts with red oxide primer including fitting bottom runner and cleat etc. for fixing ceiling joist as per design complete as directed as per specifications.
a) Using TATA make RHS/SHS of Grade 310 conforming to relevant I.S. code 4923 : 1997
FLY PROOF
Providing fly proof M.S. wire netting of I.S.gauge designation 85 with wire of dia 0.05 mm over hollock or other wood dressed frame including 1st class timber beading of 38mmx12 mm size chamfered including fitting, fixing with necessary wood screws etc.complete as directed (timber frame to be measured and paid separately).
ANGLES/FLATS/BOLTS AND NUTS
Supplying fitting and fixing M.S.angles, M.S. flat, M.S. bolts and nuts including painting with red lead paint one coat complete as directed.
b) M. S. Flats…….
FALSE CEILING
Supplying, fitting, fixing and painting where necessary (one coat primer and two coats of paint) M/ F suspended ceiling which includes G.I. perimeter channels of size 0.55mm thick (having one flange of 20mm and another flange of 30mm and a web of 27mm) along with perimeter of ceiling, screw fixed to brick wall/ partition with the help of nylon sleeves and screws, at 610mm c/c. Then suspending G.I. intermediate channels of size 45mm (0.9mm thick with two equal flanges of 15mm each) from the soffit at 1220mm c/c with ceiling angle of width 5mmx10mmx0.55mm thick fixed to soffit with G.I.cleat and steel expansion fasteners. Ceiling section of 0.55mm thickness having knurled web of 51.5mm and two equal flanges of 26mm each with lips of 10.5mm are then fixed to the intermediate channel with the help of connecting clip and in direction perpendicular to the intermediate channel at 457mm c/c, 9.5mm/ 12.5mm thick Gypboard.
False ceiling (Light Duty) with Moisture Resistant Board (conforming to IS:2095-1982) is then screw fixed to ceiling section with 25mm long drywall screws at 230mm c/c. Screw fixing is done mechanically either with screw driver or drilling machine with suitable attachment. Finally, the boards are to be jointed and finished so as to have a flush look which includes filling and finishing the tapered and square edges of the boards with jointing compound, joint paper tape and two coats of drywall topcoat suitable for Gypboard complete at all levels as specified and directed. (For light fittings, providing opening for doors, window, ventilators etc., cut out made with frame of perimeter channel supported suitably to be measured and paid separately as and where necessary).
12.5mm MRB
GUEST HOUSE BUILDING
SANITARY FITTINGS AND WATER SUPPLY WORKS
EUROPEAN TYPE WATER CLOSET
Providing fitting and fixing vitreous china pedestal type water closet (European type W.C pan 400mm high ) with seat and lead ,CP brass hinges and rubber buffers , CI/MS brackets , 40 mm dia flush band with fittings including painting of fittings and brackets, required. (Flushing Cistern to be paid separately)
C) Jaquar make
a) White
(vii) Wall mounted Closet Crystal (inclusive of seat cover and fittings) (Cat. No. 20047)
CONCEALED CISTERN
Supplying, fiting and fixing concealed cistern with all internal fittings with CI brackets including fitting and fixing standard size CP flush pipe, union clamps etc. compete as directed and specified (pipes will be measured separately)
A) Parryware make
(i) Rios with Chorme Push Plate (Cat no.8174/ Cat. No.C813726)
URINAL
Providing fitting and fixing vitreous china flat back type lipped front urinal basin with standard flush pipe and CP brass spreader and brass unions, etc. complete including painting of fittings and brackets, cutting and making good the walls & floors wherever required.
(C) Jaquar Make
(a) White
(iii) Large (Cat.No.URS-WHT-0703)
WASH BASIN
Providing vitreous china wash basin with CI/MS brackets ,C.P Brass chain with plug,PVC waste pipe including painting of fitting and brackets, cutting and making good the walls and slabs wherever required.( Pillar cock,stop cock, waste coupling are to be paid separately)
Table Top Basin
(C) Jaquar Make
(vi) JDBC (Cat. No.JDS-WHT-0547)
MIRROR
Providing fitting and fixing Decorative Mirror complete as directed and specified.
(A) Parryware Make
(a) Size 800mm x 600mm
SOAP TRAY, SOAP DISH, LIQUID SOAP DISPENSER AND LIQUID SOAP CONTAINER
Providing, fitting and fixing CP soap tray / soap dish complete as directed and specified.
(iii) Cera Make (Cat.No.CA-103)
TOWEL RAIL,TOWEL RACK & TOWEL RING
Providing fitting and fixing chrome plated (CP) towel rail of Jaquar make complete as directed and specified
(a) Jaquar make
(ii) Continental 600mm (Cat.No. ACN-1111N)
TOILET PAPER HOLDER
Providing, fitting and fixing Chrome Plated TOILET PAPER holder complete as directed and specified.
(a) Jaquar make
(ii) Continental toilet paper holder with flap (Cat.No. ACN-1153N)
WASTE COUPLING
Providing fitting and fixing chrome waste coupling (half thread HT and full thread FT)complete as directed and specified.
(a) Jaquar Make
(iii) Rupa 50mm (HT/ FT) (Cat.No.WS-0801)
BOTTLE TRAP
Providing, fitting and fixing chrome plate bottle trap complete as directed and specified.
(a) Jaquar make
(ii) Bottle trap (with internal partition) 32mm size with 300mm long wall connection pipe (Cat.No. ALD-769B)
PVC PIPES BENDS JUNCTIONS TEES ETC.
Supplying fitting and fixing PVC pipes of 6kgf/cmsq (Supreme/Prince)or other ISI approved including joining fitting and fixing with clamps etc.as necessary complete at all levels including below G.L as directed and specified.
(a)In exposed surfaces or in trenches
(i) 160mm dia.
(ii) 110mm dia.
(b)Concealed by chiselling or breaking brick wall/C.C/R.C.C and making good to the damages.
(ii)110mm dia
(iv) 75mm dia.
.Supplying fitting and fixing 87.5 degree P.V.C bend of(Supreme/Prince) or other ISI approved including joining fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified
(a)In exposed surfaces or in trenches
(ii) 110mm dia.
(b)Concealed by chiselling or breaking brick wall/C.C/R.C.C and making good to the damages.
(ii)110mm dia
(iii) 90mm dia.
Supplying fitting and fixing PVC 45 degree bend of (Supreme/Prince) or other ISI approved including joining fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified
(a)In exposed surfaces or in trenches
(i) 160mm dia
(ii)110mm dia
(b)Concealed by chiselling or breaking brick wall/C.C/R.C.C and making good to the damages.
(ii)110mm dia
(iii) 90mm dia.
Supplying fitting and fixing PVC plain single tee of (Supreme/Prince) or other ISI approved including joining fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified
(a)In exposed surfaces or in trenches
(i) 160mm dia
(ii)110mm dia
(b)Concealed by chiselling or breaking brick wall/C.C/R.C.C and making good to the damages.
(ii)110mm dia
(iii) 90mm dia.
Supplying fitting and fixing PVC single Y of (Supreme/Prince) or other ISI approved including joining fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified.
(a)In exposed surfaces or in trenches
(i) 160mm dia
(ii)110mm dia
(b)Concealed by chiselling or breaking brick wall/C.C/R.C.C and making good to the damages.
(ii)110mm dia
(iii) 90mm dia.
Supplying fitting and fixing PVC doubleY with door of (Supreme/Prince) or other ISI approved including joining fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified.
(a)In exposed surfaces or in trenches
(i)110mm dia
(b)Concealed by chiselling or breaking brick wall/C.C/R.C.C and making good to the damages.
(i)110mm dia
(ii)75mm dia
Supplying fitting and fixing PVC coupler of (Supreme/Prince) or other ISI approved including joining fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified.
(a)In exposed surfaces or in trenches
(i)110mm dia
(ii) 75mm dia
(b)Concealed by chiselling or breaking brick wall/C.C/R.C.C and making good to the damages.
(ii)110mm dia
(iv)75mm dia
Supplying fitting and fixing PVC reducer of (Supreme/Prince) or other ISI approved including joining fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified.
(a)In exposed surfaces or in trenches
(i) 160mm x 110 mm
(iv) 110 mm x 75mm
b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages.
(iv) 110 mm x 75mm
Supplying fitting and fixing PVC socket plug of (Supreme/Prince) or other ISI approved including joining fitting and fixing etc.in exposed surface or trenches as necessary complete at all levels including below G.L as directed and specified.
Supplying fitting and fixing PVC cleaning pipe of (Supreme/Prince) or other ISI approved including joining fitting and fixing etc.in exposed surface or trenches as necessary complete at all levels including below G.L as directed and specified.
COWEL
2Providing fitting and fixing PVC cowel of ISI make complete as directed and specified.
iv) 75 mm dia PVC cowel of ISI make.
GRATING
Providing fitting & fixing CI Grating to the floors complete as directed and specified
(a)110mm dia
TOP TILE STRAINER
Providing fitting & fixing (150 x 150)mm PVC top tile strainer complete as directed and specified CP Grating to the floors complete as directed and specified
PIPING
Providing and fixing CPVC pipe having thermal stability for hot and cold water supply including all CPVC plain and brass threated i/c fixing the pipe with clamp qt 1.0m spacing. Including joining pipes
( A) Exposed on wall
SUPREME/ PRINCE/ SFMC BRAND or other equvalent approved brand (High presure pipe Sch-40)
d) 25 mm dia
e)20 mm dia
( B) Concealed by chieselling or breaking brick wall/CC wall/RCC wall and making good to the damaged structure.
e)20mm dia
i)Using Tata(medium)
f)15mm dia
i)Using Tata(medium)
BIB COCK
Supplying fitting and fixing C.P bib cock 15mm dia of approved brand directed and specified.(G.I & C.P pipes will be measured separately)
Jaquare make
(iii)2-Way bib cock
STOP COCK
Supplying fitting and fixing brass stop-cock (heavy)of Sant make of approved size as mentioned below as directed and specified(G.I & C.P pipes will be measured and paid separately)
(i) Brass stop cock( heavy of sant make
a)15mm dia (angular)
HEALTH FAUCET
CERA MAKE :
CG 105A Health faucet brass body with wall hook and 1 metre SS braided rubber hase pipe .
FLUSH COCK.
Supplying fitting and fixing Chome plated(CP) Flush cock (heavy)of approved brand as directed and specified(G.I & C.P pipes will be measured and paid separately)
Jaquare brand
(a) continental / clarion
(i) Flush cock with flange 25mm with level plain knob
BASIN MIXER
Supplying, fitting and fixing Chrome Plated (C.P.) basin mixer complete as directed.
GROHE make Single - Lever Basin Mixer
a) Grohe BauFlow Single lever basin mixer with out popup Cat no-32851000
i) Central hole basin mixer Cat No.1100
SHOWER
Supplying fitting and fixing Chrome Plated (C.P.) shower 15mm dia. Of approved brand as directed and specified. (Pipes will be measured and paid separately)
Grohe make: Bau over head shower with arm 3 adjustable spreys with wall flenge Cat No- 27398000
(i) Shower arm light casted with wall flange
WALL MIXER
Supplying, fitting and fixing Chrome Plated (C.P.) wall mixer complete as directed.
iii) Wall mixer 3 in 1 system with provision for both telephonic shower and overhead shower complete with wall flange with 115mm long bend pipe Cat No.7281
VALVE
Supplying and fitting gun metal country pit valve(full way valve)I.S.I Make as specified and directed.
c) 25 mm dia
d) 20 mm dia.
e) 15 mm dia.
EXTERNAL WATER SUPPLY WORKS
WATER TANK
Supplying and placing plastic cylindrical vertical claused top (PCVC) tank of Sintex / Polycon / Patton make over the stagging with manhole cover with locking and cleaning arrangement including providing pads of size as required for inlet and outlet pipes
2000 Lt capacity
(a) Sintex make
Supplying fitting and fixing Pipes with all necessary fittings in exposed or in trenches including trenching and refilling the same etc complete as directed
B) uPVC pipe with uPVC fittings ( Using uPVC high pressure pipe) (Using SUPREME/ PRINCE/ SFMC/ FUSION brand pipe)
iv) 32 mm diameter
iii) 25mm diameter
MARRIAGE HALL
GROUND FLOOR
EARTHWORK
EXCAVATION :
Earth work in excavation for foundation trenches of walls, retaining walls, footings of columns, steps and septic tank etc including refilling ( return filling ) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc.and removal of surplus earth with all lead and lifts as directed and specified in the following classifications of soils including bailing out water where necessary as directed and specified.
(A) Up to a depth of 2.00 m below the existing ground level.
(b) In hard/ dense soil
PLINTH FILLING:
Earth/sand filling in plinth in layers not more than 150 mm thick including necessary carriage, watering,ramming etc. complete as directed and specified including payment of land compensation forest royalty, sales taxe and other duties and taxes as may be necessary.
(c) With river sand or silt (predominantly non plastic)by truck carriage including loading and unloading.
CEMENT CONCRETE WORKS
PLAIN CEMENT CONCRETE WORKS
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, wall, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where neccessary shall be measured and paid separately).
(a) In prop 1 cement : 3 sand : 6 coarse aggregate by volume
Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg.of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed.
REINFORCED CEMENT CONCRETE WORKS
Providing and laying plain/reinforced cement concrete works including dewatering if necessary,and curing complete but excluding cost of from work and reinforcment for reinforced cement concrete work (form work and reinforcement will be measured and paid separately)
Using mixture machine
(A)In sub-structure up to plinth level
Foundation, Fotting,columns with base,tie and plinth beam, grade beam, pilecap, base slab, retaining walls,walls,walls of septic tank, inspection pit and the like and other works not less than 100 mm thick up to plinth level.
P) Using admixture, plasticiser etc for air entraining, water reducing purposes including addition of agent for changing normal setting time of concrete as required.
b) M 20 grade concrete or Prorp.1:1.5:3
(B)In super structure from plinth level upto 1st floor level.
(ii)Columns, pillar, posts, struts, suspended floor, roof, landing, shelf, and support, balcony, lintel, sill band beam, girder, bressumer, cantilever, staircase(exceptspiral staircase and landing) including preparing the top surface and finishing of nosing.
P) Using admixture, plasticiser etc
b) M20 Grade concrete or prop 1:1.5:3
SHUTTERING /FORM WORKS
PLYBOARD SHUTTERING
Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in:
Columns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical face
Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties.
(a) For depth not exceeding 1.0M.
Flat Surfaces such as soffits of suspended floors, roofs, landings and the like.
Staircase with sloping or stepped soffits including risers and stringers but excluding Landing.
BRICK WORKS
Providing brick soiling in foundation and under floor with stone/best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering complete.
(a).Brick on flat soling.
(c).Stone soling of thickness 150mm.
Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed.
(I) In Sub-structure upto plinth level including dewatering if necessary
(b) In proportion 1:4.
100mm thick wall using Cellular Light Weight concrete block of Size 500x200x100mm conforming to IS-2185 Pt-3 or pt-4 in cement mortar of proportion 1: 5 including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding rod is to be provided at every 3 course interval and will be measured and paid separately)
FLOOR FINISHED
Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department)
a) Normal range Somany/ Orient/Nitco /Varmora/Jhonson Make
ii) Of size 600mmx600mm and above
MARBLE FLOORING AT VERANDAH, COMMON LOBBY, PASSAGE AND RECEPTION LOUNGE ETC.
18 mm thick Marble stone slab flooring of sizes 1200x1200 including treads and risers of steps, skirting, laid over 20 mm thick base of cement plaster 1:6 (1 cement : 6 coarse sand) laid and jointed with grey cement slurry including rubbing and polishing complete with marble slab of specified quality and shade at all levels.
(i) Dungri slab
ANTISKID TILES
Providing Antiskid Tiles of approved quality size, shape not less than 8mm on floor, skirting over a cement mortar bed 15mm thick of 1:3 (1 cement: 3 coarse sand) approved make fix with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/ white cement complete at all level as specified and directed.
VITRIFIED
iii)Executive range-2 (Sizes 600 mm x600mm and above)
c). Tuscan Series- Gres Lepato
B) ON WALLS
Providing polished vitrified wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/white cement slurry mixed with approved pigment to match shade of tilesc complete at all levels as specified and directed. (coloured pigment should be in conformity with colour of tiles and as approved and directed by the department).
iii) Of size300mmx600mm and above
15mm thick plastering of the interior surface of concrete water tanks with cement mortar in prop 1:4 admixed with modified Styrene Butadiene Rubber based polymer like Sika Latex of Sika India Ltd./Dr. Sealkit Masterbond Latex (Asian Chemicals)/Rheomix 141 of BASF @ 200gms per bag of cement as specified and directed by the department complete.
GRANITE FINISHED
Providing polished granite tiles of approved quality, size, shape and thickness not less than 18 mm on floors, skirtings, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Cement plastering to be measured and paid separately). (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department)
(i) With Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)
PLASTERING
10 mm thick Cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed.
b) In cement mortar 1:4
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed.
A) On rough side
b) In cement mortar 1:4
B) On fair side
b) In cement mortar 1:4
Extra over item no 6.2.1 to 6.2.3 for plastering on celling and soffits of stairs up to 1st floor level (instead of plastering on walls) including curing complete as directed.
Water Proofing Plastering
15mm thick plastering of the interior surface of concrete water tanks with cement mortar in prop 1:4 admixed with modified Styrene Butadiene Rubber based polymer like Sika Latex of Sika India Ltd./Dr. Sealkit Masterbond Latex (Asian Chemicals)/Rheomix 141 of BASF @ 200gms per bag of cement as specified and directed by the department complete.
Water Proofing treatment of toilet floor
Providing and applying over roof slab/ raft slab, two coats of waterproofing slurry like SikaTop Seal 107 of Sika India Ltd./Dr. Sealkit Flexbond AP 121 C (Asian Chemicals) ./ MASTERSEAL 550 @ 1.5kg per sq.m. per coat, by brush after proper surface preparation (surface preparation including thorough cleaning of surface to be measured and paid separately) as specified & directed by the Department complete.
WALL PUTTY
Providing two coats of acrylic water based wall putty/ wall filler of Asian Paints/ Berger/ Dulux over concrete/ cement plaster/ brick walls and ceilings both internal and external after removing all the loosely adhering material from the wall/ ceiling surface with the help of emery stone, putty blade or wire brush, moistening the wall with the help of sufficient quantity of clear water as specified and directed by the department.
WALL PAINTING
CEMENT PRIMER
a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
Wall painting (two coats) with acrylic emulsion paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth.
(a).Acrylic Emulsion Paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac)
EXTEROR PAINTING
Finishing old/ new wall with water proofing weather coat smooth anti-fungal exterior painting of Apex brand of Asian Paints and of required shade after cleaning and clearing the surface etc. including scaffolding complete as directed at all levels (two coats)
PAINTING ON STEEL AND OTHER METAL SURFACE
Applying primary coat over new steel and other metal surface over 100m in width or girth after preparing the surface by throughly cleaning oil,grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper.
Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter.
(i).Surfaces over 100mm in width or girth.
b). High gloss (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
PAINTING ON WOOD AND WOOD WOOD BASED SURFACES
Applying priming coat over new wood and wood based surfaces over 100mm in girth/width after and including preparing the surface by throughly cleaning oil, grease, dirt and other foreign matter, sand papering and knotting.
(a). With ready mixed paint , Wood primer (pink)
Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surfaces of all dirt, dust and other foreign matter sand papering and stopping.
(i).Surfaces over 100mm in width or girth.
b). High gloss (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
REINFORCEMENT
Supplying,fitting and fixing in position reinforcement bars conforming to relevant I.S Code for R.C.C work/R.B walling including straightening cleaning cutting and bending to proper shapes and length as per details supplying and binding with 20G annealed black wire and placing in position with proper blocks supports chairs spacers etc.complete.(No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they included in the rate.)(upto 1st fl level).
a) From Primary Producer: TATA/SAIL/Jindal steel/Shyam steel/RINL
(i) TMT Corrosion resistant steel (CRS) reiforcement bar
COLLAPSIBLE / ROLLING SHUTTERS
Providing and fixing in position collapsible M.S. shutters with vertical channels 20mmx10mmx2mm braced with flat iron diagonals 20mmx5mm size with top and bottom rails of T-iron 40mmx40mmx6mm with 38mm dia steel pulleys complete with bolts and nuts, locking arrangements, stoppers, handles including applying a priming coat of red lead paint.
GRILL WORKS
Providing,fitting and fixing M.S grill of required pattern for windows/clerestory windows/opening with M.S flats at required spacing in frame all round,square or round M.S bars with round headed bolts and nuts or screws.
I. Plain grill
(c) Fixed to Brickwork/P.C.C/R.C.C
CHOWKATH
Providing wood work in frame (chowkaths) of doors, windows, clerestory windows and other similar works wrought, framed and fixed in position in contact with C.C or brick masonry wall including supplying, fitting and fixing with M.S. hold fast (40mmx3mmx250mm) as per design embeded in cement concrete block in proportion 1:2:4 and with two coats of kiricide oiling to the timber faces in contact with C.C and masonry as directed and specified.
(a) With sal wood
Providing, fitting and fixing factory made Santro Flush door shutters having core & cross bands fabricated from seasoned 1st class timber, 25mm core battens, 2.5mm to 3.5mm uniformly thick cross bands, styles & rails made from hardwood timber of width not less than 50mm, fixed to the door frames (chowkath) with necessary hinges, screws, bolts etc. as specified and directed at all levels (Door fixtures and fittings to be measured and paid seperately.)
(a) 30mm thick
Providing, fitting and fixing PVC Door shutters of 37mm (single panel seamless finish) of Syntex make, at all levels made of extruded sections in the configuration of 'A'.The overall dimension is 37mm x 90mm, with usual process variation having a wall thickness of 2mm with a variation of +0.03mm provided with all plastic reinforcement to avoid rusting. The shutter frame is mitred and joined at the corners by means of stainless steel screws.The corners of the shutter frame are being reinforced by polymeric reinforcement of the size 125mm x 250mm and the lock rail is reinforced by 45 x18 x255 size reinforcement.
The lock rail is made of extruded hollow PVC section in the configuration of 'H' having wall thickness of 2mm with a variation of +0.03mm and effective dimension of 37mm x 105mm. The infill is made of multi-chambered hollow PVC extruded panel having an effective dimension of 762mm x 20mm or less as per requirement with usual process variation having a wall thickness of 1mm +0.03mm.The entire door shutter should be provided with S.S. screws at appropriate places for rust free quality. (Door fixtures and fittings to be measured and paid separately.)
Providing , fitting , and fixing Syntex PVC door frame made out of extruded PVC section in an over all size of 50mm x 60mm having multi chamber cross section with maximum wall thickness of 2mm, +0.3mm with special polymeric reinforcement having an over all size of 30mm x 25mm width,150mm length at hardware location. The corner joints shall be either mitre cut and welded or joined by means of concealed cleats with necessary screws fitting.
DOOR AND WINDOW FITTINGS
ALUMINIUM FITTINGS
Supplying,fitting,fixing anodised aluminium fittings of approved make,reasonably smooth,free from sharp edges and corners,flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc.complete.(anodised to bright natural matt &satin finished)
(a)Sliding door bolts
(ii)250mm x16mm
(b)Tower bolts
(iii)200mm x12mm
(c) Door handle
(iii)150mm
t) Door stopper with rubber stopper
RAILING
Providing and fixing Stainless Steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature(wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i.e. fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of engineer in charge.(For payment, only weight of stainless steel member is to be considered. No extra payment for fixing accessories such as nuts, bolts, fasteners etc. will be considered)
uPVC- Sliding Windows
Supplying and installing uPVC- Sliding Windows made out of Lead free, UV resistant green profile having "GREENLINE" mark of BIS standard uPVC multichambered sections of wall thickness 2.4mm with corners fusion welded, fully reinforced with Galvanized steel 1.5/2mm including interlock profile, glazing bead, grooving bead, brush seal, aluminum sliding track, stainless steel rollers, sealing wedge block, Espag, int handle, pop up handle, keeper, drain cap, fisher screws, packing pieces with all necessary stainlessness screws etc. complete as directed. The windows must be installed complete with all kinds of ironmongery including EPDM gaskets, bridging wedges and glass packers and with suitable water draining system. Application of silicon sealant from inside / outside of Dowcorning / GE or equivalent. With 5mm clear glass
(a) 2 Track Sliding Window with Flyscreen using uPVC section of sizes 88mm x 50 mm x 2.4mm thick wall for frame with inbuilt flyscreen track, 37mm x 61mm x 2.4mm thick wall for glass sash, 25mm x 49mm x 2.4mm thick wall for flyscreen sash and, Interlock: 43mm x 23mm (Glass Panel) (WINSTA KOMMERLING/ FENESTA/ ENCRAFT)
with Toughten glass
Supplying and installing uPVC- Casement Windows made out of Lead free, UV resistant green profile having "GREENLINE" mark of BIS standard uPVC multichambered sections with corners fusion welded, fully reinforced with Galvanized steel 1.5/2mm including glazing bead, folding gasket, glazing gasket, friction stay, Espag handle, Espag, keeper, drain cap, run up block, fisher screws, packing pieces with all stainless steel screws complete as directed. The windows must be installed complete with all kinds of ironmongery including EPDM gaskets,bridging wedges and glass packers and with suitable water draining system. Fittings ROTO / GQ or Equivalent. Application of Silicon sealant from Inside / Outside of Dowcorning / GE or equivalent complete as directed. (FENESTA/ENCRAFT/WINSTA KOMMERLING)
(d) Single leaf Top hung Window using uPVC section of minimum sizes 58mm x 57mm x 2.4mm thick wall for frame, 58mm x 68mm x 2.4mm thick wall for glass sash With 5mm clear float glass (WINSTA KOMMERLING/ FENESTA/ ENCRAFT)
with Toughten glass
ANTI-TERMITE TREATMENT
PRE-CONSTRUCTION ANTI-TERMITE TREATMENT
Pre- construction anti-termite treatment at the bottom of foundation pits and walls on either side up to a height of 300 mm from bottom of the excavation made for column plinth beam, wall, trenches etc. by applying the emulsion @ 5(five) litres per square meter of the surface area before starting construction work(supplying of neccessary tools and accessories by the contractor) as per the direction of the Department complete.
a) with aqueous emulsion having concentration 1:19 with chloropirophose solution(tricel or equivalent) and water, i.e. 1% solution.
Pre construction anti - termite treatment by applying in the entire levelled area after plinth filling and before laying floor by applying the emulsion @ 5 (five) litres per square meter of the surface to be spread with light rodding so as to ensure proper absorption by the filled up earth (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete.
a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
Pre construction anti - termite treatment by applying the soil along the external perimeter of the building (after construction completed) to a distance close to the plinth wall as specified and as directed by the deptt. up to a depth of 300mm making rod holes along the line @ 150mm apart to a depth of 300mm and applying emulsion @ 4.5 litres per running meter ensure moistening of the soil with emulsion (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete.
a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
PLINTH PROTECTION
Providing plinth protection with bricks flat laid in cement mortar 1: 4 and finished with 15mm thick cement plaster in prop. 1:2 with a floating coat of neat cement finish.
Providing drain with brick work in cement mortar in proportion 1:5 with half brick thick side walls and 100mm thick C.C (1:3:6) base over one brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shuttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified.
ii). 300mm wide and average 250mm deep with bed slope 1 in 150 with initial depth of 100mm.
R.C.C. PILING WORK.
MACHINE DRIVEN PILES
Providing cast in-situ machine driven reinforced cement concrete piles of required bore-diameter, bulb diameter, lengths and with reinforcement as per specifications and drawings including using of Bentonite solution. (Reinforcement to be measured and paid seperately as per item no. 21.4.1)
(A) SINGLE UNDER- REAMED PILE
UNIFORM PILE
(II) Concrete Grade M25
iii) Pile dia 400 mm
REINFORCEMENT
Supplying,fitting and fixing in position reinforcement bars conforming to relevent IS code, for reinforced cement concrete works in piles including straightening, cleaning ,cutting and bending to proper shapes and length as per specifications and drawings . The rings should be welded with vertical reinforcements as per specified IS codes of practice.(Inclusive of lap length, hook,chair, bend, anchor...etc)
(A) TMT bar made of Primary producer (From Primary producer)
DISMANTLING/ DEMOLISHING WORK.
Demolishing RCC/PCC pile head of different diameters carefully without disturbing the remaining portion of the pile including opening out of the pile head to be demolishing by excavating the earth upto required depth and clearing the debris as directed.
MISCELLANEOUS
Extra for using admixture & plasticiser
(a) RCC grade M20
iv) Pile Dia 400 mm
PILES TESTS
ROUTINE TESTS
Routine test for test loading to 1.5 times the specified safe working load including construction of any test pile cap and dismantling the same after completion of test. (Rate for Safe working Load)
Initial test for test loading to 2 times the specified safe working load including construction of any test pile cap and dismantling the same after completion of test. (Rate for Safe working Load)
Empty boring for specified diameter piles from ground level to cut-off level.
d) Pile Dia 400 mm
Extra for boring specified diameter pile in high sub-soil water level requiring use of drilling mud and extra cement. (iv) 400 mm dia
MARRIAGE HALL
FIRST FLOOR
REINFORCED CEMENT CONCRETE WORKS
Providing and laying plain/reinforced cement concrete works including dewatering if necessary,and curing complete but excluding cost of from work and reinforcment for reinforced cement concrete work ( form work and reinforcement will be measured and paid separately)
Using mixture machine
(B)In super structure from plinth level upto 1st floor level.
(ii)Columns, pillar, posts, struts, suspended floor, roof, landing, shelf, and support, balcony, lintel, sill band beam, girder, bressumer, cantilever, staircase(exceptspiral staircase and landing) including preparing the top surface and finishing of nosing.
P) Using admixture, plasticiser etc
b) M20 Grade concrete or prop 1:1.5:3
Extra for each subsequent floor or part thereof above 1st floor level
SHUTTERING /FORM WORKS
PLYBOARD SHUTTERING (FORMWORK)
Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in:
Columns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical face
Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties.
(a) For depth not exceeding 1.0M.
Flat Surfaces such as soffits of suspended floors, roofs, landings and the like.
Vertical surface such as walls (any thickness), parapet walls, partitions and the like including attached pilasters, butresses, plinth and string courses and the like.
Staircase with sloping or stepped soffits including risers and stringers but excluding Landing.
BRICK WORKS
100mm thick wall using Cellular Light Weight concrete block of Size 500x200x100mm conforming to IS-2185 Pt-3 or pt-4 in cement mortar of proportion 1: 5 including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding rod is to be provided at every 3 course interval and will be measured and paid separately)
Extra for each subsequent floor or part thereof above 1st floor level
FLOORING &FLOOR FINISH
Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department)
a) Normal range Somany/ Orient/Nitco /Varmora/Jhonson Make
ii) Of size 600mmx600mm and above
ANTISKID TILES
Providing Antiskid Tiles of approved quality size, shape not less than 8mm on floor, skirting over a cement mortar bed 15mm thick of 1:3 (1 cement: 3 coarse sand) approved make fix with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/ white cement complete at all level as specified and directed.
VITRIFIED
iii)Executive range-2 (Sizes 600 mm x600mm and above)
c). Tuscan Series- Gres Lepato
B) ON WALLS
Providing polished vitrified wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/white cement slurry mixed with approved pigment to match shade of tilesc complete at all levels as specified and directed. (coloured pigment should be in conformity with colour of tiles and as approved and directed by the department).
iii) Of size300mmx600mm and above
Water Proofing Plastering
15mm thick plastering of the interior surface of concrete water tanks with cement mortar in prop 1:4 admixed with modified Styrene Butadiene Rubber based polymer like Sika Latex of Sika India Ltd./Dr. Sealkit Masterbond Latex (Asian Chemicals)/Rheomix 141 of BASF @ 200gms per bag of cement as specified and directed by the department complete.
Water proofing treatment of toilet floor
Providing and applying over roof slab/ raft slab, two coats of waterproofing slurry like SikaTop Seal 107 of Sika India Ltd./Dr. Sealkit Flexbond AP 121 C (Asian Chemicals) ./ MASTERSEAL 550 @ 1.5kg per sq.m. per coat, by brush after proper surface preparation (surface preparation including thorough cleaning of surface to be measured and paid separately) as specified & directed by the Department complete.
GRANITE CLADDING
Providing polished granite tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 15 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey / Sika / Pedelite / Rouf) /white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (Cement plastering to be measured and paid separately). (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department). (Walls means both interior and exterior walls).
(i) With Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)
PLASTERING
10 mm thick Cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed.
b) In cement mortar 1:4
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed.
A) On rough side
b) In cement mortar 1:4
B) On fair side
b) In cement mortar 1:4
Extra over item no 6.2.1 to 6.2.3 for plastering on celling and soffits of stairs up to 1st floor level (instead of plastering on walls) including curing complete as directed.
Extra over item no 6.2.1 to 6.2.3 for exterior plastering over wall for every addl floor or part thereof beyond 1st floor level including curing complete as directed.
b) On two coat plaster
WALL PUTTY
Providing two coats of acrylic water based wall putty/ wall filler of Asian Paints/ Berger/ Dulux over concrete/ cement plaster/ brick walls and ceilings both internal and external after removing all the loosely adhering material from the wall/ ceiling surface with the help of emery stone, putty blade or wire brush, moistening the wall with the help of sufficient quantity of clear water as specified and directed by the department.
WALL PAINTING
CEMENT PRIMER
a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
INTERNAL PAINT
Wall painting (two coats) with acrylic emulsion paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth.
(a).Acrylic Emulsion Paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac)
EXTEROR PAINTING
SPECIAL WATHER PROOF COLOURING
Finishing old/ new wall with water proofing weather coat smooth anti-fungal exterior painting of Apex brand of Asian Paints and of required shade after cleaning and clearing the surface etc. including scaffolding complete as directed at all levels (two coats)
PAINTING ON STEEL AND OTHER METAL SURFACE
Applying primary coat over new steel and other metal surface over 100m in width or girth after preparing the surface by throughly cleaning oil,grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper.
Painting two coats (excluding priming coat) on new steel and other metal surface with alluminium paint of approved brand and manufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) and brushing to give an even shade including cleaning the surface of all dirt, dust and other foreign matter.
(a).Surfaces over 100mm in width or girth.
PAINTING ON WOOD AND WOOD WOOD BASED SURFACES
Applying priming coat over new wood and wood based surfaces over 100mm in girth/width after and including preparing the surface by throughly cleaning oil, grease, dirt and other foreign matter, sand papering and knotting.
(a). With ready mixed paint , Wood primer (pink)
Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surfaces of all dirt, dust and other foreign matter sand papering and stopping.
(i).Surfaces over 100mm in width or girth.
b). High gloss (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
REINFORCEMENT
Supplying,fitting and fixing in position reinforcement bars conforming to relevant I.S Code for R.C.C work/R.B walling including straightening cleaning cutting and bending to proper shapes and length as per details supplying and binding with 20G annealed black wire and placing in position with proper blocks supports chairs spacers etc.complete.(No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they included in the rate.)(upto 1st fl level).
a) From Primary Producer: TATA/SAIL/Jindal steel/Shyam steel/RINL
(i) TMT Corrosion resistant steel (CRS) reiforcement bar
Extra for each subsequent floor or part thereof above 1st floor level
GRILL WORKS
Providing,fitting and fixing M.S grill of required pattern for windows/clerestory windows/opening with M.S flats at required spacing in frame all round,square or round M.S bars with round headed bolts and nuts or screws.
I. Plain grill
© Fixed to Brickwork/P.C.C/R.C.C
CHOWKATH
Providing wood work in frame (chowkaths) of doors, windows, clerestory windows and other similar works wrought, framed and fixed in position in contact with C.C or brick masonry wall including supplying, fitting and fixing with M.S. hold fast (40mmx3mmx250mm) as per design embeded in cement concrete block in proportion 1:2:4 and with two coats of kiricide oiling to the timber faces in contact with C.C and masonry as directed and specified.
(a) With sal wood
Providing, fitting and fixing factory made Santro Flush door shutters having core & cross bands fabricated from seasoned 1st class timber, 25mm core battens, 2.5mm to 3.5mm uniformly thick cross bands, styles & rails made from hardwood timber of width not less than 50mm, fixed to the door frames (chowkath) with necessary hinges, screws, bolts etc. as specified and directed at all levels (Door fixtures and fittings to be measured and paid seperately.)
(a) 30mm thick
Providing, fitting and fixing 38mm Melamine faced pre-laminated cellular core Flush Door with 9mm/12mm thick high density exterior grade laminated particle board fixed to the internal wooden frame of Sal/Hollock wood with Polyurestene central core, fixed to the chowkath with necessary hinges, screws, bolts etc. as specified and directed at all levels.(Door fixtures to be measured and paid separately.)
(b)With Nepal Board-Exterior Grade (One side Decorative)
(ii) 12mm thick
uPVC- Sliding Windows
Supplying and installing uPVC- Sliding Windows made out of Lead free, UV resistant green profile having "GREENLINE" mark of BIS standard uPVC multichambered sections of wall thickness 2.4mm with corners fusion welded, fully reinforced with Galvanized steel 1.5/2mm including interlock profile, glazing bead, grooving bead, brush seal, aluminum sliding track, stainless steel rollers, sealing wedge block, Espag, int handle, pop up handle, keeper, drain cap, fisher screws, packing pieces with all necessary stainlessness screws etc. complete as directed. The windows must be installed complete with all kinds of ironmongery including EPDM gaskets, bridging wedges and glass packers and with suitable water draining system. Application of silicon sealant from inside / outside of Dowcorning / GE or equivalent. With 5mm clear glass
(a) 2 Track Sliding Window with Flyscreen using uPVC section of sizes 88mm x 50 mm x 2.4mm thick wall for frame with inbuilt flyscreen track, 37mm x 61mm x 2.4mm thick wall for glass sash, 25mm x 49mm x 2.4mm thick wall for flyscreen sash and, Interlock: 43mm x 23mm (Glass Panel) (WINSTA KOMMERLING/ FENESTA/ ENCRAFT)
with Toughten glass
Supplying and installing uPVC- Casement Windows made out of Lead free, UV resistant green profile having "GREENLINE" mark of BIS standard uPVC multichambered sections with corners fusion welded, fully reinforced with Galvanized steel 1.5/2mm including glazing bead, folding gasket, glazing gasket, friction stay, Espag handle, Espag, keeper, drain cap, run up block, fisher screws, packing pieces with all stainless steel screws complete as directed. The windows must be installed complete with all kinds of ironmongery including EPDM gaskets,bridging wedges and glass packers and with suitable water draining system. Fittings ROTO / GQ or Equivalent. Application of Silicon sealant from Inside / Outside of Dowcorning / GE or equivalent complete as directed. (FENESTA/ENCRAFT/WINSTA KOMMERLING)
(d) Single leaf Top hung Window using uPVC section of minimum sizes 58mm x 57mm x 2.4mm thick wall for frame, 58mm x 68mm x 2.4mm thick wall for glass sash With 5mm clear float glass (WINSTA KOMMERLING/ FENESTA/ ENCRAFT)
with Toughten glass
DOOR AND WINDOW FITTINGS
ALUMINIUM FITTINGS
Supplying,fitting,fixing anodised aluminium fittings of approved make,reasonably smooth,free from sharp edges and corners,flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc.complete.(anodised to bright natural matt &satin finished)
(a)Sliding door bolts
(ii)250mm x16mm
(b)Tower bolts
(iii)200mm x12mm
(c) Door handle
(iii)150mm
t) Door stopper with rubber stopper
RAILING
Providing and fixing Stainless Steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature(wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i.e. fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of engineer in charge.(For payment, only weight of stainless steel member is to be considered. No extra payment for fixing accessories such as nuts, bolts, fasteners etc. will be considered)
BARGE BOARD
Providing barge board of size 200mm x 20mm with 1st class local Hollock/ Bonsum timber including fitting and fixing with necessary wood screws etc. complete.
ROOFING SHEET
Providing Pre Painted Galvalume Sheet Roofing (PPGL) at all levels including fitting and fixing self drilling, self tapping screws complete (Roof trusses, purlins etc. to be measured and paid separately.)
TATA Blue scope/ Dyna roof / Wonder Roof or equivalent as directed by the Departement
(v) 0.60 mm thick
Providing Pre Painted Galvalume Sheet (PPGL) accessories ( Ridges / Valley / Gutter / Flashing) at all levels including fitting and fixing self drilling, self tapping screws complete. TATA Blue scope/ Dyna roof / Wonder Roof or equivalent as directed by the Departement
(v) 0.60 mm thick
ROOF TRUSS
Providing, fitting, hoisting and fixing of roof trusses fabricated out of combination of any two or all of the following sections (i) Square section (ii) Rectangular Hollow section of specification RSH/SHS and (iii) M.S. circular hlollow section of Grade 210 including purlins, bottom runners and providing M.S. cleat, M.S. angle base plank, bolts and nuts with red oxide primer including fitting bottom runner and cleat etc. for fixing ceiling joist as per design complete as directed as per specifications.
a) Using TATA make RHS/SHS of Grade 310 conforming to relevant I.S. code 4923 : 1997
FLY PROOF
Providing fly proof M.S. wire netting of I.S.gauge designation 85 with wire of dia 0.05 mm over hollock or other wood dressed frame including 1st class timber beading of 38mmx12 mm size chamfered including fitting, fixing with necessary wood screws etc.complete as directed (timber frame to be measured and paid separately).
ANGLES/FLATS/BOLTS AND NUTS
Supplying fitting and fixing M.S.angles, M.S. flat, M.S. bolts and nuts including painting with red lead paint one coat complete as directed.
b) M. S. Flats…….
FALSE CEILING
Supplying, fitting, fixing and painting where necessary (one coat primer and two coats of paint) M/ F suspended ceiling which includes G.I. perimeter channels of size 0.55mm thick (having one flange of 20mm and another flange of 30mm and a web of 27mm) along with perimeter of ceiling, screw fixed to brick wall/ partition with the help of nylon sleeves and screws, at 610mm c/c. Then suspending G.I. intermediate channels of size 45mm (0.9mm thick with two equal flanges of 15mm each) from the soffit at 1220mm c/c with ceiling angle of width 5mmx10mmx0.55mm thick fixed to soffit with G.I.cleat and steel expansion fasteners. Ceiling section of 0.55mm thickness having knurled web of 51.5mm and two equal flanges of 26mm each with lips of 10.5mm are then fixed to the intermediate channel with the help of connecting clip and in direction perpendicular to the intermediate channel at 457mm c/c, 9.5mm/ 12.5mm thick Gypboard.
False ceiling (Light Duty) with Moisture Resistant Board (conforming to IS:2095-1982) is then screw fixed to ceiling section with 25mm long drywall screws at 230mm c/c. Screw fixing is done mechanically either with screw driver or drilling machine with suitable attachment. Finally, the boards are to be jointed and finished so as to have a flush look which includes filling and finishing the tapered and square edges of the boards with jointing compound, joint paper tape and two coats of drywall topcoat suitable for Gypboard complete at all levels as specified and directed. (For light fittings, providing opening for doors, window, ventilators etc., cut out made with frame of perimeter channel supported suitably to be measured and paid separately as and where necessary).
12.5mm MRB
MARRIAGE HALL
SANITARY FITTINGS AND WATER SUPPLY WORKS
EUROPEAN TYPE WATER CLOSET
Providing fitting and fixing vitreous china pedestal type water closet (European type W.C pan 400mm high ) with seat and lead ,CP brass hinges and rubber buffers , CI/MS brackets , 40 mm dia flush band with fittings including painting of fittings and brackets, required. (Flushing Cistern to be paid separately)
C) Jaquar make
a) White
(vii) Wall mounted Closet Crystal (inclusive of seat cover and fittings) (Cat. No. 20047)
CONCEALED CISTERN
Supplying, fiting and fixing concealed cistern with all internal fittings with CI brackets including fitting and fixing standard size CP flush pipe, union clamps etc. compete as directed and specified (pipes will be measured separately)
A) Parryware make
(i) Rios with Chorme Push Plate (Cat no.8174/ Cat. No.C813726)
URINAL
Providing fitting and fixing vitreous china flat back type lipped front urinal basin with standard flush pipe and CP brass spreader and brass unions, etc. complete including painting of fittings and brackets, cutting and making good the walls & floors wherever required.
(C) Jaquar Make
(a) White
(iii) Large (Cat.No.URS-WHT-0703)
WASH BASIN
Providing vitreous china wash basin with CI/MS brackets ,C.P Brass chain with plug,PVC waste pipe including painting of fitting and brackets, cutting and making good the walls and slabs wherever required.( Pillar cock,stop cock, waste coupling are to be paid separately)
Table Top Basin
(C) Jaquar Make
(vi) JDBC (Cat. No.JDS-WHT-0547)
MIRROR
Providing fitting and fixing Decorative Mirror complete as directed and specified.
(A) Parryware Make
(a) Size 800mm x 600mm
SOAP TRAY,SOAP DISH,LIQUID SOAP DISPENSER AND LIQUID SOAP CONTAINER
Providing, fitting and fixing CP soap tray / soap dish complete as directed and specified.
(iii) Cera Make (Cat.No.CA-103)
TOWEL RAIL,TOWEL RACK & TOWEL RING
Providing fitting and fixing chrome plated (CP) towel rail of Jaquar make complete as directed and specified
(a) Jaquar make
(ii) Continental 600mm (Cat.No. ACN-1111N)
TOILET PAPER HOLDER
Providing, fitting and fixing Chrome Plated TOILET PAPER holder complete as directed and specified.
(a) Jaquar make
(ii) Continental toilet paper holder with flap (Cat.No. ACN-1153N)
WASTE COUPLING
Providing fitting and fixing chrome waste coupling (half thread HT and full thread FT)complete as directed and specified.
(a) Jaquar Make
(iii) Rupa 50mm (HT/ FT) (Cat.No.WS-0801)
BOTTLE TRAP
Providing, fitting and fixing chrome plate bottle trap complete as directed and specified.
(a) Jaquar make
(ii) Bottle trap (with internal partition) 32mm size with 300mm long wall connection pipe (Cat.No. ALD-769B)
PVC PIPES BENDS JUNCTIONS TEES ETC.
Supplying fitting and fixing PVC pipes of 6kgf/cmsq (Supreme/Prince)or other ISI approved including joining fitting and fixing with clamps etc.as necessary complete at all levels including below G.L as directed and specified.
(a)In exposed surfaces or in trenches
(i) 160mm dia.
(ii) 110mm dia.
(b)Concealed by chiselling or breaking brick wall/C.C/R.C.C and making good to the damages.
(ii)110mm dia
(iv) 75mm dia.
Supplying fitting and fixing 87.5 degree P.V.C bend of(Supreme/Prince) or other ISI approved including joining fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified
(a)In exposed surfaces or in trenches
(ii) 110mm dia.
(b)Concealed by chiselling or breaking brick wall/C.C/R.C.C and making good to the damages.
(ii)110mm dia
(iii) 90mm dia.
Supplying fitting and fixing PVC 45 degree bend of (Supreme/Prince) or other ISI approved including joining fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified
(a)In exposed surfaces or in trenches
(i) 160mm dia
(ii)110mm dia
(b)Concealed by chiselling or breaking brick wall/C.C/R.C.C and making good to the damages.
(ii)110mm dia
(iii) 90mm dia.
Supplying fitting and fixing PVC plain single tee of (Supreme/Prince) or other ISI approved including joining fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified
(a)In exposed surfaces or in trenches
(i) 160mm dia
(ii)110mm dia
(b)Concealed by chiselling or breaking brick wall/C.C/R.C.C and making good to the damages.
(ii)110mm dia
(iii) 90mm dia.
Supplying fitting and fixing PVC single Y of (Supreme/Prince) or other ISI approved including joining fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified.
(a)In exposed surfaces or in trenches
(i) 160mm dia
(ii)110mm dia
(b)Concealed by chiselling or breaking brick wall/C.C/R.C.C and making good to the damages.
(ii)110mm dia
(iii) 90mm dia.
Supplying fitting and fixing PVC doubleY with door of (Supreme/Prince) or other ISI approved including joining fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified.
(a)In exposed surfaces or in trenches
(i)110mm dia
(b)Concealed by chiselling or breaking brick wall/C.C/R.C.C and making good to the damages.
(i)110mm dia
(ii)75mm dia
Supplying fitting and fixing PVC coupler of (Supreme/Prince) or other ISI approved including joining fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified.
(a)In exposed surfaces or in trenches
(i)110mm dia
(ii) 75mm dia
(b)Concealed by chiselling or breaking brick wall/C.C/R.C.C and making good to the damages.
(ii)110mm dia
(iv)75mm dia
Supplying fitting and fixing PVC reducer of (Supreme/Prince) or other ISI approved including joining fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified.
(a)In exposed surfaces or in trenches
(i) 160mm x 110 mm
(iv) 110 mm x 75mm
b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages.
(iv) 110 mm x 75mm
Supplying fitting and fixing PVC socket plug of (Supreme/Prince) or other ISI approved including joining fitting and fixing etc.in exposed surface or trenches as necessary complete at all levels including below G.L as directed and specified.
Supplying fitting and fixing PVC cleaning pipe of (Supreme/Prince) or other ISI approved including joining fitting and fixing etc.in exposed surface or trenches as necessary complete at all levels including below G.L as directed and specified.
COWEL
2Providing fitting and fixing PVC cowel of ISI make complete as directed and specified.
iv) 75 mm dia PVC cowel of ISI make.
GRATING
Providing fitting & fixing CI Grating to the floors complete as directed and specified
(a)110mm dia
TOP TILE STRAINER
Providing fitting & fixing (150 x 150)mm PVC top tile strainer complete as directed and specified CP Grating to the floors complete as directed and specified
PIPING
Providing and fixing CPVC pipe having thermal stability for hot and cold water supply including all CPVC plain and brass threated i/c fixing the pipe with clamp qt 1.0m spacing. Including joining pipes
( A) Exposed on wall
SUPREME/ PRINCE/ SFMC BRAND or other equvalent approved brand (High presure pipe Sch-40)
d) 25 mm dia
e)20 mm dia
( B) Concealed by chieselling or breaking brick wall/CC wall/RCC wall and making good to the damaged structure.
e)20mm dia
i)Using Tata(medium)
f)15mm dia
i)Using Tata(medium)
BIB COCK
Supplying fitting and fixing C.P bib cock 15mm dia of approved brand directed and specified.(G.I & C.P pipes will be measured separately)
Jaquare make
(iii)2-Way bib cock
STOP COCK
Supplying fitting and fixing brass stop-cock (heavy)of Sant make of approved size as mentioned below as directed and specified(G.I & C.P pipes will be measured and paid separately)
(i) Brass stop cock( heavy of sant make
a)15mm dia (angular)
HEALTH FAUCET
CERA MAKE :
CG 105A Health faucet brass body with wall hook and 1 metre SS braided rubber hase pipe .
FLUSH COCK.
Supplying fitting and fixing Chome plated(CP) Flush cock (heavy)of approved brand as directed and specified(G.I & C.P pipes will be measured and paid separately)
Jaquare brand
(a) continental / clarion
(i) Flush cock with flange 25mm with level plain knob
BASIN MIXER
Supplying, fitting and fixing Chrome Plated (C.P.) basin mixer complete as directed.
GROHE make Single - Lever Basin Mixer
a) Grohe BauFlow Single lever basin mixer with out popup Cat no-32851000
i) Central hole basin mixer Cat No.1100
VALVE
Supplying and fitting gun metal country pit valve(full way valve)I.S.I Make as specified and directed.
c) 25 mm dia
d) 20 mm dia.
e) 15 mm dia.
EXTERNAL WATER SUPPLY WORKS
WATER TANK
Supplying and placing plastic cylindrical vertical claused top (PCVC) tank of Sintex / Polycon / Patton make over the stagging with manhole cover with locking and cleaning arrangement including providing pads of size as required for inlet and outlet pipes
2000 Lt capacity
(a) Sintex make
Supplying fitting and fixing Pipes with all necessary fittings in exposed or in trenches including trenching and refilling the same etc complete as directed
B) uPVC pipe with uPVC fittings ( Using uPVC high pressure pipe) (Using SUPREME/ PRINCE/ SFMC/ FUSION brand pipe)
iv) 32 mm diameter
iii) 25mm diameter
OUTDOOR TOILET BLOCK
GROUND FLOOR
EARTHWORK
EXCAVATION :
Earth work in excavation for foundation trenches of walls, retaining walls, footings of columns, steps and septic tank etc including refilling ( return filling ) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc.and removal of surplus earth with all lead and lifts as directed and specified in the following classifications of soils including bailing out water where necessary as directed and specified.
(A) Up to a depth of 2.00 m below the existing ground level.
(b) In hard/ dense soil
PLINTH FILLING:
Earth/sand filling in plinth in layers not more than 150 mm thick including necessary carriage, watering,ramming etc. complete as directed and specified including payment of land compensation forest royalty, sales taxe and other duties and taxes as may be necessary.
© With river sand or silt (predominantly non plastic)by truck carriage including loading and unloading.
CEMENT CONCRETE WORKS
PLAIN CEMENT CONCRETE WORKS
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, wall, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where neccessary shall be measured and paid separately).
(a) In prop 1 cement : 3 sand : 6 coarse aggregate by volume
REINFORCED CEMENT CONCRETE WORKS
Providing and laying plain/reinforced cement concrete works including dewatering if necessary,and curing complete but excluding cost of from work and reinforcment for reinforced cement concrete work ( form work and reinforcement will be measured and paid separately)
Using mixture machine
(A)In sub-structure up to plinth level
Foundation, Fotting,columns with base,tie and plinth beam, grade beam, pilecap, base slab, retaining walls,walls,walls of septic tank, inspection pit and the like and other works not less than 100 mm thick up to plinth level.
P) Using admixture, plasticiser etc for air entraining, water reducing purposes including addition of agent for changing normal setting time of concrete as required.
b) M 20 grade concrete or Prorp.1:1.5:3
(B)In super structure from plinth level upto 1st floor level.
(ii)Columns, pillar, posts, struts, suspended floor, roof, landing, shelf, and support, balcony, lintel, sill band beam, girder, bressumer, cantilever, staircase(exceptspiral staircase and landing) including preparing the top surface and finishing of nosing.
P) Using admixture, plasticiser etc
b) M20 Grade concrete or prop 1:1.5:3
SHUTTERING /FORM WORKS
PLYBOARD SHUTTERING
Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in:
Columns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical face
Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties.
(a) For depth not exceeding 1.0M.
Flat Surfaces such as soffits of suspended floors, roofs, landings and the like.
BRICK WORKS
Providing brick soiling in foundation and under floor with stone/best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering complete.
(a).Brick on flat soling.
(c).Stone soling of thickness 150mm.
Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed.
(I) In Sub-structure upto plinth level including dewatering if necessary
(b) In proportion 1:4.
100mm thick wall using Cellular Light Weight concrete block of Size 500x200x100mm conforming to IS-2185 Pt-3 or pt-4 in cement mortar of proportion 1: 5 including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding rod is to be provided at every 3 course interval and will be measured and paid separately)
ANTISKID TILES
Providing Antiskid Tiles of approved quality size, shape not less than 8mm on floor, skirting over a cement mortar bed 15mm thick of 1:3 (1 cement: 3 coarse sand) approved make fix with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/ white cement complete at all level as specified and directed.
VITRIFIED
iii)Executive range-2 (Sizes 600 mm x600mm and above)
c). Tuscan Series- Gres Lepato
B) ON WALLS
Providing polished vitrified wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/white cement slurry mixed with approved pigment to match shade of tilesc complete at all levels as specified and directed. (coloured pigment should be in conformity with colour of tiles and as approved and directed by the department).
iii) Of size300mmx600mm and above
PLASTERING
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed.
A) On rough side
b) In cement mortar 1:4
B) On fair side
b) In cement mortar 1:4
Extra over item no 6.2.1 to 6.2.3 for plastering on celling and soffits of stairs up to 1st floor level (instead of plastering on walls) including curing complete as directed.
Water Proofing Plastering
15mm thick plastering of the interior surface of concrete water tanks with cement mortar in prop 1:4 admixed with modified Styrene Butadiene Rubber based polymer like Sika Latex of Sika India Ltd./Dr. Sealkit Masterbond Latex (Asian Chemicals)/Rheomix 141 of BASF @ 200gms per bag of cement as specified and directed by the department complete.
Water Proofing treatment of toilet floor
Providing and applying over roof slab/ raft slab, two coats of waterproofing slurry like SikaTop Seal 107 of Sika India Ltd./Dr. Sealkit Flexbond AP 121 C (Asian Chemicals) ./ MASTERSEAL 550 @ 1.5kg per sq.m. per coat, by brush after proper surface preparation (surface preparation including thorough cleaning of surface to be measured and paid separately) as specified & directed by the Department complete.
WALL PUTTY
Providing two coats of acrylic water based wall putty/ wall filler of Asian Paints/ Berger/ Dulux over concrete/ cement plaster/ brick walls and ceilings both internal and external after removing all the loosely adhering material from the wall/ ceiling surface with the help of emery stone, putty blade or wire brush, moistening the wall with the help of sufficient quantity of clear water as specified and directed by the department.
WALL PAINTING
CEMENT PRIMER
a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
INTERIOR PAINTING
Wall painting (two coats) with acrylic emulsion paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth.
(a).Acrylic Emulsion Paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac)
EXTEROR PAINTING
Finishing old/ new wall with water proofing weather coat smooth anti-fungal exterior painting of Apex brand of Asian Paints and of required shade after cleaning and clearing the surface etc. including scaffolding complete as directed at all levels (two coats)
PAINTING ON STEEL AND OTHER METAL SURFACE
Applying primary coat over new steel and other metal surface over 100m in width or girth after preparing the surface by throughly cleaning oil,grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper.
Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter.
(i).Surfaces over 100mm in width or girth.
b). High gloss (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
PAINTING ON WOOD AND WOOD WOOD BASED SURFACES
Applying priming coat over new wood and wood based surfaces over 100mm in girth/width after and including preparing the surface by throughly cleaning oil, grease, dirt and other foreign matter, sand papering and knotting.
(a). With ready mixed paint , Wood primer (pink)
Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surfaces of all dirt, dust and other foreign matter sand papering and stopping.
(i).Surfaces over 100mm in width or girth.
b). High gloss (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
REINFORCEMENT
Supplying,fitting and fixing in position reinforcement bars conforming to relevant I.S Code for R.C.C work/R.B walling including straightening cleaning cutting and bending to proper shapes and length as per details supplying and binding with 20G annealed black wire and placing in position with proper blocks supports chairs spacers etc.complete.(No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they included in the rate.)(upto 1st fl level).
a) From Primary Producer: TATA/SAIL/Jindal steel/Shyam steel/RINL
(i) TMT Corrosion resistant steel (CRS) reiforcement bar
FALSE CEILING
Supplying, fitting, fixing and painting where necessary (one coat primer and two coats of paint) M/ F suspended ceiling which includes G.I. perimeter channels of size 0.55mm thick (having one flange of 20mm and another flange of 30mm and a web of 27mm) along with perimeter of ceiling, screw fixed to brick wall/ partition with the help of nylon sleeves and screws, at 610mm c/c. Then suspending G.I. intermediate channels of size 45mm (0.9mm thick with two equal flanges of 15mm each) from the soffit at 1220mm c/c with ceiling angle of width 5mmx10mmx0.55mm thick fixed to soffit with G.I.cleat and steel expansion fasteners. Ceiling section of 0.55mm thickness having knurled web of 51.5mm and two equal flanges of 26mm each with lips of 10.5mm are then fixed to the intermediate channel with the help of connecting clip and in direction perpendicular to the intermediate channel at 457mm c/c, 9.5mm/ 12.5mm thick Gypboard.
False ceiling (Light Duty) with Moisture Resistant Board (conforming to IS:2095-1982) is then screw fixed to ceiling section with 25mm long drywall screws at 230mm c/c. Screw fixing is done mechanically either with screw driver or drilling machine with suitable attachment. Finally, the boards are to be jointed and finished so as to have a flush look which includes filling and finishing the tapered and square edges of the boards with jointing compound, joint paper tape and two coats of drywall topcoat suitable for Gypboard complete at all levels as specified and directed. (For light fittings, providing opening for doors, window, ventilators etc., cut out made with frame of perimeter channel supported suitably to be measured and paid separately as and where necessary).
12.5mm MRB
GRILL WORKS
Providing,fitting and fixing M.S grill of required pattern for windows/clerestory windows/opening with M.S flats at required spacing in frame all round,square or round M.S bars with round headed bolts and nuts or screws.
I. Plain grill
© Fixed to Brickwork/P.C.C/R.C.C
CHOWKATH
Providing wood work in frame (chowkaths) of doors, windows, clerestory windows and other similar works wrought, framed and fixed in position in contact with C.C or brick masonry wall including supplying, fitting and fixing with M.S. hold fast (40mmx3mmx250mm) as per design embeded in cement concrete block in proportion 1:2:4 and with two coats of kiricide oiling to the timber faces in contact with C.C and masonry as directed and specified.
(a) With sal wood
Providing, fitting and fixing factory made Santro Flush door shutters having core & cross bands fabricated from seasoned 1st class timber, 25mm core battens, 2.5mm to 3.5mm uniformly thick cross bands, styles & rails made from hardwood timber of width not less than 50mm, fixed to the door frames (chowkath) with necessary hinges, screws, bolts etc. as specified and directed at all levels (Door fixtures and fittings to be measured and paid seperately.)
(a) 30mm thick
Providing, fitting and fixing PVC Door shutters of 37mm (single panel seamless finish) of Syntex make, at all levels made of extruded sections in the configuration of 'A'.The overall dimension is 37mm x 90mm, with usual process variation having a wall thickness of 2mm with a variation of +0.03mm provided with all plastic reinforcement to avoid rusting. The shutter frame is mitred and joined at the corners by means of stainless steel screws.The corners of the shutter frame are being reinforced by polymeric reinforcement of the size 125mm x 250mm and the lock rail is reinforced by 45 x18 x255 size reinforcement.
The lock rail is made of extruded hollow PVC section in the configuration of 'H' having wall thickness of 2mm with a variation of +0.03mm and effective dimension of 37mm x 105mm. The infill is made of multi-chambered hollow PVC extruded panel having an effective dimension of 762mm x 20mm or less as per requirement with usual process variation having a wall thickness of 1mm +0.03mm.The entire door shutter should be provided with S.S. screws at appropriate places for rust free quality. (Door fixtures and fittings to be measured and paid separately.)
Providing , fitting , and fixing Syntex PVC door frame made out of extruded PVC section in an over all size of 50mm x 60mm having multi chamber cross section with maximum wall thickness of 2mm, +0.3mm with special polymeric reinforcement having an over all size of 30mm x 25mm width,150mm length at hardware location. The corner joints shall be either mitre cut and welded or joined by means of concealed cleats with necessary screws fitting.
DOOR AND WINDOW FITTINGS
ALUMINIUM FITTINGS
Supplying,fitting,fixing anodised aluminium fittings of approved make,reasonably smooth,free from sharp edges and corners,flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc.complete.(anodised to bright natural matt &satin finished)
(a)Sliding door bolts
(ii)250mm x16mm
(b)Tower bolts
(iii)200mm x12mm
(c) Door handle
(iii)150mm
t) Door stopper with rubber stopper
uPVC Windows
Supplying and installing uPVC- Casement Windows made out of Lead free, UV resistant green profile having "GREENLINE" mark of BIS standard uPVC multichambered sections with corners fusion welded, fully reinforced with Galvanized steel 1.5/2mm including glazing bead, folding gasket, glazing gasket, friction stay, Espag handle, Espag, keeper, drain cap, run up block, fisher screws, packing pieces with all stainless steel screws complete as directed. The windows must be installed complete with all kinds of ironmongery including EPDM gaskets,bridging wedges and glass packers and with suitable water draining system. Fittings ROTO / GQ or Equivalent. Application of Silicon sealant from Inside / Outside of Dowcorning / GE or equivalent complete as directed. (FENESTA/ENCRAFT/WINSTA KOMMERLING)
(d) Single leaf Top hung Window using uPVC section of minimum sizes 58mm x 57mm x 2.4mm thick wall for frame, 58mm x 68mm x 2.4mm thick wall for glass sash With 5mm clear float glass (WINSTA KOMMERLING/ FENESTA/ ENCRAFT)
with Toughten glass
WATER PROOFING
(A) Supplying, mixing, laying and applying the following waterproofing systems over Raft slabs, Roof slabs, Terraces etc. including curing complete as specified and directed by the Department at all levels.: (i) 1mm thick single coat of Master Crete M-81 of Choksey Chemicals /Dr. Sealkit Sealcrete (Asian Chemicals)/ mixed with cement in the ratio 1:2 as a prime coat. (ii) 3mm thick Polymer modified mortar - Cement sand mortar (in prop 1:3) mixed with Master Crete M-81/Dr. Sealkit Sealcrete (Asian Chemicals)/RHEOMIX 131 of BASF @ 15% by weight of cement. (iii) 1mm thick coat of Master Crete M-81 /Dr. Sealkit Sealcrete (Asian Chemicals)/RHEOMIX 131 of BASF mixed with cement in the ratio 1:2 as final coat.
A) using Master Crete M-81 of Choksey Chemicals/Dr. Sealkit Sealcrete(Asian Chemicals)
ANTI-TERMITE TREATMENT
PRE-CONSTRUCTION ANTI-TERMITE TREATMENT
Pre- construction anti-termite treatment at the bottom of foundation pits and walls on either side up to a height of 300 mm from bottom of the excavation made for column plinth beam, wall, trenches etc. by applying the emulsion @ 5(five) litres per square meter of the surface area before starting construction work(supplying of neccessary tools and accessories by the contractor) as per the direction of the Department complete.
a) with aqueous emulsion having concentration 1:19 with chloropirophose solution(tricel or equivalent) and water, i.e. 1% solution.
Pre construction anti - termite treatment by applying in the entire levelled area after plinth filling and before laying floor by applying the emulsion @ 5 (five) litres per square meter of the surface to be spread with light rodding so as to ensure proper absorption by the filled up earth (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete.
a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
Pre construction anti - termite treatment by applying the soil along the external perimeter of the building (after construction completed) to a distance close to the plinth wall as specified and as directed by the deptt. up to a depth of 300mm making rod holes along the line @ 150mm apart to a depth of 300mm and applying emulsion @ 4.5 litres per running meter ensure moistening of the soil with emulsion (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete.
a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
PLINTH PROTECTION
Providing plinth protection with bricks flat laid in cement mortar 1: 4 and finished with 15mm thick cement plaster in prop. 1:2 with a floating coat of neat cement finish.
Providing drain with brick work in cement mortar in proportion 1:5 with half brick thick side walls and 100mm thick C.C (1:3:6) base over one brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shuttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified.
ii). 300mm wide and average 250mm deep with bed slope 1 in 150 with initial depth of 100mm.
BARGE BOARD
Providing barge board of size 200mm x 20mm with 1st class local Hollock/ Bonsum timber including fitting and fixing with necessary wood screws etc. complete.
ROOFING SHEET
Providing Pre Painted Galvalume Sheet Roofing (PPGL) at all levels including fitting and fixing self drilling, self tapping screws complete (Roof trusses, purlins etc. to be measured and paid separately.)
TATA Blue scope/ Dyna roof / Wonder Roof or equivalent as directed by the Departement
(v) 0.60 mm thick
Providing Pre Painted Galvalume Sheet (PPGL) accessories ( Ridges / Valley / Gutter / Flashing) at all levels including fitting and fixing self drilling, self tapping screws complete. TATA Blue scope/ Dyna roof / Wonder Roof or equivalent as directed by the Departement
(v) 0.60 mm thick
ROOF TRUSS
Providing, fitting, hoisting and fixing of roof trusses fabricated out of combination of any two or all of the following sections (i) Square section (ii) Rectangular Hollow section of specification RSH/SHS and (iii) M.S. circular hlollow section of Grade 210 including purlins, bottom runners and providing M.S. cleat, M.S. angle base plank, bolts and nuts with red oxide primer including fitting bottom runner and cleat etc. for fixing ceiling joist as per design complete as directed as per specifications.
a) Using TATA make RHS/SHS of Grade 310 conforming to relevant I.S. code 4923 : 1997
FLY PROOF
Providing fly proof M.S. wire netting of I.S.gauge designation 85 with wire of dia 0.05 mm over hollock or other wood dressed frame including 1st class timber beading of 38mmx12 mm size chamfered including fitting, fixing with necessary wood screws etc.complete as directed (timber frame to be measured and paid separately).
ANGLES/FLATS/BOLTS AND NUTS
Supplying fitting and fixing M.S.angles, M.S. flat, M.S. bolts and nuts including painting with red lead paint one coat complete as directed.
b) M. S. Flats…….
OUT DOOR TOILET BLOCK
SANITARY FITTINGS AND WATER SUPPLY WORKS
INDIAN TYPE WATER CLOSET
Providing fitting and fixing vitreous water closet squatting pan (Indian type W.C Orissa pattern) with all fittings and fixtures complete including cutting and making good to the walls and floors whereever required. (Flushing Cistern to be paid separately)
Indian type W.C Orissa pattern of size 580 x 440 mm
iii) Jaquar make
a) White
EUROPEAN TYPE WATER CLOSET
Providing fitting and fixing vitreous china pedestal type water closet (European type W.C pan 400mm high ) with seat and lead ,CP brass hinges and rubber buffers , CI/MS brackets , 40 mm dia flush band with fittings including painting of fittings and brackets, required. (Flushing Cistern to be paid separately)
C) Jaquar make
a) White
(vii) Wall mounted Closet Crystal (inclusive of seat cover and fittings) (Cat. No. 20047)
CONCEALED CISTERN
Supplying, fiting and fixing concealed cistern with all internal fittings with CI brackets including fitting and fixing standard size CP flush pipe, union clamps etc. compete as directed and specified (pipes will be measured separately)
A) Parryware make
(i) Rios with Chorme Push Plate (Cat no.8174/ Cat. No.C813726)
URINAL
Providing fitting and fixing vitreous china flat back type lipped front urinal basin with standard flush pipe and CP brass spreader and brass unions, etc. complete including painting of fittings and brackets, cutting and making good the walls & floors wherever required.
(C) Jaquar Make
(a) White
(iii) Large (Cat.No.URS-WHT-0703)
WASH BASIN
Providing vitreous china wash basin with CI/MS brackets ,C.P Brass chain with plug,PVC waste pipe including painting of fitting and brackets, cutting and making good the walls and slabs wherever required.( Pillar cock,stop cock, waste coupling are to be paid separately)
Table Top Basin
(C) Jaquar Make
(vi) JDBC (Cat. No.JDS-WHT-0547)
MIRROR
Providing fitting and fixing Decorative Mirror complete as directed and specified.
(A) Parryware Make
(a) Size 800mm x 600mm
SOAP TRAY,SOAP DISH,LIQUID SOAP DISPENSER AND LIQUID SOAP CONTAINER
Providing, fitting and fixing CP soap tray / soap dish complete as directed and specified.
(iii) Cera Make (Cat.No.CA-103)
TOWEL RAIL,TOWEL RACK & TOWEL RING
Providing fitting and fixing chrome plated (CP) towel rail of Jaquar make complete as directed and specified
(a) Jaquar make
(ii) Continental 600mm (Cat.No. ACN-1111N)
TOILET PAPER HOLDER
Providing, fitting and fixing Chrome Plated TOILET PAPER holder complete as directed and specified.
(a) Jaquar make
(ii) Continental toilet paper holder with flap (Cat.No. ACN-1153N)
WASTE COUPLING
Providing fitting and fixing chrome waste coupling (half thread HT and full thread FT)complete as directed and specified.
(a) Jaquar Make
(iii) Rupa 50mm (HT/ FT) (Cat.No.WS-0801)
BOTTLE TRAP
Providing, fitting and fixing chrome plate bottle trap complete as directed and specified.
(a) Jaquar make
(ii) Bottle trap (with internal partition) 32mm size with 300mm long wall connection pipe (Cat.No. ALD-769B)
PVC PIPES BENDS JUNCTIONS TEES ETC.
Supplying fitting and fixing PVC pipes of 6kgf/cmsq (Supreme/Prince)or other ISI approved including joining fitting and fixing with clamps etc.as necessary complete at all levels including below G.L as directed and specified.
(a)In exposed surfaces or in trenches
(i) 160mm dia.
(ii) 110mm dia.
(b)Concealed by chiselling or breaking brick wall/C.C/R.C.C and making good to the damages.
(ii)110mm dia
(iv) 75mm dia.
Supplying fitting and fixing 87.5 degree P.V.C bend of(Supreme/Prince) or other ISI approved including joining fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified
(a)In exposed surfaces or in trenches
(ii) 110mm dia.
(b)Concealed by chiselling or breaking brick wall/C.C/R.C.C and making good to the damages.
(ii)110mm dia
(iii) 90mm dia.
Supplying fitting and fixing PVC 45 degree bend of (Supreme/Prince) or other ISI approved including joining fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified
(a)In exposed surfaces or in trenches
(i) 160mm dia
(ii)110mm dia
(b)Concealed by chiselling or breaking brick wall/C.C/R.C.C and making good to the damages.
(ii)110mm dia
(iii) 90mm dia.
Supplying fitting and fixing PVC plain single tee of (Supreme/Prince) or other ISI approved including joining fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified
(a)In exposed surfaces or in trenches
(i) 160mm dia
(ii)110mm dia
(b)Concealed by chiselling or breaking brick wall/C.C/R.C.C and making good to the damages.
(ii)110mm dia
(iii) 90mm dia.
Supplying fitting and fixing PVC single Y of (Supreme/Prince) or other ISI approved including joining fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified.
(a)In exposed surfaces or in trenches
(i) 160mm dia
(ii)110mm dia
(b)Concealed by chiselling or breaking brick wall/C.C/R.C.C and making good to the damages.
(ii)110mm dia
(iii) 90mm dia.
Supplying fitting and fixing PVC doubleY with door of (Supreme/Prince) or other ISI approved including joining fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified.
(a)In exposed surfaces or in trenches
(i)110mm dia
(b)Concealed by chiselling or breaking brick wall/C.C/R.C.C and making good to the damages.
(i)110mm dia
(ii)75mm dia
Supplying fitting and fixing PVC coupler of (Supreme/Prince) or other ISI approved including joining fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified.
(a)In exposed surfaces or in trenches
(i)110mm dia
(ii) 75mm dia
(b)Concealed by chiselling or breaking brick wall/C.C/R.C.C and making good to the damages.
(ii)110mm dia
(iv)75mm dia
Supplying fitting and fixing PVC reducer of (Supreme/Prince) or other ISI approved including joining fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified.
(a)In exposed surfaces or in trenches
(i) 160mm x 110 mm
(iv) 110 mm x 75mm
b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages.
(iv) 110 mm x 75mm
Supplying fitting and fixing PVC socket plug of (Supreme/Prince) or other ISI approved including joining fitting and fixing etc.in exposed surface or trenches as necessary complete at all levels including below G.L as directed and specified.
Supplying fitting and fixing PVC cleaning pipe of (Supreme/Prince) or other ISI approved including joining fitting and fixing etc.in exposed surface or trenches as necessary complete at all levels including below G.L as directed and specified.
COWEL
2Providing fitting and fixing PVC cowel of ISI make complete as directed and specified.
iv) 75 mm dia PVC cowel of ISI make.
GRATING
Providing fitting & fixing CI Grating to the floors complete as directed and specified
(a)110mm dia
TOP TILE STRAINER
Providing fitting & fixing (150 x 150)mm PVC top tile strainer complete as directed and specified CP Grating to the floors complete as directed and specified
PIPING
Providing and fixing CPVC pipe having thermal stability for hot and cold water supply including all CPVC plain and brass threated i/c fixing the pipe with clamp qt 1.0m spacing. Including joining pipes
( A) Exposed on wall
SUPREME/ PRINCE/ SFMC BRAND or other equvalent approved brand (High presure pipe Sch-40)
d) 25 mm dia
e)20 mm dia
( B) Concealed by chieselling or breaking brick wall/CC wall/RCC wall and making good to the damaged structure.
e)20mm dia
i)Using Tata(medium)
f)15mm dia
i)Using Tata(medium)
BIB COCK
Supplying fitting and fixing C.P bib cock 15mm dia of approved brand directed and specified.(G.I & C.P pipes will be measured separately)
Jaquare make
(iii)2-Way bib cock
STOP COCK
Supplying fitting and fixing brass stop-cock (heavy)of Sant make of approved size as mentioned below as directed and specified(G.I & C.P pipes will be measured and paid separately)
(i) Brass stop cock( heavy of sant make
a)15mm dia (angular)
HEALTH FAUCET
CERA MAKE :
CG 105A Health faucet brass body with wall hook and 1 metre SS braided rubber hase pipe .
FLUSH COCK.
Supplying fitting and fixing Chome plated(CP) Flush cock (heavy)of approved brand as directed and specified(G.I & C.P pipes will be measured and paid separately)
Jaquare brand
(a) continental / clarion
(i) Flush cock with flange 25mm with level plain knob
BASIN MIXER
Supplying, fitting and fixing Chrome Plated (C.P.) basin mixer complete as directed.
GROHE make Single - Lever Basin Mixer
a) Grohe BauFlow Single lever basin mixer with out popup Cat no-32851000
i) Central hole basin mixer Cat No.1100
VALVE
Supplying and fitting gun metal country pit valve(full way valve)I.S.I Make as specified and directed.
c) 25 mm dia
d) 20 mm dia.
e) 15 mm dia.
EXTERNAL WATER SUPPLY WORKS
WATER TANK
Supplying and placing plastic cylindrical vertical claused top (PCVC) tank of Sintex / Polycon / Patton make over the stagging with manhole cover with locking and cleaning arrangement including providing pads of size as required for inlet and outlet pipes
2000 Lt capacity
(a) Sintex make
Supplying fitting and fixing Pipes with all necessary fittings in exposed or in trenches including trenching and refilling the same etc complete as directed
B) uPVC pipe with uPVC fittings ( Using uPVC high pressure pipe) (Using SUPREME/ PRINCE/ SFMC/ FUSION brand pipe)
iv) 32 mm diameter
iii) 25mm diameter
(A) PROPOSED ENTRANCE GATE
EARTHWORK
EXCAVATION :
Earth work in excavation for foundation trenches of walls, retaining walls, footings of columns, steps and septic tank etc including refilling ( return filling ) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc.and removal of surplus earth with all lead and lifts as directed and specified in the following classifications of soils including bailing out water where necessary as directed and specified.
(A) Up to a depth of 2.00 m below the existing ground level.
(b) In hard/ dense soil
CEMENT CONCRETE WORKS
PLAIN CEMENT CONCRETE WORKS
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, wall, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where neccessary shall be measured and paid separately).
(a) In prop 1 cement : 3 sand : 6 coarse aggregate by volume
REINFORCED CEMENT CONCRETE WORKS
Providing and laying plain/reinforced cement concrete works including dewatering if necessary,and curing complete but excluding cost of from work and reinforcment for reinforced cement concrete work ( form work and reinforcement will be measured and paid separately)
Using mixture machine
(A)In sub-structure up to plinth level
Foundation, Fotting,columns with base,tie and plinth beam, grade beam, pilecap, base slab, retaining walls,walls,walls of septic tank, inspection pit and the like and other works not less than 100 mm thick up to plinth level.
P) Using admixture, plasticiser etc for air entraining, water reducing purposes including addition of agent for changing normal setting time of concrete as required.
b) M 20 grade concrete or Prorp.1:1.5:3
(B)In super structure from plinth level upto 1st floor level.
(ii)Columns, pillar, posts, struts, suspended floor, roof, landing, shelf, and support, balcony, lintel, sill band beam, girder, bressumer, cantilever, staircase(exceptspiral staircase and landing) including preparing the top surface and finishing of nosing.
P) Using admixture, plasticiser etc
b) M20 Grade concrete or prop 1:1.5:3
SHUTTERING /FORM WORKS
PLYBOARD SHUTTERING
Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in:
Columns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical face
Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties.
(a) For depth not exceeding 1.0M.
Flat Surfaces such as soffits of suspended floors, roofs, landings and the like.
Vertical surface such as walls (any thickness), parapet walls, partitions and the like including attached pilasters, butresses, plinth and string courses and the like.
BRICK WORKS
Providing brick soiling in foundation and under floor with stone/best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering complete.
(a).Brick on flat soling.
FLOOR FINISHED
MARBLE FINISHED
18 mm thick Marble stone slab flooring of sizes 1200x1200 including treads and risers of steps, skirting, laid over 20 mm thick base of cement plaster 1:6 (1 cement : 6 coarse sand) laid and jointed with grey cement slurry including rubbing and polishing complete with marble slab of specified quality and shade at all levels.
(i) Dungri slab
PLASTERING
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed.
B) On fair side
b) In cement mortar 1:4
WALL PUTTY
Providing two coats of acrylic water based wall putty/ wall filler of Asian Paints/ Berger/ Dulux over concrete/ cement plaster/ brick walls and ceilings both internal and external after removing all the loosely adhering material from the wall/ ceiling surface with the help of emery stone, putty blade or wire brush, moistening the wall with the help of sufficient quantity of clear water as specified and directed by the department.
WALL PAINTING
CEMENT PRIMER
a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
EXTEROR PAINTING
Finishing old/ new wall with water proofing weather coat smooth anti-fungal exterior painting of Apex brand of Asian Paints and of required shade after cleaning and clearing the surface etc. including scaffolding complete as directed at all levels (two coats)
PAINTING ON STEEL AND OTHER METAL SURFACE
Applying primary coat over new steel and other metal surface over 100m in width or girth after preparing the surface by throughly cleaning oil,grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper.
Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter.
(i).Surfaces over 100mm in width or girth.
b). High gloss (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
REINFORCEMENT
Supplying,fitting and fixing in position reinforcement bars conforming to relevant I.S Code for R.C.C work/R.B walling including straightening cleaning cutting and bending to proper shapes and length as per details supplying and binding with 20G annealed black wire and placing in position with proper blocks supports chairs spacers etc.complete.(No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they included in the rate.)(upto 1st fl level).
a) From Primary Producer: TATA/SAIL/Jindal steel/Shyam steel/RINL
(i) TMT Corrosion resistant steel (CRS) reiforcement bar
IRON GATE
Supplying, fitting and fixing double leaf heavy duty iron gate, frame made from 50mm x 6mm M.S. flat iron with another horizontal flat at the middle, 20mm dia M.S bars at 200mm apart from bottom flat to top flat and 20 mm dia M.S. bars at 200mm apart from bottom flat to middle flat including drilling, welding etc. complete. All vertical bars are to be protruded at least 100mm above the middle and top flat is to be flattended and pointed as directed. Necessary locking arrangement on both faces, arrangement for temporary closing the gate and 2 nos.( minium) strong iron hinges of M.S bars and flat of same sizes on each leaf to be embeded in C.C brick pillars as necessary including a red oxide painting to all iron works as directed and specified. (Separate payment will be made for posts).
GRILL WORKS
Providing,fitting and fixing M.S grill of required pattern for windows/clerestory windows/opening with M.S flats at required spacing in frame all round,square or round M.S bars with round headed bolts and nuts or screws.
I. Plain grill
© Fixed to Brickwork/P.C.C/R.C.C
DOOR AND WINDOW FITTINGS
ALUMINIUM FITTINGS
Supplying,fitting,fixing anodised aluminium fittings of approved make,reasonably smooth,free from sharp edges and corners,flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc.complete.(anodised to bright natural matt &satin finished)
(a)Sliding door bolts
(ii)250mm x16mm
WATER PROOFING
Doing patch work in roof slab/ Raft slab wherever necessary by laying small portions of two component Polymer Modified Mortar Sika Top 122 as specified & directed by the Department complete after proper surface preparation (surface preparation including thorough cleaning of surface to be measured and paid separately).
(B) FRONT BOUNDARY WALL FAÇADE DEVELOPMENT
BRICK WORKS
100mm thick wall using Cellular Light Weight concrete block of Size 500x200x100mm conforming to IS-2185 Pt-3 or pt-4 in cement mortar of proportion 1: 5 including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding rod is to be provided at every 3 course interval and will be measured and paid separately)
PLASTERING
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed.
B) On fair side
b) In cement mortar 1:4
WALL PAINTING
CEMENT PRIMER
a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
WALL PUTTY
Providing two coats of acrylic water based wall putty/ wall filler of Asian Paints/ Berger/ Dulux over concrete/ cement plaster/ brick walls and ceilings both internal and external after removing all the loosely adhering material from the wall/ ceiling surface with the help of emery stone, putty blade or wire brush, moistening the wall with the help of sufficient quantity of clear water as specified and directed by the department.
EXTEROR PAINTING
Finishing old/new wall with water proofing weather coat smooth anti-fungal exterior painting of approved make of Dulux (ICI) paint of required shade after cleaning and clearing the surface etc. including scaffolding complete as directed at all levels (two coats)
Providing and applying Spectrum aggragate textured wall coating in the branded name of SPECTRUM with its all tools, plants and machineries and scaffolding etc. as per manufacturers guideline and specification of the product.
h)Spectrum Star Spray
OPEN AIR STAGE CUM SECURITY BOOTH
EARTHWORK
EXCAVATION :
Earth work in excavation for foundation trenches of walls, retaining walls, footings of columns, steps and septic tank etc including refilling ( return filling ) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc.and removal of surplus earth with all lead and lifts as directed and specified in the following classifications of soils including bailing out water where necessary as directed and specified.
(A) Up to a depth of 2.00 m below the existing ground level.
(b) In hard/ dense soil
PLINTH FILLING:
Earth/sand filling in plinth in layers not more than 150 mm thick including necessary carriage, watering,ramming etc. complete as directed and specified including payment of land compensation forest royalty, sales taxe and other duties and taxes as may be necessary.
(c) With river sand or silt (predominantly non plastic)by truck carriage including loading and unloading.
CEMENT CONCRETE WORKS
PLAIN CEMENT CONCRETE WORKS
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, wall, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where neccessary shall be measured and paid separately)
(a) In prop 1 cement : 3 sand : 6 coarse aggregate by volume
Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg.of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed.
REINFORCED CEMENT CONCRETE WORKS
Providing and laying plain/reinforced cement concrete works including dewatering if necessary,and curing complete but excluding cost of from work and reinforcment for reinforced cement concrete work ( form work and reinforcement will be measured and paid separately)
Using mixture machine
(A)In sub-structure up to plinth level
Foundation, Fotting,columns with base,tie and plinth beam, grade beam, pilecap, base slab, retaining walls,walls,walls of septic tank, inspection pit and the like and other works not less than 100 mm thick up to plinth level.
P) Using admixture, plasticiser etc for air entraining, water reducing purposes including addition of agent for changing normal setting time of concrete as required.
b) M 20 grade concrete or Prorp.1:1.5:3
(B)In super structure from plinth level upto 1st floor level.
(ii)Columns, pillar, posts, struts, suspended floor, roof, landing, shelf, and support, balcony, lintel, sill band beam, girder, bressumer, cantilever, staircase(exceptspiral staircase and landing) including preparing the top surface and finishing of nosing.
P) Using admixture, plasticiser etc
b) M20 Grade concrete or prop 1:1.5:3
SHUTTERING /FORM WORKS
PLYBOARD SHUTTERING
Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in:
Columns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical face
Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties.
(a) For depth not exceeding 1.0M.
Flat Surfaces such as soffits of suspended floors, roofs, landings and the like.
BRICK WORKS
Providing brick soiling in foundation and under floor with stone/best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering complete.
(a).Brick on flat soling.
Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed.
(I) In Sub-structure upto plinth level including dewatering if necessary
(b) In proportion 1:4.
(II) In superstructure above plinth level up to 1st floor level.
(b) In proportion 1:4.(1 cement:4 sand)
100mm thick wall using Cellular Light Weight concrete block of Size 500x200x100mm conforming to IS-2185 Pt-3 or pt-4 in cement mortar of proportion 1: 5 including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding rod is to be provided at every 3 course interval and will be measured and paid separately)
FLOOR FINISHED
Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department)
a) Normal range Somany/ Orient/Nitco /Varmora/Jhonson Make
ii) Of size 600mmx600mm and above
KOTA STONE SLAB / SAND STONE FLOORING
Kota stone slab of 18 mm thick in riser of steps, skirting, dado and pillars laid with 10mm thick cement plaster 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs including rubbing and polishing complete.
(2) 600mm x 900mm and above
ANTISKID TILES
Providing Antiskid Tiles of approved quality size, shape not less than 8mm on floor, skirting over a cement mortar bed 15mm thick of 1:3 (1 cement: 3 coarse sand) approved make fix with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/ white cement complete at all level as specified and directed.
(A) CERAMIC
i)Normal range (Sizes 300 mm x 300mm and above)
(a)Orient made: Galaxy Brown, Galaxy creama, Galaxy Pink, Galaxy Green, Pulsar Beige, Pulsar Blue, Pulsar Dove, Pulsar Pink, Burj Brown, Burj Green, Burj Slate
B) ON WALLS
Providing polished ceramic wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey / Sika / Pedelite / Rouf) /white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (Cement plastering to be measured and paid separately). (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department). (Walls means both interior and exterior walls).
a) Normal range Somany/ Orient/Nitco/Asian Make
ii) Of size 200mmx300mm and above
PLASTERING
10 mm thick Cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed.
b) In cement mortar 1:4
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed.
A) On rough side
b) In cement mortar 1:4
B) On fair side
b) In cement mortar 1:4
Extra over item no 6.2.1 to 6.2.3 for plastering on celling and soffits of stairs up to 1st floor level (instead of plastering on walls) including curing complete as directed.
Water Proofing Plastering
15mm thick plastering of the interior surface of concrete water tanks with cement mortar in prop 1:4 admixed with modified Styrene Butadiene Rubber based polymer like Sika Latex of Sika India Ltd./Dr. Sealkit Masterbond Latex (Asian Chemicals)/Rheomix 141 of BASF @ 200gms per bag of cement as specified and directed by the department complete.
Water Proofing treatment of toilet floor
Providing and applying over roof slab/ raft slab, two coats of waterproofing slurry like SikaTop Seal 107 of Sika India Ltd./Dr. Sealkit Flexbond AP 121 C (Asian Chemicals) ./ MASTERSEAL 550 @ 1.5kg per sq.m. per coat, by brush after proper surface preparation (surface preparation including thorough cleaning of surface to be measured and paid separately) as specified & directed by the Department complete.
WALL PUTTY
Providing two coats of acrylic water based wall putty/ wall filler of Asian Paints/ Berger/ Dulux over concrete/ cement plaster/ brick walls and ceilings both internal and external after removing all the loosely adhering material from the wall/ ceiling surface with the help of emery stone, putty blade or wire brush, moistening the wall with the help of sufficient quantity of clear water as specified and directed by the department.
WALL PAINTING
CEMENT PRIMER
a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
INTERIOR PAINTING
Wall painting (two coats) with acrylic emulsion paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth.
(a).Acrylic Emulsion Paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac)
EXTEROR PAINTING
WEATHER PROOFING
Finishing old/ new wall with water proofing weather coat smooth anti-fungal exterior painting of Apex brand of Asian Paints and of required shade after cleaning and clearing the surface etc. including scaffolding complete as directed at all levels (two coats)
PAINTING ON STEEL AND OTHER METAL SURFACE
Applying primary coat over new steel and other metal surface over 100m in width or girth after preparing the surface by throughly cleaning oil,grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper.
Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter.
(i).Surfaces over 100mm in width or girth.
b). High gloss (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
PAINTING ON WOOD AND WOOD WOOD BASED SURFACES
Applying priming coat over new wood and wood based surfaces over 100mm in girth/width after and including preparing the surface by throughly cleaning oil, grease, dirt and other foreign matter, sand papering and knotting.
(a). With ready mixed paint , Wood primer (pink)
Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surfaces of all dirt, dust and other foreign matter sand papering and stopping.
(i).Surfaces over 100mm in width or girth.
b). High gloss (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
REINFORCEMENT
Supplying,fitting and fixing in position reinforcement bars conforming to relevant I.S Code for R.C.C work/R.B walling including straightening cleaning cutting and bending to proper shapes and length as per details supplying and binding with 20G annealed black wire and placing in position with proper blocks supports chairs spacers etc.complete.(No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they included in the rate.)(upto 1st fl level).
a) From Primary Producer: TATA/SAIL/Jindal steel/Shyam steel/RINL
(i) TMT Corrosion resistant steel (CRS) reiforcement bar
GRILL WORKS
Providing,fitting and fixing M.S grill of required pattern for windows/clerestory windows/opening with M.S flats at required spacing in frame all round,square or round M.S bars with round headed bolts and nuts or screws.
I. Plain grill
© Fixed to Brickwork/P.C.C/R.C.C
CHOWKATH
Providing wood work in frame (chowkaths) of doors, windows, clerestory windows and other similar works wrought, framed and fixed in position in contact with C.C or brick masonry wall including supplying, fitting and fixing with M.S. hold fast (40mmx3mmx250mm) as per design embeded in cement concrete block in proportion 1:2:4 and with two coats of kiricide oiling to the timber faces in contact with C.C and masonry as directed and specified.
(a) With sal wood
Providing, fitting and fixing factory made Santro Flush door shutters having core & cross bands fabricated from seasoned 1st class timber, 25mm core battens, 2.5mm to 3.5mm uniformly thick cross bands, styles & rails made from hardwood timber of width not less than 50mm, fixed to the door frames (chowkath) with necessary hinges, screws, bolts etc. as specified and directed at all levels (Door fixtures and fittings to be measured and paid seperately.)
(a) 30mm thick
Providing, fitting and fixing PVC Door shutters of 37mm (single panel seamless finish) of Syntex make, at all levels made of extruded sections in the configuration of 'A'.The overall dimension is 37mm x 90mm, with usual process variation having a wall thickness of 2mm with a variation of +0.03mm provided with all plastic reinforcement to avoid rusting. The shutter frame is mitred and joined at the corners by means of stainless steel screws.The corners of the shutter frame are being reinforced by polymeric reinforcement of the size 125mm x 250mm and the lock rail is reinforced by 45 x18 x255 size reinforcement.
Providing, fitting and fixing factory made Santro Flush door shutters having core & cross bands fabricated from seasoned 1st class timber, 25mm core battens, 2.5mm to 3.5mm uniformly thick cross bands, styles & rails made from hardwood timber of width not less than 50mm, fixed to the door frames (chowkath) with necessary hinges, screws, bolts etc. as specified and directed at all levels (Door fixtures and fittings to be measured and paid seperately.)
(a) 30mm thick
The lock rail is made of extruded hollow PVC section in the configuration of 'H' having wall thickness of 2mm with a variation of +0.03mm and effective dimension of 37mm x 105mm. The infill is made of multi-chambered hollow PVC extruded panel having an effective dimension of 762mm x 20mm or less as per requirement with usual process variation having a wall thickness of 1mm +0.03mm.The entire door shutter should be provided with S.S. screws at appropriate places for rust free quality. (Door fixtures and fittings to be measured and paid separately.)
Providing , fitting , and fixing Syntex PVC door frame made out of extruded PVC section in an over all size of 50mm x 60mm having multi chamber cross section with maximum wall thickness of 2mm, +0.3mm with special polymeric reinforcement having an over all size of 30mm x 25mm width,150mm length at hardware location. The corner joints shall be either mitre cut and welded or joined by means of concealed cleats with necessary screws fitting.
DOOR AND WINDOW FITTINGS
ALUMINIUM FITTINGS
Supplying,fitting,fixing anodised aluminium fittings of approved make,reasonably smooth,free from sharp edges and corners,flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc.complete.(anodised to bright natural matt &satin finished)
(a)Sliding door bolts
(ii)250mm x16mm
(b)Tower bolts
(iii)200mm x12mm
(c) Door handle
(iii)150mm
t) Door stopper with rubber stopper
uPVC Windows
Supplying and installing uPVC- Sliding Windows made out of Lead free, UV resistant green profile having "GREENLINE" mark of BIS standard uPVC multichambered sections of wall thickness 2.4mm with corners fusion welded, fully reinforced with Galvanized steel 1.5/2mm including interlock profile, glazing bead, grooving bead, brush seal, aluminum sliding track, stainless steel rollers, sealing wedge block, Espag, int handle, pop up handle, keeper, drain cap, fisher screws, packing pieces with all necessary stainlessness screws etc. complete as directed. The windows must be installed complete with all kinds of ironmongery including EPDM gaskets, bridging wedges and glass packers and with suitable water draining system. Application of silicon sealant from inside / outside of Dowcorning / GE or equivalent. With 5mm clear glass
(a) 2 Track Sliding Window with Flyscreen using uPVC section of sizes 88mm x 50 mm x 2.4mm thick wall for frame with inbuilt flyscreen track, 37mm x 61mm x 2.4mm thick wall for glass sash, 25mm x 49mm x 2.4mm thick wall for flyscreen sash and, Interlock: 43mm x 23mm (Glass Panel) (WINSTA KOMMERLING/ FENESTA/ ENCRAFT)
with Toughten glass
Supplying and installing uPVC- Casement Windows made out of Lead free, UV resistant green profile having "GREENLINE" mark of BIS standard uPVC multichambered sections with corners fusion welded, fully reinforced with Galvanized steel 1.5/2mm including glazing bead, folding gasket, glazing gasket, friction stay, Espag handle, Espag, keeper, drain cap, run up block, fisher screws, packing pieces with all stainless steel screws complete as directed. The windows must be installed complete with all kinds of ironmongery including EPDM gaskets,bridging wedges and glass packers and with suitable water draining system. Fittings ROTO / GQ or Equivalent. Application of Silicon sealant from Inside / Outside of Dowcorning / GE or equivalent complete as directed. (FENESTA/ENCRAFT/WINSTA KOMMERLING)
(d) Single leaf Top hung Window using uPVC section of minimum sizes 58mm x 57mm x 2.4mm thick wall for frame, 58mm x 68mm x 2.4mm thick wall for glass sash With 5mm clear float glass (WINSTA KOMMERLING/ FENESTA/ ENCRAFT)
with Toughten glass
WATER PROOFING
(A) Supplying, mixing, laying and applying the following waterproofing systems over Raft slabs, Roof slabs, Terraces etc. including curing complete as specified and directed by the Department at all levels.: (i) 1mm thick single coat of Master Crete M-81 of Choksey Chemicals /Dr. Sealkit Sealcrete (Asian Chemicals)/ mixed with cement in the ratio 1:2 as a prime coat. (ii) 3mm thick Polymer modified mortar - Cement sand mortar (in prop 1:3) mixed with Master Crete M-81/Dr. Sealkit Sealcrete (Asian Chemicals)/RHEOMIX 131 of BASF @ 15% by weight of cement. (iii) 1mm thick coat of Master Crete M-81 /Dr. Sealkit Sealcrete (Asian Chemicals)/RHEOMIX 131 of BASF mixed with cement in the ratio 1:2 as final coat.
A) using Master Crete M-81 of Choksey Chemicals/Dr. Sealkit Sealcrete(Asian Chemicals)
ANTI-TERMITE TREATMENT
PRE-CONSTRUCTION ANTI-TERMITE TREATMENT
Pre- construction anti-termite treatment at the bottom of foundation pits and walls on either side up to a height of 300 mm from bottom of the excavation made for column plinth beam, wall, trenches etc. by applying the emulsion @ 5(five) litres per square meter of the surface area before starting construction work(supplying of neccessary tools and accessories by the contractor) as per the direction of the Department complete.
a) with aqueous emulsion having concentration 1:19 with chloropirophose solution(tricel or equivalent) and water, i.e. 1% solution.
Pre construction anti - termite treatment by applying in the entire levelled area after plinth filling and before laying floor by applying the emulsion @ 5 (five) litres per square meter of the surface to be spread with light rodding so as to ensure proper absorption by the filled up earth (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete.
a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
Pre construction anti - termite treatment by applying the soil along the external perimeter of the building (after construction completed) to a distance close to the plinth wall as specified and as directed by the deptt. up to a depth of 300mm making rod holes along the line @ 150mm apart to a depth of 300mm and applying emulsion @ 4.5 litres per running meter ensure moistening of the soil with emulsion (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete.
a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
PLINTH PROTECTION
Providing plinth protection with bricks flat laid in cement mortar 1: 4 and finished with 15mm thick cement plaster in prop. 1:2 with a floating coat of neat cement finish.
Providing drain with brick work in cement mortar in proportion 1:5 with half brick thick side walls and 100mm thick C.C (1:3:6) base over one brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shuttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified.
ii). 300mm wide and average 250mm deep with bed slope 1 in 150 with initial depth of 100mm.
SECURITY CUM OPEN AIR STAGE
SANITARY FITTINGS AND WATER SUPPLY WORKS
INDIAN TYPE WATER CLOSET
Providing fitting and fixing vitreous water closet squatting pan (Indian type W.C Orissa pattern) with all fittings and fixtures complete including cutting and making good to the walls and floors whereever required. (Flushing Cistern to be paid separately)
Indian type W.C Orissa pattern of size 580 x 440 mm
iii) Jaquar make
a) White
PVC FLUSHING CISTERN
Supplying, fiting and fixing PVC flushing cistern with all internal fittings with CI brackets including fitting and fixing standard size CP flush pipe, union clamps etc. compete as directed and specified (pipes will be measured separately)
ii) Hindware make
a) White
(i) Sleek+ PVC cistern
WASH BASIN
Providing vitreous china wash basin with CI/MS brackets ,C.P Brass chain with plug,PVC waste pipe including painting of fitting and brackets, cutting and making good the walls and slabs wherever required.( Pillar cock,stop cock, waste coupling are to be paid separately)
Corner Basin
(A) Parryware Make
(i) Corner 400 x 400 (Cat. No.C0408/55)
MIRROR
Providing fitting and fixing Mirror with plastic frame of size 500x400mm complete as directed and specified.
SOAP TRAY,SOAP DISH,LIQUID SOAP DISPENSER AND LIQUID SOAP CONTAINER
Providing, fitting and fixing CP soap tray / soap dish complete as directed and specified.
(a) Parryware Make
(i) Recess SP & SG dish (Cat.No. C9935)
TOWEL RAIL,TOWEL RACK & TOWEL RING
Providing fitting and fixing chrome plated (CP) towel rail of Jaquar make complete as directed and specified
(b) Sona make
(i) Towel rail Diplomat 300mm long (Cat.No.TR-0605)
WASTE COUPLING
Providing fitting and fixing chrome waste coupling (half thread HT and full thread FT)complete as directed and specified.
(a) Jaquar Make
(iii) Rupa 50mm (HT/ FT) (Cat.No.WS-0801)
BOTTLE TRAP
Providing, fitting and fixing chrome plate bottle trap complete as directed and specified.
(a) Jaquar make
(i) Bottle trap (with internal partition) 32mm size with 250mm long wall connection pipe (Cat.No. ALD-769)
PVC PIPES BENDS JUNCTIONS TEES ETC.
Supplying fitting and fixing PVC pipes of 6kgf/cmsq (Supreme/Prince)or other ISI approved including joining fitting and fixing with clamps etc.as necessary complete at all levels including below G.L as directed and specified.
(a)In exposed surfaces or in trenches
(i) 160mm dia.
(ii) 110mm dia.
(b)Concealed by chiselling or breaking brick wall/C.C/R.C.C and making good to the damages.
(ii)110mm dia
(iv) 75mm dia.
Supplying fitting and fixing 87.5 degree P.V.C bend of(Supreme/Prince) or other ISI approved including joining fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified
(a)In exposed surfaces or in trenches
(ii) 110mm dia.
(b)Concealed by chiselling or breaking brick wall/C.C/R.C.C and making good to the damages.
(ii)110mm dia
(iii) 90mm dia.
Supplying fitting and fixing PVC 45 degree bend of (Supreme/Prince) or other ISI approved including joining fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified
(a)In exposed surfaces or in trenches
(i) 160mm dia
(ii)110mm dia
(b)Concealed by chiselling or breaking brick wall/C.C/R.C.C and making good to the damages.
(ii)110mm dia
(iii) 90mm dia.
Supplying fitting and fixing PVC doubleY with door of (Supreme/Prince) or other ISI approved including joining fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified.
(a)In exposed surfaces or in trenches
(i)110mm dia
(b)Concealed by chiselling or breaking brick wall/C.C/R.C.C and making good to the damages.
(i)110mm dia
(ii)75mm dia
Supplying fitting and fixing PVC coupler of (Supreme/Prince) or other ISI approved including joining fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified.
(a)In exposed surfaces or in trenches
(i)110mm dia
(ii) 75mm dia
(b)Concealed by chiselling or breaking brick wall/C.C/R.C.C and making good to the damages.
(ii)110mm dia
(iv)75mm dia
Supplying fitting and fixing PVC reducer of (Supreme/Prince) or other ISI approved including joining fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified.
(a)In exposed surfaces or in trenches
(i) 160mm x 110 mm
(iv) 110 mm x 75mm
b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages.
(iv) 110 mm x 75mm
Supplying fitting and fixing PVC socket plug of (Supreme/Prince) or other ISI approved including joining fitting and fixing etc.in exposed surface or trenches as necessary complete at all levels including below G.L as directed and specified.
Supplying fitting and fixing PVC cleaning pipe of (Supreme/Prince) or other ISI approved including joining fitting and fixing etc.in exposed surface or trenches as necessary complete at all levels including below G.L as directed and specified.
COWEL
2Providing fitting and fixing PVC cowel of ISI make complete as directed and specified.
iv) 75 mm dia PVC cowel of ISI make.
GRATING
Providing fitting & fixing CI Grating to the floors complete as directed and specified
(a)110mm dia
TOP TILE STRAINER
Providing fitting & fixing (150 x 150)mm PVC top tile strainer complete as directed and specified CP Grating to the floors complete as directed and specified
PIPING
Providing and fixing CPVC pipe having thermal stability for hot and cold water supply including all CPVC plain and brass threated i/c fixing the pipe with clamp qt 1.0m spacing. Including joining pipes
( A) Exposed on wall
SUPREME/ PRINCE/ SFMC BRAND or other equvalent approved brand (High presure pipe Sch-40)
d) 25 mm dia
e)20 mm dia
( B) Concealed by chieselling or breaking brick wall/CC wall/RCC wall and making good to the damaged structure.
e)20mm dia
i)Using Tata(medium)
f)15mm dia
i)Using Tata(medium)
BIB COCK
Supplying fitting and fixing C.P bib cock 15mm dia of approved brand directed and specified.(G.I & C.P pipes will be measured separately)
Jaquare make
(iii)2-Way bib cock
STOP COCK
Supplying fitting and fixing brass stop-cock (heavy)of Sant make of approved size as mentioned below as directed and specified(G.I & C.P pipes will be measured and paid separately)
(i) Brass stop cock( heavy of sant make
a)15mm dia (angular)
HEALTH FAUCET
CERA MAKE :
CG 105A Health faucet brass body with wall hook and 1 metre SS braided rubber hase pipe .
FLUSH COCK.
Supplying fitting and fixing Chome plated(CP) Flush cock (heavy)of approved brand as directed and specified(G.I & C.P pipes will be measured and paid separately)
Jaquare brand
(a) continental / clarion
(i) Flush cock with flange 25mm with level plain knob
VALVE
Supplying and fitting gun metal country pit valve(full way valve)I.S.I Make as specified and directed.
c) 25 mm dia
d) 20 mm dia.
e) 15 mm dia.
EXTERNAL WATER SUPPLY WORKS
WATER TANK
Supplying and placing plastic cylindrical vertical claused top (PCVC) tank of Sintex / Polycon / Patton make over the stagging with manhole cover with locking and cleaning arrangement including providing pads of size as required for inlet and outlet pipes
500 litre capacity
(a) Sintex make
Supplying fitting and fixing Pipes with all necessary fittings in exposed or in trenches including trenching and refilling the same etc complete as directed
B) uPVC pipe with uPVC fittings ( Using uPVC high pressure pipe) (Using SUPREME/ PRINCE/ SFMC/ FUSION brand pipe)
iii) 25mm diameter
SEPTIC TANK
Supplying and placing ferrocement septic tanks of rectangular shape in to pit with manhole cover with cleaning arrangement over single brick flat soling and 75mm 1:3:6 P.C.C. Baffle wall, inlet and outlet etc are provided at suitable points complete as directed.
10 Users
ELECTRICAL PANEL ROOM
EARTHWORK
EXCAVATION :
Earth work in excavation for foundation trenches of walls, retaining walls, footings of columns, steps and septic tank etc including refilling ( return filling ) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc.and removal of surplus earth with all lead and lifts as directed and specified in the following classifications of soils including bailing out water where necessary as directed and specified.
(A) Up to a depth of 2.00 m below the existing ground level.
(b) In hard/ dense soil
PLINTH FILLING:
Earth/sand filling in plinth in layers not more than 150 mm thick including necessary carriage, watering,ramming etc. complete as directed and specified including payment of land compensation forest royalty, sales taxe and other duties and taxes as may be necessary.
© With river sand or silt (predominantly non plastic)by truck carriage including loading and unloading.
CEMENT CONCRETE WORKS
PLAIN CEMENT CONCRETE WORKS
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, wall, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where neccessary shall be measured and paid separately).
(a) In prop 1 cement : 3 sand : 6 coarse aggregate by volume
Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg.of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed.
REINFORCED CEMENT CONCRETE WORKS
Providing and laying plain/reinforced cement concrete works including dewatering if necessary,and curing complete but excluding cost of from work and reinforcment for reinforced cement concrete work ( form work and reinforcement will be measured and paid separately)
Using mixture machine
(A)In sub-structure up to plinth level
Foundation, Fotting,columns with base,tie and plinth beam, grade beam, pilecap, base slab, retaining walls,walls,walls of septic tank, inspection pit and the like and other works not less than 100 mm thick up to plinth level.
P) Using admixture, plasticiser etc for air entraining, water reducing purposes including addition of agent for changing normal setting time of concrete as required.
b) M 20 grade concrete or Prorp.1:1.5:3
(B)In super structure from plinth level upto 1st floor level.
(ii)Columns, pillar, posts, struts, suspended floor, roof, landing, shelf, and support, balcony, lintel, sill band beam, girder, bressumer, cantilever, staircase(exceptspiral staircase and landing) including preparing the top surface and finishing of nosing.
P) Using admixture, plasticiser etc
b) M20 Grade concrete or prop 1:1.5:3
SHUTTERING /FORM WORKS
PLYBOARD SHUTTERING
Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in:
Columns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical face
Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties.
(a) For depth not exceeding 1.0M.
Flat Surfaces such as soffits of suspended floors, roofs, landings and the like.
BRICK WORKS
Providing brick soiling in foundation and under floor with stone/best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering complete.
(a).Brick on flat soling.
(c).Stone soling of thickness 150mm.
Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed.
(I) In Sub-structure upto plinth level including dewatering if necessary
(b) In proportion 1:4.
(II) In superstructure above plinth level up to 1st floor level.
100mm thick wall using Cellular Light Weight concrete block of Size 500x200x100mm conforming to IS-2185 Pt-3 or pt-4 in cement mortar of proportion 1: 5 including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding rod is to be provided at every 3 course interval and will be measured and paid separately)
FLOOR FINISHED
Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department)
a) Normal range Somany/ Orient/Nitco /Varmora/Jhonson Make
ii) Of size 600mmx600mm and above
PLASTERING
10 mm thick Cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed.
b) In cement mortar 1:4
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed.
A) On rough side
b) In cement mortar 1:4
B) On fair side
b) In cement mortar 1:4
Extra over item no 6.2.1 to 6.2.3 for plastering on celling and soffits of stairs up to 1st floor level (instead of plastering on walls) including curing complete as directed.
WALL PUTTY
Providing two coats of acrylic water based wall putty/ wall filler of Asian Paints/ Berger/ Dulux over concrete/ cement plaster/ brick walls and ceilings both internal and external after removing all the loosely adhering material from the wall/ ceiling surface with the help of emery stone, putty blade or wire brush, moistening the wall with the help of sufficient quantity of clear water as specified and directed by the department.
WALL PAINTING
CEMENT PRIMER
a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
INTERIOR PAINTING
Wall painting (two coats) with acrylic emulsion paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth.
(a).Acrylic Emulsion Paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac)
EXTEROR PAINTING
Finishing old/ new wall with water proofing weather coat smooth anti-fungal exterior painting of Apex brand of Asian Paints and of required shade after cleaning and clearing the surface etc. including scaffolding complete as directed at all levels (two coats)
PAINTING ON STEEL AND OTHER METAL SURFACE
Applying primary coat over new steel and other metal surface over 100m in width or girth after preparing the surface by throughly cleaning oil,grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper.
Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter.
(i).Surfaces over 100mm in width or girth.
b). High gloss (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
PAINTING ON WOOD AND WOOD WOOD BASED SURFACES
Applying priming coat over new wood and wood based surfaces over 100mm in girth/width after and including preparing the surface by throughly cleaning oil, grease, dirt and other foreign matter, sand papering and knotting.
(a). With ready mixed paint , Wood primer (pink)
Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surfaces of all dirt, dust and other foreign matter sand papering and stopping.
(i).Surfaces over 100mm in width or girth.
b). High gloss (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
REINFORCEMENT
Supplying,fitting and fixing in position reinforcement bars conforming to relevant I.S Code for R.C.C work/R.B walling including straightening cleaning cutting and bending to proper shapes and length as per details supplying and binding with 20G annealed black wire and placing in position with proper blocks supports chairs spacers etc.complete.(No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they included in the rate.)(upto 1st fl level).
a) From Primary Producer: TATA/SAIL/Jindal steel/Shyam steel/RINL
(i) TMT Corrosion resistant steel (CRS) reiforcement bar
GRILL WORKS
Providing,fitting and fixing M.S grill of required pattern for windows/clerestory windows/opening with M.S flats at required spacing in frame all round,square or round M.S bars with round headed bolts and nuts or screws.
I. Plain grill
© Fixed to Brickwork/P.C.C/R.C.C
CHOWKATH
Providing wood work in frame (chowkaths) of doors, windows, clerestory windows and other similar works wrought, framed and fixed in position in contact with C.C or brick masonry wall including supplying, fitting and fixing with M.S. hold fast (40mmx3mmx250mm) as per design embeded in cement concrete block in proportion 1:2:4 and with two coats of kiricide oiling to the timber faces in contact with C.C and masonry as directed and specified.
(a) With sal wood
Providing, fitting and fixing factory made Santro Flush door shutters having core & cross bands fabricated from seasoned 1st class timber, 25mm core battens, 2.5mm to 3.5mm uniformly thick cross bands, styles & rails made from hardwood timber of width not less than 50mm, fixed to the door frames (chowkath) with necessary hinges, screws, bolts etc. as specified and directed at all levels (Door fixtures and fittings to be measured and paid seperately.)
(a) 30mm thick
DOOR AND WINDOW FITTINGS
ALUMINIUM FITTINGS
Supplying,fitting,fixing anodised aluminium fittings of approved make,reasonably smooth,free from sharp edges and corners,flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc.complete.(anodised to bright natural matt &satin finished)
(a)Sliding door bolts
(ii)250mm x16mm
(b)Tower bolts
(iii)200mm x12mm
(c) Door handle
(iii)150mm
t) Door stopper with rubber stopper
uPVC Windows
Supplying and installing uPVC- Sliding Windows made out of Lead free, UV resistant green profile having "GREENLINE" mark of BIS standard uPVC multichambered sections of wall thickness 2.4mm with corners fusion welded, fully reinforced with Galvanized steel 1.5/2mm including interlock profile, glazing bead, grooving bead, brush seal, aluminum sliding track, stainless steel rollers, sealing wedge block, Espag, int handle, pop up handle, keeper, drain cap, fisher screws, packing pieces with all necessary stainlessness screws etc. complete as directed. The windows must be installed complete with all kinds of ironmongery including EPDM gaskets, bridging wedges and glass packers and with suitable water draining system. Application of silicon sealant from inside / outside of Dowcorning / GE or equivalent. With 5mm clear glass
(a) 2 Track Sliding Window with Flyscreen using uPVC section of sizes 88mm x 50 mm x 2.4mm thick wall for frame with inbuilt flyscreen track, 37mm x 61mm x 2.4mm thick wall for glass sash, 25mm x 49mm x 2.4mm thick wall for flyscreen sash and, Interlock: 43mm x 23mm (Glass Panel) (WINSTA KOMMERLING/ FENESTA/ ENCRAFT)
(i) 2-Panel with 5mm clear float glass
WATER PROOFING
(A) Supplying, mixing, laying and applying the following waterproofing systems over Raft slabs, Roof slabs, Terraces etc. including curing complete as specified and directed by the Department at all levels.: (i) 1mm thick single coat of Master Crete M-81 of Choksey Chemicals /Dr. Sealkit Sealcrete (Asian Chemicals)/ mixed with cement in the ratio 1:2 as a prime coat. (ii) 3mm thick Polymer modified mortar - Cement sand mortar (in prop 1:3) mixed with Master Crete M-81/Dr. Sealkit Sealcrete (Asian Chemicals)/RHEOMIX 131 of BASF @ 15% by weight of cement. (iii) 1mm thick coat of Master Crete M-81 /Dr. Sealkit Sealcrete (Asian Chemicals)/RHEOMIX 131 of BASF mixed with cement in the ratio 1:2 as final coat.
A) using Master Crete M-81 of Choksey Chemicals/Dr. Sealkit Sealcrete(Asian Chemicals)
ANTI-TERMITE TREATMENT
PRE-CONSTRUCTION ANTI-TERMITE TREATMENT
Pre- construction anti-termite treatment at the bottom of foundation pits and walls on either side up to a height of 300 mm from bottom of the excavation made for column plinth beam, wall, trenches etc. by applying the emulsion @ 5(five) litres per square meter of the surface area before starting construction work(supplying of neccessary tools and accessories by the contractor) as per the direction of the Department complete.
a) with aqueous emulsion having concentration 1:19 with chloropirophose solution(tricel or equivalent) and water, i.e. 1% solution.
Pre construction anti - termite treatment by applying in the entire levelled area after plinth filling and before laying floor by applying the emulsion @ 5 (five) litres per square meter of the surface to be spread with light rodding so as to ensure proper absorption by the filled up earth (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete.
a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
Pre construction anti - termite treatment by applying the soil along the external perimeter of the building (after construction completed) to a distance close to the plinth wall as specified and as directed by the deptt. up to a depth of 300mm making rod holes along the line @ 150mm apart to a depth of 300mm and applying emulsion @ 4.5 litres per running meter ensure moistening of the soil with emulsion (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete.
a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
PLINTH PROTECTION
Providing plinth protection with bricks flat laid in cement mortar 1: 4 and finished with 15mm thick cement plaster in prop. 1:2 with a floating coat of neat cement finish.
Providing drain with brick work in cement mortar in proportion 1:5 with half brick thick side walls and 100mm thick C.C (1:3:6) base over one brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shuttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified.
ii). 300mm wide and average 250mm deep with bed slope 1 in 150 with initial depth of 100mm.
RETAINING WALL TYPE -I
ASSUMING LENGTH= 6.0M
EARTHWORKS :
EARTHWORK IN EXCAVATION :
Earth work in excavation for foundation trenches of walls, retaining walls, footings of columns, steps and septic tank etc including refilling ( return filling ) the quantity as necessary after completing of work, breaking colds in return filling, dressing, watering and ramming etc.and removal of surplus earth with all lead and lifts as directed and specified in following classifications of soils including bailing out water where necessary as directed and specified.
(A) Up to a depth of 2 m below the existing the ground level.
b) in hard/dense soil
CEMENT CONCRETE WORKS
PLAIN CEMENT CONCRETE WORKS
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, wall, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately).
(a) In prop 1 cement : 3 sand : 6 coarse aggregate by volume
REINFORCED CEMENT CONCRETE.
Providing and laying plain/reinforced cement concrete works Cement coarse sand & 20mm down grade stone aggregate including dewatering if necessary,and curing complete but excluding cost of from work and reinforcment for reinforced cement concrete work (form work and reinforcement will be measured and paid separately)
(A)In sub-structure upto plinth
Foundation, Fotting,columns with base,tie and plinth beam, grade beam, pilecap, base slab, retaining walls,walls,walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level.
(P) Using admixture,Plasticiser etc. for air entraining, water reducing purposeds including addition of agent for changing normal setting time of conc. As required.
( b) Conc. Grade - M 20 ( Prorp.1:1.5:3 )
SHUTTERING/ FORMWORKS.
TIMBER SHUTTERING
Providing from work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0m and removal of the same for in-situ reinforced concrete and plain concrete work in.
Sides of tie beams, grade beams etc. at or below ground level.
(b) Using 25mm thick plank
MASONRY WORKS
Brick soling
Providing brick soiling in foundation and under floor with stone/best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering complete.
(a).Brick on flat soling.
STONE MASONARY WORK
Stone masonary work in retaining wall, wing wall, abutment, foundation, steps, plinth etc. in cement mortar in prop 1:6 with levelling course of 1:6:12 with both faces hammer dressed including bonding,providing face stone, through stone and centering including racking of joints, curing and supplying and all cariage of stone as directed including payment of forest royalty and sales tax and carriage.
(b) Coarse Rubble Masonry
PLASTERING WORK.
CEMENT PLASTERING WORK.
15mm thick Cement plaster in single coat on brick/concrete walls for interior plastering up to 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed.
(A) on raugh side
(b) In cement mortar 1:4
STEEL&IRON WORK.
REINFORCEMENT
Supplying,fitting and fixing in position reinforcement bars conforming to relevant I.S Code for R.C.C work/R.B walling including straightening cleaning cutting and bending to proper shapes and length as per details supplying and binding with 20G annealed black wire and placing in position with proper blocks supports chairs spacers etc.complete ( No extra measurement for lap,hook, chair, anchor etc.will be entertained in the measurement as they are included in the rate )(upto 1st fl level).
(a)From primary producer: TATA/SAIL/Jindal steel/shyam steel/RINL
(i) TMT Corrosion resistant steel( CRS)
RETAINING WALL TYPE -II
ASSUMING LENGTH= 6.0M
EARTHWORKS :
EARTHWORK IN EXCAVATION :
Earth work in excavation for foundation trenches of walls, retaining walls, footings of columns, steps and septic tank etc including refilling ( return filling ) the quantity as necessary after completing of work, breaking colds in return filling, dressing, watering and ramming etc.and removal of surplus earth with all lead and lifts as directed and specified in following classifications of soils including bailing out water where necessary as directed and specified.
(A) Up to a depth of 2 m below the existing the ground level.
b) in hard/dense soil
CEMENT CONCRETE WORKS
PLAIN CEMENT CONCRETE WORKS
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, wall, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately).
(a) In prop 1 cement : 3 sand : 6 coarse aggregate by volume
REINFORCED CEMENT CONCRETE.
Providing and laying plain/reinforced cement concrete works Cement coarse sand & 20mm down grade stone aggregate including dewatering if necessary,and curing complete but excluding cost of from work and reinforcment for reinforced cement concrete work (form work and reinforcement will be measured and paid separately)
(A)In sub-structure upto plinth
Foundation, Fotting,columns with base,tie and plinth beam, grade beam, pilecap, base slab, retaining walls,walls,walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level.
(P) Using admixture,Plasticiser etc. for air entraining, water reducing purposeds including addition of agent for changing normal setting time of conc. As required.
( b) Conc. Grade - M 20 ( Prorp.1:1.5:3 )
SHUTTERING/ FORMWORKS.
TIMBER SHUTTERING
Providing from work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0m and removal of the same for in-situ reinforced concrete and plain concrete work in.
Sides of tie beams, grade beams etc. at or below ground level.
(b) Using 25mm thick plank
MASONRY WORKS
Brick soling
Providing brick soiling in foundation and under floor with stone/best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering complete.
(a).Brick on flat soling.
STONE MASONARY WORK
Stone masonary work in retaining wall, wing wall, abutment, foundation, steps, plinth etc. in cement mortar in prop 1:6 with levelling course of 1:6:12 with both faces hammer dressed including bonding,providing face stone, through stone and centering including racking of joints, curing and supplying and all cariage of stone as directed including payment of forest royalty and sales tax and carriage.
(b) Coarse Rubble Masonry
PLASTERING WORK.
CEMENT PLASTERING WORK.
15mm thick Cement plaster in single coat on brick/concrete walls for interior plastering up to 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed.
(A) on raugh side
(b) In cement mortar 1:4
STEEL&IRON WORK.
REINFORCEMENT
Supplying,fitting and fixing in position reinforcement bars conforming to relevant I.S Code for R.C.C work/R.B walling including straightening cleaning cutting and bending to proper shapes and length as per details supplying and binding with 20G annealed black wire and placing in position with proper blocks supports chairs spacers etc.complete ( No extra measurement for lap,hook, chair, anchor etc.will be entertained in the measurement as they are included in the rate )(upto 1st fl level).
(a)From primary producer: TATA/SAIL/Jindal steel/shyam steel/RINL
(i) TMT Corrosion resistant steel( CRS)
RETAINING WALL TYPE III
ASSUMING LENGTH= 6.0M
EARTHWORKS :
EARTHWORK IN EXCAVATION :
Earth work in excavation for foundation trenches of walls, retaining walls, footings of columns, steps and septic tank etc including refilling ( return filling ) the quantity as necessary after completing of work, breaking colds in return filling, dressing, watering and ramming etc.and removal of surplus earth with all lead and lifts as directed and specified in following classifications of soils including bailing out water where necessary as directed and specified.
(A) Up to a depth of 2 m below the existing the ground level.
b) in hard/dense soil
CEMENT CONCRETE WORKS
PLAIN CEMENT CONCRETE WORKS
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, wall, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately).
(a) In prop 1 cement : 3 sand : 6 coarse aggregate by volume
STONE MASONARY WORK
Stone masonary work in retaining wall, wing wall, abutment, foundation, steps, plinth etc. in cement mortar in prop 1:6 with levelling course of 1:6:12 with both faces hammer dressed including bonding,providing face stone, through stone and centering including racking of joints, curing and supplying and all cariage of stone as directed including payment of forest royalty and sales tax and carriage.
(b) Coarse Rubble Masonry
PLASTERING WORK.
CEMENT PLASTERING WORK.
15mm thick Cement plaster in single coat on brick/concrete walls for interior plastering up to 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed.
(A) on raugh side
(b) In cement mortar 1:4
MS RAILING AT MIDDLE RETAINING WALL
CEMENT CONCRETE WORKS
PLAIN CEMENT CONCRETE WORKS
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, wall, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately).
(a) In prop 1 cement : 3 sand : 6 coarse aggregate by volume
REINFORCED CEMENT CONCRETE.
Providing and laying plain/reinforced cement concrete works Cement coarse sand & 20mm down grade stone aggregate including dewatering if necessary,and curing complete but excluding cost of from work and reinforcment for reinforced cement concrete work (form work and reinforcement will be measured and paid separately)
(B)In super structure from plinth level upto 1st floor level.
(ii)Columns, pillar, posts, struts, suspended floor, roof, landing, shelf, and support, balcony, lintel, sill band beam, girder, bressumer, cantilever, staircase including preparing the top surface and finishing of nosing.
P) Using admixture, plasticiser etc for air entraining, water reducing purposes including addition of agent for changing normal setting time of concrete as required.
b) M20 grade concrete or Prop. 1:1.5:3
SHUTTERING FORMWORKS.
TIMBER SHUTTERING( FORMWORK)
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in:
Columns, Pillars, Posts & Strut
(a) Square, Rectangular, polygonal in plan or any shape like Tee/L etc. having plane vertical face
(ii) Using 25mm thick plank
PLASTERING WORK.
CEMENT PLASTERING
10 mm thick Cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed.
(b) In cement mortar 1:4
PAINTING
CEMENT PAINT & PRIMER
a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
WEATHER COAT EXTERIOR PAINT.
Finishing old/ new wall with water proofing weather coat smooth anti-fungal exterior painting of Apex brand of Asian Paints and of required shade after cleaning and clearing the surface etc. including scaffolding complete as directed at all levels (two coats)
PAINTING ON STEEL AND OTHER METAL SURFACE
Applying primary coat over new steel and other metal surface over 100m in width or girth after preparing the surface by throughly cleaning oil,grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper.
a). With ready mixed "red-lead/ red oxide" primer.
Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter.
b). High gloss (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
STEEL&IRON WORK.
REINFORCEMENT
Supplying,fitting and fixing in position reinforcement bars conforming to relevant I.S Code for R.C.C work/R.B walling including straightening cleaning cutting and bending to proper shapes and length as per details supplying and binding with 20G annealed black wire and placing in position with proper blocks supports chairs spacers etc.complete(upto 1st fl level).
(a)From primary producer: TATA/SAIL/Jindal steel/shyam steel/RINL
(i) TMT Corrosion resistant steel( CRS)
MS RAILING
Providing, fitting, hoisting and fixing of roof trusses fabricated out of combination of any two or all of the following sections (i) Square section (ii) Rectangular Hollow section of specification RSH/SHS and (iii) M.S. circular hlollow section of Grade 210 including purlins, bottom runners and providing M.S. cleat, M.S. angle base plank, bolts and nuts with red oxide primer including fitting bottom runner and cleat etc. for fixing ceiling joist as per design complete as directed as per specifications.
a) Using TATA make RHS/SHS of Grade 310 conforming to relevant I.S. code 4923 : 1997
LAND DEVELOPMENT ( EARTH FILLING)
EARTH WORKS
Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified.
(A) Up to a depth of 2.00m below the existing ground level.
(b) In hard/ dense soil
EARTHWORK IN FILLING :
Raising low site around the building with approved soil obtained from outside by truck carriage including breaking clods dressing etc. complete including paying necessary forest royelty, sales tax, land compensation, Municipal gate fees, if any monopolyduty etc. (profile measurment to be taken and 12.5%deduction for shrinkage to be made from total quantity)etc. complete as directed and specified.
b) Other than guwahati city .
UNDER GROUND WATER TANK
CAPACITY : 15,000 LTR
EARTHWORK
EARTHWORK IN EXCAVATION :
Earth work in excavation for foundation trenches of walls, retaining walls, footings of columns, steps and septic tank etc including refilling ( return filling ) the quantity as necessary after completing of work, breaking colds in return filling, dressing, watering and ramming etc.and removal of surplus earth with all lead and lifts as directed and specified in following classifications of soils including bailing out water where necessary as directed and specified.
(A) Up to a depth of 2.00 m below the existing ground level.
b) in ordinary soil
BRICK WORK
Providing soiling in foundation and under floor with stone/best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering complete.
(c).Stone soling of thickness 150mm.( 3 times) total thickness 450mm
CEMENT CONCRETE WORKS
PLAIN CEMENT CONCRETE
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, wall, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately).
(a) In prop 1cement :3 sand :6 coarse aggregate by volume
REINFORCED CEMENT CONCRETE WORKS
Providing and laying plain/reinforced cement concrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary,and curing complete but excluding cost of from work and reinforcment for reinforced cement concrete work ( form work and reinforcement will be measured and paid separately)
(I) Using mixture machine
(a)In substructure up to plinth level
Foundation, Fotting,columns with base,tie and plinth beam, grade beam, pilecap, base slab, retaining walls,walls,walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level.
P) Using admixture, plasticiser etc for air entraining, water reducing purposes including addition of agent for changing normal setting time of concrete as required.
c) M25 grade concrete
PLYBOARD SHUTTERING
Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in:
Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties.
(a) For depth not exceeding 1.0M.
Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like.
(a) Floors etc. upto 200mm in thickness.
Vertical surface such as walls (any thickness), parapet walls, partitions and the like including attached pilasters, butresses, plinth and string courses and the like.
INSIDE PLASTER
WATERPROOFING, CONCRETE ADMIXTURE & CHEMICAL TREATMENT, REPAIR, REHABILITATION & RE-STRENTHENING OF STRUCTURES
15mm thick plastering of the surface the interior of concrete water tanks with cement mortar in prop 1:4 admixed with modified Styrene Butadiene Rubber based polymer like Sika Latex of Sika India Ltd./Dr. Sealkit Masterbond Latex (Asian Chemicals)/Rheomix 141 of BASF @200gms per bag of cement as specified and directed by the department complete.
STEEL&IRON WORK.
REINFORCEMENT
Supplying,fitting and fixing in position reinforcement bars conforming to relevant I.S Code for R.C.C work/R.B walling including straightening cleaning cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks supports chairs spacers etc.complete(No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate)(upto 1st floor level).
(A)From Primary producer : TATA/ SAIL/Jindal/Shyam steel/Rinl
(i) TMT Corrosion resistant steel(CRS) reinforcement bar
MAN HOLE COVER( Sanitary & water supply) volume -ii
Providing fitting and fixing 450mm dia 90mm thick CI Man hole cover and frame of 38kg weight complete as directed and specified.
DRIVE WAY AND PARKING DEVELOPMENT
EARTH WORK
Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified.
(b) In hard/ dense soil
SIDE BUMP
Stone masonary work in retaining wall, wing wall, abutment, foundation, steps, plinth etc. in cement mortar in prop 1:6 with levelling course of 1:6:12 with both faces hammer dressed including bonding, providing face stone, through stone and centering including racking of joints, curing and supplying and all carriage of stone as directed including payment of forest royalty and sales tax and carriage.
(b) Coarse Rubble Masonry
FILLING
(d) With stone dust obtained by truck carriage including loading and unloading to the site of work.
(b) Coarse Rubble Masonry
PREPARATION OF TRACK
Granular sub-base
Construction of granular sub-base providing close graded material, spreading in uniform layers with motor grade on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achive the desired density, complete as per Clause 401. (with an initial lead of 5Km) For Grading I Material
Water bound macadam
Providing, laying, spreading and compacting stoneaggregate of specified sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with 3-wheels steel/ vibratory roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screemning/ binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density(with an initial lead of 5 km) (i) Hand broken metal from blasted boulder
Gr.II Metal
Gr.III Metal
PAVERS BLOCK
Providing and laying of inter locking concrete block pavement (ICBP) with cement concrete paver block as per IS 15658-2006 of thickness 80mm and days compressive strength not less than 30 N/m over a layer of bedding sand of compacted thickness 30mm, laid either in stretcher/ running/ herringbone pattern of bonds as directed by the engineer and in proper level and grade and compacted with appropriate equipment such as plat vibrator along with spreading of a thin layer of joint filling sand to fill up the gaps between blocks including construction of edge restraint wherever required complete as per drawings and technical specification clause 1504 of MORD.
WALK WAY
EARTH WORK
Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified.
(a) In ordinary soil
FILLING
Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete.
(c).Stone soling of thickness 150mm.
CEMENT CONCRETE WORKS
PLAIN CEMENT CONCRETE WORKS
Plain cement concrete floor base in prop1:3:6 laid in alternate bays as specified with coarse agg. of size 13mm to 32mm including dewatering if necessary, and curing etc. complete.
b) 50mm thick
PAVER'S TILE
Proividing polished Multiwyn/DEVI/ VITA tiles of approved quality, size shape of specified thickness on pavers over a base course including cutting where necessary finished with flush pointing with Fix-A-Tile(Choksey/Sika/Pedelite/Rouf) white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed.
(B) DEVI Tiles (Pavers)
ii) Of size 300x300 mm of 30 thick
DRAIN ( 600 WIDTH X 700 DEPTH mm)
EARTHWORK IN EXCAVATION :
Earth work in excavation for foundation trenches of walls, retaining walls, footings of columns, steps and septic tank etc including refilling ( return filling ) the quantity as necessary after completing of work, breaking colds in return filling, dressing, watering and ramming etc.and removal of surplus earth with all lead and lifts as directed and specified in following classifications of soils including bailing out water where necessary as directed and specified.
(A)Up to a depth of 2 m below the existing the ground level.
(a) In ordinary soil
PLAIN CEMENT CONCRETE WORKS
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, wall, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately).
(a) In prop 1cement :3 sand :6 coarse aggregate by volume
REINFORCED CEMENT CONCRETE.
Providing and laying plain/reinforced cement concrete works Cement coarse sand & 20mm down grade stone aggregate including dewatering if necessary,and curing complete but excluding cost of from work and reinforcment for reinforced cement concrete work (form work and reinforcement will be measured and paid separately)
(A)In sub-structure upto plinth
Using mixture machine
(A) In substructure up to plinth level
Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level.
N) Without using admixture, plasticiser
a) M15 grade concrete or Prop. 1:2:4
BRICK WORK.
Providing brick soiling in foundation and under floor with stone/best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering complete.
(a)Brick on flat soling
PLASTERING WORK.
Cement plaster skirting with cement mortar in prop. 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement including rounding of junctions with floor.
(b) 20 mm thick
15mm thick plastering of the interior surface of concrete water tanks with cement mortar in prop 1:4 admixed with modified Styrene Butadiene Rubber based polymer like Sika Latex of Sika India Ltd./Dr. Sealkit Masterbond Latex (Asian Chemicals)/Rheomix 141 of BASF @ 200gms per bag of cement as specified and directed by the department complete.
STEEL&IRON WORK.
REINFORCEMENT
Supplying,fitting and fixing in position reinforcement bars conforming to relevant I.S Code for R.C.C work/R.B walling including straightening cleaning cutting and bending to proper shapes and length as per details supplying and binding with 20G annealed black wire and placing in position with proper blocks supports chairs spacers etc.complete(upto 1st fl level).
(a)From primary producer: TATA/SAIL/Jindal steel/shyam steel/RINL
(i) TMT Corrosion resistant steel( CRS)
PRE-CAST SLAB
Providing precast R.C.C slab over drain ,septic tank etc. in prop. 1:2:4 reinforced with 10mm M.S. bar @ 150mm centre both ways tying with 20 gauge black annealed wire with necessary shuttering , curing etc. complete including fixing in position as directed.
b) 75mm thick slab
Intermediate Silt Trap along Drain
EARTHWORK IN EXCAVATION :
Earth work in excavation for foundation trenches of walls, retaining walls, footings of columns, steps and septic tank etc including refilling ( return filling ) the quantity as necessary after completing of work, breaking colds in return filling, dressing, watering and ramming etc.and removal of surplus earth with all lead and lifts as directed and specified in following classifications of soils including bailing out water where necessary as directed and specified.
(A)Up to a depth of 2 m below the existing the ground level.
a)In ordinary soil.
BRICK WORK
Providing brick soiling in foundation and under floor with stone/best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering complete.
(c) Stone soling of thickness 150mm
PLAIN CEMENT CONCRETE
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, wall, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately).
(a) In prop 1cement :3 sand :6 coarse aggregate by volume
REINFORCED CEMENT CONCRETE.
Providing and laying plain/reinforced cement concrete works Cement coarse sand & 20mm down grade stone aggregate including dewatering if necessary,and curing complete but excluding cost of from work and reinforcment for reinforced cement concrete work (form work and reinforcement will be measured and paid separately)
(a)In substructure up to plinth level
(P) Using admixture,Plasticiser etc. for air entraining, water reducing purposeds including addition of agent for changing normal setting time of conc. As required.
Foundation, Fotting,columns with base,tie and plinth beam, grade beam, pilecap, base slab, retaining walls,walls,walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level.
SHUTTERING FORMWORKS.
Providing from work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4.0m and removal of the same for in-situ reinforced concrete and plain concrete work in.
Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like.
(a)Floors etc.upto 200mm in thickness.
PLASTERING WORK.
15mm thick Cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed.
(b) In cement mortar 1:4
Cement concrete works in topping 1:1:2 (1cement:1sand:2 graded aggregates on R.C.C floor, tread and rise of steps finished with a floating coat of neat cement using cement slurry for bond @2.75kg . Of cement per sq.m of floor (base concrete to be measured and paid separately)to be laid in panels including curing complete as directed.
(a) 15mm thick
STEEL&IRON WORK.
REINFORCEMENT
Supplying,fitting and fixing in position reinforcement bars conforming to relevant I.S Code for R.C.C work/R.B walling including straightening cleaning cutting and bending to proper shapes and length as per details supplying and binding with 20G annealed black wire and placing in position with proper blocks supports chairs spacers etc.complete(upto 1st floor level).
(b)TMT Bar
(ii)SAI/BISCON/SHYAM THERMEX
MAN HOLE COVER
Providing fitting and fixing 450mm dia. 90mm thick C.I. Man hole cover and frame of 58 Kg. weight complete as directed and specified.
DEEP TUBE WELL & BORING
Labour for sinking tube well with 40mm (internal) dia G.I. Pipes up to having strata, having potable water including fitting and fixing strainer hand pump and other accessories as directed complete as in any soil.
Labour for test boring with 40mm (internal) dia G.I. Pipes including keeping surplus of earth and every 2.00m after first 3.00m depth and delivering the same in nearest P.W.D. camp in the small tin container (container, scaffolding, tools etc. will have to be arranged by the contractor at his own cost).
Supplying fitting and fixing Hand pump for 40 mm dia tube well with all accessories complete as directed.
ii) Mayur
Supplying, fitting and fixing lift and force Maya hand pump of approved with all accessories complete as directed by the Department..
Labour for boring hole for inserting tube well pipes through different soil/ rock media including hire charges of drill pipes, scaffolding, tools and plants as necessary and taking out the same and lowering pipes, fittings complete as directed by the Department.
x) Bore hole of 300mm diameter
Supplying, fitting and fixing pipes plain/bevel ended for casing, conforming to relevant IS codes of practice including supplying and fitting of tube well accessories, lowering of assembly pipes concentrically in the borehole followed by supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department.
PVC PIPE
SUPREME /PRINCE / FUSION /SFMC Brand
viii) 200mm diameter
Supplying, fitting and fixing suction pipes plain/bevel ended, conforming to relevant IS codes of practice including supplying and fitting of accessories, lowering of assembly pipes concentrically in the casing pipes complete as directed.
B) PVC PIPE
SUPREME / PRINCE / FUSION /SFMC Brand
ix) 200mm diameter
Supplying fitting and fixing GI filter 2.00 metre long.
Supplying fitting and fixing check valve(non return valve)including thread to pipes
c)40mm diameter
Development of the tube well with compressor or by over pumping unit for 48 hours till sand free discharge is obtained.
Flushing clearing washing and watering of the tube well
AS PER MARKET PRICES ANALYSIS
Supplying, Testing and Commissioning of 2 or 3BHP Submerssible pump of approaved brand and make as per specification including all accessories like panel board, starter etc. complete in all respect as directed by the architect.
BOUNDARY WALL
Assuming Length =9m
TYPE- A
DISMANTLING
Demolishing RCC work including stacking of steel bars and disposal of unserviceable material as directed for all levels
SURFACE PREPARATION
(a) Removing white or colour wash by steel wire brushing and/ or scraping, sand papering and preparing the wall surface smooth including necessary repairs to scratches complete.
REINFORCED CEMENT CONCRETE.
Providing and laying plain/reinforced cement concrete works Cement coarse sand & 20mm down grade stone aggregate including dewatering if necessary,and curing complete but excluding cost of from work and reinforcment for reinforced cement concrete work (form work and reinforcement will be measured and paid separately)
(B)In super structure from plinth level upto 1st floor level.
(ii)Columns, pillar, posts, struts, suspended floor, roof, landing, shelf, and support, balcony, lintel, sill band beam, girder, bressumer, cantilever, staircase including preparing the top surface and finishing of nosing.
P) Using admixture, plasticiser etc for air entraining, water reducing purposes including addition of agent for changing normal setting time of concrete as required.
b) M20 Grade concrete or prop 1:1.5:3
SHUTTERING FORMWORKS.
TIMBER SHUTTERING( FORMWORK)
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in:
Columns, Pillars, Posts & Strut
(a) Square, Rectangular, polygonal in plan or any shape like Tee/L etc. having plane vertical face
(ii) Using 25mm thick plank
Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties.
(a) For depth not exceeding 1.0M.
(ii) Using 25mm thick plank
BRICK WORK.
(I) In superstructure upto 1st floor level including dewatering if necessary.
Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed in super-structure above plinth level up to 1st floor level.
(A) 112 mm thick brick wall.
(b) In proportion 1:4 (1 cement:4 sand)
PLASTERING WORK.
CEMENT PLASTERING
15mm thick Cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed.
(A) on raugh side
(b) In cement mortar 1:4
PAINTING
CEMENT PAINT & PRIMER
a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
WEATHER COAT EXTERIOR PAINT.
Finishing wall with water proofing weather coat anti-fungal premium acrylic smooth exterior finish of snowcem XT brand of Snowcem India Ltd. Of required shade on old/ new wall surfaces to give an even shade after cleaning and clearing the surface etc. including scaffolding complete as directed at all levels( 2 coats.).
STEEL&IRON WORK.
REINFORCEMENT
Supplying,fitting and fixing in position reinforcement bars conforming to relevant I.S Code for R.C.C work/R.B walling including straightening cleaning cutting and bending to proper shapes and length as per details supplying and binding with 20G annealed black wire and placing in position with proper blocks supports chairs spacers etc.complete(upto 1st fl level).
(a)From primary producer: TATA/SAIL/Jindal steel/shyam steel/RINL
(i) TMT Corrosion resistant steel( CRS)
FANCING
Supplying, fitting and fixing chain link fencing of 10 S.W.G, G.I. Wire 50mm x50mm mesh fitted to M.S angle iron post at 2000mm apart of specification detailed below including supplying, fitting and fixing hooks, eye bolts with nuts, staples and bolts including three horizontal lines of G.I wire 10 S.W.G at top,middle and bottom and with one vertical line to each fencing post for keeping the fencing tight and erect complete, including one coat of primer painting to M.S angle iron post in P.C.C base etc. with following.
BOUNDARY WALL
( TYPE -B)
DISMANTLING
Demolishing RCC work including stacking of steel bars and disposal of unserviceable material as directed for all levels
SURFACE PREPARATION
(a) Removing white or colour wash by steel wire brushing and/ or scraping, sand papering and preparing the wall surface smooth including necessary repairs to scratches complete.
REINFORCED CEMENT CONCRETE.
Providing and laying plain/reinforced cement concrete works Cement coarse sand & 20mm down grade stone aggregate including dewatering if necessary,and curing complete but excluding cost of from work and reinforcment for reinforced cement concrete work (form work and reinforcement will be measured and paid separately)
(B)In super structure from plinth level upto 1st floor level.
(ii)Columns, pillar, posts, struts, suspended floor, roof, landing, shelf, and support, balcony, lintel, sill band beam, girder, bressumer, cantilever, staircase including preparing the top surface and finishing of nosing.
P) Using admixture, plasticiser etc for air entraining, water reducing purposes including addition of agent for changing normal setting time of concrete as required.
b) M20 Grade concrete or prop 1:1.5:3
SHUTTERING FORMWORKS.
TIMBER SHUTTERING( FORMWORK)
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in:
Columns, Pillars, Posts & Strut
(a) Square, Rectangular, polygonal in plan or any shape like Tee/L etc. having plane vertical face
(ii) Using 25mm thick plank
Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties.
(a) For depth not exceeding 1.0M.
(ii) Using 25mm thick plank
PLASTERING WORK.
CEMENT PLASTERING
15mm thick Cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed.
(A) on raugh side
(b) In cement mortar 1:4
PAINTING
CEMENT PAINT & PRIMER
a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
WEATHER COAT EXTERIOR PAINT.
Finishing wall with water proofing weather coat anti-fungal premium acrylic smooth exterior finish of snowcem XT brand of Snowcem India Ltd. Of required shade on old/ new wall surfaces to give an even shade after cleaning and clearing the surface etc. including scaffolding complete as directed at all levels( 2 coats.).
STEEL&IRON WORK.
REINFORCEMENT
Supplying,fitting and fixing in position reinforcement bars conforming to relevant I.S Code for R.C.C work/R.B walling including straightening cleaning cutting and bending to proper shapes and length as per details supplying and binding with 20G annealed black wire and placing in position with proper blocks supports chairs spacers etc.complete(upto 1st fl level).
(a)From primary producer: TATA/SAIL/Jindal steel/shyam steel/RINL
(i) TMT Corrosion resistant steel( CRS)
FANCING
Supplying, fitting and fixing chain link fencing of 10 S.W.G, G.I. Wire 50mm x50mm mesh fitted to M.S angle iron post at 2000mm apart of specification detailed below including supplying, fitting and fixing hooks, eye bolts with nuts, staples and bolts including three horizontal lines of G.I wire 10 S.W.G at top,middle and bottom and with one vertical line to each fencing post for keeping the fencing tight and erect complete, including one coat of primer painting to M.S angle iron post in P.C.C base etc. with following.
a) Corner and end posts with M.S angle of size 50mmx50mmx 5mm and length not less than 1800mm only duly slotted and bottom torqued with two numbers as stay posts..
b). Intermediate post with M.S angle of size 40mmx40mmx5mm and length not less than 1800mm only duly slotted and bottom torqued and splayed.
c).Stay post with M.S angle of size 35 mmx35mmx5mm and length not less than 1800mm duly slotted and bottom torqued and splayed. All M.S angle iron posts are to be fitted to P.C.C base embedded not less than 600mm (P.C.C. work shall be measured and paid separately).
BOUNDARY WALL
TYPE - C
DISMANTLING
Demolishing RCC work including stacking of steel bars and disposal of unserviceable material as directed for all levels
SURFACE PREPARATION
(a) Removing white or colour wash by steel wire brushing and/ or scraping, sand papering and preparing the wall surface smooth including necessary repairs to scratches complete.
REINFORCED CEMENT CONCRETE.
Providing and laying plain/reinforced cement concrete works Cement coarse sand & 20mm down grade stone aggregate including dewatering if necessary,and curing complete but excluding cost of from work and reinforcment for reinforced cement concrete work (form work and reinforcement will be measured and paid separately)
(B)In super structure from plinth level upto 1st floor level.
(ii)Columns, pillar, posts, struts, suspended floor, roof, landing, shelf, and support, balcony, lintel, sill band beam, girder, bressumer, cantilever, staircase including preparing the top surface and finishing of nosing.
P) Using admixture, plasticiser etc for air entraining, water reducing purposes including addition of agent for changing normal setting time of concrete as required.
b) M20 Grade concrete or prop 1:1.5:3
SHUTTERING FORMWORKS.
TIMBER SHUTTERING( FORMWORK)
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in:
Columns, Pillars, Posts & Strut
(a) Square, Rectangular, polygonal in plan or any shape like Tee/L etc. having plane vertical face
(ii) Using 25mm thick plank
Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties.
(a) For depth not exceeding 1.0M.
(ii) Using 25mm thick plank
PLASTERING WORK.
CEMENT PLASTERING
15mm thick Cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed.
(A) on raugh side
(b) In cement mortar 1:4
PAINTING
CEMENT PAINT & PRIMER
a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
WEATHER COAT EXTERIOR PAINT.
Finishing wall with water proofing weather coat anti-fungal premium acrylic smooth exterior finish of snowcem XT brand of Snowcem India Ltd. Of required shade on old/ new wall surfaces to give an even shade after cleaning and clearing the surface etc. including scaffolding complete as directed at all levels( 2 coats.).
STEEL&IRON WORK.
REINFORCEMENT
Supplying,fitting and fixing in position reinforcement bars conforming to relevant I.S Code for R.C.C work/R.B walling including straightening cleaning cutting and bending to proper shapes and length as per details supplying and binding with 20G annealed black wire and placing in position with proper blocks supports chairs spacers etc.complete(upto 1st fl level).
(a)From primary producer: TATA/SAIL/Jindal steel/shyam steel/RINL
(i) TMT Corrosion resistant steel( CRS)
ORNAMENTAL GRILL
Providing, fitting and fixing M.S. grill of required pattern for windows/ clerestory windows/ opening with M.S. flats at required spacing in frame all round, squre or round M.S. bars with round headed bolts and nuts or screws.
Ornamental Grill
(c) Fixed to Brickwork/P.C.C/R.C.C.
LANDSCAPING
LAWN MAKING BY DIBBLING
(a) By Doob grass (Cynodon dactylon)
(b) By Carpet grass (Axonopus affinis)
LAWN MAKING BY TURFING
(a) By Bahpotia grass and Doob grass (Cynodon dactylon) :
(b) BY CARPET GRASS (Axonopus affinis) :
POT PLANTING
Supplying and planting of terrestrial orchids with required size of pot including filling the pot to the top surface with appropriate soil media made of garden soil, river sand, cow-dung, leaf mould, fertilizer, pesticides as per specification and necessary maintenance for a period of 4 months from the date of planting complete as specified and directed . (Mixing of different ingredients of soil media to be made in presence of Deptt. official / Specialist concerned)
(A) With Aeirides
(I) Using earthen pot of 30 cm dia.
(II) Using earthen pot of 60 cm dia.
(III) Using concrete pot of 60 cm dia.
(D) With Vanda (hybrid)
(I) Using earthen pot of 30 cm dia.
(II) Using earthen pot of 60 cm dia.
III) Using concrete pot of 60 cm dia.
Supplying and planting of house plants in required size of pot including filling the pot to the top surface with appropriate soil media of garden soil, river sand, cow-dung, leaf mould, fertilizer, pesticides as per specification and necessary maintenance for a period of 6 months from the date of planting complete as specified and directed . (Mixing of different ingredients of soil media to be made in presence of Deptt. official / Specialist concerned)
(A) With Fancy leaf caladium/Coleus
(i) Using earthen pot of 30 cm dia.
(ii) Using earthen pot of 60 cm dia.
(iii) Using concrete pot of 60 cm dia.
(B) With Indian rubber plant / Prayer plant
(i) Using earthen pot of 30 cm dia.
(ii) Using earthen pot of 60 cm dia.
(iii) Using concrete pot of 60 cm dia.
(C) With Fragrant dracaena / Silver net leaf / Philodendron / Devil's back bone /Peperomea/Croton
(i) Using earthen pot of 30 cm dia.
(ii) Using earthen pot of 60 cm dia.
(iii) Using concrete pot of 60 cm dia.
(D) With Peacock/spider/Umbrella
(i) Using earthen pot of 30 cm dia.
(ii) Using earthen pot of 60 cm dia.
(iii) Using concrete pot of 60 cm dia.
(E) With Maiden hair fern/Aloe/Boston fern/Swiss cheese plant/Forget me not
(i) Using earthen pot of 30 cm dia.
(ii) Using earthen pot of 60 cm dia.
(iii) Using concrete pot of 60 cm dia.
(F) With Marry Christmas begonia / Polypodium / Aluminium plant
(I) Using earthen pot of 30 cm dia.
(II) Using earthen pot of 60 cm dia.
(III) Using concrete pot of 60 cm dia.
(G) With English Ivy
(I) Using earthen pot of 30 cm dia.
(II) Using earthen pot of 60 cm dia.
(III) Using concrete pot of 60 cm dia.
(H) With Iron Cross Begonia
(I) Using earthen pot of 30 cm dia.
(II) Using earthen pot of 60 cm dia.
(III) Using concrete pot of 60 cm dia.
(I) With Anthurium
(J) With Selloum
(K) With Birdnest fern/Good luck plant
Supplying and planting of palms with required size of pot including filling the pot to the top surface with appropriate soil media made of garden soil, river sand, cow-dung, leaf mould, fertilizer, pesticides as per specification and necessary maintenance for a period of 4 months from the date of planting complete as specified and directed . (Mixing of different ingredients of soil media to be made in presence of Deptt. official / Specialist concerned)
(A) With Bottle palm
(I) Using earthen pot of 30 cm dia.
(II) Using earthen pot of 60 cm dia.
(III) Using concrete pot of 60 cm dia.
(B) With Erica palm (Butterfly palm)/ Kentia palm
(I) Using earthen pot of 30 cm dia.
(II) Using earthen pot of 60 cm dia.
(III) Using concrete pot of 60 cm dia.
(C) With Chinese Palm
(I) Using earthen pot of 30 cm dia.
(II) Using earthen pot of 60 cm dia.
(III) Using concrete pot of 60 cm dia.
(D) With Fan Palm /Finger palm
(I) Using earthen pot of 30 cm dia.
(II) Using earthen pot of 60 cm dia.
(III) Using concrete pot of 60 cm dia.
Supplying and planting of cactus in required size of pot including filling the pot to the top surface with appropriate soil media made of garden soil, sand, cow-dung, fertilizer, pesticides as per specification and necessary maintenance for a period of 6 months from the date of planting complete as specified and directed . (Mixing of different ingredients of soil media to be made in presence of Deptt. official / Specialist concerned)
(A) With Peanut Cactus / Rat tail Cactus
(I) Using earthen pot of 30 cm dia.
(II) Using earthen pot of 60 cm dia.
(III) Using concrete pot of 60 cm dia.
(B) With Prickly pear
(I) Using earthen pot of 30 cm dia.
(II) Using earthen pot of 60 cm dia.
(III) Using concrete pot of 60 cm dia.
(C) With Parodia globular
(I) Using earthen pot of 30 cm dia.
(II) Using earthen pot of 60 cm dia.
(III) Using concrete pot of 60 cm dia.
BED PLANTING
Supplying and planting of Dahlia / Chrysanthemum / Gladiolus on the ground ( bed planting, bed size 45 cm x 45 cm x 45 cm) including the preparation of the soil, providing organic manure and fertilizer, pesticides as per specification and necessary maintenance for a period of 4 months from the date of planting complete as specified and directed .
HEDGE PLANTING / EXTERNAL HEDGE
Supplying and planting of suitable plant materials for preparation protective / external hedge (50 cm wide) including the preparation of the ground by mixing organic manure and fertilizers as per specification and necessary maintenance for a period of one year from the date of planting complete as specified and directed .
(A) ADOPTING SINGLE ROW PLANTING METHOD
(i) With Duranta
(ii) With Kamini
(iii) With Chinese Bamboo
(iv) With Thuja / Ixora
(B) ADOPTING CROSS WISE DOUBLE ROW PLANTING METHOD
(i) With Duranta
(ii) With Kamini
(iii) With Chinese Bamboo
(iv) With Thuja / Ixora
EDGE PLANTING / INTERNAL HEDGE
Supplying and planting of suitable plant materials for edge making / Internal hedge(20 cm wide) including the preparation of the ground by mixing organic manure and fertilizers as per specification and necessary maintenance for a period of one year from the date of planting complete as specified and directed .
(A) ADOPTING SINGLE ROW PLANTING METHOD
(i) With Duranta
(ii) With Coleus
(iii) With Brindavan / Latifolius
(iv) With Acalypha wilkesiana
(v) With Acer palmatum
(B) ADOPTING CROSS WISE DOUBLE ROW PLANTING METHOD
(i) With Duranta
(ii) With Coleus
(iii) With Brindavan / Latifolius
(iv) With Acalypha wilkesiana
(v) With Acer palmatum
TREE PLANTING
Supplying and planting of ornamental trees (1'-0" height sapling) including pit making ( 60 cm x 60 cm x 60 cm ), filling the pit with appropriate soil media, manure and fertilizers as per specification and necessary maintenance for a period of one year from the date of planting complete as specified and directed .
SHADE TREE
(A) Neem / Mahaneem / Beef wood / Bakul / Acacia / Siris / Devils tree / Kadam / Palash / Pink Cassia / peepal / Silver oak / Simalu / Ajar
(B) Kanchan / Nahar / Arjunu
(C) Sonaru
(D) Bottle Brush / Nil Gulmohar / Debadaru / Weeping Willow
(E) Ravenala
(F) Paine
(G) Christmas tree / Kuki
Flowering Tree
(A) Gulmohar / Ashok
(B) Kanchan
SHRUB PLANTING
Supplying and planting of ornamental shrub ( below 1'-0" height ) including pit making ( 60 cm x 60 cm x 60 cm ), filling the pit with appropriate soil media, manure and fertilizers as per specification and necessary maintenance for a period of one year from the date of planting complete as specified and directed .
(A) Radhachura / Krishnachura / Rat ki rani / Ixora / Jetuka
(B) Allmanda / Khorika zai / May flower / Kamini / Kathanda / Tecoma / Acalypha / Bougainvillea / Dracaena / Togor / Nilakantha / Mussaenda
(C) Korobi / Azalea
(D) Thuja
(E) Poinsettia / Forget me not
AQUATIC PLANT
Supplying and planting of aquatic plants ( water Lily and Lotus )after preparation of under water soil including organic manuring, supplying the required quantity of water and maintenance for a period of one year from the date of completion complete as specified and directed.
Preparation of a carpet bedding by raising the backside of the bed to a height of 45 cm (average) after mixing organic manure, fertilizer including supplying and planting of grass and specimen plants (Brindavan) to engrave the desired letters, necessary maintenance for a period of 6 months from the date of planting complete as directed and specified by the department.
Construction of a pergola ( Width = 2.0 m, Height of the side posts = 1.8 m, Height at the apex = 2.8 m) with angle iron of size 50 mm x 50 mm x 5 mm (placing at 2000 mm apart ) embedding the iron posts in P.C.C. base ( not less than 600 mm) covering at the top and sides by chain link fencing, painting one coat of primer and two coats of paint including supplying and planting of flowering climbers as enclosed from both sides ( 3 nos. per metre in one side ) of the pergola to facilitate climbing by pit making (30 cm x 30 cm x 30 cm) filling the pit with the mixture of soil and organic manure and necessary maintenance by trimming etc complete as specified and directed by the department. (P.C.C. and soling to be measured and paid separately)
Supplying and placing of orchid house of size 3.00 m x 1.5 m x 2.00 m with tub stand, make of 15 mm dia. G.I. Pipe with M.S. rod, M.S. flat etc. including roof frame, painting two coats, covering the roof with 75 % heat absorbing black nets and three sides with wire net complete as directed and specified.
Edging with bricks laid dry lengthwise including excavation, refilling, consolidating with hand packing and spreading neatly surplus earth within a lead of 50 m.
Half brick circular tree guard internal diametre 1.25 m and height 1.2 m above ground and 0.02 m below ground bottom two coarses laid dry and top three coarses in cement mortar 1:6 and the intermediate coarses being in dry honey comb masonry as per design complete.
RENOVATION WORKS OF HISTORICAL POND
CEMENT CONCRETE WORKS
PLAIN CEMENT CONCRETE WORKS
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, wall, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately).
(a) In prop 1 cement : 3 sand : 6 coarse aggregate by volume
REINFORCED CEMENT CONCRETE.
Providing and laying plain/reinforced cement concrete works Cement coarse sand & 20mm down grade stone aggregate including dewatering if necessary,and curing complete but excluding cost of from work and reinforcment for reinforced cement concrete work (form work and reinforcement will be measured and paid separately)
(B)In super structure from plinth level upto 1st floor level.
(ii)Columns, pillar, posts, struts, suspended floor, roof, landing, shelf, and support, balcony, lintel, sill band beam, girder, bressumer, cantilever, staircase including preparing the top surface and finishing of nosing.
P) Using admixture, plasticiser etc for air entraining, water reducing purposes including addition of agent for changing normal setting time of concrete as required.
b) M20 grade concrete or Prop. 1:1.5:3
SHUTTERING FORMWORKS.
TIMBER SHUTTERING( FORMWORK)
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in:
Sides of tie beams, grade beams etc. at or below ground level.
(b) Using 25mm thick plank
Columns, Pillars, Posts & Strut
(a) Square, Rectangular, polygonal in plan or any shape like Tee/L etc. having plane vertical face
(ii) Using 25mm thick plank
PLASTERING WORK.
CEMENT PLASTERING
10 mm thick Cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed.
(b) In cement mortar 1:4
PAINTING
CEMENT PAINT & PRIMER
a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
WEATHER COAT EXTERIOR PAINT.
Finishing old/ new wall with water proofing weather coat smooth anti-fungal exterior painting of Apex brand of Asian Paints and of required shade after cleaning and clearing the surface etc. including scaffolding complete as directed at all levels (two coats)
PAINTING ON STEEL AND OTHER METAL SURFACE
Applying primary coat over new steel and other metal surface over 100m in width or girth after preparing the surface by throughly cleaning oil,grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper.
a). With ready mixed "red-lead/ red oxide" primer.
Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter.
b). High gloss (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
STEEL&IRON WORK.
REINFORCEMENT
Supplying,fitting and fixing in position reinforcement bars conforming to relevant I.S Code for R.C.C work/R.B walling including straightening cleaning cutting and bending to proper shapes and length as per details supplying and binding with 20G annealed black wire and placing in position with proper blocks supports chairs spacers etc.complete(upto 1st fl level).
(a)From primary producer: TATA/SAIL/Jindal steel/shyam steel/RINL
(i) TMT Corrosion resistant steel( CRS)
MS RAILING
Providing, fitting, hoisting and fixing of roof trusses fabricated out of combination of any two or all of the following sections (i) Square section (ii) Rectangular Hollow section of specification RSH/SHS and (iii) M.S. circular hlollow section of Grade 210 including purlins, bottom runners and providing M.S. cleat, M.S. angle base plank, bolts and nuts with red oxide primer including fitting bottom runner and cleat etc. for fixing ceiling joist as per design complete as directed as per specifications.
a) Using TATA make RHS/SHS of Grade 310 conforming to relevant I.S. code 4923 : 1997
External water supply, Plumbing and over head PCVC Tank
External water supply pipe
Piping
Supplying fitting and fixing Pipes with all necessary fittings in exposed or in trenches including trenching and refilling the same etc complete as directed
B) uPVC pipe with uPVC fittings ( Using uPVC high pressure pipe) (Using SUPREME/ PRINCE/ SFMC/ FUSION brand pipe)
iv) 32 mm diameter
v) 40 mm diameter
vi) 50mm diameter
viii) 75mm diameter
ix) 90mm diameter
x) 110mm diameter
OVER HEAD WATER TANK
Supplying and placing plastic cylindrical vertical claused top (PCVC) tank of Sintex / Polycon / Patton make over the stagging with manhole cover with locking and cleaning arrangement including providing pads of size as required for inlet and outlet pipes
2000 Lt capacity
(a) Sintex make
MOTOR
Supplying fitting, fixing, testing and commissioning of following capacity motor (Crompton Greaves/ Aquatic/ CRI/ V-Guard make) complete with necessary connection as approved, specified and directed by the Department
2 HP three phase 1440 rpm/1500 rpm
SEPTIC TANK
NUMBER OF USERS: 100
EARTHWORK
EARTHWORK IN EXCAVATION :
Earth work in excavation for foundation trenches of walls, retaining walls, footings of columns, steps and septic tank etc including refilling ( return filling ) the quantity as necessary after completing of work, breaking colds in return filling, dressing, watering and ramming etc.and removal of surplus earth with all lead and lifts as directed and specified in following classifications of soils including bailing out water where necessary as directed and specified.
(A) Up to a depth of 2.00 m below the existing ground level.
b) in hard/dense soil
CEMENT CONCRETE WORKS
PLAIN CEMENT CONCRETE WORKS
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, wall, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately).
(a) In prop 1 cement : 3 sand : 6 coarse aggregate by volume
FLAT BRICK SOLING
Providing soiling in foundation and under floor with stone/best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering complete.
(a) Brick on flat soling
REINFORCED CEMENT CONCRETE
Providing and laying plain/reinforced cement concrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary,and curing complete but excluding cost of from work and reinforcment for reinforced cement concrete work ( form work and reinforcement will be measured and paid separately)
(I) Using mixture machine
(a)In substructure up to plinth level
Foundation, Footing,columns with base,tie and plinth beam, grade beam, pilecap, base slab, retaining walls,walls of septic tank, inspection pit and the like and other works not less than 100 mm thick up to plinth level.
P) Using admixture, plasticiser etc for air entertaining, water reducing purpose including addition of agent for changing normal setting time concrete as required.
b) M 20 grade concrete or prop.1:1.5:3
BRICK WORK :
Brick work in cement morter with 1st class brick including racking out joints and curing compete as directed.
(I) In sub-structure upto plinth level including dewatering if necessary
(b) In prop: 1:4
1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (providing M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately)
(A) 112mm thick brick wall
(a) In cement mortar in proportion 1:4. (1 cement:4 sand)
SHUTTERING WORKS
SHUTTERING (FORMWORK)
Providing formwork of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and proping etc. height of proping and centering below supporting floor to ceiling not exceding 4.0 m and removal of the same for in-situ reinforced concrete and plain concrete work in:
Foundation, footings, bases of columns, pile cap, raft and mass concrete works, etc.
Using 25 mm thick plank.
STEEL AND IRON WORK
REINFORCEMENT
Supplying,fitting and fixing in position reinforcement bars conforming to relevant I.S Code for R.C.C work/R.B walling including straightening cleaning cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks supports chairs spacers etc.complete(No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate)(upto 1st floor level).
(A)From Primary producer : TATA/ SAIL/Jindal/Shyam steel/Rinl
(i) TMT Corrosion resistant steel(CRS) reinforcement bar
PLASTERING
CEMENT PLASTERING
10 mm thick cement plaster in single coat on fair side of brick / concrete walls for interior plastering up to 1st floor level including arises, and / or rounded angles not exceeding 80 mm grith and finished even and smooth including curing complete as directed.
a) In cement morter 1:3
WATER PROOFING OF CHAJJAS ROOF SLABS TERRACES SUNKEN SLABS SEPTIC TANK OH TANK RAFT SLAB IN BASEMENT WALLS ETC.
22.3.1Supplying mixing laying and applying the following waterproofing systems over Raft slabs Roof slabs Terraces etc.including curing complete as specified and directed by the Department at all levels.
(i) 1mm thick single coat of Master Crete M-81 of Choksey Chemicals/Dr. Sealkit Sealcrete(Asian Chemicals)/Rheomix 131 of BASF mixed with cement in the ratio 1:2 as a prime coat.
(ii) 3mm thick Polymer modified mortar Cement sand mortar (in prop 1:3)mixed with Master Crete M-81/Dr. Sealkit Sealcrete (Asian Chemicals)/RHEOMIX 131 of BASF @15% by weight of cement.
(iii) 1mm thick coat of Master Crete M-81/Dr. Sealkit Sealcrete (Asian Chemicals)/RHEOMIX) 131 of BASF mixed with cement in the ratio 1:2 as final coat.
1.29 MANHOLE COVER ( sanitary & water supply)volume- ii
Providing fitting and fixing 450mm dia 90mm thick CI Man hole cover and frame of 38kg weight complete as directed and specified.
SEPTIC TANK
NUMBER OF USERS: 50
EARTHWORK
EARTHWORK IN EXCAVATION :
Earth work in excavation for foundation trenches of walls, retaining walls, footings of columns, steps and septic tank etc including refilling ( return filling ) the quantity as necessary after completing of work, breaking colds in return filling, dressing, watering and ramming etc.and removal of surplus earth with all lead and lifts as directed and specified in following classifications of soils including bailing out water where necessary as directed and specified.
(A) Up to a depth of 2.00 m below the existing ground level.
b) in hard/dense soil
CEMENT CONCRETE WORKS
PLAIN CEMENT CONCRETE WORKS
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, wall, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately).
(a) In prop 1 cement : 3 sand : 6 coarse aggregate by volume
FLAT BRICK SOLING
Providing soiling in foundation and under floor with stone/best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering complete.
(a) Brick on flat soling
REINFORCED CEMENT CONCRETE
Providing and laying plain/reinforced cement concrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary,and curing complete but excluding cost of from work and reinforcment for reinforced cement concrete work ( form work and reinforcement will be measured and paid separately)
(I) Using mixture machine
(a)In substructure up to plinth level
Foundation, Footing,columns with base,tie and plinth beam, grade beam, pilecap, base slab, retaining walls,walls of septic tank, inspection pit and the like and other works not less than 100 mm thick up to plinth level.
P) Using admixture, plasticiser etc for air entertaining, water reducing purpose including addition of agent for changing normal setting time concrete as required.
b) M 20 grade concrete or prop.1:1.5:3
BRICK WORK :
Brick work in cement morter with 1st class brick including racking out joints and curing compete as directed.
(I) In sub-structure upto plinth level including dewatering if necessary
(b) In prop: 1:4
1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (providing M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately)
(A) 112mm thick brick wall
(a) In cement mortar in proportion 1:4. (1 cement:4 sand)
SHUTTERING WORKS
SHUTTERING (FORMWORK)
Providing formwork of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and proping etc. height of proping and centering below supporting floor to ceiling not exceding 4.0 m and removal of the same for in-situ reinforced concrete and plain concrete work in:
Foundation, footings, bases of columns, pile cap, raft and mass concrete works, etc.
Using 25 mm thick plank.
STEEL AND IRON WORK
REINFORCEMENT
Supplying,fitting and fixing in position reinforcement bars conforming to relevant I.S Code for R.C.C work/R.B walling including straightening cleaning cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks supports chairs spacers etc.complete(No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate)(upto 1st floor level).
(A)From Primary producer : TATA/ SAIL/Jindal/Shyam steel/Rinl
(i) TMT Corrosion resistant steel(CRS) reinforcement bar
PLASTERING
CEMENT PLASTERING
10 mm thick cement plaster in single coat on fair side of brick / concrete walls for interior plastering up to 1st floor level including arises, and / or rounded angles not exceeding 80 mm grith and finished even and smooth including curing complete as directed.
a) In cement morter 1:3
WATER PROOFING OF CHAJJAS ROOF SLABS TERRACES SUNKEN SLABS SEPTIC TANK OH TANK RAFT SLAB IN BASEMENT WALLS ETC.
22.3.1Supplying mixing laying and applying the following waterproofing systems over Raft slabs Roof slabs Terraces etc.including curing complete as specified and directed by the Department at all levels.
(i) 1mm thick single coat of Master Crete M-81 of Choksey Chemicals/Dr. Sealkit Sealcrete(Asian Chemicals)/Rheomix 131 of BASF mixed with cement in the ratio 1:2 as a prime coat.
(ii) 3mm thick Polymer modified mortar Cement sand mortar (in prop 1:3)mixed with Master Crete M-81/Dr. Sealkit Sealcrete (Asian Chemicals)/RHEOMIX 131 of BASF @15% by weight of cement.
(iii) 1mm thick coat of Master Crete M-81/Dr. Sealkit Sealcrete (Asian Chemicals)/RHEOMIX) 131 of BASF mixed with cement in the ratio 1:2 as final coat.
SEPTIC TANK
NUMBER OF USERS: 10
EARTHWORK
EARTHWORK IN EXCAVATION :
Earth work in excavation for foundation trenches of walls, retaining walls, footings of columns, steps and septic tank etc including refilling ( return filling ) the quantity as necessary after completing of work, breaking colds in return filling, dressing, watering and ramming etc.and removal of surplus earth with all lead and lifts as directed and specified in following classifications of soils including bailing out water where necessary as directed and specified.
(A) Up to a depth of 2.00 m below the existing ground level.
b) in hard/dense soil
CEMENT CONCRETE WORKS
PLAIN CEMENT CONCRETE WORKS
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, wall, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately).
(a) In prop 1 cement : 3 sand : 6 coarse aggregate by volume
FLAT BRICK SOLING
Providing soiling in foundation and under floor with stone/best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering complete.
(a) Brick on flat soling
REINFORCED CEMENT CONCRETE
Providing and laying plain/reinforced cement concrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary,and curing complete but excluding cost of from work and reinforcment for reinforced cement concrete work ( form work and reinforcement will be measured and paid separately)
(I) Using mixture machine
(a)In substructure up to plinth level
Foundation, Footing,columns with base,tie and plinth beam, grade beam, pilecap, base slab, retaining walls,walls of septic tank, inspection pit and the like and other works not less than 100 mm thick up to plinth level.
P) Using admixture, plasticiser etc for air entertaining, water reducing purpose including addition of agent for changing normal setting time concrete as required.
b) M 20 grade concrete or prop.1:1.5:3
BRICK WORK :
Brick work in cement morter with 1st class brick including racking out joints and curing compete as directed.
(I) In sub-structure upto plinth level including dewatering if necessary
(b) In prop: 1:4
1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (providing M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately)
(A) 112mm thick brick wall
(a) In cement mortar in proportion 1:4. (1 cement:4 sand)
SHUTTERING WORKS
SHUTTERING (FORMWORK)
Providing formwork of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and proping etc. height of proping and centering below supporting floor to ceiling not exceding 4.0 m and removal of the same for in-situ reinforced concrete and plain concrete work in:
Foundation, footings, bases of columns, pile cap, raft and mass concrete works, etc.
Using 25 mm thick plank.
STEEL AND IRON WORK
REINFORCEMENT
Supplying,fitting and fixing in position reinforcement bars conforming to relevant I.S Code for R.C.C work/R.B walling including straightening cleaning cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks supports chairs spacers etc.complete(No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate)(upto 1st floor level).
(A)From Primary producer : TATA/ SAIL/Jindal/Shyam steel/Rinl
(i) TMT Corrosion resistant steel(CRS) reinforcement bar
PLASTERING
CEMENT PLASTERING
10 mm thick cement plaster in single coat on fair side of brick / concrete walls for interior plastering up to 1st floor level including arises, and / or rounded angles not exceeding 80 mm grith and finished even and smooth including curing complete as directed.
a) In cement morter 1:3
WATER PROOFING OF CHAJJAS ROOF SLABS TERRACES SUNKEN SLABS SEPTIC TANK OH TANK RAFT SLAB IN BASEMENT WALLS ETC.
22.3.1Supplying mixing laying and applying the following waterproofing systems over Raft slabs Roof slabs Terraces etc.including curing complete as specified and directed by the Department at all levels.
(i) 1mm thick single coat of Master Crete M-81 of Choksey Chemicals/Dr. Sealkit Sealcrete(Asian Chemicals)/Rheomix 131 of BASF mixed with cement in the ratio 1:2 as a prime coat.
(ii) 3mm thick Polymer modified mortar Cement sand mortar (in prop 1:3)mixed with Master Crete M-81/Dr. Sealkit Sealcrete (Asian Chemicals)/RHEOMIX 131 of BASF @15% by weight of cement.
(iii) 1mm thick coat of Master Crete M-81/Dr. Sealkit Sealcrete (Asian Chemicals)/RHEOMIX) 131 of BASF mixed with cement in the ratio 1:2 as final coat.
MANHOLE COVER ( sanitary & water supply)volume- ii
Providing fitting and fixing 450mm dia 90mm thick CI Man hole cover and frame of 38kg weight complete as directed and specified.
RAIN WATER HARVESTING SYSTEM
RAINWATER HERVESTING SYSTEM
Storage of Rainwater
Supplying, fitting and fixing of Water storage tank ISI Marked, conforming to IS:12701/1996 (with uptodate amendment). (Excluding Civil Works)
CIVIL WORKS
EARTHWORK IN EXCAVATION :
Earth work in excavation for foundation trenches of walls, retaining walls, footings of columns, steps and septic tank etc including refilling ( return filling ) the quantity as necessary after completing of work, breaking colds in return filling, dressing, watering and ramming etc.and removal of surplus earth with all lead and lifts as directed and specified in following classifications of soils including bailing out water where necessary as directed and specified.
(A) Up to a depth of 2.00 m below the existing ground level.
b) in ordinary soil
BRICK WORK
Providing soiling in foundation and under floor with stone/best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering complete.
(c).Stone soling of thickness 150mm.( 3 times) total thickness 450mm
CEMENT CONCRETE WORKS
PLAIN CEMENT CONCRETE
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, wall, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately).
(a) In prop 1cement :3 sand :6 coarse aggregate by volume
REINFORCED CEMENT CONCRETE WORKS
Providing and laying plain/reinforced cement concrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary,and curing complete but excluding cost of from work and reinforcment for reinforced cement concrete work ( form work and reinforcement will be measured and paid separately)
(I) Using mixture machine
(a)In substructure up to plinth level
Foundation, Fotting,columns with base,tie and plinth beam, grade beam, pilecap, base slab, retaining walls,walls,walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level.
P) Using admixture, plasticiser etc for air entraining, water reducing purposes including addition of agent for changing normal setting time of concrete as required.
c) M25 grade concrete
PLYBOARD SHUTTERING
Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in:
Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties.
(a) For depth not exceeding 1.0M.
Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like.
(a) Floors etc. upto 200mm in thickness.
Vertical surface such as walls (any thickness), parapet walls, partitions and the like including attached pilasters, butresses, plinth and string courses and the like.
INSIDE PLASTER
WATERPROOFING, CONCRETE ADMIXTURE & CHEMICAL TREATMENT, REPAIR, REHABILITATION & RE-STRENTHENING OF STRUCTURES
15mm thick plastering of the surface the interior of concrete water tanks with cement mortar in prop 1:4 admixed with modified Styrene Butadiene Rubber based polymer like Sika Latex of Sika India Ltd./Dr. Sealkit Masterbond Latex (Asian Chemicals)/Rheomix 141 of BASF @200gms per bag of cement as specified and directed by the department complete.
OUT SIDE PLASTER.
Cement plaster skirting with cement mortar in prop. 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement including rounding of junctions with floor.
(a) 15 mm thick
STEEL&IRON WORK.
REINFORCEMENT
Supplying,fitting and fixing in position reinforcement bars conforming to relevant I.S Code for R.C.C work/R.B walling including straightening cleaning cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks supports chairs spacers etc.complete(No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate)(upto 1st floor level).
(A)From Primary producer : TATA/ SAIL/Jindal/Shyam steel/Rinl
(i) TMT Corrosion resistant steel(CRS) reinforcement bar
MAN HOLE COVER( Sanitary & water supply) volume -ii
Providing fitting and fixing 450mm dia 90mm thick CI Man hole cover and frame of 38kg weight complete as directed and specified.
CIVIL WORK FOR PROPOSED CONSTRUCTION OF DG PLATFORM
EARTHWORK IN EXCAVATION :
Earth work in excavation for foundation trenches of walls, retaining walls, footings of columns, steps and septic tank etc including refilling (return filling ) the quantity as necessary after completing of work, breaking colds in return filling, dressing, watering and ramming etc.and removal of surplus earth with all lead and lifts as directed and specified in following classifications of soils including bailing out water where necessary as directed and specified.
(A)Up to a depth of 2 m below the existing the ground level.
(a) In ordinary soil
COMPACTED EARTH FILLING
Earth/sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering,ramming etc. complete as directed and specified including payment of land compensation forest royalty, sales taxand other duties and taxs as may be necessary.
(c)With river sand or silt (predominantly non plastic)by truck carriage including loading and unloading.
PLAIN CEMENT CONCRETE WORKS
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, wall, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately).
(a) In prop 1cement :3 sand :6 coarse aggregate by volume
BRICK WORK
Providing brick soiling in foundation and under floor with stone/best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering complete.
(c).Stone soling of thickness 150mm.
Brick work in cement morter with 1st class brick including racking out joints and dewatering if necessary, and curing complete as directed in sub-structure up to plinth level .
(b) In proportion 1:4
REINFORCED CEMENT CONCRETE WORKS
Providing and laying plain/reinforced cement concrete works in prop 1:2:4(1cement:2 coarse sand :4graded stone aggregate,20mm down)including dewatering if necessary,and curing complete but excluding cost of from work and reinforcment for reinforced cement concrete work (form work and reinforcement will be measured and paid separately)
(a)In substructure up to plinth level
(I) Using Mixer Machine
Foundation, Fotting,columns with base,tie and plinth beam, grade beam, pilecap, base slab, retaining walls,walls,walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level.
P) Using admixture, plasticiser etc for air entraining, water reducing purposes including addition of agent for changing normal setting time of concrete as required.
b) M20 grade concrete or Prop. 1:1.5:3
SHUTTERING FORMWORKS
Ordinary Plank
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in:
Flat surface such as soffits of suspended floors,roofs, landing,cantilever slabs,chajjas,balconies and the like.
(a)Floors etc.upto 200mm in thickness.
PLASTERING
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed.
B) On fair side
b) In cement mortar 1:4
CEMENT CONCRETE FLOORING
Cement concrete works in topping 1:1:2 (1cement :1sand :2 graded aggregates on R.C.C floor, tread and rise of steps finished with a floating coat of neat cement using cement slurry for bond @ 2.75 kg.of cement per sq. m. of floor to be laid in panels including curing complete as directed.
(b) 20 mm thick
REINFORCEMENT
Supplying,fitting and fixing in position reinforcement bars conforming to relevant I.S Code for R.C.C work/R.B walling including straightening cleaning cutting and bending to proper shapes and length as per details supplying and binding with 20G annealed black wire and placing in position with proper blocks supports chairs spacers etc.complete(upto 1st floor level).
(i)TATA/SAIL
(i) TMT Corrosion resistant steel (CRS) reiforcement bar
METALLIC/ NON-METALLIC/ EPOXY BASED FLOOR HARDNER/ TOPPINGS
Applying a floating coat of concrete floor hardener Nitoflor Hardtop or Nitoflor Hardtop standard of Fosroc (india) Ltd. over freshly prepared concrete floors followed by sprinkling of Nitoflor Hardtop or Nitoflor Hardtop standard and finishing surface using power trowel as specified and directed by the department (Concrete floor & base courses to be measured and paid separately).
(a) Heavy duty
PRE-CONSTRUCTION ANTI-TERMITE TREATMENT
Pre construction anti - termite treatment by applying in the entire levelled area after plinth filling and before laying floor by applying the emulsion @ 5 (five) litres per square meter of the surface to be spread with light rodding so as to ensure proper absorption by the filled up earth (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete.
a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
Demolishing and Dismantling Works
Internal Electrification of Guest House
A. Wiring
Wiring for light/ fan/ call bell point with 2x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco or Equivalent Make as approved by the Deptt.) in recessed conduit wiring system with 2 mm thick 20mm dia rigid low halogen SFT PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) complete
SP upto 3.00 metre length.
MP upto 6.00 metre length.
LP upto 10.00 metre length.
Wiring to 5 a pin 6 Amps plug point with 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco or Equivalent Make as approved by the Deptt.) in recessed 2 mm thick rigid low halogen SFT PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system including earth continuity with 1.5 sq. mm. cable to third pin of the plug socket etc. as required complete.
SP upto 3.00 metre length.
MP upto 6.00 metre length.
LP upto 10.00 metre length.
Wiring for 5 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system including earth continuity with 2.5 sq. mm cable to the 3rd pin of the socket as required complete with 2 mm thick 20 mm. dia. rigid low halogen SFT PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.)
SP upto 3.00 metre length.
MP upto 6.00 metre length.
LP upto 10.00 metre length.
Wiring for circuit wiring with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system.
With 3 x 1.5 sq. mm. cable in 20 mm dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system.
With 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm. in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
With 2 x 4 sq. mm. + earth continuity with 1x2.5 sq. mm. cable in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
With 2 x 6 sq. mm. + earth continuity with 1x 4 sq. mm. cable in 25 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel or Equivalent Make as approved by the Deptt.) in surface/ recessed PVC 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system.
With 4 x 10 sq. mm. + earth continuity with 2x6 sq. mm. cable in 40 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
With 4 x 16 sq. mm. + earth continuity with 2x10 sq. mm. cable in 40 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
B. SWITCH/SOCKET/PLATE ETC.
Supplying including installation of socket outlet 10/16 Amps 3/5 pin combine shuttered complete , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying including installation of socket outlet 6/10/13 Amps INTERNATIONAL SOCKET , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying with fitting fixing of 16 amp one way modular clip in switch, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying with fitting fixing of 6/10 amp one way modular clip in switch, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) in surface/ recessed system complete as per direction of department.
3 module
6 module
12 module
Supplying including fitting fixing of following MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) front plate of suitable colour as per direction of department.
3 module
6 module
12 module
Supplying with fitting fixing of blank plate single in modular switch system , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
C. FITTING & FIXTURES.
Supplying and fixing of polished Brass Bracket of 18 S.W.G, 25 cm long cast back plate and brass lamp holder complete including connection as approved by the Deptt.)as required Without Lamp
Supplying,installation,testing and Commission of the following indoor Recessed Mounted LED Luminaires complete with all accessories such as driver etc. In the flase ceiling type Armstronng /Gypsum or similar ceiling mouting with necessary support and connection with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the department
Philips lighting luminaire 15 W GreenLED Model BBS170 1xDLED -5000 PSU WH/ BBS170 1xDLED -4000 PSU WH or GreenLED Square ModelBBS175 1xDLED -5000 PSU WH/ BBS175 1xDLED -4000 PSU WH or equivalent as approved by the Deptt.
Philips lighting luminaire 40 W Dayline Model RC240B LED34-6500 PSE-OD WH /RC240B LED34-4000 PSE-OD WH or equivalent as approved by the Deptt.
Supplying,installation,testing and Commission of the following LED lamp as directed by the department
Philips LED bulbs non-dimmable 7 W or equivalent as approved by the Deptt.
D. EARTHING
Installation of earth station with 40mm dia and 4.5 mtr. long GI pipe with necessary GI reducing socket 40mmx20mm size locking arrangement with hinged cover plate, funnel, GI nuts, thorough bolts etc.for putting pipe and refitting with necessary enclosure on the top etc. as required complete.
Extra for using salt 5Kg and charcoal 64 Kg. for pipe earth electrode as required.
Supplying and laying with 6 SWG GI earth wire at 0.50 mtr. below ground level or conductor earth electrode including soldering, excavation work and refitting etc.as required complete.
E.CEILING/EXHAUST FAN
Supplying including fitting fixing of following star rated A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection cable, as approved by the Deptt.s etc. as required complete and as directed by the Department [Without regulator]. (ORIENT PSPO make / Usha make/ CROMPTON make/ Havells/ ATC/ V GAURD make)
Energy efficient 5-star 1200 mm sweep. ORIENT PSPO / Usha / CROMPTON / Havells/ ATC or equivalent make
Supplying including fitting fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department.
Power Flow 225 mm sweep (ORIENT make)
F.AC/GEYSER WORK
Supplying with installation testing and commissioning of Hi -- wall 5 STAR rating non ducted split type air conditioner of the following capacity with cordless remote complete with copper pipe and electrical connection cable, as approved by the Deptt.)up to 5 m between the room unit and out door unit as directed by the department.
2 Ton capacity.
Supplying with fitting and fixing Voltage stabilizer of the following specification complete including making necessary connection as approved, specified and directed by the deptt. (SKYLAND / Vee-Dee / V GUARD / VERTEX/ INDO/ VENUS make)
5.0 KVA Automatic Input 90-280 V Out put 200-240 V
Supplying with fitting and fixing of Single Phase Modular Motor Starter switch of the following specification complete including making necessary connection as specified and directed by the deptt.
Overload Relay Range 16 - 25 Amps in 3 Module
Supplying and fitting fixing of electric storage water heater [Geyser] of VENUS/RAMSON/RACOLD/V Guard/ HAIER or equivalent make) including necessary connection etc. as required complete and as directed by the Department.
Vertical
15 Litre Capacity
G. MCB/MCBDB/RCCB ETC.
Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 surface mounting SPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt.
ABB, Schneider MG, legrand, Hager make)
12 way SPN double door
Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 double door surface mounting TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt.
ABB, Schneider MG, legrand, Hager make)
4way TPN (4+12) double door
6way TPN (4+18) double door
Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.
C Series (Schneider MG, legrand, Hager make)
Supplying with fitting and fixing 30/100/300mA sensitivity 240/415V 50Hz 4P RCCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.
100/300mA sensitivity 4P RCCB (ABB, Schneider MG, legrand, Hager make)
Supplying with fitting and fixing 30/100/300mA sensitivity 240/415V 50Hz DP RCCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.
30mA sensitivity DP RCCB (ABB, Schneider MG, legrand, Hager make)
H.UG CABLE ETC.
Supply and laying of following size Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988, LT armoured U.G. cable laid in pucca flooring, road crossing, drain crossing as per site requirement and partially in air to connection as approved by the Depts. the control switch, through medium duty G.I. pipe (Tata/ Nezone make or equivalent as approved by the Deptt) bend and socket including excavation and refilling the trench and making good damage done as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make)
Core - 3 & 1/2 A2XWY A2XFY
70.00 Sq.mm 3&1/2 Core U.G. cable in 50mm dia medium duty G.I. pipe
ELECTRICAL PANEL AND MCCB
Supplying including installation, commissioning of vermin and dust proof totally enclosed, Phosphatised Powder Painted cubical indoor type floor/wall mounting compartmentalize panel board of size 0.85M X 1.20MX 0.40M made of 16 SWG1.66 m thick C.R. sheet and 35mm X 35mm X 5mm size angle having 4 no legs at the bottom. The panel board is to be erected in 1 : 3 : 6 PCC foundation including brick soling / grouting etc. complete neatly Wiring done with provision for one no 125/160A 4pole MCCB or Switch Fuse Unit as incomer and provision for 4nos DP or TPN out going as specified and directed by the deptt. confirming to IP 43 protection comprising of the following electrical items:
1. 20mm X 3mm 4 strip copper Bus-Bar 1.0 M length each
2. Digital 3 Phase Voltmeter Accuracy class 0.5 - 1 no
3. Digital 3 Phase Ammeter Accuracy class 0.5 - 1 no
4. Pilot Lamp with integral ckt LED 110- 230 V (Red, Yellow,& Blue - 3 no
6. 2 A Slide fuse unit - 3nos
(Incoming & Outgoing Switch Gear of reqd. rating will be measured and paid separately)
Supplying with fitting and fixing panel mounting open execution 25KA 415V 50Hz 4P MCCB (Ics=Icu, adjustable Ir setting 0.7) without enclosure) of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.
25 KA 415V 50 Hz 4P MCCB (Schneider, legrand, Siemens, Indo Asian make)
Supplying with fitting and fixing panel mounting open execution 35/36KA 415V 50Hz 4P MCCB (Ics=Icu, adjustable Ir setting 0.7) without enclosure) of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.
35/36 KA 415V 50 Hz 4P MCCB (Schneider, legrand, Siemens make)
GEN-SET AND CHANGE OVER
Supplying with fitting and fixing Four Pole 415V Front handle operated On Load Change over switch (IP-20 protection powder painted sheet steel enclosure fitted on angle iron frame of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.
ABB, Schneider, legrand, L&T make)
Supplying including installation, testing and commissioning of Air/Water Cooled Diesel Generator set coupled to suitable alternator of 220/415 V, AC, 1/3-Phase 0.8 p.f.(la mounted on a 1) M.S. Fabricated base frame.,2) M.S. fuel tank of required capacity.,3) Residual Silencer.,4) Standard Control Panel.5) Suitable batteries with lead.,5) First fill of lube oil.,6) Acoustic Enclosure complete with all accessories as specified and directed by the department conforming to IS comprising the Technical Specification.. as per manufacturer. (RANGE FROM 5 KVA TO 625 KVA) Kirloskar green/bliss, Leyland, Volvo Penta, Perkinson, Mahindra, Greaves, Escort engine and Kirloskar, Stamford, Leroy somer alternator.
KVA- PHASE- Approx size- Approx Wt - COOLING
62.5 3 3980x1240x1680 1920 Kg A/C
Internal Electrification of Marriage Hall
A. Wiring
Wiring for light/ fan/ call bell point with 2x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco or Equivalent Make as approved by the Deptt.) in recessed conduit wiring system with 2 mm thick 20mm dia rigid low halogen SFT PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) complete
SP upto 3.00 metre length.
MP upto 6.00 metre length.
LP upto 10.00 metre length.
Wiring to 5 a pin 6 Amps plug point with 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco or Equivalent Make as approved by the Deptt.) in recessed 2 mm thick rigid low halogen SFT PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system including earth continuity with 1.5 sq. mm. cable to third pin of the plug socket etc. as required complete.
SP upto 3.00 metre length.
MP upto 6.00 metre length.
LP upto 10.00 metre length.
Wiring for 5 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system including earth continuity with 2.5 sq. mm cable to the 3rd pin of the socket as required complete with 2 mm thick 20 mm. dia. rigid low halogen SFT PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.)
SP upto 3.00 metre length.
MP upto 6.00 metre length.
LP upto 10.00 metre length.
Wiring for circuit wiring with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system.
With 3 x 1.5 sq. mm. cable in 20 mm dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system.
With 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm. in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
With 2 x 4 sq. mm. + earth continuity with 1x2.5 sq. mm. cable in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
With 2 x 6 sq. mm. + earth continuity with 1x 4 sq. mm. cable in 25 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel or Equivalent Make as approved by the Deptt.) in surface/ recessed PVC 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system.
With 4 x 10 sq. mm. + earth continuity with 2x6 sq. mm. cable in 40 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
With 4 x 16 sq. mm. + earth continuity with 2x10 sq. mm. cable in 40 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
B. SWITCH/SOCKET/PLATE ETC.
Supplying including installation of socket outlet 10/16 Amps 3/5 pin combine shuttered complete , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying including installation of socket outlet 6/10/13 Amps INTERNATIONAL SOCKET , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying with fitting fixing of 16 amp one way modular clip in switch, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying with fitting fixing of 6/10 amp one way modular clip in switch, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) in surface/ recessed system complete as per direction of department.
3 module
6 module
12 module
Supplying including fitting fixing of following MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) front plate of suitable colour as per direction of department.
3 module
6 module
12 module
Supplying with fitting fixing of blank plate single in modular switch system , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
C. FITTING & FIXTURES.
Supplying and fixing of polished Brass Bracket of 18 S.W.G, 25 cm long cast back plate and brass lamp holder complete including connection as approved by the Deptt.)as required Without Lamp
Supplying,installation,testing and Commission of the following indoor Recessed Mounted LED Luminaires complete with all accessories such as driver etc. In the flase ceiling type Armstronng /Gypsum or similar ceiling mouting with necessary support and connection with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the department
Philips lighting luminaire 15 W GreenLED Model BBS170 1xDLED -5000 PSU WH/ BBS170 1xDLED -4000 PSU WH or GreenLED Square ModelBBS175 1xDLED -5000 PSU WH/ BBS175 1xDLED -4000 PSU WH or equivalent as approved by the Deptt.
Philips 24 W, Astra Surface & wall mounted LED batten Model BN150W LED20S-6500 PSE OD GR or equivalent as approved by the Deptt.
Supplying,installation,testing and Commission of the following LED lamp as directed by the department
Philips LED bulbs non-dimmable 7 W or equivalent as approved by the Deptt.
D. EARTHING
Installation of earth station with 40mm dia and 4.5 mtr. long GI pipe with necessary GI reducing socket 40mmx20mm size locking arrangement with hinged cover plate, funnel, GI nuts, thorough bolts etc.for putting pipe and refitting with necessary enclosure on the top etc. as required complete.
Extra for using salt 5Kg and charcoal 64 Kg. for pipe earth electrode as required.
Supplying and laying with 6 SWG GI earth wire at 0.50 mtr. below ground level or conductor earth electrode including soldering, excavation work and refitting etc.as required complete.
E.CEILING/EXHAUST FAN
Supplying including fitting fixing of following star rated A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection cable, as approved by the Deptt.s etc. as required complete and as directed by the Department [Without regulator]. (ORIENT PSPO make / Usha make/ CROMPTON make/ Havells/ ATC/ V GAURD make)
Energy efficient 5-star 1200 mm sweep. ORIENT PSPO / Usha / CROMPTON / Havells/ ATC or equivalent make
Supplying including fitting fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department.
Power Flow 225 mm sweep (ORIENT make)
Supplying and fitting fixing of electric storage water heater [Geyser] of VENUS/RAMSON/RACOLD/V Guard/ HAIER or equivalent make) including necessary connection etc. as required complete and as directed by the Department.
Vertical
15 Litre Capacity
G. MCB/MCBDB/RCCB ETC.
Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 surface mounting SPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt.
ABB, Schneider MG, legrand, Hager make)
12 way SPN double door
Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 double door surface mounting TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt.
ABB, Schneider MG, legrand, Hager make)
4way TPN (4+12) double door
6way TPN (4+18) double door
Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.
C Series (Schneider MG, legrand, Hager make)
Supplying with fitting and fixing 30/100/300mA sensitivity 240/415V 50Hz 4P RCCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.
100/300mA sensitivity 4P RCCB (ABB, Schneider MG, legrand, Hager make)
Supplying with fitting and fixing 30/100/300mA sensitivity 240/415V 50Hz DP RCCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.
30mA sensitivity DP RCCB (ABB, Schneider MG, legrand, Hager make)
H.UG CABLE ETC.
Supply and laying of following size Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988, LT armoured U.G. cable laid in pucca flooring, road crossing, drain crossing as per site requirement and partially in air to connection as approved by the Depts. the control switch, through medium duty G.I. pipe (Tata/ Nezone make or equivalent as approved by the Deptt) bend and socket including excavation and refilling the trench and making good damage done as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make)
Core - 3 & 1/2 A2XWY A2XFY
70.00 Sq.mm 3&1/2 Core U.G. cable in 50mm dia medium duty G.I. pipe
ELECTRICAL PANEL AND MCCB
Supplying including installation, commissioning of vermin and dust proof totally enclosed, Phosphatised Powder Painted cubical indoor type floor/wall mounting compartmentalize panel board of size 0.85M X 1.20MX 0.40M made of 16 SWG1.66 m thick C.R. sheet and 35mm X 35mm X 5mm size angle having 4 no legs at the bottom. The panel board is to be erected in 1 : 3 : 6 PCC foundation including brick soling / grouting etc. complete neatly Wiring done with provision for one no 125/160A 4pole MCCB or Switch Fuse Unit as incomer and provision for 4nos DP or TPN out going as specified and directed by the deptt. confirming to IP 43 protection comprising of the following electrical items:
1. 20mm X 3mm 4 strip copper Bus-Bar 1.0 M length each
2. Digital 3 Phase Voltmeter Accuracy class 0.5 - 1 no
3. Digital 3 Phase Ammeter Accuracy class 0.5 - 1 no
4. Pilot Lamp with integral ckt LED 110- 230 V (Red, Yellow,& Blue - 3 no
6. 2 A Slide fuse unit - 3nos
(Incoming & Outgoing Switch Gear of reqd. rating will be measured and paid separately)
Supplying including installation, commissioning of vermin and dust proof totally enclosed, Phosphatised Powder Painted cubical indoor type floor/wall mounting compartmentalize panel board of size 0.85M X 1.20MX 0.40M made of 16 SWG1.66 m thick C.R. sheet and 35mm X 35mm X 5mm size angle having 4 no legs at the bottom. The panel board is to be erected in 1 : 3 : 6 PCC foundation including brick soling / grouting etc. complete neatly Wiring done with provision for one no 250A 4pole MCCB or Switch Fuse Unit as incomer and provision for 4nos DP or TPN out going as specified and directed by the deptt. confirming to IP 43 protection comprising of the following electrical items:
1. 20mm X 5mm4 strip copper Bus-Bar 1.0 M length each
2. Digital 3 Phase Voltmeter Accuracy class 0.5 - 1 no
3. Digital 3 Phase Ammeter Accuracy class 0.5 - 1 no
4. Pilot Lamp with integral ckt LED 110- 230 V (Red, Yellow,& Blue - 3 no
6. 2 A Slide fuse unit - 3nos
(Incoming & Outgoing Switch Gear of reqd. rating will be measured and paid separately)
Supplying with fitting and fixing panel mounting open execution 25KA 415V 50Hz 4P MCCB (Ics=Icu, adjustable Ir setting 0.7) without enclosure) of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.
25 KA 415V 50 Hz 4P MCCB (Schneider, legrand, Siemens, Indo Asian make)
Supplying with fitting and fixing panel mounting open execution 35/36KA 415V 50Hz 4P MCCB (Ics=Icu, adjustable Ir setting 0.7) without enclosure) of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.
35/36 KA 415V 50 Hz 4P MCCB (Schneider, legrand, Siemens make)
GEN SET AND CHANGE OVER
Supplying with fitting and fixing Four Pole 415V Front handle operated On Load Change over switch (IP-20 protection powder painted sheet steel enclosure fitted on angle iron frame of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.
ABB, Schneider, legrand, L&T make)
Supplying including installation, testing and commissioning of Air/Water Cooled Diesel Generator set coupled to suitable alternator of 220/415 V, AC, 1/3-Phase 0.8 p.f.(la mounted on a 1) M.S. Fabricated base frame.,2) M.S. fuel tank of required capacity.,3) Residual Silencer.,4) Standard Control Panel.5) Suitable batteries with lead.,5) First fill of lube oil.,6) Acoustic Enclosure complete with all accessories as specified and directed by the department conforming to IS comprising the Technical Specification.. as per manufacturer. (RANGE FROM 5 KVA TO 625 KVA) Kirloskar green/bliss, Leyland, Volvo Penta, Perkinson, Mahindra, Greaves, Escort engine and Kirloskar, Stamford, Leroy somer alternator.
KVA- PHASE- Approx size- Approx Wt - COOLING
100 3 3200x1300x1805 1950 Kg W/C
Internal Electrification of Out Door toilet Block
A. Wiring
Wiring for light/ fan/ call bell point with 2x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco or Equivalent Make as approved by the Deptt.) in recessed conduit wiring system with 2 mm thick 20mm dia rigid low halogen SFT PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) complete
SP upto 3.00 metre length.
MP upto 6.00 metre length.
LP upto 10.00 metre length.
Wiring for circuit wiring with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system.
With 3 x 1.5 sq. mm. cable in 20 mm dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system.
With 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm. in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
With 2 x 6 sq. mm. + earth continuity with 1x 4 sq. mm. cable in 25 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
B. SWITCH/SOCKET/PLATE ETC.
Supplying with fitting fixing of 6/10 amp one way modular clip in switch, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) in surface/ recessed system complete as per direction of department.
6 module
Supplying including fitting fixing of following MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) front plate of suitable colour as per direction of department.
6 module
Supplying with fitting fixing of blank plate single in modular switch system , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
C. FITTING & FIXTURES.
Supplying and fixing of polished Brass Bracket of 18 S.W.G, 25 cm long cast back plate and brass lamp holder complete including connection as approved by the Deptt.)as required Without Lamp
Supplying,installation,testing and Commission of the following indoor Recessed Mounted LED Luminaires complete with all accessories such as driver etc. In the flase ceiling type Armstronng /Gypsum or similar ceiling mouting with necessary support and connection with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the department
Philips lighting luminaire 15 W GreenLED Model BBS170 1xDLED -5000 PSU WH/ BBS170 1xDLED -4000 PSU WH or GreenLED Square ModelBBS175 1xDLED -5000 PSU WH/ BBS175 1xDLED -4000 PSU WH or equivalent as approved by the Deptt.
Supplying,installation,testing and Commission of the following LED lamp as directed by the department
Philips LED bulbs non-dimmable 7 W or equivalent as approved by the Deptt.
D. EARTHING
Installation of earth station with 40mm dia and 4.5 mtr. long GI pipe with necessary GI reducing socket 40mmx20mm size locking arrangement with hinged cover plate, funnel, GI nuts, thorough bolts etc.for putting pipe and refitting with necessary enclosure on the top etc. as required complete.
Extra for using salt 5Kg and charcoal 64 Kg. for pipe earth electrode as required.
Supplying and laying with 6 SWG GI earth wire at 0.50 mtr. below ground level or conductor earth electrode including soldering, excavation work and refitting etc.as required complete.
E.EXHAUST FAN
Supplying including fitting fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department.
Power Flow 225 mm sweep (ORIENT make)
G. MCB/MCBDB/RCCB ETC.
Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 surface mounting SPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt.
ABB, Schneider MG, legrand, Hager make)
12 way SPN double door
Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.
C Series (Schneider MG, legrand, Hager make)
Supplying with fitting and fixing 30/100/300mA sensitivity 240/415V 50Hz DP RCCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.
30mA sensitivity DP RCCB (ABB, Schneider MG, legrand, Hager make)
Internal Electrification of Open Air Stage and Security Room
A. Wiring
Wiring for light/ fan/ call bell point with 2x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco or Equivalent Make as approved by the Deptt.) in recessed conduit wiring system with 2 mm thick 20mm dia rigid low halogen SFT PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) complete
SP upto 3.00 metre length.
MP upto 6.00 metre length.
LP upto 10.00 metre length.
Wiring to 5 a pin 6 Amps plug point with 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco or Equivalent Make as approved by the Deptt.) in recessed 2 mm thick rigid low halogen SFT PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system including earth continuity with 1.5 sq. mm. cable to third pin of the plug socket etc. as required complete.
SP upto 3.00 metre length.
MP upto 6.00 metre length.
LP upto 10.00 metre length.
Wiring for 5 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system including earth continuity with 2.5 sq. mm cable to the 3rd pin of the socket as required complete with 2 mm thick 20 mm. dia. rigid low halogen SFT PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.)
SP upto 3.00 metre length.
MP upto 6.00 metre length.
LP upto 10.00 metre length.
Wiring for circuit wiring with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system.
With 3 x 1.5 sq. mm. cable in 20 mm dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system.
With 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm. in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
With 2 x 4 sq. mm. + earth continuity with 1x2.5 sq. mm. cable in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel or Equivalent Make as approved by the Deptt.) in surface/ recessed PVC 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system.
With 4 x 10 sq. mm. + earth continuity with 2x6 sq. mm. cable in 40 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
B. SWITCH/SOCKET/PLATE ETC.
Supplying including installation of socket outlet 10/16 Amps 3/5 pin combine shuttered complete , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying including installation of socket outlet 6/10/13 Amps INTERNATIONAL SOCKET , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying with fitting fixing of 16 amp one way modular clip in switch, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying with fitting fixing of 6/10 amp one way modular clip in switch, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) in surface/ recessed system complete as per direction of department.
3 module
6 module
12 module
Supplying including fitting fixing of following MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) front plate of suitable colour as per direction of department.
3 module
6 module
12 module
Supplying with fitting fixing of blank plate single in modular switch system , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
C. FITTING & FIXTURES.
Supplying and fixing of polished Brass Bracket of 18 S.W.G, 25 cm long cast back plate and brass lamp holder complete including connection as approved by the Deptt.)as required Without Lamp
Supplying,installation,testing and Commission of the following indoor Recessed Mounted LED Luminaires complete with all accessories such as driver etc. In the flase ceiling type Armstronng /Gypsum or similar ceiling mouting with necessary support and connection with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the department
Philips lighting luminaire 15 W GreenLED Model BBS170 1xDLED -5000 PSU WH/ BBS170 1xDLED -4000 PSU WH or GreenLED Square ModelBBS175 1xDLED -5000 PSU WH/ BBS175 1xDLED -4000 PSU WH or equivalent as approved by the Deptt.
Philips 24 W, Astra Surface & wall mounted LED batten Model BN150W LED20S-6500 PSE OD GR or equivalent as approved by the Deptt.
Supplying,installation,testing and Commission of the following LED lamp as directed by the department
Philips LED bulbs non-dimmable 7 W or equivalent as approved by the Deptt.
D. EARTHING
Installation of earth station with 40mm dia and 4.5 mtr. long GI pipe with necessary GI reducing socket 40mmx20mm size locking arrangement with hinged cover plate, funnel, GI nuts, thorough bolts etc.for putting pipe and refitting with necessary enclosure on the top etc. as required complete.
Extra for using salt 5Kg and charcoal 64 Kg. for pipe earth electrode as required.
Supplying and laying with 6 SWG GI earth wire at 0.50 mtr. below ground level or conductor earth electrode including soldering, excavation work and refitting etc.as required complete.
E.CEILING/EXHAUST FAN
Supplying including fitting fixing of following star rated A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection cable, as approved by the Deptt.s etc. as required complete and as directed by the Department [Without regulator]. (ORIENT PSPO make / Usha make/ CROMPTON make/ Havells/ ATC/ V GAURD make)
Energy efficient 5-star 1200 mm sweep. ORIENT PSPO / Usha / CROMPTON / Havells/ ATC or equivalent make
Supplying including fitting fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department.
Power Flow 225 mm sweep (ORIENT make)
G. MCB/MCBDB/RCCB ETC.
Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 double door surface mounting TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt.
ABB, Schneider MG, legrand, Hager make)
4way TPN (4+12) double door
Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.
C Series (Schneider MG, legrand, Hager make)
Supplying with fitting and fixing 30/100/300mA sensitivity 240/415V 50Hz 4P RCCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.
100/300mA sensitivity 4P RCCB (ABB, Schneider MG, legrand, Hager make)
External electrification including installation of 200KVA transformer sub station
Supplying, installation, testing and commissioning of the following capacity Copper wound out door type sub-station complete with transformer,HT/LT side fittings and all other following accessories as required complete including payment of ASEB's supervision charge, labour charge, cost of ASEB's materials like metering equipment, CT/PT set etc.(excluding payment of load security),arrangement of charging approval of sub-station from Chief Electrical inspectorate and consisting of the followings:
35.1.5) 200KVA,50Hz,11/.433KV oil filled transformer with off circuit tap change
Installation of earth station with 40mm dia and 4.5 mtr. long GI pipe with necessary GI reducing socket 40mmx20mm size locking arrangement with hinged cover plate, funnel, GI nuts, thorough bolts etc.for putting pipe and refitting with necessary enclosure on the top etc. as required complete.
Extra for using salt 5Kg and charcoal 64 Kg. for pipe earth electrode as required.
Supplying and laying with 6 SWG GI earth wire at 0.50 mtr. below ground level or conductor earth electrode including soldering, excavation work and refitting etc.as required complete.
Supplying including installation of the Octagonal poles shall be designed to withstand the maximum wind speed of 169 km/hr. The top loading i.e. area and weight of fixtures are to be considered to calculate maximum deflection of the poles and the same shall meet the requirement of BS:5649 Part VI 1982. The pole shaft shall have octagonal cross section and shall be continuously tapered with single longitudinal welding. There shall not be any circumferential welding of the pole shaft. The welding of the pole shaft shall be done by Submerged Welding process. All octagonal pole shafts shall be provided with the rigid flange plate of suitable thickness with provision for fixing 4 foundation bolts. The base plate shall be fillet welded to the pole shaft at two locations i.e. from inside and outside. The welding shall be done as per process approved by Third Party Inspection agency. (BAJAJ/ PHILIPS/ VALMONT/ PARUTHI ENGR/Nezone make)
Pole Type BOP or equivalent-4030, Height 3 The materials of the pole as follows : Conforming to grade S355JO Conforming to grade S355JO , Base Plate Fe 410 Conforming to IS 226/ IS 2062, Foundation Bolts :- 6.8 Gr. As per IS 1367, Pole Sections The Octagonal Poles shall be in single piece with single longitudinal welding join, Galvanization The poles shall be hot dip galvanized as per IS 2629 / IS 2633 / IS 4759 standards with average coating thickness of 65 micron. The galvanizing shall be done in single dipping.
Door opening The Octagonal poles shall have door of approximate 500 mm length at the elevation of 500 mm from the base plate. The door shall be vandal resistance and shall be weather proof to ensure safety of inside connection as approved by the Depts.. The door shall be flush with the exterior surface and shall have suitable locking arrangement. The pole shall be adequately strengthened at the location of the door compensate for the loss in section. There shall also be suitable arrangement for the purpose of earthing, Smart pack Junction box with 6 MCB & Terminals for mounting inside base compartment of Pole., Top Dia. (A/ 70 Bottom Dia. (A/ 130 Sheet Thickness 3, Base Plate , Dimensions :- (L x B x 200 x 200 x 12, Foundation Bolt , Bolt Size:- (no. x dia.) 4 x 16 Dia Pitch Circle Dia. (PC 200, Bolt Length 450, Projected Bolt Length 80, Anchor plate thickness:- 4 mm , Pole Foundation:- The octagonal poles shall be bolted on a pre- cast foundation with a set of four foundation bolts for greater rigidity. Foundation:- The foundation shall be done with, ( Earth work 2.04 cubic Meters, RCC 1:1.5 : 3 proportion 0.65 cubic metres, Steel 22.43 Kg, Shuttering 4.32 square metres. = 22.43 Kg.
Pole Type BOP or equivalent-4030, Height 4 The materials of the pole as follows : Conforming to grade S355JO Conforming to grade S355JO , Base Plate Fe 410 Conforming to IS 226/ IS 2062, Foundation Bolts :- 6.8 Gr. As per IS 1367, Pole Sections The Octagonal Poles shall be in single piece with single longitudinal welding join, Galvanization The poles shall be hot dip galvanized as per IS 2629 / IS 2633 / IS 4759 standards with average coating thickness of 65 micron. The galvanizing shall be done in single dipping. Door opening The Octagonal poles shall have door of approximate 500 mm length at the elevation of 500 mm from the base plate. The door shall be vandal resistance and shall be weather proof to ensure safety of inside connection as approved by the Depts.. The door shall be flush with the exterior surface and shall have suitable locking arrangement. The pole shall be adequately strengthened at the location of the door compensate for the loss in section. There shall also be suitable arrangement for the purpose of earthing, Smart pack Junction box with 6 MCB & Terminals for mounting inside base compartment of Pole., Top Dia. (A/ 70 Bottom Dia. (A/ 130 Sheet Thickness 3, Base Plate , Dimensions :- (L x B x 200 x 200 x 12, Foundation Bolt , Bolt Size:- (no. x dia.) 4 x 16 Dia Pitch Circle Dia. (PC 200, Bolt Length 450, Projected Bolt Length 80, Anchor plate thickness:- 4 mm , Pole Foundation:- The octagonal poles shall be bolted on a pre- cast foundation with a set of four foundation bolts for greater rigidity. Foundation:- The foundation shall be done with, ( Earth work 2.04 cubic Meters, RCC 1:1.5 : 3 proportion 0.65 cubic metres, Steel 22.43 Kg, Shuttering 4.32 square metres. = 22.43 Kg.
Pole Type BOP or equivalent-7030 Height 7m The materials of the pole as follows : Conforming to grade S355JO Conforming to grade S355JO , Base Plate Fe 410 Conforming to IS 226/ IS 2062, Foundation Bolts:- 6.8 Gr. As per IS 1367, Pole Sections :- The Octagonal Poles shall be in single piece with single longitudinal welding join, Galvanization :- The poles shall be hot dip galvanized as per IS 2629 / IS 2633 / IS 4759 standards with average coating thickness of 65 micron. The galvanizing shall be done in single dipping. Door opening :- The Octagonal poles shall have door of approximate 500 mm length at the elevation of 500 mm from the base plate. The door shall be vandal resistance and shall be weather proof to ensure safety of inside connection as approved by the Depts.. The door shall be flush with the exterior surface and shall have suitable locking arrangement. The pole shall be adequately strengthened at the location of the door compensate for the loss in section. There shall also be suitable arrangement for the purpose of earthing, Smart pack Junction box with 6 MCB & Terminals for mounting inside base compartment of Pole. Top Dia. (A/ 70mm Bottom Dia. (A/ 130mm , Sheet Thickness 3mm , Base Plate dimensions :- (L x B x 220 x 220 x 12, Foundation Bolt , Bolt Size :- (no. x dia.) 4 x 20 Dia, Pitch Circle Dia. (PC 205 Bolt Length 750, Projected Bolt Length 100mm, Anchor plate thickness:- 4 mm , Pole Foundation :- The octagonal poles shall be bolted on a pre- cast foundation with a set of four foundation bolts for greater rigidity. Foundation:- The foundation shall be done with ( Earth work:- 2.04 cubic Meters.RCC :- 1:1.5 : 3 proportion 0.65 cubic metres. Steel :- 22.43 Kg. Shuttering :- 4.32 square metres. = 22.43 Kg.
3.12 Supplying including installation, connection cable, as approved by the Deptt.)with 2x2.5 sqmm copper FR CABLE, testing and commissioning of following post top lantern/ WALL LIGHT on existing pole/ Structure including lamp, driver, ballast as required complete as directed and specified by the deptt.
3.13 Supplying including installation, connection cable, as approved by the Deptt.)with 2x2.5 sqmm copper FR CABLE, testing and commissioning of following BOLLARD LIGHT on Cement concrete foundation including lamp, driver, ballast as required complete as directed and specified by the deptt.
Supplying including installation, connection cable, as approved by the Deptt. with 2x2.5 sqmm copper FR CABLE, testing and commissioning of the following street light on existing pole/ Structure including lamp, driver, ballast as required complete as directed and specified by the deptt.
Philips lighting luminaire 10w GreenLine Smart Model BRP022 LED 10 CW MR S1 PSU GR or equivalent as approved by the Deptt.
Philips lighting luminaire 20w GreenLine Smart Model BRP022 LED 21 CW MR S1 PSU GR or equivalent as approved by the Deptt.
Supplying including installation with required bracket, connection cable, as approved by the Deptt. with 2x2.5 sqmm copper FR CABLE, testing and commissioning of the following street light/ FLOOD LIGHT on existing pole/ Structure including lamp, driver, ballast as required complete as directed and specified by the deptt.
Philips Flood lighting luminaire 210W with high power LED and unique flood optics to ensure uniform distribution Model BVP410 LED 210 CW HE NB FG S3 XT or equivalent as approved by the Deptt.
Supplying including installation, commissioning of vermin and dust proof totally enclosed, Phosphatised Powder Painted cubical indoor type floor/wall mounting compartmentalize panel board of size 1.45M X 1.55MX 0.40M made of 16 SWG1.66 m thick C.R. sheet and 35mm X 35mm X 5mm size angle having 4 no legs at the bottom. The panel board is to be erected in 1 : 3 : 6 PCC foundation including brick soling / grouting etc. complete neatly Wiring done with provision for one no 315A 4pole MCCB or Switch Fuse Unit as incomer and provision for 8nos DP or TPN out going as specified and directed by the deptt. confirming to IP 43 protection comprising of the following electrical items:
1. 30mm X 5mm 4 strip copper Bus - Bar 1.45 M length each
i 20mm X 3mm 4 strip copper Bus-Bar 0.5M each 8sets
2. Digital 3 Phase Voltmeter Accuracy class 0.5 - 1 no
3. Digital 3 Phase Ammeter Accuracy class 0.5 - 1 no
4. Pilot Lamp with integral ckt LED 110- 230 V (Red, Yellow,& Blue - 3 no
6. 2 A Slide fuse unit - 3nos
(Incoming & Outgoing Switch Gear of reqd. rating will be measured and paid separately)
Supplying including installation, commissioning of vermin and dust proof totally enclosed, Phosphatised Powder Painted cubical outdoor type double door, floor mounting compartmentalize panel board of size 1.35M X 1.50MX 0.40M made of 16 SWG1.66 m thick C.R. sheet and 35mm X 35mm X 5mm size angle having 4 no legs at the bottom and C.R. sheet roofing on the top complete painting with 2 coats of Red Oxide metal primer and 2 coats of enamel paint. The panel board is to be erected in 1 : 3 : 6 PCC foundation including excavation of trench and brick soling etc. complete neatly Wiring done with provision for one no 125/160A 4pole MCCB or Switch Fuse Unit as incomer and provision for 8nos DP or TPN out going as specified and directed by the deptt. confirming to IP 65 protection comprising of the following electrical items:
1. 20mm X 3mm4 strip copper Bus-Bar 1.4 M length each
2. Digital 3 Phase Voltmeter Accuracy class 0.5 - 1 no
3. Digital 3 Phase Ammeter Accuracy class 0.5 - 1 no
4. Pilot Lamp with integral ckt LED 110- 230 V (Red, Yellow,& Blue - 3 no
6. 2 A Slide fuse unit - 3nos
(Incoming & Outgoing Switch Gear of reqd. rating will be measured and paid separately)
Supplying and installation and commissioning of vermin and dust proof totally enclosed double door cubical type compartmental floor mounting panel board of size 1.20 m ×1.00 m ×0.50 m made of 16 SWG1.66mm) thick CR sheet and 35 mm × 35 mm
× 6 mm size angle and 35 mm ×6 mm flat iron having 4 nos legs at the bottom and G.I. Sheet reefing on the top complete painting with 2 coats of red oxide metal primer and 2 coats of enameled paint. The panel board is to be erected in 1:3:6 RCC pole foundation including excavation of trench and brick soling etc. complete neatly internal wiring done as specified and directed by the department comprising of the following electrical items.
1. 40 Amp 4 pole 415 Volt 50 Hz MCCB as incomer - 1 no
2. 32 Amp 2 pole open execution with HBC fuse SDFU unit as outgoing - 3 nos.
3. 25 mm × 5 mm size 4 strip copper Bus-Bar- 1 set
4. 40 Amp 4 pole ON-OFF poser contactor - 1 No.
5. Surface mounting timer switch - 1 No.
6. 63 Amp bakelite HBC fuse kit-kat - 3 Nos
Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 surface mounting SPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt.
Schneider neo break, C&S, Havells, INDOASIAN, HPL or equivalent as approved by the Deptt.)make)
6 way SPN double door
Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 double door surface mounting TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt.
ABB, Schneider MG, legrand, Hager make)
4 way TPN (4+12) double door
Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.
C Series (Schneider MG, legrand, Hager make)
Supplying with fitting and fixing DP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.
C Series (ABB, Schneider MG, legrand, Hager make)
Supplying with fitting and fixing 4P 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.
C Series (ABB, Schneider MG, legrand, Hager make)
Supplying with fitting and fixing panel mounting open execution 25KA 415V 50Hz 4P MCCB (Ics=Icu, adjustable Ir setting 0.7) without enclosure) of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.
25 KA 415V 50 Hz 4P MCCB (Schneider, legrand, Siemens, Indo Asian make)
Supplying with fitting and fixing panel mounting open execution 35/36KA 415V 50Hz 4P MCCB (Ics=Icu, adjustable Ir setting 0.7) without enclosure) of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.
35/36 KA 415V 50 Hz 4P MCCB (Schneider, legrand, Siemens make)
Supplying with fitting and fixing Four Pole 415V Front handle operated On Load Change over switch (IP-20 protection powder painted sheet steel enclosure fitted on angle iron frame of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.
ABB, Schneider, legrand, L&T make)
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts
(Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system.
With 2 x 4 sq. mm. + earth continuity with 1x2.5 sq. mm. cable in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed PVC 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system.
With 4 x 10 sq. mm. + earth continuity with 2x6 sq. mm. cable in 40 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Supply and laying of following size Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988, LT armoured U.G. cable laid in pucca flooring, road crossing, drain crossing as per site requirement and partially in air to connection as approved by the Depts. the control switch, through medium duty G.I. pipe (Tata/ Nezone make or equivalent as approved by the Deptt) bend and socket including excavation and refilling the trench and making good damage done as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make)
Core - 3 A2XWY A2XFY
6.00 Sq.mm 3 Core U.G. cable in 32mm dia medium duty G.I. pipe
10.00 Sq.mm 3 Core U.G. cable in 32mm dia medium duty G.I. pipe
Core - 3 & 1/2 A2XWY A2XFY
50.00 Sq.mm 3&1/2 Core U.G. cable in 50mm dia medium duty hot dip galvanised pipe (AKG or equivalent as approved by the Deptt.)
120.00 Sq.mm 3&1/2 Core U.G. cable in 65 mm dia medium duty hot dip galvanised pipe (AKG or equivalent as approved by the Deptt.)
Supplying including installation, testing and commissioning of Air/Water Cooled Diesel Generator set coupled to suitable alternator of 220/415 V, AC, 1/3-Phase 0.8 p.f.(la mounted on a 1) M.S. Fabricated base frame.,2) M.S. fuel tank of required capacity.,3) Residual Silencer.,4) AMF Control Panel.5) Suitable batteries with lead.,5) First fill of lube oil.,6) Acoustic Enclosure complete with all accessories as specified and directed by the department conforming to IS comprising the Technical Specification.. as per manufacturer. (RANGE FROM 5 KVA TO 625 KV . Kirloskar green/bliss, Leyland, Volvo Penta, Perkinson, Mahindra, Greaves, Escort engine and Kirloskar, Stamford, Leroy somer or equivalent alternator.
40 3 3130x1100x1680 1440 Kg A/C
Supplying including installation, connection as approved by the Deptt., testing and commissioning of SUBMERSIBLE PUMP SET 3 (Three Phase) with steel cable rope and submersible cable complete as directed and specified by the deptt.
Three phase Submersible motor pump set (Texmo / Crompton Greaves/ Aquatic/ CRI/ V-Guar suitable for 100 mm bore well and above. 3 HP STAGE 7 to 40 with MCB controlled Submersible motor pump set control panel.
Construction of 3 phase 11 KV Line on 8.5 m PSC Pole using AAA Raccoon conductor 7/3.81mm with T cross arm average span 70m.
Payment of load security, meter security etc.
MUSEUM BUILDING AT MERGHAR
GROUND FLOOR
DEMOLISHED AND DISMANTLING
EARTHWORK
EXCAVATION :
Earth work in excavation for foundation trenches of walls, retaining walls, footings of columns, steps and septic tank etc including refilling ( return filling ) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc.and removal of surplus earth with all lead and lifts as directed and specified in the following classifications of soils including bailing out water where necessary as directed and specified.
(A) Up to a depth of 2.00 m below the existing ground level.
(b) In hard/ dense soil
PLINTH FILLING:
Earth/sand filling in plinth in layers not more than 150 mm thick including necessary carriage, watering,ramming etc. complete as directed and specified including payment of land compensation forest royalty, sales taxe and other duties and taxes as may be necessary.
© With river sand or silt (predominantly non plastic)by truck carriage including loading and unloading.
CEMENT CONCRETE WORKS
PLAIN CEMENT CONCRETE WORKS
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, wall, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where neccessary shall be measured and paid separately).
(a) In prop 1 cement : 3 sand : 6 coarse aggregate by volume
Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg.of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed.
REINFORCED CEMENT CONCRETE WORKS
Providing and laying plain/reinforced cement concrete works including dewatering if necessary,and curing complete but excluding cost of from work and reinforcment for reinforced cement concrete work ( form work and reinforcement will be measured and paid separately)
Using mixture machine
(A)In sub-structure up to plinth level
Foundation, Fotting,columns with base,tie and plinth beam, grade beam, pilecap, base slab, retaining walls,walls,walls of septic tank, inspection pit and the like and other works not less than 100 mm thick up to plinth level.
P) Using admixture, plasticiser etc for air entraining, water reducing purposes including addition of agent for changing normal setting time of concrete as required.
b) M 20 grade concrete or Prorp.1:1.5:3
(B)In super structure from plinth level upto 1st floor level.
(ii)Columns, pillar, posts, struts, suspended floor, roof, landing, shelf, and support, balcony, lintel, sill band beam, girder, bressumer, cantilever, staircase(exceptspiral staircase and landing) including preparing the top surface and finishing of nosing.
P) Using admixture, plasticiser etc
b) M20 Grade concrete or prop 1:1.5:3
SHUTTERING /FORM WORKS
PLYBOARD SHUTTERING
Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in:
Columns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical face
Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties.
(a) For depth not exceeding 1.0M.
Flat Surfaces such as soffits of suspended floors, roofs, landings and the like.
BRICK WORKS
Providing brick soiling in foundation and under floor with stone/best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering complete.
(a).Brick on flat soling.
Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed.
(I) In Sub-structure upto plinth level including dewatering if necessary
(b) In proportion 1:4.
100mm thick wall using Cellular Light Weight concrete block of Size 500x200x100mm conforming to IS-2185 Pt-3 or pt-4 in cement mortar of proportion 1: 5 including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding rod is to be provided at every 3 course interval and will be measured and paid separately)
FALSE CEILING
Supplying, fitting, fixing and painting where necessary (one coat primer and two coats of paint) M/ F suspended ceiling which includes G.I. perimeter channels of size 0.55mm thick (having one flange of 20mm and another flange of 30mm and a web of 27mm) along with perimeter of ceiling, screw fixed to brick wall/ partition with the help of nylon sleeves and screws, at 610mm c/c. Then suspending G.I. intermediate channels of size 45mm (0.9mm thick with two equal flanges of 15mm each) from the soffit at 1220mm c/c with ceiling angle of width 5mmx10mmx0.55mm thick fixed to soffit with G.I.cleat and steel expansion fasteners. Ceiling section of 0.55mm thickness having knurled web of 51.5mm and two equal flanges of 26mm each with lips of 10.5mm are then fixed to the intermediate channel with the help of connecting clip and in direction perpendicular to the intermediate channel at 457mm c/c, 9.5mm/ 12.5mm thick Gypboard.
False ceiling (Light Duty) with Moisture Resistant Board (conforming to IS:2095-1982) is then screw fixed to ceiling section with 25mm long drywall screws at 230mm c/c. Screw fixing is done mechanically either with screw driver or drilling machine with suitable attachment. Finally, the boards are to be jointed and finished so as to have a flush look which includes filling and finishing the tapered and square edges of the boards with jointing compound, joint paper tape and two coats of drywall topcoat suitable for Gypboard complete at all levels as specified and directed. (For light fittings, providing opening for doors, window, ventilators etc., cut out made with frame of perimeter channel supported suitably to be measured and paid separately as and where necessary).
12.5mm MRB
FLOOR FINISHED
Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department)
a) Normal range Somany/ Orient/Nitco /Varmora/Jhonson Make
ii) Of size 600mmx600mm and above
PLASTERING
10 mm thick Cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed.
b) In cement mortar 1:4
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed.
A) On rough side
b) In cement mortar 1:4
B) On fair side
b) In cement mortar 1:4
Extra over item no 6.2.1 to 6.2.3 for plastering on celling and soffits of stairs up to 1st floor level (instead of plastering on walls) including curing complete as directed.
Water Proofing Plastering
15mm thick plastering of the interior surface of concrete water tanks with cement mortar in prop 1:4 admixed with modified Styrene Butadiene Rubber based polymer like Sika Latex of Sika India Ltd./Dr. Sealkit Masterbond Latex (Asian Chemicals)/Rheomix 141 of BASF @ 200gms per bag of cement as specified and directed by the department complete.
WALL PUTTY
Providing two coats of acrylic water based wall putty/ wall filler of Asian Paints/ Berger/ Dulux over concrete/ cement plaster/ brick walls and ceilings both internal and external after removing all the loosely adhering material from the wall/ ceiling surface with the help of emery stone, putty blade or wire brush, moistening the wall with the help of sufficient quantity of clear water as specified and directed by the department.
WALL PAINTING
CEMENT PRIMER
a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
Wall painting (two coats) with acrylic emulsion paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth.
(a).Acrylic Emulsion Paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac)
EXTEROR PAINTING
SPECIAL WATHER PROOF COLOURING
Finishing old/ new wall with water proofing weather coat smooth anti-fungal exterior painting of Apex brand of Asian Paints and of required shade after cleaning and clearing the surface etc. including scaffolding complete as directed at all levels (two coats)
PAINTING ON STEEL AND OTHER METAL SURFACE
Applying primary coat over new steel and other metal surface over 100m in width or girth after preparing the surface by throughly cleaning oil,grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper.
Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter.
(i).Surfaces over 100mm in width or girth.
b). High gloss (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
PAINTING ON WOOD AND WOOD WOOD BASED SURFACES
Applying priming coat over new wood and wood based surfaces over 100mm in girth/width after and including preparing the surface by throughly cleaning oil, grease, dirt and other foreign matter, sand papering and knotting.
(a). With ready mixed paint , Wood primer (pink)
Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surfaces of all dirt, dust and other foreign matter sand papering and stopping.
(i).Surfaces over 100mm in width or girth.
b). High gloss (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
REINFORCEMENT
Supplying,fitting and fixing in position reinforcement bars conforming to relevant I.S Code for R.C.C work/R.B walling including straightening cleaning cutting and bending to proper shapes and length as per details supplying and binding with 20G annealed black wire and placing in position with proper blocks supports chairs spacers etc.complete.(No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they included in the rate.)(upto 1st fl level).
a) From Primary Producer: TATA/SAIL/Jindal steel/Shyam steel/RINL
(i) TMT Corrosion resistant steel (CRS) reiforcement bar
COLLAPSIBLE / ROLLING SHUTTERS
Providing and fixing in position collapsible M.S. shutters with vertical channels 20mmx10mmx2mm braced with flat iron diagonals 20mmx5mm size with top and bottom rails of T-iron 40mmx40mmx6mm with 38mm dia steel pulleys complete with bolts and nuts, locking arrangements, stoppers, handles including applying a priming coat of red lead paint.
GRILL WORKS
Providing,fitting and fixing M.S grill of required pattern for windows/clerestory windows/opening with M.S flats at required spacing in frame all round,square or round M.S bars with round headed bolts and nuts or screws.
I. Plain grill
© Fixed to Brickwork/P.C.C/R.C.C
CHOWKATH
Providing wood work in frame (chowkaths) of doors, windows, clerestory windows and other similar works wrought, framed and fixed in position in contact with C.C or brick masonry wall including supplying, fitting and fixing with M.S. hold fast (40mmx3mmx250mm) as per design embeded in cement concrete block in proportion 1:2:4 and with two coats of kiricide oiling to the timber faces in contact with C.C and masonry as directed and specified.
(a) With sal wood
Providing, fitting and fixing factory made Santro Flush door shutters having core & cross bands fabricated from seasoned 1st class timber, 25mm core battens, 2.5mm to 3.5mm uniformly thick cross bands, styles & rails made from hardwood timber of width not less than 50mm, fixed to the door frames (chowkath) with necessary hinges, screws, bolts etc. as specified and directed at all levels (Door fixtures and fittings to be measured and paid seperately.)
(a) 30mm thick
DOOR AND WINDOW FITTINGS
ALUMINIUM FITTINGS
Supplying,fitting,fixing anodised aluminium fittings of approved make,reasonably smooth,free from sharp edges and corners,flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc.complete.(anodised to bright natural matt &satin finished)
(a)Sliding door bolts
(ii)250mm x16mm
(b)Tower bolts
(iii)200mm x12mm
(c) Door handle
(iii)150mm
t) Door stopper with rubber stopper
uPVC Windows
Supplying and installing uPVC- Fixed Windows made out of Lead free,UV resistant green profile having "GREENLINE" mark of BIS standard uPVC multichambered sections of wall thickness 2.4mm with corners fusion welded, fully reinforced with galvanized steel 1.5/2mm including glazing bead , grooving bead, drain cap, fisher screws, packing pieces, necessary stainless steel screws etc. complete as directed. The windows must be installed complete with all kinds of ironmongery including EPDM gaskets, bridging wedges and glass packers and with suitable water draining system. Application of Silicon sealant from inside / outside of dowcorning / GE or equivalent complete as directed. With 5mm clear glass
(a) Fixed window using uPVC sections of minimum sizes 58mm x 52mm x 2.4mm thick wall for frame and 58mm x 68mm x 2.4mm thick wall for glass sash. (WINSTA KOMMERLING/ FENESTA/ ENCRAFT)
with toughten glass
ANTI-TERMITE TREATMENT
PRE-CONSTRUCTION ANTI-TERMITE TREATMENT
Pre- construction anti-termite treatment at the bottom of foundation pits and walls on either side up to a height of 300 mm from bottom of the excavation made for column plinth beam, wall, trenches etc. by applying the emulsion @ 5(five) litres per square meter of the surface area before starting construction work(supplying of neccessary tools and accessories by the contractor) as per the direction of the Department complete.
a) with aqueous emulsion having concentration 1:19 with chloropirophose solution(tricel or equivalent) and water, i.e. 1% solution.
Pre construction anti - termite treatment by applying in the entire levelled area after plinth filling and before laying floor by applying the emulsion @ 5 (five) litres per square meter of the surface to be spread with light rodding so as to ensure proper absorption by the filled up earth (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete.
a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
Pre construction anti - termite treatment by applying the soil along the external perimeter of the building (after construction completed) to a distance close to the plinth wall as specified and as directed by the deptt. up to a depth of 300mm making rod holes along the line @ 150mm apart to a depth of 300mm and applying emulsion @ 4.5 litres per running meter ensure moistening of the soil with emulsion (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete.
a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
PLINTH PROTECTION
Providing plinth protection with bricks flat laid in cement mortar 1: 4 and finished with 15mm thick cement plaster in prop. 1:2 with a floating coat of neat cement finish.
Providing drain with brick work in cement mortar in proportion 1:5 with half brick thick side walls and 100mm thick C.C (1:3:6) base over one brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shuttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified.
ii). 300mm wide and average 250mm deep with bed slope 1 in 150 with initial depth of 100mm.
DEMOLISHED AND DISMANTLING
DEVELOPMENT OF MER GHAR COMPOUND WALL
SURFACE PREPARATION
(a) Removing white or colour wash by steel wire brushing and/ or scraping, sand papering and preparing the wall surface smooth including necessary repairs to scratches complete.
CEMENT PLASTERING
15mm thick Cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed.
(A) on raugh side
(b) In cement mortar 1:4
PAINTING
CEMENT PAINT & PRIMER
a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
WEATHER COAT EXTERIOR PAINT.
Finishing wall with water proofing weather coat anti-fungal premium acrylic smooth exterior finish of snowcem XT brand of Snowcem India Ltd. Of required shade on old/ new wall surfaces to give an even shade after cleaning and clearing the surface etc. including scaffolding complete as directed at all levels( 2 coats.).
FANCING
Supplying, fitting and fixing chain link fencing of 10 S.W.G, G.I. Wire 50mm x50mm mesh fitted to M.S angle iron post at 2000mm apart of specification detailed below including supplying, fitting and fixing hooks, eye bolts with nuts, staples and bolts including three horizontal lines of G.I wire 10 S.W.G at top,middle and bottom and with one vertical line to each fencing post for keeping the fencing tight and erect complete, including one coat of primer painting to M.S angle iron post in P.C.C base etc. with following.
a) Corner and end posts with M.S angle of size 50mmx50mmx 5mm and length not less than 1800mm only duly slotted and bottom torqued with two numbers as stay posts..
b). Intermediate post with M.S angle of size 40mmx40mmx5mm and length not less than 1800mm only duly slotted and bottom torqued and splayed.
c).Stay post with M.S angle of size 35 mmx35mmx5mm and length not less than 1800mm duly slotted and bottom torqued and splayed. All M.S angle iron posts are to be fitted to P.C.C base embedded not less than 600mm (P.C.C. work shall be measured and paid separately).
MERGHAR PATH WAY
EARTH WORK
Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified.
(a) In ordinary soil
FILLING
Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete.
(c).Stone soling of thickness 150mm.
CEMENT CONCRETE WORKS
PLAIN CEMENT CONCRETE WORKS
Plain cement concrete floor base in prop1:3:6 laid in alternate bays as specified with coarse agg. of size 13mm to 32mm including dewatering if necessary, and curing etc. complete.
b) 50mm thick
PAVER'S TILE
Proividing polished Multiwyn/DEVI/ VITA tiles of approved quality, size shape of specified thickness on pavers over a base course including cutting where necessary finished with flush pointing with Fix-A-Tile(Choksey/Sika/Pedelite/Rouf) white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed.
(B) DEVI Tiles (Pavers)
ii) Of size 300x300 mm of 30 thick
MERGHAR Electrical works
A. Wiring
Wiring for light/ fan/ call bell point with 2x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco or Equivalent Make as approved by the Deptt.) in recessed conduit wiring system with 2 mm thick 20mm dia rigid low halogen SFT PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) complete
SP upto 3.00 metre length.
MP upto 6.00 metre length.
LP upto 10.00 metre length.
Wiring to 5 a pin 6 Amps plug point with 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable HFFR/ZHFR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco or Equivalent Make as approved by the Deptt.) in recessed 2 mm thick rigid low halogen SFT PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system including earth continuity with 1.5 sq. mm. cable to third pin of the plug socket etc. as required complete.
SP upto 3.00 metre length.
MP upto 6.00 metre length.
LP upto 10.00 metre length.
Wiring for circuit wiring with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system.
With 3 x 1.5 sq. mm. cable in 20 mm dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system.
With 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm. in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
With 2 x 4 sq. mm. + earth continuity with 1x2.5 sq. mm. cable in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel or Equivalent Make as approved by the Deptt.) in surface/ recessed PVC 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system.
With 4 x 10 sq. mm. + earth continuity with 2x6 sq. mm. cable in 40 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
B. SWITCH/SOCKET/PLATE ETC.
Supplying including installation of socket outlet 10/16 Amps 3/5 pin combine shuttered complete , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying including installation of socket outlet 6/10/13 Amps INTERNATIONAL SOCKET , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying with fitting fixing of 16 amp one way modular clip in switch, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying with fitting fixing of 6/10 amp one way modular clip in switch, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) in surface/ recessed system complete as per direction of department.
3 module
6 module
12 module
Supplying including fitting fixing of following MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) front plate of suitable colour as per direction of department.
3 module
6 module
12 module
Supplying with fitting fixing of blank plate single in modular switch system , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
C. FITTING & FIXTURES.
Supplying and fixing of polished Brass Bracket of 18 S.W.G, 25 cm long cast back plate and brass lamp holder complete including connection as approved by the Deptt.)as required Without Lamp
Supplying,installation,testing and Commission of the following indoor Recessed Mounted LED Luminaires complete with all accessories such as driver etc. In the flase ceiling type Armstronng /Gypsum or similar ceiling mouting with necessary support and connection with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the department
Philips lighting luminaire 15 W GreenLED Model BBS170 1xDLED -5000 PSU WH/ BBS170 1xDLED -4000 PSU WH or GreenLED Square ModelBBS175 1xDLED -5000 PSU WH/ BBS175 1xDLED -4000 PSU WH or equivalent as approved by the Deptt.
Philips 24 W, Astra Surface & wall mounted LED batten Model BN150W LED20S-6500 PSE OD GR or equivalent as approved by the Deptt.
Supplying,installation,testing and Commission of the following LED lamp as directed by the department
Philips LED bulbs non-dimmable 7 W or equivalent as approved by the Deptt.
D. EARTHING
Installation of earth station with 40mm dia and 4.5 mtr. long GI pipe with necessary GI reducing socket 40mmx20mm size locking arrangement with hinged cover plate, funnel, GI nuts, thorough bolts etc.for putting pipe and refitting with necessary enclosure on the top etc. as required complete.
Extra for using salt 5Kg and charcoal 64 Kg. for pipe earth electrode as required.
Supplying and laying with 6 SWG GI earth wire at 0.50 mtr. below ground level or conductor earth electrode including soldering, excavation work and refitting etc.as required complete.
E.CEILING/EXHAUST FAN
Supplying including fitting fixing of following star rated A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection cable, as approved by the Deptt.s etc. as required complete and as directed by the Department [Without regulator]. (ORIENT PSPO make / Usha make/ CROMPTON make/ Havells/ ATC/ V GAURD make)
Energy efficient 5-star 1200 mm sweep. ORIENT PSPO / Usha / CROMPTON / Havells/ ATC or equivalent make
Supplying including fitting fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department.
Power Flow 225 mm sweep (ORIENT make)
G. MCB/MCBDB/RCCB ETC.
Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 double door surface mounting TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt.
ABB, Schneider MG, legrand, Hager make)
4way TPN (4+12) double door
Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.
C Series (Schneider MG, legrand, Hager make)
Supplying with fitting and fixing 30/100/300mA sensitivity 240/415V 50Hz 4P RCCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.
100/300mA sensitivity 4P RCCB (ABB, Schneider MG, legrand, Hager make)
Supplying including installation of the Octagonal poles shall be designed to withstand the maximum wind speed of 169 km/hr. The top loading i.e. area and weight of fixtures are to be considered to calculate maximum deflection of the poles and the same shall meet the requirement of BS:5649 Part VI 1982. The pole shaft shall have octagonal cross section and shall be continuously tapered with single longitudinal welding. There shall not be any circumferential welding of the pole shaft. The welding of the pole shaft shall be done by Submerged Welding process. All octagonal pole shafts shall be provided with the rigid flange plate of suitable thickness with provision for fixing 4 foundation bolts. The base plate shall be fillet welded to the pole shaft at two locations i.e. from inside and outside. The welding shall be done as per process approved by Third Party Inspection agency. (BAJAJ/ PHILIPS/ VALMONT/ PARUTHI ENGR/Nezone make)
Pole Type BOP or equivalent-4030, Height 3
Door opening The Octagonal poles shall have door of approximate 500 mm length at the elevation of 500 mm from the base plate. The door shall be vandal resistance and shall be weather proof to ensure safety of inside connection as approved by the Depts.. The door shall be flush with the exterior surface and shall have suitable locking arrangement. The pole shall be adequately strengthened at the location of the door compensate for the loss in section. There shall also be suitable arrangement for the purpose of earthing, Smart pack Junction box with 6 MCB & Terminals for mounting inside base compartment of Pole., Top Dia. (A/ 70 Bottom Dia. (A/ 130 Sheet Thickness 3, Base Plate , Dimensions :- (L x B x 200 x 200 x 12, Foundation Bolt , Bolt Size:- (no. x dia.) 4 x 16 Dia Pitch Circle Dia. (PC 200, Bolt Length 450, Projected Bolt Length 80, Anchor plate thickness:- 4 mm , Pole Foundation:- The octagonal poles shall be bolted on a pre- cast foundation with a set of four foundation bolts for greater rigidity. Foundation:- The foundation shall be done with, ( Earth work 2.04 cubic Meters, RCC 1:1.5 : 3 proportion 0.65 cubic metres, Steel 22.43 Kg, Shuttering 4.32 square metres. = 22.43 Kg.
Supplying including installation, connection cable, as approved by the Deptt. with 2x2.5 sqmm copper FR CABLE, testing and commissioning of the following street light on existing pole/ Structure including lamp, driver, ballast as required complete as directed and specified by the deptt.
Philips lighting luminaire 20w GreenLine Smart Model BRP022 LED 21 CW MR S1 PSU GR or equivalent as approved by the Deptt.
External wall cladding
Providing cladding with Green Building compliant Modified Clay Material (MCM) of Tunch/Phomi or equivalent brand of specified size and texture with base thickness of 2.5mm on internal/external walls/floors including surface preparation, cleaning & cutting, applying 1-2mm thickness of recommended specific adhesive on the MCM panel and pasting the MCM product on walls/floors finished with grouting and flush pointing (with recommended grouting material with coloured pigment to match panels as approved and directed by the Department).
Brick Design of "Burnt Umber" Shade of size 225x60mm
Extra (In case of grooves) for putting spacers in between the grouts to maintain uniform grooves and making good with grout and finish as described in Item 1.1
Water treatment plan
Automatic Chlorine Doser
Dual Media Filter
Iron Removal Filter
100 LPH Ultra Violet Filter
Taurus 50 LPH RO
Kent HEPA Aura Air Purifier
Toughened glazing of uPVC Window
Wide 600 mm, hieght 1200mm
Modular Toilet
Cubical :- Model type -ZMS SS Series, Thickness of campact laminate : 12mm colour of HPL, Board, Standard, size of cubicle : 1200mm x (W) x 1550 (D) x 2003mm (H), Door size : 1750mm (H) x 610mm (W), Overall height of cubical : 2003mm (including bottom gap of 150mm, Accessories, standard - MArino Make Aluminium stainless steel - 304 grade accessories, (a) Aluminium 'U' Channel, (b) Aluminium 'F' channel, (c) Aluminium door stopper channel, (d) Aluminium top rail, (e) SS Coat hook, (f) SS lock set C/W occupancy indicator, (g) SS Hinges with cover, (h) SS adjacible foot 316 grade, (i) Rubber door stopper lining, (j) SS screws 304 G & PVC wall plugs.
Abhijit Patowary
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .