Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.4 LAccepted-AOC LIG 10 VIVEK NAGAR NAVIBAGH BHOPAL MADHYA PRADESH 462038 | BHOPAL | MADHYA PRADESH | 462038 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹15.4 L+₹1.4 L (10.3%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹15.5 L+₹1.5 L (10.5%)Rejected-Finance 53 SHANTI S SANIK COLONY BAIRAGARH BHOPAL MP 462 030 | BHOPAL | BHOPAL | MADHYA PRADESH | 462030 | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹15.9 L+₹1.9 L (13.6%)Rejected-Finance 43 VIMAL ENCLAVE CHAMRAULI MODE SHAMSHABAD ROAD AGRA UP 282001 | AGRA | AGRA | UTTAR PRADESH | 282001 | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹16.1 L+₹2.1 L (15.3%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
21 Oct 2024, 6:00 pmClosed
GE BHOPAL
GE BHOPAL BAIRAGARH BHOPAL
REPAIR MAINT OF INTERNAL ELECTRIFICATION MD ACCN AND MISC WORK GE BHOPAL
2024_MES_676538_1
8305/E8
Open Tender
Electrical and Maintenance Works
Item Rate
183 days
BHOPAL
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE BHOPAL
₹50,000
Yes
6 Jan 2025
25 Sept 2024
23 Oct 2024
25 Sept 2024
21 Oct 2024
9 Oct 2024
Amount
Note :(i) Please refer Sch A/ BOQ Notes before quoting the tender for all phases/ items mentioned below. (ii) Amount of Schedule of credit shall be deducted offline
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete with fittings such as switches, ceiling roses, pendants, regulators, sockets etc. and making good disturbed surface of walls, floors, etc. complete all as specified and directed.
M&L for point wiring for one light / fan / bell point with 1.50 sqmm (nominal area) FRLS PVC insulated, unsheathed, multi-stranded copper conductor cable, 1100 volts grade, controlled by one-way switch, drawn in and including non metallic rigid PVC casing capping heavy duty, ISI marked, not less than 25mm base size with all fitting and fixing accessories including one run of 1.5 sqmm copper conductor as earth continuity wire connected to common earth dolly by suitable lugs, sunken sheet steel terminal box made out of 1.20 mm thick GI/MS sheet for mounting of fittings like switches, sockets, fan regulators, etc. complete all as specified and directed.
All as per tem No 2.00 here-in-before but for one light point controlled by two way switches.
All as per item No 2.00 here-in-before but for one 3 pin 5 Amp socket outlet on independent board.
All as per item No 2.00 here-in-before but for one 3 pin 5 Amps socket outlet point controlled by one switch on same board with other switches.
All as per item No 2.00 here-in-before but for wiring with 2.5 Sq mm copper cable for 5/15 Amp switch socket combination/ socket out let on independent board and provision of 2.5 Sqmm, FRLS PVC insulated unsheathed multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete.
All as per item No 2.00 here-in-before but for wiring with 4.00 Sqmm copper cable for 15 Amp switch socket combination/ socket outlet on independent board and provision of 4.00 Sqmm, FRLS PVC insulatedunsheathed multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete.
M&L for point wiring for one light / fan / bell point with 1.50 sqmm (nominal area) FRLS PVC insulated, unsheathed, multi-stranded copper conductor cable, 1100 volts grade, controlled by one-way switch, drawn in and including non-metallic rigid PVC conduit, concealed (ISI marked) medium grade not less than 20mm diameter with all conduit accessories in concealed wiring system by cutting of walls (brick or stone) and making good disturbed surface of wall in CM 1:3 (except on ceiling for fan point only, surface casing capping will be used in lieu of concealed PVC conduit) including one run of 1.5 sqmm copper conductor as earth continuity wire connected to common earth dolly, sunk sheet steel terminal box made out of 1.20 mm thick GI/MS sheet for mounting of fittings like switches, sockets, fan regulators etc. complete all as specified and directed.
All as per item No 8.00 here-in-before but for one light point controlled by two way switches
All as per item No. 8.00 here-in-before but for 3 pin 5 Amp socket outlet on independent board.
All as per item No 8.00 here-in-before but for one 3 pin socket outlet 5 Amps on same board
All as per item No 8.00 here-in-before but for wiring with 2.5 Sq mm copper cable for 5/15 Amp switch socket combination/ socket out let on independent board and provision of 2.5 Sqmm, FRLS PVC insulated unsheathed multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete.
All as per item No 8.00 here-in-before but for wiring with 4 Sq mm copper cable for 15 Amp switch socket combination/ socket out let on independent board and provision of 4 Sqmm, FRLS insulated multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete.
M&L for point wiring for one light / fan / bell point with 1.50 sqmm (nominal area) FRLS PVC insulated, unsheathed, multi-stranded copper conductor cable, 1100 volts grade, controlled by one way switch, drawn in existing concealed conduit including one run of 1.5 sqmm copper conductor as earth continuity wire connected to common earth dolly by suitable lugs complete all as specified and directed.
All as per item No. 14.00 here-in before but for 3 pin 5 Amp socket outlet on independent board.
All as per item No 14.00 here-in-before but for one 3 pin socket outlet 5 Amps on same board.
All as per item No. 14.00 here-in-before but for wiring with 2.5 Sq mm copper cable for 5/15 amp switch socket combination/ socket out let on independent board and provision of 1.5 Sqmm, FRLS PVC insulated unsheathed multi-stranded single core earth wire for earth continuity, connected to common earth dolly complete.
S&F of switch piano, flush type, single pole, one way, 6 Amps, 240 volt, 50Hz, AC, ISI marked complete all as specified and directed.
S&F of switch piano, flush type, single pole, two way, 6 Amps, 240 volt, 50Hz, AC, ISI marked complete all as specified and directed.
S&F of bell push, flush type, 6 Amp, piano type, 240 volt, 50Hz, AC, ISI marked complete all as specified and directed.
S&F of switch piano, one way, single pole, 15 Amp, 240 volt, 50Hz, flush type, ISI marked complete all as specified and directed.
S&F of socket outlet, 2 & 3 pin, 6 Amp flush type, 240 volt AC complete all as specified and directed.
S&F of socket outlet, 2 in 1, 5 pin, 5/ 15 Amp flush type, 240 volt AC complete all as specified and directed.
S&F of switch socket combination 2 in 1, 5 pin, 5/6 Amps flush type, 230 volt AC complete all as specified and directed.
S&F of switch socket combination, 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, flush type, 230 volt AC complete all as specified and directed.
S&F of ceiling rose surface bakelite, three terminals, 240V, 50Hz, ISI marked complete all as specified and directed.
S&F in repairs buzzer electric, single phase, 240 volt, AC complete all as specified and directed.
S&F in repairs bell, ding dong type, electric, single phase, 240 volt, AC complete all as specified and directed.
S&F in repairs LED tube light fitting, surface mounted lumanaires, 1 x 20 W, 240 V, decorative ultra slim round /square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient with bipin holders, LED lamps, connector block, etc. with all accessories internally pre-wired and connecting up with 3 core flexible copper conductor cable of suitable size complete all as specified and directed.
S&F in replacement LED tube rod 20/22 watt, 240V, PV > 0.90, colour temp 6500 K, system luminious efficancy > 100 LM/W complete all as specified and directed.
S&F of LED light fitting mirror type with high output diffuser 2 feet, 10 watt, 220 V, AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S&F of ceiling fan regulator electronic step type 240 V, AC 50 Hz single pole, 100 watts flush type complete all as specified and directed.
S&F of modular socket outlet 2-in-1, 5 pin, 6 Amps, 240 volts, controlled by one switch complete all as specified and directed.
S&F of modular socket outlet 2-in-1, 2/3 pin, 6/16 Amps, 240 volts, complete all as specified and directed.
S&F of modular switch socket combination 2-in-1, 5 pin, 6 Amps, 240 volts, controlled by one switch complete all as specified and directed.
S&F of modular switch socket combination, multipurpose 6 pin, 16 Amp, 3 module complete all as specified and directed.
S&F of modular fan regulator, 5 step, high speed complete all as specified and directed.
S&F of modular switch, one way, 6 Amp, one module, 240 volts complete all as specified and directed.
S&F of modular metal flush box of 6 module complete all as specified and directed.
S&F of modular metal flush box of 4 module complete all as specified and directed.
S&F of modular metal flush box of 3 module complete all as specified and directed.
S&F of modular white cover plate of 6 module complete all as specified and directed.
S&F of modular white cover plate of 4 module complete all as specified and directed.
S&F of modular white cover plate of 3 module complete all as specified and directed.
M&L for sub main wiring with approved colour coding as per IS (Red, Black and Green for single phase circuits) with two single core PVC insulated FRLS cable 1100 V unsheathed with stranded copper conductor of 4.0 sqmm nominal cross section area and drawing into rigid non metallic PVC conduit, ISI marked, medium grade, inclusive of all fittings such as tees, bends, junction boxes, elbows, saddles, pipe hooks, couples, lock outs, etc. 20mm external diameter and PVC insulated stranded copper conductor of 4.0 sqmm nominal cross section area as earth wire including taking down old unserviceable sub main wiring complete all as specified and directed. Note : Two runs of 4.0 sqmm cable, one run of 4.0 sqmm cable of earth continuity conductor and PVC conduit pipe shall be measured as one unit length.
M&L for sub main wiring with approved colour coding as per IS (Red, Black and Green for single phase circuits) with two single core PVC insulated FRLS cable 1100 V unsheathed with stranded copper conductor of 6.0 sqmm nominal cross section area and drawing into rigid non metallic PVC conduit, ISI marked, medium grade, inclusive of all fittings such as tees, bends, junction boxes, elbows, saddles, pipe hooks, couples, lock outs, etc. 20mm external diameter and PVC insulated stranded copper conductor of 6.0 sqmm nominal cross section area as earth wire including taking down old unserviceable sub main wiring complete all as specified and directed. Note : Two runs of 6.0 sqmm cable, one run of 6.0 sqmm cable of earth continuity conductor and PVC conduit pipe shall be measured as one unit length.
Taking down old unserviceable MCCB/MCB DB of any size and capacity including wooden boards complete all as specified and directed.
S&F of sheet metal enclosure for MCB, DB, TPN (triple pole and neutral), 4 ways, 415 Volts, 200 Amps rated busbar, double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43 including wooden rectangle board of first class hardwood of suitable size for mounting of DB box complete all as specified and directed.
S&F of factory made epoxy powder coated distribution board, TPN, 4 ways (VTPN MCCB DB) and space for MCCB as incomer, with metal door (IP-43 protection) fabricated from CRCA sheet and fixed semi flush to wall and suitable for universal mounting and including isolated neutral bar, insulated busbar assembly, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with knockouts complete all as specified and directed.
S&F of sheet metal enclosure for MCB, DB, SPN (single pole and neutral) 8 ways, 240 Volts, single door type concealed in wall, IP 43 with 200 Amps bus bar, dust and vermin proof suitable for incorporation MCBs and isolators etc complete all as specified and directed.
S&F of sheet metal enclosure for MCB, DB, SPN (single pole and neutral) 12 ways, 240 Volts, single door type concealed in wall, IP 43 with 200 Amps bus bar, dust and vermin proof suitable for incorporation MCBs and isolators etc complete all as specified and directed.
S&F of MCCB, 63 Amps, 3 Pole, breaking capacity 25 KA with complete electrical connections by appropriate size of copper lugs complete all as specified and directed.
S&F of MCCB 100 Amp, 3 Pole, breaking capacity 25 KA with complete electrical connections by appropriate size of copper lugs complete all as specified and directed.
S&F in repairs MCB, SP of capacity 6 to 32 amps, 240 volts, 10 KA breaking capacity, 'C' curve, including connection with suitable size copper lugs complete all as specified and directed.
S&F in repairs MCB, SP of capacity 40 to 63 amps, 240 volts, 10 KA breaking capacity, 'C' curve, including connection with suitable size copper lugs complete all as specified and directed.
S&F in repairs MCB, SPN of capacity 32 Amps, 240 volts, 'C' Curve with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed.
S&F in repairs MCB, SPN of capacity 40 to 63 Amps, 240 volts, 'C' Curve with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed.
S&F in repairs MCB, TPN of capacity 40 to 100 Amps, 415 volts with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed.
S&F in replacement 3 pin plug top, 15 Amps, 230 Volts AC complete all as specified and directed.
S&F in replacement sheet metal earth plug and socket, single pole and neutral with and including 1 No. single pole MCB 20 Amps 240 volts complete all as specified and directed.
S&F in replacement PVC insulated and PVC sheathed, flexible circular cable 3 core, 2.5 Sqmm strandered copper conductor AC, 240 V complete all as specified and directed.
S&F in replacement first class wooden rectangular board, closed recessed type of size 250 x 300 x 40mm for fixing and mounting single phase KWH meter with screws complete all as specified and directed.
S&F in replacement first class wooden rectangular board, closed recessed type of size 300 x 450 x 40mm for fixing and mounting single phase KWH meter with screws complete all as specified and directed.
S&F of non metallic rigid PVC casing and caping ISI marked of 20mm size complete all as specified and directed.
S&F of non metalic PVC conduit ISI marked of size 20mm dia complete all as specified and directed.
S&F of LED ultra slim decorative aluminium casted edge ceiling light, protuded type ceiling mounted 2' x 2' lED luminaire, 36 watt with all accessories internally pre-wired including connecting with PVC insulated multistranded copper flexible cable 1 sqmm three core complete all as specified and directed.
S&F of LED sleek round recess mounting LED ceiling light, 1' x 1' decorative type aluminium casted edge ceiling light, recess mounting LED, luminaire 15 watt with all accessories internally pre-wired including connecting with PVC insulated multistranded copper flexible cable 1 sqmm three core complete all as specified and directed.
S&F in repairs coral post top lantern fitting 25 Watt (for Gate light), energy saving, environment friendly, long life aesthetically designed with symmetrical light distribution with all accessories including connecting with PVC insulated multistranded copper flexible cable 1 sqmm three core complete all as specified and directed.
S&F in repairs LED tube light complete fitting, surface mounted luminanaires, 1x9 watt, 240V, decorative ultra slim round/square profile LED lighting fixture with extruded polycarbonate body, environment friendly, energy efficient ready to use pack with bipin holders, LED Lamps, connector block, etc complete with all accessories internally prewired including connecting with PVC insulated multistranded copper flexible cable 1 sqmm three core complete all as specified and directed.
S&F of building security light fitting 30 Watt made up of pressure die cast alluminium housing with high efficient LED as lighting source and pc over having top opening separate driver compartment with IP-66 protection and impact resistance of IK07 including suitable galvanized iron pipe 'light grade' brackets of 1 mtr length, bent to shape to obtain required shape including clamps, nuts/bolts/washers etc connecting with suitable copper wire of size 23/0.0076 complete all as specified and directed.
S&F in replacement flexible wire twin core copper conductor of size 23/0.0076 for ceiling fans, light fittings etc complete all as specified and directed.
M&L for earthing complete with galvanised steel plate earth electrode 600 x 600 x 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of size 32 x 6mm galvanised mild steel strip by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40cm X 40cm X 5cm reinforced with 8mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20mm dia GI pipe medium grade for watering, 20mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/strata and testing complete all as specified and directed.
Deduct Schedule of credit (calculation will be done off line) Rs. 59600.00
M S MEWALAL UPADHYAY (BID ID -3138773)
M/S Shanti Enterprises (BID ID -3138779)
S S TRADERS (BID ID -3138697)
Neelam Traders (BID ID -3146280)
Neha Enterprises (BID ID -3144999)
Raj Contruction (BID ID -3138864)
M/s VIKAS TRADERS (BID ID -3146069)
Rahul Verma (BID ID -3138933)
HARNAM SINGH ANIL SINGH (BID ID -3138706)
MODI CORPORATION (BID ID -3143499)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .