| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.3 LQualified | L1 | Qualified MII | |
| 2 | L2₹43.8 L+₹51,871 (1.20%)Qualified 0000 UNNAMED ROAD GAJIYA KANTIT VINDHYACHAL MIRZAPUR UTTAR PRADESH 231307 | MIRZAPUR | UTTAR PRADESH | 231307 | L2 | Qualified MSE, MII, Category: General | |
| 3 | L3₹45.1 L+₹1.8 L (4.23%)Qualified NEAR RAILWAY CROSSING ADAMPUR DOABA JALANDHAR JALANDHAR PUNJAB 144103 | JALANDHAR | PUNJAB | 144103 | L3 | Qualified MII |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
4 Mar 2025, 8:00 pmClosed
Taking down of light fittings of any type size and model complete all as specified
Taking down of brackets of any type size and model complete all as specified
M and L in repair steel tubular swaged poles complete with cast iron base plate finial taper plug
M and L in repair steel tubular swaged poles complete with cast iron base plate
finial taper plug
Re fixing of LED street light fittings of any wattage outdoor type complete all as specified and directed.
S and F in repair LED street light fitting 120 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing
Supply and fixing in repair LED flood light 80 watt 230 V AC outdoor type with thermal management in multiple optics and equipped
S and F in repair LED flood light 150 watt 230 V AC outdoor type with thermal management in multiple optics and equipped
S and F Cable Junction Box 155X210X92 mm in size
made out of thermoplastic having IP 66 protection for outdoor installation fixed with 4 way
Supply and passing through steel tubler pole service connection 1100 volts grade multicore FR round insulated copper conductor
S and F single arm bracket made of 40mm dia 1.0mtr long for security light with mounting MS clamp
S and F in repair Rigid non metallic PVC conduit of dia 20 mm exclusive of boxes junction terminal but inclusive of all
M and L for earthing complete with MS galvanized plate of size 60cmx60cmx6mm as earth electrode buried directly in ground
Taking down out unservicable or servicable UG cable of any cross section area and connection etc.
Excavating in Trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr in depth
Returning Filling in including Spreading
Levelling Watering and Well Ramming in Layers not exc.
Removing excavated Materials Soils not exc. 50.00 mtr and depositing where directed at a level not exc.
M and L Sand Cushioning dry in Trenches for protection of UG Cables below above and around the UG Cable
M and L for fly ash bricks locally available laid dry width wise across the line of cable in trenches for protection of UG cable
S and L for cable in trenches or passing through pipe
XLPE insulated 25 sqmm 4 core.
S and L for cable in trenches or passing through pipe
XLPE insulated
heavy duty
galvanised steel strip or wire armoured electric LT cable 10 sqmm 4 core.
Re laying fixing or passing through XLPE insulated armored electric power UG cable etc.
S and F 40 mm High density polyethylene pipe HDPE of pressure rating 6 kgf cm2 fixed complete to walls ceilings or in floors etc. complete all as specified and directed .
S and F Galvanised Iron Pipe 40mm Bore dia Light Grade for protection of UG Cable laid in Floors
Labour only for Horizontal Boring for Passing Protection Pipe up to 80mm Bore dia under Road Foot Path
not exc. 10.00 mtr
M and L for PCC 1.2.4 type B1 using 20 mm graded aggregate as in coping for pole including form work and finishing the surfaces
M and L for PCC 1.3.6 type C2 using 40 mm graded aggregate as in foundation for pole etc complete all as specified and as directed.
S and F HDPE DWC Double Walled Corrugated of Diameter 25 mm including disconnection and connection of cable.
M and L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn
Wrecking Crow Bar or Claw Bar as per IS 706 (Q3) Bid Details 2/25
7444601
GEM/2025/B/5880740
Two Packet Bid
Taking down of light fittings of any type size and model
90 days
Hooghly, West Bengal
Total value wise evaluation
BOQ
5 documents required · 5 mandatory
3 yrs
30%
Exempted
11 Feb 2025
11 Feb 2025
4 Mar 2025
Taking down of light fittings of any type size and model complete all as specified
Taking down of brackets of any type size and model complete all as specified
M and L in repair steel tubular swaged poles complete with cast iron base plate finial taper plug
M and L in repair steel tubular swaged poles complete with cast iron base plate
finial taper plug
Re fixing of LED street light fittings of any wattage outdoor type complete all as specified and directed.
S and F in repair LED street light fitting 120 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing
Supply and fixing in repair LED flood light 80 watt 230 V AC outdoor type with thermal management in multiple optics and equipped
S and F in repair LED flood light 150 watt 230 V AC outdoor type with thermal management in multiple optics and equipped
S and F Cable Junction Box 155X210X92 mm in size
made out of thermoplastic having IP 66 protection for outdoor installation fixed with 4 way
Supply and passing through steel tubler pole service connection 1100 volts grade multicore FR round insulated copper conductor
S and F single arm bracket made of 40mm dia 1.0mtr long for security light with mounting MS clamp
S and F in repair Rigid non metallic PVC conduit of dia 20 mm exclusive of boxes junction terminal but inclusive of all
M and L for earthing complete with MS galvanized plate of size 60cmx60cmx6mm as earth electrode buried directly in ground
Taking down out unservicable or servicable UG cable of any cross section area and connection etc.
Excavating in Trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr in depth
Returning Filling in including Spreading
Levelling Watering and Well Ramming in Layers not exc.
Removing excavated Materials Soils not exc. 50.00 mtr and depositing where directed at a level not exc.
M and L Sand Cushioning dry in Trenches for protection of UG Cables below above and around the UG Cable
M and L for fly ash bricks locally available laid dry width wise across the line of cable in trenches for protection of UG cable
S and L for cable in trenches or passing through pipe
XLPE insulated 25 sqmm 4 core.
S and L for cable in trenches or passing through pipe
galvanised steel strip or wire armoured electric LT cable 10 sqmm 4 core.
Re laying fixing or passing through XLPE insulated armored electric power UG cable etc.
S and F 40 mm High density polyethylene pipe HDPE of pressure rating 6 kgf cm2 fixed complete to walls ceilings or in floors etc. complete all as specified and directed .
S and F Galvanised Iron Pipe 40mm Bore dia Light Grade for protection of UG Cable laid in Floors
Labour only for Horizontal Boring for Passing Protection Pipe up to 80mm Bore dia under Road Foot Path
not exc. 10.00 mtr
M and L for PCC 1.2.4 type B1 using 20 mm graded aggregate as in coping for pole including form work and finishing the surfaces
M and L for PCC 1.3.6 type C2 using 40 mm graded aggregate as in foundation for pole etc complete all as specified and as directed.
S and F HDPE DWC Double Walled Corrugated of Diameter 25 mm including disconnection and connection of cable.
M and L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn
Wrecking Crow Bar or Claw Bar as per IS 706 (Q3) Bid Details 2/25
Taking down of light fittings of any type size and model complete all as specified and directed.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_7444601.pdf
GEM_BID
list-of-categories-where-trials-are-allowed_1712126171.pdf
OTHER
gtc.pdf
OTHER
demand_all_svc_2025-01-28-19-36-26_10c8ca93985f72479fb3b47ffc0bf4ad.pdf
BOQ
lgt_1_2025-01-28-19-36-26_0d4464c3b9e645bf892ce5e46d76d713.csv.pdf
BOQ
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .