Supply and Replacement of Damaged Dewatering Pipeline, Fire Fighting Pipeline, Cooling Water pipeline and Refilling of Fire extinguishers and Filtration of oil to Motor Transformers, Station Transformers and SFC Transformers for Operation and Maintenance works of -MGKLIS Lift-2 Pumping stations at Jonnalaboguda Reservoir near Khanapur (V), Koderu (m), Nagarkurnool Dist for the year 2025-26
687512
08/SE/IC-1/NGKL/2025-26
OPEN
Civil Works
NAGARKURNOOL
14 documents required · 10 mandatory · 4 optional
₹1,665
₹47,100
26 May 2026
25 Apr 2026
27 Apr 2026
Supply, Transportation, laying, testing & commissioning of 300 MM 'C'class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade at at Site complete as required Makes: Jindal Hissar/Tatą pipes complete for finished item of work or directed by the Engineer-in-charge
Supply, Transportation, laying, testing & commissioning of 150 MM Dia 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting withtwo or more coats of synthetic enamel paint of required shade complete as required Makes: Jindal Hissar/Tatá pipes at Site complete for finished item of work or directed by the Engineer-in-charge
Supply, Transportation, laying, testing & commissioning of 100 mm Dia 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like, elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required Makes: Jindal Hissar / Tata pipes at Site complete for finished item of work or directed by the Engineer-in-charge
Supply and Transportation of of INVERTER Model Cool type split AC unit with high wall mounted Single Split 100% copper indoor and outdoor condencing unit Hermetically sealed compressor suitable for operation on 230V, 50Hz, 1Phase AC supply capable of performing Heat cool dehumidifying air circulating and filtering with cooling and condensing units with 3.0 mts of copper piping, insulation kit and 4 mts of 4 core copper flexible chord (Voltage range 160-264 volts) and cordless remote control with with warranty of compressor for 5 years and comprehensive maintenance for 2 years. 2.0/1.8 TR 5 Star capable of delivering 21600 BTU/hr and above with operating on refrigerant R-32/R-410 Makes: Daikin / Toshibha / Carrier / Blue Star/ Hitachi or equivalent complete for finished item of work or directed by the Engineer-in-charge
Supply and Installation of copper tubing between indoor and outdoor unit for split Air-Conditioner including foaming etc., complete for finished item of work or directed by the Engineer-in-charge
Supply, Fabrication of 1set MS bracket suitable for fixing outdoor unit of split AC unit complete for finished item of work or directed by the Engineer-in-charge
Filteration of transformer oil as per ISS specifications filters to die electric strength Lit above 40 KV at Site complete for finished item of work or directed by the Engineer-in-charge
Refilling of Fire extinguisher of ABC type by dismantling from site to work shop for refilling includes removing of existing powder and cleaning the cylinder, delivery pipe, nozzle internally and refilling new powder complete with reinstalling properly at site with necessary certificate including transportation and labour charges etc., complete for finished item of work or directed by the Engineer-in-charge
Refilling of Fire extinguisher of CO2 type by dismantling from site to work shop for refilling includes removing of existing powder and cleaning the cylinder, delivery pipe, nozzle internally and refilling new powder complete with reinstalling properly at site with necessary certificate including transportation and labour charges etc., complete for finished item of work or directed by the Engineer-in-charge
(Rupees Forty Seven Lakhs One Thousand Nine Hundred and Sixty Four Only)
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
Lift-II Damaged Pipeline TD for Rs.56.09Lakhs.docx
TENDER_DOCUMENT • 0.66 MB
Schedule- A of Lift 2.xlsx
TENDER_DOCUMENT • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .