| 1 | L1₹17.0 LAccepted-AOC 114 SHASTRI NAGAR MEERUT | MEERUT | UTTAR PRADESH | 245206 | L1 | Accepted-AOC Accepted and admitted being L1 | |
| 2 | L2₹19.2 L+₹1.5 L (8.59%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹19.9 L+₹2.3 L (13.0%)Rejected-Finance D 55 HAKIKAT RAI RD ADARSH NAGAR DELHI 33 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹21.5 L+₹3.8 L (21.6%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹21.8 L+₹4.1 L (23.4%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
23 Sept 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (North)
GE (North) Meerut Cantt PIN 250001
MAINT AND REPAIRS TO INTERNAL ELECTRIC SUPPLY AND CONNECTED WORKS AT EBS BABUGARH UNDER AGE EM I OF GE NORTH MEERUT CANTT
2021_MES_470696_1
8286/E8
Open Tender
Civil Works
Item Rate
180 days
Meerut
Class E
Category b i
13 documents required · 13 mandatory
₹500
GE (North)
₹40,000
Yes
16 Nov 2021
26 Aug 2021
25 Sept 2021
26 Aug 2021
23 Sept 2021
9 Sept 2021
60 days
Amount
Taking down carefully copper/ aluminium point wiring (light, fan,socket or power) complete, including fitting & fixtures such as switches with board, ceiling roses, pendents, bell, bell push, lamp holders, regulators, sockets, light fittings etc., removing material from site and making good disturbed surfaces of walls, floors etc. including paint touch up to match with the existing surface complete all as specified and as directed.
M&L for point wiring complete with two runs of 1.5 sq mm single core PVC insulated FRLS cable 1100 volts grade with multi-stranded copper conductors, drawn thorough and including non metallic med. grade rigid PVC conduit with all conduit accessories (including concealing and finising to match with the sorroundings) and including provisoin of 1.5 sqmm PVC indulated copper cable FRLS as earth continiuty conductor, fabricated steel teminal box made out of 1.60 mm thick MS sheet concealed in walls and covered with 3 mm thick hylum sheet for fixing the switches /sockets/ regulators etc. complete all as specified and as directed. :- (a) One light point controlled by one way switch.
All as per Srl item No 02 here-in-before but One light point controlled by 2-way switch.
All as per Srl item No 02 here-in-before but One ceiling fan/ exhaust fan point controlled by one way switch.
All as per Srl item No 02 here-in-before but One 3 pin socket outlet 5 Amps on the same board with other switches.
All as per Srl item No 02 here-in-before but One 3 pin socket outlet 5 Amps on the Independent board.
All as per Srl item No 02 here-in-before but One bell/ buzzer point controlled by one push button on the same board with other switches
All as per Srl item No 02 here-in-before but with 2.5 Sq mm for 3 pin 15 Amps socket point controlled by one switch on independent board and 2.5 Sq mm copper conductor green in colour as earth continuity conductor complete all as specified and as directed.
All as per Srl item No 02 here-in-before but for supply and drawing 1.5 sqmm copper conductor cable with one 1.5 sqmm continuous earth wire into existing conduit after taking out the existing wiring including replacement of required size of terminal box with 3mm thick bakelite sheet cover fixed with brass screws all as specified and as directed for :- (a) One light point controlled by one way switch.
All as per Srl item No 09 here-in-before but One light point controlled by 2-way switch.
All as per Srl item No 09 here-in-before but One ceiling fan/ exhaust fan point controlled by one way switch.
All as per Srl item No 09 here-in-before but One 3 pin socket outlet 5 Amps on the same board with other switches.
All as per Srl item No 09 here-in-before but One 3 pin socket outlet 5 Amps on the Independent board.
All as per Srl item No 09 here-in-before but One bell/ buzzer point controlled by one push button on the same board with other switches or independent.
All as per Srl item No 09 here-in-before but with 2.5 Sq mm for 3 pin 15 Amps socket point controlled by one switch on independent board and 2.5 Sq mm copper conductor green in colour as earth continuity conductor complete all as specified and as directed.
All as per Srl item No 09 here-in-before but for 1.5 sqmm copper conductor cable with one 1.5 sqmm continuous earth wire into surface conduit wiring after taking out the existing conduit wiring including replacement of required size of terminal box with 3mm thick bakelite sheet cover fixed with brass screws all as specified and as directed for :- (a) One light point controlled by one way switch.
All as per Srl item No 16 here-in-before but One light point controlled by 2-way switch.
All as per Srl item No 16 here-in-before but One ceiling fan/ exhaust fan point controlled by one way switch.
All as per Srl item No 16 here-in-before but One 3 pin socket outlet 5 Amps on the same board with other switches.
All as per Srl item No 16 here-in-before but One 3 pin socket outlet 5 Amps on the Independent board.
All as per Srl item No 16 here-in-before but One bell/ buzzer point controlled by one push button on the same board with other switches
All as per Srl item No 16 here-in-before but with 2.5 Sq mm for 3 pin 15 Amps socket point controlled by one switch on independent board and 2.5 Sq mm copper conductor green in colour as earth continuity conductor complete all as specified and as directed.
S&F in repair Switch Piano, flush type single pole, one way 5 Amps complete all as specified and as directed.
S&F in repair Switch Piano flush type two way 5 Amps complete all as specified and as directed.
S&F in repair Switch Piano, flush type single pole, one way 15 Amps complete all as specified and as directed.
S&F in repair bell push 5 Amps flush type 5 Amps complete all as specified. and directed.
S&F in repair socket outlet 5 pin and 5/6 Amps flush type complete all as specified and as directed.
S&F in repair socket outlet flush type 2 in 1, 3 pin , 5 and 15 Amps complete all as specified and as directed
S&F in repair Stepped type electronic fan regulator flush type SP complete all as specifeid and as directed.
S&F in repair Stepped type electronic fan regulator flush type DP complete all as specifeid and as directed.
S&F in repair Ceiling rose PVC/ Polycorbonate insulated body with three terminals complete all as specified and as directed.
S&F in repair bell, Ding Dong type AC, 230 volts, SP complete all as specifeid and as directed.
S&F in repair Lamp holder PVC/ Polycarbonate type with back plate suitable for batten fittings including LED lamp 10W complete all as specified and as directed.
S&F in repairs LED tube light fitting surface mounting, CRCA batten decorative box type , 4 feet, 240V, 20 Watt, including T-8 poly carbonate diffuser type 20 watt rectrofit tube rod complete all as specified and as directed.
S&F in repairs integrated LED tube light fitting surface mounting, poly carbonate batten type, 4' , 240V, T5, 20 watt complete all as specified and as directed.
S&F in repairs integrated LED tube light fitting surface mounting, Poly carbonate batten,2', 240V, T5, 9/10 Watt complete all as specified and as directed.
S&F in repairs Retrofit polycarbonate diffuser type 20 watt retrofit LED tube rod 4 feet, 240V compete all as specified and directed
S&F in repair sub main wiring with two runs of 4.0 Sq mm and one run of 4.0 Sq mm for earth wire with multi standard copper conductors 1100 volts grade, drawn through and including PVC conduit and its accessories of suitable size and including concealing and finising to match with the sorroundings complete all as specified and as directed. NOTE:- two runs of 4.0 Sq mm + one run of 4.0 Sq mm and one run of PVC conduit and its accessories of suitable size shall be measured as one unit length complete all as specified and as directed.
S&F in repair sub main wiring with two runs of 6.0 Sq mm and one run of 6.0 Sq mm for earth wire with multi standard copper conductors 1100 volts grade, drawn through and including PVC conduit and its accessories of suitable size and including concealing and finising to match with the sorroundings complete all as specified and as directed. NOTE:- two runs of 6.0 Sq mm + one run of 6.0 Sq mm and one run of PVC conduit and its accessories of suitable size shall be measured as one unit length complete all as specified and as directed.
S&F in repair sub main wiring with four runs of 6.0 Sq mm and two run of 6.0 Sq mm for earth wire with multi standard copper conductors 1100 volts grade, drawn through and including PVC conduit and its accessories of suitable size and including concealing and finising to match with the sorroundings complete all as specified and as directed. NOTE:- four runs of 6.0 Sq mm + two runs of 6.0 Sq mm and one run of PVC conduit and its accessories of suitable size shall be measured as one unit length complete all as specified and as directed.
S&F in repair sub main wiring with four runs of 10.0 Sq mm and two run of 10.0 Sq mm for earth wire with multi standard copper conductors 1100 volts grade, drawn through and including PVC conduit and its accessories of suitable size and including concealing and finising to match with the sorroundings complete all as specified and as directed. NOTE:- four runs of 10.0 Sq mm + two runs of 10.0 Sq mm and one run of PVC conduit and its accessories of suitable size shall be measured as one unit length complete all as specified and as directed.
S&F in repair MCB Distribution board double door type (for incoming MCCB & out going MCBs) VTPN 4 way, sheet steel, powder painted, with bus bar neutral link & earth bar etc. and fixing only incoming MCCB and MCBs of various rating capacity including taking down existing unsv DB complete all as specified and as directed.
S&F in repair MCB Distribution board double door type TPN 8 way, sheet steel, powder painted, with bus bar neutral link & earth bar etc. and fixing MCBs of various rating capacity including taking down existing unsv DB complete all as specified and as directed.
S&F in repair MCB Distribution board double door type TPN 4 way, sheet steel, powder painted, with bus bar neutral link & earth bar etc. and fixing MCBs of various rating capacity including taking down existing unsv DB complete all as specified and as directed.
S&F in repair MCB Distribution board double door type SPN 12 way, sheet steel, powder painted, with bus bar neutral link & earth bar etc. and fixing MCBs of various rating including taking down existing unsv DB capacity complete all as specified and as directed.
S&F in repair MCB Distribution board double door type SPN 8 way, sheet steel, powder painted, with bus bar neutral link & earth bar etc. and fixing MCBs of various rating capacity including taking down existing unsv DB complete all as specified and as directed.
S&F in repair MCB Distribution board double door type SPN 4 way, sheet steel, powder painted, with bus bar neutral link & earth bar etc. and fixing MCBs of various rating capacity including taking down existing unsv DB complete all as specified and as directed.
S&F in repairs, 4 Pole MCCB 63 Amps, 50 Hz, 415 V with rupturing capacity 25 KA with thermal - Magnetic Release ISI Marked. complete all as specified and as directed.
S&F in repairs, 4 Pole MCCB100 Amps, 50 Hz, 415 V with rupturing capacity 25 KA with thermal - Magnetic Release ISI Marked. complete all as specified and as directed.
S&F in repair MCB TPN 63 Amps, 415 volts, 50 Hz suitable for fixing in MCB DB 'C' series complete all as specified and as directed.
S&F in repair MCB TPN 100 Amps, 415 volts, 50 Hz suitable for fixing in MCB DB 'C' series complete all as specified and as directed.
S&F in repair MCB SPN 40 Amps, 415 volts, 50 Hz suitable for fixing in MCB DB 'C' series complete all as specified and as directed.
S&F in repair MCB SPN 32 Amps, 415 volts, 50 Hz suitable for fixing in MCB DB 'C' series complete all as specified and as directed.
S&F in repair MCB SP 6-32 Amps, 415 volts, 50 Hz suitable for fixing in MCB DB 'C' series complete all as specified and as directed.
Supply & fix in repair Modular switch 6A one way complete all as specifeid and as directed.
Supply & Fix in repair Modular switch 16A one way complete all as specifeid and as directed.
Supply & fix in repair Modular Socket outlet 6A complete all as specifeid and as directed.
Supply & fix in repair Modular Socket outlet 6/16A complete all as specifeid and as directed.
Supply & fix in repair Modular switch bell push complete all as specifeid and as directed.
Supply & fix in repair Modular Fan Step regulator, 120 W-2 complete all as specifeid and as directed.
------------BLANK------------
------------BLANK------------
Supply & fix in repair/ replacement LED lamp 15 Watts 2 pin with B22 base, clear acrylic diffuser, power factor .90, 100 lumens per watt all as directed.with inbuilt accessories of capacity 5W complete all as specified and as directed.
All as per Srl item No 63 here-in-before but 12 Watts
All as per Srl item No 63 here-in-before but 9 Watts
All as per Srl item No 63 here-in-before but 5/6 Watts
Supply & fix in repair/ replacement LED 10 watt (Bulk head light fitting) cast aluminium oval shape body finished with stove enameled & heat resistant oval shape designed clear /diffuser glass cover with rubber gasket.with wire mash guard complete all as specified and as directed.
Supply only insulation tape 20mm x 25M ISI marked complete all as specified and as directed
Supply & fix in repair/ replacement LED pannel Recess mounted 2'x 2', 36 watts light fitting SIM type with inbuilt including connecting up with flexible copper cable of size 0.75 Sq mm 3 core from ceiling rose complete accessories and making all necessary connection complete all as specified and as directed
Supply, Install, Test & Commissioniong, Water Resistant / Splash Proof (IPX-4), Whirlflow technology, Electric Water Storage Heater (Geyser) 25 Ltrs capacity, AC, 230V, Vertical Type, 5 Star Rated, ISI Marked, Energy Efficient, having Feroglass coated / Anode Rod protected inner container / Tank, Incoloy Glass Coated Heating Element, High Density PUF insulated, Multi Function Safety Valve, Fire Retardant ISI Marked Heavy duty 3 core cable with shock Resistant Plug Top, Temperature Sensitive LED indicators, Adjustable Temperature Setting, 0.8MPa high working Pressure, Complete including suitable size Anchoring / Grouting Bolts with Nuts & Washers, necessary grouting in PCC incl earthing testing for the Geyser, Colour : White, Make : Venus / Havells / Racold incl T/D old u/s one and depositing to MES complete all as specified and as directed.
S&F in repairs, Energy efficient Ceiling fan, 1200mm sweep, 50 Watts, AC, 230V complete with set of 3 blades, down rod, hanging clamps, rubber reel insulator, G I bolts, nuts, washers etc. incl 1 Mtr 1.50 Sqmm FR insulalated PVC sheathed two core flexible cable incl T/D old u/s one and depositing to MES complete all as specified and as directed.
Supply & fix in repair/ replacement LED pannel Recess mounted 2'x 2', 24 watts light fitting SIM type with inbuilt including connecting up with flexible copper cable of size 0.75 Sq mm 3 core from ceiling rose complete accessories and making all necessary connection complete all as specified and as directed
Carrying out Electrical maint work of day to day Internal Electric or Fans or Geysers or Solar Water Heaters complaints such as repair / rectification / replacement of defective items like wiring, cables, switches, sockets,holders, ceiling rose, call bells, condensers,tube rods,fittings,fixtures,LED drivers, MCB's, MCCB's, DB's,Heating Elements,Thermostats, Hot water connections etc. by providing skilled Electrician at any location at EBS Babugarh under GE (North) Meerut AoR all as specified and directed by Engr-in-Charge.(Store required will be provided seperately) complete all as specified and as directed.
S&F in replacement of PVC water disributer 3 way with PVC pipe 15 mm with 15 mm dia flexible braided OD for Desert cooler of any size/capacity. complete all as specified and as directed.
S&F in replacement of Sumersible pump 18 watt, 230V, single phase for Desert cooler of any size/capacity.Make : Bajaj / CG complete all as specified and as directed.
S&F in replacement of wood wool pad for desert cooler of suitable size in wire net complete weight not less than 450 gms. ( set of three ) complete all as specified and as directed.
S&F in replacement fan motor copper wounded suitable for desert cooler 230 Volts, 50HZ, single phase, Heavy duty, AC supply four speed 180 watts of 450 mm sweep complete with fan blade and legs completed. Make : CG /Bajaj / Havells
S&F in reapirs, PVC fresh air fan, 300mm sweep with louvers, AC, 230V incl taking down old unserviceable one and depositing to MES store complete all as specified and directed.
Supply & fix in replacement copper cable 1100 volts grade with multi-stranded copper conductors of size 1.5 Sqmm complete all as specified and as directed
Supply & fix in replacement copper cable 1100 volts grade with multi-stranded copper conductors of size 2.5 Sqmm complete all as specified and as directed
Supply & fix in replacement copper cable 1100 volts grade with multi-stranded copper conductors of size 4.0 Sqmm complete all as specified and as directed
Supply & fix in replacement PVC insulated copper cable 1100 volts grade twin twisted flexible conductor 23/0.76 complete all as specified and as directed
Supply & fix in replacement PVC insulated copper cable 1100 volts grade twin twisted flexible conductor 40/0.60 complete all as specified and as directed
Supply & fix in replacement Temper proof digital energy meter Single Phase 230 volts of capacity 5-30A complete all as specifeid and as directed. NOTE: Taken down unsv Electric meter of any description will be deposited in E/M store. complete all as specified and as directed.
Supply & fix in replacement Temper proof digital energy meter three Phase 415 volts of capacity 10-40A complete all as specifeid and as directed. NOTE: taken down unsv Electric meter of any description will be deposited in E/M store. complete all as specified and as directed.
Taking down exisiting unserviceable service cable and supply & fixing 1100 volts gr, heavy duty cable, PVC insulated, stranded aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections, one twin core cable of size 4.0 Sqmm. complete all as specified and as directed.
Taking down exisiting unserviceable service cable and supply & fixing 1100 volts gr, heavy duty cable, PVC insulated, stranded aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections, one twin core cable of size 6.0 Sqmm complete all as specifeid and as directed.
Taking down exisiting unsv service cable and supply & fixing 1100 volts gr, heavy duty cable, PVC insulated, stranded aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections, one twin core cable of size 10.0 Sqmm complete all as specifeid and as directed.
M&L for earthing complete with galvanized steel earth plate electrode of size 600mm x 600mm x 6mm thick, buried directly in ground vertically to a depth not less than 2.25 Mtr below ground with top edge of the earth plate not less than 1.5 mtr below normal ground level, Earth plate shall be connected with double bolts, nuts, check nuts & washers, to & including 4.0 mm galvanized iron wire as earth lead, extended upto 7.5 m or upto test terminal point, drawn through 15mm dia med. gr. GI pipe for protection of galvanized iron wire in the ground, further connecting with suitable size of earthing lead to Distribution boards etc., including excavation, earth work, Charcoal & Salt all as specified, PCC chamber, RCC cover slab, watering pipe 20mm dia bore med. grade, wire net, funnel etc. & testing on completion all as specified in plate No.3 of SSR Pt-I, complete all as specified and as directed. NOTE: a) GI Pipe for protection of earthing strip and earth strip beyond 7.5m or test point shall be measured and paid seperately under relevant items. complete all as specified and as directed.
Taking down ceiling fan of any description, ceiling cable ends, dismantling blades, cleaning all dust, applying grease, filling cavaties with fillet, painting with synthetic enamel paint by spraying including reassembling blades and hanging ceiling fan including connecting up with flexible copper cable of size 0.75 Sq mm 3 core from ceiling rose fan connector complete all as specified and as directed.
All as per Srl item No 90 here-in-before but exhaust fans of any sweep complete all as specified and as directed.
Dismantling the unserviceable bearing and supply and fix sealed bearing suitable for the existing Ceiling fans / exhaust fans complete all as specified and as directed.
Dismantling the unserviceable Gun metal bush and supply & fix gun metal bush suitable for existing wall mounted/ pedestal/ exhasut fans complete all as specified and as directed.
Disconnect and remove unserviceable capacitor and Supply and fix capacitor of capacity 2.5 MFD suitable for ceiling fan / exhaust fan complete all as specified and as directed.
Disconnect and remove unserviceable capacitor and Supply and fix capacitor of capacity 3.15 MFD suitable for ceiling fan / exhaust fan complete all as specified and as directed.
Material & labour for removing the defective fan winding and rewinding with super enamelled copper wire of existing gauge, applying insulation varnish, pre heating and binding with empire tubes, crimple sheet etc. as required for rewinding complete all as spedified and as directed. (a) Ceiling fan of size upto 1200/1400 mm sweep.
All as per Srl item No 97 here-in-before but Exhaust fan of size 350 to 450mm Sweep.
All as per Srl item No 97 here-in-before but Exhaust fan of size upto 300 mm Sweep.
Taking down the electric Geyser of capacity 25 ltrs/ 50 ltrs carefully from its installed position by disconnecting inlet and outlet water pipes, electrical connections, dismantling the unit, painting with one coat of synthetic enamel paint and refixing in its original position and reconnecting the inlet/ outlet water pipes and testing on completion complete all as specified and as directed.
Supply and fixing of following items in repairs, suitable for single phase, 230 Volts, 50 Hz for existing type electric Geyser of capacity 25/50 ltrs including taking down old unserviceable spares items complete all as specified and as directed:- (a) Geyser heating element 1500 watts push/ thread type porcelain / Circular / triangular type as required at site.
All as per Srl item No 100 here-in-before but Geyser heating element 2000 watts push/ thread type porcelain / Circular / triangular type as required at site.
All as per Srl item No 100 here-in-before but Thermostat as per the existing type at site.
All as per Srl item No 100 here-in-before but Thermostate controller of existing type at site.
All as per Srl item No 100 here-in-before but Indication lamp red/ green.
All as per Srl item No 100 here-in-before but Aperture plate assembly complete for the geyser of capacity 25 ltr
All as per Srl item No 101 here-in-before but Aperture plate assembly complete for the geyser of capacity 50 ltr
Taking down the electric geyser of capacity 25 Ltrs / 50 ltrs carefully from its installed position by disconnecting inlet and outlet water pipes, dismantling the unit, taking out the inner leaking copper shell, brazing the copper shell, testing for leaks, re-assembling the geyser including provision of additional glasswool as required, refixing in position, testing for functionality and commissioning complete all as specified and as directed.
Taking down unserviceable PVC connection of any description and supply and fix new PVC connection 15mm dia 450mm long with brass nuts, and rubber washers on both sides suitable for cold/ hot water complete all as specified and as directed.
Taking down unserviceable PVC connection of any description and supply and fix new PVC connection 15mm dia 600mm long with brass nuts, and rubber washers on both sides suitable for cold/ hot water complete all as specified and as directed.
Servicing of Solar water of any capacity complete by cleaning soar panel with sutable cleaning agent complete all as specified and as directed.
Supply and fixing Solar water heater heating element of capcity 3 KW, single phase, 230 Volts, 50 Hz for existing type Solar water geyser including taking down unsv spares complete all as specified and as directed.
Disconnect and remove unserviceable starting relay and Supply and fix new starting relay suitable for existing model of following cooling appliances complete all as specified and as directed. complete all as specified and as directed. (a) Water cooler of capacity upto 150 Ltrs
All as per Srl item No 112 here-in-before but Refrigerator/ deep freezer of capacity upto 310 Ltrs
Disconnect and remove unserviceable over load protector and supply and fix new overload protector (OLP) suitable for existing model of following cooling appliances complete all as specified and as directed. (a) Water cooler of capacity upto 150 Ltrs
All as per Srl item No 114 here-in-before but Refrigerator/ deep freezer of capacity upto 310 Ltrs
Disconnect and remove unserviceable thermostat and supply and fix new thermostat suitable for existing model of following cooling appliances complete all as specified and as directed. (a) Water cooler of capacity upto 150 Ltrs
All as per Srl item No 116 here-in-before but Refrigerator/ deep freezer of capacity upto 310 Ltrs
Disconnect and remove unserviceable starting capacitor and supply and fix new starting capacitor suitable for existing model of following cooling appliances complete all as specified and as directed. (a) Water cooler of capacity upto 150 Ltrs
All as per Srl item No 118 here-in-before but Refrigerator/ deep freezer of capacity upto 310 Ltrs
Disconnect and remove unserviceable running capacitor and supply and fix new running capacitor suitable for existing model of following cooling appliances complete all as specified and as directed. (a) Water cooler of capacity upto 150 Ltrs
All as per Srl item No 120 here-in-before but Refrigerator/ deep freezer of capacity upto 310 Ltrs
Disconnect and remove unserviceable compressor and supply and fix new sealed rotary/ reciprocating compressor, including brazing the suction/discharge lines suitable for existing model of following cooling appliances, filling the gas and testing on complete all as specified and as directed. (a) Water cooler of capacity 40/80 Ltrs
All as per Srl item No 122 here-in-before but Water cooler of capacity 60/120 Ltrs
All as per Srl item No 122 here-in-before but Refrigerator/ deep freezer of capacity upto 165 Ltrs
All as per Srl item No 122 here-in-before but Refrigerator/ deep freezer of capacity 310/320 Ltrs
M&L for Checking of leakage of of the following cooling applainces by putting the nitrogen pressure, identifying the leaks / defects ,repairing the same by brazing/ welding of bottom leg supports and testing and vaccuumising the system and charging suitable refrigerant gas and oil in desired level complete all as specified and as directed . (a) Water cooler of capacity 40/80 Ltrs
All as per Srl item No 126 here-in-before but Water cooler of capacity 60/120 Ltrs
All as per Srl item No 126 here-in-before but Refrigerator/ deep freezer of capacity upto 165 Ltrs
All as per Srl item No 126 here-in-before but Refrigerator/ deep freezer of capacity 310/320 Ltrs
Taking down the corroded body of water cooler of any capacity, tinkering the corroded sheet metal parts, bottom base, angle iron frame, fan motor base plate, side covers, legs, door etc. with appropriate gauge MS sheet, angles by welding and brazing, renewal of nuts and bolts sheets metal screws, re-assembling, preparing the surface and painting with two coats of synthetic enamel paint over a coat of zinc chrome primer including renewal of door gasket where ever required complete all as specifeid and as directed.
Taking out unserviceable waste water tray of any description and supply and fix new steel waste water tray suitable for existing water coolers complete all as specified and as directed.
Taking out unserviceable ball valve assembly and supply and fix new PVC ball valves, high pressure with polythene float and fly nut complete screwed for iron pipe or brass ferrule of size 15 mm dia bore suitable for water coolers / desert coolers complete all as specified and as directed.
Taking out unserviceable push button tap and supply and fix new chromium plated push button tap of size 15 mm dia bore suitable for water cooler complete all as specified and as directed.
Taking out unserviceable stop valve of any description and supply and fix new stop valves, cast copper alloy screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions of size 15mm dia complete all as specified and as directed.
Taking out unserviceable PVC waste water pipe from Water cooler and supply and fix new PVC waste water pipe of suitable size complete all as specified and as directed.
Taking out unserviceable plug top of any description and supply and fix new plug top 3 pin 15 Amps single phase 230 volts complete all as specified and as directed.
Taking out unserviceable plug top of any description and supply and fix new plug top 3 pin 5 Amps single phase 230 volts complete all as specified and as directed.
Taking down unserviceable plug and socket of any description, supply and fix sheet metal enclosure with single pole and neutral with two pin and earth plug and socket along with a 20 to 30Amps rated SP MCB, 230 volt, 50 HZ as required at site, complete all as specified and as directed.
Disconnect and remove unserviceable copper cable of any description and supply and connect new PVC insulated and PVC round sheathed 3 core, 1.5 Sqmm Copper conductor cable, heavy duty, 1100 Volts grade complete all as specified and as directed.
Disconnect and remove unserviceable copper cable of any description and supply and connect new PVC insulated and PVC round sheathed 3 core, 2.5 Sqmm Copper conductor cable, heavy duty, 1100 Volts grade complete all as specified and as directed.
Disconnect and remove unserviceable electronic voltage stablizer of any description and supply and fix automatic electronic voltage stabilizer of capacity 1.0 KVA having features such as Intelligent time Delay system, Low and High Voltage Cut-off Protection, latest IC Technology to protect from power fluctuations, Thermal over load protection, wide input variation between 170V to 270V with output voltage stablized at 220 to 240V, with accuracy of +/- 2.5% and of following capacity suitable for Water cooler/ Refrigerator etc. complete all as specified and as directed.
M/S ABHI ASSOCIATES
GARG CONSTRUCTION CO
Narender Construction
AIRCOM
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .