Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹30.0 LAccepted-AOC C O HOUSE NO 16 RAGHUNATH PURA JAMMU J K | L-1 | Accepted-AOC Being the lowest bidder | |
| 2 | L-2₹34.0 L+₹3.2 L (10.4%)Rejected-AOC | L-2 | Rejected-AOC Not being the lowest bidder | |
| 3 | L-3₹34.5 L+₹3.7 L (12.0%)Rejected-AOC C O SECTOR 02 HOUSING COLONY CHANNI HIMMAT JAMMU J K PIN 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L-3 | Rejected-AOC Not being the lowest bidder | |
| 4 | L-4₹35.7 L+₹5.0 L (16.1%)Rejected-AOC 29 MODEL TOWN BEHIND GURUDWARA PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L-4 | Rejected-AOC Not being the lowest bidder | |
| 5 | L-5₹36.8 L+₹6.0 L (19.4%)Rejected-AOC B XXIII 56 A PREM NAGAR SAINGARGH PATHANKOT 145001 PUNJAB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L-5 | Rejected-AOC Not being the lowest bidder |
Tender Value
₹46.5 L
EMD Value
₹93,000
Closing Date
17 Aug 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
LT COL SANGRAM SINGH
GE Kaluchak Pin-900673 C/o 56 APO
SPECIAL REPAIRS REPLACEMENT OF EXISTING STREET SECURITY LIGHTS WITH LED LIGHTS REWIRING OF CERTAIN BUILDINGS PROVN OF ADDITIONAL SECURITY LIGHTS FOR SECURITY PURPOSE AND CEILING FAN AT KALUCHAK MIL STN UNDER GE KALUCHAK
2020_MES_363835_1
GE/KC/NIT-33/2020-21
Open Tender
Miscellaneous Works
Item Rate
180 days
Kaluchak
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE Kaluchak
₹93,000
Yes
28 Aug 2020
24 Jul 2020
19 Aug 2020
24 Jul 2020
17 Aug 2020
12 Aug 2020
24 Jul 2020 - 11 Aug 2020
60 days
Amount
Taking down carefully, copper / aluminium conductor unserviceable / perished point wiring (any type) for light/ fan/ light socket or power socket etc complete with fittings such as switches, sockets, ceiling roses, pendant holders, bracket holder, light fittings, regulators etc, including making good to disturbed surfaces of wall/floor etc, complete, all as specified & directed.
Taking down carefully unserviceable main switche fuse unit, distribution boards of any type/size from their position including making good to disturbed surfaces of wall etc, complete all as specified & directed.
Taking down carefully existing sub main wiring with aluminium conductor/copper conductor cable of any size with GI earth wire including wooden batten etc and making good disturbed surface of walls etc, complete all as specified & directed.
Taking down carefully electric meter of any description by disconnecting electrically and refixing the same in old or new location, complete all as specified & directed.
Point wiring with multi stranded FRLS PVC insulated unsheathed copper conductor cable single core of 1.5 Sqmm drawn into and including PVC concealed conduit 'ISI marked' of 20mm dia medium grade as required, fixed in concealed surface of wall/ceiling including cutting chases as required, terminated in pressed steel sunken box having wall thickness as directed suitable for housing of switches, socket, regulator etc, covered with 3mm thick bakelite 'hylam' laminated sheet cover complete with all accessories including single core FRLS PVC insulated unsheathed solid copper conductor cable of 1.5 sqmm for earth continuity conductor (green colour) and connected to earth dolly for one light/fan/bell point controlled by one way switch using proper colour coding, complete all as specified & directed.
All as per Srl item No. 5 above but for one 3/5 pin 5 Amps socket outlet on same board.
All as per Srl item No. 5 above but for one 3/5 pin 5 Amps socket outlet on independent board.
Point wiring with multi stranded FRLS PVC insulated unsheathed copper conductor cable single core of 4.0 Sqmm drawn into and including PVC casing caping (medium grade) of suitable size, fixed on wall/ceiling surface, terminated in pressed steel sunken box having wall thickness as directed suitable for housing of switches, socket, regulator etc, covered with 3mm thick bakelite 'hylam' laminated sheet cover complete with all accessories including single core FRLS PVC insulated unsheathed solid copper conductor cable of 2.5 sqmm for earth continuity conductor (green colour) and connected to earth dolly for one 3/5 pin socket outlet 15 Amps independent using proper colour coding, complete all as specified & directed.
Switch piano flush type 5 Amps 240 volt, single pole one way, complete all as specified & directed.
Switch socket combination, two in one, 5 pin type, 5 Amp, flush type universal, 240 volt, complete all as specified & directed.
Switch socket combination, two in one, 6 pin type, 5 & 15 Amp, 240 Volt, flush type universal, complete all as specified & directed.
Ceiling rose surface type, bakelite 65mmx50mm, 3 terminals, 240 Volt, complete all as specified & directed.
Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings, complete all as specified & directed.
Inverter LED lamp 6500K, 900lm in white colour of 9 watt, base cap B-22 with poly carbonate diffuser and aluminium heat sink, complete all as specified & directed.
Electronic fan regulator, 2 module, 100 watt, (5 stepped type), 240 Volt for 1200/1400 sweep AC ceiling fan, complete all as specified & directed.
Energy saving 10W LED bulk head luminaires, environmental friendly, ultra modern, energy saving, surface mounted, decorative oval bulk head edge-lit LED luminaire comprising of high brightness LEDs with all accessories prewired and making connections with copper flexible twisted twin cord of appropriate gauge and length, 230 volts, 50Hz, complete all as specified & directed. Make. Havells, Cat Part No.RUGBYNEONFT10WLED860SSYMTOPC/ C&S Cat Part No.LTB10LED/ Crompton Cat Part No.LBHE-10-CDL/ Halonix Cat Part No.HLBH-02-10-CW or equivalent model of make specified in List of Makes/ Manufacturers/ Producers here-in-after.
Tube light fitting integrated type suitable for LED 20W (4 feet) indoor, decorative aluminium extruded T5 LED batten complete with housing with all accessories pre-wired and making connection with three core copper flexible cable of size 23/0.0076 from ceiling rose to PVC connection to light fitting, complete all as specified & directed. Make: Philips Cat Part No: BN021CLED20SPSUCWGRS2/ C&S Cat Part No:LTTB4F20WLED/W / Halonix Cat Part No: HLB-03-20-CW-AL/ Havells Cat Part No: LUMILINEPLUSBS20WLED865SPCSS/ Crompton Modal Bright Linea CAT Part No: CCS-100-20-65-HL2-DP-NWH
Sheet metal enclosure, factory made for DBs, protection class IP-54, phosphatised powder coated, double door, triple pole & neutral, 415 volts fabricated from minimum 1.6mm thick CRCA sheet, fixed flush to wall, suitable for universal mounting including copper busbar 250 Amps, neutral bar, standard DIN rail, earth bar, earthing terminals and cable ties for cable management, top & bottom removable gland plates with knockouts,, 4 ways, suitable for four pole MCB/ Isolator/ RCCB/ RCBO as incomer and MCBs SP/TP as outgoing, complete all as specified & directed. Make: C&S Cat No. CSDBTPNVDD04S or equivalent model of make specified in List of Makes/ Manufacturers/ Producers here-in-after.
Sheet metal enclosure, factory made for DBs, protection class IP-43, phosphatised powder coated, double door, single pole & neutral, 230 volts fabricated from minimum 1.6mm thick CRCA sheet, fixed flush to wall, suitable for universal mounting including copper busbar 100 Amps, neutral bar, standard DIN rail, earth bar, earthing terminals and cable ties for cable management, top & bottom removable gland plates with knockouts, 12 ways, suitable for one SPN/DP MCB as incomer and MCBs SP as outgoing, complete all as specified & directed. Make: C&S Cat No. CSDBSPNDDA2+12 or equivalent model of make specified in List of Makes/ Manufacturers/ Producers here-in-after.
Sheet metal enclosure, factory made for DBs, protection class IP-43, phosphatised powder coated, double door, single pole & neutral, 230 volts fabricated from minimum 1.6mm thick CRCA sheet, fixed flush to wall, suitable for universal mounting including copper busbar 100 Amps, neutral bar, standard DIN rail, earth bar, earthing terminals and cable ties for cable management, top & bottom removable gland plates with knockouts, 08 ways, suitable for one SPN/DP MCB as incomer and MCBs SP as outgoing, complete all as specified & directed. Make: C&S Cat No. CSDBSPNDDA2+08 or equivalent model of make specified in List of Makes/ Manufacturers/ Producers here-in-after.
Sheet metal enclosure, factory made for DBs, protection class IP-43, phosphatised powder coated, double door, single pole & neutral, 230 volts fabricated from minimum 1.6mm thick CRCA sheet, fixed flush to wall, suitable for universal mounting including copper busbar 100 Amps, neutral bar, standard DIN rail, earth bar, earthing terminals and cable ties for cable management, top & bottom removable gland plates with knockouts, 04 ways, suitable for one SPN/DP MCB as incomer and MCBs SP as outgoing, complete all as specified & directed. Make: C&S Cat No. CSDBSPNDDA2+04 or equivalent model of make specified in List of Makes/ Manufacturers/ Producers here-in-after.
MCB, single pole, 6 to 32 Amp, 50 Hz AC supply, 10 KA repturing capacity, 240 Volt, 'C' series, complete all as specified & directed.
MCB, double pole, 32 Amp, 50 Hz AC supply, 10 KA repturing capacity, 240 Volt, 'C' series, complete all as specified & directed.
MCB, four pole, 32 Amp, 50 Hz AC supply, 10 KA repturing capacity, 415 Volt, 'C' series, complete all as specified & directed.
Sub main wiring using uniform coding of wiring with two runs of 6.0 Sqmm single core FRLS PVC insulated unsheathed cable upto and including 1100 volts grade with multistranded copper conductor drawn into and including PVC concealed conduit 'ISI marked' of 25mm dia medium grade as required, fixed in concealed surface of wall/ceiling including cutting chases as required with all fittings and fixing accessories & one run of 4.00 Sqmm FRLS PVC insulated solid copper conductor for earth continuity wire in green colour, complete all as specified & directed. Note:- Two runs of copper conductor 6.0 sqmm and one run of 4.00 Sqmm copper earth wire including PVC conduit of 25mm dia will be measured and paid as one unit only.
Intergral LED security light luminaire 60W LED, 230 volts made up of pressure die-cast aluminium housing with toughned glass and high power LEDs and secondry lenses with IP66 protection, efficacy 110 lumens per watt including 10 KV surge protection device, mounted on & including GI bracket made out of 40mm bore medium grade pipe of 1.70m length, bent to required shape, fixed on PCC/Steel pole with 02 Nos. clamps of flat iron (40 x 6mm), nuts, bolts and washers including painting with two coats of aluminium paint over a coat of red oxide zinc chrome primer, making connection with PVC copper conductor cable of 1.5 sqmm and taking down old unserviceable light fitting, complete all as specified & directed. Make. Crompton Greaves : Cat Part No. LSTP-60-CDL-M or equivalent model of make specified in List of Makes/ Manufacturers/ Producers here-in-after.
XLPE insulated, armoured heavy duty electric cable (heavy duty) with aluminium conductor, 1100 volts grade, cross-sectional area 16 Sqmm 4 core connected with suitable cable gland and aluminium lugs, laid in trenches or passing through pipes including testing after completion, complete all as specified and directed. (Earth work, brick protection and sand cushioning shall be measured and paid for separately)
XLPE insulated, armoured heavy duty electric cable (heavy duty) with aluminium conductor, 1100 volts grade, cross-sectional area 16 Sqmm 2 core connected with suitable cable gland and aluminium lugs, laid in trenches or passing through pipes including testing after completion, complete all as specified and directed. (Earth work, brick protection and sand cushioning shall be measured and paid for separately)
Earthing complete with galvanized mild steel earth plate electrode size 600mm x 600mm x 6mm thick buried directly in ground (preferably in vertical position) earth pit not less than 2.25 meter below normal ground level with top edge of the earth plate not less 3 meter (BGL), connected to galvanized iron earth lead wire 4mm dia by means of bolts, nuts, check nut and washer of galvanized iron including PCC pit in RCC 1:2:4 type B-1, precast RCC cover with suitable handle, excavation and earth work in any type of soil, 20mm bore “medium grade” galvanized iron water tubing fixed with cast iron funnel and wire mesh and 15mm bore 'light grade' galvanized iron protection pipe for earth lead wire upto 5m length, charcoal, common salt etc including connected to test point and testing on completion, complete all as shown in electrical plate No 3 of SSR Part-I 2009 & as directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth and getting out in any type of soil for foundation of pole, stay, taking up or laying of cable etc, complete all as specified & directed. Note : Due care shall be taken while deciding cable route for excavation. However any damage to Signal, BSNL, MES cable water/sewage pipe or any other service while excavation will be made good by the contractor and cost of the same for jointing material & labour is deemed to be included in the cost of excavation.
Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc. 25cm, complete all as specifed & directed.
Removing excavated material to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point, complete all as specified & directed.
Sand cushioning to under ground cable, laid in trenches 8cm thick below the cable and 15cm thick above the cable after laying and stretching the cable complete punned to 18cm, complete all as specified and directed. Note:- Punned thickness of sand will be measured and paid.
Galvanised iron tube 40mm bore light grade (ISI marked) for cable protection to poles/under floor/under roads/alongwith walls complete including MS clamps of flat iron 25x3mm duly painted, GI nuts, bolts and washers & sealing of pipe ends with approved sealing compound, complete all as specified & directed.
Brick well burnt locally available sub class 'B' laid over sand cushioning for mechanical cable protection in trenches with width of brick perpendicular to the length of cable, complete all as specified & directed.
PVC insulated twin core 2.50 sqmm (nominal area) aluminium conductor cable, 1100 volts grade, drawn in & including PVC conduit of suitable size with clamps (3 Nos), nuts, bolts etc from junction box to street light connection, complete all as specified & directed.
XLPE insulated, armoured heavy duty electric cable (heavy duty) with aluminium conductor, 1100 volts grade, cross-sectional area 25 Sqmm 3.5 core connected with suitable cable gland and aluminium lugs, laid in trenches or passing through pipes including testing after completion, complete all as specified and directed. (Earth work, brick protection and sand cushioning shall be measured and paid for separately)
Pole mounted distribution box powder coated for street light made of CRCA sheet of 3mm thick, dust and vermin proof, outdoor type of size 300mm x 260mm x 165mm with arrangement of incoming and outgoing feeder comprising of TPN aluminium bus bar of capacity 32 Amp 415 volts, single MCB SP, 230 V, 10 Amp 10 KA (in accordance with IS/IEC 60898-1), fixed on porcelain insulators, making holes on strips for connecting cables, fixed to street light pole with and including 2 Nos MS clamps made of FI 25x5mm with nut, bolt & washer duly painted with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer , complete all as specified & directed. Note : Wiring from DB to light fitting shall be measured & paid saperately under respective item of Sch 'A'.
Intergral LED security light luminaire 90W LED, 230 volts made up of pressure die-cast aluminium housing with toughned glass and high power LEDs and secondry lenses with IP66 protection, efficacy 110 lumens per watt including 10 KV surge protection device, mounted on & including GI bracket made out of 40mm bore medium grade pipe of 1.70m length, bent to required shape, fixed on PCC/Steel pole with 02 Nos. clamps of flat iron (40 x 6mm), nuts, bolts and washers including painting with two coats of aluminium paint over a coat of red oxide zinc chrome primer and making connection with PVC copper conductor cable of appropriate size, complete all as specified & directed. Make. Crompton Greaves : Cat Part No. LSTP-90-CDL-M or equivalent model of make specified in List of Makes/ Manufacturers/ Producers here-in-after.
Supply, hanging and testing of BEE 1 star rated energy efficient ceiling fan with double ball bearing, 1200mm (48 inch) sweep, having 3 blades, down rod, canopies, shackles, 230volt, single phase suitable for input voltage range140-285 volts, AC, 50Hz, higher air delivery minimum 230 cu metre/min or more, power consumption maximum 50 watt or lower, topspeed minimum 340 RPM or higher, speed control by 5 step electronic regulator, copper winding, complete as per IS:374-1979 or latest IE rule & site requirement, colour white, complete all as specified & directed.
M/S RAJ ENGINEERS
MAMTA ENTERPRISES
kailu construction co
SATISH AND CO
Vishesh Engineers
ASHISH CONSTRUCTION COMPANY
Jiwan Singh
M/S GHUMAN BUILDERS
SUMEET TRADING CORPORATION
M/S Sudagar Mal
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .