Loading…
Loading…
Tender Value
₹24.3 Cr
EMD Value
₹34.3 L
Closing Date
17 Aug 2026, 3:00 pmClosed
DGM BSBCCL MUZAFFARPUR
DEPUTY GENERAL MANAGER MUZAFFARPUR
BSBCCL, Hospital Road, Sastri Nagar, Patna 800023
ANIL KUMAR
CGM
Construction of Sports Infrastructure in campus of Munshi Singh College at Motihari Dist- East Champaran.
135996
12/BSBCCL/2026-27 GR02
Open Tender
CIVIL
Muzaffarpur
• Payment Receipt (EMD/Tender Fees/Tender Processing Fee)
• Total value of civil engineering construction work, in Rupees, Performed in last five years. (BALANCE SHEET, PROFIT & LOSS AND AUDIT REPORT DULY AUDITED BY CA.) Minimum annual financial turnover (in all classes of civil engineering construction works only) amount of construction work ,which must be at least equal to 50 % of estimated cost of works for which bid has been invited. The turnover will be indexed at the rate of 8% for a year
2021-22,
2022-23,
2023-24,
2024-25
2025-26
• Amount in Rupees related to Work Experience of Similar nature -i) Satisfactory completed at least one similar work of value not less than 50% of estimated Cost (Escalation As per appendix ITB sl no-19) ii) The completion Certificate shall be issued by employer not below the rank of executive engineer or project manager. In case of Private client the completion certificate and valuation of the project issued by employer should be certified by the retired executive engineer/Registered value of Nationalised Bank/Insurance Company/Income Tax Department.
• Qty /Amount As Indicated In Any One Year In Last Five Year (Quantity Executed Must Be Satisfied By Concern Engineer In charge. In case of Private client the quantity executed will be issued by employer should be certified by the retired executive engineer/Registered value of Nationalised Bank/Insurance Company/Income Tax Department. Fy-2021-22,2022-23,2023-24,2024-25,2025-26.
Earth work in excavation 3,175.46 cum
PCC/RCC 726.78 cum
Brick work 263.49 cum
GSB 807.92 cum
WMM 807.59 cum
BM+BC 407.83 cum
Flooring 123.25 sqm
Synthetic Athletics Track 3853.49 sqm
PHE 5.28 Rs (in lakh)
Electrical 154.08 Rs (in lakh)
• Attach Affidavit in Prescribed Format mention in SBD.
• Proposed Methodology of Construction.
• AS PER SEC 2-1.5 MAX. AGE 5 YEARS ATTACHED OWNED VOUCHER /CASH MEMO/INVOICE AND AFFIDAVIT IN CASE OF LEASED/HIRE ON AND AFTER DATE OF TENDER
Type of Equipment Nos. Maxm. Age
Steel Shuttering 10000 Sft 5
Concrete Batching & Mixing plant Minimum capacity 15m3/hr .1 5
Pump for concreting 1 5
Transit Mixture 1 5
Vibrator (Plate & Niddle) 5 5
Water Tanker 2 5
Paver Finisher 1 5
Motor Grader 1 5
Vibratory Rollar 1 5
• AS PER SEC 2-1.6 ATTACHED NECESSARY CERTIFICATE AND CURRENT AFFIDAVIT OF BOTH EMPLOYEE AND EMPLOYER ON AND AFTER DATE OF TENDER
1.Project Manager-B.E. Civil + 10 Years Exp. (5 years as Manager having MBA) or equivalent or retired E.E.-1 No.
2.Site Engineer / B.E. (Civil) + 03 Years Exp. (3 years in Building Construction) or Diploma in Civil + 7 year Exp. In Building construction or retired A.E.-2 no.
3.Plant Engineer-B.E. Mech./ Civil + 03 Years Exp. or Dip. Mech + 05 Years Exp. or Retired J.E. -1 No.
4.Quantity Surveyor-B.E. Civil + 03 Years Exp. or Dip. Civil + 05 Years Exp.-1 No.
5.Site Supervisor /Fresh Graduate in Civil or Diploma Civil + 02 Years Exp. or retired I.T.I Holder- 3 no.
• Litigation History if Any.
• Evidence of accesses to Financial Resources in Rupees-Evidence of access to or availability of credit facilities (10% of estimated cost), certified by bankers (for work under this bid).
• Undertaking -Able to invest a minimum of cost upto 25% of contract value of work. During implementation of contract.
• Registration No.-any Contractor Registered with Central Government/Any State Government/Any Public Sector Undertakings or an agency of National or International repute may tender, but Registration with Building Construction Department will be essential after issue of Letter of Acceptance.
• Experience Certificate of identified Sub Contractor (Electrical/PHE) will be valid. Experience Certificate should be issued by at least Executive Engineer and equivalent officer. It is Mandatory to Attached Mutual Affidavit & Registration Certificate of Sub Contractor.
• Legal Status/Place of Registration/Principal Place of Business/Power of Attorney.
• (a) Amount of Existing commitments and ongoing works in Rupees (Bidder must declare themselves their all existing commitment hiding fact be sufficient cause for rejection.)
• (b) Amount of Work for which Bid already submitted, in Rupees.
• ( c ) BIDDING CAPACITY ( BC=AxNx3-B) SHOULD BE MORE THAN BOQ.
• Character Certificate of identified Sub Contractor(Electrical/PHE) will be valid.Experience Certificate Should be issed by at least Exectutive Engg and Equivalent officer.It is Mandatory to Attached Mutual affidative and Registration & Experience Certificate of Sub Contractor.
• NOC for Debar.
• GST Registration Certificate, PAN & Aadhar Document.
• Submit Certificate: The bidder/manufacturer, acting as the primary contractor, shall have successfully supplied and installed at least one Class-I or Class-II certified (by World Athletics, formerly IAAF) synthetic athletic full PUR eight-lane 400m track in India during the last five years.
• Experience certificate for the construction of at least one indoor stadium using a prefabricated building, or for the construction of a prefabricated/M.S. steel truss building with a span of not less than 20 meters in India, completed within the last five years.
• Experience certificate for the construction of at least one natural or synthetic football ground, compliant with Khelo India Guidelines and/or FIFA Guidelines, including FIFA Quality Certification, completed within the last five years.
• If the primary bidder does not meet the specific conditions for Indoor Stadium and Football Stadium, including the required experience in the specialized scope of work for the construction of sports infrastructure as mentioned above, then the bidder is required to submit a binding subcontractor agreement with a specialized agency that possesses the necessary experience credentials to comply with the requirements of this scope. Such a subcontractor must comprehensively meet all the requirements/qualification conditions for the respective scope independently and not as part of a joint venture (JV). It is mandatory to submit the required completion certificates.
CIVIL
PERCENTAGE
L1
1
24 documents required · 24 mandatory
₹10,000
Processing Fee: 11800
₹34.3 L
CGM,BSBCCL
17 Aug 2026
14 Jul 2026
18 Aug 2026
14 Jul 2026
17 Aug 2026
14 Jul 2026
17 Jul 2026
Clearing grass and removal of the rubbish up to distance 50 m outside the periphery of the area
GRASS PLANNING: PROPER GRASS PLANNING (BERMUDA GRASS ) FORPITCH .WE PROVIDE THREE MONTH MAINTENANCE FOR GRASS DEVELOPMENT LIKE : PROPER CUTTING,WATERING,SPREADING OF FERTILIZERS ETC
Earth work in excavation over areas ( exceeding 30 cm in depth. 1.5 m in width as well es 10 sqm on plan) including disposal of excavated earth , lead upto 50 m and lift upto 1.5 m; disposed earth to be levelled and neatly dressed.
All kinds of soil
Ali kinds of soil
Excavating, supplying and filling of local earth (including royalty but excluding cairriage cost) by mechanical transport upto a lead of 3km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. If local earth is available at more than 3 km lead the actual lead must be approved by compitent authority. cairraiage of material will be paid seperately and calculated after deducting initial lead.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth: consolidating each deposited layer by ramming and watering lead
depth exceeding 1.5m apart
Supplying and Filling in plinth with local sand and under floors including, watering, ramming consolidating and dressing complete.
With Chlorpyriphos EC 20% with 1% concentration
Providing designation 100 A one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as per building specification and direction of E/l,
1:1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
1:2:4 (1 Cement: 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
Extra for Providing and mixing water proofing material in cement concrete work in the proportion recommended by the manufactures.
Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-incharge. (The panel shuttering work shall be paid for separately). (Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately)
All work upto plinth level : Concrete of M-25 grade with minimum cement content of 330 kg/cum
All work above Plinth level upto floor V Level : Concrete of M-25 grade with minimum cement content of 330 kg/cum
Walls columns, pillars, posts cind struts
Beams, planth beams, girders, bressumers, contilevers, Suspended floors lintels roofs and staircases including spiral staircases, shelves etc.
Proiding M-25 grade R.C.C. instead of M-20 grade R.C.C.
TMTC-500- 08 mm dia.
TMTC-500- 10 mm dia.
TMTC-500- 12 mm dia.
TMTC-500- 16 mm dia.
TMTC-500- 20 mm dia.
TMTC-500- 25 mm dia.
Foundations, footings, bases of columns etc. for mass concrete.
Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
Suspended floors, roots, landings, balcnies and access platform..
Lintels, beams, plinth bams, griders, bressumers and contilevers.
Columns,Pillars, Piers, Abutments, Posts and Struts
Edges of slabs and breaks in floors and walls :
Weather shade,Chajjas, corbels etc. including edges
Cement mortar 1 .:6 (1 cement: 6 coarse sand )
Cement mortar 1 .:6 (1 cement: 6 coarse sand ) : Extra tor Brick work in superstructure above plinth level upto floor V cum
Cement mortar 1:6 (1 cement: 6 coarse sand )
Cement mortar 1 : 4 (1 cement: 4 coarse sand )
Size of Tile 60x60 cm
Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (Thickness to be specified by the manufacture) of approved make in all colours, shades except burgundy , bottle green , black of any size as approved by Engineer-in-charge in skirting , risers of steps and dados over 12 mm thick bed of cement Motar 1:3(1 cement: 3 coarse sand ) and jointing with grey cement slurry @ 3.3 kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer) of ist quality conforming to IS : 15622 of approved make in colours such as white , Ivory , Grey , Fume Red , Brown , laid on 20 mm thick Cement motar 1:4 (1 cement: 4 coarse sand ) including pointing the joints with white cement and matching pigment etc., complete.
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete asper the architectural drawings with 18 mm thick stone slab over 20 mm (average)thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth.
Providing 250mm wide brick drain in cement mortar (1:6) with av. 150mm. Clear depth and 250mm apron including cost of E/W. involved with 75mm cement concrete
1:6(1 cement: 6 coarse sand)
15 mm cement plaster on rough side of single or half brick wall of mix : (1 : 4)
1:4(1 cement: 4 coarse sand)
15 mm cement plaster(1:3) with punning
Providing and applying white cement based putty of average thickness 2 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Two or more coats on new work
New work (Two or more coat applied @ 1.67 ltr/ 10 sqm over and including priming coat of exterior primer applied @2.20 kg/ 10 sqm)
Applying priming coat: With ready mixed zinc chromate yellow primer of approved brand and manufacture on steel galvanized iron/steel works
Painting with ready mixed paint of approved brand and manufacture in all shades to give an even shade: New steel work (two or more coats)
Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area upto 0.75 sqm.)
Three track three panels sliding window with fly proof SS wire mesh (Two nos. glazed & one no. wire mesh panels) made of (small series) frame 92 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area of window upto 1.75 sqm).
Fixed to steel windows by welding
Fixed to openings/ wooden frames with rawl plugs screws etc
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
Hot finished welded type tubes
With average thickness of 120 mm and minimum thickness at khurras point to be 65
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement:2 coarse sand:4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 mx1 mx400 micron, finished 12 mm cement plaster 1:3 (1 cement:3 coarse sand) and a coat of neat cement rounding the edges and making and finishing the outlet complete
With float glass panes of 5.50 mm thickness(weight not less than 12.50 kg/sqm)
Providing and fixing M.S.fan clamp type I or II of 16 mm dia.M.S. bar bent to shape with hooked ends in R.C.C slabs during laying including painting the exposed portion of loop,all as per standard design complete.
35 mm thick
Frame size 50 x 100 mm
Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
Single rubber stopper
Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes,channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, ( for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts,fasteners etc.).
Supply and fixing of Flashing /Ridge/ and gable flashing colour coated up to : Supply and fixing of Flashing /Ridge/ and gable flashing colour coated up to : 300mm - 500 mm girth.
Providing & Fixing GE plastic 600mm dia Turbo Vents of approved make and laying in position as per drawing or as directed by Engineer-in-charge
Providing & Fixing clear polycarbonate sheet 1000 mm wide & 1.5 mm thick of approved make and laying in position as per drawings matching profile with galvalium sheet or as directed by Engineer-in-charge
Supply and fixing of Colour coated gutters with gutter supports, sealnts
Supply and Fixing of down Color coated 0.5mm thk. Sheet take pipe, Pipe flashing band, M.S strip U-clamp with complete accessories in color coated sheet.
Providing and fixing soil, waste and vent pipes : Sand cast iron S&S pipe as per IS: 1729
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
150mm diameter S.W pipe
560 mm diameter C.I. over (heavy duty) the weight of the cover to be not less than 108 kg.
80 mm dia. Nominal bore
100 mm diameter Class I
Providing and laying factory made chamfered edge Cement Concrete paver blocks of required strength,thickness & size/shape, made by table vibratory method , to attain superior smooth finish using PU or equivalent moulds, laid in required Grey colour & pattern over 50mm thick compacted bed of coarse sand, compacting and proper embedding / laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with jamuna sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand in footpath, parks,lawns, drive ways or light traffic parking etc. all complete as per manufacturer’s specifications & direction of Engineer -in-Charge:
(a) 80 mm thick c.c. paver block of M-35 grade with approved colour design and pattern.
Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5
Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of Engineer-in-Charge.
DenseGradedBituminousMacadamGrading. II:--Providing and laying dense graded bituminousmacadamwith 100-120 TPHbatch type HMP producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous [email protected] byweightoftotalmix andfiller, transporting thehotmixtoworksite, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rollingwithsmoothwheeled,vibratory and tandem rollers to achieve the desired compactionasperMoRTHspecificationclauseNo. 507 complete in all respects.
Bituminous concrete Grading -II Providingand layingbituminousConcretewith higher capacity batchtypeHotMixPlant using crushed aggregates of specified grading [email protected]%ofmix and filler, transporting thehotmix toworksite, laying with a hydrostatic paver finisher with sensor control to the requiredgrade, level and alignment, rollingwithsmoothwheeled,vibratory and tandem rollers to achieve the desired compaction as per MORT&H specification clause No. 507 complete in all respect.
PrimeCoat:-Providingandapplyingprimercoat withbitumen emulsion onprepared surface of granularBase includingclearingof roadsurface andsprayingprimer at therateof 0.60kg/sqm using mechanical means
TackCoat :--Providing andapplying tack coat withbitumenemulsionusingemulsionpressure distributorat therateof0.20kgpersqmonthe prepared bituminous/granular surface cleaned with mechanical broom
Seal Coat :--Providing andapplying tack coat withbitumenemulsionusingemulsionpressure distributorat therateof0.20kgpersqmonthe prepared bituminous/granular surface cleaned with mechanical broom
Geo Textile to prevent ingress of soil
(i) Normal Stress Areas with a minimum thickness of 15mm ( within permissible limit ) of finished track surface.
(ii) High Stress Areas with a minimum thickness of 20mm (within permissible limit) of finished track surface.
(iii) High Stress Areas with a minimum thickness of 25mm (within permissible limit) of finished track surface.
(iv) IAAF approved line marking with class -2 field certification by IAAF / WA.
Water jump Socket with hurdle for steeple chase
Polevault boxes with cover
Take off board system for long jump and triple jump including wooden board
Hammer cum discuss throwing cage with all socket, pole, door and net
Discussnthrowing cage
short put ring
aluminium kerbing
conversion circle
Reducer for hammer cum discuss ring
Supply and Installation of Portable Aluminium Goal Post
Providing and laying of DWC - SN8 (IS:16098-II) pipes : 300 mm dia, Pipe in under ground system for provision in electrical line and sprinkler linesleeve purposes and drainage outlet complete in all respect as per direction of engineer in charge.
Testing for base surface level undulations by survey of the prepared bituminous surface within the acceptable tolerance level of Road work but beyond the acceptable tolerance of World Athletics Class-1 Certification. identification of high or low points under 4M and IM straightedge, AND rectification of the same by appropriate spot levelling method including but not limited to grinding, cutting, patch work, seal coat, etc. to achieve surface level gradients and evenness as per the requirements of World Athletics surface tolerance levels as per clause 3.1.3.2 of the World Athletics Track & Field Facilities Manual.
Excavation of top soil and add filling of good earth mixed with organic material incl. Compaction, slope upto 4 inch thickness.
Irrigation and maintenance of the grass for 6 month including watering, fertilizing and pesticide. (with exisitng equipments)
Anti termite treatment of lawn area through premise 30.50% I P. one liter premise diluted in 499 liters water and applying solution @ 1.00 litre solution per sqm lawn or bed area.(two application) i/c cost of chemical)and as per direction of officer-in-charge.and as per direction of officer-in-charge
Supplying and stacking 200mm thick layer of washed river sand as per FIFA specifications suitable for high performance Football outfield including mixing of organic inclusions such as coco peat, neem cake, etc. as per the design.
Providing and laying of 100mm dia perforated pvc sub soil drainage pipes 6 kg/cm2 pressure perforation at 50% area of pipe . Whole pipe covered with geotextile material of 140-180 gsm as per design and drawing. Incl. filling of 20-40mm size aggregate bed and wrapping of geo textile arround the pipe with all fitting for the pipe complete all as per direction of engineer-in-charge.
Mixing earth and sjudge or manure in porportion specified or directed.
Spreading of sludge,dumpmanureor/andgoodearth inrequired thickness (Cost of sludge,dumpmanureor/andgoodearth tobe paid separately).
New work (Two or more coats
Supply and installation of fully computerized, automatic and single key operation pop-up sprinkler system " for surfaces including all fittings and accessories, 110 mm dia HDPE Pipe, 50 HP motor (KIRLOSKER) automatic panel, hydrant etc., fulfilling irrigation norms
W.C. pan with ISI marked white solid plastic seat and lid
Single squatting plate with 5 litre P.V.C. automatic flushing cistern
White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar tap
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :
One urinal basin with 5 litre white P.V.C. automatic flushing cistern
Providing and fixing PVC waste pipe for sink or wash basin including PVC waste fittings complete.
40 mm dia
Providing and fixing 600 x 450 mm beveled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P brass screws and washers complete.
Rectangular shape 453x357 mm
Providing and fixing PTMT liquid soap container 109 mm wide,125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.
600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms.
Providing and fixing on wall face unplastidsed-PVC(working pressure 4 kgf per sqm) rain water pipes conforming to IS :4985 including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. (SW)
75 mm diameter
110 mm diameter
Providing and fixing on wall face unplasticised -PVC molded fittings/accessories for unplasticised-PVC rain water pipes conforming to (S:4985 including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for therma expansion.(SW)
Coupler
Shoe plain, 110mm shoe
Providing and fixing unplasticised -PVC pipe clip of approved design to unplasticised PVC rain water pipe by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing on cement mortar(1:4) 1 cement: 4corsa sand and making good the wall etc complete.(SW)
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
15 mm nominal outer dia Pipes
20 mm nominal outer dia Pipes
25 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. EXTERNAL WORK
40 mm nominal OD pipes
50 mm nominal outer dia Pipes
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
40 mm nominal bore
50 mm nominal bore
Up to 300 mm dia
15 mm nominal bore
20 mm nominal bore
15 mm nominal bore
15 mm nominal bore
15 mm nominal bore
25 mm nominal bore
150mm diameter
Providing and laying cement concrete 1:5:10( 1 cement: 5 coarse sand:10 graded stone aggregate 40mm nominal size) all-round S.W pipes including bed concrete as per standard design.
150mm diameter S.W pipe
Providing and fixing square-mouth S.W gully trap grade 'A' complete with C.I grating brick masonry chamber with water tight C.I cover with frame of 300x300mm size(inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:
With F.P.S bricks class designation 75
Providing and laying non-pressure NP2 class (light duty) R.CC pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2( 1 cement: 2 fine sand) including testing of joints etc. complete.
150mm dia R.C.C pipe
With F.P.S bricks class designation 75
constructing brick masnory road gully chamber
Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement: 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing and laying Non Pressure NP-4 class (Heavy duty) R.C.C.pi pes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete
450 mm dia RCC pipes.
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level.
300 mm dia
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools,plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level.
300 mm dia
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.
100 mm nominal size dia
150 mm nominal size dia
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.
100 mm nominal size dia
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.
Gravel packing in tubewell construction in accordance with IS: 4097,including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-incharge.
Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge.
200 mm dia
150 mm dia
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.
100 mm dia
150 mm clamp
Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I).
100 mm dia
150 mm dia
Constructing masonry Chamber 60x45x50 cm inside, in brick work in
18.37.1 With common burnt clay F.P.S.(non modular) bricks of class
Development of tube well in accordance with IS : 2800(part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully develo ped, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.
S/F/F 1 H.P. Cromption or any other apprioved make Motor and ISI make automatic starter mounted on a common wooden board etc. all complete job.
S/F/F 2 H.P. Cromption or any other apprioved make Motor and ISI make automatic starter mounted on a common wooden board etc. all complete job.
Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.
STEEL ALMIRAH WITH 4 SHELVES (L)900MM X (D)450MM X (H)1980MM. STOREWELL WITH 4 SHELVES GAUGE: BODY: 22 GAUGE *DOORS: 20 GAUGE, The Product Should be Certified Company BIFMA,JSO 50001, Green Guard/Green PRO, Sedex,AlOTA, IGBC, AGSI,FSC & PEFC
TABLE WITH SIDE TABLE :- Providing and fixing Table with side table : Table with side table : Table and side Table top made 36 mm thk PLPB Board with balancing laminate below the top. Under structure made of 36/ 25 mm thk BSL PLPB . Table having wooden keyboard and metal CPU Troley and one 2D + 1 F mobile pedestal.
High Back Chairs for cabins :-Proving and placing in position heigh back revolving chair of seat & back made up of hi- quility leatherite made up of 1.2+/-0.1cm thick hot press plywood measured. Chair upholstered with leatherite and moulded foam. The foam is desinged with contoured lumber support for extra confort. The armrest is made of black PP armrest. The front center tilt mechanism is designed with features like 360 degree revolving type, chair has lift mechanism for height adjustment resting on PP base dia 60-61 cm with surprior quality five castor wheel pronged with steel strip twin castor wheels and centre title mechanism etc. The product should be from BIFMA compliance and FSC certified company etc. complete as per the approved photograph and as per the direction of Engineer - in -Charge.
Reception Table -Size- 2400x750x950mm. Table top 25mm with 10mm glass which will stand on ss studs.table with both side 3 drawers. The Product Should be Certified Company BIFMA,Green Guard and as per direction of E/I
Mid Back Chair- (Back Height-495xBack Width-470)mm & (Seat Depth 485xSeat Width-475)mm witlh Min-Max Heloht (410-470)mm. Nylon hase chair with push back mechanism & Fix handle. Back & seat cover cushlon chair uphlostered in fabric & adjustable amrest locks any posltlon. Syncro mechenism with locking system and five star Nylon base with nylon casters. Seat & Back made up of 14mm thick boiling water proof plywood os ISI303. Chair rotates a full 360 degree in either direction for ease of motion. |Standard on every executive with task chair & controls rate and ease with which chair reclince t difforcnt welght and strengths of users. Quick and easy adjustment regulated height of chair rolativo to floor. Back reclines at A 2-t0-1 rotio to the seat. 5% post consumod rooycled cnlenl & 30% total recycled content. The Product Should be Certifled Company BIFMA,ISO 50001,Green Guard/Green PRO, Sedex, AIOTA, IGRC, AGSI,FSC & PEFC. Color-Black
3 seator/ chrome chair 3 sector chair (Chrome) Made of cushion with high density cold cured self skinned pre moulded foam of 50-60 density the shape plywood . Upholstery is done by using high - pressure pneumatic spray glue and pnematic press over come base & legs etc. The product should be BIFMA, ISO-19001,14001, OHSAS18001 , IGBC, FIRA Certified. as per the approved photograph and as per the direction of Engineer - in -Charge.
Providing and Supply Pitch Roller (Hand Roller, 1.5 tone)
Providing and Supply Grass Cutter (Honda, Petrol Lawn mover)
Group C
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc.as required.
Wiring for light/ power plug with 2x4 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit along with 1 No 4 sq.mm. FR PVC insulated copper conductor single core cable for loop earthing as required.
2x2.5 Sq.mm +1x2.5 Sq.mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
2 x 6 sq.mm + 1 x 6 sq.mm. earth wire
Supplying and fixing PVC/G.I box of 200mm x 250mm x 60mm deep on surface or in recess with suitable size of phenolic laminated sheet cover in fornt including painting etc as required.
Supplying and fixing suitable GI Box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin, 15/16 amps modular socket outlet and 15/16 amps modular switch, connection, painting etc. as required. (for power plug ).
Supplying and fixing suitable size G.I Box with modular plate and cover in front on surface in recess including providing and fixing 3 pin, 5/6 amps modular socket outlet and 5/6 amps modular type switch, connection, painting etc., as required. (for light plugs to be used in non residential buildings ).
4 way ( 4 + 12 ), Double door, horizontal type
6/32 amp single pole
40 A to 63 A, TP&N
6 A to 32 A, SP&N
25/100 Amp, 10 KA
400 A, 50 KA, FPMCCB
Providing and fixing following capacity four pole ON-load/ panel mounted changeover switches inside the existing cubical panel board including drilling holes in cubicle panel, making connections etc. as required.
Supply and fixing of fabricated Electrical control panel of cubical construction, floor/wall mounted type, fabricated out of 16 SWG CRCA sheet, compartmentalised with hinged doors, dust and vermin proof, powder coated painting of approved shade after 7 tank treatment process, cable alley, internal wiring, earth terminals, Bus bar Chamber, insulator and complete in all respect etc and panel manufactures must be approved by CPRI. (But without RYB inicator, ammeter, voltmeter, inter-connection copper conductor cable/solid copper strip, switchgears etc.)
Supply and fixing panel mounted digital multimeter (Voltmeter & ammeter) including CT coil and RYB pilot indictor in the existing cubical panel board including drilling holes in the panel board making connections etc as required.
Supply and installation of regular/standard model A.C. ceiling fan of 1200 mm sweep with service value (CM/MM) minimum 4.00, Air delivery minimum 210 cum/min including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated copper conductor etc as required.
Supply and Installation of 300 mm 230volt AC exhaust fan in the existing opening including making good the damage connection testing commissioning etc as required.
12 watt LED lamp
Supplying and fixing recess/surface mounted 23/24 (1ft X 1ft) watt LED downlighter complete with integrated electronic driver & LED directly on ceiling/false ceiling including connection with 1.5 sq.mm FR PVC insulated copper conductor cable and earthing the body etc. as required.
300 sq. mm, 3.5 core
95 sq. mm, 3.5 core
Providing chemical/mineral maintenance free earthing system comprising of copper coated earth electrode 3 metre length and 17.2 mm outer dia along with 25 kg earth conductivity enhancing back fill mineral compound for earth electrode to fill up the excavated earth and earth inspection pit etc. as required.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
SITC of high-quality integrated LED Flood Light with a minimum system lumen of 70K Lm and system wattage not exceeding 500W(+5%) with a minimum efficiency 140 lumen/watt. CCT of 5700K with SDCM of < 5 and CRI : 70. The housing should be of non-corrosive high-pressure die-cast aluminum to with stand extreme environments. It should have corrosion resistant powder coating to pass NSS of 500 Hrs. with PF > 0.95. Lifetime of 75K hours @L70. Product should be suitable for continuous operation (10-12 Hrs. per day). The Ingress protection should be minimum IP 66 with an IK rating of 08. Optical and control gear compartments shall be maintainable/replaceable without impacting the LED units. The access to the optical and the gear compartment should be separate. While accessing the gear compartment, the optical compartment should not be accessible. The Luminaire should have a 20 KV /10 KA SPD duly bolted in the Luminaire. The SPD should be able to sustain a minimum 15 hits of 10KA rating i.e. Total of 45 hits across all the three modes as per IEEE 62.41.2. The Luminaire should have a breather to ensure that air balance inside and outside of the Compartment .The luminaire should be of Class B Serviceability. The wattage of each LED should be greater than 1 watt and less than 3 Watt. Only high power Single white LED chip with ceramic based suitable for outdoor use is allowed. Multi Chip, array multi die, mid power, Integrated arrays and COB’s are not permitted. The High power LED used in the luminaire shall be SMD type only of make LGIT, Lumileds, Osram, Nichia, and CREE & no other make. The luminaire should be capable of withstanding voltage stress of 440V for 8 Hrs., should have an auto shutdown @ 325V and have an auto recovery feature. The Drivers should be a potted driver not a printed circuit board without casing, mounted inside the luminaire. The luminaires should have a breather ensuring a stable optical and thermal management. The weight of the luminaire should not be more than 12 Kg.
SITC of high-quality integrated LED Flood Light with a minimum system lumen of 74K Lm and system wattage not exceeding 500W(+5%) with a minimum efficiency 145 lumen/watt. CCT of 5700K with SDCM of < 5 and CRI : 70. The housing should be of non-corrosive high-pressure die-cast aluminium to with stand extreme environments. It should have corrosion resistant powder coating to pass NSS of 500 Hrs. with PF > 0.95. Lifetime of 75K hours @L70. Product should be suitable for continuous operation (10-12 Hrs. per day). The Ingress protection should be minimum IP 66 with an IK rating of 08. Optical and control gear compartments shall be maintainable/replaceable without impacting the LED units. The access to the optical and the gear compartment should be separate. While accessing the gear compartment, the optical compartment should not be accessible. The Luminaire should have a 20 KV /10 KA SPD duly bolted in the Luminaire. The SPD should be able to sustain a minimum 15 hits of 10KA rating i.e. Total of 45 hits across all the three modes as per IEEE 62.41.2. The Luminaire should have a breather to ensure that air balance inside and outside of the Compartment .The luminaire should be of Class B Serviceability. The wattage of each LED should be greater than 1 watt and less than 3 Watt. Only high power Single white LED chip with ceramic based suitable for outdoor use is allowed. Multi Chip, array multi die, mid power, Integrated arrays and COB’s are not permitted. The High power LED used in the luminaire shall be SMD type only of make LGIT, Lumileds, Osram, Nichia, and CREE & no other make. The luminaire should be capable of withstanding voltage stress of 440V for 8 Hrs., should have an auto shutdown @ 325V and have an auto recovery feature. The Drivers should be a potted driver not a printed circuit board without casing, mounted inside the luminaire. The luminaires should have a breather ensuring a stable optical and thermal management. The weight of the luminaire should not be more than 12 Kg.
Supply, Programming and Commissioning of Outdoor type external lighting CCMS Feeder Panel for Remote Management, Switching, Multistep Dimming and Monitoring of Streetlights using group control system to be supplied considering 1 feeder Pillar cabinet for 10KW LED Load, Central Dimming required from group controls. The dim level commands to the luminaires shall be generated from the LMS equipment installed in the electrical cabinet without any additional wires or pilot lines & minimum 8 dynamic steps should be there excluding ON & OFF. All the luminaires in the segment shall have the same dim level as per the command from the LMS or local trigger. Dimming commands from the mains power cabinet shall not be interrupted by any intermediary luminaire failures between poles. Luminaires shall fall back to 100% light output if there any interruption in dimming commands. Lighting cabinets/feeder pillar to be connected independently to lighting management system cloud server through GPRS/Ethernet with open internet must have following features: a) Automatic (with a timer), remote (with GPRS/GSM) and manual switching option b) Remote energy measurement c) Near real time monitoring d) Alarms and report generation e) Emergency override locally and remotely f) Web based user interface with integrated visual maps g) Data security and secured system access h) Prevent unauthorised physical access to the street light control box i) secured 128 Bit encrypted communication between server and street light feeder panel.
Erection, Testing & Commissioning of the 16m Sports Highmast Pole with Ladder Supply of foundation bolts manufactured from special steel along with nuts, washers, anchor plate and common templateHigh mast with the help of suitable tools and plants, wiring of luminaires with all wiring materials like PVC insulated PVC sheathed flexible cable of suitable copper conductor cores of 2.5 sq. mm, lugs and all labour.
SITC of Total 48 KW HYBRID SOLAR SYSTEM(or as per Requirement of Backup Time) WITH 5 HOURS BACK Up with Inverter (48KW HYBRIDE INVERTER (WARRANTY 5 YEARS),.LITHIUM BATTRY 200 AH Capacity 5 YEARS WARRANTY. CYCLE 3000 TIMES),Structure(STRUCHER 5 FEET./3 FEET GI STUCHER),Nut Bolts etc ( ALL WIRING. DC DVR. AC DVR.COMPLETE WIRING WITH ALL APPLIANCE included)
Supplying and fixing following types LED Flood light with minimum efficacy 100 lm/w in die cast aluminium housing, toughened glass, IP 66 protection and complete with electronic driver etc on pole/building including connection earthing the body etc as required.
SITC of mounting Channel in which LED flood light can mount for illumination of court.Mounting Stracture should have Proper provision of light holding.
Supply and fixing of TLL 50WATT all in one street light along with MONo Crystalline 50 Wp solar panel and 308 wh Lithium battery aluminium housing , LED rating -50000Hr@LM70, Efficacy Lumen /watt> 130,CRI->70, charge controller. Type MPPT, SENSOR Type -PIR Dusk to down Operation,TLL-jupitor-AIO50
Single arm 1500 mm
315 KVA, Copper wound, Energy Efficiency Level-2
CCTV Network Camera Bullet 4 MP (Brand - Hikvision / Bosch / Honeywell) Image Sensor - 1/3" Progressive Scan CMOS, Shutter Speed - 1/3s to 1/10,000 s, Lens - 2.7mm, 4mm, 6mm @ F2.0angle of view: 106°(2.7mm), 83°(4mm), 55.4°(6mm), Day &Night - IR cut filter with auto switch, White Balance - Automatic/Manual, Video Compression - 4/MJPEG/H.264+, Max. Resolution - 2688×1520, Communication Interface - 1 RJ45 10M/100M Ethernet port, Base T
CCTV Network Camera Dome 4 MP Image Sensor - 1/3" Progressive Scan CMOS, Shutter Speed - 1/3s to 1/10,000 s, Lens - 2.7mm, 4mm, 6mm @ F2.0angle of view: 106°(2.7mm), 83°(4mm), 55.4°(6mm), Day &Night - IR cut filter with auto switch, White Balance - Automatic/Manual, Video Compression - H.264/MJPEG/H.264+, Max. Resolution - 2688×1520, Communication Interface - 1 RJ45 10M/100M Ethernet port, Base T
Supply / Installation and Commissioning of 24 Port Network Switch GIGA PoE,IEEE 802.3at and IEEE 802.3af Power over Ethernet (PoE) compliant,24x10/100/1000 Mbps Auto-MDIX PoE ports,Provides up to 30 watts per PoE port,PoE power budget 370W,4 KV surge protection for PoE ports,IEEE 802.3x flow control support,Plug-and-play installation,8.8 Gbps switching fabric,2.75 Mbits RAM Data Buffer,4K MAC address entries,Sturdy metal enclosure
1 run of cable
Hard disk 6 TB
12U Network Rack
Display : Screen size – 42 inch or above (LG/Sony/ Samsung/ Philips), Panel Technology IPS, Surveillance Monitor
32 bit microprocessor based Intelligent Addressable Fire Alarm Control panel with 4 loops with battery back up. The panel would be modular, decentralized, with The panel shall be consisting with minimum 240 character LCD display and for networking. The Panel would be able to record atleast 60,000 events history. Each loop would be capable to have atleast 250 addressable detectors and addressable devices with up to 3.5km loop length. Make: Schrack Seconet (Vds approved)
1 KVA LINE INTERACTIVE UPS WITH 30 MIN BATTERY BACK UP
Supplying and fixing Intelligent Addressable type multicriteria detector with base for use as heat or smoke or combined both with automatic electronic addressing, microprocessor type with builtin integrated short circuit isolator including testing, commissiong etc as reqd.
Supplying and fixing Intelligent Addressable type Heat detector with base with automatic electronic addressing, microprocessor type with builtin integrated short circuit isolator including testing, commissiong etc as reqd.
Sypplying and fixing Intelligent Addressable Manual Call Point having inbuilt short circuit isolator i/c testing and commissiong etc as reqd.
Addressable sounder with interface module, power supply for suonder and programmable by software having integrated short circuit isolator & having operating temperature -10⁰C to + 55⁰C
Analogue Addressable Control module with IP66 casing containing four relay outputs, each containing a potential-free DPDT contact with a fail-safe and in-built short circuit isolator The ambient temperature range shall be -20C to +60C.
Duel LED Response Indicator (LOCAL)
Supplying and laying of 2x1.5 sq.mm. ISI marked copper armourd conductor cable with gland scoket and other wiring accessories on the existing surface/tray/shaft etc as reqd
Quantity :
Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring,earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required :
25 mm dia
80 mm dia
150 mm dia
Single headed stainless steel
150 mm dia
80 mm dia
150 mm dia
Stainless steel (Grade 304)
Stainless steel (Grade 304)
2 way-100 mm dia M.S. Pipe
Supply and fixing air vessel made of 250 mm dia 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement of 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthatic enamal paint approved shade as required.
Providing and fixing following size Pressure gauge (0-15 Kg/Cm2) complete with shut off valve duly calibrated before installation complete as required & as per enclosed specification. 150mm dia.
Description of Work
12.5 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, made of Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16mm thick fire retardant PVC film on the face side and 12micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around
Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade:
A=n*2*(L+B)*H
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:
Providing & Laying 2.0 mm thick Vinyl Flooring ( Armstrong / Wonderfloor, etc )
DGM BSBCCL Bhagalpur
DESCRIPTION
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit, with modular type switch, modular plate, suitable size G.I. box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc.as required
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc.as required.
Wiring for twin control light point with 1.5 sq. mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box etc as required
Wiring for light/ power plug with 2x4 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit along with 1 No 4 sq.mm. FR PVC insulated copper conductor single core cable for loop earthing as required.
Metre
Metre
Metre
Metre
Metre
Supplying and fixing PVC/G.I box of 200mm x 250mm x 60mm deep on surface or in recess with suitable size of phenolic laminated sheet cover in fornt including painting etc as required (Adopter box above each D.B).
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps "C" curve, SP MCB, in sheet steel Enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and ommissioning etc. as required.
Supplying and fixing suitable size G.I Box with modular plate and cover in front on surface in recess including providing and fixing 3 pin, 5/6 amps modular socket outlet and 5/6 amps modular type switch, connection, painting etc., as required. (for light plugs to be used in non residential buildings )
Supplying and fixing 12 modules GI box along with moduler base & cover plate surface or in recess including providing and fixing of 4 nos 6 pin 15/16 amps socket outlet with 4 no 15/16A moduler type switch ,connection etc. as required.
Main Bus Bar: 4 strip 300 amp bus bar made of electrical grade copper strip enclosed in separate bus bar chamber, provided with DMC/ SMC bus bar support duly insulated with heat shrinkable sleeves in distinct colours as reqd: 1 set (1 Amp per sqmm.)
Providing and fixing MV danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Providing chemical/mineral maintenance free earthing system comprising of copper coated earth electrode 3 metre length and 17.2 mm outer dia along with 25 kg earth conductivity enhancing back fill mineral compound for earth electrode to fill up the excavated earth and earth inspection pit etc. as required.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required
Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required
P/F 4.00 mm dia.copper wire on surface or in recess for loop earthing along with existing surface /recess for loop earthing along with existing surface/recessed conduit /submain wiring/cable etc required.
Metre
Supply and fixing 100 mm dia medium class GI pipe etc as required.
Supply and Installation of regular/standard module AC ceiling fan of 1400 mm sweep including wiring the down rod of standard length 9 upto 30 cm ) with 1.5 sq mm FR pvc insulated copper conductor etc as required.
Supply and Installation of 300 mm 230volt AC exhaust fan in the existing opening including making good the damage connection testing commissioning etc as required.
Supply and installation of 600 mm, 230 V A.C. wall mounted Air circulator, heavy duty fan including fixing the bracket, making onnection, testing, commissioning etc as required.
Supplying and fixing indoor recess mounting 36 watt LED flat panel luminaire suitable for armstrong/grid ceiling and complete with electronic driver etc. directly on false ceiling including connection with 1.5 sqmm fR PVC insulated copper conductor cable and earthing the body etc as required.
Supplying and fixing 90 watt LED type FLOOD light with die cast aluminium housing for ingress protection of IP65 and complete with all accessories etc and connection with FR PVC insulated copper conductor cable and earthing the body etc. as required
Meter
Meter
Supply and fixing of fire extinguisher, ABC Type 4.00kg. Capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.
Supply and fixing of shock treatment chart (prescribed under I. E. rules) duly framed with glass and supported from back with hard board or soft board with supply of all material, labour, T&P for proper completion of work.
Supply and fixing of fire bucket, round bottom made of GI sheet 9-11 litres capacity duly painted as per fire brigade design, supported on hanging bracket chained and locked, initially filled with fine river sand, water as per direction of Engineer-in-Charge.
SITC AC split(1.5 ton) with stabilizer ISI standard as per specification 5 star inverter AC.. ( Make- blue star/mitsubishi/lg/carrier/Hitachi)
Supplying and fixing modular type 25 amps A.C. unit box with ON/OFF MCB on surface or in recess complete with connections, testing and commissioning etc as required.
Extra copper piping electrical wire for split AC
Supplying and drawing of UTP 4 pair CAT-6 LAN cable in the existing surface/recessed steel /PVC concuitas required.
Category 6 UTP Patch Cords - 1 Mtr Standard Colour - Blue, Grey, Yellow, RJ45 Plug - Polycarbonate plug, Current Rating - 1.5A max, Insulation Resistance - 500MΩ/km(min)@500 Vdc, Contact Resistance - 15 mΩ (max) per contact
Category 6 UTP Patch Cords - 2 Mtr Standard Colour - Blue, Grey, Yellow, RJ45 Plug - Polycarbonate plug, Current Rating - 1.5A max, Insulation Resistance - 500MΩ/km(min)@500 Vdc, Contact Resistance - 15 mΩ (max) per contact
24-port GbE Smart Managed Switch with GbE Uplink Interfaces-24 Ports 10/100/1000Mbps+4 SFP;Port Standards & Functions-IEEE 802.3 10BASE-T Ethernet (twisted-pair copper),IEEE 802.3u 100BASE-TX Fast Ethernet (twisted-pair copper),IEEE 802.3ab 1000BASE-T Gigabit Ethernet (twisted- pair copper),IEEE 802.3az compliance Auto-negotiation,IEEE 802.3x Flow Control; Full/Half Duplex-Full/half duplex for 10/100 Mbps speeds,Full duplex for Gigabit speed;Media Interface Exchange Auto MDI/MDIX adjustment for all twisted-pair ports;Switching Capacity 56 Gbps; Transmission Method Store-and-forward; MAC Address Table 16,000 entries per device, Maximum 64 bytes packet forwarding rate 41.7 Mpps,Packet Buffer Memory 1.5 MB,Maximum Power Consumption 22.45 watts, Standby Power Consumption 17.84 W/240 V, Acoustics 0 dBA Heat Dissipation 76.55 Btu/hr, Operating Temperature -5 to 50 ˚C (23 to 122 °F), Storage Temperature -20 to 70 ˚C (-4 to 158 °F), Operating Humidity 0% to 95% non-condensing, Storage Humidity 0% to 95% non-condensing, Diagnostic LEDs Link/Activity/Speed (Per 10/100/1000 Mbps port), Certifications CE (LVD) BSMICCC, C-Tick. Netgear / D-link/ Cisco.
Category 6, UTP 24-Port Patch Panel Size - 482.6mm x 44.2 (19’’ x 1U), Panel Material - Steel-fully powder coated, Unshielded - RJ 45, Plug Insertion Cycle - 750 times DC Resistance- 72Ω max, Voltage Rating - 72 Vdc max, Current Rating - 1.5A max
Supply fitting fixing Rack 19" 12U fully powder coated complete etc as required with complete accessories (5 amp x 6 socket, wire manager, rack fan) VALRACK/ Netrack make.
Supplying and fixing of RJ 45 computer socket suitable for Cat 6 on module GI box along with base & cover plate in surface or in recess including making connection, soldering etc. as required.
Smart-UPS On-Line, 30 kW /30 kVA with 30 minutes Backup 12 V 42 AH SMF Battery UPS Toplogy Double Conversion On-Line, Power Rating (VA / Watts) 30000Watts/30000VA, Form Factor Rack/Tower Convertible; Output Power Capacity 30000 Watts/30000 VA, Max Configurable Power 30000Watts/30000VA, Nominal Output Voltage 230V, Output Voltage Note Configurable for 220 : 230 or 240 nominal output voltage, Efficiency at Full Load 94.00%, Output Voltage Distortion Less than 3%,Output Frequency (sync to mains) 50/60 Hz +/- 3 Hz,Crest Factor 03:01,Waveform Type Sine Wave, Output Connections (1)*Hard Wire 3-wire (8)*(H N + G) IEC 320 C13(8),Bypass Built-in Bypass, Output Short Circuit Protection Yes,Parallel Redundancy (Option) 1 + 1, Nominal Input Voltage 230V,Input Power Factor>0.98,Input Frequency 40-70Hz,Input Connections Terminal Block, Protection Thermal Circuit Breaker (250VAC/20A), Input voltage range for main operations full load 160 - 285V, Input voltage range for mains operation half load 160-285V, High Voltage withstand Capability 420 VAC, Green Mode Range 210-250 VAC (230 V), Battery Type Mintenance - free sealed Lead-Acid battery with suspended, electrolyte. 12V 42 Ah SMF battery for 30 Min Battery Back up.
SITC of 2MP IR Indoor Dome Fixed Camera- 1/2.8"Progressive Scan CMOS, 1920 × 1080 at 25fps, 2.8 mm Fixed lens, Color: 0.01 Lux at F1.2, ICR, ONVIF, support H.265, H.264, MJPEG, DWDR, 3D Digital Noise Reduction, Tripple individually configurable stream, 12 VDC & PoE, IR range: 40m, IP67, IK10, Edge Anlalytics- Line crossing detection, intrusion detection, Motion detection, video tampering, UL, CE, FCC certified. (DS-2CD3121G0-I (2.8 mm) (Approved Makes: Hikvision/ Honeywell/ Bosch)
SITC of 2MP IR Bullet Fixed Camera -1/2.8"Progressive Scan CMOS, 1920 × 1080 at 25fps, 2.8 mm Fixed lens, 0.01 Lux at F1.2, 0 Lux with IR, ICR, ONVIF (PROFILE S), support H.265, H.264, MJPEG, DWDR, 3D Digital Noise Reduction, Three individually configurable stream, 12 VDC & PoE, IR range: 40m, IP67, Edge Anlalytics- Line crossing detection, Intrusion detection, Motion detection, Scene change detection, Video tampering, UL, CE, FCC certified. (DS-2CD3021G0-I (2.8 mm) (Approved Makes: Hikvision/ Honeywell/ Bosch)
SITC of 64 ch Network Video Recorder - Connect Up to 64 IP Cameras, Dual OS, Up to 12 Megapixels Resolution, Two independent HDMI outputs, one HDMI output of 4K resolution,1 VGA output with output upto 1920 × 1080, Support H.265, MJPEG, Supports N+1 hot spare system,Supports RAID0, RAID1, RAID5, RAID6 and RAID10 ,Supports HDD hot swap, Supports Dual Power-Redundant, Incoming Bandwidth 320 Mbps, 8 SATA Hard Disks, ANR Technology, 8 SATA interfaces for 8 HDDs and capacity of each HDD upto 6TB, 3 × USB at least 1 × USB with 3.0, Alarm I/O 16/4, RS-485, RS-232, 2 RJ-45 10 /100/1000 Mbps self-adaptive Ethernet interface, Multiple network monitoring: Web viewer, CE, FCC, UL certified. (DS-7764NI-I8) (Approved Makes: Hikvision/ Honeywell/ Bosch)
SITC OF 32" LCD 24X7 Surveillance Monitor
SITC of 16 port Unmanaged Network PoE Switch: 24 port PoE Switch with PoE standard of IEEE 802.3af , IEEE 802.3at, PoE port, Uplink ports (DS-3E0326P-E) (Approved Makes: Hikvision/ Honeywell/ Bosch)
SITC OF Cat-6 Cable: UTP CAT 6, 305 meters,Core diameter: 0.53mm,OFC,CM,white (Approved Makes: Hikvision/ Honeywell/ Bosch)
SITC of 6TB Surveillance Hard Disk (ST6000VX0023) (Approved Makes: Hikvision/ Honeywell/ Bosch)
19" 6U Rack for Switches complete as required
Camera installation and Connectivity.
In-ceiling speaker 6" ceiling loudspeaker. 6/3W @ 100V, 100-15,000Hz, 93dB 1W 1M. Dimensions (L x H): 188mm x 76mm, mounting hole 170mm diameter. White( Surface mount speakers to be provided if no provision for ceiling speakers) Make: Cloud UK, Alfatron, Biamp.
Media player, mixer amplifier with Bluetooth. Supplied with remote control. On board tuner and MP3 player. Inputs: Front panel mic. input with priority function, rear panel balanced mic. input with phantom power. Emergency input function. Dual RCA line inputs. Outputs: RCA aux out. 60W at 70/100V and 4-16 Ohms. 24V backup power input.Make:Biamp, Alfatron.
LCD portable projector, 5,000 lumens, WUXGA, 16,000:1 contrast ratio, Aspect Ratio:16:10, Lens (Throw Ratio)1.6x manual zoom (throw ratio: 1.09–1.77:1), manual focus F 1.60–2.12, f 15.30–24.64 mm, Make: Panasonic, Christe, Barco.
113" Diagonal, 16:10 Aspect Ratio, black border on all sides, matt white fabric, motorised with remote and heavy duty Motor. Make AV-craft, grandview.
Projector ceiling mount 1x2, adjustment option. Make TS, B-Tech, Eqv.
Cable Manager with Power socket and HDMI. Make Logic/ Legrand.
C–HM/HM/ETH–50 ( 50 feet) make Kramer / Extron.
Equipment Rack, with Hardware and lock. Make Valrack/ Custom / Eqv.
SITC of 50 LPH RO Water Purifier alng with RO-AUTO MAX 50 lph, hdrophenumatic tank-10 LPH, Faucet-1 nozzle, accessories- clip, inlet & outlet pipe etc.
Description of Work
Earth work in excavation over areas ( exceeding 30 cm in depth. 1.5 m in width as well es 10 sqm on plan) including disposal of excavated earth , lead upto 50 m and lift upto 1.5 m; disposed earth to be levelled and neatly dressed.
Extra for every additional lift of 1.5 m or part thereof in :
Closed timbering over Area
Supplying and Filling in plinth with local sand and under floors including, watering, ramming consolidating and dressing complete.
Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling and plugging 12 mm diameter holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floor.
Providing designation 100 A one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as per building specification and direction of E/l,
Providing and laying in position cement concrete of specified grade.
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana /Ordinary Portland /Portland Slag cement
All work above Plinth level upto floor V Level : Concrete of M-25 grade with minimum cement content of 330 kg/cum
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete.
TMTC-500- 08 mm dia.
TMTC-500- 10 mm dia.
TMTC-500- 12 mm dia.
TMTC-500- 16 mm dia.
TMTC-500- 20 mm dia.
Centring and shuttering including strutting, propping etc. and removal
Foundations, footings, bases of columns etc. for mass concrete.
Suspended floors, roots, landings, balcnies and access platform..
Lintels, beams, plinth bams, griders, bressumers and contilevers.
Columns,Pillars, Piers, Abutments, Posts and Struts
Weather shade,Chajjas, corbels etc. including edges
Brick work with fly ash bricks as per IS 12894(2002) & IS 3495 in foundations and plinth in :
Brick work with fly ash bricks as per IS 12894(2002) & IS 3495 in foundations and plinth in
Brick work with bricks of class designation 100A in foundations and plinth in :
Half brick masonry with bricks of class designation 100A
Kota stone slab flooring over 20 mm (average ) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete . Base with 1:1:1 (1 lime : 1 surkhi: 1 coarse sand ) / 1:4 (1 cement: 4 coarse sand )
Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer) of ist quality conforming to IS : 15622 of approved make in colours such as white , Ivory , Grey , Fume Red , Brown , laid on 20 mm thick Cement motar 1:4 (1 cement: 4 coarse sand ) including pointing the joints with white cement and matching pigment etc., complete.
Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth.
12 mm cement plaster on rough side of single or half brick wall of mix : (1 : 6)
15 mm cement plaster on rough side of single or half brick wall of mix : (1 : 6)
15 mm cement plaster(1:3) with punning
Providing and applying white cement based putty of average thickness 2 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade:
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:
Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile),...
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required...
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge.
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
Supplying and fixing-rolling shuters of approved make.made of required size of M.S.Iaths interlocked together through their intire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arragements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.
Providing and fixing ball bearing for rolling shutters
Extra for providing mechanical device chain and crank operation for operating rolling shutters:
Detailing,Engineering,Manufacturing,Painting,Supply,transportation & Erection of steel structure system for PEB structure with Z purlin , sagrods runners , cross bracing clip fastners using 350 MFa grade Hitensible steel. All fabrication work shall be done off-shore (not on site) bolt in connection type and only site assembly shall be done with the help of high strength bolts (HSFG) . All testing and inspection facility shall be in-house to ensure 100% checking and inspection prior to shipment from the fabrication shop. All structure steel shall be min 350 Mpa yield strength of E350 grade or equivalent grade but not less than 350 Mpa as per approval of Engineer in-charge. All anchor bolts shall be high strength HSFG bolts for assembly and electro-galvanized of min. 8.8 grade. Entire steel structure shall be surface finished shot blasted as per SA 2 1/2 followed by applying 2 coat of epoxy base primer each coat of min. 35 micron and 2 coat of final finish epoxy paint shall be applied each of min. 35 micron thickness on entire structure prior to shipment. Final painting can be done at site during installation.All design & drawings shall be per-approved by Engineer in-charge
Supply & fixing of Hi-Rib profiled sheeting 1000-1030 cover width, 28/30 mm crests @ 250-255 mm c/c manufactured out of 0.55 mm TCT hi-tensile Multi Cloured Galvalume steel (AZ-150 gsm. Aluminium-Zinc alloy metallic coating of total both sides 550 Mpa yield stress as per AS-1397). The sheet shall have wide pans with 3 small stiffening ribs for effective water shedding and special male/female ends with full return legs on side laps for purlin support. The male end of the sheet shall have anti-capillary flute at side lap to prevent leakages. The sheet shall be passivated and clear resin coated. The sheet shall be fixed by means of galvanised self-drilling self tapping fasteners ( 12-14x55 with EPDM seals). The sheet shall be supplied in lengths maximum upto 6-12 Mtrs long to suit site dimensions
Supply and fixing of Multi Coloured galvalume sheet with screws on cladding.
Supply and fixing of Flashing /Ridge/ and gable flashing colour coated up to : Supply and fixing of Flashing /Ridge/ and gable flashing colour coated up to : 300mm - 500 mm girth.
Providing & Fixing GE plastic 600mm dia Turbo Vents of approved make and laying in position as per drawing or as directed by Engineer-in-charge
Providing & Fixing clear polycarbonate sheet 1000 mm wide & 1.5 mm thick of approved make and laying in position as per drawings matching profile with galvalium sheet or as directed by Engineer-in-charge
Supply and fixing of Colour coated gutters with gutter supports, sealnts
Providing & Fixging MS rain water pipe 100 x 125 mm of approved make in position as per drawings or as directed by Engineer-in-Charge.
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T"...
Providing & Laying 2.0 mm thick Vinyl Flooring ( Armstrong / Wonderfloor, etc )
Providing and fixing soil, waste and vent pipes : Sand cast iron S&S pipe as per IS: 1729
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.
Providing & Grouting of dowel tubes / Shear keys / Joints of precast members with M-60 grade cementitious grout (Non Shrink) of approved make by suitable means ( Free flowing /pump),curing etc. Complete as per directions of Engineer- in-charge. (The payment shall be made on the basis of actual weight of approved grout injected.)
Carriage of materials
Extra Cost of Materials
Providing and fixing water closet squatting pan (Indian type W.C.pan ) with 100 mm sand cast Iron P or S trap, 10 litre low fixtures complete, including cutting and making good the walls andlevel white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS :7231, with all fittings and floors wherever required :
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :
Providing and fixing wash basin with C.I brackets, 15mm C.P brass pillar taps, 32mm C.P brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :
Providing and fixing PVC waste pipe for sink or wash basin including PVC waste fittings complete.
Providing and fixing 600 x 450 mm beveled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P brass screws and washers complete.
Providing and fixing PTMT liquid soap container 109 mm wide,125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.
Providing and fixing on wall face unplastidsed-PVC(working pressure 4 kgf per sqm) rain water pipes conforming to IS :4985 including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. (SW)
Meter
Meter
Providing and fixing on wall face unplasticised -PVC molded fittings/accessories for unplasticised-PVC rain water pipes conforming to (S:4985 including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for therma expansion.(SW)
Providing and fixing unplasticised -PVC pipe clip of approved design to unplasticised PVC rain water pipe by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing on cement mortar(1:4) 1 cement: 4corsa sand and making good the wall etc complete.(SW)
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
metre
metre
metre
Providing and laying flanged C.I. standard specials such as tees,bends, collars, tapers, caps etc., suitable for flanged jointing as per IS : 1538 :
quintal
Providing and fixing brass stop cock of approved quality:
Providing and fixing C.P brass bib cock of approved quality conforming to IS:8931
Providing and fixing C.P brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.
Providing and fixing C.P brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931
Providing and fixing gun metal non- return valve of approved quality (screwed end)
Constructing brick masonry manhole in cement mortar 1:4(1 cement: 4 coarse sand) R.C.C top slab with 1:2:4 mix (1 cement:2 coarse sand: 4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement: 4 coarse sand:8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3( 1 cement: 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement: 2 coarse sand:4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design:
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools,plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level.
metre
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.
metre
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.
Gravel packing in tubewell construction in accordance with IS: 4097,including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-incharge.
Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge.
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.
Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I).
Constructing masonry Chamber 60x45x50 cm inside, in brick work in
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit, with modular type switch, modular plate, suitable size G.I. box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc.as required
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc.as required.
Wiring for twin control light point with 1.5 sq. mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box etc as required
Wiring for light/ power plug with 2x4 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit along with 1 No 4 sq.mm. FR PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface /recessed PVC conduit (for equipment wiring round flexible copper cable as per required)
Metre
Metre
Metre
Metre
Metre
Supplying and fixing PVC/G.I box of 200mm x 250mm x 60mm deep on surface or in recess with suitable size of phenolic laminated sheet cover in fornt including painting etc as required (Adopter box above each D.B).
Supplying and fixing PVC/G.I box of 75 mm X 75 mm X 50 mm deepdeep on surface or in recess with suitable size of phenolic laminated sheet cover in fornt including painting etc as required (Adopter box above each D.B).
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps "C" curve, SP MCB, in sheet steel Enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and ommissioning etc. as required.
Supplying and fixing suitable size G.I Box with modular plate and cover in front on surface in recess including providing and fixing 3 pin, 5/6 amps modular socket outlet and 5/6 amps modular type switch, connection, painting etc., as required. (for light plugs to be used in non residential buildings )
Supplying and fixing 12 modules GI box along with moduler base & cover plate surface or in recess including providing and fixing of 4 nos 6 pin 15/16 amps socket outlet with 4 no 15/16A moduler type switch ,connection etc. as required.
Supply & fixing 4 way(4+12) double door TP & N, sheet steel, MCB distribution board, 415 volts, on surface/ in recess, complete with tinned copper busbar, neutral link, earth bar, din bar, detachable gland plate, interconnections, phosphatised and powder painted including earthing etc.as required (But without MCB / RCCB / Isolator) light DB
Supply & fixing 4 way(4+12) double door TP & N, sheet steel, MCB distribution board, 415 volts, on surface/ in recess, complete with tinned copper busbar, neutral link, earth bar, din bar, detachable gland plate, interconnections, phosphatised and powder painted including earthing etc.as required (But without MCB / RCCB / Isolator) Power DB
S/F modular blanking plate on the existing modular plate and switch box excluding modular plate as required.
Main Bus Bar: 4 strip 300 amp bus bar made of electrical grade copper strip enclosed in separate bus bar chamber, provided with DMC/ SMC bus bar support duly insulated with heat shrinkable sleeves in distinct colours as reqd: 1 set (1 Amp per sqmm.)
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as per required.
Supplying and fixing Cable end box (Loose wire box, IP43) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240/415 V, on surface /recess complete with testing and commissioning etc. as required.
Providing and fixing MV danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Providing chemical/mineral maintenance free earthing system comprising of copper coated earth electrode 3 metre length and 17.2 mm outer dia along with 25 kg earth conductivity enhancing back fill mineral compound for earth electrode to fill up the excavated earth and earth inspection pit etc. as required.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required
Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required
P/F 4.00 mm dia.copper wire on surface or in recess for loop earthing along with existing surface /recess for loop earthing along with existing surface/recessed conduit /submain wiring/cable etc required.
Supply & Laying of ISI marked aluminium conductor XLPE insulated cable as per IS 7098, & cable & wirE shall be armoured, served, sheathed 1100 volts grade as per Batra Henley / Havells/ Finolex.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation and refilling the trench etc. as required, but excluding sand cushioning and protective covering.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
Supply and fixing 100 mm dia medium class GI pipe etc as required.
Supply and Installation of regular/standard module AC ceiling fan of 1400 mm sweep including wiring the down rod of standard length 9 upto 30 cm ) with 1.5 sq mm FR pvc insulated copper conductor etc as required.
Supply and Installation of 300 mm 230volt AC exhaust fan in the existing opening including making good the damage connection testing commissioning etc as required.
Supply and installation of 600 mm, 230 V A.C. wall mounted Air circulator, heavy duty fan including fixing the bracket, making onnection, testing, commissioning etc as required.
Supplying and fixing indoor recess mounting 36 watt LED flat panel luminaire suitable for armstrong/grid ceiling and complete with electronic driver etc. directly on false ceiling including connection with 1.5 sqmm fR PVC insulated copper conductor cable and earthing the body etc as required.
Supplying and fixing 90 watt LED type FLOOD light with die cast aluminium housing for ingress protection of IP65 and complete with all accessories etc and connection with FR PVC insulated copper conductor cable and earthing the body etc. as required
Supplying and fixing following LED street/ Flood light with die cast aluminium housing for ingress protection of IP65 and complete with all accessories etc on pole/ building including connection and earthing the body etc. as required.
Supplying and fixing following sizes of PVC conduit along with accessories in surface /recess including cutting the wall and making good the same in case of recessed conduit as required.
Meter
Meter
Supply and fixing of fire extinguisher, ABC Type 4.00kg. Capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.
Supply and fixing of shock treatment chart (prescribed under I. E. rules) duly framed with glass and supported from back with hard board or soft board with supply of all material, labour, T&P for proper completion of work.
Supply and fixing of fire bucket, round bottom made of GI sheet 9-11 litres capacity duly painted as per fire brigade design, supported on hanging bracket chained and locked, initially filled with fine river sand, water as per direction of Engineer-in-Charge.
Providing and fixing carbon-di-oxide fire extingushers trolley mounted with all accessories internal discharge tube, high pressure discharge hose, discharge nozzle, suspension bracket, ISI marked as per IS:2878 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.
SITC AC split(1.5 ton) with stabilizer ISI standard as per specification 5 star inverter AC.. ( Make- blue star/mitsubishi/lg/carrier/Hitachi)
Supplying and fixing modular type 25 amps A.C. unit box with ON/OFF MCB on surface or in recess complete with connections, testing and commissioning etc as required.
Extra copper piping electrical wire for split AC
Extra drain pipe split AC
Supplying and drawing of UTP 4 pair CAT-6 LAN cable in the existing surface/recessed steel /PVC concuitas required.
Category 6 UTP Patch Cords - 1 Mtr Standard Colour - Blue, Grey, Yellow, RJ45 Plug - Polycarbonate plug, Current Rating - 1.5A max, Insulation Resistance - 500MΩ/km(min)@500 Vdc, Contact Resistance - 15 mΩ (max) per contact
Category 6 UTP Patch Cords - 2 Mtr Standard Colour - Blue, Grey, Yellow, RJ45 Plug - Polycarbonate plug, Current Rating - 1.5A max, Insulation Resistance - 500MΩ/km(min)@500 Vdc, Contact Resistance - 15 mΩ (max) per contact
24-port GbE Smart Managed Switch with GbE Uplink Interfaces-24 Ports 10/100/1000Mbps+4 SFP;Port Standards & Functions-IEEE 802.3 10BASE-T Ethernet (twisted-pair copper),IEEE 802.3u 100BASE-TX Fast Ethernet (twisted-pair copper),IEEE 802.3ab 1000BASE-T Gigabit Ethernet (twisted- pair copper),IEEE 802.3az compliance Auto-negotiation,IEEE 802.3x Flow Control; Full/Half Duplex-Full/half duplex for 10/100 Mbps speeds,Full duplex for Gigabit speed;Media Interface Exchange Auto MDI/MDIX adjustment for all twisted-pair ports;Switching Capacity 56 Gbps; Transmission Method Store-and-forward; MAC Address Table 16,000 entries per device, Maximum 64 bytes packet forwarding rate 41.7 Mpps,Packet Buffer Memory 1.5 MB,Maximum Power Consumption 22.45 watts, Standby Power Consumption 17.84 W/240 V, Acoustics 0 dBA Heat Dissipation 76.55 Btu/hr, Operating Temperature -5 to 50 ˚C (23 to 122 °F), Storage Temperature -20 to 70 ˚C (-4 to 158 °F), Operating Humidity 0% to 95% non-condensing, Storage Humidity 0% to 95% non-condensing, Diagnostic LEDs Link/Activity/Speed (Per 10/100/1000 Mbps port), Certifications CE (LVD) BSMICCC, C-Tick. Netgear / D-link/ Cisco.
Category 6, UTP 24-Port Patch Panel Size - 482.6mm x 44.2 (19’’ x 1U), Panel Material - Steel-fully powder coated, Unshielded - RJ 45, Plug Insertion Cycle - 750 times DC Resistance- 72Ω max, Voltage Rating - 72 Vdc max, Current Rating - 1.5A max
Supply fitting fixing Rack 19" 12U fully powder coated complete etc as required with complete accessories (5 amp x 6 socket, wire manager, rack fan) VALRACK/ Netrack make.
Supplying and fixing of RJ 45 computer socket suitable for Cat 6 on module GI box along with base & cover plate in surface or in recess including making connection, soldering etc. as required.
Smart-UPS On-Line, 30 kW /30 kVA with 30 minutes Backup 12 V 42 AH SMF Battery UPS Toplogy Double Conversion On-Line, Power Rating (VA / Watts) 30000Watts/30000VA, Form Factor Rack/Tower Convertible; Output Power Capacity 30000 Watts/30000 VA, Max Configurable Power 30000Watts/30000VA, Nominal Output Voltage 230V, Output Voltage Note Configurable for 220 : 230 or 240 nominal output voltage, Efficiency at Full Load 94.00%, Output Voltage Distortion Less than 3%,Output Frequency (sync to mains) 50/60 Hz +/- 3 Hz,Crest Factor 03:01,Waveform Type Sine Wave, Output Connections (1)*Hard Wire 3-wire (8)*(H N + G) IEC 320 C13(8),Bypass Built-in Bypass, Output Short Circuit Protection Yes,Parallel Redundancy (Option) 1 + 1, Nominal Input Voltage 230V,Input Power Factor>0.98,Input Frequency 40-70Hz,Input Connections Terminal Block, Protection Thermal Circuit Breaker (250VAC/20A), Input voltage range for main operations full load 160 - 285V, Input voltage range for mains operation half load 160-285V, High Voltage withstand Capability 420 VAC, Green Mode Range 210-250 VAC (230 V), Battery Type Mintenance - free sealed Lead-Acid battery with suspended, electrolyte. 12V 42 Ah SMF battery for 30 Min Battery Back up.
SITC of 2MP IR Indoor Dome Fixed Camera- 1/2.8"Progressive Scan CMOS, 1920 × 1080 at 25fps, 2.8 mm Fixed lens, Color: 0.01 Lux at F1.2, ICR, ONVIF, support H.265, H.264, MJPEG, DWDR, 3D Digital Noise Reduction, Tripple individually configurable stream, 12 VDC & PoE, IR range: 40m, IP67, IK10, Edge Anlalytics- Line crossing detection, intrusion detection, Motion detection, video tampering, UL, CE, FCC certified. (DS-2CD3121G0-I (2.8 mm) (Approved Makes: Hikvision/ Honeywell/ Bosch)
SITC of 2MP IR Bullet Fixed Camera -1/2.8"Progressive Scan CMOS, 1920 × 1080 at 25fps, 2.8 mm Fixed lens, 0.01 Lux at F1.2, 0 Lux with IR, ICR, ONVIF (PROFILE S), support H.265, H.264, MJPEG, DWDR, 3D Digital Noise Reduction, Three individually configurable stream, 12 VDC & PoE, IR range: 40m, IP67, Edge Anlalytics- Line crossing detection, Intrusion detection, Motion detection, Scene change detection, Video tampering, UL, CE, FCC certified. (DS-2CD3021G0-I (2.8 mm) (Approved Makes: Hikvision/ Honeywell/ Bosch)
SITC of 64 ch Network Video Recorder - Connect Up to 64 IP Cameras, Dual OS, Up to 12 Megapixels Resolution, Two independent HDMI outputs, one HDMI output of 4K resolution,1 VGA output with output upto 1920 × 1080, Support H.265, MJPEG, Supports N+1 hot spare system,Supports RAID0, RAID1, RAID5, RAID6 and RAID10 ,Supports HDD hot swap, Supports Dual Power-Redundant, Incoming Bandwidth 320 Mbps, 8 SATA Hard Disks, ANR Technology, 8 SATA interfaces for 8 HDDs and capacity of each HDD upto 6TB, 3 × USB at least 1 × USB with 3.0, Alarm I/O 16/4, RS-485, RS-232, 2 RJ-45 10 /100/1000 Mbps self-adaptive Ethernet interface, Multiple network monitoring: Web viewer, CE, FCC, UL certified. (DS-7764NI-I8) (Approved Makes: Hikvision/ Honeywell/ Bosch)
SITC OF 32" LCD 24X7 Surveillance Monitor
SITC of 16 port Unmanaged Network PoE Switch: 24 port PoE Switch with PoE standard of IEEE 802.3af , IEEE 802.3at, PoE port, Uplink ports (DS-3E0326P-E) (Approved Makes: Hikvision/ Honeywell/ Bosch)
SITC OF Cat-6 Cable: UTP CAT 6, 305 meters,Core diameter: 0.53mm,OFC,CM,white (Approved Makes: Hikvision/ Honeywell/ Bosch)
SITC of 6TB Surveillance Hard Disk (ST6000VX0023) (Approved Makes: Hikvision/ Honeywell/ Bosch)
19" 6U Rack for Switches complete as required
Camera installation and Connectivity.
In-ceiling speaker 6" ceiling loudspeaker. 6/3W @ 100V, 100-15,000Hz, 93dB 1W 1M. Dimensions (L x H): 188mm x 76mm, mounting hole 170mm diameter. White( Surface mount speakers to be provided if no provision for ceiling speakers) Make: Cloud UK, Alfatron, Biamp.
Media player, mixer amplifier with Bluetooth. Supplied with remote control. On board tuner and MP3 player. Inputs: Front panel mic. input with priority function, rear panel balanced mic. input with phantom power. Emergency input function. Dual RCA line inputs. Outputs: RCA aux out. 60W at 70/100V and 4-16 Ohms. 24V backup power input.Make:Biamp, Alfatron.
LCD portable projector, 5,000 lumens, WUXGA, 16,000:1 contrast ratio, Aspect Ratio:16:10, Lens (Throw Ratio)1.6x manual zoom (throw ratio: 1.09–1.77:1), manual focus F 1.60–2.12, f 15.30–24.64 mm, Make: Panasonic, Christe, Barco.
113" Diagonal, 16:10 Aspect Ratio, black border on all sides, matt white fabric, motorised with remote and heavy duty Motor. Make AV-craft, grandview.
Projector ceiling mount 1x2, adjustment option. Make TS, B-Tech, Eqv.
Cable Manager with Power socket and HDMI. Make Logic/ Legrand.
C–HM/HM/ETH–50 ( 50 feet) make Kramer / Extron.
Equipment Rack, with Hardware and lock. Make Valrack/ Custom / Eqv.
SITC of 50 LPH RO Water Purifier alng with RO-AUTO MAX 50 lph, hdrophenumatic tank-10 LPH, Faucet-1 nozzle, accessories- clip, inlet & outlet pipe etc.
Description of Work
Clearing grass and removal of the rubbish up to distance 50 m outside the periphery of the area
GRASS PLANNING: PROPER GRASS PLANNING (BERMUDA GRASS ) FORPITCH .WE PROVIDE THREE MONTH MAINTENANCE FOR GRASS DEVELOPMENT LIKE : PROPER CUTTING,WATERING,SPREADING OF FERTILIZERS ETC
Earth work in excavation over areas ( exceeding 30 cm in depth. 1.5 m in width as well es 10 sqm on plan) including disposal of excavated earth , lead upto 50 m and lift upto 1.5 m; disposed earth to be levelled and neatly dressed.
All kinds of soil
Ali kinds of soil
Excavating, supplying and filling of local earth (including royalty but excluding cairriage cost) by mechanical transport upto a lead of 3km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. If local earth is available at more than 3 km lead the actual lead must be approved by compitent authority. cairraiage of material will be paid seperately and calculated after deducting initial lead.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth: consolidating each deposited layer by ramming and watering lead
depth exceeding 1.5m apart
Supplying and Filling in plinth with local sand and under floors including, watering, ramming consolidating and dressing complete.
With Chlorpyriphos EC 20% with 1% concentration
Providing designation 100 A one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as per building specification and direction of E/l,
1:1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
1:2:4 (1 Cement: 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
Extra for Providing and mixing water proofing material in cement concrete work in the proportion recommended by the manufactures.
Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-incharge. (The panel shuttering work shall be paid for separately). (Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately)
All work upto plinth level : Concrete of M-25 grade with minimum cement content of 330 kg/cum
All work above Plinth level upto floor V Level : Concrete of M-25 grade with minimum cement content of 330 kg/cum
Walls columns, pillars, posts cind struts
Beams, planth beams, girders, bressumers, contilevers, Suspended floors lintels roofs and staircases including spiral staircases, shelves etc.
Proiding M-25 grade R.C.C. instead of M-20 grade R.C.C.
TMTC-500- 08 mm dia.
TMTC-500- 10 mm dia.
TMTC-500- 12 mm dia.
TMTC-500- 16 mm dia.
TMTC-500- 20 mm dia.
TMTC-500- 25 mm dia.
Foundations, footings, bases of columns etc. for mass concrete.
Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
Suspended floors, roots, landings, balcnies and access platform..
Lintels, beams, plinth bams, griders, bressumers and contilevers.
Columns,Pillars, Piers, Abutments, Posts and Struts
Edges of slabs and breaks in floors and walls :
Weather shade,Chajjas, corbels etc. including edges
Cement mortar 1 .:6 (1 cement: 6 coarse sand )
Cement mortar 1 .:6 (1 cement: 6 coarse sand ) : Extra tor Brick work in superstructure above plinth level upto floor V cum
Cement mortar 1:6 (1 cement: 6 coarse sand )
Cement mortar 1 : 4 (1 cement: 4 coarse sand )
Size of Tile 60x60 cm
Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (Thickness to be specified by the manufacture) of approved make in all colours, shades except burgundy , bottle green , black of any size as approved by Engineer-in-charge in skirting , risers of steps and dados over 12 mm thick bed of cement Motar 1:3(1 cement: 3 coarse sand ) and jointing with grey cement slurry @ 3.3 kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer) of ist quality conforming to IS : 15622 of approved make in colours such as white , Ivory , Grey , Fume Red , Brown , laid on 20 mm thick Cement motar 1:4 (1 cement: 4 coarse sand ) including pointing the joints with white cement and matching pigment etc., complete.
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete asper the architectural drawings with 18 mm thick stone slab over 20 mm (average)thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth.
Providing 250mm wide brick drain in cement mortar (1:6) with av. 150mm. Clear depth and 250mm apron including cost of E/W. involved with 75mm cement concrete
1:6(1 cement: 6 coarse sand)
15 mm cement plaster on rough side of single or half brick wall of mix : (1 : 4)
1:4(1 cement: 4 coarse sand)
15 mm cement plaster(1:3) with punning
Providing and applying white cement based putty of average thickness 2 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Two or more coats on new work
New work (Two or more coat applied @ 1.67 ltr/ 10 sqm over and including priming coat of exterior primer applied @2.20 kg/ 10 sqm)
Applying priming coat: With ready mixed zinc chromate yellow primer of approved brand and manufacture on steel galvanized iron/steel works
Painting with ready mixed paint of approved brand and manufacture in all shades to give an even shade: New steel work (two or more coats)
Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area upto 0.75 sqm.)
Three track three panels sliding window with fly proof SS wire mesh (Two nos. glazed & one no. wire mesh panels) made of (small series) frame 92 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area of window upto 1.75 sqm).
Fixed to steel windows by welding
Fixed to openings/ wooden frames with rawl plugs screws etc
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
Hot finished welded type tubes
With average thickness of 120 mm and minimum thickness at khurras point to be 65
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement:2 coarse sand:4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 mx1 mx400 micron, finished 12 mm cement plaster 1:3 (1 cement:3 coarse sand) and a coat of neat cement rounding the edges and making and finishing the outlet complete
With float glass panes of 5.50 mm thickness(weight not less than 12.50 kg/sqm)
Providing and fixing M.S.fan clamp type I or II of 16 mm dia.M.S. bar bent to shape with hooked ends in R.C.C slabs during laying including painting the exposed portion of loop,all as per standard design complete.
35 mm thick
Frame size 50 x 100 mm
Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
Single rubber stopper
Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes,channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, ( for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts,fasteners etc.).
Supply and fixing of Flashing /Ridge/ and gable flashing colour coated up to : Supply and fixing of Flashing /Ridge/ and gable flashing colour coated up to : 300mm - 500 mm girth.
Providing & Fixing GE plastic 600mm dia Turbo Vents of approved make and laying in position as per drawing or as directed by Engineer-in-charge
Providing & Fixing clear polycarbonate sheet 1000 mm wide & 1.5 mm thick of approved make and laying in position as per drawings matching profile with galvalium sheet or as directed by Engineer-in-charge
Supply and fixing of Colour coated gutters with gutter supports, sealnts
Supply and Fixing of down Color coated 0.5mm thk. Sheet take pipe, Pipe flashing band, M.S strip U-clamp with complete accessories in color coated sheet.
Providing and fixing soil, waste and vent pipes : Sand cast iron S&S pipe as per IS: 1729
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
150mm diameter S.W pipe
560 mm diameter C.I. over (heavy duty) the weight of the cover to be not less than 108 kg.
80 mm dia. Nominal bore
100 mm diameter Class I
Providing and laying factory made chamfered edge Cement Concrete paver blocks of required strength,thickness & size/shape, made by table vibratory method , to attain superior smooth finish using PU or equivalent moulds, laid in required Grey colour & pattern over 50mm thick compacted bed of coarse sand, compacting and proper embedding / laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with jamuna sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand in footpath, parks,lawns, drive ways or light traffic parking etc. all complete as per manufacturer’s specifications & direction of Engineer -in-Charge:
(a) 80 mm thick c.c. paver block of M-35 grade with approved colour design and pattern.
Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5
Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of Engineer-in-Charge.
DenseGradedBituminousMacadamGrading. II:--Providing and laying dense graded bituminousmacadamwith 100-120 TPHbatch type HMP producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous [email protected] byweightoftotalmix andfiller, transporting thehotmixtoworksite, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rollingwithsmoothwheeled,vibratory and tandem rollers to achieve the desired compactionasperMoRTHspecificationclauseNo. 507 complete in all respects.
Bituminous concrete Grading -II Providingand layingbituminousConcretewith higher capacity batchtypeHotMixPlant using crushed aggregates of specified grading [email protected]%ofmix and filler, transporting thehotmix toworksite, laying with a hydrostatic paver finisher with sensor control to the requiredgrade, level and alignment, rollingwithsmoothwheeled,vibratory and tandem rollers to achieve the desired compaction as per MORT&H specification clause No. 507 complete in all respect.
PrimeCoat:-Providingandapplyingprimercoat withbitumen emulsion onprepared surface of granularBase includingclearingof roadsurface andsprayingprimer at therateof 0.60kg/sqm using mechanical means
TackCoat :--Providing andapplying tack coat withbitumenemulsionusingemulsionpressure distributorat therateof0.20kgpersqmonthe prepared bituminous/granular surface cleaned with mechanical broom
Seal Coat :--Providing andapplying tack coat withbitumenemulsionusingemulsionpressure distributorat therateof0.20kgpersqmonthe prepared bituminous/granular surface cleaned with mechanical broom
Geo Textile to prevent ingress of soil
(i) Normal Stress Areas with a minimum thickness of 15mm ( within permissible limit ) of finished track surface.
(ii) High Stress Areas with a minimum thickness of 20mm (within permissible limit) of finished track surface.
(iii) High Stress Areas with a minimum thickness of 25mm (within permissible limit) of finished track surface.
(iv) IAAF approved line marking with class -2 field certification by IAAF / WA.
Water jump Socket with hurdle for steeple chase
Polevault boxes with cover
Take off board system for long jump and triple jump including wooden board
Hammer cum discuss throwing cage with all socket, pole, door and net
Discussnthrowing cage
short put ring
aluminium kerbing
conversion circle
Reducer for hammer cum discuss ring
Supply and Installation of Portable Aluminium Goal Post
Providing and laying of DWC - SN8 (IS:16098-II) pipes : 300 mm dia, Pipe in under ground system for provision in electrical line and sprinkler linesleeve purposes and drainage outlet complete in all respect as per direction of engineer in charge.
Testing for base surface level undulations by survey of the prepared bituminous surface within the acceptable tolerance level of Road work but beyond the acceptable tolerance of World Athletics Class-1 Certification. identification of high or low points under 4M and IM straightedge, AND rectification of the same by appropriate spot levelling method including but not limited to grinding, cutting, patch work, seal coat, etc. to achieve surface level gradients and evenness as per the requirements of World Athletics surface tolerance levels as per clause 3.1.3.2 of the World Athletics Track & Field Facilities Manual.
Excavation of top soil and add filling of good earth mixed with organic material incl. Compaction, slope upto 4 inch thickness.
Irrigation and maintenance of the grass for 6 month including watering, fertilizing and pesticide. (with exisitng equipments)
Anti termite treatment of lawn area through premise 30.50% I P. one liter premise diluted in 499 liters water and applying solution @ 1.00 litre solution per sqm lawn or bed area.(two application) i/c cost of chemical)and as per direction of officer-in-charge.and as per direction of officer-in-charge
Supplying and stacking 200mm thick layer of washed river sand as per FIFA specifications suitable for high performance Football outfield including mixing of organic inclusions such as coco peat, neem cake, etc. as per the design.
Providing and laying of 100mm dia perforated pvc sub soil drainage pipes 6 kg/cm2 pressure perforation at 50% area of pipe . Whole pipe covered with geotextile material of 140-180 gsm as per design and drawing. Incl. filling of 20-40mm size aggregate bed and wrapping of geo textile arround the pipe with all fitting for the pipe complete all as per direction of engineer-in-charge.
Mixing earth and sjudge or manure in porportion specified or directed.
Spreading of sludge,dumpmanureor/andgoodearth inrequired thickness (Cost of sludge,dumpmanureor/andgoodearth tobe paid separately).
New work (Two or more coats
Supply and installation of fully computerized, automatic and single key operation pop-up sprinkler system " for surfaces including all fittings and accessories, 110 mm dia HDPE Pipe, 50 HP motor (KIRLOSKER) automatic panel, hydrant etc., fulfilling irrigation norms
W.C. pan with ISI marked white solid plastic seat and lid
Single squatting plate with 5 litre P.V.C. automatic flushing cistern
White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar tap
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :
One urinal basin with 5 litre white P.V.C. automatic flushing cistern
Providing and fixing PVC waste pipe for sink or wash basin including PVC waste fittings complete.
40 mm dia
Providing and fixing 600 x 450 mm beveled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P brass screws and washers complete.
Rectangular shape 453x357 mm
Providing and fixing PTMT liquid soap container 109 mm wide,125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.
600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms.
Providing and fixing on wall face unplastidsed-PVC(working pressure 4 kgf per sqm) rain water pipes conforming to IS :4985 including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. (SW)
75 mm diameter
110 mm diameter
Providing and fixing on wall face unplasticised -PVC molded fittings/accessories for unplasticised-PVC rain water pipes conforming to (S:4985 including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for therma expansion.(SW)
Coupler
Shoe plain, 110mm shoe
Providing and fixing unplasticised -PVC pipe clip of approved design to unplasticised PVC rain water pipe by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing on cement mortar(1:4) 1 cement: 4corsa sand and making good the wall etc complete.(SW)
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
15 mm nominal outer dia Pipes
20 mm nominal outer dia Pipes
25 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. EXTERNAL WORK
40 mm nominal OD pipes
50 mm nominal outer dia Pipes
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
40 mm nominal bore
50 mm nominal bore
Up to 300 mm dia
15 mm nominal bore
20 mm nominal bore
15 mm nominal bore
15 mm nominal bore
15 mm nominal bore
25 mm nominal bore
150mm diameter
Providing and laying cement concrete 1:5:10( 1 cement: 5 coarse sand:10 graded stone aggregate 40mm nominal size) all-round S.W pipes including bed concrete as per standard design.
150mm diameter S.W pipe
Providing and fixing square-mouth S.W gully trap grade 'A' complete with C.I grating brick masonry chamber with water tight C.I cover with frame of 300x300mm size(inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:
With F.P.S bricks class designation 75
Providing and laying non-pressure NP2 class (light duty) R.CC pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2( 1 cement: 2 fine sand) including testing of joints etc. complete.
150mm dia R.C.C pipe
With F.P.S bricks class designation 75
constructing brick masnory road gully chamber
Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement: 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing and laying Non Pressure NP-4 class (Heavy duty) R.C.C.pi pes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete
450 mm dia RCC pipes.
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level.
300 mm dia
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools,plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level.
300 mm dia
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.
100 mm nominal size dia
150 mm nominal size dia
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.
100 mm nominal size dia
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.
Gravel packing in tubewell construction in accordance with IS: 4097,including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-incharge.
Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge.
200 mm dia
150 mm dia
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.
100 mm dia
150 mm clamp
Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I).
100 mm dia
150 mm dia
Constructing masonry Chamber 60x45x50 cm inside, in brick work in
18.37.1 With common burnt clay F.P.S.(non modular) bricks of class
Development of tube well in accordance with IS : 2800(part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully develo ped, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.
S/F/F 1 H.P. Cromption or any other apprioved make Motor and ISI make automatic starter mounted on a common wooden board etc. all complete job.
S/F/F 2 H.P. Cromption or any other apprioved make Motor and ISI make automatic starter mounted on a common wooden board etc. all complete job.
Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.
STEEL ALMIRAH WITH 4 SHELVES (L)900MM X (D)450MM X (H)1980MM. STOREWELL WITH 4 SHELVES GAUGE: BODY: 22 GAUGE *DOORS: 20 GAUGE, The Product Should be Certified Company BIFMA,JSO 50001, Green Guard/Green PRO, Sedex,AlOTA, IGBC, AGSI,FSC & PEFC
TABLE WITH SIDE TABLE :- Providing and fixing Table with side table : Table with side table : Table and side Table top made 36 mm thk PLPB Board with balancing laminate below the top. Under structure made of 36/ 25 mm thk BSL PLPB . Table having wooden keyboard and metal CPU Troley and one 2D + 1 F mobile pedestal.
High Back Chairs for cabins :-Proving and placing in position heigh back revolving chair of seat & back made up of hi- quility leatherite made up of 1.2+/-0.1cm thick hot press plywood measured. Chair upholstered with leatherite and moulded foam. The foam is desinged with contoured lumber support for extra confort. The armrest is made of black PP armrest. The front center tilt mechanism is designed with features like 360 degree revolving type, chair has lift mechanism for height adjustment resting on PP base dia 60-61 cm with surprior quality five castor wheel pronged with steel strip twin castor wheels and centre title mechanism etc. The product should be from BIFMA compliance and FSC certified company etc. complete as per the approved photograph and as per the direction of Engineer - in -Charge.
Reception Table -Size- 2400x750x950mm. Table top 25mm with 10mm glass which will stand on ss studs.table with both side 3 drawers. The Product Should be Certified Company BIFMA,Green Guard and as per direction of E/I
Mid Back Chair- (Back Height-495xBack Width-470)mm & (Seat Depth 485xSeat Width-475)mm witlh Min-Max Heloht (410-470)mm. Nylon hase chair with push back mechanism & Fix handle. Back & seat cover cushlon chair uphlostered in fabric & adjustable amrest locks any posltlon. Syncro mechenism with locking system and five star Nylon base with nylon casters. Seat & Back made up of 14mm thick boiling water proof plywood os ISI303. Chair rotates a full 360 degree in either direction for ease of motion. |Standard on every executive with task chair & controls rate and ease with which chair reclince t difforcnt welght and strengths of users. Quick and easy adjustment regulated height of chair rolativo to floor. Back reclines at A 2-t0-1 rotio to the seat. 5% post consumod rooycled cnlenl & 30% total recycled content. The Product Should be Certifled Company BIFMA,ISO 50001,Green Guard/Green PRO, Sedex, AIOTA, IGRC, AGSI,FSC & PEFC. Color-Black
3 seator/ chrome chair 3 sector chair (Chrome) Made of cushion with high density cold cured self skinned pre moulded foam of 50-60 density the shape plywood . Upholstery is done by using high - pressure pneumatic spray glue and pnematic press over come base & legs etc. The product should be BIFMA, ISO-19001,14001, OHSAS18001 , IGBC, FIRA Certified. as per the approved photograph and as per the direction of Engineer - in -Charge.
Providing and Supply Pitch Roller (Hand Roller, 1.5 tone)
Providing and Supply Grass Cutter (Honda, Petrol Lawn mover)
Group C
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc.as required.
Wiring for light/ power plug with 2x4 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit along with 1 No 4 sq.mm. FR PVC insulated copper conductor single core cable for loop earthing as required.
2x2.5 Sq.mm +1x2.5 Sq.mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
2 x 6 sq.mm + 1 x 6 sq.mm. earth wire
Supplying and fixing PVC/G.I box of 200mm x 250mm x 60mm deep on surface or in recess with suitable size of phenolic laminated sheet cover in fornt including painting etc as required.
Supplying and fixing suitable GI Box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin, 15/16 amps modular socket outlet and 15/16 amps modular switch, connection, painting etc. as required. (for power plug ).
Supplying and fixing suitable size G.I Box with modular plate and cover in front on surface in recess including providing and fixing 3 pin, 5/6 amps modular socket outlet and 5/6 amps modular type switch, connection, painting etc., as required. (for light plugs to be used in non residential buildings ).
4 way ( 4 + 12 ), Double door, horizontal type
6/32 amp single pole
40 A to 63 A, TP&N
6 A to 32 A, SP&N
25/100 Amp, 10 KA
400 A, 50 KA, FPMCCB
Providing and fixing following capacity four pole ON-load/ panel mounted changeover switches inside the existing cubical panel board including drilling holes in cubicle panel, making connections etc. as required.
Supply and fixing of fabricated Electrical control panel of cubical construction, floor/wall mounted type, fabricated out of 16 SWG CRCA sheet, compartmentalised with hinged doors, dust and vermin proof, powder coated painting of approved shade after 7 tank treatment process, cable alley, internal wiring, earth terminals, Bus bar Chamber, insulator and complete in all respect etc and panel manufactures must be approved by CPRI. (But without RYB inicator, ammeter, voltmeter, inter-connection copper conductor cable/solid copper strip, switchgears etc.)
Supply and fixing panel mounted digital multimeter (Voltmeter & ammeter) including CT coil and RYB pilot indictor in the existing cubical panel board including drilling holes in the panel board making connections etc as required.
Supply and installation of regular/standard model A.C. ceiling fan of 1200 mm sweep with service value (CM/MM) minimum 4.00, Air delivery minimum 210 cum/min including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated copper conductor etc as required.
Supply and Installation of 300 mm 230volt AC exhaust fan in the existing opening including making good the damage connection testing commissioning etc as required.
12 watt LED lamp
Supplying and fixing recess/surface mounted 23/24 (1ft X 1ft) watt LED downlighter complete with integrated electronic driver & LED directly on ceiling/false ceiling including connection with 1.5 sq.mm FR PVC insulated copper conductor cable and earthing the body etc. as required.
300 sq. mm, 3.5 core
95 sq. mm, 3.5 core
Providing chemical/mineral maintenance free earthing system comprising of copper coated earth electrode 3 metre length and 17.2 mm outer dia along with 25 kg earth conductivity enhancing back fill mineral compound for earth electrode to fill up the excavated earth and earth inspection pit etc. as required.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
SITC of high-quality integrated LED Flood Light with a minimum system lumen of 70K Lm and system wattage not exceeding 500W(+5%) with a minimum efficiency 140 lumen/watt. CCT of 5700K with SDCM of < 5 and CRI : 70. The housing should be of non-corrosive high-pressure die-cast aluminum to with stand extreme environments. It should have corrosion resistant powder coating to pass NSS of 500 Hrs. with PF > 0.95. Lifetime of 75K hours @L70. Product should be suitable for continuous operation (10-12 Hrs. per day). The Ingress protection should be minimum IP 66 with an IK rating of 08. Optical and control gear compartments shall be maintainable/replaceable without impacting the LED units. The access to the optical and the gear compartment should be separate. While accessing the gear compartment, the optical compartment should not be accessible. The Luminaire should have a 20 KV /10 KA SPD duly bolted in the Luminaire. The SPD should be able to sustain a minimum 15 hits of 10KA rating i.e. Total of 45 hits across all the three modes as per IEEE 62.41.2. The Luminaire should have a breather to ensure that air balance inside and outside of the Compartment .The luminaire should be of Class B Serviceability. The wattage of each LED should be greater than 1 watt and less than 3 Watt. Only high power Single white LED chip with ceramic based suitable for outdoor use is allowed. Multi Chip, array multi die, mid power, Integrated arrays and COB’s are not permitted. The High power LED used in the luminaire shall be SMD type only of make LGIT, Lumileds, Osram, Nichia, and CREE & no other make. The luminaire should be capable of withstanding voltage stress of 440V for 8 Hrs., should have an auto shutdown @ 325V and have an auto recovery feature. The Drivers should be a potted driver not a printed circuit board without casing, mounted inside the luminaire. The luminaires should have a breather ensuring a stable optical and thermal management. The weight of the luminaire should not be more than 12 Kg.
SITC of high-quality integrated LED Flood Light with a minimum system lumen of 74K Lm and system wattage not exceeding 500W(+5%) with a minimum efficiency 145 lumen/watt. CCT of 5700K with SDCM of < 5 and CRI : 70. The housing should be of non-corrosive high-pressure die-cast aluminium to with stand extreme environments. It should have corrosion resistant powder coating to pass NSS of 500 Hrs. with PF > 0.95. Lifetime of 75K hours @L70. Product should be suitable for continuous operation (10-12 Hrs. per day). The Ingress protection should be minimum IP 66 with an IK rating of 08. Optical and control gear compartments shall be maintainable/replaceable without impacting the LED units. The access to the optical and the gear compartment should be separate. While accessing the gear compartment, the optical compartment should not be accessible. The Luminaire should have a 20 KV /10 KA SPD duly bolted in the Luminaire. The SPD should be able to sustain a minimum 15 hits of 10KA rating i.e. Total of 45 hits across all the three modes as per IEEE 62.41.2. The Luminaire should have a breather to ensure that air balance inside and outside of the Compartment .The luminaire should be of Class B Serviceability. The wattage of each LED should be greater than 1 watt and less than 3 Watt. Only high power Single white LED chip with ceramic based suitable for outdoor use is allowed. Multi Chip, array multi die, mid power, Integrated arrays and COB’s are not permitted. The High power LED used in the luminaire shall be SMD type only of make LGIT, Lumileds, Osram, Nichia, and CREE & no other make. The luminaire should be capable of withstanding voltage stress of 440V for 8 Hrs., should have an auto shutdown @ 325V and have an auto recovery feature. The Drivers should be a potted driver not a printed circuit board without casing, mounted inside the luminaire. The luminaires should have a breather ensuring a stable optical and thermal management. The weight of the luminaire should not be more than 12 Kg.
Supply, Programming and Commissioning of Outdoor type external lighting CCMS Feeder Panel for Remote Management, Switching, Multistep Dimming and Monitoring of Streetlights using group control system to be supplied considering 1 feeder Pillar cabinet for 10KW LED Load, Central Dimming required from group controls. The dim level commands to the luminaires shall be generated from the LMS equipment installed in the electrical cabinet without any additional wires or pilot lines & minimum 8 dynamic steps should be there excluding ON & OFF. All the luminaires in the segment shall have the same dim level as per the command from the LMS or local trigger. Dimming commands from the mains power cabinet shall not be interrupted by any intermediary luminaire failures between poles. Luminaires shall fall back to 100% light output if there any interruption in dimming commands. Lighting cabinets/feeder pillar to be connected independently to lighting management system cloud server through GPRS/Ethernet with open internet must have following features: a) Automatic (with a timer), remote (with GPRS/GSM) and manual switching option b) Remote energy measurement c) Near real time monitoring d) Alarms and report generation e) Emergency override locally and remotely f) Web based user interface with integrated visual maps g) Data security and secured system access h) Prevent unauthorised physical access to the street light control box i) secured 128 Bit encrypted communication between server and street light feeder panel.
Erection, Testing & Commissioning of the 16m Sports Highmast Pole with Ladder Supply of foundation bolts manufactured from special steel along with nuts, washers, anchor plate and common templateHigh mast with the help of suitable tools and plants, wiring of luminaires with all wiring materials like PVC insulated PVC sheathed flexible cable of suitable copper conductor cores of 2.5 sq. mm, lugs and all labour.
SITC of Total 48 KW HYBRID SOLAR SYSTEM(or as per Requirement of Backup Time) WITH 5 HOURS BACK Up with Inverter (48KW HYBRIDE INVERTER (WARRANTY 5 YEARS),.LITHIUM BATTRY 200 AH Capacity 5 YEARS WARRANTY. CYCLE 3000 TIMES),Structure(STRUCHER 5 FEET./3 FEET GI STUCHER),Nut Bolts etc ( ALL WIRING. DC DVR. AC DVR.COMPLETE WIRING WITH ALL APPLIANCE included)
Supplying and fixing following types LED Flood light with minimum efficacy 100 lm/w in die cast aluminium housing, toughened glass, IP 66 protection and complete with electronic driver etc on pole/building including connection earthing the body etc as required.
SITC of mounting Channel in which LED flood light can mount for illumination of court.Mounting Stracture should have Proper provision of light holding.
Supply and fixing of TLL 50WATT all in one street light along with MONo Crystalline 50 Wp solar panel and 308 wh Lithium battery aluminium housing , LED rating -50000Hr@LM70, Efficacy Lumen /watt> 130,CRI->70, charge controller. Type MPPT, SENSOR Type -PIR Dusk to down Operation,TLL-jupitor-AIO50
Single arm 1500 mm
315 KVA, Copper wound, Energy Efficiency Level-2
CCTV Network Camera Bullet 4 MP (Brand - Hikvision / Bosch / Honeywell) Image Sensor - 1/3" Progressive Scan CMOS, Shutter Speed - 1/3s to 1/10,000 s, Lens - 2.7mm, 4mm, 6mm @ F2.0angle of view: 106°(2.7mm), 83°(4mm), 55.4°(6mm), Day &Night - IR cut filter with auto switch, White Balance - Automatic/Manual, Video Compression - 4/MJPEG/H.264+, Max. Resolution - 2688×1520, Communication Interface - 1 RJ45 10M/100M Ethernet port, Base T
CCTV Network Camera Dome 4 MP Image Sensor - 1/3" Progressive Scan CMOS, Shutter Speed - 1/3s to 1/10,000 s, Lens - 2.7mm, 4mm, 6mm @ F2.0angle of view: 106°(2.7mm), 83°(4mm), 55.4°(6mm), Day &Night - IR cut filter with auto switch, White Balance - Automatic/Manual, Video Compression - H.264/MJPEG/H.264+, Max. Resolution - 2688×1520, Communication Interface - 1 RJ45 10M/100M Ethernet port, Base T
Supply / Installation and Commissioning of 24 Port Network Switch GIGA PoE,IEEE 802.3at and IEEE 802.3af Power over Ethernet (PoE) compliant,24x10/100/1000 Mbps Auto-MDIX PoE ports,Provides up to 30 watts per PoE port,PoE power budget 370W,4 KV surge protection for PoE ports,IEEE 802.3x flow control support,Plug-and-play installation,8.8 Gbps switching fabric,2.75 Mbits RAM Data Buffer,4K MAC address entries,Sturdy metal enclosure
1 run of cable
Hard disk 6 TB
12U Network Rack
Display : Screen size – 42 inch or above (LG/Sony/ Samsung/ Philips), Panel Technology IPS, Surveillance Monitor
32 bit microprocessor based Intelligent Addressable Fire Alarm Control panel with 4 loops with battery back up. The panel would be modular, decentralized, with The panel shall be consisting with minimum 240 character LCD display and for networking. The Panel would be able to record atleast 60,000 events history. Each loop would be capable to have atleast 250 addressable detectors and addressable devices with up to 3.5km loop length. Make: Schrack Seconet (Vds approved)
1 KVA LINE INTERACTIVE UPS WITH 30 MIN BATTERY BACK UP
Supplying and fixing Intelligent Addressable type multicriteria detector with base for use as heat or smoke or combined both with automatic electronic addressing, microprocessor type with builtin integrated short circuit isolator including testing, commissiong etc as reqd.
Supplying and fixing Intelligent Addressable type Heat detector with base with automatic electronic addressing, microprocessor type with builtin integrated short circuit isolator including testing, commissiong etc as reqd.
Sypplying and fixing Intelligent Addressable Manual Call Point having inbuilt short circuit isolator i/c testing and commissiong etc as reqd.
Addressable sounder with interface module, power supply for suonder and programmable by software having integrated short circuit isolator & having operating temperature -10⁰C to + 55⁰C
Analogue Addressable Control module with IP66 casing containing four relay outputs, each containing a potential-free DPDT contact with a fail-safe and in-built short circuit isolator The ambient temperature range shall be -20C to +60C.
Duel LED Response Indicator (LOCAL)
Supplying and laying of 2x1.5 sq.mm. ISI marked copper armourd conductor cable with gland scoket and other wiring accessories on the existing surface/tray/shaft etc as reqd
Quantity :
Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring,earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required :
25 mm dia
80 mm dia
150 mm dia
Single headed stainless steel
150 mm dia
80 mm dia
150 mm dia
Stainless steel (Grade 304)
Stainless steel (Grade 304)
2 way-100 mm dia M.S. Pipe
Supply and fixing air vessel made of 250 mm dia 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement of 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthatic enamal paint approved shade as required.
Providing and fixing following size Pressure gauge (0-15 Kg/Cm2) complete with shut off valve duly calibrated before installation complete as required & as per enclosed specification. 150mm dia.
Description of Work
12.5 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, made of Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16mm thick fire retardant PVC film on the face side and 12micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around
Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade:
A=n*2*(L+B)*H
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:
Providing & Laying 2.0 mm thick Vinyl Flooring ( Armstrong / Wonderfloor, etc )
DGM BSBCCL Bhagalpur
DESCRIPTION
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit, with modular type switch, modular plate, suitable size G.I. box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc.as required
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc.as required.
Wiring for twin control light point with 1.5 sq. mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box etc as required
Wiring for light/ power plug with 2x4 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit along with 1 No 4 sq.mm. FR PVC insulated copper conductor single core cable for loop earthing as required.
Metre
Metre
Metre
Metre
Metre
Supplying and fixing PVC/G.I box of 200mm x 250mm x 60mm deep on surface or in recess with suitable size of phenolic laminated sheet cover in fornt including painting etc as required (Adopter box above each D.B).
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps "C" curve, SP MCB, in sheet steel Enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and ommissioning etc. as required.
Supplying and fixing suitable size G.I Box with modular plate and cover in front on surface in recess including providing and fixing 3 pin, 5/6 amps modular socket outlet and 5/6 amps modular type switch, connection, painting etc., as required. (for light plugs to be used in non residential buildings )
Supplying and fixing 12 modules GI box along with moduler base & cover plate surface or in recess including providing and fixing of 4 nos 6 pin 15/16 amps socket outlet with 4 no 15/16A moduler type switch ,connection etc. as required.
Main Bus Bar: 4 strip 300 amp bus bar made of electrical grade copper strip enclosed in separate bus bar chamber, provided with DMC/ SMC bus bar support duly insulated with heat shrinkable sleeves in distinct colours as reqd: 1 set (1 Amp per sqmm.)
Providing and fixing MV danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Providing chemical/mineral maintenance free earthing system comprising of copper coated earth electrode 3 metre length and 17.2 mm outer dia along with 25 kg earth conductivity enhancing back fill mineral compound for earth electrode to fill up the excavated earth and earth inspection pit etc. as required.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required
Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required
P/F 4.00 mm dia.copper wire on surface or in recess for loop earthing along with existing surface /recess for loop earthing along with existing surface/recessed conduit /submain wiring/cable etc required.
Metre
Supply and fixing 100 mm dia medium class GI pipe etc as required.
Supply and Installation of regular/standard module AC ceiling fan of 1400 mm sweep including wiring the down rod of standard length 9 upto 30 cm ) with 1.5 sq mm FR pvc insulated copper conductor etc as required.
Supply and Installation of 300 mm 230volt AC exhaust fan in the existing opening including making good the damage connection testing commissioning etc as required.
Supply and installation of 600 mm, 230 V A.C. wall mounted Air circulator, heavy duty fan including fixing the bracket, making onnection, testing, commissioning etc as required.
Supplying and fixing indoor recess mounting 36 watt LED flat panel luminaire suitable for armstrong/grid ceiling and complete with electronic driver etc. directly on false ceiling including connection with 1.5 sqmm fR PVC insulated copper conductor cable and earthing the body etc as required.
Supplying and fixing 90 watt LED type FLOOD light with die cast aluminium housing for ingress protection of IP65 and complete with all accessories etc and connection with FR PVC insulated copper conductor cable and earthing the body etc. as required
Meter
Meter
Supply and fixing of fire extinguisher, ABC Type 4.00kg. Capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.
Supply and fixing of shock treatment chart (prescribed under I. E. rules) duly framed with glass and supported from back with hard board or soft board with supply of all material, labour, T&P for proper completion of work.
Supply and fixing of fire bucket, round bottom made of GI sheet 9-11 litres capacity duly painted as per fire brigade design, supported on hanging bracket chained and locked, initially filled with fine river sand, water as per direction of Engineer-in-Charge.
SITC AC split(1.5 ton) with stabilizer ISI standard as per specification 5 star inverter AC.. ( Make- blue star/mitsubishi/lg/carrier/Hitachi)
Supplying and fixing modular type 25 amps A.C. unit box with ON/OFF MCB on surface or in recess complete with connections, testing and commissioning etc as required.
Extra copper piping electrical wire for split AC
Supplying and drawing of UTP 4 pair CAT-6 LAN cable in the existing surface/recessed steel /PVC concuitas required.
Category 6 UTP Patch Cords - 1 Mtr Standard Colour - Blue, Grey, Yellow, RJ45 Plug - Polycarbonate plug, Current Rating - 1.5A max, Insulation Resistance - 500MΩ/km(min)@500 Vdc, Contact Resistance - 15 mΩ (max) per contact
Category 6 UTP Patch Cords - 2 Mtr Standard Colour - Blue, Grey, Yellow, RJ45 Plug - Polycarbonate plug, Current Rating - 1.5A max, Insulation Resistance - 500MΩ/km(min)@500 Vdc, Contact Resistance - 15 mΩ (max) per contact
24-port GbE Smart Managed Switch with GbE Uplink Interfaces-24 Ports 10/100/1000Mbps+4 SFP;Port Standards & Functions-IEEE 802.3 10BASE-T Ethernet (twisted-pair copper),IEEE 802.3u 100BASE-TX Fast Ethernet (twisted-pair copper),IEEE 802.3ab 1000BASE-T Gigabit Ethernet (twisted- pair copper),IEEE 802.3az compliance Auto-negotiation,IEEE 802.3x Flow Control; Full/Half Duplex-Full/half duplex for 10/100 Mbps speeds,Full duplex for Gigabit speed;Media Interface Exchange Auto MDI/MDIX adjustment for all twisted-pair ports;Switching Capacity 56 Gbps; Transmission Method Store-and-forward; MAC Address Table 16,000 entries per device, Maximum 64 bytes packet forwarding rate 41.7 Mpps,Packet Buffer Memory 1.5 MB,Maximum Power Consumption 22.45 watts, Standby Power Consumption 17.84 W/240 V, Acoustics 0 dBA Heat Dissipation 76.55 Btu/hr, Operating Temperature -5 to 50 ˚C (23 to 122 °F), Storage Temperature -20 to 70 ˚C (-4 to 158 °F), Operating Humidity 0% to 95% non-condensing, Storage Humidity 0% to 95% non-condensing, Diagnostic LEDs Link/Activity/Speed (Per 10/100/1000 Mbps port), Certifications CE (LVD) BSMICCC, C-Tick. Netgear / D-link/ Cisco.
Category 6, UTP 24-Port Patch Panel Size - 482.6mm x 44.2 (19’’ x 1U), Panel Material - Steel-fully powder coated, Unshielded - RJ 45, Plug Insertion Cycle - 750 times DC Resistance- 72Ω max, Voltage Rating - 72 Vdc max, Current Rating - 1.5A max
Supply fitting fixing Rack 19" 12U fully powder coated complete etc as required with complete accessories (5 amp x 6 socket, wire manager, rack fan) VALRACK/ Netrack make.
Supplying and fixing of RJ 45 computer socket suitable for Cat 6 on module GI box along with base & cover plate in surface or in recess including making connection, soldering etc. as required.
Smart-UPS On-Line, 30 kW /30 kVA with 30 minutes Backup 12 V 42 AH SMF Battery UPS Toplogy Double Conversion On-Line, Power Rating (VA / Watts) 30000Watts/30000VA, Form Factor Rack/Tower Convertible; Output Power Capacity 30000 Watts/30000 VA, Max Configurable Power 30000Watts/30000VA, Nominal Output Voltage 230V, Output Voltage Note Configurable for 220 : 230 or 240 nominal output voltage, Efficiency at Full Load 94.00%, Output Voltage Distortion Less than 3%,Output Frequency (sync to mains) 50/60 Hz +/- 3 Hz,Crest Factor 03:01,Waveform Type Sine Wave, Output Connections (1)*Hard Wire 3-wire (8)*(H N + G) IEC 320 C13(8),Bypass Built-in Bypass, Output Short Circuit Protection Yes,Parallel Redundancy (Option) 1 + 1, Nominal Input Voltage 230V,Input Power Factor>0.98,Input Frequency 40-70Hz,Input Connections Terminal Block, Protection Thermal Circuit Breaker (250VAC/20A), Input voltage range for main operations full load 160 - 285V, Input voltage range for mains operation half load 160-285V, High Voltage withstand Capability 420 VAC, Green Mode Range 210-250 VAC (230 V), Battery Type Mintenance - free sealed Lead-Acid battery with suspended, electrolyte. 12V 42 Ah SMF battery for 30 Min Battery Back up.
SITC of 2MP IR Indoor Dome Fixed Camera- 1/2.8"Progressive Scan CMOS, 1920 × 1080 at 25fps, 2.8 mm Fixed lens, Color: 0.01 Lux at F1.2, ICR, ONVIF, support H.265, H.264, MJPEG, DWDR, 3D Digital Noise Reduction, Tripple individually configurable stream, 12 VDC & PoE, IR range: 40m, IP67, IK10, Edge Anlalytics- Line crossing detection, intrusion detection, Motion detection, video tampering, UL, CE, FCC certified. (DS-2CD3121G0-I (2.8 mm) (Approved Makes: Hikvision/ Honeywell/ Bosch)
SITC of 2MP IR Bullet Fixed Camera -1/2.8"Progressive Scan CMOS, 1920 × 1080 at 25fps, 2.8 mm Fixed lens, 0.01 Lux at F1.2, 0 Lux with IR, ICR, ONVIF (PROFILE S), support H.265, H.264, MJPEG, DWDR, 3D Digital Noise Reduction, Three individually configurable stream, 12 VDC & PoE, IR range: 40m, IP67, Edge Anlalytics- Line crossing detection, Intrusion detection, Motion detection, Scene change detection, Video tampering, UL, CE, FCC certified. (DS-2CD3021G0-I (2.8 mm) (Approved Makes: Hikvision/ Honeywell/ Bosch)
SITC of 64 ch Network Video Recorder - Connect Up to 64 IP Cameras, Dual OS, Up to 12 Megapixels Resolution, Two independent HDMI outputs, one HDMI output of 4K resolution,1 VGA output with output upto 1920 × 1080, Support H.265, MJPEG, Supports N+1 hot spare system,Supports RAID0, RAID1, RAID5, RAID6 and RAID10 ,Supports HDD hot swap, Supports Dual Power-Redundant, Incoming Bandwidth 320 Mbps, 8 SATA Hard Disks, ANR Technology, 8 SATA interfaces for 8 HDDs and capacity of each HDD upto 6TB, 3 × USB at least 1 × USB with 3.0, Alarm I/O 16/4, RS-485, RS-232, 2 RJ-45 10 /100/1000 Mbps self-adaptive Ethernet interface, Multiple network monitoring: Web viewer, CE, FCC, UL certified. (DS-7764NI-I8) (Approved Makes: Hikvision/ Honeywell/ Bosch)
SITC OF 32" LCD 24X7 Surveillance Monitor
SITC of 16 port Unmanaged Network PoE Switch: 24 port PoE Switch with PoE standard of IEEE 802.3af , IEEE 802.3at, PoE port, Uplink ports (DS-3E0326P-E) (Approved Makes: Hikvision/ Honeywell/ Bosch)
SITC OF Cat-6 Cable: UTP CAT 6, 305 meters,Core diameter: 0.53mm,OFC,CM,white (Approved Makes: Hikvision/ Honeywell/ Bosch)
SITC of 6TB Surveillance Hard Disk (ST6000VX0023) (Approved Makes: Hikvision/ Honeywell/ Bosch)
19" 6U Rack for Switches complete as required
Camera installation and Connectivity.
In-ceiling speaker 6" ceiling loudspeaker. 6/3W @ 100V, 100-15,000Hz, 93dB 1W 1M. Dimensions (L x H): 188mm x 76mm, mounting hole 170mm diameter. White( Surface mount speakers to be provided if no provision for ceiling speakers) Make: Cloud UK, Alfatron, Biamp.
Media player, mixer amplifier with Bluetooth. Supplied with remote control. On board tuner and MP3 player. Inputs: Front panel mic. input with priority function, rear panel balanced mic. input with phantom power. Emergency input function. Dual RCA line inputs. Outputs: RCA aux out. 60W at 70/100V and 4-16 Ohms. 24V backup power input.Make:Biamp, Alfatron.
LCD portable projector, 5,000 lumens, WUXGA, 16,000:1 contrast ratio, Aspect Ratio:16:10, Lens (Throw Ratio)1.6x manual zoom (throw ratio: 1.09–1.77:1), manual focus F 1.60–2.12, f 15.30–24.64 mm, Make: Panasonic, Christe, Barco.
113" Diagonal, 16:10 Aspect Ratio, black border on all sides, matt white fabric, motorised with remote and heavy duty Motor. Make AV-craft, grandview.
Projector ceiling mount 1x2, adjustment option. Make TS, B-Tech, Eqv.
Cable Manager with Power socket and HDMI. Make Logic/ Legrand.
C–HM/HM/ETH–50 ( 50 feet) make Kramer / Extron.
Equipment Rack, with Hardware and lock. Make Valrack/ Custom / Eqv.
SITC of 50 LPH RO Water Purifier alng with RO-AUTO MAX 50 lph, hdrophenumatic tank-10 LPH, Faucet-1 nozzle, accessories- clip, inlet & outlet pipe etc.
Description of Work
Earth work in excavation over areas ( exceeding 30 cm in depth. 1.5 m in width as well es 10 sqm on plan) including disposal of excavated earth , lead upto 50 m and lift upto 1.5 m; disposed earth to be levelled and neatly dressed.
Extra for every additional lift of 1.5 m or part thereof in :
Closed timbering over Area
Supplying and Filling in plinth with local sand and under floors including, watering, ramming consolidating and dressing complete.
Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling and plugging 12 mm diameter holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floor.
Providing designation 100 A one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as per building specification and direction of E/l,
Providing and laying in position cement concrete of specified grade.
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana /Ordinary Portland /Portland Slag cement
All work above Plinth level upto floor V Level : Concrete of M-25 grade with minimum cement content of 330 kg/cum
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete.
TMTC-500- 08 mm dia.
TMTC-500- 10 mm dia.
TMTC-500- 12 mm dia.
TMTC-500- 16 mm dia.
TMTC-500- 20 mm dia.
Centring and shuttering including strutting, propping etc. and removal
Foundations, footings, bases of columns etc. for mass concrete.
Suspended floors, roots, landings, balcnies and access platform..
Lintels, beams, plinth bams, griders, bressumers and contilevers.
Columns,Pillars, Piers, Abutments, Posts and Struts
Weather shade,Chajjas, corbels etc. including edges
Brick work with fly ash bricks as per IS 12894(2002) & IS 3495 in foundations and plinth in :
Brick work with fly ash bricks as per IS 12894(2002) & IS 3495 in foundations and plinth in
Brick work with bricks of class designation 100A in foundations and plinth in :
Half brick masonry with bricks of class designation 100A
Kota stone slab flooring over 20 mm (average ) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete . Base with 1:1:1 (1 lime : 1 surkhi: 1 coarse sand ) / 1:4 (1 cement: 4 coarse sand )
Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer) of ist quality conforming to IS : 15622 of approved make in colours such as white , Ivory , Grey , Fume Red , Brown , laid on 20 mm thick Cement motar 1:4 (1 cement: 4 coarse sand ) including pointing the joints with white cement and matching pigment etc., complete.
Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth.
12 mm cement plaster on rough side of single or half brick wall of mix : (1 : 6)
15 mm cement plaster on rough side of single or half brick wall of mix : (1 : 6)
15 mm cement plaster(1:3) with punning
Providing and applying white cement based putty of average thickness 2 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade:
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:
Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile),...
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required...
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge.
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
Supplying and fixing-rolling shuters of approved make.made of required size of M.S.Iaths interlocked together through their intire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arragements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.
Providing and fixing ball bearing for rolling shutters
Extra for providing mechanical device chain and crank operation for operating rolling shutters:
Detailing,Engineering,Manufacturing,Painting,Supply,transportation & Erection of steel structure system for PEB structure with Z purlin , sagrods runners , cross bracing clip fastners using 350 MFa grade Hitensible steel. All fabrication work shall be done off-shore (not on site) bolt in connection type and only site assembly shall be done with the help of high strength bolts (HSFG) . All testing and inspection facility shall be in-house to ensure 100% checking and inspection prior to shipment from the fabrication shop. All structure steel shall be min 350 Mpa yield strength of E350 grade or equivalent grade but not less than 350 Mpa as per approval of Engineer in-charge. All anchor bolts shall be high strength HSFG bolts for assembly and electro-galvanized of min. 8.8 grade. Entire steel structure shall be surface finished shot blasted as per SA 2 1/2 followed by applying 2 coat of epoxy base primer each coat of min. 35 micron and 2 coat of final finish epoxy paint shall be applied each of min. 35 micron thickness on entire structure prior to shipment. Final painting can be done at site during installation.All design & drawings shall be per-approved by Engineer in-charge
Supply & fixing of Hi-Rib profiled sheeting 1000-1030 cover width, 28/30 mm crests @ 250-255 mm c/c manufactured out of 0.55 mm TCT hi-tensile Multi Cloured Galvalume steel (AZ-150 gsm. Aluminium-Zinc alloy metallic coating of total both sides 550 Mpa yield stress as per AS-1397). The sheet shall have wide pans with 3 small stiffening ribs for effective water shedding and special male/female ends with full return legs on side laps for purlin support. The male end of the sheet shall have anti-capillary flute at side lap to prevent leakages. The sheet shall be passivated and clear resin coated. The sheet shall be fixed by means of galvanised self-drilling self tapping fasteners ( 12-14x55 with EPDM seals). The sheet shall be supplied in lengths maximum upto 6-12 Mtrs long to suit site dimensions
Supply and fixing of Multi Coloured galvalume sheet with screws on cladding.
Supply and fixing of Flashing /Ridge/ and gable flashing colour coated up to : Supply and fixing of Flashing /Ridge/ and gable flashing colour coated up to : 300mm - 500 mm girth.
Providing & Fixing GE plastic 600mm dia Turbo Vents of approved make and laying in position as per drawing or as directed by Engineer-in-charge
Providing & Fixing clear polycarbonate sheet 1000 mm wide & 1.5 mm thick of approved make and laying in position as per drawings matching profile with galvalium sheet or as directed by Engineer-in-charge
Supply and fixing of Colour coated gutters with gutter supports, sealnts
Providing & Fixging MS rain water pipe 100 x 125 mm of approved make in position as per drawings or as directed by Engineer-in-Charge.
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T"...
Providing & Laying 2.0 mm thick Vinyl Flooring ( Armstrong / Wonderfloor, etc )
Providing and fixing soil, waste and vent pipes : Sand cast iron S&S pipe as per IS: 1729
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.
Providing & Grouting of dowel tubes / Shear keys / Joints of precast members with M-60 grade cementitious grout (Non Shrink) of approved make by suitable means ( Free flowing /pump),curing etc. Complete as per directions of Engineer- in-charge. (The payment shall be made on the basis of actual weight of approved grout injected.)
Carriage of materials
Extra Cost of Materials
Providing and fixing water closet squatting pan (Indian type W.C.pan ) with 100 mm sand cast Iron P or S trap, 10 litre low fixtures complete, including cutting and making good the walls andlevel white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS :7231, with all fittings and floors wherever required :
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :
Providing and fixing wash basin with C.I brackets, 15mm C.P brass pillar taps, 32mm C.P brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :
Providing and fixing PVC waste pipe for sink or wash basin including PVC waste fittings complete.
Providing and fixing 600 x 450 mm beveled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P brass screws and washers complete.
Providing and fixing PTMT liquid soap container 109 mm wide,125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.
Providing and fixing on wall face unplastidsed-PVC(working pressure 4 kgf per sqm) rain water pipes conforming to IS :4985 including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. (SW)
Meter
Meter
Providing and fixing on wall face unplasticised -PVC molded fittings/accessories for unplasticised-PVC rain water pipes conforming to (S:4985 including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for therma expansion.(SW)
Providing and fixing unplasticised -PVC pipe clip of approved design to unplasticised PVC rain water pipe by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing on cement mortar(1:4) 1 cement: 4corsa sand and making good the wall etc complete.(SW)
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
metre
metre
metre
Providing and laying flanged C.I. standard specials such as tees,bends, collars, tapers, caps etc., suitable for flanged jointing as per IS : 1538 :
quintal
Providing and fixing brass stop cock of approved quality:
Providing and fixing C.P brass bib cock of approved quality conforming to IS:8931
Providing and fixing C.P brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.
Providing and fixing C.P brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931
Providing and fixing gun metal non- return valve of approved quality (screwed end)
Constructing brick masonry manhole in cement mortar 1:4(1 cement: 4 coarse sand) R.C.C top slab with 1:2:4 mix (1 cement:2 coarse sand: 4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement: 4 coarse sand:8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3( 1 cement: 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement: 2 coarse sand:4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design:
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools,plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level.
metre
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.
metre
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.
Gravel packing in tubewell construction in accordance with IS: 4097,including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-incharge.
Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge.
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.
Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I).
Constructing masonry Chamber 60x45x50 cm inside, in brick work in
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit, with modular type switch, modular plate, suitable size G.I. box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc.as required
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc.as required.
Wiring for twin control light point with 1.5 sq. mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box etc as required
Wiring for light/ power plug with 2x4 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit along with 1 No 4 sq.mm. FR PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface /recessed PVC conduit (for equipment wiring round flexible copper cable as per required)
Metre
Metre
Metre
Metre
Metre
Supplying and fixing PVC/G.I box of 200mm x 250mm x 60mm deep on surface or in recess with suitable size of phenolic laminated sheet cover in fornt including painting etc as required (Adopter box above each D.B).
Supplying and fixing PVC/G.I box of 75 mm X 75 mm X 50 mm deepdeep on surface or in recess with suitable size of phenolic laminated sheet cover in fornt including painting etc as required (Adopter box above each D.B).
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps "C" curve, SP MCB, in sheet steel Enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and ommissioning etc. as required.
Supplying and fixing suitable size G.I Box with modular plate and cover in front on surface in recess including providing and fixing 3 pin, 5/6 amps modular socket outlet and 5/6 amps modular type switch, connection, painting etc., as required. (for light plugs to be used in non residential buildings )
Supplying and fixing 12 modules GI box along with moduler base & cover plate surface or in recess including providing and fixing of 4 nos 6 pin 15/16 amps socket outlet with 4 no 15/16A moduler type switch ,connection etc. as required.
Supply & fixing 4 way(4+12) double door TP & N, sheet steel, MCB distribution board, 415 volts, on surface/ in recess, complete with tinned copper busbar, neutral link, earth bar, din bar, detachable gland plate, interconnections, phosphatised and powder painted including earthing etc.as required (But without MCB / RCCB / Isolator) light DB
Supply & fixing 4 way(4+12) double door TP & N, sheet steel, MCB distribution board, 415 volts, on surface/ in recess, complete with tinned copper busbar, neutral link, earth bar, din bar, detachable gland plate, interconnections, phosphatised and powder painted including earthing etc.as required (But without MCB / RCCB / Isolator) Power DB
S/F modular blanking plate on the existing modular plate and switch box excluding modular plate as required.
Main Bus Bar: 4 strip 300 amp bus bar made of electrical grade copper strip enclosed in separate bus bar chamber, provided with DMC/ SMC bus bar support duly insulated with heat shrinkable sleeves in distinct colours as reqd: 1 set (1 Amp per sqmm.)
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as per required.
Supplying and fixing Cable end box (Loose wire box, IP43) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240/415 V, on surface /recess complete with testing and commissioning etc. as required.
Providing and fixing MV danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Providing chemical/mineral maintenance free earthing system comprising of copper coated earth electrode 3 metre length and 17.2 mm outer dia along with 25 kg earth conductivity enhancing back fill mineral compound for earth electrode to fill up the excavated earth and earth inspection pit etc. as required.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required
Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required
P/F 4.00 mm dia.copper wire on surface or in recess for loop earthing along with existing surface /recess for loop earthing along with existing surface/recessed conduit /submain wiring/cable etc required.
Supply & Laying of ISI marked aluminium conductor XLPE insulated cable as per IS 7098, & cable & wirE shall be armoured, served, sheathed 1100 volts grade as per Batra Henley / Havells/ Finolex.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation and refilling the trench etc. as required, but excluding sand cushioning and protective covering.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
Supply and fixing 100 mm dia medium class GI pipe etc as required.
Supply and Installation of regular/standard module AC ceiling fan of 1400 mm sweep including wiring the down rod of standard length 9 upto 30 cm ) with 1.5 sq mm FR pvc insulated copper conductor etc as required.
Supply and Installation of 300 mm 230volt AC exhaust fan in the existing opening including making good the damage connection testing commissioning etc as required.
Supply and installation of 600 mm, 230 V A.C. wall mounted Air circulator, heavy duty fan including fixing the bracket, making onnection, testing, commissioning etc as required.
Supplying and fixing indoor recess mounting 36 watt LED flat panel luminaire suitable for armstrong/grid ceiling and complete with electronic driver etc. directly on false ceiling including connection with 1.5 sqmm fR PVC insulated copper conductor cable and earthing the body etc as required.
Supplying and fixing 90 watt LED type FLOOD light with die cast aluminium housing for ingress protection of IP65 and complete with all accessories etc and connection with FR PVC insulated copper conductor cable and earthing the body etc. as required
Supplying and fixing following LED street/ Flood light with die cast aluminium housing for ingress protection of IP65 and complete with all accessories etc on pole/ building including connection and earthing the body etc. as required.
Supplying and fixing following sizes of PVC conduit along with accessories in surface /recess including cutting the wall and making good the same in case of recessed conduit as required.
Meter
Meter
Supply and fixing of fire extinguisher, ABC Type 4.00kg. Capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.
Supply and fixing of shock treatment chart (prescribed under I. E. rules) duly framed with glass and supported from back with hard board or soft board with supply of all material, labour, T&P for proper completion of work.
Supply and fixing of fire bucket, round bottom made of GI sheet 9-11 litres capacity duly painted as per fire brigade design, supported on hanging bracket chained and locked, initially filled with fine river sand, water as per direction of Engineer-in-Charge.
Providing and fixing carbon-di-oxide fire extingushers trolley mounted with all accessories internal discharge tube, high pressure discharge hose, discharge nozzle, suspension bracket, ISI marked as per IS:2878 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.
SITC AC split(1.5 ton) with stabilizer ISI standard as per specification 5 star inverter AC.. ( Make- blue star/mitsubishi/lg/carrier/Hitachi)
Supplying and fixing modular type 25 amps A.C. unit box with ON/OFF MCB on surface or in recess complete with connections, testing and commissioning etc as required.
Extra copper piping electrical wire for split AC
Extra drain pipe split AC
Supplying and drawing of UTP 4 pair CAT-6 LAN cable in the existing surface/recessed steel /PVC concuitas required.
Category 6 UTP Patch Cords - 1 Mtr Standard Colour - Blue, Grey, Yellow, RJ45 Plug - Polycarbonate plug, Current Rating - 1.5A max, Insulation Resistance - 500MΩ/km(min)@500 Vdc, Contact Resistance - 15 mΩ (max) per contact
Category 6 UTP Patch Cords - 2 Mtr Standard Colour - Blue, Grey, Yellow, RJ45 Plug - Polycarbonate plug, Current Rating - 1.5A max, Insulation Resistance - 500MΩ/km(min)@500 Vdc, Contact Resistance - 15 mΩ (max) per contact
24-port GbE Smart Managed Switch with GbE Uplink Interfaces-24 Ports 10/100/1000Mbps+4 SFP;Port Standards & Functions-IEEE 802.3 10BASE-T Ethernet (twisted-pair copper),IEEE 802.3u 100BASE-TX Fast Ethernet (twisted-pair copper),IEEE 802.3ab 1000BASE-T Gigabit Ethernet (twisted- pair copper),IEEE 802.3az compliance Auto-negotiation,IEEE 802.3x Flow Control; Full/Half Duplex-Full/half duplex for 10/100 Mbps speeds,Full duplex for Gigabit speed;Media Interface Exchange Auto MDI/MDIX adjustment for all twisted-pair ports;Switching Capacity 56 Gbps; Transmission Method Store-and-forward; MAC Address Table 16,000 entries per device, Maximum 64 bytes packet forwarding rate 41.7 Mpps,Packet Buffer Memory 1.5 MB,Maximum Power Consumption 22.45 watts, Standby Power Consumption 17.84 W/240 V, Acoustics 0 dBA Heat Dissipation 76.55 Btu/hr, Operating Temperature -5 to 50 ˚C (23 to 122 °F), Storage Temperature -20 to 70 ˚C (-4 to 158 °F), Operating Humidity 0% to 95% non-condensing, Storage Humidity 0% to 95% non-condensing, Diagnostic LEDs Link/Activity/Speed (Per 10/100/1000 Mbps port), Certifications CE (LVD) BSMICCC, C-Tick. Netgear / D-link/ Cisco.
Category 6, UTP 24-Port Patch Panel Size - 482.6mm x 44.2 (19’’ x 1U), Panel Material - Steel-fully powder coated, Unshielded - RJ 45, Plug Insertion Cycle - 750 times DC Resistance- 72Ω max, Voltage Rating - 72 Vdc max, Current Rating - 1.5A max
Supply fitting fixing Rack 19" 12U fully powder coated complete etc as required with complete accessories (5 amp x 6 socket, wire manager, rack fan) VALRACK/ Netrack make.
Supplying and fixing of RJ 45 computer socket suitable for Cat 6 on module GI box along with base & cover plate in surface or in recess including making connection, soldering etc. as required.
Smart-UPS On-Line, 30 kW /30 kVA with 30 minutes Backup 12 V 42 AH SMF Battery UPS Toplogy Double Conversion On-Line, Power Rating (VA / Watts) 30000Watts/30000VA, Form Factor Rack/Tower Convertible; Output Power Capacity 30000 Watts/30000 VA, Max Configurable Power 30000Watts/30000VA, Nominal Output Voltage 230V, Output Voltage Note Configurable for 220 : 230 or 240 nominal output voltage, Efficiency at Full Load 94.00%, Output Voltage Distortion Less than 3%,Output Frequency (sync to mains) 50/60 Hz +/- 3 Hz,Crest Factor 03:01,Waveform Type Sine Wave, Output Connections (1)*Hard Wire 3-wire (8)*(H N + G) IEC 320 C13(8),Bypass Built-in Bypass, Output Short Circuit Protection Yes,Parallel Redundancy (Option) 1 + 1, Nominal Input Voltage 230V,Input Power Factor>0.98,Input Frequency 40-70Hz,Input Connections Terminal Block, Protection Thermal Circuit Breaker (250VAC/20A), Input voltage range for main operations full load 160 - 285V, Input voltage range for mains operation half load 160-285V, High Voltage withstand Capability 420 VAC, Green Mode Range 210-250 VAC (230 V), Battery Type Mintenance - free sealed Lead-Acid battery with suspended, electrolyte. 12V 42 Ah SMF battery for 30 Min Battery Back up.
SITC of 2MP IR Indoor Dome Fixed Camera- 1/2.8"Progressive Scan CMOS, 1920 × 1080 at 25fps, 2.8 mm Fixed lens, Color: 0.01 Lux at F1.2, ICR, ONVIF, support H.265, H.264, MJPEG, DWDR, 3D Digital Noise Reduction, Tripple individually configurable stream, 12 VDC & PoE, IR range: 40m, IP67, IK10, Edge Anlalytics- Line crossing detection, intrusion detection, Motion detection, video tampering, UL, CE, FCC certified. (DS-2CD3121G0-I (2.8 mm) (Approved Makes: Hikvision/ Honeywell/ Bosch)
SITC of 2MP IR Bullet Fixed Camera -1/2.8"Progressive Scan CMOS, 1920 × 1080 at 25fps, 2.8 mm Fixed lens, 0.01 Lux at F1.2, 0 Lux with IR, ICR, ONVIF (PROFILE S), support H.265, H.264, MJPEG, DWDR, 3D Digital Noise Reduction, Three individually configurable stream, 12 VDC & PoE, IR range: 40m, IP67, Edge Anlalytics- Line crossing detection, Intrusion detection, Motion detection, Scene change detection, Video tampering, UL, CE, FCC certified. (DS-2CD3021G0-I (2.8 mm) (Approved Makes: Hikvision/ Honeywell/ Bosch)
SITC of 64 ch Network Video Recorder - Connect Up to 64 IP Cameras, Dual OS, Up to 12 Megapixels Resolution, Two independent HDMI outputs, one HDMI output of 4K resolution,1 VGA output with output upto 1920 × 1080, Support H.265, MJPEG, Supports N+1 hot spare system,Supports RAID0, RAID1, RAID5, RAID6 and RAID10 ,Supports HDD hot swap, Supports Dual Power-Redundant, Incoming Bandwidth 320 Mbps, 8 SATA Hard Disks, ANR Technology, 8 SATA interfaces for 8 HDDs and capacity of each HDD upto 6TB, 3 × USB at least 1 × USB with 3.0, Alarm I/O 16/4, RS-485, RS-232, 2 RJ-45 10 /100/1000 Mbps self-adaptive Ethernet interface, Multiple network monitoring: Web viewer, CE, FCC, UL certified. (DS-7764NI-I8) (Approved Makes: Hikvision/ Honeywell/ Bosch)
SITC OF 32" LCD 24X7 Surveillance Monitor
SITC of 16 port Unmanaged Network PoE Switch: 24 port PoE Switch with PoE standard of IEEE 802.3af , IEEE 802.3at, PoE port, Uplink ports (DS-3E0326P-E) (Approved Makes: Hikvision/ Honeywell/ Bosch)
SITC OF Cat-6 Cable: UTP CAT 6, 305 meters,Core diameter: 0.53mm,OFC,CM,white (Approved Makes: Hikvision/ Honeywell/ Bosch)
SITC of 6TB Surveillance Hard Disk (ST6000VX0023) (Approved Makes: Hikvision/ Honeywell/ Bosch)
19" 6U Rack for Switches complete as required
Camera installation and Connectivity.
In-ceiling speaker 6" ceiling loudspeaker. 6/3W @ 100V, 100-15,000Hz, 93dB 1W 1M. Dimensions (L x H): 188mm x 76mm, mounting hole 170mm diameter. White( Surface mount speakers to be provided if no provision for ceiling speakers) Make: Cloud UK, Alfatron, Biamp.
Media player, mixer amplifier with Bluetooth. Supplied with remote control. On board tuner and MP3 player. Inputs: Front panel mic. input with priority function, rear panel balanced mic. input with phantom power. Emergency input function. Dual RCA line inputs. Outputs: RCA aux out. 60W at 70/100V and 4-16 Ohms. 24V backup power input.Make:Biamp, Alfatron.
LCD portable projector, 5,000 lumens, WUXGA, 16,000:1 contrast ratio, Aspect Ratio:16:10, Lens (Throw Ratio)1.6x manual zoom (throw ratio: 1.09–1.77:1), manual focus F 1.60–2.12, f 15.30–24.64 mm, Make: Panasonic, Christe, Barco.
113" Diagonal, 16:10 Aspect Ratio, black border on all sides, matt white fabric, motorised with remote and heavy duty Motor. Make AV-craft, grandview.
Projector ceiling mount 1x2, adjustment option. Make TS, B-Tech, Eqv.
Cable Manager with Power socket and HDMI. Make Logic/ Legrand.
C–HM/HM/ETH–50 ( 50 feet) make Kramer / Extron.
Equipment Rack, with Hardware and lock. Make Valrack/ Custom / Eqv.
SITC of 50 LPH RO Water Purifier alng with RO-AUTO MAX 50 lph, hdrophenumatic tank-10 LPH, Faucet-1 nozzle, accessories- clip, inlet & outlet pipe etc.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
NIT-12.pdf
NIT • 1.68 MB
JVG.pdf
NIT • 1.20 MB
CHECK LIST FOR CONTRACTORS.pdf
NIT • 1.76 MB
NIT-12.pdf
NIT • 1.68 MB
Spl Condition.jpeg
NIT • 0.17 MB
Munsi Singh College BOQ.xls
NIT • 0.46 MB
SBD Munsi Singh College.doc
NIT • 11.59 MB
Munsi Singh College BOQ.xls
NIT • 0.46 MB
C4 PRE BID QUERY NIT-12GR02.pdf
Corrigendum • 7.17 MB
C3 CORRIGENDUM NIT-12 GR02.PDF
Corrigendum • 0.62 MB
C2 Corrigendum-1.pdf
Corrigendum • 0.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .