| 1 | L1₹31.5 LAccepted-AOC ROOM NO 220 2ND FLOOR DEVGIRI BUILDING NO 65 B LALLU BHAI COMPOUND MANKHURD MUMBAI 400043 | MUMBAI SUBURBAN | MAHARASHTRA | 400043 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹34.5 L+₹3.0 L (9.47%)Rejected-AOC UNIT NO 7 MOUNT VIEW CO OP HOUSING SOCIETY LIMITED MUMBAI MANKHURD 400 088 | MUMBAI SUBURBAN | MAHARASHTRA | 400088 | L2 | Rejected-AOC NOT LOWEST | |
| 3 | L3₹37.7 L+₹6.2 L (19.6%)Rejected-AOC | L3 | Rejected-AOC NOT LOWEST | |
| 4 | L4₹38.2 L+₹6.7 L (21.1%)Rejected-AOC ATLANTIS A2 1501 PLOT NO 05 SECTOR 11 NEAR CLOUD 36 GHANSOLI NAVI MUMBAI 400 701 E 97 CWE SUBS BHANDUP | THANE | MAHARASHTRA | 400701 | L4 | Rejected-AOC NOT LOWEST | |
| 5 | L5₹38.4 L+₹6.8 L (21.7%)Rejected-AOC 300 STREET NO 10 PREM BASTI SANGRUR PB PUNJAB 148001 | SANGRUR | SANGRUR | PUNJAB | 148001 | L5 | Rejected-AOC NOT LOWEST |
Tender Value
₹47.5 L
EMD Value
₹95,000
Closing Date
20 Apr 2024, 6:00 pmClosed
GE (NW) MANKHURD
GE (NW) MANKHURD MUMBAI_88
REPAIRS TO ROLLING SHUTTERS, ROOF SHEETS, FALSE CEILING, VALLEY GUTTERS,DAMAGED SECURITY WALL, AREA DRAINAGE, HARD STANDING, FOOTPATH, CHAINLINK FENCING, PARKING SHED, GATES AND MISC WKS IN AT WED, SAW MILL NSD AND DSRV UNDER GE (NW) MANKHURD
2024_MES_648708_1
8336/E8
Open Tender
Civil Works
Item Rate
180 days
GE (NW) MANKHURD
As per NIT and Tender Documents
9 documents required · 9 mandatory
₹500
GE (NW) MANKHURD
₹95,000
20 Jul 2024
30 Mar 2024
22 Apr 2024
30 Mar 2024
20 Apr 2024
12 Apr 2024
Amount
Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings as specified
S&F Pre- painted galvalume sheet having aluminum zinc coating with hot dip alloy of 55% Aluminium 43.5% Zinc 1.5% Silicon and finished with resin coat on both surfaces @ 150 gm/sqm of coating (total both surfaces) having overall width and laid width as specified GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with fixed using hot dip galvanized, self drilling and self tapping screws neoprene and EPDM washers. Penetrations and laps in sheet shall be sealed by using proper sealant profile. HDPE fillers shall be provided wherever required to close voids between sheets, sheet & fastners etc. completely all as specified and directed. upto maximum height of 20 Mtr including scaffolding and all safety equipments as required. Note : No additional payment on any account will be considered and only plan area whatever have been provided will be measured. Rate quoted maybe considered including of bending for specific curvature as provided in existing building.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet in ridge 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified upto maximum height of 20 Mtr including scaffolding and all safety equipments if required. Note : No additional payment on any account will be considered and only plan area whatever have been provided will be measured. Rate quoted maybe considered including of bending for specific curvature as provided in existing building.
Taking down cement plaster of any description from brick or stone walls including raking out joints, hacking for key , scrubbing down with water etc and removing debris outside MD land complete all as specified
M&L for rendering 15mm thick in two coats (10+5mm) polymer modified ready mix cement based plaster on the wall surfaces including finishing the surface of top layer even and smooth complete all as specified and directed make: easyplast from wall plast/readiplast from ultratech including material and labour for preparation of new plastered surfaces on walls, preparation for Acrylic emulsion and applying applying two coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resisitance as per IS 15489:2004, alkali & fungal rsistance, dirt resistance exterior paint of required shades(Company Depot Tinted) with silicon additives @ 1.43 litre/10sqm over & including priming coat of extreior primer applied @ 0.90 litre/10 sqm over new surfaces complete all as specified
M&L for rendering 10mm thick polymer modified ready mix cement based plaster on the wall surfaces including finishing the surface of top layer even and smooth complete all as specified and directed make: easyplast from wall plast/readiplast from ultratech including material and labour for preparation of new plastered surfaces on walls, preparation for distempering and applying two coat of oilbound distemper over a coat of primer including stopping of nails holes,cracks etc and 1 mm thick (minimum) white cement based wall care putty on old surfaces of walls etc, finished even and smooth, complete all as specified and directed.
M&L for rendering 5mm thick polymer modified ready mix cement based plaster on the wall surfaces including finishing the surface of top layer even and smooth complete all as specified and directed make: easyplast from wall plast/readiplast from ultratech including material and labour for preparation of new plastered surfaces and applying three coats of white wash complete all as specified and directed.
M&L for rendering 15mm thick in two coats (10+5mm) Cement plaster in CM 1:3 on the wall surfaces including finishing the surface of top layer even and smooth complete all as specified and directed
M&L for rendering 10mm thick Cement plaster in CM 1:3 on the wall surfaces including finishing the surface of top layer even and smooth complete all as specified and directed
M&L for structural repairs to columns, beams, slabs and chajjas at maximum height of 16 mts including scaffolding and safety measurements completely all as specified and directed by Engineer-in-charge in following steps as mentioned below 1) Chipping , Removing,Carefullly Loose Concrete work by low impact Hammer/Breakar without damaging the structure & cleaning and disposal of malba out side the premises etc. complete as directed. Hard concrete should not be removed by force. 2) M&L for cleaning existing reinforcement with wire/ rotary wire brush to a shining bright finish, making the surfaces free from loose material, dirt etc complete and applying two coats of alkaline rust converting primer conforming to ASTM-B-117 of make. "Feovert" of "Krishna Conchem" OR "Roff Rust Cleaner' of 'Pidilite' OR 'Shali Rustoff' of 'STP Ltd', on rebars with time interval of 1 hr between the coats, complete all as specified and directed. (Note :- Mode of measurement: superficial area of concrete will be measured.) 3) M&L for Anticorrosive Treatment to Reinforcement using Corroseal - ZR of M/s Krishna Conchem or Epoxy Zinc Primer of M/s. Dr. Fixit by application on exposed reinforcement in two coats with time interval of minimum 4 hours between each coat. The application shall be done by brush after cleaning/wire brushing to the exposed steel surfaces, complete all as specified and directed. 4) M&L for Epoxy bond coat of Make Fosroc (NITOBOND-EP) OR EPOXY BONDING AGENT of Dr. Fixit OR equivalent of M/s. Krishna Conchem as approved by GE over exposed concrete surfaces prior to application of any type of mortar to ensure bond between old concrete & new concrete by brush application, complete all as specified and directed. 5) M&L for building up the profile of structural members by using polymer modified mortar from M/s. Krishna Conchem (Molith-PMM) OR Polymer mortar HB of Dr Fixit upto 40mm thickness including levelling, profiling etc in two layers, each layer not exceeding 20mm, complete all as specified and directed. 6) M&L for rendering 15mm thick in two coats (10+5mm) polymer modified ready mix cement based plaster on the wall surfaces including finishing the surface of top layer even and smooth complete all as specified and directed make: easyplast from wall plast/readiplast from ultratech including material and labour for preparation of new plastered surfaces on walls, preparation for Acrylic emulsion and applying applying two coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resisitance as per IS 15489:2004, alkali & fungal rsistance, dirt resistance exterior paint of required shades(Company Depot Tinted) with silicon additives @ 1.43 litre/10sqm over & including priming coat of extreior primer applied @ 0.90 litre/10 sqm over new surfaces
M&L for structural repairs to columns, beams, slabs and chajjas at maximum height of 10 mts including scaffolding and safety measurements completely all as specified and directed by Engineer-in-charge in following steps as mentioned below 1) Chipping , Removing,Carefullly Loose Concrete work by low impact Hammer/Breakar without damaging the structure & cleaning and disposal of malba out side the premises etc. complete as directed. Hard concrete should not be removed by force. 2) M&L for cleaning existing reinforcement with wire/ rotary wire brush to a shining bright finish, making the surfaces free from loose material, dirt etc complete and applying two coats of alkaline rust converting primer conforming to ASTM-B-117 of make. "Feovert" of "Krishna Conchem" OR "Roff Rust Cleaner' of 'Pidilite' OR 'Shali Rustoff' of 'STP Ltd', on rebars with time interval of 1 hr between the coats, complete all as specified and directed. (Note :- Mode of measurement: superficial area of concrete will be measured.) 3) M&L for Anticorrosive Treatment to Reinforcement using Corroseal - ZR of M/s Krishna Conchem or Epoxy Zinc Primer of M/s. Dr. Fixit by application on exposed reinforcement in two coats with time interval of minimum 4 hours between each coat. The application shall be done by brush after cleaning/wire brushing to the exposed steel surfaces, complete all as specified and directed. 4) M&L for Epoxy bond coat of Make Fosroc (NITOBOND-EP) OR EPOXY BONDING AGENT of Dr. Fixit OR equivalent of M/s. Krishna Conchem as approved by GE over exposed concrete surfaces prior to application of any type of mortar to ensure bond between old concrete & new concrete by brush application, complete all as specified and directed. 5) M&L for building up the profile of structural members by using polymer modified mortar from M/s. Krishna Conchem (Molith-PMM) OR Polymer mortar HB of Dr Fixit upto 40mm thickness including levelling, profiling etc in two layers, each layer not exceeding 20mm, complete all as specified and directed. 6) M&L for rendering 10mm thick polymer modified ready mix cement based plaster on the wall surfaces including finishing the surface of top layer even and smooth complete all as specified and directed make: easyplast from wall plast/readiplast from ultratech including material and labour for preparation of new plastered surfaces on walls, preparation for distempering and applying two coat of oilbound distemper over a coat of primer including stopping of nails holes,cracks etc and 1 mm thick (minimum) white cement based wall care putty on old surfaces of walls etc, finished even and smooth, complete all as specified and directed.
M&L for structural repairs to columns, beams, slabs and chajjas at maximum height of 10 mts including scaffolding and safety measurements completely all as specified and directed by Engineer-in-charge in following steps as mentioned below 1) Chipping , Removing,Carefullly Loose Concrete work by low impact Hammer/Breakar without damaging the structure & cleaning and disposal of malba out side the premises etc. complete as directed. Hard concrete should not be removed by force. 2) M&L for cleaning existing reinforcement with wire/ rotary wire brush to a shining bright finish, making the surfaces free from loose material, dirt etc complete and applying two coats of alkaline rust converting primer conforming to ASTM-B-117 of make. "Feovert" of "Krishna Conchem" OR "Roff Rust Cleaner' of 'Pidilite' OR 'Shali Rustoff' of 'STP Ltd', on rebars with time interval of 1 hr between the coats, complete all as specified and directed. (Note :- Mode of measurement: superficial area of concrete will be measured.) 3) M&L for Anticorrosive Treatment to Reinforcement using Corroseal - ZR of M/s Krishna Conchem or Epoxy Zinc Primer of M/s. Dr. Fixit by application on exposed reinforcement in two coats with time interval of minimum 4 hours between each coat. The application shall be done by brush after cleaning/wire brushing to the exposed steel surfaces, complete all as specified and directed. 4) M&L for Epoxy bond coat of Make Fosroc (NITOBOND-EP) OR EPOXY BONDING AGENT of Dr. Fixit OR equivalent of M/s. Krishna Conchem as approved by GE over exposed concrete surfaces prior to application of any type of mortar to ensure bond between old concrete & new concrete by brush application, complete all as specified and directed. 5) M&L for building up the profile of structural members by using polymer modified mortar from M/s. Krishna Conchem (Molith-PMM) OR Polymer mortar HB of Dr Fixit upto 40mm thickness including levelling, profiling etc in two layers, each layer not exceeding 20mm, complete all as specified and directed. 6) M&L for rendering 5mm thick polymer modified ready mix cement based plaster on the wall surfaces including finishing the surface of top layer even and smooth complete all as specified and directed make: easyplast from wall plast/readiplast from ultratech including material and labour for preparation of new plastered surfaces and applying three coats of white wash complete all as specified and directed.
M&L for providing CRS TMT bars any dia in various structural RCC elements like columns, beams, Slabs etc. including cutting, bending, fixing of bars with welding/ tying as required at site with & including binding wires etc. and all relevant works like anchoring of the bars in the existing RCC Members, complete all as specified and directed.
Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc
M&L Vitrified Coloured Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over screed bed or bedding layer 15mm thick for laying floor finishes in cement mortar 1:6 to recive tiles/stone slabs including skirting with backing coat complete all as specified and directed by EIC.
Non-skid Coloured Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over screed bed or bedding layer 15mm thick for laying floor finishes in cement mortar 1:6 to recive tiles/stone slabs including skirting with backing coat complete all as specified and directed by EIC.
Non-skid Coloured Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over screed bed or bedding layer 15mm thick for laying floor finishes in cement mortar 1:6 to recive tiles/stone slabs complete all as specified and directed by EIC.
Non-skid Coloured Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over screed bed or bedding layer 15mm thick for laying floor finishes in cement mortar 1:6 to recive tiles/stone slabs including skirting with backing coat complete all as specified and directed by EIC.
Glazed ceramic coloured tiles in vertical surface 300x 450x 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match (dado) including 10 mm thick back coat of cement plaster on fair faces of brick work 1:3
S&F uPVC vent cowl 110mm bore with and including rubber ring joints, complete all as specified and directed.
S&F uPVC vent cowl 75 mm bore with and including rubber ring joints, complete all as specified and directed.
S&F in repairs110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls all complete all as specified and directed.
S&F 110mm bore PVC (SWR) branch piece single (Single Y ) equal or unequal with access door
S&F 110mm bore PVC (SWR) bend with access door
S & F in repairs PVC (SWR) bend 75 mm with access door
S & F in repairs PVC (SWR) bend 75 mm without access door
S & F in repairs PVC (SWR) bend 110 mm with access doors
S & F in repairs PVC (SWR) bend 110 mm without access doors
S & F in repairs PVC (SWR) branch piece, single (single Y) equal or unequal,75 mm
S & F in repairs PVC (SWR) branch piece, single (single Y) equal or unequal,75 mm with access door
S & F in repairs PVC (SWR) branch piece, single (single Y) equal or unequal,110mm
S & F in repairs PVC (SWR) branch piece, single (single Y) equal or unequal,110mm with access door
S & F in repairs PVC (SWR) branch piece, double (double Y) equal or unequal,75 mm
S & F in repairs PVC (SWR) branch piece, double (double Y) equal or unequal,75 mm with access door
S & F in repairs PVC (SWR) branch piece, double (double Y) equal or unequal,110mm
S & F in repairs PVC (SWR) branch piece, double (double Y) equal or unequal,110mm with access door
S & F in repairs 40 mm bore PVC pipes single socketed in any length jointed and fixed to walls and floors for spouts, washbasin outlet
S&F in repairs vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white with integral foot rests with flush pipe of 32mm dia including 10 ltr capacity low level flushing cistern with necessary PVC connections 15mm size with PTMT nuts of length 450mm long etc complete.
S&F vitreous China wash basin white, flat back size 550 x 400mm including 15mm dia pillar tap, CP waste coupling, chain and plug, waste fitting, union and waste pipe 32mm dia of required length and all necessary 450mm long outlet and inlet PVC connections pipes with PTMT check nuts complete.in repair
S&F in repairs vitreous coloured China Europeon water closet (Pedestal Pattern) including 10 ltr capacity low level flushing cistern with flush pipe of 32mm dia including necessary PVC connections 15mm size with PTMT nuts of length 450mm long etc complete.
Taking up or down steel tubing and connection, removing clear off site after credit for the same is recovered by the dept., bore of pipe 15mm and Supply & fixing 15 mm bore GI tubing, medium grade with and including all fittings and fixed to walls and ceilings or laid in floors complete all as specified and as directed.
Taking up or down steel tubing and connection, removing clear off site after credit for the same is recovered by the dept., bore of pipe 15mm complete all as specified and directed.
Taking up or down steel tubing and connection, removing clear off site after credit for the same is recovered by the dept., bore of pipe 20mm complete all as specified and directed.
Taking up or down steel tubing and connection, removing clear off site after credit for the same is recovered by the dept., bore of pipe 40mm complete all as specified and directed.
Taking up or down steel tubing and connection, removing clear off site after credit for the same is recovered by the dept., bore of pipe 25 mm complete all as specified and directed.
S&F Unplasticised PVC pipes of 15mm bore of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipe
S&F in repairs 10 ltr, PVC, valveless, syphonic action type, flushing cistern, low level/ high level including inlet, ball valve, float and handle including brackets with and including PVC flush pipe 32 mm bore, of suitable length as per site requirement connecting to WC etc, and connections to pipes and fixing of chain and pull, or lever, if any complete all as specified and directed.
S&F in repairs CP stop cock 15mm bore fancy type chromium plated with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S&F in repairs CP bib tap 15mm bore fancy type with crutch or butterfly handle, screwed for iron pipe or for unions and fixed complete all as specified and directed.
S&F in repairs CP pillar taps 15mm bore, cast copper alloy, chromium plated fancy type complete all as specified and directed.
S&F in repairs waste fitting of 32 mm bore brass, chromium plated for glazed ware wash basin etc complete all as specified and directed.
S&F in repairs waste fitting of 40 mm bore brass , chromium plated for glazed ware for sink coulpling etc complete all as specified and directed.
S&F in repairs waste pipe for WHB 32mm bore fixed to wash hand basin coupling length pipe 0.90 mtrs each complete all as specified and directed.
S&F in repairs waste pipe for kitchen sink 40mm bore fixed to sinks coupling length pipe 0.90 mtrs each complete all as specified and directed.
S&F in repairs stainless steel grating in round shape 100mm dia with one hole for waste pipe complete all as specified and directed.
S&F in repairs stainless steel grating in ground shape 100mm dia without hole complete all as specified and directed.
S&F GI Tubes 15mm bore, 'medium grade' galvanised,with all fitting and fixed complete to walls and ceilings or laid in floor complete all as specified and directed
S&F low density polyethene pipes (LDPE) 32mm of pressure rating 6 Kg/cm2 fixed to walls or laid in floors etc.
S&F in repairs Health faucet with 1 mtr tube & hook complete all as specified and directed.
S&F in repairs two way Bib cock long body with wall flange fitted by 15mm bore complete all as specified and as directed
S & F PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement
S&F sinks made of stainless steel 1mm thick kitchen or laboratory with plugs,washers and waste pipe including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting unions to pipe, overall size 495mmx420mm bowl size 410mmx330mmx160mm complete iincluding demolition of old cudappah sink/old sink all as specified and as directed.
Supply & fixing 20mm CPVC pipes UV stable,leak proof, tough ,rigid , conforming to IS:15778 of SDR 11 standard., medium grade with and including all fittings and fixed to walls and ceilings or laid in floors, complete all as specified and as directed.
Supply & fixing 40 mm bore GI tubing, medium grade with and including all fittings and fixed to walls and ceilings or laid in floors complete all as specified and as directed.
Supply & fixing 25 mm bore GI tubing, medium grade with and including all fittings and fixed to walls and ceilings or laid in floors complete all as specified and as directed.
S&F in repair for gun metal globe or gate valves with iron wheel head , screwed both ends for iron pipe & fixed of size 20mm bore complete all as specified and directed.
S&F in repair for gun metal globe or gate valves with iron wheel head , screwed both ends for iron pipe & fixed of size 15 mm bore complete all as specified and directed.
Taking down chowkhat or frame (without taking off shutter from the frame) not exceeding 1.5 Square Metre each , removing from the site including cutting holes required for taking out existing hold fast etc. complete all as specified and as directed.
All as per Item No 68 above but exceeding 1.5 Square Metre and not exceeding 04 Square Metre each complete all as specified and directed.
Solid PVC Door Frame of size 50mmx 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing
M&L for factory made solid PVC panel type PVC door shutter 30mm thick consisting of frame madeout of MS tubes for top and bottom rails MS frame shall be covered with moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail and bottom rails, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles and rails with suitable PVC sheet beading and jointed together with solvent supplying and fixing in the frame at site as per specifications and drawing given under SSR Part II 2020 complete all as specified and directed
Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 50 x 100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp ressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). all as specified and directed. Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account will be provided
Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 35 mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge.
M & L for 20 to 25mm machine cut, polished cudappah stone slab, , in window cill, kitchen platform and similar work, laid over and including backing coat, in CM 1:4, 15 mm thick, jointed with grey cement slurry mixed with pigment to match the shade of the slab including taking down/dismantling old one complete all as specified and as directed
M&L Granite (of any type) Tiles 20mm thick in floor machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including 20mm thick CM 1:6 screed bed for laying floor finishes and cutting and polishing complete all as specified and as directed.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations
Taking down carefully existing aluminium sliding window shutters,(glass/wire mesh) /frame not exceeding 1.5 Square Metre each and re-fixing the shutters in existing position, after repairing complete all as specified and directed.
All as per Item No 77 above but exceeding 1.5 Square Metre and not exceeding 04 Square Metre.
S&F standard aluminum section powder coated in partition / frame and door shutter, sliding windows / ventilators and places otherwise not specified cut to size, jointed with cadmium plated steel screws, including rubber beading or gaskets for fixing glass or wire cloth or Bakelite sheet and all necessary fittings, hinges, screws, plugs, locking arrangements for windows, Nylon ball bearing etc completed all as specified and directed (Aluminum section shall be of make Jindal / Hindalco / Indalco). Note :- Weight of Aluminum sections for frames and shutters shall be only considered for payment. Cost of other consumables required for the item shall be deemed to be included in the quoted rate. However glass panes / Bakelite sheet / wire cloth / mortice lock / locking stay / floor spring / floor door stopper only will be measured and paid separately under respective items as supply only. Fixing by element of these items shall be deemed to be included in quoted rate.
S&F for 4.80mm thick glass ordinary quality plain with including wooden/rubber beading or gasket for aluminium section complete all as specified
S&F for 3.0mm thick pin head glass with including wooden/rubber beading or gasket for aluminium section complete all as specified
S&F aluminum anodised grill DG- 104 of Deco grill or equivalent fixed with 'F'/'U' section approved make all as specified and directed. Note : (i) Make shall be of M/s Decogrille of M/s Associated Groups or equivalent as approved by the GE. (ii) Minimum thickness of anodizing shall be 15 microns.
Supply only stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with in wooden windows, doors etc and including M&L for fixing of teak wooden beading of suitable size all around complete all as specified and as directed by the Engineer-in-Charge.
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position.(Any Size/Capacity)
Dismantling completely existing roof treatment (excluding cement screed bed ) including loosened cement plaster and exposing the top surface of RCC slab and making good the same in CM 1:4 and removing rubbish, etc to a distance exceeding 500m and not exceeding 1.0km complete all as specified and directed by the Engineer-in-charge
M&L for PCC (1:2:4) type B-1, using 20mm graded stone aggregate as in leveling course over RCC roof/ terrace surfaces to achieve required slope, benching etc including making rounded or chamfered on edges mixed with WPC(water proofing compound) as per manufacturer's instructions, complete all as specified and directed. Note : WPC shall be measured and paid separately as "supply only".
Supply only Integral waterproofing compound.
i) M&L for preparation of surface including cleaning of all dirts and provide the following water proofing treatment in Accessible Roof/Inaccessible Roof & terrace, narrow width over the roof gutter of store houses or chajjas etc. ii) Apply oil bound bitumen primer @ 0.25 gm/Sqm manufacturer by the same agency as that of APP with density of 0.87-0-89 Kg litr at 25 c on the prepared dry roof surface provide and lay APP modified water proofing membrance reinforced with non wooven polyster matt with physical properties as under :- (aa) Membrane Weight - not less than 3.0 Kg/Sqm (ab) Non woven polyster weight - 160 gm /Sqm (ac) Joint Tensile strength Longiutinal - 650 N/Sqcm Tranverseand longitudnal - 350/Sqcm (ad) Tear strength Longiutinal - 300N /cm Tranverse - 250N/cm Direction (ae) Impermeability underwater pressure 2Kgf/Sqcm (iii) APP membrane shall be laid using butaretorch by Torch on application with minimum 10cm side overlap and 15cm end lap. The laying of membrance shall be got, done through an authroiset applicate of Manufacture of membrane. (iv) Over the membrane provide a finishing with solar reflective bitumen aluminium to inaccesible roof. paint @ 0.10 Kg/Sqm as prescribed by manufacturer
M&L for preparation of old plastered surfaces on walls, preparation for Acrylic emulsion and applying applying one coat of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resisitance as per IS 15489:2004, alkali & fungal rsistance, dirt resistance exterior paint of required shades(Company Depot Tinted) with silicon additives @ 1.43 litre/10sqm over & including priming coat of extreior primer applied @ 0.90 litre/10 sqm over new surfaces
M&L for complete removal of existing treatment by washing, rubbing down and stopping of old decorated surfaces on walls, preparation for distempering and applying two coat of oilbound distemper over a coat of primer including stopping of nails holes,cracks etc and levelling with minimum 1 mm thick white cement based wall care putty for obtaining plain surface complete all as specified and directed.
M&L for Complete removal of existing treatment and preparation of plastered surfaces on walls, preparation for Acrylic emulsion and applying applying two coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resisitance as per IS 15489:2004, alkali & fungal rsistance, dirt resistance exterior paint of required shades(Company Depot Tinted) with silicon additives @ 1.43 litre/10sqm over & including priming coat of extreior primer applied @ 0.90 litre/10 sqm over new surfaces
M & L for preparation of old distempering surfaces including stopping of nails holes,cracks etc. and applying one coat of oil bound distemper on wall complete all as specified.
Preparation of old surfaces on ceiling (plastered or unplastered or previously white washed) and applying one coat of white wash complete all as specified.
Preparation of old surfaces on wall (plastered or unplastered or previously white washed) and applying one coat of white wash complete all as specified.
M & L for preparation of old wooden surfaces of any description over 10cm width or girth & applying one coat of synthetic enamel paint complete all as specified.
M & L for preparation of old steel surfaces of any description over 10cm width or girth & applying one coat of synthetic enamel paint complete all as specified.
M & L for preparation of old steel surfaces of any description over 10cm width or girth & applying one coat of aluminium paint complete all as specified.
M&L for preparation of old painted surfaces of any description and applying one coat of cement base paint on wall with necessary scaffolding arrangement. Note: The contractor shall clean the window panes including splashes of paint etc and the quoted rate is deemed to be included for the same.
M&L for forming V grooves in plaster n exc 5 mm deep and n exc 5 mm on face and filling cracks with crack X paste of M/s Dr fixit or with eequivalent of M/s STP Ltd including necessary scaffolding
M&L for forming V grooves in plaster exc 5 mm deep and exc 5 mm on face and filling cracks with cement mixed with M/s Dr fixit or equivalent of M/s STP Ltd including necessary scaffolding
M&L for dismantling of ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets
S&F Anodised aluminium snap grid frame work for false ceiling all as specified fixed using Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified
Providing and fixing Gypsum Board 12mm thick in ceiling fixed with screw as per manufacturers instructions
Dismantling fencing wire mesh, any type
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire
S & F framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290 Gde E 165
S&F 1.0mm Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 with welded or soldered joints. Note : A sum of Rs 74,391.00 towards sch of credit shall be deducted to arrive the contract sum
Joy builders
AM ENTERPRISES
M/s Shree Construction Co
KRISHNA ENGINEERS
Advait Enterprises
RAJU AND COMPANY
M/s Mohd Altaf Hanif Qureshi
Parmatma Enterprises
Vishal Builders
M/s Hari Om Construction
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .