| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.0 LAccepted-AOC 20 1ST A CROSS SAI NAGAR AREHLLI UTTARHALLI BANGALORE 560 061 | BENGALURU URBAN | KARNATAKA | 560061 | L1 | Accepted-AOC L1 | |
| 2 | L2₹45.0 L+₹31,363.50 (0.70%)Rejected-Finance | L2 | Rejected-Finance Rejected being L2 | |
| 3 | L3₹45.4 L+₹74,991 (1.68%)Rejected-Finance | L3 | Rejected-Finance Rejected being L3 | |
| 4 | L4₹49.8 L+₹5.1 L (11.5%)Rejected-Finance M S RRK PROJECTS D 306 ADG P CHENNAI 11 3RD CROSS SIR MV LAYOUT VIDHYARANYAPURA POST BANGALORE 560097 | BENGALURU URBAN | KARNATAKA | 560097 | L4 | Rejected-Finance Rejected being L4 | |
| 5 | L5₹49.9 L+₹5.2 L (11.7%)Rejected-Finance | L5 | Rejected-Finance Rejected being L5 |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
26 Apr 2023, 6:00 pmClosed
GE I RD East Bangalore
GE I RD East Bangalore 93
REPAIR TO DRAIN PATH SECURITY WALL BARBED WIRE STEEL GATE AND OTHER CONNECTED MISC WORKS AT PHII ZONE A ZONE B PH III AND CASDIC UNDER GE I RD EAST BANGALORE
2023_MES_588248_1
8388
Open Tender
Civil Works
Item Rate
270 days
GE I RD East Bangalore
D a (i)
8 documents required · 8 mandatory
₹500
Yes
GE I R AND D East Bangalore
₹92,000
Yes
20 Nov 2023
5 Apr 2023
28 Apr 2023
6 Apr 2023
26 Apr 2023
19 Apr 2023
6 Apr 2023 - 12 Apr 2023
Amount
Demolition of Brickwork or stone boulder masonry/PCC block masonry, built in cement mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework & precast complete all as specified and directed.
Material and Labour walling of random rubble stone masonry, uncoursed, well bonded, bedded and solidly, hearted, built in CM 1:6 complete all as specified and directed.
All the same as per item No 2 above,but Walling of random rubble stone masonry, uncoursed, well bonded, bedded and solidly, hearted, built in CM 1:6 but except stone complete all as specified and directed Note :- Serviceable stones obtained from demolition of stone masonry shall be reused in the work.
M & L Brickwork with sub class B bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified and directed
All the same as per item No 4 above, but brick work with sub class B bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) but except bricks complete all as specified and directed
M&L for Pre cast cement concrete block masonry with solid block using PCC 1:3:6, type C1 (using 20 mm graded stone aggregate) exc 10 cm in width and setting in mortar 1:6 complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floor and paving n exc 15cm below or above ground level complete all as specified and disposing off rubbish outside MD land complete all as specified and directed.
M&L 75mm thick PCC type D-2, (1:4:8) using 40mm graded stone aggregate as in sub base complete all as specified and directed.
Material and labour for 75mm thick PCC (1:3:6) type C-1 using 20mm graded crushed stone aggregate as in paving/plinth protection, hardstanding laid in panels and joints filled with mix of bitumen and sand (1:3) by weight, finished the surface even and fair without using extra cement complete all as specified and directed.
Dismantling of floor,hearth or wall tiling including cement mortar bedding and disposing off rubbish outside MD land complete all as specified and directed.
M&L for Chequered cement concrete tiles of size 25cmX25cmX25mm /30cm x 30cm x 25mm thick with grey cement and pigment set jointed and pointed in neat cement slurry laid e over 15mm thick Screed bed in CM 1:4 all as specified and as directed.
M&L Factory made special shaped precast machine pressed kerb stone using M-25 grade concrete including dismantling of existing kerb stone of any type/description and necessary earthwork and set in CM 1:6 including disposing off rubbish outside MD land complete all as specified and directed.
Demolition of cement concrete (un-reinforced) any description & in any position not otherwise specifically provided for as in coping, benching, bed block etc and disposing off rubbish outside MD land complete all as specified and directed.
M&L PCC in foundations, filling and mass-concrete type D2 (1:4:8) using 40 mm graded stone aggregate complete all as specified and directed
M&L for PCC in 1:2:4 type B1 (using 20mm graded stone aggregate) as in coping, benching and similar work incl form work complete all as specified and directed
M&L PCC in surface channels and drains type B2 (1:2:4) using 40 mm graded stone aggregate complete all as specified and directed
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitered/stopped end etc complete all as specified and directed
Add or deduct for each 25 mm girth or part thereof over or under 30 cm ditto complete all as specified and directed
Demolition of RCC of any description & in any position (reinforcement cut as required to facilitate demolition) and disposing off rubbish outside MD land complete all as specified and directed.
M&L for TMT bars 10mm dia and over cut to length bent to shape required including cranking bending etc and binding with mild steel wire (annealed) not less then 0.90 mm complete all as specified and directed
M&L Precast RCC 1:2:4 type B1 (using 20mm stone aggregate) as in cover slab of drain, culvert and the like set in CM 1:4 all as specified and as directed.
Taking down cement plastering of any thickness on brick, concrete or stone walls, partitions, etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and as directed
M&L for 15mm thick rendering on brick or concrete surface in cement mortar 1:4 and finishing the surface with even and smooth without using extra cement all as specified and as directed.
M&L for 15mm thick rendering on stone wall surface in cement mortar 1:4 and finishing the surface with even and smooth without using extra cement all as specified and as directed.
M & L for flush pointing to squared rubble masonry coursed or uncoursed in cement mortar 1 :3 complete all as specified
M&L for Applying two coats of cement base paint over primer on new wall surface including preparation of surface.
M & L for preparation of old wall surfaces and applying one coat of cement base paint complete all as specified and as directed.
Cutting holes in stone/Precast concrete walls built in cement mortar complete as specified and as directed
Cutting holes in brick walls built in cement mortar or stone walls built in lime mortar complete as specified and as directed
Dismantling wrought iron of mild steel work of any description not otherwise provided for complete all as specified and as directed by the Engr-in-Charge.
S&F framed work such as grills, gratings and similar work etc., with ends of bars shouldered and/or riveted, or forged into spikes; ; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290-0 Gde E-165 complete all as specified and directed
S&F for expanded metal weight not exceeding 4.00 Kg per Sqm, cut to length, bent to shape required & tying with including necessary welding steel frame work complete all as specified and direceted.
Fixing only for rolled mild steel framed work as in grating/grill/gates including pintle hinges and similar work of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed
Fixing only Expanded metal retrived from dismantling including necessary welding and repair and welded with MS frame etc complete all as specified and directed.
Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground (Posts embedded in concrete) complete all as specified.
All the same as per item No 35 above but dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed portion and Posts embedded in concrete complete all as specified and as directed
M&L for posts and struts in wall fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 410-0 or Fe 310-0 complete all as specified and as directed by the Engineer-in-Charge
Taking down existing barbed wire fencing, supply and fix, new barbed wire fencing, galvanized, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanized mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) complete all as specified and directed.
S&F in repairs Chain link fencing of MS galvanized wire of 3.5mm dia and size of mesh 75mmx75mm and fixing to any type of post, rail with straining bolts including provision of binding wire complete all as specified and as directed
M & L for two coats of Synthetic enamel paint to new steel surfaces over 10 cm width or girth over a coat of red oxide primer including preparation complete all as specified and directed
M&L for applying one coat of synthetic enamel paint on steel & iron surfaces of any description, not otherwise, described, over 10cm width or girth including preparation of old painted surface complete all as specified and directed
Desilting and cleaning of blocked storm water drain/nallaha and culvert etc by removal of mud, soil, aggregate and other similar waste material for smooth flowing/functioning of storm water and disposing off rubbish outside MD land complete all as specified and directed.
Cleaning of roof top surfaces of any type/description, height by removing tree leaf any other similar waste material carefully to avoid damage of existing roof treatment including cleaning of rain water pipes of any description and any size for smooth flowing of rain water and removing the debris out side MD land complete all as directed.
Uprooting scrubs/plant/flora & fauna on wall girth not exceeding 100mm from brick wall by cutting holes into masonry/walls for digging out roots and dosing Sulfuric/Phenolic Acid as per manufacturer's instruction to burn deep rooted tree roots and making good the disturbed area with cement mortar in CM 1:3 using water proofing compound including necessary scaffolding etc complete all as specified and directed
M&L for PCC in 1:3:6 type C-1 (using 20mm graded stone aggregate) as in kneelers, apex stones, bed plates, kerbs, water trought & the like including weathering, slightly rounded or chamfered angles & throating, incl form work complete all as specified and directed
M&L applying two coats of synthetic enamel paint on brick, stone, concrete, asbestos or plaster surface of any description over 10cm girth or width, not otherwise described including preparation of new surface & priming paints plaster coat complete
M & L for PCC 1:3:6 Type C2 using 40mm graded aggregate as in foundations, filling and mass concrete complete all as specified and as directed by the Engineer-in-Charge.
Removing building materials,rubbies etc to a distance of exc 1.0 km and nexc 5.00 km disposing off out side MD land including loading, unloading and stacking at the destination complete all as specified and as directed by EIC
M & L for preparation of old wall surfaces and applying one coat of colour wash complete all as specified and as directed.
Material and labour for applying two coats of 100% premium acrylic emulsion Paint camouflage pattern of approved design and colour having VOC less than 50gm/litre and UV resistance as per IS 15489-2004.Alkali&fungal resistance,dirt resistance exterior paint of required shade (company Depot tented) with silicon additives @ 1.43litre/10sqm weather proof emulsion paint over and including priming coat of exterior primer complete including removal of existing treatment and,filling minor cracks with necessary crack filler (DrFIXIT or Equivalent as approved) as per the manufacurer intructions complete all as specified and as directed by Engineer in charge.
S & F Punched type Concertina coil 600 mm dia with 9 horizontal reinforced barbed tape (RBT) tied with GI staples and GI clips to retain horizontal including necessary bolts or GI barbed wire tied to angle iron all complete as per direction of Engineer In Charge . RBT/ Spring core 2.50 mm thick wire of high tensile strength of 165 kg/sqmm with tape 0.52 mm thick of Supreme make or Equivalent and weight 43.478 gm/metre complete including taking down of old existing concertina coil of any description all as specified and as directed
MAYDINI CONSTRUCTION CO
SHIVAA CONSTRUCTIONS
RRK PROJECTS
Teleconcepts (India) Pvt Ltd
ARCHANA CONSTRUCTION CO
DHANUSH CONSTRUCTIONS CO.
Ravees Enterprises
GKR and CO
M/S Suresh Raju
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .