| Sl No | Description | Qty | Unit | GREENERGY SOLUTION PVT. LTD. L1 |
|---|---|---|---|---|
| 1.00Repair, Replacement & Servicing of VFDs and its subsystems for HVAC System at Nalanda Class Room Complex, IIT Kharagpur | ||||
| 1.01 | SITC of HVAC VFD Drive, Part Code FC-101P4K0T4E20H4XXCXXXSXXXXAXBXCXXXXDX
Serial Number-131L9866
VLT® HVAC Drive FC- 101
(P4K0) 4.0 KW / 5.0 HP, Three phase 380 - 480 VAC, (E20) IP20 / Chassis RFI C1 EMC filter with 50 meter motor cable,5% impedance DC choke on both positive and negative limbs, No Loc.Cont.Panel,3C3 Coated PCB,No mains Option,Operating temp upto 50 deg without deratings Frame: H2
Make-Danfoss or its Equivalent. | 14 | Nos. | 42,185 ₹5.9 L |
| 1.02 | SITC of HVAC VFD Drive,Part Code
FC-101P5K5T4E20H4XXCXXXSXXXXAXBXCXXXXDX
Serial Number-131L9867
VLT® HVAC Drive FC- 101
(P5K5) 5.5 KW / 7.5 HP, Three phase 380 - 480 VAC, (E20) IP20 / Chassis RFI C1 EMC filter with 50 meter motor cable,5% impedance DC choke on both positive and negative limbs, No Loc.Cont.Panel,3C3 Coated PCB,No mains Option,Operating temp upto 50 deg without deratings Frame: H3
Make-Danfoss or its Equivalent. | 2 | Nos. | 48,793 ₹97,586 |
| 1.03 | SITC of HVAC VFD Drive Part Code
FC-101P7K5T4E20H4XXCXXXSXXXXAXBXCXXXXDX
Serial Number-131L9868
VLT® HVAC Drive FC- 101
(P7K5) 7.5 KW / 10 HP, Three phase 380 - 480 VAC, (E20) IP20 / Chassis RFI C1 EMC filter with 50 meter motor cable,5% impedance DC choke on both positive and negative limbs,Loc.Cont.Panel,3C3 Coated PCB,No mains Option,Operating temp upto 50 deg without deratings Frame: H3
Make-Danfoss or its Equivalent. | 7 | Nos. | 54,870 ₹3.8 L |
| 1.04 | SITC of HVAC VFD Drive Part Code
FC-101P11KT4E20H4XXCXXXSXXXXAXBXCXXXXDX
Serial Number-131L9869
VLT® HVAC Drive FC- 101
(P11K) 11 KW / 15HP, Three phase 380 - 480 VAC, (E20) IP20 / Chassis,RFI C1 EMC filter with 50 meter motor cable,5% impedance DC choke on both positive and negative limbs,Loc.Cont.Panel,3C3 Coated PCB,No mains Option,Operating temp upto 50 deg without deratings Frame: H4
Make-Danfoss or its Equivalent. | 3 | Nos. | 71,036 ₹2.1 L |
| 1.05 | SITC of HVAC VFD Drive Part Code
FC-101P15KT4E20H4XXCXXXSXXXXAXBXCXXXXDX
Serial Number-131L9870
VLT® HVAC Drive FC- 101
(P15K) 15 KW / 20HP, Three phase 380 - 480 VAC, (E20) IP20 / Chassis,RFI C1 EMC filter with 50 meter motor cable,5% impedance DC choke on both positive and negative limbs,Loc.Cont.Panel,3C3 Coated PCB,No mains Option,Operating temp upto 50 deg without deratings Frame: H4
Make-Danfoss or its Equivalent. | 4 | Nos. | 81,420 ₹3.3 L |
| 1.06 | SITC of HVAC VFD Drive Part Code
FC-102P22KT4E20H1XGXXXXSXXXXAXBXCXXXXDX
Serial Number-131F6629
VLT® HVAC Drive FC- 102
(P22K) 22 KW / 30 HP, Three phase 380 - 480 VAC, (E20) IP20 / Chassis,RFI C1 EMC filter with 50 meter motor cable,5% impedance DC choke on both positive and negative limbs,Graphical Loc.Cont.Panel,Not Coated PCB,No mains Option,Operating temp upto 50 deg without deratings Frame: B4
Make-Danfoss or its Equivalent. | 1 | Nos. | 1,87,773 ₹1.9 L |
| 1.07 | SITC of HVAC VFD Drive Part Code
FC-102P11KT4E20H1XGXXXXSXXXXAXBXCXXXXDX
Serial Number-131F0427
VLT® HVAC Drive FC- 102
(P11K) 11 KW / 15 HP, Three phase 380 - 480 VAC, (E20) IP20 / Chassis,RFI C1 EMC filter with 50 meter motor cable,5% impedance DC choke on both positive and negative limbs,Graphical Loc.Cont.Panel,Not Coated PCB,No mains Option,Operating temp upto 50 deg without deratings Frame: B3
Make-Danfoss or its Equivalent. | 2 | Nos. | 1,07,521 ₹2.2 L |
| 1.08 | SITC of HVAC VFD Drive Part code
FC-102P15KT4E20H1XGXXXXSXXXXAXBXCXXXXDX
Serial Number-131F6631
VLT® HVAC Drive FC- 102
(P15K) 15 KW / 20 HP, Three phase 380 - 480 VAC, (E20) IP20 / Chassis,RFI C1 EMC filter with 50 meter motor cable,5% impedance DC choke on both positive and negative limbs,Graphical Loc.Cont.Panel,Not Coated PCB,No mains Option,Operating temp upto 50 deg without deratings Frame: B3
Make-Danfoss or its Equivalent. | 6 | Nos. | 1,29,387 ₹7.8 L |
| 1.09 | Servicing and Testing of existing 45 nos VFD drives for healthy operation | 1 | lot | 4,68,089 ₹4.7 L |
Updated dates
Tender Value
₹35.4 L
EMD Value
₹70,765
Closing Date
2 Dec 2025, 12:00 pmClosed
Superintending Engineer (E and M)
Office of Senior Executive Engineer (EW),1st Floor, Old Building, IIT Kharagpur, Kharagpur WB 721302
Repair, Replacement and Servicing of VFDs and its subsystems for HVAC System at Nalanda Class Room Complex, IIT Kharagpur
2025_IITKG_884445_1
IITKGP/IW/RAC/NCRC/VFD/2025
Open Tender
Electrical Works
90 days
Nalanda Class Room Complex of IIT Kharagpur
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹70,765
Meeting Room of SE(EandM)
29 Dec 2025
6 Nov 2025
3 Dec 2025
6 Nov 2025
2 Dec 2025
6 Nov 2025
13 Nov 2025
Amount
Repair, Replacement & Servicing of VFDs and its subsystems for HVAC System at Nalanda Class Room Complex, IIT Kharagpur
SITC of HVAC VFD Drive, Part Code FC-101P4K0T4E20H4XXCXXXSXXXXAXBXCXXXXDX Serial Number-131L9866 VLT® HVAC Drive FC- 101 (P4K0) 4.0 KW / 5.0 HP, Three phase 380 - 480 VAC, (E20) IP20 / Chassis RFI C1 EMC filter with 50 meter motor cable,5% impedance DC choke on both positive and negative limbs, No Loc.Cont.Panel,3C3 Coated PCB,No mains Option,Operating temp upto 50 deg without deratings Frame: H2 Make-Danfoss or its Equivalent.
SITC of HVAC VFD Drive,Part Code FC-101P5K5T4E20H4XXCXXXSXXXXAXBXCXXXXDX Serial Number-131L9867 VLT® HVAC Drive FC- 101 (P5K5) 5.5 KW / 7.5 HP, Three phase 380 - 480 VAC, (E20) IP20 / Chassis RFI C1 EMC filter with 50 meter motor cable,5% impedance DC choke on both positive and negative limbs, No Loc.Cont.Panel,3C3 Coated PCB,No mains Option,Operating temp upto 50 deg without deratings Frame: H3 Make-Danfoss or its Equivalent.
SITC of HVAC VFD Drive Part Code FC-101P7K5T4E20H4XXCXXXSXXXXAXBXCXXXXDX Serial Number-131L9868 VLT® HVAC Drive FC- 101 (P7K5) 7.5 KW / 10 HP, Three phase 380 - 480 VAC, (E20) IP20 / Chassis RFI C1 EMC filter with 50 meter motor cable,5% impedance DC choke on both positive and negative limbs,Loc.Cont.Panel,3C3 Coated PCB,No mains Option,Operating temp upto 50 deg without deratings Frame: H3 Make-Danfoss or its Equivalent.
SITC of HVAC VFD Drive Part Code FC-101P11KT4E20H4XXCXXXSXXXXAXBXCXXXXDX Serial Number-131L9869 VLT® HVAC Drive FC- 101 (P11K) 11 KW / 15HP, Three phase 380 - 480 VAC, (E20) IP20 / Chassis,RFI C1 EMC filter with 50 meter motor cable,5% impedance DC choke on both positive and negative limbs,Loc.Cont.Panel,3C3 Coated PCB,No mains Option,Operating temp upto 50 deg without deratings Frame: H4 Make-Danfoss or its Equivalent.
SITC of HVAC VFD Drive Part Code FC-101P15KT4E20H4XXCXXXSXXXXAXBXCXXXXDX Serial Number-131L9870 VLT® HVAC Drive FC- 101 (P15K) 15 KW / 20HP, Three phase 380 - 480 VAC, (E20) IP20 / Chassis,RFI C1 EMC filter with 50 meter motor cable,5% impedance DC choke on both positive and negative limbs,Loc.Cont.Panel,3C3 Coated PCB,No mains Option,Operating temp upto 50 deg without deratings Frame: H4 Make-Danfoss or its Equivalent.
SITC of HVAC VFD Drive Part Code FC-102P22KT4E20H1XGXXXXSXXXXAXBXCXXXXDX Serial Number-131F6629 VLT® HVAC Drive FC- 102 (P22K) 22 KW / 30 HP, Three phase 380 - 480 VAC, (E20) IP20 / Chassis,RFI C1 EMC filter with 50 meter motor cable,5% impedance DC choke on both positive and negative limbs,Graphical Loc.Cont.Panel,Not Coated PCB,No mains Option,Operating temp upto 50 deg without deratings Frame: B4 Make-Danfoss or its Equivalent.
SITC of HVAC VFD Drive Part Code FC-102P11KT4E20H1XGXXXXSXXXXAXBXCXXXXDX Serial Number-131F0427 VLT® HVAC Drive FC- 102 (P11K) 11 KW / 15 HP, Three phase 380 - 480 VAC, (E20) IP20 / Chassis,RFI C1 EMC filter with 50 meter motor cable,5% impedance DC choke on both positive and negative limbs,Graphical Loc.Cont.Panel,Not Coated PCB,No mains Option,Operating temp upto 50 deg without deratings Frame: B3 Make-Danfoss or its Equivalent.
SITC of HVAC VFD Drive Part code FC-102P15KT4E20H1XGXXXXSXXXXAXBXCXXXXDX Serial Number-131F6631 VLT® HVAC Drive FC- 102 (P15K) 15 KW / 20 HP, Three phase 380 - 480 VAC, (E20) IP20 / Chassis,RFI C1 EMC filter with 50 meter motor cable,5% impedance DC choke on both positive and negative limbs,Graphical Loc.Cont.Panel,Not Coated PCB,No mains Option,Operating temp upto 50 deg without deratings Frame: B3 Make-Danfoss or its Equivalent.
Servicing and Testing of existing 45 nos VFD drives for healthy operation
Panel Modification Works includes-Rewiring inside panel,ventilation implement in panel,repairing of panel door,earthing of panel etc.
stage.html