Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.2 LAccepted-AOC 620 DIAMOND HARBOUR RD BEHALA INDUSTRIAL ESTATE PLOT F 4 KOLKATA 700 034 | KOLKATA | KOLKATA | WEST BENGAL | 700034 | ₹2.2 L | L1 | Accepted-AOC L1 Bidder |
| 2 | L2₹4.5 L+₹2.3 L (108.3%)Rejected-Finance | ₹4.5 L+₹2.3 L (108.3%) | L2 | Rejected-Finance Towards L2 Bidder |
| 3 | L3₹5.0 L+₹2.8 L (128.8%)Rejected-Finance | ₹5.0 L+₹2.8 L (128.8%) | L3 | Rejected-Finance Towards L3 Bidder |
Tender Value
₹3.0 L
EMD Value
₹5,930
Closing Date
3 Apr 2024, 3:00 pmClosed
Administrative Officer, CSIR - IICB, Kolkata
CSIR-Indian Institute of Chemical Biology 4, Raja S. C. Mullick Road, Jadavpur, Kolkata-700032
Removal, Overhauling, Servicing and Re-installation of existing AC units
2024_CSIR_192322_1
ESD-E/146/2024-ENG-IICB
Open Tender
Miscellaneous Works
Item Rate
180 days
CSIR-IICB, Jadavpur Campus
As per NIT
4 documents required · 4 mandatory
₹0
₹5,930
Yes
29 Apr 2024
26 Mar 2024
4 Apr 2024
26 Mar 2024
3 Apr 2024
26 Mar 2024
Amount
Removal of Window type AC units (1.0/1.5 / 2.0 TR capacity): Removal of different makes & models Window type AC units from the specific location and keeping the dismantled AC units to store / place / location as indicated by the Engineer in charge within institute campus. This work is inclusive of making arrangement of covering / blocking open area with suitable size ply wooden board and nails (as applicable) as required to meet actual site requirement.
Removal of Split type AC units (1.0/1.5 / 2.0 TR capacity): Removal of different makes & models Split type AC units from the specific location and keeping the dismantled AC units to store / place / location as indicated by the Engineer in charge within institute campus. This work is inclusive pump down of Compressor for restore the refrigerant gas, removal of existing refrigerant pipe lines, drain line, bracket etc. and making arrangement of covering the holes for split AC pipe lines and blocking of pocket with white cement /putty or ply wooden board and nails (as applicable) as required to meet actual site requirement.
Re-installation of existing Split type AC Units (1.0/1.5 / 2.0 TR capacity): Standard complete Re-installation of existing Split type AC Units (different makes & models) for installation / shifting the same from one place to another place as indicated by the Engineer in charge / Lab in charge within the institute campus. This work is inclusive of all necessary work like Overhauling & Servicing (for existing AC units) , Laying & fixing of Copper pipes with insulation & Wrapping tape, Laying & fixing of Electric Wires & Drain Pipes, fixing of bracket, Leak testing, required Refrigerant Gas charging, necessary ply wooden board fixing & painting the same, covering the holes with white cement / putty if any etc. as required to meet actual site requirement for installation of AC units and run smooth functioning of the same .
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, wrapping tape, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : (Similar to Split type AC units works)
6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
Providing interconnected 1.1 KV, FRLS 4 Core x 2.5 Sq. mm Electric Wire (multi-strand) for Electrical connection of Indoor & Outdoor units of AC units
Providing suitable size heavy duty Bracket (steel material, L shape , powder coated finish) for fixing of outdoor unit of 1.5 / 2.0 ton capacity AC units.
Providing suitable size hard braided pipe (Dia-3/8", Colour- White / Blue ) for drain line of AC units
Providing suitable Refrigerant Gas (R-22 /33/410 or eco friendly) for different makes & models AC units
Providing Heavy duty Ply wooden Board (thickness 19 mm or above or equivalent) for installation of Split AC units
Providing of 15 Amps , 3 pin Plug Top for Electrical connection
Supply of universal AC remote Compatible with Most of The Brands Like Voltas, Carrier, Blue Star,Weather Makers, Electrolux, Hitachi, LG, Samsung, Whirlpool, Lloyd etc.
SUBARNA ENTERPRISE
AUTO-TECH PROJECTS PVT. LTD.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .