Mumbai Division Suburban Section - Repairing/ replacement of defective parts of Window AC & Split AC units of various makes & capacities at various locations between Marine Lines to Virar for 2 years.
EL-Maint-4-343-WA-8~WR
EL-Maint-4-343-WA-8
Open
Works - General
24 Months
Mumbai, Maharashtra
₹0
₹2.8 L
6 Oct 2026
28 Aug 2026
22 Sept 2026
81 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 1,37,95,190 | ||
| — | 4400.00 | — | — | ||
| Cleaning of filters, condenser coil, evaporator coil with compressed water /air blower, checking of working of AC unit, electrical connections etc; once in 06 months, as per specifications in Annexure I. | — | — | — | 8,66,800 | |
| — | 3600.00 | — | — | ||
| Cleaning of filters & evaporator coil with foam cleaner spray (3m, TetraClean, EcoCare, Pearl or any other ISI make brand) to remove dust, mold and odour buildup, cleaning of condenser coil with compressed water, checking of working of AC unit, electrical connections etc; once in 06 months, as per specifications in Annexure II. | — | — | — | 18,00,000 | |
| — | 40.00 | — | — | ||
| Replacement of defective rotary compressor by new rotary compressor of 1.5 TR capacity, as per specifications in Annexure III. | — | — | — | 4,34,800 | |
| — | 8.00 | — | — | ||
| Replacement of defective rotary compressor by new rotary compressor of 2.0 TR capacity, as per specifications in Annexure IV. | — | — | — | 1,03,296 | |
| — | 60.00 | — | — | ||
| Replacement of defective rotary inverter type compressor by new rotary inverter type compressor of 1.5 TR capacity, as per specifications in Annexure V. | — | — | — | 9,71,820 | |
| — | 720.00 | — | — | ||
| Supply of gas, flush the system with nitrogen, hold the system on pressure at 275 psi to detect leakage, repairing by brazing, vacuumizing and refrigerent gas charging of window AC - 1.5TR, and split AC 1.5 / 2.0 / 3.0 TR capacities, as per specifications in Annexure VI. | — | — | — | 19,04,400 | |
| — | 30.00 | — | — | ||
| Rewinding of defective condenser fan motor of window ACs, 1.5TR capacity, as per specifications in Annexure VII. | — | — | — | 39,630 | |
| — | 30.00 | — | — | ||
| Replacement of defective condenser fan motors of window ACs, 1.5TR capacity, as per specifications in Annexure VIII. | — | — | — | 73,080 | |
| — | 10.00 | — | — | ||
| Replacement of defective DC condenser fan motor of inverter type window AC, 1.5TR capacity, as per specifications in Annexure IX. | — | — | — | 22,820 | |
| — | 40.00 | — | — | ||
| Rewinding of defective condenser fan motor of split ACs, 1.5 /2.0 / 3.0TR capacity, as per specifications in Annexure X. | — | — | — | 50,040 | |
| — | 24.00 | — | — | ||
| Replacement of defective condenser fan motor of split ACs, 1.5 /2.0 / 3.0TR capacity, as per specifications in Annexure XI. | — | — | — | 60,072 | |
| — | 24.00 | — | — | ||
| Replacement of defective DC condenser fan motor for inverter type split AC 1.5/2.0/3.0 TR capacity, as per specifications in Annexure XII. | — | — | — | 76,680 | |
| — | 100.00 | — | — | ||
| Repairing of PCB circuit of window AC 1.5TR and split AC of 1.5 / 2.0 TR capacity non inverter type, as per specifications in Annexure XIII. | — | — | — | 1,25,100 | |
| — | 180.00 | — | — | ||
| Repairing of PCB circuit for window AC 1.5 TR & split AC of 1.5/2.0 TR capacity inverter type for indoor and outdoor units, as per specifications in Annexure XIV. | — | — | — | 6,57,540 | |
| — | 120.00 | — | — | ||
| Replacement of PCB circuit for window AC 1.5 TR & split AC of 1.5/2.0 TR capacity inverter type for indoor and outdoor units, as per specifications in Annexure XV. | — | — | — | 17,53,320 | |
| — | 20.00 | — | — | ||
| Replacement of indoor unit evaporator motor DC and non DC for split AC of 1.5 / 2.0 TR capacity, as per specifications in Annexure XVI. | — | — | — | 41,860 | |
| — | 240.00 | — | — | ||
| Replacement of capacitor P2 type 36/45/50 MFD or dual type 36/10, 45/6, 50/6 MFD, as per specifications in Annexure XVII. | — | — | — | 94,800 | |
| — | 150.00 | — | — | ||
| Replacement of capacitor P2 type 2.5 to 10 MFD; as per specifications in Annexure XVIII. | — | — | — | 24,600 | |
| — | 40.00 | — | — | ||
| Replacement of condenser fan blades for window ACs of 1.5TR and Split Acs of 1.5 / 2.0 / 3.0 TR capacities; as per specifications in Annexure XIX. | — | — | — | 50,040 | |
| — | 24.00 | — | — | ||
| Replacement of blower drum for window AC unit 1.5TR capacity, as per specifications in Annexure XX. | — | — | — | 30,024 | |
| — | 40.00 | — | — | ||
| Replacement of defective / aluminum condenser coil by new copper condenser coil for inverter and non-inverter type split AC units 1.5 TR capacity; as per specifications in Annexure XXI. | — | — | — | 2,37,160 | |
| — | 30.00 | — | — | ||
| Replacement of defective / aluminum condenser coil by new copper condenser coil for inverter and non-inverter type split AC units 2.0 TR capacity; as per specifications in Annexure XXII. | — | — | — | 1,97,640 | |
| — | 10.00 | — | — | ||
| Replacement of defective / aluminum condenser coil by new copper condenser coil for inverter and non-inverter type window AC units 1.5 TR capacity; as per specifications in Annexure XXIII. | — | — | — | 59,290 | |
| — | 200.00 | — | — | ||
| Replacement of internal wiring of AC units, by new copper wire with lugs, PVC insulated unsheathed FRLS copper wire flexible multi- strand, of size 1.5 / 2.5 mm², single core; as per specifications in Annexure XXIV. | — | — | — | 26,200 | |
| — | 780.00 | — | — | ||
| Removal of old cable and, supply, fixing, testing and commissioning of PVC insulated & sheathed copper cable flexible multi-strand, 1100 Volt grade, FRLS, confirming to IS: 694 of 2010 or latest / IEC / NEC / NFPA Standards, ISI marked of reputed make, for interconnection to indoor and outdoor unit. The connection shall be made with suitable bi-metallic crimping sockets of proper size & rating. The cable shall be fixed with proper workmanship. Cable size: 2.5 sq.mm., 4 core. | — | — | — | 1,17,780 | |
| — | 24.00 | — | — | ||
| Supply and installation of contactor for spilt AC unit. Scope of work covers:• Remove the defective contactor and replace it by new contactor of same size, shape, capacity, specifications and other parameters that of the existing.• Released contactor shall be handed over to Railway Supervisor. | — | — | — | 10,968 | |
| — | 5.00 | — | — | ||
| Supply and installation of Discharge Grill Assembly (Tray for drain water) for Inverter type Split AC unit; as per specifications in Annex XXV. | — | — | — | 8,480 | |
| — | 160.00 | — | — | ||
| Installation, testing & commissioning of split AC units of capacity 1.5 TR/2.0 TR at the nominated site complete with all accessories, as per specifications in Annexure XXVI. | — | — | — | 2,22,720 | |
| — | 1400.00 | — | — | ||
| Supply and fixing of refrigerant copper tubing with insulation of required size, copper pipe dia 5/8" or 3/8" or 1/2" as per site requirement, complete with hardware fittings, as per specifications in Annexure XXVII. | — | — | — | 6,94,400 | |
| — | 1400.00 | — | — | ||
| Supply and fixing of refrigerant copper tubing with insulation of required size, copper pipe dia 1/4", complete with hardware fittings as per specifications in Annexure XXVII. | — | — | — | 3,83,600 | |
| — | 220.00 | — | — | ||
| Supply and fixing of drainage CPVC pipe line of plumbing grade conforming to Standard - IS 15778, Class-SDR 11, ISI marked, with threaded type accessories.Nominal bore size - 25 mm, thickness - 2.6 mm minimum with tolerance 0.51 mm or Nominal bore size - 40 mm, thickness - 3.8 mm minimum with tolerance 0.51 mm. Size of the pipe shall be decided by the SSE as per site requirement. PVC pipe line shall be fixed by PVC/G I saddling with proper slope so as to drain out the condensate water easily. Drainage pipe line should be terminated at the nearest drain. The work shall be done with proper workmanship. (Qty Unit - RM = (Running Meter) | — | — | — | 18,700 | |
| — | 160.00 | — | — | ||
| Supply & fixing of bracket type ms stands to erect the condensing unit of split AC. The stands should be adjustable type & suitable to fix on wall with required hardware & accessories. The bracket type stands used should be with adjustable holes on vertical strip to adjust the height of condensing unit as per site condition and fixing with suitable size GI fasteners /GI nut bolts etc., as per site requirement. | — | — | — | 2,51,680 | |
| — | 300.00 | — | — | ||
| Supply of labour with transportation and removing, shifting of AC units from one location / station to another location / station, as per scope of work in Annexure XXVIII. | — | — | — | 2,73,300 | |
| — | 80.00 | — | — | ||
| Supply & fixing of Air shield PVC air conditioner line set cover kit advanced, max. 13 feet length for split AC, white colour model no. AS-1 or equivalent, having end cap, casing pipe max. 13 feet, connectors, movable L shape elbow, wall hole cover and flexible pipe etc. including the labour charges for fixing. The cover kit to provide essential protection for the refrigerant lines and electrical wiring. | — | — | — | 5,60,000 | |
| — | 4000.00 | — | — | ||
| Fabrication, supply & fixing of M.S. structure for installation and maintenance of outdoor units, as per scope of work in Annexure XXIX. | — | — | — | 9,20,000 | |
| — | 40.00 | — | — | ||
| Provision of core cutting of appropriate size in the walls for routing the AC accessories from the indoor unit to the outdoor units. | — | — | — | 80,000 | |
| — | 200.00 | — | — | ||
| Provision of groove for copper pipes, drain pipes & cable for AC units, approx. size 2 inch deep x 3 inch height for fixing and concealing of all AC accessories like liquid and suction copper pipes, cable and drain pipes along with final layer of white cement for covering the groove. After providing concealing all ac accessories the surface of wall/ceiling shall be made as earlier by providing cement plaster, POP/ white putti and painting. (Qty Unit - RM = (Running Meter) | — | — | — | 44,000 | |
| — | 150.00 | — | — | ||
| Supply and installation of GI perforated cable tray of size 150mm width x 50mm depth x 1.6mm thick, powder coated with RED colour, including horizontal and vertical reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with GI suspenders etc. as required, as per specifications in Annexure XXX. | — | — | — | 68,550 | |
| — | 16.00 | — | — | ||
| Provision of 4.0 TR verticool system on rent basis for a period of one day per AC at the location required complete with all accessories and also, dismantling and removing the Tower AC from the site as per scope of work in Annexure XXXI. | — | — | — | 3,20,000 | |
| — | 20.00 | — | — | ||
| Providing temprorary jhula/scaffolding arrangement and fixing of copper piping/ ducting/drain piping/outdoor unit, as per scope of work in Annexure XXXII. | — | — | — | 1,20,000 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCC-April-2022.pdf
ATTACHMENT
GCCCorrectionSlipNo1ofACS-14-07-2022.pdf
ATTACHMENT
GCCApril2022CorrectionslipNo_2RBDtd13122022.pdf
ATTACHMENT
IRSGCC-2022-AdvanceCorrectionSlipNo.3.pdf
ATTACHMENT
GCCApril2022ACSlip4.pdf
ATTACHMENT
GCCApril-2022AdvanceCorrectionSlipNo_5.pdf
ATTACHMENT
2026_03_13IndianRailwaysStandardGeneralConditionsofContractApril2022AdvanceCorrectionSlipNo_111.pdf Advance Correction Slip No 11
ATTACHMENT
AnnexureVclarificationforonlinesubmissiondated14.05.2024.pdf
ATTACHMENT
AnnexureVIBAnnualContractualTurnoverGCC2022.pdf
ATTACHMENT
BidSecurityFormat.pdf
ATTACHMENT
BankGuaranteeFormat.pdf
ATTACHMENT
InsuranceSuretyBondforPerformanceSecurity.pdf
ATTACHMENT
NoRelativeFormatEmployeeofWesternRailway-Annexure-II.pdf
ATTACHMENT
NORETIREDRAILWAYEMPLOYEEGCC2022-Annexure-III.pdf
ATTACHMENT
EL-Maint-4-343-WA-82026-2027.pdf
ATTACHMENT
EL-Maint-4-343-WA-8CorrigendumDocument.pdf
ATTACHMENT
EL-Maint-4-343-WA-82026-2027Corrigendum.pdf
ATTACHMENT
2026_03_13IndianRailwaysStandardGeneralConditionsofContractApril2022AdvanceCorrectionSlipNo_111.pdf
ATTACHMENT
EL-Maint-4-343-WA-8CorrigendumDocument.pdf
CORRIGENDUM
EL-Maint-4-343-WA-82026-2027Corrigendum.pdf
CORRIGENDUM
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .