Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 5 66 THIRD FLOOR K C HOUSE PADAM SINGH ROAD W E A KAROL BAGH CENTRAL DELHI DELHI 110005 | CENTRAL DELHI | DELHI | 110005 | Admitted-Finance |
| 2 | Admitted-Finance KHASRA NO 388 KHATA NO 113 PARSON DASNA DHAULANA HAPUR PARGANA DASNA NEAR NH 24 HIGHWAY VILLAGE PARSON TEHSIL DHAULANA DASNA HAPUR UTTAR PRADESH 201015 | GHAZIABAD | UTTAR PRADESH | 201015 | Admitted-Finance |
| 3 | Rejected-Technical 94 1ST FLOOR SHAMBHU DAYAL BAGH MARG NEAR OKHLA INDL AREA PHASE III OLD ISHWAR NAGAR NEW DELHI DELHI 110020 | SOUTH EAST DELHI | DELHI | 110020 | Rejected-Technical NOT ACCEPTABLE |
| 4 | Rejected-Technical 4801 BHARAT RAM ROAD 24 DARYAGANJ DELHI CENTRAL DELHI DELHI 110002 | CENTRAL DELHI | DELHI | 110002 | Rejected-Technical NOT ACCEPTABLE |
| 5 | Rejected-Technical D 90 OKHLA INDUSTRIAL AREA PHASE 1 NEW DELHI NEW DELHI DELHI 110020 | SOUTH EAST DELHI | DELHI | 110020 | Rejected-Technical NOT ACCEPTABLE |
Tender Value
Refer Docs
Closing Date
12 Jan 2024, 3:00 pmClosed
Sekar Hirudhayam
TECHNIP ENERGIES INDIA LTD, CHENNAI
INSTRUMENTATION THERMOCOUPLE AND EARTHING CABLES LOT 1 FOR NUMALIGARH REFINERY EXPANSION PROJECT
2023_NRL_781178_2
TP/082176C/NRL/PQ/123
Limited
Electrical Goods/Equipment
Supply
180 days
NUMALIGARH
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
Exempted
7 Jun 2024
21 Dec 2023
13 Jan 2024
21 Dec 2023
12 Jan 2024
3 Jan 2024
LOT 1 - FLAME RETARDANT ARMOURED SIGNAL CABLES - IS Cable for Instrument, Annealed Bare Copper, XLPE Insulation, Al-mylar Collective Shielded with ATC drain wire, Flame Retardant Low Smoke, ST2 PVC sheathed, Galvanised Steel wire flat armoured, Intrinsic safe as per MR. Note:The Quantity given under 'Column 'D' is sum of quantity of Cables as per MR and Mandatory Spares Cables (5%) NRL MSL Category : 6.210 INSTRUMENT SIGNAL CABLE
12Px2.5 IS Blue Flame Retd. LS PVC Arm Ovl shld Cable Code :E5-0.6/1.1-TTCOCO(C)-2.5(12P)IB Cable Type:TYPE S31
1Px2.5 IS Blue Flame Retd. LS PVC Arm Ovl shld Cable Code: E5-0.6/1.1-TTCOCO(C)-2.5(1P)IB Cable Type:TYPE S3
6Px2.5 IS Blue Flame Retd. LS PVC Arm Ovl shld Cable code:E5-0.6/1.1-TTCOCO(C)-2.5(6P)IB Cable Type:TYPE S21
1Px4 IS Blue Flame Retd. LS PVC Arm Ovl shld Cable Code:E5-0.6/1.1-TTCOCO(C)-4(1P)IB Cable Type:TYPE S85
2Px4 IS Blue Flame Retd. LS PVC Arm Ind+Ovl shld Cable Code:E5-0.6/1.1-TTCOCO(I/C)-4(2P)IB Cable Type:TYPE S86
6Px1.5 IS Blue Flame Retd. LS PVC Arm Ind+Ovl shld Cable Code:E5-0.6/1.1-TTCOCO(I/C)-1.5(6P)IB Cable Type:TYPE S17
12Px2.5 IS Blue Flame Retd. LS PVC Arm Ind+Ovl shld Cable Code:E5-0.6/1.1-TTCOCO(I/C)-2.5(12P)IB Cable Type:TYPE S93
2Px2.5 IS Blue Flame Retd. LS PVC Arm Ind+Ovl shld Cable Code:E5-0.6/1.1-TTCOCO(I/C)-2.5(2P)IB Cable Type:TYPE S96
6Px2.5 IS Blue Flame Retd. LS PVC Arm Ind+Ovl shld Cable Code:E5-0.6/1.1-TTCOCO(I/C)-2.5(6P)IB Cable Type:TYPE S97
1Px1.5 IS Blue Flame Retd. LS PVC Arm Ovl shld Cable code:E5-0.6/1.1-TTCOCO(C)-1.5(1P)IB Cable Type:TYPE S1
12Px1.5 IS Blue Flame Retd. LS PVC Arm Ind+Ovl shld Cable code:E5-0.6/1.1-TTCOCO(I/C)-1.5(12P)IB Cable Type:Type S27
LOT-2 - FLAME RETARDANT ARMOURED SIGNAL CABLES - NIS Cable for Instrument, Annealed Bare Copper, XLPE Insulation, Al-mylar Collective Shielded with ATC drain wire, Flame Retardant Low Smoke, ST2 PVC sheathed, Galvanised Steel wire flat armoured, Non-Intrinsic safe as per MR. Note:The Quantity given under 'Column 'D' is sum of quantity of Cables as per MR and Mandatory Spares Cables (5%) NRL MSL Category - 6.210 INSTRUMENT SIGNAL CABLE
1Px2.5 NIS Black Flame Retd. LS PVC Arm Ovl shld Cable code:E5-0.6/1.1-TTCOCO(C)-2.5(1P)NK Cable Type:TYPE S4
2Px1.5 NIS Black Flame Retd. LS PVC Arm Ind+Ovl shld Cable code:E5-0.6/1.1-TTCOCO(I/C)-1.5(2P)NK Cable Type:TYPE S11
6Px1.5 NIS Black Flame Retd. LS PVC Arm Ind+Ovl shld Cable code:E5-0.6/1.1-TTCOCO(I/C)-1.5(6P)NK Cable Type:TYPE S18
12Px2.5 NIS Black Flame Retd. LS PVC Arm Ind+Ovl shld Cable code:E5-0.6/1.1-TTCOCO(I/C)-2.5(12P)NK Cable Type:TYPE S30
2Px2.5 NIS Black Flame Retd. LS PVC Arm Ind+Ovl shld Cable Code:E5-0.6/1.1-TTCOCO(I/C)-2.5(2P)NK Cable Type:TYPE S14
6Px2.5 NIS Black Flame Retd. LS PVC Arm Ind+Ovl shld Cable Code:E5-0.6/1.1-TTCOCO(I/C)-2.5(6P)NK Cable Type:TYPE S20
8Tx2.5 NIS Black Flame Retd. LS PVC Arm Ind+Ovl shld Cable Code:E5-0.6/1.1-TTCOCO(I/C)-2.5(8T)NK Cable Type:TYPE S95
1Px1.5 NIS Black Flame Retd. LS PVC Arm Ovl shld Cable Code:E5-0.6/1.1-TTCOCO(C)-1.5(1P)NK Cable Type:TYPE S2
12Px1.5 NIS Black Flame Retd. LS PVC Arm Ind+Ovl shld Cable Code:E5-0.6/1.1-TTCOCO(I/C)-1.5(12P)NK Cable Type:TYPE S28
LOT-3 - FIRE RESISTANT ARMOURED SIGNAL CABLES - IS Cable for Instrument, Annealed Bare Copper, XLPE Insulation, Al-mylar Collective Shielded with ATC drain wire, Fire resistant Low Smoke Zero Halogen, ST2 PVC sheathed, Galvanised Steel wire flat armoured, Intrinsic safe as per MR. Note:The Quantity given under 'Column 'D' is sum of quantity of Cables as per MR and Mandatory Spares Cables (5%) NRL MSL Category - 6.212 SIGNAL CABLE- FIRE RESISTENT
1Px1.5 IS Red+Blue Strip Fire Rest. LSZH Arm Ovl shld Cable Code:E4-0.6/1.1-TTCXCX(C)-1.5(1P)IRB Cable Type:TYPE S43
12Px2.5 IS Red+Blue Strip Fire Rest. LSZH Arm Ovl shld Cable Code:E4-0.6/1.1-TTCXCX(C)-2.5(12P)IRB Cable Type:TYPE S71
1Px2.5 IS Red+Blue Strip Fire Rest. LSZH Arm Ovl shld Cable Code:E4-0.6/1.1-TTCXCX(C)-2.5(1P)IRB Cable Type:TYPE S45
6Px2.5 IS Red+Blue Strip Fire Rest. LSZH Arm Ovl shld Cable Code:E4-0.6/1.1-TTCXCX(C)-2.5(6P)IRB Cable Type:TYPE S61
12Px1.5 IS Red+Blue Strip Fire Rest. LSZH Arm Ind+Ovl shld Cable Code:E4-0.6/1.1-TTCXCX(I/C)-1.5(12P)IRB Cable Type:TYPE S67
6Px1.5 IS Red+Blue Strip Fire Rest. LSZH Arm Ind+Ovl shld Cable Code:E4-0.6/1.1-TTCXCX(I/C)-1.5(6P)IRB Cable Type:TYPE S57
12Px2.5 IS Red+Blue Strip Fire Rest. LSZH Arm Ind+Ovl shld Cable Code:E4-0.6/1.1-TTCXCX(I/C)-2.5(12P)IRB Cable Type:TYPE S94
2Px2.5 IS Red+Blue Strip Fire Rest. LSZH Arm Ovl shld Cable Code:E4-0.6/1.1-TTCXCX(C)-2.5(2P)IRB Cable Type:TYPE S55
LOT-4 - FIRE RESISTANT UNARMOURED SIGNAL CABLES - IS Cable for Instrument, Annealed Bare Copper, XLPE Insulation, Al-mylar Collective Shielded with ATC drain wire, Fire resistant Low Smoke Zero Halogen, ST2 PVC sheathed, Unarmoured, Intrinsic safe as per MR. Note:The Quantity given under 'Column 'D' is sum of quantity of Cables as per MR and Mandatory Spares Cables (5%) NRL MSL Category - 6.212 SIGNAL CABLE- FIRE RESISTENT
1Px1.5 IS Red+Blue Strip Fire Rest. LSZH UArm Ovl shld Cable Code:E4-0.6/1.1-TTCXX(C)-1.5(1P)IRB Cable Type: TYPE S80
LOT-5 - FIRE RESISTANT ARMOURED SIGNAL CABLES - NIS Cable for Instrument, Annealed Bare Copper, XLPE Insulation, Al-mylar Collective Shielded with ATC drain wire, Fire resistant Low Smoke Zero Halogen, ST2 PVC sheathed, Galvanised Steel wire flat armoured, Non Intrinsic safe as per MR. Note:The Quantity given under 'Column 'D' is sum of quantity of Cables as per MR and Mandatory Spares Cables (5%) NRL MSL Category - 6.212 SIGNAL CABLE- FIRE RESISTENT
1Px1.5 NIS Red Fire Rest. LSZH Arm Ovl shld Cable Code:E4-0.6/1.1-TTCXCX(C)-1.5(1P)NR Cable Type: TYPE S44
1Tx1.5 NIS Red Fire Rest. LSZH Arm Ovl shld Cable Code:E4-0.6/1.1-TTCXCX(C)-1.5(1T)NR Cable Type: TYPE S48
1Px2.5 NIS Red Fire Rest. LSZH Arm Ovl shld Cable Code:E4-0.6/1.1-TTCXCX(C)-2.5(1P)NR Cable Type:TYPE S46
1Tx2.5 NIS Red Fire Rest. LSZH Arm Ovl shld Cable Code: E4-0.6/1.1-TTCXCX(C)-2.5(1T)NR Cable Type:TYPE S91
1Px4 NIS Red Fire Rest. LSZH Arm Ovl shld Cable Code:E4-0.6/1.1-TTCXCX(C)-4(1P)NR Cable Type:TYPE S87
12Px1.5 NIS Red Fire Rest. LSZH Arm Ind+Ovl shld Cable Code:E4-0.6/1.1-TTCXCX(I/C)-1.5(12P)NR Cable Type:TYPE S68
2Px1.5 NIS Red Fire Rest. LSZH Arm Ind+Ovl shld Cable Code:E4-0.6/1.1-TTCXCX(I/C)-1.5(2P)NR Cable Type:TYPE S52
6Px1.5 NIS Red Fire Rest. LSZH Arm Ind+Ovl shld Cable Code:E4-0.6/1.1-TTCXCX(I/C)-1.5(6P)NR Cable Type:TYPE S58
6Tx1.5 NIS Red Fire Rest. LSZH Arm Ind+Ovl shld Cable Code:E4-0.6/1.1-TTCXCX(I/C)-1.5(6T)NR Cable Type:TYPE S64
8Tx1.5 NIS Red Fire Rest. LSZH Arm Ind+Ovl shld Cable Code:E4-0.6/1.1-TTCXCX(I/C)-1.5(8T)NR Cable Type:TYPE S74
12Px2.5 NIS Red Fire Rest. LSZH Arm Ind+Ovl shld Cable Code:E4-0.6/1.1-TTCXCX(I/C)-2.5(12P)NR Cable Type: TYPE S70
6Px2.5 NIS Red Fire Rest. LSZH Arm Ind+Ovl shld Cable Code:E4-0.6/1.1-TTCXCX(I/C)-2.5(6P)NR Cable Type:TYPE S60
6Tx2.5 NIS Red Fire Rest. LSZH Arm Ind+Ovl shld Cable Code:E4-0.6/1.1-TTCXCX(I/C)-2.5(6T)NR Cable Type:TYPE S98
12Px4 NIS Red Fire Rest. LSZH Arm Ind+Ovl shld Cable Code:E4-0.6/1.1-TTCXCX(I/C)-4(12P)NR Cable Type:TYPE S90
8Tx2.5 NIS Red Fire Rest. LSZH Arm Ind+Ovl shld Cable Code:E4-0.6/1.1-TTCXCX(I/C)-2.5(8T)NR Cable Type:TYPE S99
LOT-6 - FIRE RESISTANT UNARMOURED SIGNAL CABLES – NIS Cable for Instrument, Annealed Bare Copper, XLPE Insulation, Al-mylar Collective Shielded with ATC drain wire, Fire resistant Low Smoke Zero Halogen, ST2 PVC sheathed, Unarmoured, Non Intrinsic safe as per MR. Note:The Quantity given under 'Column 'D' is sum of quantity of Cables as per MR and Mandatory Spares Cables (5%) NRL MSL Category - 6.212 SIGNAL CABLE- FIRE RESISTENT
1Px1.5 NIS Red Fire Rest. LSZH UArm Ovl shld Cable Code:E4-0.6/1.1-TTCXX(C)-1.5(1P)NR Cable Type:TYPE S81
1Px2.5 NIS Red Fire Rest. LSZH UArm Ovl shld Cable Code:E4-0.6/1.1-TTCXX(C)-2.5(1P)NR Cable Type:TYPE S82
12Px1.5 NIS Red Fire Rest. LSZH UArm Ind+Ovl shld Cable Code:E4-0.6/1.1-TTCXX(I/C)-1.5(12P)NR Cable Type:TYPE S83
2Px1.5 NIS Red Fire Rest. LSZH UArm Ind+Ovl shld Cable Code:E4-0.6/1.1-TTCXX(I/C)-1.5(2P)NR Cable Type: TYPE S84
6Px1.5 NIS Red Fire Rest. LSZH UArm Ind+Ovl shld Cable Code:E4-0.6/1.1-TTCXX(I/C)-1.5(6P)NR Cable Type:TYPE S79
LOT-7 - FLAME RETARDANT THERMOCUPLE CABLE (K-TYPE) Cable for Instrument, Annealed Bare Copper, XLPE Insulation, Al-mylar Collective Shielded with ATC drain wire, Flame retardant Low Smoke Low Halogen, ST2 PVC sheathed, Galvanised Steel wire flat armoured as per MR. Note:The Quantity given under 'Column 'D' is sum of quantity of Cables as per MR and Mandatory Spares Cables (5%) NRL MSL Category - 6.213 - INSTRUMENT THERMOCOUPLE CABLE
1Px16AWG Yellow Flame Retd. LS PVC Arm Ovl shld T/C-K Cable Code:X4-0.6/1.1-TTCOCO(C)-16(1P)Y Cable Type: TYPE S37
LOT-8 - FLAME RETARDANT EARTHING CABLE Cable for Instrument, Annealed Bare Copper, XLPE Insulation, Al-mylar Collective Shielded with ATC drain wire, Flame retardant Low Smoke Low Halogen, ST2 PVC sheathed, Unarmoured as per MR. Note:The Quantity given under 'Column 'D' is sum of quantity of Cables as per MR and Mandatory Spares Cables (5%) NRL MSL Category - 6.210 INSTRUMENT SIGNAL CABLE
1Cx6 Green+Blue Strip Flame Retd. LS PVC Unarm Cable Code:E5-0.6/1.1-SC-6(1C)GB Cable Type:TYPE E1
1Cx6 Green+ Yellow Strip Flame Retd. LS PVC Unarm Cable Code:E5-0.6/1.1-SC-6(1C)GY Cable Type:TYPE E2
1Cx6 Green Flame Retd. LS PVC Unarm Cable Code:E5-0.6/1.1-SC-6(1C)G Cable Type:TYPE E3
1Cx2.5 Green+ Yellow+ Green Strip Flame Retd. LS PVC Unarm Cable Code:E5-0.6/1.1-SC-2.5(1C)GYG Cable Type:TYPE E6
1Cx10 Green+ Yellow +Green Strip Flame Retd. LS PVC Unarm Cable Code:E5-0.6/1.1-SC-10(1C)GYG Cable Type:TYPE E7
M/S ELKAY TELELINKS LIMITED
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .