Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical | Accepted-Technical Accepted |
| 2 | Accepted-Technical 90 MYLAPORE CHENNAI TAMIL NADU 600004 | CHENNAI | TAMIL NADU | 600004 | Accepted-Technical Accepted |
| 3 | Accepted-Technical | Accepted-Technical Accepted |
Tender Value
₹31.6 L
EMD Value
₹63,120
Closing Date
5 May 2026, 3:00 pmClosed
Superintending Engineer, ACVSD, ESG
Superintending Engineer, ACVSD, ESG, IGCAR
Fabrication and erection of AC ducts other associated works at IGCAR, Kalpakkam for the year 2026 2027
2026_IGCAR_905579_1
IGCAR/ESG/ACVSD/ACMS/T282/2026
Open Tender
Machineries/ Mechanical Engg Items
Item Rate
365 days
IGCAR, Kalpakkam
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹63,120
23 Jul 2026
16 Apr 2026
6 May 2026
16 Apr 2026
5 May 2026
21 Apr 2026
16 Apr 2026 - 20 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supply, fabrication and erection of GI ducting including providing of vanes, M.S angle support, angle flanges, anchor fasteners, grill collar, tees, bends, etc. as per the scope of work. | |||||
| 1.1 | 22 gauge Class VIII G.I sheet | 300 | m2 | - | - |
| 1.2 | 20gauge Class VIII G.I sheet | 150 | m2 | - | - |
| 1.3 | 18 gauge Class VIII G.I sheet | 50 | m2 | - | - |
| 2Supply and installation of Thermal insulation of above ducting (item-4) with closed cell Nitryle foam rubber/cross linked polyethylene thermal insulation. The insulation shall be covered with aluminium foil of 40G thick and fixed properly by self adhesive aluminium tape as per the scope of work. | |||||
| 2.1 | 9 mm thick | 150 | m2 | - | - |
| 2.2 | 13 mm thick | 150 | m2 | - | - |
| 3 | Supply and installation of 19 mm thick Fibre free and antimicrobial resistant, Open cell elastomeric nitrile rubber acoustic insulation in supply air ducts with fire retared "O" class, fire performance, resistant to chemical & micro organism and sound absorption class-D as per the technical specification and scope of work enclosed. | 200 | m2 | - | - |
| 4 | Supply and installation of vertically opposed blade Volume Control Damper. The damper shall be made of extruded anodized aluminium, powder coated aliminium volume control damper having vertical louvers as per the specification. | 4 | m2 | - | - |
| 5 | Supply and installation of Fire Damper which shall be provided at the supply duct and suction side of AC plant room. Fire dampers shall be provided with approved make fire and smoke of at least 90 min. fire rating certified by CBRI Roorkee as per UL 555: 1973 or Indian equivalent standards. | 2 | m2 | - | - |
stage.html
html • 0.02 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 4.00 MB
Tendernotice_2.pdf
PDF • 1.30 MB
BOQ_951857.xls
BOQ • 0.30 MB
TenderdocT282.pdf
Tender Documents • 1.28 MB
CLRAFORM.pdf
Additional Documents • 8.56 MB
Corrigendum.pdf
PDF • 0.23 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .