Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.0 CrAccepted-AOC 216 UGF RAM VIHAR ANAND VIHAR DELHI 110092 | SHAHDARA | DELHI | 110092 | ₹1.0 Cr | L1 | Accepted-AOC BEING L1 |
| 2 | L2₹1.1 Cr+₹8.5 L (8.42%)Rejected-Finance | ₹1.1 Cr+₹8.5 L (8.42%) | L2 | Rejected-Finance OTHER THAN L1 |
| 3 | L3₹1.1 Cr+₹12.2 L (12.2%)Rejected-Finance | ₹1.1 Cr+₹12.2 L (12.2%) | L3 | Rejected-Finance OTHER THAN L1 |
| 4 | L4₹1.2 Cr+₹15.7 L (15.6%)Rejected-Finance B 101 3RD FLOOR JHILMI COLONY DELHI 110095 | DELHI | EAST DELHI | DELHI | 110095 | ₹1.2 Cr+₹15.7 L (15.6%) | L4 | Rejected-Finance OTHER THAN L1 |
| 5 | L5₹1.3 Cr+₹30.7 L (30.6%)Rejected-Finance RZ 31 222 J BLOCK WEST SAGARPUR NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | ₹1.3 Cr+₹30.7 L (30.6%) | L5 | Rejected-Finance OTHER THAN L1 |
| Sl No | Description | Qty | Unit | BEHAL TRADERS L4 | V M CONSTRUCTION L1 | Parveen Builders L3 | Chaudhary Constructions L6 | tarun construction co L2 | M/S Chhavi Constructions Co L5 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | M & L for Dismantling of brick tiles (laid flat or on edge) on roof surface.laid bedded and pointed in any mortar | 590 | Sqm | 20 ₹11,800 | 15 ₹8,850 Lowest | 20 ₹11,800 | 35 ₹20,650 | 15 ₹8,850 Lowest | 19 ₹11,210 |
| 2.00 | M & L for Demolition of mud in roof, any thickness, including plastering and leeping upto two storey bldg incl necessary scaffolding arrangement complete all as specified and directed(whether full thickness removed or only a part there of) and removing from cantonment area or as directed complete all as directed by Engr in charge and specified. | 118 | Cum | 200 ₹23,600 | 200 ₹23,600 | 250 ₹29,500 | 555 ₹65,490 | 190 ₹22,420 Lowest | 500 ₹59,000 |
| 3.00 | M&L surface to be cleaned properly with wire brush to remove dust/loose particles from the surface. All the cracks should be opened in V groove and sealed properly with polyurethane sealant or polymer modified mortar. The surface should be oil and dirt free & in case of any unsound surface replastering to be done properly after application of SBR bonding coat. unsound horizontal surfaces to be filled with free-flowing micro concrete. | 590 | Sqm | 150 ₹88,500 | 250 ₹1,47,500 | 20 ₹11,800 Lowest | 45 ₹26,550 | 70 ₹41,300 | 200 ₹1,18,000 |
| 4.00 | M&L for Cement concrete type B-0, 1:2:4 (12.5mm graded aggregate) as in roof pedding , finished even and smooth without using extra cement ,including cleaning the concrete surface by steel wire brushes, up to three stories bldgs, complete . | 29.5 | Cum | 3,800 ₹1,12,100 Lowest | 5,000 ₹1,47,500 | 5,500 ₹1,62,250 | 5,000 ₹1,47,500 | 4,900 ₹1,44,550 | 6,500 ₹1,91,750 |
| 5.00 | M&L single component Solvent based moisture cured polyurethane resin based low viscous highly penetrative primer to be mixed properly with electric mixture and to be applied by brush/roller over the entire surface. The deposition of primer should be minimum 200ml/Sq.mt however the same can be varied based upon surface porosity. | 590 | Sqm | 250 ₹1,47,500 | 600 ₹3,54,000 | 300 ₹1,77,000 | 130 ₹76,700 Lowest | 195 ₹1,15,050 | 150 ₹88,500 |
| 6.00 | M&L Two coats of Single component non-UV resistant based polyurethane to be applied over the primed surface in an interval of 4-6 hrs. The topcoats should be applied with brush/ roller. No dilution is required for these two coats. A non-woven geotextile sheet of 60 GSM to be sandwiched between the layers. The deposition of PU should be 1.8 kg per Sq.mt providing avg thickness of 1.2 mm. The tensile strength of the product should be minimum 1.8 N/mm2. The elongation of the free film should be min 650% as per ASTM D412, Shore A Hardness should be min 45 as per ASTM D-2240, Crack Bridging @-9degree C min 1.5 as per ASTM C 836 & Solid Content should not be less than 90%. Moreover, the material should confirm to ASTM C-836, ASTM C-898. | 590 | Sqm | 800 ₹4,72,000 | 750 ₹4,42,500 Lowest | 900 ₹5,31,000 | 900 ₹5,31,000 | 790 ₹4,66,100 | 1,200 ₹7,08,000 |
| 7.00 | M&L providing and applying roof insulation with Polyurethane Spray Foam, a two-component system. Polyol and Isocyanate are used in combination to produce rigid low density polyurethane spray foam. It gives good thermal insulation with 80 mm thick impervious sprayed, closed cell free Rigid Polyurethane foam - PU Spray PUF over deck insulation conforming to IS-12432 Pt. III (density of foam being 45-50 kg/ cum). The surface on which spray is applied to be cleaned properly, the moisture content in the surface shall be less than 5% and is to be dried before the application of spray, Polyurethane chemical (A side and B side) shall be sprayed in layers to produce overall 80 mm average thick closed cell polyurethane foam over the spraying surface with the help of appropriate foaming Machine. Precautions shall be taken to cover the nearby areas to avoid Spray of PU Foam on the other areas. The termination of spray at the corners shall be done as per IS:12432 (part 3):2000. The material should comply to thermal conductivity of 0.023 W/m. K at 25°C mean temperature (as per ASTM C518/91), U-value of 0.33 meeting the requirement of ECBC, tensile strength of >400 kPa (as per ASTM D 1623/78), compressive strength >300 kPa (as per ASTM D 1623-03), closed cell content having apparent VOI of 96-98% (as per ASTM D 2856) and fire resistance property confirming to Class 82 as per DIN 4102. | 590 | Sqm | 1,800 ₹10,62,000 | 950 ₹5,60,500 Lowest | 1,800 ₹10,62,000 | 2,100 ₹12,39,000 | 1,790 ₹10,56,100 | 1,500 ₹8,85,000 |
| 8.00 | M&L Separation Layer-Loosely lay minimum 150 GSM Geotextile (non-woven polyester) with a min of 75 mm wide overlap for Protection of the installed system. | 590 | Sqm | 150 ₹88,500 | 650 ₹3,83,500 | 60 ₹35,400 Lowest | 60 ₹35,400 Lowest | 69 ₹40,710 | 90 ₹53,100 |
| 9.00 | M&L for Cement concrete type B-1, 1:2:4 (20 mm graded aggregate) Avg 40 mm thick with water proofing compound as per manufacturer instruction in roof pedding in panels with 10mm wide construction/ dummy joint and filling the panel joints with Polyurethane Sealant. , finished even and smooth without using extra cement ,including cleaning the concrete surface by steel wire brushes, up to three stories bldgs, complete. | 590 | Sqm | 180 ₹1,06,200 Lowest | 250 ₹1,47,500 | 250 ₹1,47,500 | 399 ₹2,35,410 | 299 ₹1,76,410 | 400 ₹2,36,000 |
| 10.00 | M&L SRI Coating- Applying Two coats of a fiber-reinforced liquid applied elastomeric waterproofing membrane with Polyurethane modified binder& impregnated with synthetic fiber to be applied over the self-primed surface in an interval of 4-6 hrs. The topcoats should be applied with brush/roller/Spray. The deposition should be min 1.2 kg per Sq.mt. The Crack Bridging of the product should be minimum 1.5 mm & SRI value should be greater than 106. The priming coat should be self- priming with a dilution of 40% with potable water. This layer includes 1 priming coat+ 2 undiluted Topcoats. | 590 | Sqm | 700 ₹4,13,000 | 550 ₹3,24,500 | 500 ₹2,95,000 | 1,000 ₹5,90,000 | 450 ₹2,65,500 Lowest | 950 ₹5,60,500 |
Tender Value
₹1.4 Cr
EMD Value
₹2.2 L
Closing Date
19 Jul 2025, 6:00 pmClosed
CWE NEW DELHI
HQ CWE NEW DELHI
SPL REPAIR TO BLDG NO P77 OTM ACCN SHOPPING COMPLEX AT SHANKAR VIHAR UNDER GE SOUTH DELHI CANTT 10
2025_MES_711522_1
CWE-ND/13/2025-26
Open Tender
Civil Works - Others
Item Rate
180 days
DELHI CANTT
Please refer Tender documents.
9 documents required · 9 mandatory
₹1,000
GE (SOUTH) DELHI CANTT
₹2.2 L
29 Aug 2025
30 May 2025
21 Jul 2025
30 May 2025
19 Jul 2025
7 Jul 2025
Amount
M & L for Dismantling of brick tiles (laid flat or on edge) on roof surface.laid bedded and pointed in any mortar
M & L for Demolition of mud in roof, any thickness, including plastering and leeping upto two storey bldg incl necessary scaffolding arrangement complete all as specified and directed(whether full thickness removed or only a part there of) and removing from cantonment area or as directed complete all as directed by Engr in charge and specified.
M&L surface to be cleaned properly with wire brush to remove dust/loose particles from the surface. All the cracks should be opened in V groove and sealed properly with polyurethane sealant or polymer modified mortar. The surface should be oil and dirt free & in case of any unsound surface replastering to be done properly after application of SBR bonding coat. unsound horizontal surfaces to be filled with free-flowing micro concrete.
M&L for Cement concrete type B-0, 1:2:4 (12.5mm graded aggregate) as in roof pedding , finished even and smooth without using extra cement ,including cleaning the concrete surface by steel wire brushes, up to three stories bldgs, complete .
M&L single component Solvent based moisture cured polyurethane resin based low viscous highly penetrative primer to be mixed properly with electric mixture and to be applied by brush/roller over the entire surface. The deposition of primer should be minimum 200ml/Sq.mt however the same can be varied based upon surface porosity.
M&L Two coats of Single component non-UV resistant based polyurethane to be applied over the primed surface in an interval of 4-6 hrs. The topcoats should be applied with brush/ roller. No dilution is required for these two coats. A non-woven geotextile sheet of 60 GSM to be sandwiched between the layers. The deposition of PU should be 1.8 kg per Sq.mt providing avg thickness of 1.2 mm. The tensile strength of the product should be minimum 1.8 N/mm2. The elongation of the free film should be min 650% as per ASTM D412, Shore A Hardness should be min 45 as per ASTM D-2240, Crack Bridging @-9degree C min 1.5 as per ASTM C 836 & Solid Content should not be less than 90%. Moreover, the material should confirm to ASTM C-836, ASTM C-898.
M&L providing and applying roof insulation with Polyurethane Spray Foam, a two-component system. Polyol and Isocyanate are used in combination to produce rigid low density polyurethane spray foam. It gives good thermal insulation with 80 mm thick impervious sprayed, closed cell free Rigid Polyurethane foam - PU Spray PUF over deck insulation conforming to IS-12432 Pt. III (density of foam being 45-50 kg/ cum). The surface on which spray is applied to be cleaned properly, the moisture content in the surface shall be less than 5% and is to be dried before the application of spray, Polyurethane chemical (A side and B side) shall be sprayed in layers to produce overall 80 mm average thick closed cell polyurethane foam over the spraying surface with the help of appropriate foaming Machine. Precautions shall be taken to cover the nearby areas to avoid Spray of PU Foam on the other areas. The termination of spray at the corners shall be done as per IS:12432 (part 3):2000. The material should comply to thermal conductivity of 0.023 W/m. K at 25°C mean temperature (as per ASTM C518/91), U-value of 0.33 meeting the requirement of ECBC, tensile strength of >400 kPa (as per ASTM D 1623/78), compressive strength >300 kPa (as per ASTM D 1623-03), closed cell content having apparent VOI of 96-98% (as per ASTM D 2856) and fire resistance property confirming to Class 82 as per DIN 4102.
M&L Separation Layer-Loosely lay minimum 150 GSM Geotextile (non-woven polyester) with a min of 75 mm wide overlap for Protection of the installed system.
M&L for Cement concrete type B-1, 1:2:4 (20 mm graded aggregate) Avg 40 mm thick with water proofing compound as per manufacturer instruction in roof pedding in panels with 10mm wide construction/ dummy joint and filling the panel joints with Polyurethane Sealant. , finished even and smooth without using extra cement ,including cleaning the concrete surface by steel wire brushes, up to three stories bldgs, complete.
M&L SRI Coating- Applying Two coats of a fiber-reinforced liquid applied elastomeric waterproofing membrane with Polyurethane modified binder& impregnated with synthetic fiber to be applied over the self-primed surface in an interval of 4-6 hrs. The topcoats should be applied with brush/roller/Spray. The deposition should be min 1.2 kg per Sq.mt. The Crack Bridging of the product should be minimum 1.5 mm & SRI value should be greater than 106. The priming coat should be self- priming with a dilution of 40% with potable water. This layer includes 1 priming coat+ 2 undiluted Topcoats.
M&L for chipping out spilled and loose concrete cover and derusting steel reinforcement of concrete column, beam, slab, chajjas, parapets and the like as directed up to 25 to 35mm thick roughening and cleaning concrete surface with steel wire brushes, washed with water and allowed to dry including derusting steel wire reinforcement, providing fabric MS wire mesh 75 x 75 x 2mm as reinforcement to concrete surface applying adhesive/admixture over steel mesh and providing 25mm average thickness guniting mix using one part of OPC 53 grade and two part of sand mixed with adhesive/admixture @ pressure of 2.5 to 3.00kg/Sqcm by guiniting machine and surface finished even and fair including necessary padding, shuttering/scaffolding, formwork (guniting work to be carried out up to 10 metre height) complete as directed at site Note :- (a) After placing the additional reinforcement all concrete surfaces shall be thoroughly scrubbed with wire brushes, washed with water and allow to dry, apply chemistic polycretes admixture @ 2.25 kg by weight of cement all as per manufacturers instruction. (b) when polymix concreting in taking condition,guiniting is done with polycrete admixture @ 2% by weight of cement all as per manufacturers instructions (polycrete admixture shall be procured from chemical adhesive Pvt Ltd Co or their authorised dealer). (c) Cost of the above aspect shall be deemed to be included in the quoted rate of the respective item and nothing extra shall be paid on any account.
Dismentling of brick work built in cement mortar, including all quoins, arches, pillars etc of any description including removing debrish from site complete all as specified and as directed
M&L Brick work except bricks , straight or curved on plan exc 6 m mean radius built in cement mortar (1:6),(up to two story Bldg) complete all as specified.
M&L Brick work with sub class "B" bricks , straight or curved on plan exc 6 m mean radius built in cement mortar (1:6),(up to two story Bldg) complete all as specified.
M&L Brick work with sub class "B" bricks , straight or curved on in half brick thick wall built in cement mortar (1:4),(up to two story bldgs) complete all as specified.
Dismantling boarding, any description, fixed in any position with nail or otherwise complete all as specified and as directed
M&L for 18 mm thick wood plastic composites (WPC) board, 100% solid with density not less than 650 Kg per cubic meter , one side wood grain finished laminated for exposed/external surface for cladding , including all necessary fittings, fixtures and taping on edges if required complete all as specified and directed. Note : (a) Pattern & design of WPC board to be decided by GE.
Demolition of stone slab and tiles of any description or thickness on cooking platform, floors, aprons, skirting etc laid bedded and pointed in any morter complete all as specified and directed
M & L for Machine cut 18-20 mm thick Kota stone slab flooring as in treads of staircase over cement screed base 15mm thick in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing to mirror finish complete.
M & L for Kota stone slab 18-20 mm thick in riser of steps, skirting, dado and pillar, laid over cement screed of 10mm in CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing to mirror finish complete.
M&L for polishing of existing kota stone for rubbing and polishing to mirror finish complete all as directed.
M & L for Granite (of any type) work, 18-20 mm thk (table rubbed and polished) in steps, jambs, pillars, cooking platforms, skirtings, walls with necessary and likes on cement mortar bedding of 20mm thick in CM 1:6 including pointing in white cement using marble dust with admixture of pigment to match including rounded edges with shade of granite complete all as specified and directed.
S&F ACP sheet 4 mm thick of any shape, size , pattern and colour including fitting/fixture to fixed on wall / ceiling complete all as specified and directed .
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises
M&L for Udaipur green marble work 18 to 20mm thick (table rubbed and polished) in steps, riser/skirting, jambs, pillars, window cills, and like including including 20mm thick screed bed in CM 1:6 and pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade complete all as specified and directed.
M & L for Glazed Ceramic coloured tiles in vertical surface 600X300X7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match and including 10mm thick backing coat of cement mortar (1:4), complete all as specified and directed
M&L Non Skid ceramic tiles 8 to 10 mm thick (square/rectangular) area of each tile exceeding 0.06 but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including screed bed or bedding layer of mortar 15mm thick in CM 1:6 complete all as specified and directed.
M&L for Vitrified Ceramic tiles , double charged light shade 8- 10 mm thick (square/rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm of size (600mm X 1200mm), in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete laid over 15mm thick cement mortar screed bed of CM (1:6) complete all as specified and as directed
M&L for vitrified ceramic tiles double charged (light shade) 8-10 mm thick (Square/ rectangular) area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm of size (600mm X 1200mm), in floors etc. as in skirting laid on 10mm thick cement plaster in CM (1:4) , set and jointed in neat cement slurry at the rate of 3 kg per sqm and pointed in white/coloured cement to match the shade of tiles complete all as specified and as directed
S&F in repair Vitreous china wash down water closet pan sinlge piece syphonic action , white fixed in repair,including soft close sheet cover of closed pattern with flat bottom complete. Cat part No Hindware 20121 or equivalent
S&F in repair CP brass health faucet with hand shower and 1.5 mtr flexible stainless steel pipe suitable for fixing to 15 mm dia pipe complete.
S & F in repair Toilet paper holder of mild steel Chromium plated ‘D’ type, fixed in repairs to walls with chromium plated brass screws complete. Make-Cera CAT Part No: F5004110, Jaquar CAT Part No.CPA-CHR-1153, Hindware CAT Part No.F-880003CP, Kohler CAT Part No K-5633IN-CP
S & F in repair Vitreous china wash basin with pedestal pattern white, flat back, size 550 x 400mm, including necessary waste pipe and coupling, brackets and cutting for and pinning in ends of brackets, complete. Make. Cera ,Jaquar, Hindware
S&F in repairs wash hand basin mixer 15mm dia CP brass fancy type including joints to steel pipe or unions all as specified. Make- Jaquar CAT Part No: FLR-CHR-5167NB, Cera CAT Part No: F-2008461, Hindware CAT Part No. F570014, Kohler CAT Part No. K-29928IN-4ND-C
S&F in repairs 15 mm bib tap, brass chromium plated fancy type (quarter turn), long body screwed down including necessary extention piece complete. Make. Cera ,Jaquar, Hindware
S&F in repair 15 mm dia brass chromium plated angle valve fancy type (quarter turn), screwed at ends including necessary extention piece and fixed complete. Make. Cera ,Jaquar, Hindware
S&F urinal full size stall type white with waste coupling and waste pipe including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement , including urinal spreader of PTMT any colour for fixing with 15 mm dia pipe complete all as specified and directed . Make. Cera ,Jaquar, Hindware
S&F in repairs Good quality Connecton pipe (PVC) 15 mm dia and 450/600mm long complete all as specified.
Dismantling of floor of size exc 1.5 Sqm and not exceeding 4.00 Sqm mtr for EWC water closet and removing out the cinder/concrete from sunken protion, , grinding any sharp edges etc all as specified and directed with following: (a) Cleaning of RCC surface to remove dust, loose particle etc with compressed air or any other particles or any other suitable techniques on site conditions etc. (b) M&L for a glass fibre reinforced acrylic modified cementitious coating system with base coat of Sika Top & Seal-107 @ 1.50 Kg/Sqm glass fibre reinforcement Sika® Fab-I and top coat with Sika Top® Seal-107 @ 1.50 Kg/Sqm or equivalent of Fosroc or Pidilite. (c) M&L for protection plaster 15mm thick on cement mortar 1:3 admixed with appropriate integral water proofing compound with Sika ® Plastocrete plus as specified. (d) M&L for providing 40 mm dia GI pipe spout projecting at least 150 mm beyond outer face of wall. (e) M&L for sunken portion filled with 40 mm graded brick bats and finished with 50 mm thick PCC 1:2:4 type B1 all as specified and directed. (f) The area of Each WC portion is n.exc 4.00 Sqm each. (g) Cost of the above aspect shall be deemed to be included in the quoted rates of the respective item and nothing extra shall be paid on this account. (h) 72 hrs Ponding test shall be carried out for sunken treatment before payment.
Dismantling of floor of size not exceeding 1.50 Sqm mtr for EWC water closet and removing out the cinder/concrete from sunken protion, , grinding any sharp edges etc all as specified and directed with following: (a) Cleaning of RCC surface to remove dust, loose particle etc with compressed air or any other particles or any other suitable techniques on site conditions etc. (b) M&L for a glass fibre reinforced acrylic modified cementitious coating system with base coat of Sika Top & Seal-107 @ 1.50 Kg/Sqm glass fibre reinforcement Sika® Fab-I and top coat with Sika Top® Seal-107 @ 1.50 Kg/Sqm or equivalent of Fosroc or Pidilite. (c) M&L for protection plaster 15mm thick on cement mortar 1:3 admixed with appropriate integral water proofing compound with Sika ® Plastocrete plus as specified. (d) M&L for providing 40 mm dia GI pipe spout projecting at least 150 mm beyond outer face of wall. (e) M&L for sunken portion filled with 40 mm graded brick bats and finished with 50 mm thick PCC 1:2:4 type B1 all as specified and directed. (f) The area of Each WC portion is n.exc 1.50 Sqm each. (g) Cost of the above aspect shall be deemed to be included in the quoted rates of the respective item and nothing extra shall be paid on this account. (h) 72 hrs Ponding test shall be carried out for sunken treatment before payment.
Taking down (Door) chowkats or frames with shutters not exceeding 1.5 Sqm each (without taking off shutters from the frames) complete.
Taking down (Door) chowkats or frames with shutters exceeding 1.5 Sqm but not exceeding 4.00 Sqm each (without taking off shutters from the frames) complete.
M & L for Cement concrete 1:2:4 type B0 using 12.5 mm graded stone aggregate as in back filling, holdfasts etc, complete all as specified and directed.
S&F Factory Made single extruded WPC (Wood Polymer Composite) Solid door/window/Ceosetory windows & other frames/ chowkat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers( wood powder/ rice husk/ wheat husk) and nontoxic additives ( max toxicityindex of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face & 1100 N Edge), min compressive strength of 58N/sqmm and resistance to flame of class A category with property of being termite/ borer proof, water/ moisture proof and fire retardant and fixed with MS Holdfast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engr in charge. Note: -For WPC solid door/windows frames, minus 5mm tolerance in dimension i.e., depth and width of profile dimension on plus side shall be acceptable but no extra payment on this account shall be made.
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and nontoxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of EngineerIn- Charge. (Note: stainless steel butt hinges shall be paid separately under relevant item).
S&F 100mm long (size) butt hinges, stainless steel AISI 304 grade with brass/bronze hinge pin complete
S&F stainless steel AISI 304 grade barrel tower bolt 200mm long, extruded section,etc. complete all as specified and directed.
S&F stainless steel AISI 304 grade handle of size 200mm long,etc. complete all as specified and directed.
S&F Stainless steel of AE SI 304 Grade, sliding door bolt 300mm long with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts & sliding bolts of extruded sections or cast aluminium alloy complete.
S & F Floor door stopper (double leg) of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor; overall length of cover plate 60mm complete.
Taking down of window shutter of any size and description complete all as specified and as directed
S&F powder coated anodised aluminium frame as in door , window, ventilator and shutter etc. with one or more rebates including joining cleat for fixing etc. fixed type/louvered/sliding window or ventilators without sash bar, aluminium including necessary joining cleat, glazing clips, rubber packing, anodised aluminium snapbeading, screw etc complete all as specified and directed by Eng-in-charge. Note: (a) Glazing shall be measured seperatly ; (b) Items shall be paid as per weight of of aluminium sections . (c) The rates quoted shall be inclusive of neoprene beading glazing clips , screws , etc as required whichshall not be measured for arriving the weight (d) The rate shall be inclusive of locking arrangement including complete all as specified and as directed
S&F in repair 4.8 mm thick sheet glass ordinary quality and glazing with Al glazing clips& EPDM beading in square exc 0.5 sqm in each pane complete all as specified and as directed
Dismantling wrought iron or mild steel/cast iron work of any description complete all as specified
M & L for Mild steel Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, welded or forged into spikes, framed guard bars, window frames, barred iron doors, ladders, framed balusters, walk ways, MS sheet , plate , railings, framework of water tanks and similar work fixed in position including holdfasts or screws confirming to Fe.290.Gde-E-165 complete all as specified.
M & L for Mild steel ornamental and intricate design framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, welded or forged into spikes, framed guard bars, window frames, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work fixed in position including holdfasts or screws confirming to Fe.290.Gde-E-165 complete all as specified.
M & L for preparation of new Steel surfaces of any description not otherwise described over 10 cms width or girth and apply two coats of synthetic enamel paint over a coat of red oxide zinc chromate primer all as specified.
M & L for preparation of old Steel surfaces of any description not otherwise described over 10 cms width or girth and apply one coats of synthetic enamel paint all as specified.
Taking up or down steel tubing and connections all as specified.
a) 15 mm bore
b) 20 mm bore
c) 25 mm bore
Supplying and laying of CPVC 20mm OD pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors incl brass coupling fittings complete all as specified complete with fitting as required.
Supplying and laying of CPVC 25 mm OD pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors incl brass coupling fittings complete all as specified complete with fitting as required.
Dismantling water tanks of capacity exceeding 500 litres but not exceeding 1000 litres complete.
Dismantling water tanks of capacity exceeding 250 litres but not exceeding 500 litres complete.
M&L for rotational moulded polythylene water storage tanks 500 litres capacity (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified in SSR-I including brass valve high pressure with polythne float and fly nut , tank nipple as required complete, screwd for iron pipe or brass ferrule size 25 mm bore complete all as specified and as directed
M&L for rotational moulded polythylene water storage tanks 1000 litres capacity (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified in SSR-I including brass valve high pressure with polythne float and fly nut , tank nipple as required complete, screwd for iron pipe or brass ferrule size 25 mm bore complete all as specified and as directed
S & F in repairs Gun metal globe or gate valves, with iron wheel head, screwed both ends for PVC pipe 20 mm bore complete.
S & F in repairs Gun metal globe or gate valves, with iron wheel head, screwed both ends for PVC pipe 25 mm bore complete.
Dismantling of cast iron or reinforced concrete drains pipes , jointed in cement morter and taking out of trenches if required up to 100 mm internal dia of drains, complete all as specified and directed.
S&F 110 mm uPVC pipes Type 'B' (for waste water), single socketed, in any length with rubber ring joints, laid in trenches or in floors or fixed to walls complete all as specified and directed.
S&F 75 mm uPVC pipes Type 'B' (for waste water), single socketed, in any length with rubber ring joints, laid in trenches or in floors or fixed to walls complete all as specified and directed.
S&F 110 mm uPVC (SWR) Bends/ Tees/ Tapers (any radius), with or without oval access door as required complete all as specified and directed.
S&F 75 mm uPVC (SWR) Bends/ Tees/ Tapers (any radius), with or without oval access door as required complete all as specified and directed.
S&F in repairs uPVC multi floor trap with grating including jointing with solvent cement, dia of outlet 75mm complete all as specified and directed.
S&F, 100 mm sand cast iron soil waste and vent pipes , in any length with or without ears , with cement joints laid in trenches or in floors,complete all as specified and directed.
M&L for 100mm Cast iron Bends (any radius) , Tee , branch piece, diminishing pieces or tapers (larger bore measured) complete.
S & F Stack clamps out of 50mm x 5mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof, for any bore and any type of pipes complete.
Taking down cement or cement lime plaster, any description, on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water etc including removal of debrish from the MOD land complete all as specified and directed.
M/L cement plaster 15mm thick in CM 1:6 on brick or conc surfaces finished even and smooth without using extra cement mixed with by adding permeability reducing polymer @ 250gm/sqm (6%) by weight of cementitious content at time of mixing with water as per manufacturer's recommendations including all levelling the surface, curing etc complete. NOTE : Rates for water proofing compound/ polymer deemed to be included in the above rates.
M &L for providing and applying a bond coat of Latex:Water:cement - 1:4:6 consumption @100gm/sqm on the brick wall surface by brush as per manufacturer's recommendations including curing complete.
Expose the first joint of masonry structure at ground level horizontally. The plaster must be knocked off at least 50 cm beyond the visibly penetrated area. Damaged mortar joints are to be scraped out to a depth of approximately 2-3 cm. Drilling Holes : Drilling holes 10mm diameter in masonary structure along the side of the joint as per manufacturer's instructions so as to cross the brick/ block at the intervals spacing of 15-30cm depending on extent of rising dampness as per recommendation of engineer in charge. Cleaning of holes : Clean the holes by air blower prior to fixing nozzles. Install latex polymer packer injection packers 9.8mm diameter, 10cm long in the holes and tighten. Fix the packer securely using sealent. Cutting of Packers : Cut the packers after completion of grouting without damaging structural elements.
Supply and apply of a 3 part, very low viscous, elastic polyacrylic injection resin with a versatile and adjustable reaction time having Mixed viscosity : 3-11 M.pa.s at +20 Deg C, Reaction time : adjustable according to ambient temperatrure and execution requirement between 8-50 mins, pH – 9-10, tested as per Wissbau No. 2002-094-(1A) – Function test with re-injectible hose system. The holes should be drilled until a depth of approx 5 cm (for a 6cm thick wall) before the end of the wall is reached. Pump injcection of polymer resin compound at >20 bar into or behind fissures or into masonry joint which are allowing water to infiltrate into unwanted areas. If voids in masonry being injected contain insufficient moisture to activate the grout inject a small amount of water prior to injecting the grout. When movement stops or polymer compound appears at the packer move to the next packer and inject. If the dampness is heavy, inject similarly at next joint line
M&L for 15mm thick rendering with ready mix plaster on faces of brick or concrete wall surface, finished even and smooth complete all as specified and directed.
M&L for 10 mm thick average rendering with ready mix plaster on faces of brick/ concrete wall surface finished even & smooth complete all as specified.
M&L for rendering 5 mm thick in Cement Mortar (1:3) on ceiling finished even and fair without using extra cement complete all as specified and directed.
Preparation of the newly plastered surfaces of walls/ ceiling and M&L applying two coats on walls/ceiling with spray machine, of GreenPro certified water-based, modified acrylic, exterior Apex Suprema Emulsion or equivalent as per required shade (Company depot tinted) with silicon additives, heat reflectant property, VOC less than 2% by mass, Class A IS-15489 and IS-101 @5-6 sqm/ltr over a coat of primer, necessary tools and machinery to give an even shade and applying one coat of waterproofing wall putty avg 1-1.5 mm thick suitable for external surafce . Application to be done only by applicator authorised by manufacturer, also shall be approved by GE before starting of work.
Removal of existing loose treatment by scraping with mechanical wall/ceiling by vacuum based sanding machine (wall sanding machine with internal dust extraction system & having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 80 grit having dia of 7 inch/ 9 inches to make the surfaces free from dust, loose paint etc by using smart periodical methodology/auto roller and M&L for two coats spray machine, of GreenPro certified water-based, modified acrylic, exterior Apex Suprema Emulsion or equivalent as per required shade (Company depot tinted) with silicon additives, heat reflectant property, VOC less than 2% by mass, Class A IS-15489 and IS-101 @5-6sqm/ltr over a coat of primer, necessary tools and machinery to give an even shade and applying one coat of waterproofing wall putty avg 1-1.5 mm thick suitable for external surface . Application to be done only by applicator authorized by manufacturer, also shall be approved by GE before starting of work
Preparation of the newly plastered surfaces of walls/ ceiling and M&L applying two coats of distemper oil emulsion, with spray machine on wall/ ceilling surface white or tinted over one coat of primer with and including 1mm thick wall care putty to obtain an even surface necessary tools and machinery to give an even shade. Application to be done only by applicator authorised by manufacturer, also shall be approved by GE before starting of work
Removal of existing loose treatment by scraping with mechanical wall/ceiling by vacuum based sanding machine (wall sanding machine with internal dust extraction system & having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 80 grit having dia of 7 inch/ 9 inches to make the surfaces free from dust, loose paint etc by using smart periodical methodology/auto roller and M&L applying two coats of distemper oil emulsion, with spray machine on wall/ ceilling surface white or tinted over one coat of primer with and including 1mm thick wall care putty to obtain an even surface necessary tools and machinery to give an even shade. Application to be done only by applicator authorised by manufacturer, also shall be approved by GE before starting of work
S&F in repair steel rolling shutters, thickness of lath 1 .25 mm, with out ball bearing, including top cover, anchoring rod , hasp & staple and one shop coat of primer, erected in position including gear operated type with bevel gear box , side guide rail and crank handle, complete as directed . Note : Above quoted rates includes all fitting and fixture for manually operated bevel gear box rolling shutter operational .
M&L for preparation of new Steel surfaces exc 10cm width or girth and applying one coat of aluminium paint of approved shade/tint
Demolition of cement concrete (unreinforced) in any description and in any position not otherwise specially provided for.
S&F Factory made precast cement concrete rounded edge kerb stone of size 300mm in ht and 150mm thk, cast in cement concrete (1:2:4) Type B1 (using 20 mm graded stone aggregate) set and jointed in cement mortar 1:4 including returning filling in earth work dispanced during removal and refiling of earth up to a level as required and well rammed complete all as directed.
M&L for 75 mm thick cement concrete type D-2, 1:4:8 (40mm graded stone aggregate) as in sub base for drain etc complete all as specified and as directed.
S&F for Pre-cast U shape RCC drains 80 mm thick size 400 wide x 600 mm (drain measured out to out) and depth 300 to 500 mm (T-25) including S&F SFRC perforated drain cover size 400 mm x 600 mm x 80 mm thickness complete all as of make M/s Fuji Silvertech or equivalent all as specified and as directed.
S&F precast factory made M-30 concrete saucer drain of 600 mm long 300 mm wide and 100 mm thick set in CM 1;4 including necessary earthwork/demolition of existing pcc drain etc complete all as specified and as directed
M&L HDPE DWC gully trap 150 mm, setting and jointing with solvent cement complete all as specified and as directed.
S&F in repair factory made FRP gully trap cover with locking arrangement commercial grade having loading capacity 2.5 tone of size 300 x 300 mm with frame set in cement mortar 1:4 complete all as specified and as directed.
Excavation in trenches n.exc. 1.5m wide and n.exc. 1.5m in depth for manholes and sewage line and getting out in soft/loose soil
M&L concrete bed to drain in PCC 1:3:6 type C2 incl packing under and haunching against the sides of pipes after they are laid and tested in bore of pipe 150 mm dia pipe
M&L for DWC HDPE SN8 sewage pipe of dia 150 mm laid and jointed including reducer to fit 100 mm GT outlet complete all as specified and as directed.
Returning, filling including spreading, levelling, watering and well ramming in layers n.exc 25cm
M&L for view cutter for restricting dust, debries and seprating work site for functioning shops upto desired height with MS frame and high density green cloth, MS frame shall be erected to with stand high speed wind and including fixing of green cloth with frame complete all as specfied and directed by Engineer-in-charge. Note: Any damaged to view cutter during contract will be repaired/ replaced by contractor and amount deemed to be included in above quoted rate.
Dismentling of view cutter as above and finishing damaged surface to match adjacent surface complete all as specified and directed.
Removing excavated materials exc 50m but nexc 250m at a level n.exc. 1.50 above the starting point and depositing where directed by Engineer-in-Charge
Taking down carefully the old U/S Copper point wiring (light, fan, socket or power) complete Fitting such as switch, ceiling roses,pendants,socket, regulators , all type light Fitting, security light Ding Dong Bell , etc and making good disturbed surfaces of walls including necessary touch up with the adjoining surface of disturbed area ie with OBD/colour wash/white wash as the existing finish complete.
M&L for concealed point wiring complete with stranded copper conductor 1.5 Sqmm nominal area PVC insulated single core unsheathed FRLS 1100 volts grade electrical cable drawn through existing concealed PVC conduit in wall and ceiling including replacement of unserviceable pressed steel terminal boxes with Modular steel terminal boxes of min thickness 1.2mm with 120 GSM coating including white cover modular plate with frame suitable for modular switches, modular sockets, modular fan regulators etc of required size complete including 1.5 sqmm copper cable single core PVC insulated unsheathed earth continuity wire to common earth and connected to earth dolly complete all as specified and as directed. Notes (i): The rates are inclusive of providing point wiring on casing caping, if there is blockage/damage in existing conduit on ceiling. (ii) :The rates are inclusive of cutting / chasing and making good disturbed surfaces with CM 1:3 and same finishes with adjoining surfaces of disturbed area with OBD/ Colour wash/ white wash etc as per site requirement.
All as per Srl No.110 above One light /fan/Bell point/security light controlled by one way switch
All as per Srl No.110 above One 3 pin socket outlet 5 amps on same board
All as per item Srl item No.110 here in before, but for one three pin socket outlet 6 amps point controlled by one no, one way switch on independent board and through new concealed conduit complete.
All as per Srl No.110 above One 3 pin socket outlet, 15 amps on independent board with cable 2.5 Sqmm for main current and 2.5 sqmm as earth wire as power point complete all as specified and directed.
All as per item Srl item No.110 here in before, but with using 4.0 sqmm single core cable and 4.0 sqmm single core cable (for continuous earth wire) for independent circuit and through new concealed conduit complete.
S & F Switch Modular type switch, 6 A 1- way SP switchwith finger proof terminal complete all as specified and directed by Engineer in Charge
S & F modular type 2/3 pin combined shuttered type 6A socket, complete all as specified and directed by Engineer in Charge
S & F Switch Modular type switch, 16 A 1- way SP switch with finger proof terminal complete all as specified and directed by Engineer in Charge
S & F modular type 2/3 pin combined shuttered type 16 A socket,complete all as specified and directed by Engineer in Charge
S&F modular AC box with 20 Amp SP MCB complete all as specified and directed by Engineer in Charge
S & F 6 A 250V ceiling rose having terminal capacity 3X1.5mm2 with IK 04 and IP 20 protection complete all and directed by Engineer in Charge
Refixing of serviceable light fitting reteived against item No 1 here in before including electrical connection complete all as specified and as directed.
S & F 20 Watt surface / wall mounted LED batten having PC diffuser luminius efficincy not less thn 120 lumen/Watt CRI>80% PF>0.9,CCT 6500K indeoendent isolated SPMS based constant current electronic LED driver with THD < 10% surge protection nd other safety tests as per IS 15885( Part-2/Sec-13) : 2012 polycarbonate diffuser housed in power coated white extruded aluminium channel housing , white coloured ABS end caps IP 20protection input voltage range 140-270V input fequency 50-60Hz including electrical connection with 3 core flexible Cooper Cunductor cable of Appropriate size from ceiling rose to the fixture complete all as specified and directed by Engineer in Charge
S& F recessed/surface mounting 36 watt 2' x 2' flat LED panel fitting with soft light and glare free symetrical ilumination suitable for RCC/POP ceiling supplied with wedge bracket to fix in existing ceiling in replacement of existing old unsv CFL fitting any type from ceiling of common areas and making good disturbed surface/POP ceiling to match and getting electrically connected the fitting with switch board for suitable size of PVC copper wire complete all as specified and directed by Engr-in-Charge.
Taking down VTPN DB & DB's of SPN/TPN 4/8/16 way type removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls etc. complete all as specified and as directed.
S&F in replacement of VTPN 6 Way Modular type double door mettalic DB conforming to IEC 61439-3 suitable for flush / surface mounting having 250 A copper busbar fully shrouded neutral bar earth bar wire sey & cable ties for cable management pre fiited sheet etc. Having IK 09 & IP 43 protection complete all as specified in IS 732:2019 and directed by Engineer in Charge
S&F in replacement of MCCB 4 pole curve 160 Amps, 415 Volts with 25 KA including electrical connection with incomer with appropriate size of aluminium lugs and insulation packing complete all as specified and directed.
S&F in replacement of MCCB 4 pole curve 100 Amps, 415 Volts with 25 KA including electrical connection with incomer with appropriate size of aluminium lugs and insulation packing complete all as specified and directed.
Supply and fix in replacement of TPN DB 16 Way double door mettalic DB conforming to IEC 61439-3 suitable for flush / surface mounting having 100 A copper busbar fully shrouded neutral bar earth bar wire set & cable ties for cable management pre fiited sheet etc. Having IK 09 & IP 43 protection complete all as specified in IS 732:2019 and directed by Engineer in Charge
Supply and fix in replacement of SPN DB 8 Way double door mettalic DB conforming to IEC 61439-3 suitable for flush / surface mounting having 100 A copper busbar fully shrouded neutral bar earth bar wire set & cable ties for cable management pre fiited sheet etc. Having IK 09 & IP 43 protection complete all as specified in IS 732:2019 and directed by Engineer in Charge
Supply and fix in replacement of SPN DB 4 Way double door mettalic DB conforming to IEC 61439-3 suitable for flush / surface mounting having 100 A copper busbar fully shrouded neutral bar earth bar wire set & cable ties for cable management pre fiited sheet etc. Having IK 09 & IP 43 protection complete all as specified in IS 732:2019 and directed by Engineer in Charge
Taking down MCB any type removing and materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls etc. complete all as specified and as directed.
M&L in replacement MCB TPN 'C' curve 63 Amps 415 Volts , 10 KA complete all as specified and directed.
M&L in replacement MCB SPN 'C' curve 63 Amps 240 Volts , 10 KA complete all as specified and directed.
M&L in replacement MCB SP 'C' curve 40 Amps 240 Volts 10 KA complete all as specified and directed.
M&L in replacement MCB SP 'C' curve 32 Amps 240 Volts 10 KA complete all as specified and directed.
M&L in replacement MCB SP 'C' curve 06 to 32 Amps 240 Volts 10 KA complete all as specified and directed.
S &F in replacement for Earthing complete with galvanized steel earth plate 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate n.less than 1.5 m below normal ground level, connected to galvanized iron wire 4 mm as earthing lead by means of bolts, nuts, check nuts & washers of galvanized iron or steel besides building at all joints as shown in drgs and including excavation and earth work, GI pipe light grade 25mm bore of protection of GI wire from earth electrode, supply and laying charcoal dust, common salt, PCC (1:2:4) type B-1 Chamber and MS angle iron frame 40x40x3mm and RCC cover 40 mm thick (1:2:4) type B-1using 20 mm graded stone aggregate Reinforced with 6 mm dia round bars @ 75 mm C/C both ways with MS handle 12 mm dia , PGI funnel and wire mesh , 20 mm dia GI Pipe light grade for watering complete all as shown in drg and connected to earth test point including testing as directed by Engr-in-Charge.
M & L Earth continuity conductor or main earthing lead fixed on wall/ceiling in batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed on poles or any other indicated situation for loop earthing etc as required 4mm dia galvanised iron or steel wire.
Taking down unserviceable Submain wiring of any size complete and making good disturbed surface complete all as specified and directed.
S &F submain wiring of two runs of 10 Sqmm size for main cable and one run of 10 Sqmm size earth continuity conductor of single core PVC insulated but unsheathed FRLS cable of specified size multistranded copper conductor 1100 volts grade IS-694 marked , drawn in and including PVC concealed conduit of size 50 mm dia with complete all as specified and directed. Note : (i) Phase should be Red/Yellow/Blue, neutral should be black and earthing wire should be of green colour. (ii) Four runs of cable 10 Sqmm with 01 earth wire 10 sqmm & conduit shall be measured as one unit. (iiI) The rates are inclusive of Cutting / chasing and making good to disturbed surface with CM 1: 3 and same surface finishes with the adjoining surface of disturbed area with OBD/Colour wash /white wash complete.
S & F 35 Watt security light high efficiency long life LED module with SMD LED package mounted on MCPCB with high LED efficiency of 2600 Lumen/Watt integral SMPS based constant current electronic LED driver with THD<10% surge voltage protection and other safety tests as per IS:15885( part-2/sec-13),IP 66 protection high efficiency polycarbonate cover with integrated lens housed in pressure die cast aluminim alloy heat sink for effective thermal management strudiness excellent corrosion resistance separate optical and control gear compartment & Top opening for easy maintanance suitable for side entry wall mounting with bracket arm OD 35mm to 42 mm including necessary electrical connection to the fixture with 3 core flexible copper cunductor cable of appropriate size and 1.5m long bracket having 40mm diameter light grade GI pipe including GI clamp nuts bolts & washers with two coats of synthetic enemal paint over a coat of oxide primer complete all as specified and directed by Engineer in Charge
S&F LED post top 20W, 3000K made in dia cast aliminium bottom housing and spun aliminium top reflector with decorative clear acrylic diffuser and IP65 protection opal diffuser complete with all accessories all as specified and directed by engr in charge.
S&F in replacement Sheet metal enclosure of size 350 x 250 x 150 mm suitable for mounting Pre paid meter fabricated from CRCA sheet with anti corrosive dust and vermin proof. Note:- The meter cover shall have a transparent window. The window shall be of transparent, high grade UV stabilized engineering plastic for easy reading of all the displayed values/parameters and observation of operation indicator. The window shall preferably be an integral part of meter cover all as specified and directed.
Taking down and re fixing Eanergy meter including necessary connections of incoming and out going cables for light and power as specified and directed by Engr-in-charge.
Supplying and fixing smart single phase two wire dual source prepaid energy meters BIS 15884 marked in existing meter board /flo panels with pre payment capacity touch kepad based digital having current range 10-60 Amp 2340 Volt accuracy class 1.0 alongwith parallel home displays plit unit with inbuilt load control switch containing provision for TOD and RTC, inbuilt feature to sense the DG mode through PLSI, dual source registration wrt grid as well as DG supply and dynamic load allocation facility from grid and DG, capable to define for tarrif slabs, happy hours and holiday definition including implementation of vending system through server, mapping complete as directed. Note – Meter Should work on existing MES Delhi Cantt Server and cost of connecting to existing system is deemed to be included in the rates quoted.
Taking Up unserviceable u/g Cable of any size complete all as specified and directed.
Supply & laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sqmm 3.5 core complete all as specified and as directed by Engineer In Charge.
Excavation in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 metre in depth and getting out soft/loose soil, complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick, complete all as specified and directed by Engr-in-Charge.
Removing surplus soil to a distance n.exc 50m and deposited where directed at a level not exceeding 1.50 m above the starting point, complete, all as specified and directed by Engr-in-Charge.
supply and laying Double wall Corrugated (DWC pipe in excavation of trenched of 63 X 50 mm size including all connecting necessary items complete all as specified and directed.
LED Tube Light 20 W work on motion sensor technology that detects the presence of a person through a smart , built in occupancy and delivers sensor. It should provides 100% light at 20W during occupancy and delivers pleasant light 30% during Zero occupancy complete all as specified and directed by Engr-in-Charge.
tarun construction co (BID ID -3364330)
Parveen Builders (BID ID -3356208)
BEHAL TRADERS (BID ID -3355982)
M/S Chhavi Constructions Co (BID ID -3364543)
Chaudhary Constructions (BID ID -3356255)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .