| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.0 LAccepted-AOC PULGAON | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹21.8 L+₹1.2 L (6.05%)Rejected-Finance | L2 | Rejected-Finance Other than lowest tender | |
| 3 | L3₹22.1 L+₹1.5 L (7.39%)Rejected-Finance BHAVANI KRUPA GANDHI CHOWK PULGAON 442302 | WARDHA | MAHARASHTRA | 442302 | L3 | Rejected-Finance Other than lowest tender | |
| 4 | L4₹22.4 L+₹1.9 L (9.12%)Rejected-Finance | L4 | Rejected-Finance Other than lowest tender | |
| 5 | L5₹24.3 L+₹3.7 L (18.2%)Rejected-Finance 011 NAGAREWADI 612 NAGAREWADI POST PADALI TALUKA SHIRUR KASAR DISTRICT BEED 413249 BEED MAHARASHTRA 413249 UDYAM MH 05 0079863 | BEED | MAHARASHTRA | 413249 | L5 | Rejected-Finance Other than lowest tender |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
7 Dec 2020, 6:00 pmClosed
GE PULGAON
GE PULGAON
REPAIR/MAINTENANCE OF FIRE FIGHTING SERVICES, FIRE FIGHTING,FIRE ALARM SYSTEM AND CONNECTED MISC WORKS AT CAD PULGAON UNDER GE PULGAON
2020_MES_395666_1
8848/PUL/E8
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
GE PULGAON
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
Yes
GE PULGAON
₹40,000
Yes
13 Jan 2021
17 Nov 2020
9 Dec 2020
17 Nov 2020
7 Dec 2020
1 Dec 2020
17 Nov 2020 - 7 Dec 2020
Amount
Upkeep of following equipment /machinary installed at pump house in/near building No. P-6 comprising of foam sprinkler and water sprinkler system for cooling and washing of floor, stainless steel piping with large No of opening to maintain the required discharge of water, regular flow of foam for detecting defective items and periodical minor repairs such as oiling, greasing, rubber guskets and providing glands and all as necessary minor repairs required for proper functining of equipments all as directed by Engineer in Charge including all the items listed in below:-
Automatic foam sprinkler system including stainless steel tank complete and filling of foam as per direction.
Centrifugal pumping set electric driven - 01 set
Standby diesel engine operated centrifugal pumping set auto/manual start- 01 set
Jockey centrifugal pump electric driven auto/manual start- 01 set
Sluice valves, NRVs off sizes alongwith pipe line
LT Panel Board with all accessories and power cables.
Hooter-01 Each
Note:- (i) Testing will be carried out Monthly basis and contractor submit the test report duly signed by users rep every month and all as secified and directed by Engr-in-charge . Testing shall be measured and paid separately. (ii) Oil, grease , rubber guskets, and gland are deemed to be incl in above rates. (iii) Any welding work , cutting of exisitng pipes inserting MS/GI / CI fittings , replacing steel pipe , sprinkler is deemed to be incl in above rates. (iv) Docuuments as specified are maintined and put to EIC monthly. (v) Contractor shall arrange transportation of foam drum from AGE E/M store to Pump house and filling of foam in stainless steel tank insatalled at above bldgs deemed to included in above rates. (vi) Connected Spares required for replacement of unserviceable parts shall be measured and paid separately in supply and fix in repair. Note:- The Rate mentioned in Item No 1 For 1 Year Duration. Panel recovery of Rs 2000 Per Month shall be recovered if contractor fails to testing on monthly basis at due time.
All as per item No 1 ……………. but for buildings No P-14
Upkeep of following equipment /machinary installed at pump house in/near building No P-1 water sprinkler system for cooling & washing of floor of bldg No P-1 comprising of stainless steel piping with large No of opening to maintain the required discharge of water regular flow of foam for detecting defective items and periodical minor repairs such as oiling, greasing, rubber guskets and providing glands and all as necessary minor repairs required for proper functining of equipments all as directed by Engineer in Charge including all the items listed in below:-
Cetnrifugal pumping set electric driven - 04 set
Standby diesel engine operated centrifugal pumping set auto/manual start- 01 set
Jockey centrifugal pump electric driven auto/manual start- 01 set
Sluice valves, NRVs off sizes alongwith pipe line
LT Panel Board with all accessories and power cables.
Hooter-01 Each
Note:- (i) Testing will be carried out monthly basis and contractor submit the test report duly signed by users rep every month and all as specified and directed by Engr-in-Charge. Testing shall be measured and paid separately under respective items. (ii) Oil, grease, rubber guskets, and gland are deemed to be included in above rates. (iii) Any welding work , cutting of exisitng pipes inserting MS/GI / CI fittings , replacing steel pipe , sprinkler is deemed to be incl in above rates. (iv) Documents as specified are maintined and put to Engr-in-Charge monthly. (v) Connected Spares required for replacement of unserviceable parts shall be measured and paid separately in supply and fix in repair. (v) The quoted rate shall cover for entire period of 365 days(including Sunday and Holiday). Note:- The Rate mentioned in Item No 3 For 1 Year Duration. Panel recovery of Rs 2000 Per Month shall be recovered if contractor fails to testing on monthly basis at due time.
Upkeep of water sprinkler system for cooling & washing of floor of bldg No P-10 comprising of stainless steel piping with large No of opening to maintain the required discharge of water for detecting defective items and periodical minor repairs such as oiling, greasing, rubber guskets and providing glands and all as necessary minor repairs required for proper functining of equipments all as directed by Engineer in Charge.
Note:- (i) Testing will be carried out Monthly bases and contractor submit the test report duly signed by users rep every month and all as secified and directed by Engr-in-charge . Testaing shall be measured and paid separately. (ii) Oil, grease , rubber guskets, and gland are deemed to be incl in above rates. (iii) Any welding work , cutting of exisitng pipes inserting MS/GI / CI fittings , replacing steel pipe , sprinkler is deemed to be incl in above rates. (iv) Documents as specified are maintined and put to Engr-in-Charge monthly. . (v) Connected Spares required for replacement of unserviceable parts shall be measured and paid separately in supply and fix in repair. (v) The quoted rate shall cover for entire period of 365 days including Sunday and Holiday. Note:- The Rate mentioned in Item No 4 For 1 Year Duration. Panel recovery of Rs 2000 Per Month shall be recovered if contractor fails to testing on monthly basis at due time.
Testing of Foam Sprinkler system installed at P-6 and P-14 sheds complete all as specified and directed by Engr-in-Charge Note: One testing in one building will be one Job
Testing of water sprinkler system installed at P-1, P-6 P-10 and P-14 sheds complete all as specified and directed by Engr-in-Charge Note: One testing in one building will be one Job
Supply and fix in repairs foam spray nozzle made of stainless steel(SS304) construction with 1/2 " male BSP threaded inlet. The nozzle shall have K Factor of 30/45 and shall have aeratingarrangement to give foam of expansion 1:3 to 1:6 and suitable pattern for covarage of risk area
Supply & fix in repair Conventional 24 VDC Electronic Hooter cum Flasher. Make : spencer / Honeywell / Fire Light / NotiFier
Supply & fix in repair 15 mm (½") dia. NBCM Body chrome finished side wall type sprinkler / Spray nozzal Medium Velocity having rating with deflector disc of conventional construction with all accessories require to install. Make: Kartar / Shah Bhogilal / HD / Newage
Maintenance & repair fire hydrant system installed at bldg shed No P-1 to P-14 'F' sub Depot including maintenance of following Parts all as specified and directed by Engr-in-Charge.
Fire hydrant valves from outside and inside
Fire boxes from outside and insde
Female coupling lugs and repair to spring nut
Hose reel leakage and make good the same
Gland, all rubber parts
Note:- (i) Testing will be carried out quaterly basis and contractor submit the test report duly signed by users rep every quarter and all as specified and directed by Engr-in-Charge. Testing charges shall deemed to be included in unit rate quoted. (ii) Oil, grease, rubber guskets, and gland are deemed to be included in above rates. (iii) Any lathwork, welding work , cutting of exisitng pipes inserting MS/GI / CI fittings , replacing steel pipe , sprinkler is deemed to be incl in above rates. (iv) Documents as specified are maintined and put to Engr-in-Charge monthly. (v) Connected Spares required for replacement of unserviceable parts shall be measured and paid separately as supply and fix as and when required. (vi) M & R shall be quarterly and considered one job for one bldg. (vii) Panel recovery of Rs 3000 Per Qtr shall be recovered if contractor fails to testing on quarterly basis at due time.
Supply and fix in repair Weather proof hose cabinet of size 750 x 600 x 250 mm fabricated from M.S. angle iron sections and 18 GMS sheet with full glass door and locking arrangement suitable to accommodate - 2Nos 15 M long hoses and 1 No branch pipe and nozzle including stand of exisitng height . The cabinet shall be painted with one coat of primer and two coats of primer and two or more coats of synthetic enamel paint or approved make and shade and shall be suitably mounted.
Supply and fix in repair SS 304 Short Branch Pipe 63 mm with necessary accessories conforming to IS : 903 ISI marked. (Make : Newage / Swati / Shah Bhogilal /. Arihant)
Supply and fix in repair of Hydrant Valve Oblique Type 63 mm complete made out of SS 304 fitted with PVC main blank cap and GI Chain IS 5290 with ISI mark (Make : Newage/Kartar/Shah Bhogilal / Arihant)
Supply and fix in repair Hydrant valve wheel cast iron type suitable for 63mm dia hydrant valve
Supply and fix in replace RRL hose pipe 63 mm dia with male and female coupling with ISI mark all asspecified and directed by Engr-in-Charge
Supply and fix in repair Hydrant cap with chain for hydrant valve 63mm dia
M & L for painting of fire hydrand boxes with stand, Hydrand Valves and MS pipe over the ground level after prepation of old painted surface with one two coat of exisiting colour synthetic enamelled paint complete all as specified and directed by Engr-in-Charge.
Maintenance & repairs to smoke / heat detector as well as reppeater automatic fire alarm system complete with fixed temperature,heat detector,main control panel cabling 24 volt SC with FRLScable with rectifier,24 volts battery with charger unit complete installed at P-1, P-6 P-10 and P-14 sheds of 'F' sub depot and 104 AC shed in 'B' sub depot all as spcified and directed by Engr-in-Charge. Note :- (i) Testing will be carried out Quartely bases and contractor submit the test report duly signed by users rep every quarter and all as secified and directed by Engr-in-charge . (ii) Documents as specified are maintined and put to Engr-in-charge monthly. (iii) Connected Spares required for replacement of unserviceable parts shall be measured and paid separately in Supply & fix in repair (iv) M & R of heat detectors or smoke detectors and repeater fire alarm system in one building will be one job. (v) Panel recovery of double the quoted rate or Rs 2000 which is higher shall be recovered if contractor fails to attend the repair/ maintenance and testing on quarterly basis at due time.
Supply & fix in repair ionization smoke detector from shed with base plate complete with base plate complete all as specified and directed by Engr-in-Charge.
Supply & fix in repair heat detector in shed with base plate complete with base plate complete all as specified and directed by Engr-in-Charge.
Supply & fix in repair Beam detector with Reflectors range 15 mtr x 15 mtr x 60 mtr Operating voltage 24 VDC with adjustable convex mirror (all required Accessories.) Make : System Sensor / Honeywell / Fire Light / Notifier
Supply & fix in repair Conventional Manual call point. Make : spencer / Honeywell / Fire Light / NotiFier
Supply and lay in replacement of copper conductor armoured cable FRLSH of size 2 core x 1.5 Sqmm on wall / ground with necessary clamps complete all as specified and as directed by Engineer-in-Charge. Make : POLYCAB/ PLAZA/ HAVELLS.
Supply and lay in replacement of copper conductor armoured cable FRLSH of size 4 core x 2.5 Sqmm on wall / ground with necessary clamps complete all as specified and as directed by Engineer-in-Charge. Make : POLYCAB/ PLAZA/ HAVELLS.
Supply and fix in replacement of 12 Volts 7 Amps maintenance free dry cell battery, complete all as specified and as directed by Engineer-in-Charge. Make : EXIDE / AMCO / TATA GREEN.
Supply and lay in replacement of copper conductor PVC cable FRLSH of size 2 core x 2.5 Sqmm on wall / ground with necessary clamps complete all as specified and as directed by Engineer-in-Charge. Make : POLYCAB/ PLAZA/ HAVELLS.
S&F power backup system for starting of Generating set 180 AH, initial Chargered of 12 volts complete all as directed by Engineer-in-Charge. (Make:- EXIDE/Amron )
Taking down existing pipe supply and laying MS Pipe 'C' Class by of following bore all as specified and directed by Engr-in-Charge
200 mm bore
150 mm bore
100 mm bore
65 mm bore
50 mm bore
Note :- Cutting of exisitng pipe, welding works and inserting any type of fittings for above bore pipe deemend to including in quoted rates
Taking down existing union and supply and inserting GI union of 50mm bore all as specified and directed by Engr-in-Charge Note :- Cutting of exisitng pipe, welding works and inserting for fixing of gate valve deemend to including in above rates
Taking down existing gate valve and supply and fix gun metal gate valve of 50mm bore all as specified and directed by Engr-in-Charge Note :- Cutting of exisitng pipe, welding works and inserting for fixing of gate valve deemend to including in above rates
Taking down existing sluice valve and supply and fixe sluice valve PN 1.6 of following bore all as specified and directed by Engr-in-Charge
200 mm bore
150 mm bore
100 mm bore
Note :- Cutting of exisitng pipe, welding works and inserting any type of fittings for fixing of sluice valve deemend to including in above rates
Taking down existing foot valve and supply and fix CI foot valve of following bore all as specified and directed by Engr-in-Charge
100 mm bore
50 mm bore
Note :- Cutting of exisitng pipe, welding works and inserting any type of fittings for fixing of sluice valve deemend to including in above rates
Supply and fix solenoid Valve single port plensure operated 24 VDC coil Operated Size : 25mm one way Make : Rotex / HAWA / MARK Note :- Cutting of exisitng pipe, welding works and inserting any type of fittings for fixing of sluice valve deemend to including in above rates
Disconnection and removing of the unserviceable Electric motor and transporting the same to work shop for rewinding and re fixing the same in its original position after repairs, including testing and commissioning complete of following size and capacity all as secified and directed by Engr-in - Charge.
5 HP motor
12.5 HP Motor
40 HP motor
Supply and fix bearing suitable for following capacity motor all as specified and directed by Engr-in -Charge
Suitable for 5 HP motor
Suitable for12.5 HP Motor
Suitable for 75 HP motor
Suitable for 40 HP motor
Material and labour for CI special/fittings suitable for CI flanged/socket ends pipe upto 200mm bore such as bends, (any radius and angle), tapers any type (straight, bend, increasing, decreasing or double socket etc) tee piece, single branch 'Y' junctin, double branch, cross (all flanged), collars, caps & plug, tail pieces, reducers, mechanical joint etc complete including taking out old fittings complete all as specified and as directed.
Repair and Maintenance of Electric operated siren of range 3 to 5KM directly coupled with 3 HP 415 V 3 phase electric motor complete all as specified and directed by Engr -in-Charge . (Note Items such as PVC copper wire, lugs, thimbles, nuts, bolts, washer, PVC termination ,lath work if any are deemend to included in above rates). Note: rewinding shall be measured and paid separately
Re-winding of motor of Electric operated siren 3 HP with exisitng sizes/ guage copper wire , testing complete
Supply and fix Electric operated siren range not less than 5 KM
Supply and fix On / Off switches operating for siren
Supply and fix in repairs bearing of exisitng 3 HP motor
Servicing of Diesel Engine installed at P-4, P-6 and P-14 and taking out the defective/unserviceable parts and re-assembling the same after repair/replaced and testing complete all as specified and directed. (Note : U/S spare parts shall be measured and paid separately as supply only here in after).
Diesel filter exisitng size
Oil filter exisitng size
Air filter exisitng size
Fan belt exisitng size
Supply and pouring of coolant suitable for radiator as per the requirement of time to time as directed by Engr-in-charge for various capacities of DG Set
Supply and filling lubrication oil SAE-40 ( 20 W- 40 grade) of Make SERVO OF IOC/HINDUSTAN PETROLEUM/BPCL/ CASTROL) as approved by GE.
Supply and fix Battery Terminals (Positive and Negative - one set) copper 12V suitable for 100 / 120/ 180 AH as per existing complete all as specified and directed by Engr-in Charge.
Supply and fix Battery led (Positive and Negative - one set) copper not less than 1 meter with suitable for 180 AH as per existing complete all as specified and directed by Engr-in Charge..
Supply and filling distile water for exisitng power backup system all as specified and directed by Engr-in-Charge
M & L for painting complete equipments / machinery / pipes / valves / Elect Panels etc installed at pump house for P-1, P-6 and P-14 after prepation of old painted surface with two coat of exisiting colour synthetic enamelled paint complete all as specified and directed by Engr-in-Charge.
M & L for painting complete equipments / machinery / pipes / valves / Elect Panels etc installed at foam pump house of P-6 and P-14 after prepation of old painted surface with two coat of exisiting colour synthetic enamelled paint complete all as specified and directed by Engr-in-Charge.
Supply, Installation in repairsTesting & Commissioning of 8 Zone Microprocessor based conventional type Fire Alarm Panel incl following items
Panel indicator LCD.
Fault Indicator
Short Indicator
Zone Isolate Indicator
System Ok Indicator
Fire Indicator
Supply Fault Indicator
Panel fabricated of 16SWG CRCA Sheet Make : spencer / Honeywell / Fire Light / NotiFier
Supply and fix in replace of MCCB 3 Pole 100Amp 16kA 415V AC, 50 Hz into the existing panel board complete all as speciifed and directed by Engr-in-Charge. Make L&T/Havels/CG
Supply and fix in replace of MCCB 3 Pole 160 Amp 36kA 415V AC, 50 Hz into the existing panel board complete all as speciifed and directed by Engr-in-Charge. Make L&T/Havels/CG
Supply and fix in replace of MCCB 3 Pole 200Amp 36kA 415V AC, 50 Hz into the existing panel board complete all as speciifed and directed by Engr-in-Charge. Make L&T/Havels/CG
Supply and fix in repairs power contactor 3 Pole, 415 V, Current rating 70 A, 2NO + 2NC having coil voltage 240 Volts all as directed by Engineer-in-Charge.
Supply & fix in replace power contactor 3 Pole, 415 V, Current rating 110 Amps, 2NO + 2NC having coil voltage 240 Volts all as directed by Engineer-in-Charge. Make : L&T/Havels/CG.
Supply & fix in replace spare parts kit for 3 pole power contractor 45Amps, 415 volts, with coil rating 230/415 volts, type ML-3. make L&T/Havels/CG.
Supply & fix in replace spare parts kit for 3 pole power contractor 70Amps, 415 volts, with coil rating 230/415 volts, type ML-4. make L&T/Havels/CG.
Supply & fix in replace spare parts kit for 3 pole power contractor 110Amps, 415 volts, with coil rating 230/415 volts, type ML-6. make L&T/Havels/CG.
Supply and fix in replace Bimetalic Overload relays suitable for Power Contactor 40Amps, 415 volts, with coil rating 230/415 volts complete of make L&T/Havels/CG type ML-3.
Supply and fix in replace Bimetalic Overload relays suitable for Power Contactor 70Amps, 415 volts, with coil rating 230/415 volts complete of make L&T/Havels/CG .
Supply and fix in replace Digital Amp meter 96 mm X 96 mm flush secure Panel mounting type with suitable CTs - 01
Supply and fix in replace RYB neon indicating lamp set of three- 01
Supply and fix in replace from the exisitng panle single phase preventor all as specified and directed by Engr-in-Charge
Supply & Replace damaged / unserviceable inspection glass of 3 mm thick of size 20 cm X 20 cm suitable for hydrant box
M/s MM TRADERS
M/s Dara Constructions, Pulgaon
M/S L M Chourasia
MAHARASHTRA ENTERPRISES
RAJ ENTERPRISES
M/S JAI BHAWANI CONSTRUCTIONS
SHREE SIDDHIVINAYAK TRADERS
Bidder Name
M/S L M Chourasia
RAJ ENTERPRISES
SHREE SIDDHIVINAYAK TRADERS
MAHARASHTRA ENTERPRISES
M/s Dara Constructions, Pulgaon
M/S Maa Durga Constructions,Pulgaon
M/s MM TRADERS
M/S JAI BHAWANI CONSTRUCTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .