S.E. EDC-1 MORADABAD
MORADABAD
WORK OF LINE SHIFTING UNDER EDD 2 MORADABAD
2023_PVVNL_807476_2
16/2023-24/EDCIM
Open Tender
Electrical Works
Lump-sum
30 days
MORADABAD
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
S.E. EDC-1 MORADABAD
₹8,000
17 Jun 2023
7 Jun 2023
16 Jun 2023
7 Jun 2023
15 Jun 2023
7 Jun 2023
Amount
Safe carriage of the following material from Store Centre Majhola/JE's store to work site including loading and unloading at both ends :-
11 Mtr./8.5 Mtr. Long PCC/ST Poles.
ACSR Weasel/Dog Conductor.
LT A.B.C. Cable.
11 KV XLPE cable of size 3x70 sq.mm./ 3x120 sq.mm./ 3x185 sq.mm. etc.
Line material such as Cross-Arms, Pin Insulators, Guarding Angles, Guarding Wire, Disc Insulators and Cable Jointing Kits etc.
Dismantling of the line by :-
Removing of ACSR Weasel/Dog/XLPE conductor from all phases on line, making bundle and stacking at a safe place.
Uprooting of 11 Mtr./8.5 Mtr. Long PCC/ST Poles.
For 11 KV Line, Single support 11/8.5 Mtr. long ST/PCC Poles :- Excavation of foundation pit in size of 75x45 cm. having depth of 1/6th of the full length of the support (pole), providing and laying of stone pad (300x300x75mm.) in the bottom of the pit. Erection of support (pole) complete with fixing of 11 KV V-Type cross-arms and all other accessories by providing stone pad, cross arms, holding clamps, f-bracket and nuts & bolts etc. as per RESPO Norms.
For 11 KV Line, Double Pole structure with 11/8.5 Mtr. long ST/PCC Poles :- Excavation of foundation pit in size of 75x45 cm. having depth of 1/6th of the full length of the support (pole). Erection of support (pole) complete work by fixing of D.P. Clamps and all other accessories. The work includes fabrication work and fixing of cross bracing sets, cutting holes complete work as per RESPO Norms.
Grouting of Poles Single line support :- Grouting of support in CC 1:4:6 (cement, sand and 40 mm. brick ballast) Grouting will be done in the block of size 45cm x 45cm x 1/6th of full length of the support upto ground level as per RESPO Norms.
Grouting of stay rods (20x1800mm.) including all works of excavation, cement concrete in size of (0.60x0.60x0.30)M in the ratio of 1:4:6 (cement, sand and 40 mm. brick ballast) including back filling of soil and proper ramming etc.
Fixing, tightening and nozelling of stay wire with stay rod and stay insulators with the pole of required tension by providing stay clamps, nuts, bolts etc.
Earthing of support with MS Earth Rod of (20x2500)mm. long including excavation of pit and driving MS Rod 3.0M apart from support and 0.5M below the ground level and connecting below the earth electrodes with the help of G.I. Wire No.6 SWG tightening with nuts and bolts.
Laying, sagging, stringing and binding of ACSR Weasel/ Dog Conductor with all other accessories on pole as per RESPO Norms.
Laying, sagging, stringing and binding of ABC Conductor with all other accessories on pole as per RESPO Norms.
Laying of 11 KV XLPE Cable of size 3x70 sq.mm./ 3x120 sq.mm./ 3x185 sq.mm. and making connections as per RESPO Norms.
Filling and fixing of 11 KV outdoor/indoor type cable jointing kits as per RESPO Norms.
Dismounting of 63 KVA transformer from old double pole structure and mounting of same on new erected double pole structure complete work including making connection and other work.
Guarding of 11 KV Line with G.I. wire as per RESPO Norms.
Construction of plinth suitable for 160 kva transformer by providing all type of material. Complete work as per norms.
Installation of 160 KVA transformer on plinth , making connection and other work.
Providing and fixing of barbed wire on pole at standard height.
Mounting and fixing distribution box on double pole including making proper connections.
Carriage of following from work site to Store Centre Majhola including loading and unloading at both ends :-
13 Mtr./11 Mtr./9 Mtr. Long ST Poles.
ACSR Weasel/Dog Conductor/M.S. Scrap.
Singh Construction
M/S TRACKERS CONSTRUCTION
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .