Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.6 LAccepted-AOC | L1 | Accepted-AOC Quoted lowest and reasonable | |
| 2 | L2₹56.4 L+₹6.8 L (13.7%)Rejected-Finance 1ST FLOOR PRABHA SHOPPING COMPLEX OLD PAHARGAON DOLLYGUNJ PORT BLAIR SOUTH ANDAMAN ANDAMAN NICOBAR 744103 UDYAM AN 01 0000143 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L2 | Rejected-Finance Quoted high rate |
Tender Value
₹58.3 L
EMD Value
₹1.1 L
Closing Date
9 Nov 2024, 6:00 pmClosed
Col Alex Antony, CWE Port Blair
Commander Works Engineer, Military Engineer Services, Minniebay, Junglighat-Post, Port Blair 744 103
PROVN OF UNDERGROUND SUMP AND PUMP HOUSE FOR MARRIED ACCOMODATION AT PANCHU TIKREY UNDER GE (P) NORTH AT HUTBAY
2024_MES_676080_1
81090 Provn of UG Sump
Open Tender
Civil Works
Lump-sum
365 days
Port Blair
As per NIT
8 documents required · 8 mandatory
₹1,000
GE (P) North
₹1.1 L
Yes
1 Jul 2025
23 Sept 2024
16 Nov 2024
23 Sept 2024
9 Nov 2024
21 Oct 2024
Amount
SCHEDUEL 'A' PART- I TO XI NOTES: Schedule ‘A’ Part- I to X are prepriced by MES under Ser No. 1.00 to 10.00. Bidders shall insert their lump sum amount in the Green coloured field under Col-6 only.
Lump sum price worked out by the tenderer for "Building/Structures" as listed in Schedule 'A' Part-I
Lump sum price worked out by the tenderer for "Excavation, Earth work, site clearance and Land Development" as listed in Schedule 'A' Part-II
Lump sum price worked out by the tenderer for "Internal Electrification" as listed in Schedule ‘A’ Part-III
Lump sum price worked out by the tenderer for "Internal Water Supply" as listed in Schedule ‘A’ Part-IV
Lump sum price worked out by the tenderer for "External Water Supply" as listed in Schedule ‘A’ Part-V
Lump sum price worked out by the tenderer for "External Electrification" as listed in Schedule ‘A’ Part-VI
Lump sum price worked out by the tenderer for "Road, Hard standing, Path" as listed in Schedule ‘A’ Part-VII
Lump sum price worked out by the tenderer for "Sewage Disposal" as listed in Schedule ‘A’ Part-VIII
Lump sum price worked out by the tenderer for "Area Drainage" as listed in Schedule ‘A’ Part-IX
Lump sum price worked out by the tenderer for "PCC Retaining Wall" as listed in Schedule ‘A’ Part-X
Subtotal
NOTE: Schedule ‘A’ Part - XI is not prepriced by MES and prepriced rate indicated as 0.00 under Col.5 signifies this fact only. Bidder shall insert their rates in Green colour filled under Col-6.
SCHEDULE `A' PART - XI (MISC ITEMS)
External Water Supply
Supply, Installation, testing and commissioning of centrifugal pump set for head of 50m and discharge capacity of 450 LPM, 7.5HP, 3 Phase, 415 V electric driven 3000 rpm, horizontal suction, cast iron body with steel shaft including foundation as per the OEM recommendation complete all as specified and directed by Engineer-in-charge.
Supply and lay GI pipe "Medium Grade" 65mm dia including all fittings complete as specified and directed by Engineer-in-charge. (from existing sump to proposed sump)
S&F 80mm dia footvalve, Cast Iron conforming to IS 4038 including suitable flanges, bolts and nuts complete all as specified and directed by Engineer-in-charge.
S&F 80mm dia sluice valve , cast iron,screwed down high pressure with crutch and butterfly handle, screwed both ends for iron pipe or for unions and fixed with suitables reducers complete all as specified and directed
S&F 65mm dia sluice valve , cast iron,screwed down high pressure with crutch and butterfly handle, screwed both ends for iron pipe or for unions and fixed with suitables reducers complete all as specified and directed
Earthwork and Land Development
Supply only white moorum/approved earth obtained from location at Hutbay with a lead of 15kms to 25kms from Hutbay Jetty and transporting the same to CG land at Panchu Tikrey and Vijay Nagar OTM complex and stacking complete all as specified and directed.
External Electrification
Supply, install , testing and commissioning of CPRI approved indoor cubical type floor/wall mounted LT panel dust and vermin proof,IP-54 protection, made out of 2mm thick CRCA sheet. The Panel shall be suitable for 3 phase 4 wire system, 440V 50Hz bus bar of suitable size duly prewired for MCCBs and single core PVC insulated multi-stranded copper conductor 1100 volts grade of suitable size comprising of following items :- (a) MCCB 4 Pole 40 Amps, 415V of breaking capacity 25kA- 01 No (b) MCCB TP 25 Amps, 415V of breaking capacity 16kA- 02 Nos (c) MCB SPN 20 Amps 230V 10 kA - 1 No (Contd..../-)
(d) RYB Panel Indicators - 3 Nos (e) Digital Multifunction Meter - 1 No (f) S&F 7.5 HP motor starters - 02 Nos
Subtotal
Island Agency (BID ID -3151980)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .