| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.0 LAccepted-AOC 1 209 FIRST FLOOR SADAR BAZAR DELHI CANTT 1 209 FIRST FLOOR DELHI CANTT VASANT KUNJ SOUTH WEST DELHI DELHI 110010 | NEW DELHI | DELHI | 110010 | L1 | Accepted-AOC Accepted due to lowest rate quoted | |
| 2 | L2₹42.0 L+₹2.1 L (5.15%)Rejected-Finance H NO 425 WARD NO 4 BAHADURGARH ROAD MOHALLA RAM NAGAR NEAR MAIN GATE JHAJJAR 124103 HARYANA | JHAJJAR | JHAJJAR | HARYANA | 124103 | L2 | Rejected-Finance Rejected due to highest rate quoted | |
| 3 | L3₹44.7 L+₹4.8 L (11.9%)Rejected-Finance | L3 | Rejected-Finance Rejected due to highest rate quoted | |
| 4 | L4₹57.1 L+₹17.1 L (42.8%)Rejected-Finance RZ 17B STREET NO 30 INDIRA PARK PALAM COLONY NEW DELHI 110045 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110045 | L4 | Rejected-Finance Rejected due to highest rate quoted |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
7 Jul 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) GURGAON
GE (AF) GURGAON
CONSTRUCTION OF SINGLE LAB OF SIZE 7 X 10.6 MT AT PM SHRI KENDRIYA VIDYALAYA AT AFS RAJOKRI AND CONSTRUCTION OF ONE NEW LABORATORIES OF SIZE (10.60X7.0) MTRS IN PM SHRI KENDRIYA VIDYALAYA AT AFS BAWANA UNDER GE AF GURGAON
2025_MES_713311_1
GE/GUR-/NIT-22/2025-26
Open Tender
Civil Works
Item Rate
240 days
GE (AF) GURGAON
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) GURGAON
₹92,000
31 Jul 2025
9 Jun 2025
9 Jul 2025
9 Jun 2025
7 Jul 2025
23 Jun 2025
Amount
Surface dressing n.exc (not exceeding) 15 cm deep and getting out soft/loose soil.complete all as specified.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soft/loose soil complete all as specified.
All as per Srl Item No 2 here-in-before but depth exceeding 1.50m and not exceeding 3m. complete all as specified.
M&L for plain cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation, filling & mass concrete, sub base complete all as specified.
M&L for reinforced cement concrete (M-25) Design Mix using 20 mm graded stone aggregates as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified.
M&L for reinforced cement concrete (M-25) Design Mix using 20 mm graded stone aggregates as in Columns, pillars, piers, posts and struts complete all as specified.
M&L for reinforced cement concrete (M-25) Design Mix using 20 mm graded stone aggregates as in Slabs supported on walls,beams and columns in floors,roofs, complete all as specified.
M&L for reinforced cement concrete (M-25) Design Mix using 20 mm graded stone aggregates as in Beams, cantilevers, bressummers, lintel over 1.5 span complete all as specified.
M&L for providing reinforced cement concrete (M-25) Design Mix using 20 mm graded stone aggregates as in Chajjas complete all as specified.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter (rough finished surface) complete all as specified.
Formwork to sides of pillars,posts, struts, piers, columns and stanchions (square/rectangular/ polygonal) rough finished surface complete all as specified.
Formwork to soffits of suspended slabs such as roof slabs, floorslabs, landings and similar work not exceeding 200 mm thick rough finished in flat surface complete all as specified.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelvesincluding supports,overhangs,etc. also splays between floors in rough finished flat surfaces and etc complete all as specified.
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete rail ings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizon tal or sloping and similar work exc 10cm but n exc 20cm wide (rough finished surface) complete all as specified.
M&L for Mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips etc complete all as specified.
All as per item No.15 here-in-before but 6 mm dia to 8 mm dia
M&L for brick work with sub class 'B' brick, straight or curved on plan exc 6.0 mtr mean radius built in cement mortar 1:6 etc complete all as specified.
M&L for half brick work with sub class 'B' old size brick, straight or curved on plan exc 6.0 mtr mean radius built in cement mortar 1:4 etc complete all as specified.
M&L for rendering 15 mm thick in cement mortar (1:6) on brick work or concrete surfaces finished even and smooth (without using extra cement) complete all as specified.
M&L for 15 mm thick plastering in two layers (10+5) mm in cement mortar (1:4) on brick or concrete surfaces including rendering on fins, fascias, chajja, parapets etc and finishing the surfaces even and fair (without using extra cement), top layer shall be with WPC as per manufacturer's instruction and complete all as specified. Note: WPC shall be measured and paid separately.
M&L rendering 10mm thick in cement mortar (1:3) as in ceilings finished even and smooth (without using extra cement) complete all as specified.
Supply only intergral water proofing compound ISI Marked complete all as specified.
M&L for Hardcore (broken stone or boulders) of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete.
M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified.
M&L for 75 mm thick cement concrete (1:4:8) type D-2 (using 40 mm graded stone aggregates) as in sub base of flooing etc complete all as specified.
M&L for cement concrete (1:2:4) type B-0 (using 12.5 mm graded stone aggregates) 25 mm thick as in sub base of flooring/tiles etc complete all as specified.
M&L for screed bed or bedding layer of mortar 15 mm thick in cement mortar (1:4) for bedding of tiles complete all as specified.
M&L 10 mm thick rendering in cement mortar (1:3) on vertical surfaces for backing of tiles etc complete all as specified.
M&L for Coloured Vitrified Ceramic tiles 9-10 mm thick (Square/rectangular) of light Shade , polished, area of each tile not exceeding 0.36 sqm, fixed in floor/skirting etc over set and jointed in neat cement slurry and pointed in coloured cement to match with coloured tiles complete all as specified.
M&L 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, win dow-cills, cooking plat forms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admix ture of pigment to match with shade of granite complete all as specified.
Providing edge moulding to 18-20 mm thick stone(any description) of counters vanities etc, including machine polishing to edge to give high gloss finish etc. Complete to Granite stone any description.
M&L for PCC 1:2:4 type B1 (using 20mm graded stone aggregates) as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, coping, bed plates and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work, complete all as specified.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm thick with soft/loose soil etc complete all as specified.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified.
M&L for Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified.
M&L for Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified.
M&L for 15 mm thick plaster in cement mortar (1:4) mixed with water proofing compound on roof slabs finished even and smooth without using extra cement complete all as specified. Notes : WPC shall be measured and paid seperately.
M&L for water proofing treatment with APP (Atactic Polypropylene) modified polymeric prefabricated five layer membrane over roof consisting of cleaning of concrete or plaster surface of roof & parapet walls and applying evenly a bitumen primer confirming to IS 3488 @ 0.40 Kg per sqm laid using buten torch and sealing all joints of APP modified polymeric water proofing membrane minimum weight 3.6 kg/sqm reinforced with non woven polyester fabric (weight not less than 160 grams per sqm) unrolled and bonded to substrata with logitudinal and end laps 100 mm and 150 mm respectively as per manufacturer's instructions complete all as specified.
M&L for providing plain cement concrete (1:2:4) type B0 (using 12.5 mm graded crushed stone aggregate) as in coping or roof kerbs on roof chamfered on edge including trowelling slightly complete all as specified.
M&L for Cement concrete tiles 25cm x 25cm x 22 mm thick, machine pressed; set jointed and pointed in neat cement slurry in floors, and cut and polished, set with grey cement and pigments over 15mm thick cement screed bed in cement mortar 1:4 complete all as specified and directed.
M&L for providing 3mm thick wall care putty on wall before applying plastic emulsion paint and making the surface uniform all as specified. Note: plastic emulsion paint to be measured and paid saperately.
M&L for preparation of newly plastered surface of wall and applying two or more coat plastic emulsion paint, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification complete all as specified.
M&L for preparation of newly plastered surface of wall and applying two or more coat distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification complete all as specified.
M&L for preparation of newly plastered surface of ceiling and applying two or more coat distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification complete all as specified.
M&L for preparation of newly plastered surfaces of wall and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified.
S&F factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp ressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
S&F factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge.
S&F 100 mm Butt hinges, Stainless steel and fixed complete all as specified.
S&F 200mm long aluminium anodised, barrel tower bolts of extruded section complete all as specified.
S&F 150 mm size extruded aluminium alloy handles fabricated type anodised and fixed.
S&F 250 mm long aluminium alloy anodised sliding door bolts with hasp stapple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast sections or cast aluminium alloy complete all as specified.
S&F Aluminium (Die cast) body Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed.
M&L for preparation of new or previously untreated wooden surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified.
S&F window or ventilators section of frame 72x55mm fixed to wall or concrete surface with rowl plugs made of galvanised steel powder coated and section of shutter 47x20mm mulion section 72x50mm (Based steel as per IS 513 "D" quality galanised as per IS 277 with zinc of 120 gms/sqm) glazed or gauged and wire gauge shutter prepare to receive wire mesh to the shutter (Double door shutter) with total coated thickness of 0.6mm including grills/guard bars made of square bars powder coated fixed to window frame with screws including necessary fittings and all builders hardware such as handles, tower bolts and stays etc including 4 mm sheet glass in window & 4 mm frosted glass in vent alongwith 0.36mm nominal dia of wire and average width of aperture 1.40mm in mesh shutter complete all as specified and as directed. Make : NCL type-4000 Series or equivalent make specified in list of make.
Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement.
M&L for 18-20 mm thick Granite tiles machine cut , bedded and jointed with grey cements slurry and pointed with white or colour cement with admixture of pigment to match the shade of granite stone including grinding & polishing slab over screed bed or bedding layer of mortar 15 mm thick in cement mortar (1 : 4) laid complete all as specified.
M&L for 18-20 mm thick Granite tiles machine cut, in skirting/dado laid over cement mortar and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete over 10 mm thick rendering in cement mortar (1:4) on vertical surfaces for backing of tiles complete all as specified.
S&F 18 mm thick 100% solid WPC(wood Polymer Composite) plain board (minimum density 650 kg/Cum) fixed with screws, solvent cement/adhesive to make cupboard/kitchen cabinet sides top and bottom and shelves inside the cabinets complete all as specified and directed. Note: Material Testing Certificate(MTC) and authentication of the product shall be mandatory by the manufacturing company.
S&F18 mm thick 100% solid WPC(wood Polymer Composite) board (minimum density 650 kg/Cum) of one side Prelam /Rigidlam and other side balancing laminate colour to make cupboard/kitchen cabinet shutter/ drawer front shutters complete all s specified and directed.
S&F 12 mm thick 100% solid WPC(wood Polymer Composite) plain board (minimum density 650 kg/Cum) fixed with screws, solvent cement/adhesive to make wall mount kitchen cabinet back and pull out drawer sides complete all s specified and directed.
S&F 20 mm wide & 1 mm thick PVC edge bending of PVC pasted on edges with suitable adhesive, complete as specified and directed.
S&F auto closing hinges openable at 0 degree for kitchen cabinet shutters complete all as specified and directed.
S&F stainless steel handles 100 mm size for kitchen cabinet/cupboard shutters complete all as specified and directed..
S&F door magnet catcher with screw for kitchen cabinet/cupboard shutters complete all as specified and directed..
S&F sinks made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe,overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm including one number chromium plated waste fittings 40 mm dia & waste pipe complete all as specified and as directed.
S&F for rotational moulded polyethylene water storage tanks 500 ltrs capacity (cylinderical vertical with closed top) hoisted and fixed in position all as per SSR Part I complete all as specified.
S&F ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe of 20 mm bore and fixed, minimum weight of float valve 210 gms complete all as specified.
S&F 20 mm dia Gun metal gate valve with iron wheel head, screwed both ends for iron pipe complete all as specified.
Cutting chases, pinning in. making good to facings where required andpointing in cement mortar 1:3 to ends or edges of landings, steps, cills,sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth in brick wall etc complete all as specified.
S&F tubes medium grade galvanized with all fittings & fixed complete to walls & ceiling or laid in floors 15 mm dia bore pipe (including in short length) complete all as specified.
S&F bib taps long body, brass, fancy type, chromium plated with crutch or butterfly handles, screwed down, screwed for 15 mm bore GI pipe or for brass ferrule or to GI socket with water saving aerator complete all as specified.
S&F 15 mm dia angle valve, cast copper alloy screwed down high pressure, fancy type chromium plated screwed both ends for iron pipe or unions complete all as specified.
S&F PVC connection 450 mm long suitable for 15 mm GI pipe with two brass nuts & rubber washers complete all as specified.
S&F 50 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints including bend, tee, laid in trenches/ floors/walls complete.
S&F 75 mm dia PVC (SWR) pipes single socketed in any length with rubber rings joints laid in trenches or floor complete all as specified.
M&L PVC (SWR) 75 mm floor trap plain with grating including jointing with solvent cement complete all as specified.
S&F 75 mm dia PVC (SWR) bends with rubber rings joints fixed as required complete all as specified.
S&F Salt-glazed stoneware gully traps (150X150) mm, square or round mouthed, type 'P' complete all as specified.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out soft/loose soil.Complete all as specified
M&L 75 mm thick PCC 1:4:8 tybe D-2 using 40mm stone aggregate as in subbase.Complete all as specified
M&L for providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete.. Complete all as specified
M&L for providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete.
M&L prepration of new concrete surfaces of any description, not otherwise described, over 10cm width or girth & applying two coats of synthetic enamel paint over coat of primer complete all as specified
E/M SCHEDULE
M&L for point wiring with single core PVC insulated unsheathed 1100 volt grade cable with multi strand copper conductor of size 1.5 Sq mm FRLS (Nominal area) drawn through and including non metallic rigid PVC concealed conduit, medium grade, ISI marked not less than 20mm dia, concealed in wall, ceiling with GI saddles GI screws, rawl plugs (concealed conduit wiring) with all fittings including Tee, Junction boxes and provision of pressed steel terminal modular box with powder coated of 3.0 mm thickness for mounting switch/sockets and regulators and drawing continuous earth wire of PVC insulated unsheathed 1100 Volts grade cable with stranded copper conductor of size 1.5 Sq mm (Nominal area) complete all as specified. Note: Cost for cutting, chasing and making good to existing surfaces. Note :- Colour coding of cable should be Phase- Red, Neutral- Black and Earth- Green
(a) For one light point controlled by one SP switch
(b) For one ceiling fan/exhaust fan and wall mounted fan point controlled by one SP switch.
All as per item No- 85 above but for one 3 pin socket out let, 6 Amps on same board with the cable 1.5 Sqmm size.
All as per item No- 85 above but for one 3 pin socket out let, 6 Amps on Independent board with the cable 1.5 Sqmm size.
All as per item No 85 above but with 2.5 Sq mm cable for Independent board one 3 pin 15 Amps socket outlet including S/C 2.5 Sq mm PVC insulated copper conductor unsheathed 1100 v grade IS -694 FR LS cable for continuous earth wire connected to box of required size all as specified and directed by Engineer-in-Charge.
All as per above item No-85 here in before but using 4.0 sqmm single core multi stranded copper conductor PVC insulated and unsheathed, FRLS cable for 15 Amp socket outlet on independent board including 4.0 sqmm multi stranded copper conductor cable of green colour as continuous earth wire with lugs etc as required complete all as specified and as directed.
Supply and fix modular metal flush box ,1/2 module Complete all as specified and directed by Engineer-in-Charge.
Supply and fix modular metal flush box ,3 module Complete all as specified and directed by Engineer-in-Charge.
Supply and fix modular metal flush box ,6 module Complete all as specified and directed by Engineer-in-Charge.
Supply and fix modular metal flush box ,4 module Complete all as specified and directed by Engineer-in-Charge.
Supply and fix modular metal flush box ,8 module Complete all as specified and directed by Engineer-in-Charge.
S & F Modular switch 1 way 6A, 1 modules suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge.
S & F Modular Socket, 6A - 2/3 pin combined 2 module, suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge.
S&F Modular switch 1 way 16A, 1 modules suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge.
S & F Modular Socket, 16A - 2/3 pin combined 2 module, suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge.
Supply and fix Modular electronic Fan Regulator rotary flush step type 120 watt, 240 volt complete .
Supply and fix White cover plate with frame,1 module Complete all as specified and directed by Engineer-in-Charge.
Supply and fix White cover plate with frame,2 module Complete all as specified and directed by Engineer-in-Charge.
Supply and fix White cover plate with frame,3 module Complete all as specified and directed by Engineer-in-Charge.
Supply and fix White cover plate with frame,4 module Complete all as specified and directed by Engineer-in-Charge.
Supply and fix White cover plate with frame,6 module Complete all as specified and directed by Engineer-in-Charge.
Supply and fix White cover plate with frame,8 module Complete all as specified and directed by Engineer-in-Charge.
Supply and fix metal clad socket single pole and neutral sheet metal enclosure with and 20A earth plug and socket compete with one single pole MCB 20A 240 Volts all as specified and directed by Eng-in-Charge.
Supply and fixing of ceiling roses, surface bakelite 65x50mm 2 or 3 terminals , PVC/Polycarbonate, isolated body fixed on PVC round block complete all as specified and directed by Engineer-In- Charge.
Supply and fix LED lights fitting 1x 22W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed .
Supply and fixing LED security light fitting 35 watt high pressure dia cast aluminium housing and secondary optical lens for superior light distribution , heat resistant thoughened glass with frame, IP66 protection complete with lamp & connected item and connection with suitable cable from ceiling rose to light fitting and fixing on GI bracket made out of suaitable GI Pipe medium garde 1.2 mtr long bent to shape and fixed on wall with flat iron clamps, nuts bolts washer etc all as specified and directed. Havellls Cat No- ENDURACITYLITEPLAT PLUSSL35WLED757SASYBOPC or equivalent in from list of makes
S&F ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and as directed by Engr-in-Charge.
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm complete with making arrangement for fixing of exhaust fan on steel/Aluminium frame window/ making opening in brick wall as per site requirement and also making good to disturbed surfaces as per matching to existing complete all as specified and as directed by Engr-in-Charge
M & L for in replacement submain wiring with two run of 4.0 sqmm single core PVC insulated but unsheathed FRLS cable of specified size of multistranded copper conductor 1100 volts grade IS:694 marked and one run of 4.0 sqmm PVC insulated but unsheathed FRLS cable for earth continuty conductordrawn through and under suitable size of rigid non metallic PVC conduit , medium grade, ISI marked ( not less than 20 mm dia) complete with all acessories and fittings all laid/fixed concealed in wall/ceiling or surface in wall and surface conduit on ceiling, and also include the specified runs of specified size earth continuity conductor of similar type cable complete all as specified - Note:- Note: (i) Two runs of 4.0 sqmm cable and one run of 4.0 sqmm cable of earth continuity conductor and conduit shall be a unit length.
Supply and fixing triple pole distribution board (TPN DB) 'A' frame made out of CRCA sheet,double door, surface mounting TPN 4 way 415 volts 200 Amps rated bus bar and stove enamels dust and vermin proof suitable forTP/FP 'A' frame MCB for outgoing complete all as specified and as directed by Engineer-in-Charge. Indoasian Cat No- 811870 or equivalent in Havells/legrand. Note: MCB & TPN shall be measured and paid seperately.
M&L for earthing complete with GI earth plate electrode 60cmx60cmx6.3mm thick buried directly in ground (earth pit not less than 2.25 meter deep below normal ground level) with top edge of the plate not less than 1.5 meter below normal ground level, connected to and including galvanized iron strip 4 mm dia as earth lead by means of GI bolts, nuts, check nuts and washers earth pit surrounded by picked layer of coal dust and 15 mm thick mixture in equal ratio of magnesium sulphate & copper sulphate in all around bottom and top and watering pipe 20mm bore of GI medium grade with funnel all as shown in electrical plate NO 5 of SSR Part I (1991) and connecting to earthing test point, including CI cover, frame and PCC (1:3:6) type C-2 using 20mm graded stone aggregate as in earthing pit with CI cover and framing including necessary earth work etc, complete all as specified Note :- PCC chamber shall be constructed at least one meter away from building shall be provided in slanting manner. Note :- PCC pit cover shall be precast of RCC 1:2:4 type B-I 80 mm thick reinforced with XPM weighting not less than 4 Kg (sqm in lie of CI)
S&F MCB SP 6 to 32 Amps 10 KA, 240 volt 'C' Series all as specified and directed by engineer-in-charge.
S&F MCB TPN 63 Amps 10 KA, 240 volt 'B' Series all as specified and directed by engineer-in-charge.
S & F sub main wiring with PVC insulated, FRLS, unsheathed two single core cable 1100 volts grade with stranded copper conductor of size 2.5 sqmm (Nominal area) drawn in and including PVC conduit of suitable size as directed with and including one run of 2.5 sqmm multi stranded copper conductor single core PVC insulated, unsheathed cable of green colour as continuous earth wire including lugs etc connected and tested complete all as specified and as directed.Note: (i) Two runs of 2.5 sqmm cable and one run of 2.5 sqmm cable of earth continuity conductor and conduit shall be a unit length.
S & F sub main wiring with PVC insulated, FRLS, unsheathed two single core cable 1100 volts grade with stranded copper conductor of size 6.0 sqmm (Nominal area) drawn in and including PVC conduit of suitable size as directed with and including one run of 6.0 sqmm multi stranded copper conductor single core PVC insulated, unsheathed cable of green colour as continuous earth wire including lugs etc connected and tested complete all as specified and as directed.Note: (i) Two runs of 6.0 sqmm cable and one run of 6.0 sqmm cable of earth continuity conductor and conduit shall be a unit length.
S&F enviroment friendly indoor decorative 20 Watt LED polycarbonate Batten with opal diffuser , operating voltage range 140v to 270 V, Driver efficiency 88%, lumen efficiency =100 lm/watt , THD≤ 20 CRI>80 , colour temperature 6500 K, inbuilt surge protection = 2.5 Kv, isolation=3.75, and with zero mercury content including all accessaries all as specified and directed.
S&F of sheet metal enclosure double door concealed suitable for SPN distribution boards when MCB to be used having 200 Amp rated bus bar 8 ways 240 V including fixing in new location with connection of circuit and submain as per site requirement complete all as specified and as directed . Note- (a) MCBs are to be measured and paid seperately. (b)Make of MCBs and DB should be same.(c) Extra circuit length from DB to Switch borard shall deemed to be included in the quoted rate.
S&F in replacement MCB TPN 40 to 100 Amps, 415 volts, curve 'B', breaking capacity 10 KA, all as specified.
S&F in replacement MCB SPN 40 to 63 Amps, 240 volts, curve 'C', breaking capacity 10 KA, all as specified.
Supply and install hi wall split units weather control indoor/outdoor capacity of 1.5 TR, complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity 1.5 TR fitted on wall and out door to be fixing on roof/wall at requirement place including all necessary elecrical connections, bolting , nuts , clamping of 3 core copper cable, cooling tube , drain water pipe etc all as specified and directed by Engineer -in -Charge. Make : Voltas/Hitachi/Daikin or from the list of make
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4.0 KVA including fixing on wall and necessary electrical connections all as specified and directed by Engr-In-Charge. Make: Blue gurd/voline or from the list of make
Supply & Fix single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB 20-32 amps complete fixing on wall all as specified and directed by Engineer-in-charge Make : Havells/L&T/Standerd or from the list of make
M&L cross arms bracings suppots clamps and back plates fabricated from structural steel sections including nuts bolts washers welding bending cold or hold drilled holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat one under and one finished coat of paint for installation of condesning unit on the wall / ground complete all as specified and as directed by Engineer-in-charge
S&F Unplasticised PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc.,and as directed by Engineer-in-charge
M&L laying of copper tubing of dia 1/2" including insulation and brazing work complete all as specified and as directed by Engineer-in-charge.
M&L laying of copper tubing of dia 1/4" including insulation and brazing work complete all as specified and as directed by Engineer-in-charge.
Supply, & Fixing of 3 core flexible copper cable of size 4.0 Sq mm 1100 V grade complete fixing on wall by clamping/securing including connections all as specified and as directed by Engineer-in-charge.
Supply, laying, jointing and testing XLPE insulated, PVC outer sheathed, galvanised steel strips armoured, heavy duty power cable with aluminium conductor suitable for rated voltage of 1100 Volts grade earthed system and conforming to IS : 7098 of 1995 and of size 3.5 core X 35 Sqmm and laid in trenches/ducts/pipe or on poles complete all as specified and directed.
Supply , laying , jointing and testing XLPE armoured heavy duty electric able with aluminium conductor 1100 volts grade of size 25 Sq mm 3.5 Core complete all as directed.
Supply intallation commissioning and testing of outdoor LT Feeder pillar box size 600x600x450 mm and 3.15 mm thick CRCA Sheet weather and vermin proof CPRI approved with copper bus bar 400 Amps suitable for LT cable 1.1 KV 4 core of size upto 185 sqmm including provision of cable entries with glands locking arrangements and angle iron frame and legs of 90 cm long using 60x60x6 mm size MS angle iron fixed in floor in PCC 1:4:8 type D2 base of suitable size including neccessary excavation earth work complete all as specified and directed by Engr-in-charge.
M & L boring of holes under road pavment hard standing by trenchless technology using ultra sound technique and necessary machine incl HDPE pipe of 100 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed by Engr-in-charge.
M&L for earthing complete with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 Mtr below ground level) with top edge of earth plate not less than 1.5 Mtrs below ground level connected to GI strip of 25x4 mm size as earth lead by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, including PCC (concrete chamber) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire gauge mesh, 80 mm thick RCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) and specified including proviSI-on 20 mm dia medium grade pipe and watering pipe shall be 20mm bore medium grade, and including all excavation and earth work & connecting the earthing to an earthing test point complete all as specified & directed .
NOTE: (i) The concrete pit shall be PCC 1:3:6 type C-140 mm thick pre cast cover slab of RCC(1:2:4) type B-1 using 20 mm graded stone aggregate reinforced with 8 mm TMT bars @ 10 cm C/C on both SI-des with suitable cast iron handle shall be provided in lieu of cost iron cover shown in the electrical plate No.3 of MES SSR Part -1 (ii) item includes the cost of 7.5 m GI pipe for protection of GI srtip. (iii) PCC pits extra cost of addtional length of watering pipe,bends elbows etc.shall be deemed to be included in the quioted rate. (iv) Item includes the cost of 7.5 mtr length GI srtip of 25x4 mm size.
M&L for sand cushioning with a layer of sand 80mm thick before laying of cable and 150mm thick after laying of cable to trenches complete all as specified and directed
M&L for brick protection cover of UG cable by old size bricks common burnt clay building bricks sub class `B’ laid dry and flat abutting each other with width equal to length of brick and gap between adjacent brick not exceeding 10mm complete all as specified and directed
Nikunj Bansal Govt Contractor (BID ID -3341428)
JAIPAL AND BROTHERS (BID ID -3350226)
sumit associates (BID ID -3341089)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .