Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.8 LAccepted-AOC KATHARA DIST BOKARO 829116 | KATHARA | BOKARO | JHARKHAND | 829116 | L1 | Accepted-AOC AOC | |
| 2 | Rejected-Technical AT PO JARANGDIH BOKARO | JARANGDIH | BOKARO | JHARKHAND | - | Rejected-Technical Rejected as not L1 | |
| 3 | Rejected-Technical AT SAWANG GOMIA BOKARO JHARKHAND 829128 | BOKARO | BOKARO | JHARKHAND | 829128 | - | Rejected-Technical Rejected as not L1 |
Tender Value
₹3.3 L
EMD Value
₹4,200
Closing Date
25 Jun 2024, 4:00 pmClosed
Project Engineer (EnM), Kathara Colliery
Project Engineer (EnM), Office of the PO, Kathara Colliery
Re-Stringing cum replacement damage pole of LT overhead line 440V including replacement of conductor, brackets from to kathara work shop near washing plant at kathara colliery.
2024_CCL_310568_1
KTC/PE (EnM)/E-Tender/24-25/35
Open Tender
Electrical and Maintenance Works
Item Rate
10 days
Office of the Project Officer, PE (EnM), Kathara C
As per NIT
5 documents required · 5 mandatory
₹4,200
23 Aug 2024
15 Jun 2024
26 Jun 2024
17 Jun 2024
25 Jun 2024
17 Jun 2024
17 Jun 2024 - 22 Jun 2024
Amount
Supplying and erection of stay set complete ( galvanized with 19/20 mm diax1.8 M long stay rod, anchor plate of size 45 cmx45cmx7.5mm thhimble, stay, clamps, turn buckle (20mmx60cm)7/4.00mm dia G.I stay wire and strain insulator etc. in cement concrete 1:3:6 (1 cement: 3 coarse sand 6 graded stone aggregate 40 mm niminal size) foundation including excv & refilling et as required.
Erection of metallic pole of following length in cement concrete 1:3:6 ( I cement 3 sand 6 graded stone aggregate 4 nominal size) foundation including excavation & refilling etc as reqired.
Erection of ACSR Conductor of 7/3.35 mm diameter and above including binding etc. as required (06spnx50m x4wire)=1200mx0.394kg/m=472.80Kgx2% binding x2% sagging=492kg
Supplying channel iron (75mmx40mmx6mm) 7.14kg/mtr of pole top/straight two wires/ V shape angle iron/hannel iron, cross arm on steel tubular/PCC pole for 11/22/33KV as required
Erection of G.I wire no-8 SWG including binding etc as req(12spnx50mx0.13kg/m=78 kg)
Clamps, bolts nuts etc
Dismantling of over head lines comprising of copper/ aliminium over head conductor, G.I wire, cross arms insulator etc. as req. (6spnx50mx3 wire=1200mx0.394kh/m=473kg)
Dismantling of pole/streeet light stander/strut embedded in cement concerts foundation etc as required.
Cradling - Supply & erection of G.I wire 8 SWG including binding etc as required
Restriging ACSR conductor dog 7/1.96 mm to 7/3.10mm diameter including jamphering and sagging etc as required (7SPNx50Mx4wire)=1400mx0.394x0.394kg/mtr=kg+2% sagging+ 2% binding and jumphering=573 kg
Total impact of GST for the purpose of CTC
M/S TIGER ENTERPRISES
SEMCO ENGINEERING WORKS
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .