Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.2 LAccepted-AOC | L1 | Accepted-AOC Techno commercially qualified | |
| 2 | Rejected-Technical 159 KASIYADIH TANDWA CHATRA CHATRA JHARKHAND 825321 | CHATRA | JHARKHAND | 825321 | - | Rejected-Technical DOCUMENTS NOT VERIFIED | |
| 3 | Rejected-Technical GUNJARDIH BHANDARIDAH BOKARO JHARKHAND PIN NO 829132 | BOKARO | JHARKHAND | 829132 | - | Rejected-Technical DOCUMENTS NOT VERIFIED |
Tender Value
Refer Docs
EMD Value
₹2,500
Closing Date
27 Mar 2024, 12:00 pmClosed
AKHIL UJJWAL,PE(EnM),SDOCM
OFFICE OF THE PROJECT OFFICER,SDOCM,DHORI AREA,CCL
Fresh wiring of quarter No C-17 situated at G.M.Coloney, quarter No 1C/25 in Hospital Colony (Bokaro Colliery),Quarter No.C-11 Kalyani Colony and quarter No.MQ.251 Sharda Colony under SDOCM
2024_CCL_305413_4
SDOCM/PE(EnM)/NIT/23-24/32 dt.17.03.2024
Open Tender
Electrical and Maintenance Works
Item Wise
4 days
SDOCM
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,500
8 Apr 2024
18 Mar 2024
28 Mar 2024
18 Mar 2024
27 Mar 2024
18 Mar 2024
18 Mar 2024 - 27 Mar 2024
Amount
Fresh wiring of quarter No C-17 situated at G.M.Coloney under SDOCM
Wiring for light point/ fan point/ exhaust fan point/ call bell point with1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc.as required.Group A (Bulb point-15,Tube light point-10,Fan point-4,Call bel point-1,Exhaust point-2)
Providing and fixing following capacity TP&N disconnect or fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections etc. as required 32 Amp TP&N
Supplying and fixing following way, single pole and neutral,sheetsteel, MCB distribution board, 240 volts, on surface/ recess, Complete with tinned copper busbar, neutral bus bar,earth bar, dinbar, inter connections ,powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)2 + 4 way/ 6 way , Double door
Supplying and fixing 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections testing and commissioning etc. asrequired. Single pole and neutral
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required 2 x 4 sq. mm(for service wire)
Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.2 x 2.5 sq. mm
Supplying and fixing stepped type electronic fan regulator on the existing modular plates witch box including connections but excluding modular plate etc. as required
Supplying and fixing 3 pin,5 amp ceiling rose on the existing junction box/wooden block including connection etc as required
Supplying and fixing brass batten/ angle holder including connection etc. as required.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Providing and fixing 50 mm dia X 3.2 metres G.I. pipe (including accessories) complete with 50 mm X 50 mm X 6 mm angle iron bracket on wall and 75mm X 90mm shackle insulator with straps for house service connection including painting the angle and flat iron with primer and finish paint etc.as required
Fresh wiring of quarter No 1C/25 in Hospital Colony (Bokaro Colliery) under SDOCM
Wiring for light point/ fan point/ exhaust fan point/ call bell point with1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc.as required.Group A (Bulb point-6,Tube light point-4,Fan point-2,)
Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominalsize)onsurfaceorinrecesswithsuitablesizeofphenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (For light plugs to be used in non residentialbuildings).
Supplying and fixing metal box of 180mmX100mmX60mm deep(nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6&15/16 amps socket outlet and15/16amps piano type switch, connection, painting etc. as required.
Supplying and fixing following way, single pole and neutral,sheetsteel, MCB distribution board, 240 volts, on surface/ recess, Complete with tinned copper busbar, neutral bus bar,earth bar, dinbar, inter connections ,powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)2 + 4 way/ 6 way , Double door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections testing and commissioning etc. asrequired Single pole and neutral
Supplying and fixing stepped type electronic fan regulator on the existing modular plates witch box including connections but excluding modular plate etc. as required.
Providing and fixing following capacity TP&N disconnect or fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections etc. as required 32 Amp TP&N
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.2 x 6 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required 2 x 4 sq. mm
Supplying and fixing 3 pin,5 amp ceiling rose on the existing junction box/wooden block including connection etc as required.
Supplying and fixing brass batten/ angle holder including connection etc. as required.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Quarter No.C-11 Kalyani Colony and quarter No.MQ.251 Sharda Colony under SDOCM
Wiring for light point/ fan point/ exhaust fan point/ call bell point with1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc.as required.Group A (Bulb point-30,Tube light point-9,Fan point-8,,Exhaust fan-4,Call bel-1)
S/F power plug point piano type accessories supply and fixing metal box of 180 x 100 mm deep (nominal) size on surface or in recess with suitable size of phenolic laminated sheet cover in front inc. providing and fixing 6 pin 5/6 & 1515 amps socket outlet and 1516 amps piano type switch connection painting etc as required.
S/F power plug point modular type accessories supplying and fixing suitable size GI box with modular plate and cover in front on surface on in recess incl. providing and fixing 6 pin 15/16 & 5/6 amps modular socket outlet and 15/16 amps switch connection painting etc as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board 240 volts on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections powder painted including earthing etc. as required but without MCB by RCCB by isolator in4 way single door.
S/F ‘B’ series SP MCB: Supply and fixing 5 amps. To 32 Amps rating 240 Volts “C”series miniature circuit breaker suitable for lighting and other board loads of following poles on the existing MCB, DB complete connections testing and commissioning etc as required single pole & Natural .
Supply & fixing of electronic type regulator including connection etc. complete (Anchor or equivalent make).
GI earth pipe electrode with salt/charcoal Earthing with GI earth pipe 4.5 meters long 40mm dia incl. accessories and provided masonry enclosure with cover late having locking arrangement and watering pipe etc. with charcoal and salt as required.
Providing and fixing following capacity TP & N disconector fuse switchunit inside the existing panel board with ISI mark HRC fuse including drilling holes in cubical panel, making connection etc. is required. (32 Amp TP&N)
P/F house service connection:Providing and fixing 50mm diaX3.2 meter G.I. pipe (including accessories complete with 50 mm x 50 mm x 6 mm angle iron bracket on wall and 75 mm x 90 mm shackle insulator with satrap for house service connection including painting the angle and flat iron with primer and finish paint etc. as required.
GI wire 8 SWG + Erection of 8 SWG GI wire
Supply & providing 2 X 2.5 Sq.mm wire for wiring.
Supply & providing 7/20 wire for service connection.
Labor charge for fixing of 2 X2.5 Sq. mm & 7/20 wire.
Total impact of GST for the purpose of CTC
MAHTO ENTERPRISES
ARJUN ENTERPRISES
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .