| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.8 CrAccepted-AOC | ₹7.8 Cr | L1 | Accepted-AOC Being Lowest |
| 2 | L2₹8.0 Cr+₹17.1 L (2.19%)Rejected-Finance STREET NO 11 SECTOR NO 04 TILAK NAGAR SAGAR ROAD BIKANER RAJASTHAN 334001 | BIKANER | RAJASTHAN | 334001 | ₹8.0 Cr+₹17.1 L (2.19%) | L2 | Rejected-Finance Not Being Lowest |
| 3 | L3₹8.4 Cr+₹56.5 L (7.22%)Rejected-Finance KALU BASS SHRI DUNGARGARH BIKANER RAJASTHAN 331803 | BIKANER | BIKANER | RAJASTHAN | 331803 | ₹8.4 Cr+₹56.5 L (7.22%) | L3 | Rejected-Finance Not Being Lowest |
| 4 | L4₹8.5 Cr+₹70.6 L (9.03%)Rejected-Finance | ₹8.5 Cr+₹70.6 L (9.03%) | L4 | Rejected-Finance Not Being Lowest |
| 5 | L5₹8.9 Cr+₹1.1 Cr (14.0%)Rejected-Finance HOUSE NO 769 SOUTH CIVIL LINES MUZAFFARNAGAR UP 241001 | HARDOI | UTTAR PRADESH | 241001 | ₹8.9 Cr+₹1.1 Cr (14.0%) | L5 | Rejected-Finance Not Being Lowest |
Tender Value
₹8.0 Cr
EMD Value
₹7.2 L
Closing Date
24 Apr 2023, 6:00 pmClosed
CE Bathinda Zone
HQ Chief Engineer Bathinda Zone Bathinda Mil Stn - 151004
PROVN OF KLP ACCN AT BIKANER MIL STATION
2023_MES_579995_1
CE BTZ/BKN/TOKEN-29 OF 2022-23
Open Tender
Civil Works
Lump-sum
730 days
GE (P) Bikaner
As per NIT
10 documents required · 10 mandatory
₹3,000
GE (P) Bikaner
₹7.2 L
Yes
17 May 2023
9 Feb 2023
26 Apr 2023
9 Feb 2023
24 Apr 2023
12 Apr 2023
Amount
Lump sum price worked out by the tenderer for “BUILDING /STRUCTURE WORKS" as listed in Schedule ‘A’ Section - I
Lump sum price worked out by the tenderer for “INTERNAL ELECTRIFICATION WORKS" as listed in Schedule ‘A’ Section - II (Part-I)
Sch 'A' Sec - II (Part-II), (INTERNAL ELECTRIFICATION WORKS)
Supply and hanging /fixing ceiling fan 1200 mm sweep AC Supply (Input Voltage Range ; 120 to 280V), BLDC type, 5 star rated, BEE and ISI Marked super enamelled, copper winding of 'B' class insulation, single phase, minimum 30W (± 10%), Temperature rise 40 degree maximum without remote with and including capacitive fanregulator, 03 No blades, down rod including accessories, white colour, total harmonic less than 10%, 5 speed, hanging in position including making connection with flexible cord three core twisted copper conductor of suitable size from ceiling rose to fan complete all as specified. Note :- Serial Number as issued by Engr-In-Charge of celing fan and GE Office name shall also be written on fan with red colour permanent marker and fixing of regulator on switch board, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account
Supply and fixing MCB 240 volts AC supply, SPN with over load and short circuit protection and rupturing capacity not less than 10 KA , 'C' Curve 25 Amps complete all as specified.
Supply and fixing MCB 240 volts AC supply, SPN with over load and short circuit protection and rupturing capacity not less than 10 KA , 'C' Curve 16 Amps complete all as specified.
Supply and fixing MCB 240 volts AC supply, SPN with over load and short circuit protection and rupturing capacity not less than 10 KA , 'C' Curve 10 Amps complete all as specified.
Supply and fixing blanking plate suitable for any type of DB etc complete all as specified and as directed by Engineer-in-charge.
Supply and fixing LED complete fitting batten and rod, T-8 Retro LED tube polycarbonate housing 1 x 20 Watt, appx 4 feet long, with decorative box linear LED lighting fixture with CRCA housing environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to tube fitting, complete fitting with all accessories and following specifications, including taking down old unserviceable light fitting any type complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts. (c) Temp operating range : Minus 5°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Current THD Max10% and voltage THD max 5% (f) IP rating : IP-20. (g) CRCA pre coated housing with coloured plastic end cap. (h) LED Driver of the same make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection minimum 2.5 kV. (l) CCT : Minimum 6000K (m) CRI : Minimum 80 (n) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
Supply and fixing LED light fitting 1 x 10 Watt, appx 2 feet long with decorative ultra ceiling square profile linear LED lighting fixture with extruded polycarbonate environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to light fitting, complete fitting with all accessories and following specifications, including taking down old Unserviceable light fitting any type complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 5°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Current THD Max10% and voltage THD max 5% (f) IP rating : IP-20. (g) CRCA pre coated housing with plastic end cap. (h) LED Driver of the same make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection minimum 2.5 kV. (l) CCT : Minimum 6000K (m) CRI : Minimum 80 (n) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
Supply and fixing LED bulb 1 X 9 W having Lumens efficiency , BEE rated 3 star LED lamps etc complete all as specified and directed by Engr - in charge.
Supply and fixing energy efficient LED security light fitting of 25W pressure die cast aluminium housing/body, heat resistant clear toughened glass, better optics for uniform distribution street luminaire, with driver, including electric connection, fixing the light fitting with new bracket made out of GI tubing light grade 25mm dia, 1 metre long bent to shape at 120 degree angle at half metre from bottom, including two Nos clamps made out of MS Flat iron size 40x3 mm with suitable nuts and bolts for fixing of bracket including painting to MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer, complete fitting with all accessories and following specifications, including taking down old unserviceable light fitting with old bracket any type complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) IP rating : IP66. (g) IK rating : Minimum IK07 (h) Built in potted LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection 10 kV (inbuilt + extended) (l) CCT : 5700 K. (m) CRI : Minimum 70 (n) Lens - High Efficiency wide angle lens. (o) BIS Approved fixtures and driver (p) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
Supply and fixing distribution board (concealed flush to wall) 4 way VTPN Double door for mounting MCCB & MCBs factory made confirming to IS-13032, fabricated out in CRCA sheet not less than 1.20 mm thick, fitted with DIN Channel neutral link and 250 Amps rated bus bar, DBs shall be semi glossy finished with epoxy polyster based power paint sprayed and braked at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DBs shall be double door type with hinged door with locking arrangement, The DBs shall be provided with label marking indicating the incoming and outgoing circuits on all ways as specified and directed by Engineer-in-Charge
Material and labour for concealed wiring for telephone connection complete with PVC insulated sheathed cable with copper conductor having single strand of 0.4 mm dia two pair taped for telephone wiring drawn through and including PVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed. (Telephone connection socket outlet and terminal box shall be measured and paid separately under appropriate item of BOQ).
Material and labour for concealed wiring for TV antenna connection complete with coaxial RG-6 heavy duty PVC insulated sheathed cable with copper conductor having single strand of 0.7 mm dia and a aluminium wire net drawn through and including PVC conduit 25mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed. (TV antenna connection socket outlet, terminal box shall be measured and paid separately under appropriate item of BOQ).
Subtotal
Lump sum price worked out by the tenderer for “INTERNAL WATER SUPPLY WORKS" as listed in Schedule ‘A’ Section - III (Part-I)
Sch 'A' Sec - III (Part-II), (INTERNAL WATER SUPPLY WORKS)
Supply and fixing 15mm bore two-way angle cock with flange chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed for iron pipe or for unions etc complete all as specified and directed by Engr - in charge.
Supply and fixing health faucet brass chromium plated with SS tube 1 Mtr length with hook etc complete all as specified and directed by Engr - in charge.
Subtotal
Lump sum price worked out by the tenderer for “ROAD, PATH & CULVERT WORK" as listed in Schedule ‘A’ Section -IV (Part-I)
Sch 'A' Sec - IV(Part-II), (“ROAD, PATH & CULVERT WORK")
Material & labour Continuous Jodhpur stone slab edging 7.5 cm thick to 10 cm thick ,30 cm to 35cm wide and 30cm to 45 cm long,dressed so that the maximum depression from a straight edge held against the dressed surface shall not exceed 6mm for top and exposed surfaces of sides and 20mm for the rest of surfaces jointed in cement mortar 1:6 and struck flush, including necessary earth work, embedding to depth as required and tamping around edging and removal of surplus spoil to a distance not exceeding 50 meter and deposited as directed complete all as specified.
Supply and fixing cat eye reflective type of metal body alloy of size 100mmx 100mm x 20 mm, with PAMA strip lens reflector of Model No DA 942.0 fixed with and including MS stud of suitable size as per manufacturer's instructions complete all as specified and as directed.
Material and labour for Thermo plastic paint road marking 2mm thick painting (lines, dashes, arrows, letters etc) with road safety spikeries glass beads including preparation of new or previously treated road surfaces and applying paint by using special applicator machine with heating arrangement complete all as specified and as directed.
Material and labour for machine pressed precast conctete interlocking paver block rubber moulded any shape and size with grey cement and with pigment confirming to IS 15658-2006 of 80 mm thickness M-40 Grade.etc complete all as specified and as directed., prepolished & preglazed, shape haxagon / trigular / zigzag / I-shaped etc, as directed, confirming to relevant IS, having compressive strength not less than 400 Kg/ Sqcm, laid over and including 25mm thick layer of sand cushining and filling the interstices etc with sand complete all as specified and as directed.
Subtotal
Lump sum price worked out by the tenderer for “AREA DRAINAGE WORK)" as listed in Schedule ‘A’ Section -V
Lump sum price worked out by the tenderer for “SEWAGE DISPOSAL WORK" as listed in Schedule ‘A’ Section - VI (Part-I)
Sch 'A' Sec - VI (Part-II), (SEWAGE DISPOSAL WORK)
Supply and laying DWCPE (SN8) drain pipes 150mm nominal dia as per IS-16098 (Part-II), laid in trenches to required slope, including all accessories/fittings/jointing ring, jointing and testing complete all as specified and as directed by Engineer-in-Charge. Note : Excavation, earth work and pedestal /anchorage if required shall be measured & paid separately under appropriate item of BOQ/Sch A.
Subtotal
Lump sum price worked out by the tenderer for “SECURITY FENCING AND COMPOUND WALL WORKS" as listed in Schedule ‘A’ Section - VII
Lump sum price worked out by the tenderer for “EXTERNAL WATER SUPPLY WORKS" as listed in Schedule ‘A’ Section - VIII (Part-I)
Sch 'A' Sec - VIII (Part-II), (EXTERNAL WATER SUPPLY WORKS)
Supplying, laying, jointing and testing Ductile iron pipe (ISI marked) class K-7, bore 100mm, confirming to IS : 8329-2K, spigot & socketed ends centrifugally cast, with cement mortar lining inside and metallic zinc coating with finishing layer of bituminous paint on outside the pipe, suitable for and including rubber tyton joints (Push-on joint) complete all as specified and as directed. Note : (i) Earth work, DI specials/ fittings shall be measured and paid separetly. (ii) Test Certificate for pipes from manufacturer shall be produced. No payment shall be entertained without Test Certificate.
Supply and fixing cast iron sluice valve 100 mm dia with flanged ends class I PN 1.0 (heavy duty ISI marked) confirming to IS:14846-2000, drilled type, steel spindle, CI gate with brass ring, iron wheel handle, suitable for CI/DI pipe line, complete including jointing material such as nuts, bolts, washers and rubber sheet insertion 3.0mm thick at both ends etc complete all as specified and as directed.
Material and labour for Cutting of existing CI/DI pipes line 200mm bore for inserting and including tee of size 200x200x100mm for taping in trenches including run lead joint complete all as specified and as directed. NOTE:- Necessary earth work, CI fitting/lead joints etc reqd to complete the job deemed to be included in the quoted rate.
Material and labour for Construction of brick masonary valve pit chamber size 100 X100 X100 cm (internal dimension) using sub class 'B' bricks complete including excavation & earth work, returning fillig and disposal of surplus soil to distance not exceeding 50m and deposited where directed, PCC (1:3:6) type C-2 using 40 mm graded stone aggregate in foundation, coping on top in PCC (1:2:4) type B-1 using 20 mm graded stone aggregate, brick work in cement mortar (1:4), inner plaster 12 mm thick in cm (1:3) finished even and smooth and pointing flush externally as the work proceeds in the same mortar, MS sheet cover 3.15mm thick mounted on angle iron frame of size 40 x 40 x 6mm with handle and locking arrangement duly painted with two coats of synthetic enamel paint over a coat of red oxide primer and embedded portion of MS work duly applying black bitumenous paint before embedded complete all as specified and as directed.
Material and labour for Construction of brick masonary valve pit chamber size 45cm X45cm X60 cm (internal dimension) using sub class 'B' bricks complete including excavation & earth work, returning fillig and disposal of surplus soil to distance not exceeding 50m and deposited where directed, PCC (1:3:6) type C-2 using 40 mm graded stone aggregate in foundation, coping on top in PCC (1:2:4) type B-1 using 20 mm graded stone aggregate, brick work in cement mortar (1:4), inner plaster 12 mm thick in cm (1:3) finished even and smooth and pointing flush externally as the work proceeds in the same mortar, MS sheet cover 3.15mm thick mounted on angle iron frame of size 40 x 40 x 6mm with handle and locking arrangement duly painted with two coats of synthetic enamel paint over a coat of red oxide primer and embedded portion of MS work duly applying black bitumenous paint before embedded complete all as specified and as directed.
Material for Cutting/dismantling of PCC hardstanding/WBM road with soiling & premix carpet of any description for laying of arboriculture water distribution pipe lines and disposl of removal matrieal to a distance exc 250m but not exc 500m and making good the same with & including black top of surface dressing renewal coat by spraying evenly paving bitumen at 12 kg per 10 sqm chipping @ 0.10 cum per 10 sqm and rolling to required gradient and camber complete all as specified and as directed.
Subtotal
Lump sum price worked out by the tenderer for “EXTERNAL ELECTRIFICATION WORKS" as listed in Schedule ‘A’ Section - IX (Part-I)
Sch 'A' Sec - IX (Part-II), (EXTERNAL ELECTRIFICATION WORKS)
Supply and fixing energy efficient LED street light fitting of 45W pressure die cast aluminium housing/body, heat resistant clear toughened glass, better optics for uniform distribution street/Roadway luminaire, with driver, fixing the light fitting with new bracket made out of GI tubing light grade 32mm dia, 1.2 metre long bent to shape at 120 degree angle at half metre from bottom, including two Nos clamps made out of MS Flat iron size 25x4 mm with suitable nuts and bolts for fixing of bracket including painting to MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer, including electric connection, complete fitting with all accessories and following specifications, including taking down old unserviceable light fitting any type with old bracket complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 105 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) IP rating : Minimum IP65. (g) IK rating : Minimum IK07 (h) Built in potted LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection 10 kV (inbuilt + extended) (l) CCT : 5700 K. (m) CRI : Morethan 70 (n) Lens - High Efficiency wide angle lens. (o) BIS Approved fixtures and driver (p) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
Supply and fixing LED Post Top light fitting of 25W decorative design, Glare-free and better uniformity compete fitting all with accessories and LED lamp, fixing on 50mm GI pipe system or as directed by Engr-in-Charge incl making electric connection, with suitable size of flexible copper wire 3 core from junction box to light fitting complete fitting with all accessories and following specification and all as directed by Engr-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) CRI : Morethan 70 and CCT : 5700 K. (g) IP rating : IP66. (h) IK rating : Minimum IK07 (j) Built in potted LED Driver of the make as of the luminaire. (k) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (l) Surge protection 10 kV (inbuilt + extended) (m) Lens - High Efficiency wide angle lens. (n) BIS Approved fixtures and driver (o) Rated life time : 50000 burning hrs (Average 10 to 12 hrs daily)
Note for Sl No. 47.00 to 48.00:- (a) Tenderer shall submit test report of LED street light fitting & LED post top lantern light fitting from Government accredited test laboratory for LM - 79 and LM - 80. (b) Contractor has to furnish a replacement warranty of 05 years for LED light fittings complete including lamps from the date of completion of CA. The product will be replaced free of cost in the following case :- (i) Manufacturing defects. (ii) Failure due to mechanical and electrical impact. (iii) Drop in lumen (or lux at 1m) below 90% of claimed values of lumen(or lux at 1 m) of the LED /Luminaries. (c) All LED light/luminare must meet the provision laid down in IS - 16101, 16102 Part -I/II,16103 Part -I, 16104,16105,16106, 16108/2012 and 15885 Part -II / Section 13. (d) Scope of work shall include LED street light fitting & LED post top lantern fitting walls/building which includes needful T & P and required accessories etc if any, complete including making connection, testing etc complete. No extra payment is admissible on these account.
Supply and fixing of junction box of size 200mmx160mmx110mm or any other higher size (pole mounting) and should be insulated and made out of polycarbonate with glass fiber reinforeced material having IP 65 protection in accordance with IEC 60259, fixing with and including SS 304 clamp made out size 25x3 mm including suitable size of nuts, bolts and washers complete comprising of the following and as directed by Engineer-in-Charge :- Note : (a) Junction Box must meet the provision laid down in IEC-60998-1, IEC-60695-2, IEC-60670-22 to 5 and color according to RAL - 9011/7035/7035. (b) The manufacturer of junction box shall submit a copy of IEC certificate. (c) Junction box shall be fire retardant and self extinguishing in accordance with IEC-60695-2 to 11, DIN VDE 0304 Part-3, UL94 V-2 flammability standard., it should be tested as Glow Wire test for 960*C (d) The degree of protection of enclosure against mechanical load shall be in accordance with EN 50298 for IK08 (e) Internally embedded gasket of polyurethane/extruded silicon gasket. (f) Junction box shall be with 4 pole complete with single pole MCB 'C' curve of 6 Amp rating.
Supply, installing, commissioning and testing time switch astro type having longitude and latitude of phase of 32 Amps rating with contactor fitted inside steel enclosure complete all as specified and directed.
Cable route / path indicators made out of 40x40x4mm angle iron 1.2 mtr long and plate of size 100mmx150mmx6mm welded only on one side end havinng embossed on plate as cable HT including PCC (1:4:8) of size 30cmx30cmx 30cm duly embedded the angle iron in PCC including excavation / earth work and form work etc complete all as specified and directed by Engineer-in-Charge.
M & L for boring of holes under main road pavment,hard standing by trenchless technology using ultra sound tecnique and necessary machine for accomodet 100mm bore GI tube (light grade) in the drilled holes,returning ,filling in the end working space including removal of surplus soil and making good the surface. Note : (GI pipe light grade shall be measured and paid separately) (ii) Actual length of road/ hard standing/ path shall be measured for payment purpose.
Subtotal
Lump sum price worked out by the tenderer for “SUMMER APPLIANCES WORKS" as listed in Schedule ‘A’ Section - X (Part-I)
Sch 'A' Sec - X (Part-II), (SUMMER APPLIANCES WORKS)
Supply and Installation of Desert cooler electric driven single phase 230 volts steel body having nominal air flow capacity of 4000 Cum per hours factory made GI sheet body 18 SWG and side panells of 22 SWG, water sump capacity not less than 40 ltrs, including water pump submesible type of suitable capacity ISI marked, with and including of fixing float valve of size 15 mm dia , PVC connection of suitable size and GI union of same size, complete including electric connection complete all as specified and as directed. Note (a) : Sufficient length of 3 core PVC sheathed round copper cable size 23/.0076 to enable fixing in to plug point shall be provided by contractor. (b) Arrangement of power connections and water connections to the desert cooler will be included in installation. (c) No extra payment shall be made for float valve, nut, wahser PVC connection, leakproof joints etc and making connection from GI pipe 15 mm dia to desert cooler in this regards, union for GI pipe ball valves brass complete (d) GI Pipes shall be measured and paid seperately under respective item.
Supply & installing of Voltage stabilizer for automatic operation having input & output voltage, Amps, Over & low voltage cutout and timer delay function etc digital display single phase naturally air cooled indoor type & designed for input variation between 170 V to 280 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 1 KVA with wall mounting bracket complete all as specified and as directed.
Supply & installing of Voltage stabilizer for automatic operation having input & output voltage, Amps, Over & low voltage cutout and timer delay function etc digital display single phase naturally air cooled indoor type & designed for input variation between 170 V to 280 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 2 KVA with wall mounting bracket complete all as specified and as directed.
Supply, installation, commissioning and testing of water cooler Electric driven (Single) phase having approx storage capacity of 120 ltr and nominal cooling capacity of 60 ltrs per hour including electric connection complete all as specified and directed by Engineer-in-charge.
Supply, installation, commissioning and testing of water cooler Electric driven (Single) phase having approx storage capacity of 80 ltr and nominal cooling capacity of 40 ltrs per hour including electric connection complete all as specified and directed by Engineer-in-charge.
Subtotal
Lump sum price worked out by the tenderer for “SOLAR WATER HEATER AND CENTRALISED HOT WATER SUPPLY WORK" as listed in Schedule ‘A’ Section - XI (Part I)
Sch 'A' Sec - VIII (Part-II), (“SOLAR WATER HEATER AND CENTRALISED HOT WATER SUPPLY WORK")
Supply and fix electric water heater, storage type ABS body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, suitable PVC connection for HOT and COLD water length not less than 450mm etc. complete all as specified and as directed
Sch 'A' Sec - XI (Part-II), (SOLAR WATER HEATER AND CENTRALISED HOT WATER SUPPLY WORK)
(c) Provisions of electrical backup with min 3 KW heating element - one job solar water heating system shall be provided on roof of single/double storey building the electrical backup connection shall be tapped from sub main board provided at ground floor. (d) Heat exchanger shall be cage type and made of stainless steel tube of grade 04 Cr 198 NI or 0718 NI of IS 1570 (Part-2) 1985. (e) All other pipe/civil work, steel staging work for PVC tank, electrical work, outlet and inlet thermometer,air release valves, check valves, gate valves, float valves/controls and instruments etc. All as required shall be deemed to be included in unit rate quoted by the contractor for this item, System internal piping shall be ISI marked GI pipe medium class of IS 1239 duly insulated with 50 mm thick rock wool of 48 Kg/M3 density and 26 SWG AI Cladding. (f) Note : (i) The system shall be tested on completion to ensure that 200 ltrs of water at 65 degree centigrade is available in hot water tank on a normal day in cold season. (ii) General Purpose rotational moulded PVC/Syntex overhead tank of capacity 500 ltrs for each system with inlet and outlet shall be provided at roof 3M above roof level complete with necessary stagging with MS work as per recommendation of manufacturer and with provn of suitable size float valves deemed to be included in quoted rates. (iii) Normal water pipes and accessories from the normal overhead water tank to inlet of both make up water tank and plate colletor shall be included in the quoted rates only. Similarly hot water pipes from hot water storage tank to bathrooms/kitchen shall be measured and paid for separately. (PVC tank 500 ltr capacity to be measured and paid separately)
400 mm thermal grade PU insulation with FRP Cladding Tank stand assembly shall be made of size 38 x 38 x 4 mm duly pre-treated and stove enamelled with black colour paint. (c) Provisons of electrical backup with min 3 KW heating element - one job solar water heating system shall be provided on roof of single/double storey building the electrical backup connection shall be tapped from sub main board provided at ground floor. (d) Heat exhanger shall be cage type and made of stainless steel tube of grade 04 Cr 198 NI or 0718 NI of IS 1570 (Part-2) 1985. (e) All other pipe/civil work, steel staging work for PVC tank, electical work, outlet and inlet thermometer, air release valves, check valves, gate valves, float valves/lcontrols and instruments etc. All as required shall be deemed to be included in unit rate quoted by the contractor for this item, System internal piping shall be ISI marked GI pipe medium class of IS 1239 duly insulated with 50 mm thick rock wool of 48 Kg/M3 density and 26 SWG AI Cladding. (f) Note : (i) The system shall be tested on completion to ensure that 300 ltrs of water at 65 degree centigrade is available in hot water tank on a normal day in cold season. (ii) Genral Purpose rotational moulded PVC/Syntex overhead tank of capacity 500 ltrs for each system with inlet and outlet shall be provided at roof 3M above roof level complete with necessary stagging with MS work as per recommendation of manufacturer and provn of float valve of suitable size shall be deemed to be included in quoted rates (iii) Normal water pipes and accesories from the normal overhead water tank to inlet of both make up water tank and plate collector shall be included in the quoted rates only. Similarly hot water pipes from hot water storage tank to bathroom/kitchen shall be measured and paid for separately. (PVC tank 500 ltr cap to be measured and paid separately)
M&L hot water GI pipe 20 mm bore ISI marked with all fitting medium grade with rock wool insulation fixed with chicken wire mesh including with alluminium sheet etc complete all as specified and as directed by Engineer-in-charge.
M&L hot water GI pipe 15 mm bore ISI marked with all fitting medium grade with rock wool insulation fixed with chicken wire mesh including with alluminium sheet etc complete all as specified and as directed by Engineer-in-charge.
Subtotal
Lump sum price worked out by the tenderer for “EXCAVATION, EARTHWORK AND SITE CLEARANCE DEVELOPMENT WORK" as listed in Schedule ‘A’ Section - XII
Jasraj & Company
M/s R L PAREEK
Onkar Nath Bhalla And Sons Contractor Pvt. Ltd.
M/s Arihant Builders
A S CONSTRUCTION COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .