Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.7 LAccepted-AOC 67 A HAFIZALI BAHADUR KHAN MARG SURAJI COMPOUND BEHIND KHATAU MILL BYCULLA W MUMBAI 400011 BRITE INDUSTRIES 67 A HAFIZALI BAHADUR KHAN MARG SURYAJI COMPOUND BEHIND KHATAU MILL MUMBAI | MUMBAI | MAHARASHTRA | 400011 | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹18.7 L+₹3.0 L (19.1%)Rejected-Finance 5 31 EWS PREETAM NAGAR ALLAHABAD 211011 | ALLAHABAD | ALLAHABAD | UTTAR PRADESH | 211011 | L2 | Rejected-Finance Highest bidder | |
| 3 | L3₹23.4 L+₹7.7 L (49.0%)Rejected-Finance 26M NEEM SARAI DHOOMANGANJ PRAYAGRAJ 211011 | PRAYAGRAJ | UTTAR PRADESH | 211011 | L3 | Rejected-Finance Highest bidder | |
| 4 | Rejected-Technical | - | Rejected-Technical Not enlisted in approprite category | |
| 5 | Rejected-Technical 83 5M 1 SHIV GANGA PURAM YADAVPUR ROAD UMARPUR NEEWAN PRAYAGRAJ 211011 | PRAYAGRAJ | UTTAR PRADESH | 211011 | - | Rejected-Technical Not enlisted in approprite category |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
3 Sept 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF Bamrauli
GE AF Bamrauli
PROVN OF CERTAIN EM AND AIRCONDITIONING WORK SERVICES IN OPERATION ROOMS AT CGI COMPLEX AND OTHER SANCTIONED WORKS UNDER GE AF BAMRAULI
2020_MES_366413_1
8592/E8
Open Tender
Civil Works
Item Rate
180 days
Bamrauli
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE AF Bamrauli
₹40,000
Yes
21 Sept 2020
4 Aug 2020
5 Sept 2020
4 Aug 2020
3 Sept 2020
22 Aug 2020
60 days
Amount
Supply, laying, jointing & testing of underground LT cables XLPE insulated, PVC sheathed, aluminium conductors, multistranded, armoured heavy duty 1100 Volt grade cross sectional area 25 Sqmm 4 core laid in trenches/ducts/along poles/through pipe under road etc with new aluminium lugs including taking out complete all as specified and directed. Note :- (i) Excavation, earth work, sand cushioning, protection cover and pipe shall be measured and paid for separately under respective items of this schedule.
Excavation in trenches/pits in any type of soil(soft/loose/hard/ dense soil), n.exc. 1.5M wide and n.exc. 1.5M deep and getting out complete all as specified and directed.
Returning filling in with the earth obtained from Item No 2 here-in-before including spreading, leveling and well ramming in layers n.exc. 25cm thick complete all as specified and directed.
Supply and spreading clean and dry sand (unwashed) in trenches around the cable for cushioning complete all as specified and directed.
Removal of surplus excavated material to a distance n.exc. 50 Mtr and depositing where directed at a level n.exc. 1.5 Mtr above starting point complete all as specified and directed.
Supply and laying sub class 'B' bricks (Old Size) laid flat in trenches as cable covers complete all as specified and directed.
S&F 40mm dia galvanized iron pipe, “Medium grade including fittings complete all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 60 x 60 cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised iron wire 4mm dia as earth lead wire by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in Electrical plate No. 3, MES SSR Part I- 2009 with 15 mm dia medium grade GI pipe as a protection to earthing lead and 20 mm dia medium grade GI pipe for watering purpose including excavation & earth work in any type of soil, funnel, wire mesh, RCC pit with cover, cast iron frame complete and connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed. Notes (i) The concrete pit shall be PCC (1:3:6) type C-1, 40mm thick precast cover slab of RCC with suitable Mild steel handle in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I (ii) PCC pit shall be provide at least 500 mm away from the earth pit and not on just on the eath pit and extra cost of additional length of water pipes and fittings junction etc shall be deemed to be included in the rate. (iii) Item includes the cost of 7.5 metre earth lead wire and GI pipe for protection of earth wire. Any varriation in quantity shall be adjusted.
S & F factory made, sheet metal enclosure distribution boards, double door type, protection class ( IP-42),vertical type TPNDB suitable for mounting MCCBS, MCBs confirming to IS-13032, IS-8623, BS-5484 with min 200 Amps rating copper bus bar ,TP and N 8 ways ,415 volts complete all as specified and directed. Make :ABB/Legrand/HAGER/Seimens Note: MCB/MCCBs shall be measured and paid seperatly under respective item of this schedule
Sub main wiring with 2 run of single core PVC insulated and PVC Unsheathed, multistranded copper condutor of nominal area 10 sqmm , 1100 Volts grade cable drawn into and including rigid non metalic PVC Conduit of including all fittings and one run of PVC insulated and PVC unsheathed, multistranded copper conductor of nominal area 10 sqmm 1100 volts grade cable continuous earth wire of green colour code complete all as specified and directed. Note:- (a) Two runs of 10.0 sqmm cable and one run of 10 Sqmm cable as earth lead with conduit shall be measured as one unit length for payment. (b) Quoted rate shall deem to be included cost of cutting chasses in wall for concealling conduit and making good to match with existing finish.
Factory made, sheet metal enclosure distribution boards, double door type, protection class ( IP-42), suitable for mounting MCBs confirming to IS-13032, IS-8623, BS-5484 with min 200 Amps rating copper bus bar ,SP and N 8 ways ,220 volts complete all as specified and directed. Make : ABB/Legrand/HAGER/Seimens Note: MCB/ shall be measured and paid seperatly under respective item of this schedule
MCCB, four pole, 415 Volt ,125 Amp rating, 25 KA,thermal magnatic type ultimate breaking capacity fixed in DBs catered herein before complete all as specified and directed.. Make : ABB/Legrand/HAGER/Seimens
S&F MCB, SP, 6 to 63 Amp rating, 230 volt, 10 KA, 'C' series suitable for fixing in DBs as item no 10 in this sch complete all as specified and directed. Make :ABB/Legrand/HAGER/Seimens
S&F MCB, single pole and neutral, 230 volts, 32 to 63 Amps rating, "C" series fixed in DBs catered herein before complete all as specified and directed. Make :ABB/Legrand/HAGER/Seimens
S & F Sheet metal enclosure with socket plug top and MCB single pole neutral enclsoure with 2 pin + earth plug and socket complete with one single pole MCB of 32 amps 240 volts complete all as specified and directed. Make- Legrand / Havells / schnider/HPL
M & L for Sub main wiring with 2 run of single core PVC insulated and PVC Unsheathed, multistranded copper condutor of nominal area 6 sqmm FR, 1100 Volts grade cable drawn into and including rigid non metalic PVC Conduit of including all fittings and one run of PVC insulated and PVC unsheathed, multistranded copper conductor of nominal area 4 sqmm FRLS 1100 volts grade cable continuous earth wire of green colour code complete all as specified and directed. Note:- (a) Two runs of 6 sqmm cable and one run of 4 Sqmm cable as earth lead with conduit shall be measured as one unit length for payment. (b) Quoted rate shall deem to be included cost of cutting chasses in wall for concealling conduit and making good to match with existing finish.
M & L for point wiring with PVC insulated, PVC unsheathed cable single core, nominal area 4.00 sq mm with stranded copper conductor 1100 volts grade drawn into and incl rigid PVC conduit (concealed) 19 mm internal dia with all PVC conduit fittings such as Tees, elbows, bend, reducers etc and 4.00 sq mm unsheathed copper conductor earth wire connected to earth dolly incl CI/MS boxes 1.6 mm thick with two coats of anticorrosive paint outside and aluminum paint inside sunk in wall with 3 mm thick laminated bakelite Hylam/Arkay light brand sheet cover (white) for mounting of switches, sockets and switch sockets, regulators as required complete all as specified and directed for the one 3 pin 5/15 amp switch socket out let independent . Note :- The rates of chase cutting on wall concealing conduit and steel terminal boxes are included in the unit rates.Note- colour code of wire will be strictly followed , Red for Phase , Black for neutral and green for earth wire
Supply & fix Modular switch 1 way 16A, 1 module
S&F Modular socket 6A/16A - 2/3 pin combined 2 module complete all as specified and directed.
Supply installation commissioning and testing hi wall split units indoor and outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 5 star rated, invertor type and capacity 1.5 ton including breaking necessary hole in wall any type for fixing indoor and outdoor unit and making good disturbed surfaces with cement mortar and paint to match existing surface, all as required including necessary connections complete all as specified and directed . Make : Carrier (Model No- 18 K DURAFRESH NEO-X) / Dakin(Model No-IDU:JTKJ50TV16U/ODU:RKJ50TV16U) /BLUESTAR(Model No: DATU)/LG (Model No:KS-Q18ENXA) or Equivalant Note: (i) Copper tubing ,drain pipe and 4 core multi standard copper cable of size 2.5 sqmm up to 3 meter length and floor/ wall mounted stand for AC deemed to be included in the rated quoted . Additional length shall be measured and paid separately. (ii). Warranty on Compressor should be 5 year minimum and Warranty of Machine should be 1 Year minimum.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled outdoor type,Built-In Thermal Overload Protection,Low & High Voltage cut-off Protection & designed for input variation between 150 V to 285 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA complete all as specified and directed. Make: V GUARD(Model No: VND500) / BLUEBIRD(Model No:BA514A)or equivalant .
M &L for laying of copper tubing of dia 1/2" including insulation with heavy duty rubber foam and brazing work complete all as specified and as directed.
M &L for laying of copper tubing of dia 1/4" including insulation with heavy duty rubber foam and brazing work complete all as specified and as directed
S&F PVC insulated stranded 4 core flexible copper cable of size 2.5 sqmm 1100 volt grade complete all as specified and directed.
S&F low density polyether pipe (LDPE) of pressure rating 6Kg/cm2 drain pipes of size 40 mm from indoor unit to exist point as per design including accessories clamps fastners complete all as specified and as directed.
Supply installation commissioning and testing hi wall split units indoor and outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 5 star rated, invertor type and capacity 2 ton including breaking necessary hole in wall any type for fixing indoor and outdoor unit and making good disturbed surfaces with cement mortar and paint to match existing surface, all as required including necessary connections complete all as specified and directed . Make : Carrier (Model No- 24 K DURAFRESH NEO-X) / Dakin(Model No-IDU:JTKJ60TV16U/ODU:RKJ60TV16U) /BLUESTAR(Model No: DATU)/LG (Model No:KS-Q24ENXA) or Equivalant Note: (i) Copper tubing ,drain pipe and 4 core multi standard copper cable of size 2.5 sqmm up to 3 meter length and floor/ wall mounted stand for AC deemed to be included in the rated quoted . Additional length shall be measured and paid separately. (ii). Warranty on Compressor should be 5 year minimum and Warranty of Machine should be 1 Year minimum.
M &L for laying of copper tubing of dia 5/8" including insulation with heavy duty rubber foam and brazing work complete all as specified and as directed.
M &L for laying of copper tubing of dia 3/8" including insulation with heavy duty rubber foam and brazing work complete all as specified and as directed.
Note :- Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material.
M/S vibhuti enterprises
bharat construction
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .