Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.8 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹34.9 L+₹98,296.50 (2.90%)Rejected-Finance | L2 | Rejected-Finance Other than Lowest bidder | |
| 3 | L3₹35.4 L+₹1.5 L (4.47%)Rejected-Finance 430 D DEFENCE COLONY JAJMAU KANPUR 208010 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208010 | L3 | Rejected-Finance Other than Lowest bidder | |
| 4 | L4₹36.1 L+₹2.2 L (6.43%)Rejected-Finance | L4 | Rejected-Finance Other than Lowest bidder |
Tender Value
₹48.2 L
EMD Value
₹96,500
Closing Date
28 May 2022, 6:00 pmClosed
GE(AF) B/R Chakeri Kanpur
GE(AF) B/R Chakeri Kanpur
REPAIR TO COMPOUND WALL FENCING DRAIN HARDSTANDING AND CLEANING OF SEWAGE LINE ALONG WITH CONNECTED WORKS AT 7 AFH KANPUR CANTT
2022_MES_521229_1
GE(AF)/CHK/T-04 OF 2022-23
Open Tender
Civil Works
Item Rate
270 days
7AFH Kanpur Cantt
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE(AF) B/R Chakeri Kanpur
₹96,500
13 Aug 2022
30 Apr 2022
4 Jun 2022
30 Apr 2022
28 May 2022
14 May 2022
Amount
Demolition of cement concrete of any description and in any position not otherwise specifically provided for including chaina mozaic, WC etc complete all as specified and directed.
M&L for PCC (1:7:12) type E-2 using 40 mm graded stone aggregate as in sunken floor compete all as specified and directed.
M&L for 32 mm dia galvanised tubing medium grade as in spout pipe each 50 cm long, cutting to shape as required, cutting through wall of any thickness, fixing in PCC (1:2:4) tpe B-1 making god the damaged portion by rendering in CM (1:4) and finished the surface to match the existing surface complete all as specified and directed.
M & L for 100 mm bore cast iron 'P' or 'S' trap fixed complete with M seal joint to cast iron 100 mm bore pipe duly fixed in position in repairs including closing the wall opening in CM (1:3) complete all as specified and directed.
M&L for providing and applying two component cemenltious elastomeric water proofing coating of approved make in two steps in two coats @1.4 kg/sqm to build 1.00 mm thickness as per manufacturers specification. The first coat shall be applied @ 0.7 kg/sqm and while 1st coat still green the second coat shall be applied with a suitable and stiff brush @ 0.7 kg/sqm. The treatment shall be carried out both horizontal and vertical surface as per site requirement. Substantially curing to be done by ponding for 48 hours complete all as specified and directed.
Demolition of RCC of any discription in any position not otherwise described including cutting reinforcement as required and removing the debries out of MD land complete all as specified and directed.
M&L for precast RCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in man-hole cover slabs, set in CM (1:4) complete all as specified and directed. (Note :- Reinforcement shall be measured and paid separately under relevant item of Sch 'A' item here-in-after).
M&L for TMT bars 10 mm dia and over cut to length bent to shape required, including cranking, bending hooking etc & binding with mild steel binding steel wire (annealed) not less than 0.9mm dia conforming to Fe-410-S or Fe – 410-O complete all as specified and directed.
M&L for TMT bars 6 to 8mm dia cut to length bent to shape required, including cranking, bending hooking etc & binding with mild steel binding steel wire (annealed) not less than 0.9mm dia conforming to Fe-410-S or Fe – 410-O complete all as specified and directed.
Exacavation in trenches not exceeding 1.5 m wide & not exceeding 1.5 m in depth and getting out in soft / loose soil complete all as specified and directed.
Ditto all as per item No. 10 above but exceeding 1.5 mtr and not exceeding 3.0 mtr in depth complete all as specified and directed.
Exacavation over area not exceeding 1.5m deep and getting out in soft/loose soil complete all as specified and directed.
Exacavation over area exceeding 1.5 m and not exceeding 3m deep and getting out in soft/loose soil.
Returning filling in including spreading, levelling, watering and well ramming in layers not exceedingeeding 25cm in layers complete all as specified and directed.
S & F in repair 150 mm bore dia RCC pipe class NP-2 laid and jointed in CM (1:30 with collars and tested complete all as specified and directed
S & F in repairs 200 mm bore dia RCC pipe class NP-2 laid and jointed in CM (1;3) with collars and tested complete all as specified and directed.
S & F in repair 300 mm bore dia RCC pipe class NP-2 laid and jointed in CM (1:3) with collars and tested complete all as specified and directed
M&L for PCC (1:3:6) type C2 using 40 mm graded stone aggregate as in concrete bed to drain pipes of 150mm bore dia including packing under and haunching against the sides of pipe after they are laid complete all as specified and directed
M&L for PCC (1:3:6) type C2 using 40 mm graded stone aggregate as in concrete bed to drain pipes of 200 mm bore dia including packing under and haunching against the sides of pipe after they are laid complete.
M&L for PCC (1:3:6) type C2 using 40 mm graded stone aggregate as in concrete bed to drain pipes of 300mm bore dia including packing under and haunching against the sides of pipe after they are laid complete.
Taking down cement plaster including raking out joints hacking for key scrubbing down with water etc complete all as specified and directed.
M&L for rendering 15 mm thick on fair faces of concrete surfaces or brick work in CM (1:4) mixed with WPC @ 3% by weight of cement finished even and fair and applying three coat of white wash complete all as specified and directed. (Note : WPC shall be measured and paid separately under relevant item of Sch 'A' item here-in-after).
Supply only water proofing compound ISI marked complete all as specified and directed.
S & F (SWR) gulley trap of size 125/110mm setting and jointing with solvent cement.
S&F Greating doom of size 125mm dia with waste hole of PTMT. (Maxium weight 40 gms) complete all as specified and directed.
Demolition of brick masonary built in cement mortar including all quoins, arches, pillars etc and clearing off the premises complete all as specified and directed.
M&L for Brick work with fly ash bricks using old size bricks on plane not exceeding 6 mtr mean redious built in CM (1:6) as in wall etc complete all as specified and directed.
M&L for Brick work with sub class 'B' bricks using old size bricks obtained from dismantling on plane not exceeding 6 mtr mean redious built in cement mortar 1:6 as in wall etc.
M&L for rendering 15mm thick on fair faces of concrete surfaces or brick work in CM (1:4) with neru finish complete all as specified and directed
Demolition of PCC not exceeding 15 cm thickness in floors, roofs or pavings and throwing debris at low lying area not exceeding 1 km complete all as specified and directed
Demolition PCC (un-reinforced) of any description and in any Position not otherwise specifically provided for, complete all as specified and as directed.
M&L for PCC (1:3:6) type C-2 using 40mm Graded Stone Aggregate as in Surface Channels and Drains, etc, including use and waste of necessary Form Work, complete all as specified and directed.
M&L for PCC (1:2:4) type B-1 using 20 mm graded aggregate as in coping/benching of manhone etc including necessary form work complete all as specified and directed.
M&L for PCC (1:4:8) type D2 using 40 mm graded stone aggregates as in foundation filling and mass concrete complete all as specified and directed.
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement including forms, moulds, mitred/stopped ends etc complete all as specified and directed.
M&L for 75mm thick PCC (1:3:6) type C-2 using 40 mm graded stone aggregate as in plinth protection finish even and smooth without using extra cement with construction joints complete all as specified and directed
S&F in repairs 110mm dia PVC (SWR) grade single socketed pipes in any length complete with rubber ring joints laid in trenches or in floors, on walls.
S&F in repairs 75mm dia PVC (SWR) grade single socketed pipes in any length complete with rubber ring joints laid in trenches or in floors, walls etc complete all as specified and directed.
S&F in repairs 110 mm dia PVC (SWR) bends of any radius complete all as specified and directed.
S&F in repairs 75 mm dia PVC (SWR) bends of any radius complete all as specified and directed.
S&F in repair 110 mm dia pipe for PVC (SWR) junction (single ‘T’) with / without access door complete all as specified and directed.
S & F in repair 75 mm dia pipe for PVC (SWR) junction (single ‘T’) with / without access door complete all as specified and directed..
S & F in repair for PVC (SWR) vent cowl suitable for 75mm dia PVC pipe complete all as specified and directed.
Opening & cleaning of blockage of WC, nahani trap/ gully trap of bathroom, kitchen and messes etc any pattern by rodding or manually upto 1st manhole without damaging any sanitary fitting etc including taking down and refixing of manhole covers in original position complete all as specified and directed
Cleaning of chocked/blocked sewage lines of any bore by collecting loose sedimented sand, frill, ash, sludge water, rags, fibers or vegetation in nearest manholes for disposal including taking down cover slab of any type, thickness and size carefully and refixing in same position after necessary cleaning and removing the cleaned sludge out side the MOD land in sealed containers complete all as specified and directed from the following depth of sewage lines:
Upto 1.50 m depth.
Exceeding 1.50 m and not exceeding 3.00 m depth.
Exceeding 3.00 m and not exceeding 5.50 m depth.
Cleaning of manholes of depth not exceeding 1.5 M deep manually by taking off sludge waste soil and silted soil from the existing manhole of any size including taking down cover slab of any type, thickness and size carefully and refixing in same position after necessary cleaning and removing the cleaned sludge out side the MOD land in sealed containers complete all as specified and directed.
Ditto all as per item No 46 above but exceeding. 1.5 mtr and not exceeding. 3 mtr deep.
Ditto all as per item No 46 above but exceeding. 3 mtr deep.
Cleaning of septic tank/ main chambers mechanically by opening the covers, removing liquid/ sludge mixed liquid under any position including foul conditions and cleaning the inlets and outlets etc with water, placing the covers back in position and disposing off the same out side MD land complete all as specified and directed. (Note:- The liquid (sludge mixed) to be disposed off in sealed tins or sludge removal tankers and the same is deemed to be included in the quoted unit rate).
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching and forming branch channel 91/1 round or 3/4 section ) in PCC (1:2:4) type B-1 using 20 mm graded stone aggregate smooth finished and reforming benching as required in 150mm dia rendering, cutting out branch channel and making good the disturbed surfaces complete all as specified and directed.
M & L for cleaning of roofs/Chajja by getting out growing vegetations/grass & brooming down with removing it out of MD land premises including repairing to damaged surface of roof by using CM (1:3) mixed with 3% WPC by weight of cement & sealed with 85/25 hot blown grade bitumen complete in patch not exceedingeeding 5.0 Sqm each complete all as specified and directed.
M & L for repairing of damaged portion of mouth at tarrace/roof surface of rain water pipe by cleaning and repairing to mouth of RWP by using CM(1:3) with mix with 3% by weight of cement WPC & sealed with 85/25 hot blown grade bitumen complete to make joint of rain water pipe and roof surface fully leak proof complete all as specified and directed.
Dismantling structural steel work including doors, gates, cattle trap but exceeding framed truss etc complete all as specified and directed.
M & L for rolled sections as in framing for cladding, glazing and the like fixed with angle cleats and connecting plates, etc conforming to Fe 290 Gde E 165 complete all as specified and directed.
S & F steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with reveted welded, bolted attatchments conforming to Fe 290 Gde E 165 complete all as specified and directed.
M & L for 18-20 mm thick granite (of any type) work (table rubbed and polished) in steps jambs, pillers, window -cills cooking platforms and like over and including 15 mm thick screed bed in CM (1:4) and jointing & pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
M&L for preparation of new plastered surfaces of wall and applying two coat of cement based paint over one coat of cement primer complete all as specified and directed.
S&F in repair galvanised 2 strand steel bar-beds wire 2.25 mm dia barbed with 2 mm dia barbs at 75 mm spacing and straining and fixed to any type of standered rails straining bolts including securing or tying and binding at crossing with and galvanised mild steel wire staple etc complete all as specified and directed.
Ditto all as per item no 58 above but restraining and re securing including making good staple etc complete all as specified and directed.
M&L for 40 mm thick providing precast RCC Jali 40 mm thick made out of PCC (1:2:4) B-0 using 12.50 mm graded stone aggregates including suitable reinforcement complete all as specified and directed.
M&L for 60 mm thick machine pressed precast concrete interlocking paver block having laquer finish of any shape and size confirming to IS 15658-2006 grade M-35 jointed and pointed with grey cement and pigment including dismantling old interlicking paver block complete all as specified and directed.
M&L for hard core of gauge not exceeding 63 mm of broken granite stone deposited spread and levelled in layers not exceeding in layers 15 cm thick watered and rammed to a true surface complete all as specified and directed.
M&L for sand filling under floors or in foundation including watering well ramming and cosolidation complete all as specified and directed.
M&L for glazed chequered cement concrete tiles of size 200 mm X 200 mm X 22 mm / 300 mmX300mmx22 mm laid in floors etc over and including 15 mm thick screed bed in CM (1:4) set jointed with pigments to match the shade of tiles complete all as specified and directed.
Dismantling floor, hearth or wall Ttling including Cement Mortar bedding (but not backing), and removing rubbish off the premises, complete all as specified and directed.
M&L for coloured non skid ceremic tiles of size 300 mm X 300 mm X 10 mm thick heavy duty laid in floors etc set and jointed in neat cement slurry @ 3 kg /sqm and pointed in white cement mixed with pigment to match the shade of tiles laid over and including 15 mm thick screed bed in CM (1:6) complete all as specified and directed.
M&L for 7 to 8 mm thick glazed coloured ceremic joint free tiles on vertical surface of size 600 mm X 300 mm /450 mm x 300 mm or as required, set over and cncluding 10 mm thick backing coat in CM (1:4) and jointed in neat cement slurry @ 3 Kg/Sqm and pointed in white or coloured cement to match the shade of tiles , complete all as specified and directed
M&L 7 to 8 mm thick for non skid ceramic digital coloured tiles square or rectangular area of each tile exceeding 0.11sqm but not exceeding 0.18 sqm mm as in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including15 mm thick screed bed in CM (1:6) dismantling including of old tiles and removing from site, complete all as specified and directed
S&F in repairs 15 mm bore tubes medium grade galvanized with all fitting and fixed to walls and ceilings or laid in floors of any length including complete all as specified and as directed
S&F in repair 20 mm bore tubes medium grade galvanized with all fitting and fixed complete to walls and ceilings or laid in floors of any length complete all as specified and directed
M&L for vitreous china squatting pan Orissa Pattern of size 580mm x 440mm white with integral foot rest including connection to trap, and to flushing pipe, anti-syphonage pipe, etc. including making good disturbed surfaces complete all as specified and directed.
S & F in repairs vitreous China Wash down Water Closet Pan (Pedestal Pattern) White including fixing Bolts (excluding Flushing Cistern and Flushing Pipe) with Plastic Water Closet Seat, Black, Closed Pattern with Recessed Bottom and Cover including Mild Steel Chromium Plated Aluminium Hanging Device and to disturbed Surfaces with Cement Mortar (1:3) complete all as specified and directed.
S&F 100 mm bore dia cast iron bends (any radius) with duck's foot rest & oval access doors with cement joint, fixed on walls complete all as specified and directed
S&F 75 mm bore dia cast iron bends (any radius) with duck's foot rest & oval access doors, with cement joint, fixed on walls complete all as specified and directed
S & F PVC (SWR) floor trap of 75 mm outlet plain with grating including jointing with solvent cement complete all as specified and directed
S & F in repair 100 mm bore dia cast iron pipes and vent pipes(sand cast), any length with or without ears with cement joint, fixed on walls complete all as specified and directed
S&F in repair 75 mm bore dia cast iron pipes and vent pipes (sand cast), any length with or without ears with cement joint, fixed on walls complete all as specified and directed
Dismantling of RCC posts or struts any description, any section including taking out embedded portion in concrete, brick masonary etc and making good disturbed ground complete all as specified and directed.
S&F mild steel work as in gate post and struts in fencing including cutting top to shape as directed, drilling holes, notching of wire etc complete all as specified and directed
Supply only chain link MS galvanised fencing having mash size 75 mm x75 mm x3.15 mm of any type complete all as specified and directed
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified and directed.
Excavation in post holes not exceeding 0.50 Cum, getting out, returning filling, in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25 cm in soft/loose soil complete all as specified and directed.
M&L for 22 to 25 mm thick machine cut pre-polished kota stone slab flooring over and including 15 mm thick screed bed in CM (1:6) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M & L for 22 to 25 mm thick machine cut pre-polished kota stone slab as in riser of steps, skirting, dado and pillar laid over and including 10 mm thick cement plaster in CM (1:4) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete (Note : The rate includes the cost of cement plaster )
M & L for rendering 15mm thick on brick/stone or concrete surfaces in cement Mortar (1:4) finished fair and even without using extra cement complete all as specified and directed.
M & L for preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
M/s DKS Engineering Works
JOG CONSTRUCTION
Khalil Ahmed and Sons
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .