| 1 | L1₹32.0 LAccepted-AOC RM 01 RIDHISIDHI I SRI GANGANAGAR 335001 RAJ | SRI GANGANAGAR | SRI GANGANAGAR | RAJASTHAN | 335001 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹33.4 L+₹1.4 L (4.32%)Rejected-Finance C O GENERAL DAIRY VILLAGE BARAGAON SRI GANGANAGAR 335 001 | GANGANAGAR | RAJASTHAN | 335001 | L2 | Rejected-Finance Highest bid quoted other than L1 |
Tender Value
₹38.2 L
EMD Value
₹76,380
Closing Date
7 Sept 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Sri Ganganagar
Garrison Engineer Sri Ganganagar, Military Engineer services , Sri Ganganagar Cantt Rajasthan-335001
PROVN OF CERTAIN SENCTION MW AND RW AND LBW WORK IN THE AREA OF AGE B/R-II UNDER GE SGNR AT MILITARY STATION SRI GANGANAGAR
2020_MES_367977_1
GE SGNR/ TOK- 28 OF 2020-21
Open Tender
Civil Works
Item Rate
180 days
GE Sri Ganganagar
D Class a (i) and for un-enlisted, refer NIT para 8
6 documents required · 6 mandatory
₹500
GE SGNR
₹76,380
Yes
11 Nov 2020
10 Aug 2020
9 Sept 2020
10 Aug 2020
7 Sept 2020
17 Aug 2020
60 days
Amount
Surface excavation n.exc 30 cm deep and averaging 15cm deep, surface preparation as per required gradient and camber including well ramming and getting out in soft/loose soil complete all as specified and directed by Engineer - in - Charge
Excavation over areas n.exc. 1.5 m wide & n. exc. 1.5m in depth for foundation etc. n. exc 10 sqm on plan and n. exc. 1.5 m in depth in hard/loose soil and getting out complete all as specified and directed by Engineer - in - Charge
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed by Engineer - in - Charge
Returning filling in, including spreading levelling, watering and well ramming in layers not exc. 25 cms thick in soft/ loose soil complete all as specified and directed by Engineer - in - Charge.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exc 25 cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface in soft/loose soil complete all as specified and directed by Engineer-in-Charge.
Surface dressing n. exc. 15 cm deep in soft/loose soil complete all as specified and directed by Engineer-in-Charge .
Spreading and levelling in layers n exc. 25 cm thick for well ramming including watering as required complete all as specified and directed by Engineer - in - Charge.
M & L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed by Engineer - in - Charge.
Removing excavated material n. exc. 50 m & depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed by Engineer - in - Charge.
M&L for hard core of gauge n. exc 63 mm, deposited spread and levelled in layers n. exc 15 cm thick, watered and rammed to a true surface using broken stone or boulders complete all as specified and directed by Engineer - in - Charge.
M&L for treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed by Engineer - in - Charge.
M&L for treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all as specified and directed by Engineer - in - Charge.
M&L for treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and directed by Engineer - in - Charge.
M&L for treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed by Engineer - in - Charge.
M&L for treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and directed by Engineer - in - Charge.
M&L for PCC (1:4:8) type D-2, (40 mm graded stone aggregate) as in foundation complete all as specified and directed by Engineer - in - Charge
M&L for PCC 1:3:6 Type C-2 (40mm graded stone aggregate) for foundations filling of post hole and struts complete all as specified and directed by Engineer - in - Charge.
M&L cement concrete 1:5:10, Type E-2 (40 mm graded stone aggregate) as in filling and mass concrete complete all as specified and directed by Engineer-in-charge.
M&L PCC 1:3:6 type C-0 (12.5 mm graded aggregate) for filling of pressed steel frame and hold fast etc. complete all as specified and directed by Engr-in-charge.
M&L for PCC 1:11/2:3 , Type B-0 (12.5 mm graded aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed by Engineer - in - Charge.
M & L for PCC 1:2:4 Type B –1 (20mm graded stone aggregate) for kerb stone and similar works with plain fair faces, including chamfers, weatherings, throat- ing etc. and setting in CM 1:4 with joints to match complete all as specified and directed by Engineer - in - Charge.
M&L for reinfocement cement concrete 1: 2:4 Type B-1 (Nominal mix) (20mm graded stone aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed by Engineer - in - Charge
M&L for pre-cast RCC jallies 25 mm thick(measured soild) 1:2:4 , Type B-0 (12.50 mm graded stone aggregate) and set in cement mortar 1:4 complete all as specified and directed by Engineer - in - Charge.
M & L for pre-cast cement concrete 1:2:4 Type B –1 (20mm graded stone aggregate) as in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces set in cement mortar 1:4 complete all as specified and directed by Engineer - in - Charge.
M&L for reinfocement cement concrete 1: 2:4 Type B-1 (Nominal mix) (20mm graded stone aggregate) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed by Engineer - in - Charge
M&L for reinfoced cement concrete 1: 2:4 Type B-1 (12.5mm graded stone aggregate) (Nominal Mix) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed by Engineer - in - Charge
M&L for reinfocement cement concrete 1: 2:4 Type B-1 (Design mix M-25 ) (20mm graded stone aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams, bases for columns, etc. basement slabs, under-reamed piles and mass concrete complete all as specified and directed by Engineer - in - Charge
M&L for reinfocement cement concrete 1: 2:4 Type B-1 (Design mix M-25 ) (20mm graded stone aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed by Engineer - in - Charge
M&L for reinfocement cement concrete 1: 2:4 Type B-1 (Design mix M-25 ) (20mm graded stone aggregate) as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed by Engineer - in - Charge
M&L for reinfocement cement concrete 1: 2:4 Type B-1 (Design mix M-25 ) (20mm graded stone aggregate) as in Columns, pillars, piers, posts and struts complete all as specified and directed by Engineer - in - Charge
Supply only integral water proofing compound ISI marked complete all as specified and directed by Engineer - in - Charge
M & L brick work with sub class 'B' bricks straight or curved on plan exceeding 6 mtr mean radius built in CM 1:6 complete all as specified and directed by Engineer - in - Charge.
M & L brick work with sub class 'B' bricks straight or curved on plan exceeding 6 mtr mean radius built in CM 1:4 complete all as specified and directed by Engineer - in - Charge.
M & L brick work with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed by Engineer - in - Charge.
M& L for brick work with fly ash bricks, straight or curved on plan to any radius in half brick thick walls, built in CM 1:4 complete all as specified and directed by Engineer - in - Charge.
Supply and laying fire bricks, size 230 x113 x 75 m complete all as specified and directed by Engineer - in - Charge.
M&L 20mm thick Granite (of any type) (table rubbed and polished) work in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed by Engr-in-charge.
M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished surfaces of concrete complete all as specified and directed by Engineer - in - Charge
M&L for form work to sides & soffits of suspended slab such as roof slabs, floor slabs, landings and similar work; n. exc 200mm thick (Horizontal or sloping) for rough finished surfaces of concrete complete all as specified and directed by Engineer - in - Charge
M&L for formwork to to sides of pillars, posts, struts, piers, columns and stanchions including for edges for rough finished surfaces of concrete complete all as specified and directed by Engineer - in - Charge
Taking down chowkats or frames (without taking off shutters from the frame) n. exc.1.5 sqm each complete all as specified and directed by Engineer - in - Charge.
M&L for pressed steel frame for doors of size 125 x 60 mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc complete all as specified and directed by Engineer - in - Charge.
S & F 2nd class hard wood plain, solid, straight chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed by Engineer - in - Charge.
S & F Second class hard wood factory made wire glazed and skeleton window shutters, 25mm thick, open rebated and prepared to receive glass, gauze, etc divided into squares with plain, chamfered or rounded mitred and rebated sash bars any number & fitted with cut and mitred beads for securing gauze/wire cloth, etc sizes of members of shutters as specified in SSR Part-I, section 8 clause 8.24 (a) complete all as specified and directed by Engineer - in - Charge.
S & F 35mm thick,Second class hard wood factory made Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed by Engineer - in - Charge.
S & F Fiber Glass Reinforced plastic (FRP) Door Frames of required colour of three legged of cross section 90mmx45mm having single rebate of 32mmx45mm having single rebate of 32mmx15mm to receive shutter of 30 mm thickness. The laminate door frame molded with fire retardant grade unsaturate polysterresinn and chopped mat.Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiberglass from all sides, MS stay shall be provided at the bottom to steady the frame complete all as specified and directed by Engineer - in - Charge
S & F 30mm thick glass fiber reinforced plastic (FRP) paneled door shutter of required colour and approved brand and manufacture made with fire retardent grade unsaturated polyster resin moulded to 3mm thick FRP laminated for forming hollow rails and style with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings cast monolithically with 5mm thick FRP laminate for panels for conforming to IS:14856-2000 complete all as specified and directed by Engineer - in - Charge.
S & F mild steel clamps made out of 40x6 mm by 5 mm flat iron in two halves for tapping through 40 to 100 mm bore GI/DI water pipe line including drilling and welding of 15/20 mm GI socket and necessary rubber insertion, nut, bolts & wahers complete all as specified and directed by Engineer-in-charge.
S & F alluminium anodised barrel tower bolts 100mm long extruded section complete all as specified and directed by Engineer - in - Charge.
S & F alluminium anodised barrel tower bolts 125mm long extruded section complete all as specified and directed by Engineer - in - Charge.
S & F alluminium anodised barrel tower bolts 150mm long extruded section complete all as specified and directed by Engineer - in - Charge.
S & F 150mm long mild steel barrel tower bolts,stove stove enamelled black, with bright bolt and fixed complete all as specified and directed by Engineer - in - Charge.
S&F 300mm mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed. complete all as specified and directed by Engineer - in - Charge.
S & F butt hinges, medium weight, cold rolled mild steel, and fixed of size 100mm fixing properly with screws etc complete all as specified and directed by Engineer - in - Charge.
S & F aluminium butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type C-21 of size 75 mm fixing properly with screws etc complete all as specified and directed by Engineer - in - Charge..
S&F 150mm size mild steel pressed handle, oval type, stove enamelled black complete all as specified & directed by Engineer-in-Charge.
S & F 125 mm long extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed by Engineer - in - Charge
S & F 150 mm long extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed by Engineer - in - Charge
S & F 100 mm long extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed by Engineer - in - Charge
S & F stainless steel tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed by Engineer-in-Charge.
S&F floor door stopper of aluminum alloy body and (over all length of cover plate 150 mm) tongue anodised with hard drawn steel spring fixed in door complete all as specified and directed by Engineer-in-chrage.
S&F stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed by Engineer - in - Charge.
M&L for TMT bars 8 to 10 mm dia and over cut to length bent to shape required including cranking bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90 mm dia using TMT bars complete all as specified and directed by Engineer - in - Charge.
M & L for mild steel TMT bars 5mm dia and over upto and including 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia as in stirrups, spacers and binders complete all as specified and directed by Engineer - in - Charge.
S&F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified and directed by Engineer - in - Charge.
M&L for Steel work in tubular trusses post, purlins including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and directed by Engineer - in - Charge
M&L for Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete with Powder Coating on aluminium minimum thickness of powder coating 50 micron all as specification the top and bottom horizontal members and vertical members adjacent walls and cills where required and fixing with the help of rawl plug and screw or with fixing clip or with expansion hold plate fasteners. Aluminium section shall be smooth, rust free, straight mitred and jointed mechanically where ever required complete all as specified and directed by Engineer - in - Charge.
S&F powder coated aluminium windows and ventilator shutters, side hung type without sash bars, aluminium saction weighing 0.55 kg/M including necessary jointing cleats, glazing clips, rubber packing, powder coated aluminium snap beading, screws, powder coated aluminium fitting such as aluminium peg stay 150mm long (1No), powder coated aluminium hinges type B-21 100 mm long (2No), suitable powder coated aluminium handle -(1No), and powder coated aluminium self closing tower bolt 75mm long (1No) complete all as specified and directed by Engineer - in - Charge.
S&F Anodised aluminium snap grid frame work for false ceiling Size of grid 605 x 605mm complete all as specified and directed by Engineer - in - Charge
S&F Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long Size of grid 605 x 605mm complete all as specified and directed by Engineer - in - Charge
M&L for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-charge.
M&L for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-charge.
M&L for wire brushing and cleaning top surface of roof or cement concrete and applying evenly a tack coat of industrial bitumen 85/25@ 1.2 kg/ sqm complete all as specified and directed by Engineer - in - Charge.
M&L for Providing and fixing Gypsum Board 12mm thick size (600x600) in ceiling fixed with screw as per manufacturers instructions complete all as specified and directed by Engineer - in - Charge
M & L for 18- 20 mm thick machine cut kota stone slab flooring laid over and including 15 mm thick screed bed in CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and directed by Engineer - in - Charge.
M & L for 18-20 mm thick machine cut kota stone slab as in vertical surfces such as skirting, dados etc, laid over and including 10 mm thick backing coat in CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and directed by Engineer - in - Charge.
M & L for 75 mm thick cement concrete 1:3:6 type C –1 (20mm graded stone aggregate) as in plinth protection or similar works finished even and smooth with using extra cement etc complete all as specified and directed by Engineer - in - Charge.
M&L for 50mm thick cement concrete 1:2:4, Type B-1 (20mm graded aggregate) as in sub base, foundation filling and mass concrete complete all as specified and directed by Engineer - in - Charge
M&L for 75mm thick cement concrete (1:4:8) type D-2, (40 mm graded stone aggregate) as in sub base, foundation filling and mass concrete complete all as specified and directed by Engineer - in - Charge
M&L for 100mm thick cement concrete (1:4:8) type D-2, (40 mm graded stone aggregate) as in sub base, foundation filling and mass concrete complete all as specified and directed by Engineer - in - Charge
M&L for 100 mm thick cement concrete 1:2:4, Type B-1 (20mm graded aggregate) as in floor finished even and fair complete all as specified and directed by Engineer - in - Charge.
M&L for 25 mm thick cement concrete 1:2:4, Type B-1 (20mm graded aggregate) as in floor finished even and fair complete all as specified and directed by Engineer - in - Charge.
M&L for 75 mm thick cement concrete 1:2:4, Type B-1 (20mm graded aggregate) as in floor finished even and fair complete all as specified and directed by Engineer - in - Charge.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. and brushing neat cement slurry with 3.0kg of cement per sq. metre complete all as specified and directed by Engineer - in - Charge.
M&L for precast coloured rubber moulded concrete machine pressed concrete interlocking paver blocks any shape and size conforming to IS 15658-2006 of 60 mm thickness, M 35 grade wirh grey cement and pigment complete all as specified and directed by Engineer-in-Charge.
M&L for non skid coloured ceramic tiles 7 to 8 mm thick (square / rectangular) area of each tile exc. 0.11 sqm but not exc 0.18 sqm in floor etc, laid over and including 15 mm thick screed bed in CM 1:6 and set and jointed in cement slurry and pointed in white cement mixed with pigment to match the shade of tiles complete all as specified and directed by Engineer - in - Charge.
M&L for non skid coloured ceramic tiles 7 to 8 mm thick (square / rectangular) area of each tile exc. 0.06 sqm but not exc 0.11 sqm in floor etc, laid over and including 15 mm thick screed bed in CM 1:6 and set and jointed in cement slurry and pointed in white cement mixed with pigment to match the shade of tiles complete all as specified and directed by Engineer - in - Charge.
M&L for glazed ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each exc. 0.18 sqm but not exc 0.36 sqm on vertical surfaces laid over and including rendering 10 mm thick in CM 1:4 and set and jointed in cement slurry and pointed in white cement mixed with pigment to match the shade of tiles complete all as specified and directed by Engineer - in - Charge.
M&L for virified ceramic tiles 10mm thick (square / rectangular) area of each tile exc. 0.18 sqm but n. exc 0.36 Sqm in floors etc. laid over and including 15 mm thick screed bed in CM 1:4, set and jointed in cement slurry mixed with pigment to match the shade of tiles complete all as specified and directed by Engineer-in-Charge
M&L for glazed ceramic coloured tiles interior grade, of size 450x350x7mm thick as on vertical surfaces like dados or skirting laid over and including 10mm thick rendering in CM 1:4 and jointed in neat cement slurry and pointed in white cement mixed with pigment to match the shade of tiles complete all as specified and directed by Engineer - in - Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed by Engineer-in-charge.
Taking down cement plaster on brick or concreate wall surfaces including racking out joints, hacking for key, scrubbing down with water etc. complete complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 10 mm thick in CM 1:4 to roof surfaces with water proofing compound finished even & smooth without using extra cement complete all as . Note:- water proofing compound shall be measured seperately
M&L for rendering 15 mm thick in CM 1:4 on brick work or concrete work surfaces including finished even & smooth without using extra cement complete all as specified and directed by Engineer - in - Charge.
M&L 15 mm thick rendering in CM 1:6 on brick / concrete wall surfaces including finished even & smooth without using extra cement complete all as specified and directed by Engineer - in - Charge.
M&L 15 mm thick rendering in CM 1:3 using WPC @3% by weight of cement on brick / concrete wall surfaces including finished even & smooth without using extra cement complete all as specified and directed by Engineer - in - Charge. Note:- WPC shall be measured measured seperately
M&L 5 mm thick rendering in CM 1:3 on ceiling surfces including finished even & smooth without using extra cement complete all as specified and directed by Engineer - in - Charge.
M&L for preparation of new plastered surfaces of walls and applying two coats of cement based paint over a coat of white wash complete all as specified and directed by Engineer - in - Charge.
M&L for preparation of new plaster surfaces of walls and applying three coat of white wash complete all as specified and directed by Engineer-in-charge.
M&L for preparation of new plaster surfaces of ceiling and applying three coat of white wash complete all as specified and directed by Engineer-in-charge.
M&L for preparation of newly plastered surfaces of walls and applying two coats of oil emulsion distemper, over a coat of chalk whiting complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new wood and wood based surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint (ordinary tint) over a coat of Pink primer complete all as specified and directed by Engineer - in - Charge.
M&L for preparation of new plastered surfaces of wall and applying two coats of Plastic emulsion complete all as specified and directed by Engineer - in - Charge.
M&L for preparation of new steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint (ordinary tint) over a coat of red oxide, zinc chrome primer complete all as specified and directed by Engineer - in - Charge
S & F Galvanised steel water tubing 20 mm bore medium grade with all fittings concealed including cutting chases to brick wall/ceiling or laying in floors and making good disturbed surfaces complete all as specified and directed by Engineer-in-Charge.
Taking down 15 mm bore Galvanised steel water tubing with all fittings complete all as specified and directed by Engineer-in-Charge.
S & F Galvanised steel water tubing 15 mm bore medium grade with all fittings concealed including cutting chases to brick wall/ceiling or laying in floors and making good disturbed surfaces complete all as specified and directed by Engineer-in-Charge.
S & F Galvanised steel water tubing 15 mm bore medium grade with all fittings, laid in trenches complete all as specified and directed by Engineer-in-Charge. Note:- Excavation and earth work shall be measured and paid seperately
S&F rotational moulded white colour polyethylene water storage tank 500 litre capacity (Cylindrical vertical with closed top) hoisted and fixed in position with necessary fittings complete all as specified and directed by Engineer - in - Charge. (Note : PVC tanks shall be ISI marked, having three layres and white colour)
S & F in repairs 15mm bib tap cast copper alloy,fancy type, chromium plated with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferule complete all as specified and directed by Engineer-in-Charge. Make: Prayag cat part no-8306 Parryware cat part no- T3504A1, Cera cat part no- HTF3001151 or equivalent cat part as approved by GE
S&F in repairs 15mm bore Pillar taps cast copper alloy fancy type chromium plated screwed down high pressure with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and directed by Engineer-in-Charge.
S&F 15mm bore stop cock / valve cast copper alloy, fancy type chromium plated screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe complete all as specified and directed by Engineer-in-Charge.
S & F in repairs 15 mm bore gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directrd by Engineer in charge.
S&F 20mm bore Ball brass valves high pressure with polythene float and fly nut complete screwed for iron pipe or brass ferrule complete all as specified and directed by Engineer - in - Charge.Note:- Minimum weight 455gms
S&F Shelf of PTMT fixed with and including Chromium plated brass screws and wooden/ plastic cleats (Minimum weight 300gms) complete all as specified and directed by Engineer-in-Charge.
S&F 100mm bore sand cast, cast iron soil, waste and vent pipes in any length with or without ears with cement joints laid in trenches or fixed to wall complete all as specified and directed by Engineer - in - Charge
S&F 75mm bore sand cast, cast iron soil, waste and vent pipes in any length with or without ears with cement joints laid in trenches or fixed to wall complete all as specified and directed by Engineer - in - Charge
S&F 100mm bore cast iron Bends (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified and directed by Engineer-in-Charge.
S&F 75mm bore cast iron Bends (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified and directed by Engineer-in-Charge.
S&F PVC (SWR) floor trap 75 mm size , plain with grating including jointing with solvent cement complete all as specified and directed by Engineer-in-Charge.
M & L for PCC 1:3:6 type C –2 bed to drain pipes 150 mm including packing under, haunching against the sides of pipes after they are laid and tested complete all as specified and directed by Engineer - in - Charge.
M&L for reinfocement concrete pipes, class NP2, laid and jointed complete with collars complete all as specified and directed by Engineer - in - Charge
S&F grating doom 100 mm dia of PTMT complete all as specified and directed by Engineer-in-Charge. Note:- Minimum weight 25gms
S&F in repairs stainless steel plate rack 600x750x250 mm thickness of sheet 1 mm thick complete all as specified and directed by Engineer - in - Charge.
S&F in repairs PVC connections 15mm size with PTMT nut of length 450mm complete all as specified and directed by Engineer-in-Charge. Make:- Prayag cat part No- BS-115(long) or equivalent cat part as approved by GE
S&F in repairs vitreous china urinal, bowl type (back or corner wall type), complete including providing and fixing plugs bedding urinal against wall in cement mortar 1:2, securing urinals to plug with and including 60mm long brass screws and brackets, 32mm bore LDPE flush pipe of pressure rating 6 Kg/ Cm2 and grating and union for discharge pipe, waste coupling of PTMT minimum weight 45 gm, including urinal spreader of PTMT any colour for fixing with 15 mm dia pipe complete all as specified and directed by Engineer - in - Charge.
S&F in repairs, vitreous china wash down water closet pan (Pedstal pattern) white excluding flushing cistern & flush pipe but including seat cover complete all as specified and directed by Engineer - in - Charge.
S&F water closet vitreous china squatting pan "Orrisa pattern" size 580mmx440mm white with integral foot rests and CI 'P' trap and proper connecting to flushing cistern complete all as specified and directed by Engineer-in-charge.
S&F in repair water closet vitreous china squatting pan "Orrisa pattern" size 580mmx440mm white with integral foot rests and CI 'P' trap and proper connecting to flushing cistern complete all as specified and directed by Engineer-in-charge.
S&F vitreous china wash hand basin white, flat back size 550x400mm including brackets, waste coupling 32mm dia of brass Chromium plated, 15mm dia pillar tap of cast copper alloy with capstan head screwed down, high pressure, with or without letter "Hot or Cold" with long screwed shank and fly nuts, 32mm dia, waste pipe low or high density polyethelene of pressure rating 6 Kg/Sqm and PVC connection with PTMT nuts of 15mm dia and 450mm long cutting for and pinning in end of brackets or erecting stand etc. complete all as specified and directed by Engineer - in - Charge.
S&F 10 litre capacity low level PVC valve less, syphonic action type flushing cistern, white, with inlet, ball valve, float and handle including bracket and provision of flush pipe of polythene of high density or PVC, 32mm dia complete all as specified and directed by Engineer-in-Charge.
S&F in repairs 10 litre capacity low level PVC valve less, syphonic action type flushing cistern, white, with inlet, ball valve, float and handle including bracket and provision of flush pipe of polythene of high density or PVC, 32mm dia complete all as specified and directed by Engineer-in-Charge.
S&F in repairs, vitreous china wash hand basin white, flat back size 550x400mm including brackets, waste coupling 32mm dia of brass Chromium plated, 15mm dia pillar tap of cast copper alloy with capstan head screwed down, high pressure, with or without letter "Hot or Cold" with long screwed shank and fly nuts, 32mm dia, waste pipe low or high density polyethelene of pressure rating 6 Kg/Sqm and PVC connection with PTMT nuts of 15mm dia and 450mm long cutting for and pinning in end of brackets or erecting stand etc. complete all as specified and directed by Engineer - in - Charge.
S&F in repairs vitreous china soap dish 160x160x90 mm fixed with screws complete all as specified and directed by Engineer - in - Charge
S&F in repairs, sinks with drainage board made of stainless steel 1 mm thick for kitchen with plugs, washers and waste coupling 40mm bore dia of discharge pipe , waste pipe plain 90cm long suitable for sink waste coupling, waste jali including making grooves , fixing properly or bedding in cement mortar to walll or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed by Engineer - in - Charge.
S&F 15 mm angle valve , cast copper alloy complete all as specified and directed by Engineer-in-Charge.
Cutting for 150 mm pipe into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required complete all as specified and directed by Engineer-in-Charge
Demolition of cement concrete in ground floor and paving n. exc. 15cm thickness (below or above ground level) of any description complete all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed by Engineer - in - Charge
Dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed by Engineer - in - Charge.
M&L for concealed conduit point wiring complete for light /fan with cable 1.5 sqmm(Nominal area) FRLS PVC insulated multistranded unsheathed copper conductor, drawn in and including PVC conduit pipe medium grade 20mm bore,pipe hooks,elbows,junction covers and junction boxes, after cutting in wall chasing for conduits and sinking's for sunken cast iron /pressed steel terminal boxes of suitable length and thickness for mounting switches, sockets, fan regulator with 3mm thick plastic laminated seat cover fixed with brass screws and cup washers, duly grouting and painted with red oxide metal primer and making good disturbed surfaces of wall in CM 1:3 with white wash or existing colour including provision of continuous earth contuity conductor along with point wiring of 1.5 sqmm copper FRLS PVC insulated cable for one light/fan point controlled by one way switch and connected to common earth dolly, complete all as specified and directed by Engr-in-charge.
All as described in Srl item No -146 here in before but for one three pin socket outlet 5 Amp on same board with other switches complete all as specified and directed by Engineer - in - Charge.
All as described in Srl item No. 146 here in before but for one switch socket outlet 3 pin 5/15 Amps on independent board with 2.5 Sqmm (Nominal Area) FRLS PVC insulated multistranded unsheathed copper conductor and continuous earth contuity conductor along with point wiring of 2.5 sqmm copper FRLS PVC insulated copper cable complete all as specified and directed by Engineer - in - Charge.
S & F switch piano flush type 5/6 Amp single pole one way complete all as specified and directed by Engineer - in - Charge
S&F Switch socket combination 2 in 1, 6 pin , 15/16 Amp flush universal type all as spd and directed by Engr in charge.
S & F Socket outlet 5 pin 5 Amps flush type complete all as specified and directed by Engineer - in - Charge.
S & F ceiling rose, surface bakelite 65x50 mm three terminals complete all as specified and directed by Engineer - in - Charge.
S & F in replacement extruded aluminium LED batten channel 20 watt having input voltage AC90-300V, 50Hz, 6500K, with white acrylic cover tube light fitting wall mounted complete with rod, driver and all other accessories including connection with flexible cable copper conductor twin core of size 23/.2 mm upto ceiling rose/connector complete all as specified and directed by Engineer - in - Charge. Make :-Havells cat part No. LUMILINEPLUSBS20WLED865SPCSS, Bajaj cat part No. BCLSBAL 20W CW, Crompton cat part No. CCS-100-20-65-HL2-DP-NWH or equivalent cat part as approved by GE
S & F angle holder insulated body with back plate for conduit fittings complete all as specified and directed by Engineer - in - Charge.
S & F LED lamp 9 W for angle holder complete all as specified and directed by Engineer - in - Charge.
S & F in replacement water tight bulk head fitting, comprision of connector galvanised cast iron back plate, weather proof enamelled gallery, glass well and including 10 watt LED lamp complete all as specified and directed by Engineer-in-Charge. Make :-Havells cat part No. HEXAFT10WLED857SSYMBOPC, Bajaj cat part No. BIBWP 10W LED, Crompton cat part No. LBHP-10-CDL or equivalent cat part as approved by GE
S&F in replacement compact decorative energy efficient LED mirror light fitting with antiglare diffuser and decorative end caps suitable for 1x10 watt fitting 2 ft version including LED lamp 10 watt complete all as specified and directed by Engineer - in - Charge. Make :-Havells cat part No. LUMILINEPLUSBS10WLED865SPCSS, Bajaj cat part No. BCLSB 10 WH, Crompton cat part No. LDL-10-CDL or equivalent cat part as approved by GE
S&F in replacement security light fitting LED TYPE 25 watt with all necessary accessories, Clear transparent acrylic cover, prewired suitable to operated on 230 volt 50 HZ AC & Supply and fixing to wall / on pole including fixing arrangement with suitable galvanized iron pipe 35 mm bore “light grade” brackets 2 mtr length bent to shape to obtained required shape including clamps, nuts / bots / washers etc connecting with suitable flexible copper wire of size 23/0.0076 complete all as specified and directed by Engineer - in - Charge. Make :-Havells cat part No. ENDURAPEARLSL25WLED757SASYTOPCMP, Bajaj cat part No. BRLEP 25 W, Crompton cat part No. LSTS-25-CDL-M or equivalent cat part as approved by GE
S & F sheet metal enclosure for double door DB's made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted SP & N 8 ways, 240 Volts, 200 amps bus bar stove enameled dust and vermin proof suitable for incorporation MCBs and isolators etc complete all as specified and directed by Engineer - in - Charge.
S & F sheet metal enclosure for double door DB's made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounting VTPN 4 ways, 415 Volts, 250 amps bus bar, stove enamelled dust and vermin proof, IP:43 protection suitable for incorporation FP MCCB (v-Tech) N1 Frame upto 125A, isolators and including give connection with wire and cable etc complete all as specified and directed by Engineer - in - Charge.
S&F MCCB TPN 63 Amps with braking capcity 25 kA, fixed TM and 415 volts AC Supply complete all as specified and directed by Engineer - in - Charge.
S & F in replacment MCB ‘B’ series type suitable for 240 volts, AC supply 5 to 30 Amps , single pole with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed by Engineer - in - Charge.
S & F in replacment MCB ‘B’ series type suitable for 240 volts, AC supply 5 to 30 Amps, S P & N with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed by Engineer - in - Charge.
M & L for Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick burried in ground (earth pit not less than 2.25 Mtr deep below normal ground level with top edge of the plate not less than 1.5 Mtrs below normal ground level, connecting to the Galvanised iron earth lead 4 mm dia GI earth wire, by means of bolts, nuts check nuts and washers of galvanised iron and protection by provision of GI medium grade pipe 15 mm bore including provision of concrete pit in PCC (1:2:4) type B1 using 20mm graded stone aggregate with 40mm thick cover of RCC (1:2:4) reinforced with XPM (wieght not less than 4gs/Sqm) and frame of angle iron 25mm x 25mm x 6mm with lugs 02 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20mm bore pipe for watering perforated at the bottom 1.75 meter long placed on top edge of earth plate common salt and charcoal filling test point made out of 40mm x 8 mm FI with fixing arrangements, funnel, wire mesh and earth work in hard dense soil, returning filling in and removal of surplus soil to a distance not exceeding 50 Mtrs all as per electrical Plate No.3 of SSR Part I and connecting to earth test point including taking our unserviceable earthing with all acessories all as specified or indicated including testing on completionall as specified and directed by Engineer - in - Charge.
Supplying, laying and testing in replacement 16 Sqmmx4 core XLPE insulated, heavy duty electric cable with aluminium conductor 1100 V grade conforming to IS-7098 laid in trenches /ducts/fixed on poles wall/ laid under roads/paths/ drain/ culverts or passing through pipes complete all as specified and directed by engineer in charge.
Supplying, laying and testing in replacement 10 Sqmmx 2 core XLPE insulated, heavy duty electric cable with aluminium conductor 1100 V grade conforming to IS-7098 laid in trenches/ ducts/ fixed on poles wall/ laid under roads /paths/ drain/ culverts or passing through pipes complete all as specified and directed by engineer in charge.
S&F Exhaust fan , heavy duty, AC 230 volt of size 280 to 300 mm sweep by grouting both ends in wall upto required length and making hole of suitable size in wall, making good the existing surface and connecting with ceiling roses with and including flexible cable 3 core copper conductor of size 23/.0076 of suitable length with frame. louvers, nuts, bolts etc. including making good disturbed complete all as specified and directed by Engineer - in - Charge. Make- Crompton/Bajaj/Havell's/Orient
Supply, installation, commissioning and testing 3 HP double cylinder car washer 300 ibs psi alongwith 3 phase induction motor complete with pipe, nozzle etc complete all as specified and directrd by Engineer in charge
S&F in replacement direct on line citation motor starter 415V coil sutiable for 2-3 HP induction motor , overload relay range -2.4 - 3.8 Amp, complete with SS enclouser complete all as specified and directrd by Engineer in charge
S&F steel water tubing light grade galvanised 40 mm bore for cable crossing in floors complete all as specified and directrd by Engineer in charge.
Supply & filling/ laying a layer of dry coarse sand 8 cm thick before laying ofcable and 15 cm thick after laying of cable complete all as specified and directed by Engineer - in - Charge. Note:- After punning drain 18 cm will be measured for payment.
M&L for brick protection layer with one brick wide using sub class ‘B’ bricks laid flat across the cable complete all as specified and directed by the Engineer in charge.
Note : Notes : (i) Amount of credit for retrieved materials is mentioned in Sch 'A' Section-II of tender documents in pdf form which will be deducted while acceptance of tender offline.
PAREEK AND COMPANY
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .