CWE PATIALA
HQ COMMANDER WORKS ENGINEER BLDG No 26 NEW LALBAGH PATIALA 147001 Contact 01712200082
REPAIR/ OVERHAULING/ PERIODICAL SERVICE OF DG SETS AND PREVENTIVE MAINTENANCE OF STREET LIGHTS AT MIL STN DAPPAR
2023_MES_615190_1
CWE/PAT/T-27/2023-24
Open Tender
Electrical and Maintenance Works
Works
240 days
DAPPAR
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
AGE(I) DAPPAR
₹90,000
13 Oct 2023
24 Aug 2023
25 Sept 2023
24 Aug 2023
23 Sept 2023
11 Sept 2023
24 Aug 2023 - 6 Sept 2023
Amount
Replacement of defective/detoriated lead Acid batteries with new 12 volts,160 Ah maintenance free batteries complete with SMPS Charger as specified and directed Make Exide/ Luminous/ Amaron
Material & Labour for repair of DG Set 200 KVA, Make : Kirloskar, Ser No 070031, F33M107CI4071 Model No 6/sl150 by replacement of following spares :- (a) Supply & Fix rubber Hoses (tgl 13880 4) of 200 KVA DG Set all as specified and directed. Make: Cat No F6.013.13.0.00 Kiloskar or equivalent in Elofic/Bosch
Supply & Fix rubber Hoses FOR MAIN AIR of 200 KVA DG Set all as specified and directed. Make: Cat No F6. 680.06.0.00, Kiloskar or equivalent in Elofic/Bosch
Supply & Fix Hoses for thermostat of WA of 200 KVA DG Set all as specified and directed. Make: Cat No F6.255.06.0.00, Kiloskar or equivalent in Elofic/Bosch
Supply & Fix Hose (for 200 KVA young RA) of 200 KVA DG Set all as specified and directed Cat No F6.150.03.0.000
Material & Labour for servicing of 200 KVA DG Set control panel operating system locating by fault and replacement of unservicesable part and component complete all and specified & directed as per following:- (a) Repair of worn out internal wiring AC/DC for engine starting ON and OFF with adequate and suitable size copper conductor wire, connect with copper lugs and terminal through protection pipes/casing. (b) Replacement of worn out faulty wiring of control and timer through various control fuse and suitable size copper conductor wire and lugs. (c) Replacement of faulty control fuses, indicated lamps and various type of copper thimble all are deemed to be included in the rate quoted in order to make the system serviceable and in working condition. (d) Testing of the system on load to be included in the quoted rate.
Material & Labour for replacement of relay board UL Make 4 CHA. Cat No F6.865.05.0.00 of 200 KVA DG Set all as specified and directed.
Repair/Replacement of SS Right hand Hinge for Cannopy. Cat No 3H.408.91.0.00 Make Kirloskar
Material & Labour for repair of engine wiring harness SU all as specified and directed. Cat No F6.959.10.0.00
Replacement of LFL Sensor (Low Fuel Level) Cat No 6H.192.14.0.00
Material and labour in repair to self starter 24Volt of 200 KVA DG set as rewinding by using new supper enamelled copper wire of existing size, design and weight and replacement of bush & other unserviceable parts as required including taking down and transportation for repairs & re-fixing in original state after duly repaired as a perfect working condition to the entire satisfaction of Engineer-in-Charge complete all as specified and as directed by Engineer-in-Charge.
Supply only lubricant oil filter NO- F6.436.01.0.00. including its gasket. Make: Kiloskar or equivalent in Elofic/Bosch
Supply only fuel oil filter NO 48.999.20.0.00 including its gasket. Make: Kiloskar or equivalent in Elofic/Bosch.
Supply only Air filter inner & outer NO-F6729.03.00,F6729.05.0.00. with its gasket Kirloskar or equivalent in Elofic/Bosch.
Supply and fix joint for exhaust manifold Cat No. F6.026.03.0.00 all as specified and directed.
Material and labour for anti vibration mounts Cat No. F6.126.02.0.00 ll as specified and directed.
Repair to 24 volts charging alternator from engine of DG set capacity 200 KVA, Kirloskar and carrying out necessary repair including servicing, replacement of carbon bushes, bearings, re-assembling after repair as per existing in a perfect working condition, Cat No Ser.011, to the entire satisfaction of Engr-in-charge
Material & Labour for repair of DG Set 82.5 KVA, Make : Kirloskar, Model No 4H-3555.1320.814 by replacement of following spares :- (a) Supply & Fix rubber Hoses compressor OU of 82.5 KVA DG Set all as specified and directed. Make: Cat No 4H.168..03.0.00 Kiloskar or equivalent in Elofic/Bosch
Supply & Fix Hoses for thermostat BYPASS HOSE OF 82.5 KVA Set all as specified and directed. Make: Cat No 4H.023.02.0.00, Kiloskar or equivalent in Elofic/Bosch
Supply and fix hose for air cleaner Cat No. 4H.227.12.0.00 all as specified and directed
Material & Labour for repair of engine wiring harness 4R1040 Gen all as specified and directed. Cat No 4H.062.20.0.00
Material and Labour for anti vibration mounts 100 Cat No.4H.1716.01.0.00 all as specified and directed.
Supply and fix SS joint for exhaust MA Cat No. P2.106.01.0.00 all as specified and directed.
Material & Labour for servicing of 82.5 KVA DG Set control panel operating system locating by fault and replacement of unservicesable part and component complete all and specified & directed as per following:- (a) Repair of worn out internal wiring AC/DC for engine starting ON and OFF with adequate and suitable size copper conductor wire, connect with copper lugs and terminal through protection pipes/casing. (b) Replacement of worn out faulty wiring of control and timer through various control fuse and suitable size copper conductor wire and lugs. (c) Replacement of faulty control fuses, indicated lamps and various type of copper thimble all are deemed to be included in the rate quoted in order to make the system serviceable and in working condition. (d) Testing of the system on load to be included in the quoted rate.
Material and labour repair to self starter 12Volt of 82.5 KVA DG set as rewinding by using new supper enamelled copper wire of existing size, design and weight and replacement of bush & other unserviceable parts as required including taking down and transportation for repairs & re-fixing in original state after duly repaired as a perfect working condition to the entire satisfaction of Engineer-in-Charge. Cat No SLF.001.00 complete all as specified and as directed by Engineer-in-Charge.
Supply and fix lubricant oil filter ( Primary) No- 06.436.01.0.00 with its gasket. Make Kirloskar or equivalent in Elofic/Bosch
Supply and fix Primary Element Cat No 3H.132.01.0.00 with its gasket. Make Kirloskar or equivalent in Elofic/Bosch
Supply and fix Secondry Element Cat No 3H.132.02.0.00 with its gasket. Make Kirloskar or equivalent in Elofic/Bosch
Supply and fix S Left Hand Hinge for CA Cat No- 3H.408.90.0.00. Make Kirloskar
Repair to 12 volts charging alternator from engine of DG set capacity 82.5 KVA, Kirloskar and carrying out necessary repair including servicing, replacement of carbon bushes, bearings, re-assembling after repair as per existing in a perfect working condition, Cat No Ser.011, to the entire satisfaction of Engr-in-charge
Material & Labour in repair of DG Set 75 KVA, Make : Kirloskar, Model No 4R1040TA, by replacement of following spares :- (a) Replacement burnt out of stop solenoid with ISSC, Cat No 4H.150.01.0.00 all as specified and directed.
Supply & Fix rubber Hoses compressor OU of 75 KVA DG Set all as specified and directed. Make: Cat No 4H.168..03.0.00 Kiloskar or equivalent in Elofic/Bosch
Supply & Fix Hoses for thermostate BYPASS HOSE OF 75 KVA Set all as specified and directed. Make: Cat No 4H.023.02.0.00 , Kiloskar or equivalent in Elofic/Bosch
Supply and fix hose air cleaner Cat No. 4H.227.12.0.00 all as specified and directed
Material & Labour for repair of engine wiring harness 4R1040 Gen all as specified and directed. Cat No 4H.062.20.0.00
Material and Labour for anti vibration mounts 100 Cat No.4H.1716.01.0.00 all as specified and directed.
Material and labour repair to self starter 12Volt of 75 KVA DG set as rewinding by using new supper enamelled copper wire of existing size, design and weight and replacement of bush & other unserviceable parts as required including taking down and transportation for repairs & re-fixing in original state after duly repaired as a perfect working condition to the entire satisfaction of Engineer-in-Charge. Cat No SLF.001.00 Complete all as specified and as directed by Engineer-in-Charge.
Material & Labour for KG934 controller with 4-2 Cat No 02.026.04.0.00 all as specified and directed.
Material & Labour for servicing of 75 KVA DG Set control panel operating system locating by fault and replacement of unservicesable part and component complete all and specified & directed as per following:- (a) Repair of worn out internal wiring AC/DC for engine starting ON and OFF with adequate and suitable size copper conductor wire, connect with copper lugs and terminal through protection pipes/casing. (b) Replacement of worn out faulty wiring of control and timer through various control fuse and suitable size copper conductor wire and lugs. (c) Replacement of faulty control fuses, indicated lamps and various type of copper thimble all are deemed to be included in the rate quoted in order to make the system serviceable and in working condition. (d) Testing of the system on load to be included in the quoted rate.
Supply and fix lubricant oil filter ( Primary) No- 06.436.01.0.00 with its gasket. Make Kirloskar or equivalent in Elofic/Bosch
Supply and fix Primary Element Cat No 3H.132.01.0.00 with its gasket. Make Kirloskar or equivalent in Elofic/Bosch
Supply and fix Secondry Element Cat No 3H.132.02.0.00 with its gasket. Make Kirloskar or equivalent in Elofic/Bosch
Repair to 12 volts charging alternator from engine of DG set capacity 75 KVA, Kirloskar and carrying out necessary repair including servicing, replacement of carbon bushes, bearings, re-assembling after repair as per existing in a perfect working condition, Cat No Ser.011, to the entire satisfaction of Engr-in-charge
Replacement of LFL Sensor (Low Fuel Level) Cat No 6H.192.14.0.00 all as specified and directed
Material & Labour in repair of DG Set 50 KVA, Make : Kirloskar, Model No 5H-3845/1420122 & 4H-3555.1320814 by replacement of following spares :- (a) Supply and fix lubricant oil filter ( Primary) No- 06.436.01.0.00 with its gasket. Make Kirloskar or equivalent in Elofic/Bosch
Supply and fix Primary Element Cat No 3H.132.01.0.00 with its gasket. Make Kirloskar or equivalent in Elofic/Bosch
Supply and fix Secondry Element Cat No 3H.132.02.0.00 with its gasket. Make Kirloskar or equivalent in Elofic/Bosch
Supply & Fix Hoses for thermostate BYPASS HOSE OF 50 KVA Set all as specified and directed. Make: Cat No 4H.023.02.0.00, Kiloskar or equivalent in Elofic/Bosch
Supply and fix L.O Supply hose (FIP) M10 Cat No. 4H.006.01.0.00 all as specified and directed
Supply and fix hose (pipe to water pump) Cat No. 4H.073.0z2.0.00 all as specified and directed.
Material & Labour for repair of engine wiring harness 4R1040 Gen all as specified and directed. Cat No 4H.062.20.0.00
Material and Labour for anti vibration mounts 100 Cat No.4H.1716.01.0.00 all as specified and directed.
Supply and fix SS joint for exhaust MA Cat No. P2.106.01.0.00 all as specified and directed.
Material & Labour for servicing of 50 KVA DG Set control panel operating system locating by fault and replacement of unservicesable part and component complete all and specified & directed as per following:- (a) Repair of worn out internal wiring AC/DC for engine starting ON and OFF with adequate and suitable size copper conductor wire, connect with copper lugs and terminal through protection pipes/casing. (b) Replacement of worn out faulty wiring of control and timer through various control fuse and suitable size copper conductor wire and lugs. (c) Replacement of faulty control fuses, indicated lamps and various type of copper thimble all are deemed to be included in the rate quoted in order to make the system serviceable and in working condition. (d) Testing of the system on load to be included in the quoted rate.
Replacement of LFL Sensor (Low Fuel Level) Cat No 6H.192.14.0.00
Repair to 12 volts charging alternator from engine of DG set capacity 50 KVA, Kirloskar and carrying out necessary repair including servicing, replacement of carbon bushes, bearings, re-assembling after repair as per existing in a perfect working condition, Cat No Ser.011, to the entire satisfaction of Engr-in-charge
Material & Labour in repair of DG Set 50 KVA, Make : Ashok Leyland Ser No WFHM 395874, WFHM 395873 & WFHM 396079 by replacement of following spares :- (a) Supply & Fix lubricant oil filter HSN No 84212300 with its gasket. Make Ashok Leyland or equivalent in Elofic/Bosch
Supply & Fix fuel filter HSN No 84212300 with its gasket. Make Ashok Leyland or equivalent in Elofic/Bosch
Supply & Fix Air filter safety HSN No 84212300 with its gasket. Make Ashok Leyland or equivalent in Elofic/Bosch
Supply & Fix Air filter primary HSN No 84212300 with its gasket. Make Ashok Leyland or equivalent in Elofic/Bosch
Supply and fix hose HSN Code 40091100 all as specified and directed.
Supply and fix Diesel Pipe HSN Code 40091100 all as specified and directed.
Replacement of stopper HSN Code 40091100 all as specified and directed.
Dismantling and taking out burnt out 12 volts charging alternator from engine of DG set capacity 50 KVA DG Set and carrying out necessary repair including servicing, replacement of carbon bushes, bearings, re-assembling after repair as per existing in a perfect working condition HSN Code 998729 to the entire satisfaction of Engr-in-charge
Material & Labour for repair of DG Set 31.25 KVA, Make : Ashok Leyland Ser No WFHM 393453 & WFHM 393452 by replacement of following spares :- (a) Supply & Fix lubricant oil filter HSN No 84212300 with its gasket. Make Ashok Leyland or equivalent in Elofic/Bosch
Supply & Fix fuel filter HSN No 84212300 with its gasket. Make Ashok Leyland or equivalent in Elofic/Bosch
Supply & Fix Air filter safety HSN No 84212300 with its gasket. Make Ashok Leyland or equivalent in Elofic/Bosch
Supply & Fix Air filter primary HSN No 84212300 with its gasket. Make Ashok Leyland or equivalent in Elofic/Bosch
Supply and fix hose HSN Code 40091100 all as specified and directed.
Supply and fix Diesel Pipe HSN Code 40091100 all as specified and directed.
Replacement of stopper HSN Code 40091100 all as specified and directed.
Dismantling and taking out burnt out 12 volts charging alternator from engine of DG set capacity 31.25 KVA DG Set and carrying out necessary repair including servicing, replacement of carbon bushes, bearings, re-assembling after repair as per existing in a perfect working condition HSN Code 998729 to the entire satisfaction of Engr-in-charge
Material & Labour in repair of DG Set (1010KVA silent (radiator type) Cummins KTA38G5 & Alternator - 1010KVA Stamford, DG 1 Engine No 25418954, Alternator No N16J403681, DG 2 Engine No 25421283, Alternator No N16I362553, DG 3 Engine No 2518952, Alternator No N16I362628 by replacement of following spares - (a) Material & Labour for 'B' Check Kit KV HE, KIT3238516, Cat No 84212300 all as specified and directed by Enge-in-Charge
Material & Labour Kit Air Cleaner Elements, KIT3238665 (K, QSK,V Series) all as specified and directed by Enge-in-Charge
Material & Labour for Inhibitor Corrosion 205 Ltrs, Cat NO 3816981, HSN Code - 38200000 all as specified and directed by Enge-in-Charge
Material & Labour for Inhibitor Corrosion 10 Ltrs, Cat NO 4926654, HSN Code - 38119000 all as specified and directed by Enge-in-Charge
Material & Labour for Radiwash 5 Liters Cat No AX1013508, all as specified and directed by Enge-in-Charge
Material & Labour for Valvorine Premium Blue 7800 Plus 1/55 Ltrs Cat No 506655 HAN No 27101980 all as specified and directed by Enge-in-Charge
Material & Labour for Oil Extract BAG Cat No JKM OEM all as specified and directed by Enge-in-Charge
Supply & fixing in replacement Digital panel/Display board of DG set Panel with initial software calibration of monitor all as specified and directed by Engr-in-charge
Material & Labour water seperator as existing all as specified and directed by Enge-in-Charge
Material & Labour in repair of DG Set 30 KVA, Mahindra, DG 1 Engine No N3A17AT24038, DG 2 Engine No N3F173A17AT24030, 8 by replacement of following spares :- (a) Supply and fix service kit element of fuel filter, HSN Code - 84212900 all as specified and directed
Supply & fix only engine oil filter HSN Code all as specified and directed
Supply and fix safety Air element 4575GM, HSN Code 84219900 wih its gasket. Make : Mahindra or equivalent in Elofic/Bosch
Supply and fix primary element 75 HP, HSN Code 84219900 wih its gasket. Make Mahindra or equivalent in Elofic/Bosch
Supply and fix belt fan HSN Code 40101110 all as specified and directed
Supply and fix belt Gen/Alt Cogged (Hilton) HSN Code 40101110 all as specified and directed
Supply and fix fuel supply pipe, HSN Code 40091100 all as specified and directed.
Supply and fix fuel return Pipe HSN Code 40091100 all as specified and directed.
Supply and fix radiator hose inlet HSN Code 87089900 all as specified and directed.
Material & Labour for repair of DG Set 62.5 KVA, Mahindra, DG 3 Model No 4905GMAC2 by replacement of following spares;- (a) Supply and fix service kit element of fuel filter, all as specified and directed
Supply & fix only engine oil filter HSN Code all as specified and directed
Supply and fix safety Air element including its gasket. Make : Mahindra or equivalent in Elofic/Bosch
Supply and fix primary element including its gasket. Make Mahindra or equivalent in Elofic/Bosch
Supply and fix belt fan all as specified and directed
Supply and fix belt Gen/Alt Cogged (Hilton) all as specified and directed
Supply and fix fuel supply pipe all as specified and directed.
Supply and fix fuel return Pipe all as specified and directed.
Supply and fix radiator hose inlet all as specified and directed.
Dismantling and taking out burnt out 12 volts charging alternator from engine of DG set capacity 30 to 1010 KVA DG Set and carrying out necessary repair including servicing, replacement of carbon bushes, bearings, re-assembling after repair as per existing in a perfect working condition HSN Code 998729 to the entire satisfaction of Engr-in-charge
Dismantling and taking out stopper switch solenide and carrying out necessary repair including servicing, re-assembling after repair as per existing in a perfect working condition to the entire satisfaction of Engr-in-charge
Supply and fix in replacement Voltage Monitoring Relay (VMR) 3 Phase Digital (Porton) for DG Set 31.25 KVA, Make : L&T Cat No SM800 with suitable wiring etc all as specified and directed
Supply and fix in replacement Engine start relay Cat No TE-150, Make: Teknika for DG Set 31.25 KVA, with suitable wiring etc all as specified and directed
Supply and fix in replacement On delay timer 220volts, Cat No 110DT4, Micon 175, Make: L&T for DG Set 31.25 KVA, with suitable wiring with all accessaries etc all as specified and directed
Supply and fix in replacement Ply relay 12V DC, 32A for DG Set 31.25 KVA, with wiring and thimbling etc all as specified and directed
Supply and fixing in replacement MCB SP 6 -32 Amps,10 KA, 'C' series 240 V ISI marked complete all as specified and directed by Engr-in-charge.
Supply and fixing in replacement MCB SPN 06-32 Amps,10 KA 'C' series 240 V ISI marked complete all as specified and directed by Engr-in-charge.
Supply and fix in replacement Battery charger 12 Volt DC for DG Set 31.25 KVA, with suitable wiring etc all as specified and directed
Supply and fix in replacement Push buttons Red and Green Cat No EP1FAC08 Make: L&T for DG Set 31.25 KVA, with wiring and thimbling etc all as specified and directed
Taking down radiator complete from engine of DG set capacity 30/31.75/50/75/82.5/200 /250KVA at site and carrying out repairs/ cleaning and re fixing in original state after duly repaired in a perfect working condition to the entire satisfaction of Engineer-in-Charge and repair shall be comprising of the following:- (a) Removing dust from fins interior & exterior portion clean to parts by air cleaner and wash out by using maic solution-01 job. (b) Carrying out soldering as required to make leak proof-01 job. (c) Replacement of upper & lower gasket by new one-01 job replacement of nuts, bolts, clamps, hoses etc as required -01 job (d) Replacement of rusted nuts, bolts,clamps,hoses etc all as required.
Taking down radiator complete from engine of DG set capacity 1010 KVA at site and carrying out repairs/ cleaning and re fixing in original state after duly repaired in a perfect working condition to the entire satisfaction of Engineer-in-Charge and repair shall be comprissing of the following:- (a) Removing dust from fins interior & exterior portion clean to parts by air cleaner and wash out by using maic solution-01 job. (b) Carrying out soldering as required to make leake proof-01 job. (c) Replacement of upper & lower gasket by new one-01 job replacement of nuts, bolts, clamps, hoses etc as required -01 job (d) Replacement of rusted nuts, bolts,clamps,hoses etc all as required.
Repair/replacement of AVR model TAVR-3A-S/F KG Cat No. F6.0814.11.0.00 ll for 200 KVA, Kirloskar DG Set as specified and directed.
Repair/Replacement of kirloskar green AVR Cat No. 2H.811.32.0.00 for 82.5 KVA DG Set of Kirloskar all as specified and directed.
Supply and Topping up of coolant in radiator of DG set after draining out old water and cleaning of radiator of any capacity/type complete all as specified and directed by Engr-in-charge.
Supply & Fix in replacement defective/detoriated lead Acid batteries with new 24V, 32 Ah maintenance free batteries complete with SMPS Charger Make:Cummins Cat No AX1013235 or equivalent in EXIDE/ SF
Material & Labour earthing complete with and including galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm surrounded by a mixture of charcoal and salt in alternate layers burried directly in ground vertically in a pit of depth not less than 2.25 m deep below ground level with top edge of earth plate at a depth of not less than 1.5 m below ground level, connected to using galvanised iron strip 25×4mm as earthing lead by means of nuts, bolts, checknuts and washers made out of galvanised iron, 15 mm bore (light grade) GI pipe for protection of earthing lead, 20 mm bore (light grade) GI pipe for watering with funnel, wire mesh and including necessary excavation and earth work, PCC 1:2:4 type B-1 pit and 50 mm thick RCC M-25(Design mix) reinforced with XPM (weight not less than 3 kg/sq m) pit cover, C.I frame, charcoal and comman salt filling in alternate layers, complete all as shown and specified in electrical plate No. 5 of SI Part-I.
Repair to existing earthing and earthing strip of any size by replacement of existing nuts, bolts, checknuts and washers with new items as specified and directed
Suuply & Fix GI strip of size 32x 6 mm buried in ground or fixed on wall connecting at ends, jointing alongwith suitable size PVC insulator etc complete all as specified and directed.
Supply and topping up of Distilled water in lead acid battery of DG set at AGE(I) Dappar station. Complete all as specified and as directed by Engr-in-Charge.
Supply and fix in replacement of detoriated/damaged Battery lead with new cable assembly battery lead Cat part no:0416-0639 Make Cummins or equivalent Finolex/Havells
Material & Labour for cleaning of DG sets including removing of oil greese and spot washing carefully with soda water including preparation of old painted surface and painting to the DG sets of capacity 100 to 250 KVA with two coats of spray painting of approved make and colour of first grade paint and marking SM/MES No as per existing all as specified and directed
Material & Labour for Silver painting heat resistance including preparation of surface of Exhaust pipe to DG Set of 100 KVA to 250 KVA all as specified and directed
Material and labour in replacement for rubber insulation matting 1 mtr wide class A upto 3.3 KV, chequered having thinkness 20mm. Make : Electromat or equivalent Joyti/National
Supply and laying of Synthetic insulating mat of size 2x1 mtr and 19mm thick all as specified of make as specified
Material and labour in replacement for rope asbestos of size 10-12mm dia thermal with standing capacity complete all as directed by Engr-in-Charge
Material and labour for Tank cleaning and repairing of fuel tank including, soldering, cleaning, all as specified and directed
Supply, laying, connecting and testing or passing through pipe, XLPE 1100 volts grade heavy duty underground cable with PVC insulated aluminium stranded conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire 10 sq mm 2 core normal cross sectional area including taking down old unservicable cable complete all as specified and as directed by Engineer-in-Charge. Note : All minor spares such as cable gland, aluminium lugs etc & minor jobs such as cutting, welding etc is deemed to be included in the quoted rates.
All as per item No 2 here in before but of 4 core 16 sqmm.
All as per item No 2 here in before but of 4 core 25 sqmm.
All as per item No 2 here in before but of 3.5 core 35 sqmm.
Supply & Fixstreet/security light bracket made out of 40mm dia light grade 1.5mtr bent to shape for fixing on any type of pole/wall with clamps nuts and bolts complete all as directed by engr-in-Charge. Note:Cost of necessary GI items such as reducer, coupler, etc. required to be fitted with GI bracket so as to proper fittment of luminaries with bracket is deemed to be included in the quoted rate.
Supply and fix weather proof aluminum conductor 4 sqmm 2 core, flat cable for connection from looping box to street light fitting.
Supply & Fix in replacement of old unvs box Street light control junction box 280x170x130mm equipped with IP66 protection from cable looping box to the connector of the luminarie made out of FRP sheet and arrangement 3 phase 4 wire system with R.Y.B.& N studs and control for incoming & outgoing cables with MCB SP 10 Amps 230 volts with neutral link including flat iron 25x3 mm “D” clamps (2 Nos) suitable for mounting of box to pole /Angle of required size & shape including bolts nuts & washers.”NOTE: - The quoted rate is deemed to be inclusive of cost of suitable size incoming & outgoing cable glands & lugs.
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m depth for laying of CI / GI pipes iiue in trenches and getting out in soft/loose soil complete all as specified and directed by Engr-in-Charge .
Removing excavated soil to a distance not exceeding 50 mtr and depositing where directed at level not exc 1.5 mtr above the starting point complete all as specified and directed by Engr-in-Charge.
Returning, filling in trenches including , leveling water and all raming in layers not exc 25 cm in soft / loose soil, complete all as specified and directed by Engr-in-Charge
Material and labour sand cushioning (dry sand) to underground cable for cable protection 23 cm thick in two layers (8 cm thick before laying of cables and 15 cm thick after laying the cable and punning down the sand to 18 cm thickness.). Complete all as specified and as directed by Engineer-in-Charge. (Note:- Only punned thickness 18 cm of sand shall be measured for payment purposes).
Supplying and laying un-reinforced precast concrete cable cover, class LV type 1 flat, size 250mm x 150mm x 40mm all as specified and directed by engr -in-charge.
Taking down old unservicable fitting and Supply & Fix 120 watt LED Flood light luminaire 230V AC outdoor type equippid with IP66 protection of epoxy powder coated CRCA MS housing with epoxy powder coated aluminium heat sink with system wattage, with 120 degree view angle,>100 lumen/watt,luman maintenance>90% at 50,000hrs,colr temperature of 5000-6500K,> color rendering and LM80 test compliance.The driver must be integral APFC and constant current type having THD<15% and power factor>0.95 with short circuit protection,open protection,reverse polarity protection,high voltage protection complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size.The LED used in fitting is of same manufacturer.
Supply & fix power contactor 3 pole, type ML-3, with 2 NO + 2 NC aux contacts with standard coil voltage 415 volts, Rating 40 Amp as per Cat No. 90721 of L & T or equivalent of Siemens/ Schneider/ABB including testing connecting commissioning complete all as specified and directed.
Material and labour for application of two coats of aluminium paint on steel tubular/rail pole externally after removal of old paint, rust, dust, oil, grease or any other foreign deposits by paint removers or burning off by blow lamps, cleaning with scrapers and chemicals for removal of rust for any number of coats of any width or girth incl. numbering of poles in black base & white letters paint and incld. painting five no. strips upto 30 cm on bottom of pole with black and red colour paint alternately all as specified and directed by Engr-in-Charge.
Supply and fixing energy efficient LED street light fitting of 70W pressure die cast aluminium housing/body, heat resistant clear toughened glass, better optics for uniform distribution street/Roadway luminaire, with driver, including electric connection, complete fitting with all accessories and following specifications, including taking down old unserviceable light fitting any type with old bracket complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 105 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) IP rating : Minimum IP65. (g) IK rating : Minimum IK07 (h) Built in potted LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection 10 kV (inbuilt + extended) (l) CCT : 5700 K. (m) CRI : Morethan 70 (n) Lens - High Efficiency wide angle lens. (o) BIS Approved fixtures and driver (p) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily).
Supply and fixing LED LUMINARIE, pressure die cast aluminum housing, 45 watts capacity, 240V, IP 65 class, with suitable in-built electronic driver complete all as directed and specified by Engr-in-charge. NOTE - Cost of all minor spares and jobs required for fixing of light fixture on wall and for electrical connections are deemed to be included in the quoted rate.
Dismantling and taking out steel poles/struts/PCC poles of any size incld demolition of PCC foundation complete.
Material and labour for erection of internally and externally hot dipped galvanized 3 MM thick steel sheet (grade S355JO) 7 Mtr long 'smart poles' of octagonal cross-section with integral camouflaged junction box for incorporating control gears with flush door with necessary locking arrangements, having base plate-220x2260x12MM to be grouted on suitable size shallow foundation with M-15 concrete with 750 MM long 04 Nos. 20MM dia. bolts and 4MM anchor plate, mounted with pole top mounting spigot type hot galvanised single arm street light mounting bracket Single arm bracket 1000 mm in length all as per instructions and technical specifications of OEM and to the complete satisfaction of Engr-in-Charge.
Material & Labour for cement concrete 1:4:8 type D- 2 using 40mm graded crushed stone aggregate in foundation filling & mass concrete for poles/struts/stays assembly complete all as specified and directed by Engr-in-Charge.
Material & Labour for cement concrete 1:2:4 type B - 1 using 20mm graded crushed stone aggregate in coping pedestal to poles including provision of necessary frame work finishing the expossed surface even and smooth complete all as specified and directed by Engr-in-Charge.
Dismantling of unserviceable cross arms of MS Chanel/angle sections etc complete all as specified and directed.
Material and labour for cross arms, bracing, supports, clamps and back plates fabricated from structual steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shape or size as indicted and inclusive of one primer coat one under coat and two finishing coat of aluminium paint.
Restringing and Fixing ACSR Conductor reinforced of any size to proper sag incl binding on insulator all as specified and as directed by Engr-in-Charge
Cutting & trimming of tree branches any girth and size around overhead lines to a clear distance 1.5 mtr both sides of overhead line with in a 25 to 40 mtrs span gap of HT/LT lines including clearing the site all as specified and directed by the Engr-in-Charge.
Material and labour for stay assembly complete with accessories as shown in electric plate No.I including loop type insulator, stay clamps etc complete all as specified & directed with diameter of stay 20 mm of stay rod complete all as specified & directed. Note: - Loop type insulator, PCC foundation, Exc & earth work & GI stay strand will be measured and paid seperately under relevent items of Sch 'A'
Material and labour for earthing with galvanised iron earth plate of size 600x600x6mm thick buried directly in ground not less than 2.25m below normal ground level, earth plate packed on all sides with charcoal mixed with salt in alternate layers of 15 cm thickness connected by galvanised iron earth earth strip 32x6mm soldered & riveted to earth plate, galvanised iron earth strip will be provided by using 50mm bore galvanised iron pipe (light grade) earth plate to transformer body and neutral or test point of transformer, including flat iron clamp 25x4mm including bolts, nuts and washers complete including watering galvanised iron pipe 20 mm dia 'Light grade' 2.5mm long the earthing includes PCC pit including necessary earth works and disposal of surplus soil to a distance not less than 50m, chamber of PCC 1:4:8 type D-2 using 40mm graded stone aggregate, coping shall be of PCC 1:3:6 type C-I using 20mm graded stone aggregate, RCC pit cover 50mm thick in1:2:4 type B-I using 20mm graded stone aggregate, rein forced with 8mm dia @ 15cm c/c complete all as shown on sketch No 3 of SSR-I of 2009 and as specified and as directed by Engr-in-Charge.
Supply & Fix in repairs 5-32 A SP MCB, 10 kA 'C' series, 240 V AC, 50 Hzcomplete switch gear/components in various APFC panels all as specified and directed by Engr-in-Charge
Supply & Fix in repairs 63A TPN MCB, 10 kA 'C' series, 415 V AC, 50 Hz complete switch gear/ components in various APFC panels all as specified and directed by Engr-in-Charge
Supply and relplace existing u/s indicating lamp LED type suitable to operate on 230 volts AC Supply of R/Y/B colour as per site requirement all as specified and directed.
Supply & Fix in replacement Single function 3 phase LED ammeter with accuracy Class 1.0, Flush mounting 96 x 96 mm, Input voltage measurement range 50-520 VAC (P-P), CT/PT site programmable all as specified.
Supply & Fix in replacement Single function 3 phase LED voltmeter with accuracy Class 1.0, Flush mounting 96 x 96 mm, Input voltage measurement range 50-520 VAC (P-P), CT/PT site programmable all as specified.
Supply and replace existing unserviceable CT as that of existing ratio and model suitable for 3 phase supply as specified and as directed by Engr-in-Charge.
Painting to electric control panel of E/M installations by cleaning the existing old paint with the help of mechanical tools such as wire brush, scraper and sand paper from the surface of panel and painting the prepared surface with two coat of synthatic enamel paint of approved shade over a coat of red oxide primer complete all as specified abd specified.
Supply and fix cable jointing kit for 1100 V grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3.5 core XLPE, armoured, Aluminium conductor cable of size upto 16 to 35 sqmm, core outdoor type and taking down fault complete all as specified and directed by Engr-in-Charge.
Material and labour for making bore to road width for providing GI pipe medium/light grade both end socketed for passing armoured cable complete all as specifed.
Material and labour for galvanized iron tubing size 40 mm bore (Light grade) with all necessary fittings laid in trenches under road crossing or fixed on poles / walls / under floors for cable protectioncomplete all as specfied and as directed complete all as specified and as directed by Engineer-in-Charge.
Supply & Fix in repair LED 30W solar street light fitting suitable for solar street light all as specified & directed by Engr-in-Charge.
Jai Maa Electrical Works
M/S Sonu Traders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .