Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.7 CrAccepted-Finance | ₹1.7 Cr | L1 | Accepted-Finance L1 |
| 2 | L2₹2.1 Cr+₹32.0 L (18.3%)Rejected-Finance | ₹2.1 Cr+₹32.0 L (18.3%) | L2 | Rejected-Finance L2 |
| 3 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 4 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| Sl No | Description | Qty | Unit | G B R INFRASTRUCTURE L2 | S NINGAPPA L1 |
|---|---|---|---|---|---|
| 1.00 | Removing of existing old or broken wash basin / urinals/ Indian Water closet/ European Water closet and disposing it with all cost and conveyance labour for all items of work, HOM with all lead and lift, loading and unloading, transportation charges and all other incidental charges etc., complete as per specification and directions of the Engineer-in-charge of the work. | 39 | Each | 350 ₹16,107 | 83.9 ₹3,861 Lowest |
| 2.00 | Dismantling of flushing cistern of all types (C.I./PVC/Vitreous China) including stacking of useful materials near the site and disposal of unserviceable materials to the appropriate disposal area as per direction of Engineer-in-charge. | 15 | Unit | 250 ₹4,425 | 92.29 ₹1,633.5 Lowest |
| 3.00 | Demolishing cement concrete manually/ by mechanical means including disposal of material to the appropriate disposal area as per direction of Engineer-in-charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)as per specification and directions of the Engineer-in-charge of the work. | 90 | Cum | 750 ₹79,650 | 671.19 ₹71,280 Lowest |
| 4.00 | Dismantling tile / Mosaic work in floors and roofs laid in cement mortar includ ing stacking material to the appropriate disposal area as per direction
of Engineer-in-charge. For thickness of tiles 10 mm to 25 mm | 180 | Sqm | 50 ₹10,620 | 25.17 ₹5,346 Lowest |
| 5.00 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground to the appropriate disposal area as per direction of Engineer-in-charge. | 500 | Sqm | 50 ₹29,500 | 31.88 ₹18,810 Lowest |
| 6.00 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by engineering incharge. | 200 | Cum | 400 ₹94,400 | 293.64 ₹69,300 Lowest |
| 7.00 | Demolishing brick tile covering in terracing including stacking of serviceable material and disposal of unserviceable material to the
appropriate disposal area as per direction of Engineer-in-charge. | 100 | Sqm | 50 ₹5,900 Lowest | 50.34 ₹5,940 |
| 8.00 | Chipping unsound weak concrete material from slabs. Beams, columns & roofs upto 50mm by manual means or by standard power driven
percussion type including cleaning reinforcement with wire brush complete as per direction of Engineer incharge of work. | 150 | Sqm | 50 ₹8,850 Lowest | 109.07 ₹19,305 |
| 9.00 | Disconnecting damaged overhead/terrace PVC water storage tank of any size from water supply line and removing from the terrace including
shifting at ground level as per direction of Engineer-in-charge. | 10 | Each | 300 ₹3,540 | 125.85 ₹1,485 Lowest |
| 10.00 | Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. | 20 | Sqm | 300 ₹7,080 | 125.85 ₹2,970 Lowest |
Tender Value
₹2.2 Cr
EMD Value
₹3.3 L
Closing Date
17 Nov 2025, 3:30 pmClosed
Registrar
IISc Bangalore
Renovation and repair works of NSQA16, NSQA22, NSQA49, NSQA51, NSQA56, NSQA58, NSQA61, NSQA67, NSQA69, NSQA73, NSQB20, NSQB25, NSQB28, NSQB44, NSQB72, B621, B634,B635, B636, B644, B656, B658, B662, B664, B669, B672, B685, B696,B708, A855, A872, A
2025_IISC_883193_1
IISc/Tender-CIV-14/2025-26
Open Tender
Civil Works
Works
365 days
IISc Bangalore
As Per Tender Documents
2 documents required · 2 mandatory
₹0
₹3.3 L
MS Teams online
19 Jan 2026
28 Oct 2025
18 Nov 2025
29 Oct 2025
17 Nov 2025
11 Nov 2025
6 Nov 2025
Amount
Removing of existing old or broken wash basin / urinals/ Indian Water closet/ European Water closet and disposing it with all cost and conveyance labour for all items of work, HOM with all lead and lift, loading and unloading, transportation charges and all other incidental charges etc., complete as per specification and directions of the Engineer-in-charge of the work.
Dismantling of flushing cistern of all types (C.I./PVC/Vitreous China) including stacking of useful materials near the site and disposal of unserviceable materials to the appropriate disposal area as per direction of Engineer-in-charge.
Demolishing cement concrete manually/ by mechanical means including disposal of material to the appropriate disposal area as per direction of Engineer-in-charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)as per specification and directions of the Engineer-in-charge of the work.
Dismantling tile / Mosaic work in floors and roofs laid in cement mortar includ ing stacking material to the appropriate disposal area as per direction of Engineer-in-charge. For thickness of tiles 10 mm to 25 mm
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground to the appropriate disposal area as per direction of Engineer-in-charge.
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by engineering incharge.
Demolishing brick tile covering in terracing including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge.
Chipping unsound weak concrete material from slabs. Beams, columns & roofs upto 50mm by manual means or by standard power driven percussion type including cleaning reinforcement with wire brush complete as per direction of Engineer incharge of work.
Disconnecting damaged overhead/terrace PVC water storage tank of any size from water supply line and removing from the terrace including shifting at ground level as per direction of Engineer-in-charge.
Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge.
Repairs to plaster in patches of 2.5 m2 and less in walls, ceilings 10 to 20mm thick in cement mortar 1:4 including cutting the patches in proper shape and replastering the surface of the wall including disposal of rubbish with a lead of 50m including curing cost of materials, labour, complete as per specification as per direction of Engineer-in-charge.
Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge.
Taking out doors, windows and clerestory window / cup board shutters (steel or wood) including stacking to the appropriate disposal area as per direction of Engineer-in-charge.Of area 3 m² and below
Repair to existing ply wood ward-robes with 19mm plywood, beading,laminate and all necessary including cost of materials labour, lead, complete as per specifications.
Taking out existing wooden door shutter, repair by cutting, painting etc.and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge.
Repairing door and window frames with wood to the required size.
Repairing and fixing shutters (panelled or glazed) to doors, windows, ventilators and cupboards.
Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure in cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of Engineer incharge of work.
Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates as per specification as per direction of Engineer-in-charge.
Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge.
Providing 12 mm cement plaster with cement mortar 1:6 (1 cement:6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding,including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
Extra for providing and mixing water proofing material in cement plaster/concrete work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineer in-Charge.
Extra for making chequers of approved pattern on 1:2:4 cement concrete floors, steps, landing, pavements etc.
Providing and fixing sliding arrangement in racks/ cupboards/cabinets shutter by with stainless steel rollers to run inside C or E aluminium channel section (The payment of C or E channel shall be made separately)
Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately): 30mm thickness as per specification and directions of the Engineer-in-charge of the work.
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. Size 62 x 100mm (Fixtures shall be paid for separately)
Providing and fixing unplasticised PVC connection pipe with brass unions : 45 cm length, 15 mm nominal bore
Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in Charge.
Providing and fixing chromium plated brass casement window fastener with necessary screws etc. complete. For steel windows
Providing and fixing chromium plated brass casement stays (straight peg type) with necessary screws etc. complete : 250 mm weighing not less than 280 gms for steel windows
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 25mm dia pipes
Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work
Removing white or colour wash by scraping and sand papering and preparing wall surface smooth including necessary repairs to scraches etc. Complete as per specifications and as per directions of Engineer in charge
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge
Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound) content less than 50 g/L, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge.
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :One coats on old work as per specifications and as per directions of Engineer in charge
Finishing walls with Acrylic Smooth exterior paint of required shade : Old work (Two coats applied @ 1.67 l/ 10 m²) on existing cement paint surface including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic ompound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge.
Providing and fixing 40 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.
Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame around door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per specification. -do- 30 mm thick both side commercial
Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete :100x58x1.90mm
Providing and fixing Float glass panes of nominal thickness 4 mm (weight not less than 10kg/ m²)
Providing and fixing UV stabilised 2 mm thick plain FRP sheet
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 453x357 mm
Providing and fixing weld mesh of required width in mesh size 25x25 mm made of 3 mm dia including welding to MS section complete as per the direction of engineer- in-charge.
Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, upto 25 metre height, above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge.
Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications
Providing and placing on terrace ( At all floor levels ) polyethene water storage tank, IS:12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, out let and overflow pipes but without fitting and the base support for tank.
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fix tures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid
Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. 10 litre capacity - White
Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal dia pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931
Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
Providing and fixing S.C.I. gully or nahani grating 100 mm dia,stain less steel grating
Providing and fixing Towel rail 600mm length made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class: Economy
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 100 mm diameter
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Stainless steel kitchen sink - without drain board 610x460mm bowl depth 200 mm.
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 610x510 mm bowl depth 200 mm
Providing and fixing to wall, ceiling and floor SWR PVC pipes 6.00kg/sq.cm working pressure 75mm outside diameter of approved make with pipe fittings, wall clips, making good the wall, ceiling and floor, including cost of all materials, labour charges, HOM of equipments and testing complete as per specifications and as directed by Engineer-in-charge.
Providing and fixing to wall, ceiling and floor SWR PVC pipes 6.00kg/sq.cm working pressure 110mm outside diameter of approved make with pipe fittings, wall clips, making good the wall, ceiling and floor, including cost of all materials, labour charges, HOM of equipments and testing complete as per specifications and as directed by Engineer-in-charge.
Providing and fixing to wall, ceiling and floor SWR PVC pipes 6.00kg/sq.cm working pressure 63mm outside diameter of approved make with pipe fittings, wall clips, making good the wall, ceiling and floor, including cost of all materials, labour charges, HOM of equipments and testing complete as per specifications and as directed by Engineer-in-charge.
Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments. 110 mm dia PVC Elbows
Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments. 75mm dia PVC Elbows
Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments. 63mm dia PVC Elbows
Supply and delivery at site special moulded variety PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments. 110 mm dia PVC Tee
Supply and delivery at site special moulded variety PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments. 75 mm dia PVC Tee
Supply and delivery at site special moulded variety PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments. 63 mm dia PVC Tee
Supply and delivery at site special moulded variety PVC bend as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments. 110 mm dia PVC BEND
Supply and delivery at site special moulded variety PVC bend as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments. 75 mm dia PVC BEND
Supply and delivery at site special moulded variety PVC bend as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments. 63 mm dia PVC BEND
Providing and grouting tile joints, Cutting the tile joints with the help of cutting machine (width 3mm-15mm) and filling with of matching shade, using three component Epoxy based tile joint filler, non-sag waterproof grout, chemical and UV resistance, Pot life ≤ 60 mins, VOC (EPA 24) < 8gm/kg and water absorption after 7 days < 0.5g Joints shall be clean, dry, free from dirt, etc prior to application. Apply tile grout using a rubber trowel/grout floater, press firmly into joints, ensure complete fill and remove excess grout from surface using suitable method. The work shall be carried out as per the directions of the Engineer in charge.
Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm
Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3coarse sand) and jointing with grey cement slurry @ 3.3kg per m2,including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete.
Providing & supplying Floor & Surface cleaners Non corrosive with chemicals Hydrochloric acid, Butyl oleytamine and others which are water soluble and capable of removing hard and soft stains and dirt as per direction of Engineer in charge of work
Providing & supplying Toilet cleaner of reputed make capable of killing bacteria, germs as per direction of Engineer in charge of work
Providing and applying two coats of wax polishing to existing mosiac floor as following:- a) Polishing the surface with 2nd grade polish stone and filling the open joints with required white cement and colour pigment. b) Polishing with fine quality polishing stones and cleaning with water. c) Providing and applying two coats wax and polish mixed with petrol and polishing with coir bundles and finishing with floor polish machine. the work is executed as per the directions of Engineer-in-charge.
Providing and fixing 2 in 1Bib Cock with wall Flange of approved make as per the direction of Engineer in charge
Providing and fixing Health Faucet of required size approved make as per the direction of Engineer in charge
Providing and fixing solid plastic seat with lid for pedestal type W.C. pan complete. A) White solid plastic seat with lid
Providing and fixing in position fully glazed for windows shutters with Honne wood stiles and rails of 30mm. thick 75mm wide in single shutters with 4mm thick plain glass fixed with wooden beading including cost of materials, labour charges, usage charges complete as per specifications. (excluding cost of fixtures)
Providing and fixing aluminium tower bolts, ISI marked, anodised (an odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete
Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc. 125x65x2.12mm
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion: Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications.
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications.
Providing and fixing S S wire mesh of average width of aperture 1.4 mm and nominal dia of wire 0.63 mm complete as per the direction of Engineer - In - Charge.
Providing and fixing concealed lock of approved brand and manufacture for aluminium window as per the direction of Engineer-in-charge
Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge. SS Aldrop 16mm dia, 200 mm
Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete
Providing and supplying cupboard shutter with 19mm thick one side Architect recommended decorative laminate (1mm thick) and other side balancing lamination(preferably white) on factory pressed BWP grade marine ply as per IS 710 of approved brand complete as per direction of engineer in- charge.(Payment for providing and fixing auto closing hinges shall be paid separately)
Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete
Providing and fixing magnetic catcher of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc. complete.
Providing and fixing stainless steel 304 grade soft closing hinges with two hole fixing & 165 degrees turning option for Wardrobe, Doors, Kitchen & other utilities of reputed make with screws etc. complete as per directions of Engineer- in - charge
Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications.
Providing and fixing Pillar Cock made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class Economy
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 g.
Providing and fixing C.P. brass waste 32 mm
Providing and fixing C.P. brass waste 40 mm
Providing Waterproof treatment to the cracks using 1 coat of bondcoat of SBR latex and Cement at the ratio 1:1 and then preparing Cement Mortar of 1:3 admixed with SBR latex at a dosage of 15% of Cement. SBR latex confirming to BS 6319 part 2:1983 & ASTM C 190-85. Cure for 5 days. Apply singlecomponent, cold applied, water based acrylic and UV resistant water proofing & protector conforming to ASTM D 412-1992 & ASTM E 1980-01. The surface shall be prepared free of dust, fungus, loose & hard particles etc.. The cracks are sealed with crack x-shrink free sealing paste as per direction of Engineer in charge.
Providing and fixing Wall face unplasticised rigid rain water pipes conforming to IS 13592 type A including jointing with seal ring conforming to IS 5382 leaving 10mm gap for thermal expansion (i)single socketed 100mm diameter with including clamps and fittings.
Providing and Applying Polyurethane hybrid liquid applied GRIHA certified Waterproofing coating with flutyne protection technology, single component, cold applied, water based acrylic and UV resistant water proofing treatment to the Existing Roof having Tile or any non-porous surface applied @ 1.5 l/m2 in 2 coats to achieve 1mm DFT, having tensile strength with (45 gsm + 45 gsm) glass fibre mesh 4N/mm2 confirming to ASTM D 412; Elongation at break ≥ 300% and Crack bridging ability up to 3mm, SRI Index 106 as per ASTM E1980-01, Water permeability @5 bar – Nil as per EN12390 - 8:2019, including surface preparation, priming the surface with single component high-performance waterborne tile primer which is suitable for non - porous surface at a rate of 0.083 L/m2 and spreading (45 gsm + 45 gsm) glass fibre mesh of 2.5 mm x 2.5 mm sandwiched between the first and second coat completely as per specification. The finished cost to include surface preparation, making coving at Junction, treatment of cracks completely as per specification.
Providing and laying water proofing treatment to the Water tanks & Liquid Retaining structures with two component acrylic polymer modified cementitious waterproofing membrane with minimum elongation of 50% applied @ 1.5 kg/m2 for internal side waterproofing in two layers with waiting period of 4-6 hrs per layer and food grade epoxy coating in two coats certified by CFTRI Mysuru, including surface preparation completely as per specification
Providing and Applying Acrylic Co Polymer single component specially designed waterproof protective coating that prevents damp patches on walls without any dilution at rate of 0.25kg/m2 in 2 coats to achieve total dry film thickness of 170 microns DFT. The material having followed technical properties: crack bridging ability up to 1mm as per EN 1062, Tensile strength ≥ 2N/mm2 as per ASTM D 412, adhesion strength 1.5N/mm2 as per ASTM D4541. The finished cost including surface preparation completely as per specification.for interior walls.
Providing and fixing Angle cock with wall flange made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class
Providing and fixing special quality bright finished brass cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete.40mm
Cleaner for cleaning work
Plumber
Carpenter Class I for repair works
UNSKILLED Mazdoor light work
Mason or Brick layer Class -1 for mason works
Welder for welding works
Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI > 80. Power Input: 220-240V@ 50/60Hz & Power factor >0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 2' - 9/10 W Make: Philips, Bajaj, Crompton
Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI > 80. Power Input: 220-240V@ 50/60Hz & Power factor >0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 20/22 W Make: Philips, Bajaj, Crompton
Supplying and fixing of LED bulk head of 10W with IP65 protection and IK08 impact resistance suitable for surface and wall mounting applications. Make: Philips, Crompton
Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders
Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. 6A SP Switch
Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. 6A Two Way Switch
Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. 6A Three Way 5 Pin Socket
Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. 6A Three Pin Top
Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. 6A Bakelite Ceiling Rose
Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. 6A Lamp Holder
Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. 6A Bell Push
Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. 16A SP Switch
Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. 16A Three Way 5 Pin Socket
Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. Electronic stepped regulator
Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. 32A Bakelite DP
Supplying and fixing of modular switch & connected accessorieson existing modular switch plate as per IS 3854 and IS 1293 - 6 Amps one way Switch Make: Anchor, Legrand, MK
Supplying and fixing of modular switch & connected accessorieson existing modular switch plate as per IS 3854 and IS 1293 - 6 A Two Way Switch Make: Anchor, Legrand, MK
Supplying and fixing of modular switch & connected accessorieson existing modular switch plate as per IS 3854 and IS 1293 - 6 A Three Way socket Make: Anchor, Legrand, MK
Supplying and fixing of modular switch & connected accessorieson existing modular switch plate as per IS 3854 and IS 1293 - 16 Amps one way Switch Make: Anchor, Legrand, MK
Supplying and fixing of modular switch & connected accessorieson existing modular switch plate as per IS 3854 and IS 1293 - 6/16 A Universal Socket Make: Anchor, Legrand, MK
Supplying and fixing of modular switch & connected accessorieson existing modular switch plate as per IS 3854 and IS 1293 - TV / Telephone Socket Make: Anchor, Legrand, MK
Supplying and fixing of modular switch & connected accessorieson existing modular switch plate as per IS 3854 and IS 1293 - Stepped Fan Regulator Two Module Make: Anchor, Legrand, MK
Supplying and fixing of modular switch & connected accessorieson existing modular switch plate as per IS 3854 and IS 1293 - 6 A Bell Push Make: Anchor, Legrand, MK
Supplying and fixing of modular switch & connected accessorieson existing modular switch plate as per IS 3854 and IS 1293 - 32 A DP Switch Make: Anchor, Legrand, MK
Supplying and flush mounting powder coated / galvanizedmetal box suitable for mounting modular switch plates. The boxshould be firmly flush mounted after due groove cutting inBrick/Stone/C.C wall 1-2 Way Make: Anchor, Legrand, MK
Supplying and flush mounting powder coated / galvanizedmetal box suitable for mounting modular switch plates. The boxshould be firmly flush mounted after due groove cutting inBrick/Stone/C.C wall 3 Way Make: Anchor, Legrand, MK
Supplying and flush mounting powder coated / galvanizedmetal box suitable for mounting modular switch plates. The boxshould be firmly flush mounted after due groove cutting inBrick/Stone/C.C wall 4 Way Make: Anchor, Legrand, MK
Supplying and flush mounting powder coated / galvanizedmetal box suitable for mounting modular switch plates. The boxshould be firmly flush mounted after due groove cutting inBrick/Stone/C.C wall 6 Way Make: Anchor, Legrand, MK
Supplying and flush mounting powder coated / galvanizedmetal box suitable for mounting modular switch plates. The boxshould be firmly flush mounted after due groove cutting inBrick/Stone/C.C wall 8 Way Make: Anchor, Legrand, MK
Supplying and flush mounting powder coated / galvanizedmetal box suitable for mounting modular switch plates. The boxshould be firmly flush mounted after due groove cutting inBrick/Stone/C.C wall 12 Way Make: Anchor, Legrand, MK
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1-2 Module Make: Anchor, Legrand, MK
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3 Module Make: Anchor, Legrand, MK
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Module Make: Anchor, Legrand, MK
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module Make: Anchor, Legrand, MK
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module Make: Anchor, Legrand, MK
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 12 Module Make: Anchor, Legrand, MK
Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete. 12" Sweep (300 mm) Make: Bajaj, Crompton, Havells
Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5A.ceiling rose with sufficient length of 23/0.0076i nch PVC insulated twin core wire.
Supplying ...litres capacity vertical/horizontal type wall mounting Electrical water heater with 22 SWG copper/SS sheet metal inner Container tinned inside Fiber body outside, filled with glass wool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. The Inner container shall have direct immersion type copper tube nickel plate. 2kW capacity element with a neon indicator fitted with 20A capacity 25 to 85 degree Centigrade range thermostat. The water heater shall completely be wired with 40/0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided with heavy gauge brackets for wall mounting. 5 Star With Fibre body-25 L Capacity Make: Racold, Bajaj, Crompton
Erection charges for fixing a...litres capacity wall mounting electric geysers using bolts,flat at one end nut and washers at the other end for through bolts and nuts and washers with150x450x600mm back plate and wiring complete with 15A 3 pin top. up to 30 Litres
Supplying and fixing/replacement of heating element for Geyser/Boiler. 2 kW Capacity
Releasing an unserviceable thermostat and providing in its place a new 20 A capacity 25 inch to 85 inch range thermostat.
Suppling & Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or wiring with specified IS-694:confirming to latest amendments including terminations with copper lugs 1.5 Sq mm - Make: Finolex, Polycab, Havells
Suppling & Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or wiring with specified IS-694:confirming to latest amendments including terminations with copper lugs 2.5 Sq mm - Make: Finolex, Polycab, Havells
Suppling & Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or wiring with specified IS-694:confirming to latest amendments including terminations with copper lugs 4.0 Sq mm - Make: Finolex, Polycab, Havells
Suppling & Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or wiring with specified IS-694:confirming to latest amendments including terminations with copper lugs 6.0 Sq mm - Make: Finolex, Polycab, Havells
Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length and copper lugs in a wood/PVC round block. complete for each outlet. Short point upto 3 m from tapping point to outlet via switch box
Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length and copper lugs in a wood/PVC round block. complete for each outlet. Medium point above 3 m upto 6 m from tapping point to outlet via switch box
Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length and copper lugs in a wood/PVC round block. complete for each outlet. Long point above 6 Mtr upto 10 Mtr from tapping point to outlet via switch box
Supplng and drawing Co-Axial TV Cable RG-6 grade, 0.7mm, solid copper conductor PE insulated, shielded with fine tinned copper braid and protection with PVC sheath in the existing surface/ecessed steel/PVC conduit as required Make: Havells, Polycab
Supplying heavy gauge PVC Conduit Pipe mm dia2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface andrun with 18 SWG GI fish wire run throughout the conduit wherever necessary. 19/20 mm dia 2 mm thick
Supplying heavy gauge PVC Conduit Pipe mm dia2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface andrun with 18 SWG GI fish wire run throughout the conduit wherever necessary. 25 mm dia 2 mm thick
Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300 mm .... etc. as required. 20 mm
Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300 mm .... etc. as required. 25 mm
Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws. Ding Dong Bell -Make:Anchor, Havells/equivalent
Supplying 4mm thick plastic sheet with necessary nitches for fixing switches, regulators etc, and fixing on existing wooden or metal box using N.F. screws.
Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. 12 Way SP & N- Double door Make: Legrand, L&T, Schneider
Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materialsand 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32Amps SP -Make: Legrand, L&T, Schneider
Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materialsand 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DP -Make: Legrand, L&T, Schneider
Supplying and fixing of AC type RCBO on existing MCB distribution board using necessary fixing materials, C curve, capacity of 10 KA and complete wiring as required confirming ot IEC 60947 - 40A double pole RCBO, 240 V, 30mA sensitivity Make: Legrand, L&T, Schneider
Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 20A single phase Class-1 Accuracy with Temper Proof Energy Meter. Make: L&T
Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DGsets etc.using 40mmdia 2.9mm thick 2.5m long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover.The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber.The connection from the electrode is to be established through GI strip using GI bolts and nuts.
Supplying and laying 6 SWG G.I. wire at 0.50 metre belowground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
Providing and fixing 6 SWG dia GI wire on surface or in recess for loop earthing as required
Providing and fixing 6 SWG dia GI wire on surface or in recess for loop earthing along with existing surface / recessed conduit/submain wiring /cable as required
Removing of existing switch boards, energy meter, old aluminium wiring, old earth conductor pipe, from existing quarters and shifting to store and cleaning of fans, exhaust fans, shifting of fans from iisc store to respective quarters, shifting of old fans from quarters to Store etc as instructed by the Engineering-in-charge
Releasing the existing fan checking, testing and installation at the same place.
Releasing the existing FTL Fitting all capacities, checking, testing and installing at same place
Supply and fixing single pole blanking plate in the existing MCB DB complete etc., as required
Supply and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required
G B R INFRASTRUCTURE (BID ID -3318384)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Document
0.40 MB
Tender Documents
Tender Documents • 3.66 MB
BOQ
BOQ • 0.52 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .