Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.4 LAccepted-AOC | L1 | Accepted-AOC BEING L1 BIDDER | |
| 2 | L2₹38.3 L+₹96,507.80 (2.59%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹38.9 L+₹1.6 L (4.18%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹39.4 L+₹2.1 L (5.72%)Rejected-Finance INDEX NO D 35 ADG NEI GUWAHATI OLD HASIMARA POST HASIMARA DIST ALIPURDUAR WB PIN 735215 | ALIPURDUAR | WEST BENGAL | 735215 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹39.6 L+₹2.3 L (6.11%)Rejected-Finance MES CHOWPATHY PO HASIMARA DISTT JALPAIGURI PIN 735215 WB | HASIMARA | JALPAIGURI | WB | 735215 | L5 | Rejected-Finance Other than L1 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
16 Nov 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) HASIMARA
GE (AF) HASIMARA, PO-HASIMARA, DIST- ALIPURDUAR, PIN-735215
ADDN/ALTN TO BLDG NO. P-38 AT AF STN HASI MARA
2024_MES_681400_1
C/8826/2024-25/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) HASIMARA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) HASIMARA
₹80,000
Yes
22 Nov 2024
25 Oct 2024
18 Nov 2024
25 Oct 2024
16 Nov 2024
9 Nov 2024
Amount
Taking down cement plaster on brick or concrete surfaces including racking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed..
M&L for brick work with fly ash bricks, old size, straight or curved on plan exc 6 mtr mean radius built in CM (1:6), complete all as specified and directed.
M&L for cutting openings, through brick walls for door, window and other openings or enlarging existing openings converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core, etc.. to store and rubbish not exc. 50m, complete all as specified and directed.
M&L 15mm thick rendering in CM (1: 6) on fair faces of brick work or concrete surfaces finished surfaces even and smooth, complete all as specified and directed.
M & L for rendering 15mm thick (10mm + 5mm) in two coats on fair faces of brick work or concrete surfaces of wall in CM (1:4), mixed with integral water proofing compound at top layer as per manufacturer's instructions and finished the surface even and fair without using extra cement, complete all as specified and directed. (Note : WPC shall be measured and paid separately against respective item as supply only.)
Supply only liquid water proofing compound conforming to IS: 2645 - 1975 specification, complete all as directed
M&L for preparation of newly plastered wall surfaces and applying two coats of oil bound distemper over a coat of chalk whiting, complete all as specified and directed.
M&L for preparation new plastered surfaces of wall and applying two coats of 100% premium acrylic exterior emulsion paint, alkali & fungal resistance, of required shade over a coat of exterior emulsion primer, as per manufacturer's instructions, complete all as specified and directed.
M&L for non skid ceramic designed coloured tiles 10mm thick (square/rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement of match the surfaces over and including 15mm thick screed bed in CM (1:6), complete all as specified and directed.
M&L for non skid ceramic designed coloured tiles 10mm thick (square/rectangular) vertical surface skirting/dado area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement of match the surfaces over and including 10mm thick rendering in CM (1:4), complete all as specified and directed.
Dismantling of old steel window/ventilator/rolling shutter of any description, complete all as specified and directed.
M&L for framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging, also fastening and fixing, complete all as specified and directed.
S & F powder coated (minimum thickness of powder coating 50 micron) aluminium anodised door comprising of frame of size 101.60mm x 44.6mm x 2.4mm thick push/pull type glazed door shutter having top and bottom section of size 83 x 44.5 x 2.4mm and 100 x 44.5 x 2.4mm thick respectively, styles section of size 80 x 44.5 x 2.4mm thick and lock rail of size 100mm x 44.5mm x 2.4mm thick including necessary jointing cleat, glazing clips, rubber packing, anodised aluminium snap beading, screws of suitable size including 5mm thick tinted sheet glass in both panel, hinges, mortice lock, stays & aluminium anodised handle of suitable size, etc, complete all as specified and directed.
S&F powder coated (minimum thickness of powder coating 50 micron) aluminium work for doors, windows, ventilators and partitions (fixed portions) with extruded built up standard tubular sections/appropriate 'Z' sections and other section of approved make conforming to IS-733 and IS-1285, fixing with dash fasteners of required dia and size including necessary filling up the gaps at junctions, i.e. at top bottom and sides with required EPDM rubber/neoprene gasket. aluminium sections shall be smooth rust free straight mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing/paneling, CP brass/stainless steel screws, complete all as specified and directed.
S&F 3mm thick ACP (aluminium composite panel) sheet, wooden finish, in aluminium frame including all nessesary fittings, complete all as specified and directed.
S&F 10mm thick toughened glass, as in partition, fixed to aluminium section, including cutting to shape, drilling holes, as required, complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for and removing from site, complete all as specified and as directed.
M&L for PCC (1:2:4) type B1 (using 20mm graded crushed stone aggregrate) in roof kerbs or mud stops etc., rounded or chamfered on edges, complete all as specified and directed.
S&F mild steel framed roof trusses, purlins, crane gantries, rails and fastening and heavy brackets framing (beam, tee, angle, channel or flat section) including distance pieces, cleats etc, Fe-290 (Gde E-165), complete all as specified and directed.
M&L for preparation of new steel or iron surfaces of any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint (1st grade quality) over a coat of red oxide primer, complete all as specified and directed.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including nainital or similar pattern roof coverings, complete all as specified and directed.
S&F pre painted galvalume aluminium zinc coating, GI based corrugated steel sheet 0.50mm thick, of any colour, having tensile strength of 550 Mpa as in roof covering /cladding to wall fixed with self tapping screws, complete all as specified and directed.
S&F pre painted galvalume aluminium zinc coating, GI based plain steel sheet 0.50mm thick, of any colour, having tensile strength of 550 Mpa as in roof covering /cladding to wall/valley gutters/ridges etc, fixed with self tapping screws, complete all as specified and directed.
S&F for 600mm x 600mm GI frame work for seamless ceiling comprising of Gl perimeter channnel 0.55mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/intermediate channel 0.9mm thick having two equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457mm centre to centre including providing 4mm non asbestos fibre cement building E-boards fixed or laid/inserted to GI frame work with screws for fixing in 600mm x 600mm grid, complete all as specified and directed.
Taking down carefully point wiring of any type, size and description from hard/ teak wood batten/through pipes/casing capping (light, fan, sockets and socket outlets etc) including removal of battens, pipes, plug sockets, socket outlets, switches, shades, ceiling roses, light fittings etc. complete and making good the disturbed surface to match with existing, complete all as specified and directed.
M & L for point wiring complete with PVC insulated unsheathed, 1100 volts grade cable 1.5 Sqmm (nominal area) FRLSH type multi stranded copper conductor, single core drawn in surface tupe PVC conduit, medium grade, (ISI marked), heavy duty of adequate size including its accessories not less than 20mm dia rigid PVC conduit, medium grade, ISI marked including all conduit accessories with and including concealed modular box of suitable size for mounting modular switch, sockets, fan regulator etc including 1.5 Sqmm FRLSH type PVC insulated unsheathed cable multi-stranded copper conductor as continuous earth wire and connected to earth dolly as required at site & including chases cutting & making good disturbed surface & applying finishes to match existing surface etc. for one light/fan point controlled by one, one way switch single pole, complete all as specified and directed. Note: - (i) Rate quoted shall deemed to be included for cost of modular box (as per nuber of module of outer cover) and concealed in wall including cutting and sinking of boxes and making good to the walls. (ii) Provision of cover plates/sorroundings of any module/blank plates as per site requirement shall deemed to be included in the quoted unit rate.
All as per item No 27.00 here-in before but for one 3 pin 5 Amps modular socket outlet on same board controlled by other switch, complete all as specified and directed.
All as per item No 27.00 here-in before but for one 3 pin 5 Amps modular socket outlet on the independent board controlled by other swtich, complete all as specified and directed.
All as per ser item No. 27.00 here in above but for one 16 Amp 6 pin modular socket outlet independent point including PVC cable 4 Sqmm FRLSH type copper stranded conductor along with 4 Sqmm continious PVC insulated unsheathed standard copper conductor cable FRLSH type for as earth wire, complete all as specified and directed.
S&F modular switch, single pole, one way, 5/6 Amps 240 volts, one module, complete all as specified and directed.
S&F modular switch, single pole, one way, 15/16 Amps 240 volts, one module, complete all as specified and directed.
S&F modular socket outlet, multipurpose, having provision for 3 pin, 5/6 Amp and 2 pin combined, 2 module, complete all as specified and directed.
S&F modular socket outlet, multipurpose, having provision for 3 pin, 15/16 Amp and 3 pin combined, 2 module, complete all as specified and directed.
S&F modular front plate with frame, 2 module, white colour, complete all as specified and directed.
S&F modular front plate with frame, 3 module, white colour, complete all as specified and directed.
S&F modular front plate with frame, 4 module, white colour, complete all as specified and directed.
S&F modular front plate with frame, 8 module, white colour, complete all as specified and directed.
S&F PVC wall mounted fan, 400mm sweep, white colour with BLDC motor and remote including fixing on wall, completes all as specified and directed.
S&F ceiling rose of size 65 x 50mm surface bakelite 240 Volts, three terminal, complete all as specified and directed.
S&F LED lights fitting 1x 20 W, 220V, AC decorative box with driver, LED rod complete connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and directed.
S&F LED luminaire 600mm x 600mm, 30 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size, complete all as specified and directed.
S&F sheet metal enclosure for double door MCB DBs, Triple Pole & Neutral (TPN), 4 way, 415 volts, IP 43 & IK 09 with metal door fixed on wall with din rail, neutral and earth bar, fixed in proper position, complete all as specified and directed.
S&F sheet metal enclosure for double door MCB DBs, Single Pole & Neutral (SPN), 8 way, 415 volts, IP 43 & IK 09 with metal door fixed on wall with din rail, neutral and earth bar, fixed in proper position, complete all as specified and directed.
S&F RCBO for earth leakage, over load and short - circuit protection 32 Amp, double pole 100 mA, completes all as specified and directed.
S&F MCB SP 6 to 32 Amps, 240V, 10 KA, 'C' curve, including connection of testing, completes all as specified and directed.
S&F MCB SPN 6 to 32 Amps, 10 KA, 'C' curve, including connection of testing, complete all as specified and as directed.
S&F MCB 63 Amps, 4 pole, 10 KA, 'C' curve, including connection of testing, complete all as specified and as directed.
S&F power unit suitable for load max upto 3.5 KW including sockets 25 Amps and 04 module box for mounting of power unit and power socket, complete as specified and directed.
Supply and draw sub main wiring of two run 6.0 sqmm single core (FRLSH) PVC insulated, unsheathed multistranded copper conductor cable 1100 Volt grade, drawn through and including concealed rigid PVC conduit (ISI marked), heavy duty, of not less than 20mm size including all conduit accessories including one run of 6.0 sqmm single core (FRLSH) PVC insulated unsheathed copper earth continuity including taking down existing sub-main wiring, complete all as specified and directed. Note:-(i) Three runs of cable and one run of PVC conduit and its accessories shall be measured as one length of sub main. (ii) Unit rate shall deemed to be included for cutting chases for conduits and sinking for boxes and making good to wall/floors etc.
Supply and draw sub main wiring of two run 4.0 sqmm single core (FRLSH) PVC insulated, unsheathed multistranded copper conductor cable 1100 Volt grade, drawn through and including concealed rigid PVC conduit (ISI marked), heavy duty, of not less than 20mm size including all conduit accessories including one run of 4.0 sqmm single core (FRLSH) PVC insulated unsheathed copper earth continuity including taking down existing sub-main wiring, complete all as specified and directed. Note:-(i) Three runs of cable and one run of PVC conduit and its accessories shall be measured as one length of sub main. (ii) Unit rate shall deemed to be included for cutting chases for conduits and sinking for boxes and making good to wall/floors etc.
M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6.0mm thick buried directly in ground vertically to a depth not less than 2.25 meter below ground level with top edge of earth plate at a depth not less than 1.5 meter below ground level, earth plate surrounded by 15cm thick packed layer of charcoal dust and common salt, connected to galvanized earth lead wire 4mm thick dia by means of bolts, nuts and washers of galvanized iron or steel and thimbles and other end of the earth strip connected to earthing test point/equipment and protected by galvanized iron pipe light grade 20mm bore, up to earthing test point/equipment fixed with required number of mild steel clamp made out of 25mm x 3mm flat iron and perforated water pipe 20mm dia. GI medium grade of length 2.25 meter and top with socket & plug and bottom connected to earth plate by slit and two bolts/nuts/washers, PCC chamber in PCC (1:2:4) type B-1 and 40mm thick pre-cast RCC (1:2:4) type B-0 cover reinforcement with 40mm x 40mm x 6mm MS angle iron frame, excavation & earth work complete all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009 including dismantling of old unserviceable earthing of any description, complete all as specified and directed. Note: - (i) GI strip up to earth test point/equipment is included in this item. (ii) Outer edge of earth pit chamber shall be 1.5 meter away from the outer edge of PCC chamber.
S&F LED street light fitting 35/36 Watt 230 V AC complete with IP 65/66 protection alogwith fixing accessories on wall/pole, complete all as specified and directed.
Excavation in trenches not exceeding 1.5 metre wide and not exc 1.5 metre in depth and n. exc. 10 Sqm on plan for foundation of pole/stay, or cable trenches etc and getting out in soft/loose soil, complete all as specified and directed.
Returning filling in spreading, leveling watering and well ramming in layers not exceeding 25cm in soft/loose soil, complete all as specified and directed.
Removing excavated materials to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 metre above the starting point in any type of soil, complete all as specified and directed.
Supply & laying double walled corrugated (DWC) HDPE duct pipe of 50mm dia (inner dia) conforming to IS approved colour complete with fittings for cable protection, complete all as specified and directed.
Supply, laying, jointing and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 Sqmm 3.5 core including taking down old unserviceable UG cable of any description, complete all as specified and directed.
Note: An amount of Rs.94,624.00 on account of Credit Schedule for schedule 'A' part - II shall be deducted from the total amount of BOQ to arrive at the contract sum.
M/S ASHOK ENTERPRISE (BID ID -3166857)
M/S DEY ENTERPRISE (BID ID -3166121)
M/S ANNI ENTERPRISE (BID ID -3165861)
M/S MANODEEP CONSTRUCTION (BID ID -3166637)
M/S BIJAY KUMAR SHIVA (BID ID -3166406)
DEEP NIRMAN (BID ID -3167003)
M/S. KUMAR CONSTRUCTION CO. (BID ID -3166345)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .