| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.8 LAccepted-AOC | L1 | Accepted-AOC Being L1 bidder | |
| 2 | L2₹36.0 L+₹33,925 (0.95%)Rejected-Finance PLOT NO 52 BAKSHI NAGAR JAMMU 180001 J K | JAMMU | JAMMU | JAMMU AND KASHMIR | 180001 | L2 | Rejected-Finance Being other than L1 bidder | |
| 3 | L3₹36.4 L+₹70,405 (1.97%)Rejected-Finance R O NAUSHERA DISTT RAJOURI J K 185151 | NAUSHERA | RAJOURI | JAMMU AND KASHMIR | 185151 | L3 | Rejected-Finance Being other than L1 bidder | |
| 4 | L4₹36.9 L+₹1.3 L (3.62%)Rejected-Finance | L4 | Rejected-Finance Being other than L1 bidder | |
| 5 | L5₹37.1 L+₹1.5 L (4.20%)Rejected-Finance | L5 | Rejected-Finance Being other than L1 bidder |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
18 Sept 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 862 EWS
GE 862 EWS PIN-913862 C/o 56 APO
Repair to roof treatment and plastering of certain bldgs under AOR of AGE B/R Dett-A under GE 862 EWS
2023_MES_614929_1
GER-34/2023-24
Open Tender
Civil Works
Item Rate
180 days
GE 862 EWS
Class D a (i)
9 documents required · 9 mandatory
₹500
GE 862 EWS
₹1 L
Yes
17 Oct 2023
22 Aug 2023
20 Sept 2023
22 Aug 2023
18 Sept 2023
4 Sept 2023
Amount
Dismantling of plain or corrugated steel sheeting, any gauge, thickness including Nanital or similar pattern roof covering complete all as specified and directed.
Dismantling of asbestos cement (corrugated, semi corrugated etc) sheeting in roof covering, complete all as specified and directed.
Dismantling of timber scantling 40 Sqcm and over in section, in any position as in unframed or framed work complete all as specified and directed.
S&F for rolled mild steel in roof trusses (framed), trussed, purlins, crane gantries, rails and fastening and heavy brackets framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats, etc. conforming to Fe-290-W (Gde - E-165 quality A complete all as specified and directed.
S&F for Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of approved colour having tensile strength 550 MPa as in roof covering/cladding to wall fixed with self tapping screws / 'L' or 'J' hooks including side and end lap as per manufacturer’s instructions, complete all as specified and directed.
S&F for Pre-painted galvalume aluminium zinc coated GI based plain steel sheet 0.50mm thick of approved colour having tensile strength 550 MPa as in ridges, fixed with self tapping screws / 'L' or 'J' hooks including side and end lap as per manufacturer’s instructions complete all as specified and directed.
S&F for 4mm thick designer cement fibre ceiling board in ceiling fixed with screw as per manufacturers instructions , laid over and including hot dipped galvanised iron in post grid with 24mm wide T section exposed flanges which shall be powder coated white. The frame work shall comprise of main runner made from 0.33 mm thick galvanised steel sheet of size 24 x 32 x 300 mm spaced at 12 mm centres securely fixed to the structural soffits by approved hangers at 1200mm maximum centres. Hangers of GI wire 4 mm dia to be fixed by approved rawl plug, level adjusters and screws etc. The last hanger at the end of each main runner shall not be greater than 450 mm from adjacent wall flush fittings of 1200 mm long screws Tee with (double stiching) to interlocked between main runners at 600 mm centre to centre from 1200 x 600 mm modules cross tee longer than 600 mm modules to be formed by fittings 600 mm long cross tee, tee perimeter wall angle shall be of 0.45 mm thick galvanised steel of size 19 x 19 mm and 300 mm long of white colour all as per insturctions including dismantling of existing ceiling board etc, complete all as specified and directed.
Demolition of brickwork or stone / boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone-work and precast concrete articles, complete all as specified and directed.
M&L for stone walling of random rubble masonry, uncoursed, well bonded, bedded and soilidly hearted, built in cement mortar 1:6, complete all as specified and directed.
Description all as per srl item No. 09 above but except stone. NOTE: Old stone retrieved from demolition shall be used.
M&L for extra over stone walling of any type of stone for hammer dressing to face stones and dressing of face beds with maximum depression on face from straight edge held against the dressed surface n exc 40 mm and joints, as specified, of random rubble walling, uncoursed or brought upto courses, complete all as specified and directed.
M&L for brick work with sub class ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6, complete all as specified and directed.
Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed.
M&L for rendering 20 mm thick in cement mortar 1:6 on other than fair faces of stone masonry work, finished even and smooth without using extra cement, complete all as specified and directed.
M&L for rendering 10 mm thick in cement mortar 1:6 on brick masonry surface finished even and smooth without using extra cement, complete all as specified and directed.
M&L for rendering 10 mm thick in cement mortar 1:3 on concrete surface of ceiling, finished even and smooth without using extra cement, complete all as specifed and directed.
M&L for rendering 20 mm thick in cement mortar 1:4 on other than fair faces of stone masonry work, finished even and smooth without using extra cement, complete all as specified and directed.
M&L for rendering 15 mm thick in cement mortar 1:4 on brick masonry surface finished even and smooth without using extra cement, complete all as specified and directed.
M&L for preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of white cement primer, complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper over a coat of alkali resistant primer and a coat of Birla wall care putty 1.5mm thick, complete all as specified and directed.
M&L for preparation of new plastered surfaces of ceiling and applying two coats of oil bound distemper over a coat of alkali resistant primer and a coat of Birla wall care putty 1.5mm thick, complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall and applying three coats of white wash, complete all as specified and directed.
M&L for preparation of old decorated brick / concrete plastered / un-plastered surfaces of walls, pillars, cornices etc by brooming down with steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and treating oil and greasy spots and applying one coat of cement base paint on walls, pillars, cornices etc, complete all as specified and directed.
M&L for preparation of old decorated brick / concrete plastered/un-plastered surfaces of walls, pillars, cornices etc by brooming down with steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and treating oil and greasy spots and applying two coat of oil emulsion distemper including one coat of wall care putty 1.5mm thick, complete all as specified and directed.
M&L for preparation of old decorated brick / concrete plastered/un-plastered surfaces of ceiling by brooming down with steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and treating oil and greasy spots and applying two coat of oil emulsion distemper including one coat of wall care putty 1.5mm thick, complete all as specified and directed.
M&L for preparation of old decorated brick / concrete plastered/un-plastered surfaces of walls, pillars, cornices etc by brooming down with steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and treating oil and greasy spots and applying two coats of white wash, complete all as specified and directed.
M&L for preparation of new or previously untreated steel surfaces over 10cm in width or grith of any description and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floor and paving n exc 15 cm thickness below or above the ground level, complete all as specified and directed.
M&L for 40mm plain cement concrete, type B-1, 1:2:4, (using 20 mm graded crushed stone aggregates) as in padding on roof surface to maintain proper slope, finishing cement concrete surface even and smooth using extra cement, complete all as specified and directed.
Complete removal of existing water proofing treatment over RCC roof, projections of any thickness, any type by stripping out old tar felt over roofs, parapets, chimney stacks etc laid horizontally or vertically including taking out layer of cement plaster etc and cleaning the surface with wire brush including removing debris from the site and depositing in low lying area where directed and providing following :- (a) Rendering 10mm thick in cement mortar 1:4 on concrete roof surfaces and finish the surface even and smooth without using extra cement including mixing water proofing compound @ 2% by weight of cement. (b) Apply a coat of bituminous primer confirming to IS-3384@ 0.4 ltr/Sqm on newly plastered surface after curing as per IS-456 and dried. (c) After the primed surface has dried, apply a coat of hot blown bitumen(85/25 penetration) confirming to IS-702 @ 1.2 Kg/Sqm of the surface. (d) Provide polymeric water proofing membrane ISI marked laid with overlaps, bonded with hot blown bitumen, and laid by torch application method, end overlaps shall not be less than 150mm and side lap 75mm. Polymeric water proofing membrane should be five layered with centre core as 90 micron high molecular high density polyethylene film, min weight 3 Kg per sqm & minimum 3mm thick reinforced with polyster non wove fabric, APP membrane shall laid acorss the slop from lowest line of sloping roof towards ridge. (e) Over the APP membrane, apply a coat of semi hot blown 85/25 penetration grade bitumen confirming to IS-702 @ 1.20 Kg/ sqm and blinded with fine sand in dry condition @ 0.50 Kg / Sqm dusted over the bitumen coat Note : (i) Care shall be taken to avoid wrinkle and air gaps while sticking membrane to the bitumen applied surface. (ii) Ponding test shall be conducted for 72 hrs as directed. (iii) Rate of WPC included in the quoted rate.
Disconnecting existing tanks exc 500 ltr and n exc 1000 ltr, setting aside or lowering if required for repairs, cleaning, etc and hoisting if required reconnecting and re- fixing in position after cleaning and removing all scale and dirt etc from tanks and from mouths of circulating pipes etc, complete all as specified and directed.
Disconnecting existing tanks exc 1000 ltr and n exc 2000 ltr, setting aside or lowering if required for repairs, cleaning, etc and hoisting if required reconnecting and re- fixing in position after cleaning and removing all scale and dirt etc from tanks and from mouths of circulating pipes etc, complete all as specified and directed.
Taking up or down GI steel tubing 15/20/25mm bore and connections including cleaning for refixing or removal ,complete all as specifed and directed.
M&L for 15 mm bore galvanized iron GI tubing medium grade with all fittings such as bends, socket, tee, elbow, union, nipple, short pieces and fixed to walls, ceilings or laid in floors, complete all as specified and directed.
S&F for 20 mm bore galvanized iron GI tubing medium grade with all fittings such as bends, socket, tee, elbow, union, nipple, short pieces and fixed to walls, ceilings or laid in floors ,complete all as specified and directed.
Fixing only 15mm steel tubing and connection in new or old position(wall, ceiling, floors etc) complete all as specified and directed.
Fixing only 20mm steel tubing and connection in new or old position(wall, ceiling, floors etc) complete all as specified and directed.
S&F for rotational moulded polythylene water storage tank (ISI marked) with float valve, plastic lid cover, double layered, (cylindrical vertical with closed top), hoisted and fixed in position of capacity 500 ltrs including dismantling old unserviceable tank and making connections inlcuding suitable GI wash out, over flow pipe, nipple and including 20mm bore ball brass valve with union (two nos each) screwed for iron pipe and fixed in position, complete all as specifed in SSR Part-I and directed.
S&F for rotational moulded polythylene water storage tank (ISI marked) with float valve, plastic lid cover, double layered, (cylindrical vertical with closed top), hoisted and fixed in position of capacity 1000 ltrs including dismantling old unserviceable tank and making connections inlcuding suitable GI wash out, over flow pipe, nipple and including 20mm bore ball brass valve with union (two nos each) screwed for iron pipe and fixed in position ,complete all as specifed in SSR Part-I and directed.
S&F for 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints , fixed to wall with & including clams, nuts bolts complete ,after dismantling of old unserviceble PVC pipe, complete all as specified and directed.
S&F in repair for 110 mm bore PVC (SWR) bend any radius, complete all as specifed and directed by Engr-in-Charge.
M&L in repair for gun metal / glove or gate valves with iron wheel head screwed both end for iron pipes of 15 mm internal bore, complete all as specified and directed.
M&L in repair for gun metal / glove or gate valves with iron wheel head screwed both end for iron pipes of 20 mm internal bore, complete all as specified and directed.
M/S Jasbir Singh
vijay kumar
M/S Narinder Pal Choudhary
M/S Darshan Kumar
M/s Anil Engineers & Builders
RAJINDER CHOUDHARY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .