Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.2 LAccepted-AOC NOT AVAILABLE | L1 | Accepted-AOC Lowest bid | |
| 2 | L2₹34.5 L+₹75,325 (2.23%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹36.7 L+₹3.0 L (8.79%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹37.3 L+₹3.6 L (10.7%)Rejected-Finance | L4 | Rejected-Finance Other than L1 |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
3 Feb 2024, 6:00 pmClosed
GE (AF) Borjhar
Garrison Engineer (AF) Borjhar, Military Engineer Services, Guwahati Airport- PO, Borjhar Airport, Guwahati, Assam, Pin- 781015 Tele 0361 - 2840127
REPAIR COMPREHENSIVE MAINT OF MISC INTERNAL ELECTRIFICATION WKS ALONGWITH ATTENDING DAY TO DAY COMPLAIN AT 14 BRD AF AND 19 WING AF UNDER GE (AF) BORJHAR
2023_MES_633886_1
8390/BOR/E8
Open Tender
Civil Works
Item Rate
270 days
GE (AF) Borjhar
MES Contractor enlisted as Class D category b(i) having deposited Standing Security of Rs 100000.00 with dept. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category
7 documents required · 7 mandatory
₹500
GE (AF) Borjhar
₹70,000
Yes
8 Apr 2024
26 Dec 2023
5 Feb 2024
26 Dec 2023
3 Feb 2024
15 Jan 2024
Amount
Taking down carefully old point wiring (light, fan, socket, bell point or power point) complete including unserviceable fixtures like switches, sockets, holders, ceiling roses etc., removing from site and keeping in safe custody for taking credit and making good disturbed surfaces of wall/ceiling with cement plaster in cement mortar (1:6) and distempering/white washing to match the existing surface complete all as specified and as directed.
Taking down old fitting like FTL, PL, CFL, LED luminaires removing from site and keeping unserviceable fixtures etc, in safe custody for taking credit and making good distrubed surfaces of wall/ceiling with cement plaster in cement mortar (1:6) and distempering/white washing to match the existing surface, complete all as specified and as directed.
Taking down old fitting like FTL, PL, CFL, LED luminaires removing from site and keeping unserviceable fixtures etc, in safe custody, refixing it through screw or rawl plug etc., complete (after proper cleaning through mild cleaning agent) and making good disturbed surfaces of wall/ceiling with cement plaster in cement mortar (1:6) and distempering/white washing to match the existing surfaces, complete all as specified and as directed.
Taking down old unserviceable empty box /bus bar chamber/DB's of any capacity with MCCB's or MCB fixed on wall and making good disturbed surfaces of wall/floor with cement plaster in cement mortar (1:6) and distempering/white washing to match the existing surfaces, complete all as specified and as directed.
M & L for refixing of FTL, PL, CFL, LED luminaires (serviceable fixtures retrieved from item No.2) after cleaning the old luminaires by mild cleanser and making good disturbed surfaces of wall/ceiling with cement plaster in cement mortar (1:6) and distempering/white washing to match the existing surface, complete all as specified and as directed. Note: Replacement of connecting cable is deemed to be included in this rate.
M&L for point wiring with two single core PVC insulated unsheathed multistranded copper conductor cable (FRLSH) of size 1.5 Sqmm 1100 volts grade with one single core PVC insulated unsheathed multistranded copper cable (FRLSH) of size 1.5 Sqmm 1100 volts grade as earth conitnuity conductor (as per colour code), drawn through in and inlcuding PVC concealed conduit (medium graded) of size 25 mm with all accessories such as bend, elbow, tee etc and making grooves in any type of brick wall/ceiling, plastering and making good disturbed surfaces as per existing and connected to common earth dolly, sunk type metal box for housing/mounting the modular switch sockets with mounting plate/cover plate for One light point controlled by one no one way 6 Amps switch complete all as specified and directed.
All as per item No 6.00 here-in-before but for One fan point controlled by one no one way 6 Amps switch complete all as specified and directed
All as per item No 6.00 here-in-before but for One calling bell point controlled by one 5 Amps bell push switch complete all as specified and directed
All as per item No 6.00 here-in-before but for One 6 Amps socket outlet point on the same board with other switches complete all as specified and directed
All as per item No 6.00 here-in-before but for One 6 Amps switch socket complete combination point on independent board complete all as specified and directed
All as per Item No 6.00 here-in-before but with two single core PVC insulated unsheathed multistranded copper conductor cable (FRLSH) of size 2.5 Sq 1100 volts grade and one single core PVC insulated unsheathed ,multistranded copper conductor (FRLSH) of size 2.5 Sqmm 1100 volts grade as earth continuity conductor (as per colour code) including PVC concealed conduit (medium grade) of size 25 mm with all accessories such as bend, elbow, tee etc for 15 Amps switch socket combination point on independent board complete all as specified and directed
S&F modular switch single pole one way, 6 Amp, AC, 230 V all as specified and directed.
S&F modular bell push, 6 Amp, AC, 230 V all as specified and directed.
S&F modular switch single pole one way, 6 Amp, AC, 230 V all as specified and directed.
S&F modular socket 6A, AC, 230 V complete all as specified and directed.
S&F modular socket 6/16 Amp, AC, 230 V complete all as specified and directed.
S&F rotary step modular electronic fan regulator (2 module) flush type AC, 230 V complete all as specified and directed.
M&L for point wiring with two single core PVC insulated unsheathed multistranded copper conductor cable (FRLSH) of size 1.5 Sqmm 1100 volts grade with one single core PVC insulated unsheathed multistranded copper cable (FRLSH) of size 1.5 Sqmm 1100 volts grade as earth continuity conductor (as per colour code), drawn through in and inlcuding PVC casing caping of size 25mm, medium grade with all accessories such as bend, elbow, tee etc. in any type wall/ ceiling, plastering and making good disturbed surfaces as per existing and connected to common earth dolly, switch board or box plastic or PVC type for housing / mounting the switch sockets etc for One light point controlled by one no one way 6 Amps switch complete all as specified and directed.
All as per item No 18.00 here-in-before but for One fan point controlled by one no one way 6 Amps switch complete all as specified and directed
All as per item No 18.00 here-in-before but for One calling bell point controlled by one no 5 Amps bell push switch complete all as specified and directed
All as per item No 18.00 here-in-before but for One 6 Amps socket outlet point on the same board with other switches complete all as specified and directed
All as per item No 18.00 here-in-before but for One 6 Amps switch socket combination point on independent board complete all as specified and directed
All as per item No. 18 here-in-before but with two single core PVC insulated unsheathed multi stranded copper conductor cable (Heat Resistant Flame Retardant) of size 2.5 Sq 1100 volts grade and one single core PVC insulated unsheathed multistranded copper conductor (Heat Resistant Flame Retardant) of size 2.5 Sqmm 1100 Volts grade as earth continuity conductor (as per colour code) including PVC Casing Caping 25 mm dia for 15 Amps switch socket combination point on independent board complete all as specified and directed.
S&F ceiling Rose, surface, bakelite 65 x50 mm three terminals (ISI Marked), AC, 230 Volts complete all as specified & directed.
S&F switch piano flush type single pole one way (ISI Marked), 6 Amp, AC,230 V all as specified and directed.
S&F bell push flush type (ISI Marked), 6 Amp, AC,230 V all as specified and directed.
S&F socket outlet flush type 2 in 1, 6A, AC, 230V complete all as specified and directed.
S&F switch & socket combination flush type 2 in 1, 6A, AC, 230V complete all as specified and directed.
S&F switch socket combination flush type 2 in 1, 6 Pin, 20/10 Amp, AC, 230V with four fixing holes complete all as specified and directed.
S&F rotary step deluxe electronic fan regulator flush type 2 module, 100 W, 230 V AC complete all as specified and directed.
S&F Calling Bell Ding Dong Type AC, 230V complete all as specified and directed.
S&F Batten/Angle Lamp holder, PVC/ Polycarbonate type with back platefor fixing on the wall complete all as specified and directed. Make-Anchor (Code-39527/ 38538) / Havells Reo Note:- LED lamp will be issued under Schedule 'B' stores.
Supply and fixing light opal glass marble base with chrome finish luminaires with LED lamp 9W-E27 (R-G-B type) complete all as specified and directed.
S&F decorative, wall mounting, brushed nickel finish fixture with opal glass diffuser suitable for LED lamp 9W-B22 on the wall by stainless steel screw, rawl plug etc complete all as specified and directed. Make-Havells (Code LHFOAJE1TZ1I060 Note:- LED lamp will be issued under Schedule 'B' stores.
Supply of surface mounted batten type, slim LED luminaires 10 W, 220 - 240 V AC, 50 Hz, IP 20 with aluminium extruded housing, polycarbonate diffuser & end caps, minimum efficacy 100 lumens/watt with 120 degree viewing angle, CCT 6500, CRI ≥ 80, power factor ≥0.9, IP 20, surge protection 4.0 KV, THD < 20% integral electronic driver with short circuit protection and open circuit protection, surge voltage protection complete all as specified and directed.
Supply of surface mounted batten type, slim LED luminaires 20 W, 220 - 240 V AC, 50 Hz, IP 20 with aluminium extruded housing, polycarbonate diffuser & end caps, minimum efficacy 100 lumens/watt with 120 degree viewing angle, CCT 6500, CRI ≥ 80, power factor ≥0.9, IP 20, surge protection 4.0 KV, THD < 20% integral electronic driver with short circuit protection and open circuit protection, surge voltage protection complete all as specified and directed.
Fixing of surface mounted batten type LED luminaires (10 or 20 W, 230V AC) (as mentioned in sl 25 & 26) on the wall by stainless steel screw, rawl plug etc. & connecting up to ceiling rose with three core sheathed copper conductor cable (white/ gray colour) of suitable sizes complete incl taking down old unsv one all as specified and directed.
Supply of high efficacy recess mounted LED luminaires 36W, 240V AC, 2X2 tile in CRCA housing with full opal diffuser with flicker control technology to reduce harmful invisible flicker present in LED lighting sources, CCT 6500K, CRI ≥ 80, rated voltage 240V AC, power factor ≥0.95, IP 20, surge protection 2.5 KV, integral electronic driver with output short circuit protection and open circuit protection, surge voltage protection complete all as specified and directed.
Supply of Surface mounted LED luminaires 15 W, 220-240V AC, minimum size 300 mmX300 mm in diecast aluminium housing with PMMA diffuser, power factor ≥0.95, IP 20, surge protection 2.5 KV, integral electronic driver with output short circuit protection and open circuit protection, surge voltage protection complete all as specified and directed.
Supply of recess mounted LED luminaires 18 W, 220-240V AC, minimum size 295 mmX295 mm in diecast aluminium housing with PMMA diffuser, power factor ≥0.95, IP 20, surge protection 2.5 KV, integral electronic driver with output short circuit protection and open circuit protection, surge voltage protection complete all as specified and directed.
Supply of recess mounted LED luminaires 18 W, 220-240V AC, minimum size 206 mmX206 mm in diecast aluminium housing with PMMA diffuser, power factor ≥0.95, IP 20, surge protection 2.5 KV, integral electronic driver with output short circuit protection and open circuit protection, surge voltage protection complete all as specified and directed.
Supply of recess mounted LED luminaires 15 W, 220-240V AC, minimum size 180 mmX180 mm in diecast aluminium housing with PMMA diffuser, power factor ≥0.95, IP 20, surge protection 2.5 KV, integral electronic driver with output short circuit protection and open circuit protection, surge voltage protection complete all as specified and directed.
Supply of recess mounted LED luminaires 12 W, 220-240V AC, minimum size 160 mmX160 mm in diecast aluminium housing with PMMA diffuser, power factor ≥0.95, IP 20, surge protection 2.5 KV, integral electronic driver with output short circuit protection and open circuit protection, surge voltage protection complete all as specified and directed.
Supply of recess mounted LED luminaires 6 W, 220-240V AC, minimum size 107 mmX107 mm in diecast aluminium housing with PMMA diffuser, power factor ≥0.95, IP 20, surge protection 2.5 KV, integral electronic driver with output short circuit protection and open circuit protection, surge voltage protection complete all as specified and directed.
Supply of recess mounted LED luminaires 3 W, 220-240V AC, minimum size 72 mmX72 mm in diecast aluminium housing with PMMA diffuser, power factor ≥0.95, IP 20, surge protection 2.5 KV, integral electronic driver with output short circuit protection and open circuit protection, surge voltage protection complete all as specified and directed.
Supply of industrial bulkhead LED luminaires 10 W, 240V AC with aluminium die cast housing and vandal-resistant cover finished in epoxy powder-coated housing with diffuser, power factor ≥0.9, IP 65, surge protection 2.5 KV, integral electronic driver with output short circuit protection and open circuit protection, surge voltage protection complete all as specified and directed.
Fixing of recess or surface mounted type LED luminaires (3 to 36W, 230V AC) (as mentioned in sl 28 to 36) on the wall, roof, false ceiling by stainless steel screw, rawl plug etc. & connecting up to ceiling rose with three core sheathed copper conductor cable (white/ gray colour) of suitable sizes complete incl taking down old unsv one all as specified and directed.
M&L for painting with two coats of enamel paint over a coat of red oxide primer on steel surfaces of any description over 10cm in width or girth including preparation of old painted surfaces complete all as specified & directed.
M&L for writing letter, figures, arrows etc not exc 30 cm in height on Panel/ DB's or any other plant/ eqpt all as specified and directed.
M&L for sub main wiring with two run of single core PVC insulated unsheathed multi stranded copper conductor cable (FRLSH) of size 2.5 Sqmm 1100 volts grade and one run of PVC insulated unsheathed multistranded copper conductor cable (FRLSH) of size 2.5 Sqmm 1100 volts grade as earth continuity conductor (as per colour code) drawn through in and including DLP mini trunking of size 32X12.5mm with all finishing accessories and junction elements etc. in any type wall/ ceiling (fixing on wall through rawl plug & stainless steel screw) plastering and making good disturbed surfaces by cement mortar/ paint to match with the existing complete all as specified & directed.
M&L for sub main wiring with two run of single core PVC insulated unsheathed multi stranded copper conductor cable (FRLSH) of size 4.0 Sqmm 1100 volts grade and one run of PVC insulated unsheathed multistranded copper conductor cable (FRLSH) of size 4.0 Sqmm 1100 volts grade as earth continuity conductor (as per colour code) drawn through in and including DLP mini trunking of size 32X12.5mm with all finishing accessories and junction elements etc. in any type wall/ ceiling (fixing on wall through rawl plug & stainless steel screw) plastering and making good disturbed surfaces by cement mortar/ paint to match with the existing complete all as specified & directed.
M&L for sub main wiring with two run of single core PVC insulated unsheathed multi stranded copper conductor cable (FRLSH) of size 6.0 Sqmm 1100 volts grade and one run of PVC insulated unsheathed multistranded copper conductor cable (FRLSH) of size 6.0 Sqmm 1100 volts grade as earth continuity conductor (as per colour code) drawn through in and including DLP mini trunking of size 32X12.5mm with all finishing accessories and junction elements etc. in any type wall/ ceiling (fixing on wall through rawl plug & stainless steel screw) plastering and making good disturbed surfaces by cement mortar/ paint to match with the existing complete all as specified & directed.
M&L for sub main wiring with two run of single core PVC insulated unsheathed multi stranded copper conductor cable (FRLSH) of size 2.5 Sqmm 1100 volts grade and one run of PVC insulated unsheathed multistranded copper conductor cable (FRLSH) of size 2.5 Sqmm 1100 volts grade as earth continuity conductor (as per colour code) drawn through in and including PVC concealed conduit (medium grade) of size 25 mm with all accessories such as bend, elbow, tee etc and making grooves in any type of brick wall/ ceiling, plastering and making good disturbed surfaces as per existing and complete incl. taking down old one all as specified & directed.
M&L for sub main wiring with two run of single core PVC insulated unsheathed multi stranded copper conductor cable (FRLSH) of size 4.0 Sqmm 1100 volts grade and one run of PVC insulated unsheathed multistranded copper conductor cable (FRLSH) of size 4.0 Sqmm 1100 volts grade as earth continuity conductor (as per colour code) drawn through in and including PVC concealed conduit (medium grade) of size 25 mm with all accessories such as bend, elbow, tee etc and making grooves in any type of brick wall/ ceiling, plastering and making good disturbed surfaces as per existing and complete incl. taking down old one all as specified & directed.
M&L for sub main wiring with two run of single core PVC insulated unsheathed multi stranded copper conductor cable (FRLSH) of size 6.0 Sqmm 1100 volts grade and one run of PVC insulated unsheathed multistranded copper conductor cable (FRLSH) of size 6.0 Sqmm 1100 volts grade as earth continuity conductor (as per colour code) drawn through in and including PVC concealed conduit (medium grade) of size 25 mm with all accessories such as bend, elbow, tee etc and making grooves in any type of brick wall/ ceiling, plastering and making good disturbed surfaces as per existing and complete incl. taking down old one all as specified & directed.
S&F sheet metal enclosure for DB’s TPN Double Door 8 way, AC, 415 volt, IP 43 on the wall with MCCB, 160A, 4Pole of breaking capacity 16kA as incomer complete by masonry works/ cement plaster in cement mortar(1:6) & making good the disturbed surfaces and distempering /white washing to match the existing surface complete all as specified & directed.
S&F sheet metal enclosure for DB’s TPN Double Door 4 way, AC, 415 volt, IP 43 on the wall complete by masonry works/ cement plaster in cement mortar(1:6) & making good the disturbed surfaces and distempering /white washing to match the existing surface complete all as specified & directed.
S&F sheet metal enclosure for DB’s Vertical-TPN Double Door 12 way, AC, 415 volt, IP 43 on the wall with MCCB, 125 A, 4Pole of breaking capacity 25kA as incomer by masonry works/ cement plaster in cement mortar(1:6) & making good the disturbed surfaces and distempering /white washing to match the existing surface incl connection of cable, testing checking etc complete all as specified & directed. Note:- MCCB and MCB will be measured and paid separately.
S&F sheet metal enclosure for DB’s SPN Double Door 12 way, AC, 240 volt, IP 43 on the wall complete by masonry works/ cement plaster in cement mortar(1:6) & making good the disturbed surfaces and distempering /white washing to match the existing surface complete all as specified & directed.
S&F sheet metal enclosure for DB’s SPN Double Door 8 way, AC, 240 volt, IP 43 on the wall complete by masonry works/ cement plaster in cement mortar(1:6) & making good the disturbed surfaces and distempering /white washing to match the existing surface complete all as specified & directed.
S&F sheet metal enclosure for DB’s SPN Double Door 4 way, AC, 240 volt, IP 43 on the wall complete by masonry works/ cement plaster in cement mortar(1:6) & making good the disturbed surfaces and distempering /white washing to match the existing surface complete all as specified & directed.
S&F sheet metal enclosure for DB’s for Plug & Socket, SP, AC, 240 volt with MCB SP 16 A on the wall complete by cement plaster in cement mortar(1:6) & making good the disturbed surfaces and distempering /white washing to match the existing surface complete all as specified & directed.
S&F MCB TPN 40 to 63 Amps, 240 Volts 50 HZ, 10 KA breaking capacity complete all as specified & directed. Type ‘C’ Characteristic
S&F MCCB, 4P, 100 -125 Amps, 415 Volts 50 HZ, 36 KA, Ics= 50% Icu incl. connection of cable testing, checking etc complete all as specified & directed. Type ‘C’ Characteristic
S&F MCB SP 6 to 20 Amps, 240 Volts 50 HZ, 10 KA breaking capacity complete all as specified & directed. Type ‘C’ Characteristic
Refixing of MCB SP 6 to 20 Amps, 240 Volts 50 HZ, 10 KA breaking capacity complete all as specified & directed.
S&F MCB SPN 20 to 32 Amps 240 Volts, 50 Hz, 10 KA breaking capacity complete all as specified & directed.Type ‘C’ Characteristic
Supply only self adhesive PVC electrical insulation tape (1.8cmX6.5mX0.125mm) conforms to IS:7809 (Part-3).
Supply only piano switch 6 A, 240 V, 50 Hz, IP 20 one way conforms to IS: (Part- ).
Supply only rotary step deluxe electronic fan regulator flush type 2 module, 100 W, 230 V AC.
Supply only switch & socket combination flush type 2 in 1, 6A, AC, 230V complete all as specified and directed.
Supply only switch socket combination flush type 2 in 1, 6 Pin, 20/10 Amp, AC, 230V with four fixing holes complete all as specified and directed.
M&L for re-assembling or re-laying of existing sub main wiring of any cable type or sizes through in and including DLP U PVC trunking of 50X80 mm size incl. all finishing accessories such as angles, end caps, covers etc on roof /wall /ceiling etc complete and making good of wall/floor with cement plaster in cement mortar(1:6) and distempering /white washing to match the existing surface complete incl taking down old damage casing caping all as specified and directed by Engr-in-charge. Make-PVC Trunking- Legrand PVC Cable- Finolex/ Plaza/ Havells Note:- i) No PVC flexible conduit should be allowed in the wiring. ii) Any PVC cable required for re-assembling or re-laying of sumain wiring is deemed to be included in this rate, however in no more circumstances the length of cable of each size or type is not more than 5 RM iii) Items such as rawl plug, steel screw etc reqd for fixing DLP U PVC trunking is deemed to be included in this rate.
S&F ceiling Rose, surface, bakelite 65 x50 mm three terminals (ISI Marked), AC, 230 Volts on PVC box complete incl taking down old unsv/ broken one all as specified & directed.
M&L re-assembling or re-laying of wiring cable through in and including PVC casing caping of exising sizes and types incl. all finishing accessories on roof /wall /ceiling etc complete and making good of wall/floor with cement plaster in cement mortar(1:6) and distempering /white washing to match the existing surface complete incl taking down old damaged one all as specified and directed by Engr-in-charge. Note:- i) No PVC flexible conduit should be allowed in the wiring.
Material and labour for flame proof point wiring on wall and surface wiring on ceiling/ roof with necessary fixing arrangements for one light/fan point controlled by one switch with stranded PVC, FRLS insulated and unsheathed copper stranded conductor of size 1.5 sqmm, 1100 volts grade drawn in and including 14 gauge ERW rigid steel conduit (metallic) not less than 20 mm dia with all MS conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc., including PVC-FRLS insulated and unsheathed copper stranded conductor of size 1.5 sqmm, 1100 volts grade for continuous earthing complete all as directed.
All as per item No. 76 above but with 2.5 sq mm for one 15 Amps socket outlet on independent board and 2.5 sqmm PVC insulated multisranded copper conductor cable as continuous earth wire complete.
Supply and fix in repair flame proof rotary switch in ML6, 10/16 amps, single pole, 250 volts and enclosed cast aluminium body with threaded cover with switch operated by a sigle pole knob with double entries suitable for 20 mm dia ERW threaded steel conduit duly approved by CMRI dhanbad and as manufacturers intructions including taking down old flame proof rotary switch with enclosure complete all as directed.
Supply and fix in repair Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P+earth, 250 volts and enclosed cast aluminium body with threaded cover with switch operated by a sigle pole knob with double entries suitable for 20 mm dia ERW threaded steel conduit duly approved by CMRI dhanbad and as manufacturers intructions including taking down old flame proof rotary switch with enclosure complete all as directed.
Material and labour for sub main wiring on wall and surface wiring on ceiling/ roof with necessary fixing arrangements with two run of single core 4 sqmm multi stranded copper conductor, FRLS PVC insulated, unsheathed cable, including ERW rigid metallic steel conduit medium grade, ISI marked, 20 mm dia for sub main wiring including one run of single core 4 sqmm multi stranded copper conductor FRLS PVC insulated and unsheathed stranded copper conductor as earth wire in surface/ recess and fittings such as junction boxes, bends, tee, elbow etc., complete all as specified. (For light points)
M/s DC Traders
M/s B.M. Enterprise
M/s Rawat Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .