| 1 | L1₹17.3 LAccepted-AOC D 662 WZ 1598 R 1 NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹18.3 L+₹21.40 (<0.01%)Rejected-Finance 72 USMAN ENCAVE SECTOR O ALIGANJ LUCKNOW 226004 UP | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226004 | L2 | Rejected-Finance Being other than L1 | |
| 3 | L3₹18.6 L+₹36,602 (2.00%)Rejected-Finance | L3 | Rejected-Finance Being other than L1 | |
| 4 | L4₹20.2 L+₹2.0 L (10.8%)Rejected-Finance | L4 | Rejected-Finance Being other than L1 | |
| 5 | L5₹20.4 L+₹2.1 L (11.6%)Rejected-Finance | L5 | Rejected-Finance Being other than L1 |
Tender Value
₹23 L
EMD Value
₹46,000
Closing Date
9 Apr 2022, 6:00 pmClosed
GE EAST AGRA
GE East Agra, Military Engineer Services, Gwalior House, 62 Taj Road Agra Cantt 282001
REPAIR AND MAINTENANCE OF LT PANEL BOARD, LT CABLE AND MISC WORK WEST SIDE AREA UNDER GE(E) AGRA
2022_MES_512970_1
9434/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGRA
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE EAST AGRA
₹46,000
Yes
25 May 2022
10 Mar 2022
19 Apr 2022
10 Mar 2022
9 Apr 2022
24 Mar 2022
Amount
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out complete all as specified and directed.
All as per item No 1 here in before but depth exc 1.5 mtr but not exc 3.00 mtr
Returning filling, in including spreading ,leveling, watering and well ramming in layers not exc 25 cm each complete all as specified and directed.
Removing excavated material to a distance not exceeding 50 meters and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
M&L for sand cushioning to under ground cables 8 cm thick before laying the cable and 15 cm, thick after laying, stretching and testing the cable complete all as specified and directed.
M&L for Sub class ‘B’ bricks old size laid dry flat over the cable abutting each other, length of cable equal to width of brick complete all as specified and directed.
Laying only Sub class ‘B’ bricks old size retrieved against srl item 1 here in before laid dry flat over the cable abutting each other, length of cable equal to width of brick complete all as specified and directed.
M&L for cement concrete 1:4:8 type D2 ( using 40mm graded stone aggregate) for foundation of pole / stay including form work etc complete all as specified and directed.
M&L for cement concrete 1:3:6 type C1 ( using 20mm graded stone aggregate ) in coping of poles studs including form work etc complete all as specified and directed.
Taking out from trenches or wall/ pole or pipe cable LT 1100 volts grade heavy duty , armoured with steel strip of wire , with stranded aluminium conductor of any size upto 50 Sqmm , any core , for rectification of faults or replacement. Seggregating serviceable cable and unserviceable lenght by meggering or any other suitable and recommended method. Removing unserviceable from site and keeping aside serviceable for reuse at same location or any other location under AGE E/M all as rquired at site or directed. Note:-(Earth work will be measured and paid separately under respective item).
All as per Srl Item 10 here in above but of size 70 Sqmm to 240 Sqmm
Laying only in trenches or fixed to wall/pole or passing through pipe cable LT 1100 Volts grade heavy duty, armoured with aluminium conductor of any size upto 50 Sqmm any core. (Serviceable cables retrieved against srl item above will be used)
All as per Srl Item 12 here in above but of size 70 Sqmm to 240 Sqmm
Supply & laying in trenches or fixed to wall/pole or passing through pipe cable LT 1100 volts grade heavy duty,XLPE insulated , armoured heavy duty electric cable , with alumn conductor of any size 16 Sqmm 2 core complete all as specified and directed.
Supply & laying in trenches or fixed to wall/pole or passing through pipe cable LT 1100 volts grade heavy duty,XLPE insulated , armoured heavy duty electric cable , with alumn conductor of any size 25 Sqmm 3.5 core complete all as specified and directed.
Supply & laying in trenches or fixed to wall/pole or passing through pipe cable LT 1100 volts grade heavy duty,XLPE insulated , armoured heavy duty electric cable , with alumn conductor of any size 35 Sqmm 3.5 core complete all as specified and directed.
Supply & laying in trenches or fixed to wall/pole or passing through pipe cable LT 1100 volts grade heavy duty,XLPE insulated , armoured heavy duty electric cable , with alumn conductor of any size 50 Sqmm 3.5 core complete all as specified and directed.
Supply & laying in trenches or fixed to wall/pole or passing through pipe cable LT 1100 volts grade heavy duty,XLPE insulated , armoured heavy duty electric cable , with alumn conductor of any size 70 Sqmm 3.5 core complete all as specified and directed.
Supply & laying in trenches or fixed to wall/pole or passing through pipe cable LT 1100 volts grade heavy duty,XLPE insulated , armoured heavy duty electric cable , with alumn conductor of any size 95 Sqmm 3.5 core complete all as specified and directed.
Supply & laying in trenches or fixed to wall/pole or passing through pipe cable LT 1100 volts grade heavy duty,XLPE insulated , armoured heavy duty electric cable , with alumn conductor of any size 120 Sqmm 3.5 core complete all as specified and directed.
Supply & laying in trenches or fixed to wall/pole or passing through pipe cable LT 1100 volts grade heavy duty,XLPE insulated , armoured heavy duty electric cable , with alumn conductor of any size 185 Sqmm 3.5 core complete all as specified and directed.
Supply & laying in trenches or fixed to wall/pole or passing through pipe cable LT 1100 volts grade heavy duty,XLPE insulated , armoured heavy duty electric cable , with alumn conductor of any size 240 Sqmm 3.5 core complete all as specified and directed.
M&L for cable end termination kit in door/out door, heat shrinkable type suitable for XLPE/ PVC cables of size 25 Sqmm to 50 sqmm 3½ core core with working voltage 1100 volts complete all as specified and directed. make: Raychem/Denson/ M Seal
M&L for cable end termination kit in door/out door, heat shrinkable type suitable for XLPE/ PVC cables of size 70 Sqmm to 150 sqmm 3½ core core with working voltage 1100 volts complete all as specified and directed. make: Raychem/Denson/ M Seal.
M&L for cable end termination kit in door/out door, heat shrinkable type suitable for XLPE/ PVC cables of size 185 Sqmm to 300 sqmm 3½ core core with working voltage 1100 volts complete all as specified and directed. make: Raychem/Denson/ M Seal.
M&L for cable jointing kit straight through, heat shrinkable type suitable for XLPE/ PVC cables of size 25 Sqmm to 50 Sqmm3½ core core with working voltage 1100 volts complete all as specified and directed. make: Raychem/Denson/ M Seal.
M&L for cable jointing kit straight through, heat shrinkable type suitable for XLPE/ PVC cables of size 70 Sqmm to 150 Sqmm3½ core core with working voltage 1100 volts complete all as specified and directed. make:Raychem/Denson/ M Seal.
M&L for cable jointing kit straight through, heat shrinkable type suitable for XLPE/ PVC cables of size 185 Sqmm to 300 Sqmm3½ core core with working voltage 1100 volts complete all as specified and directed. make: Raychem/Denson/ M Seal.
Material and labour in replacement for GI tubing light grade 50mm bore with fittings laid for protection of cable under road crossing fixed to walls or pole complete all as specified and as directed.(clamps for fixing pipe, nuts, bolts washers shall be measured separately )
Taking down carefully ACSR conductor of any size from LT OH Lines after unbinding from insulators for replacement of multijointed / undersize conductors complete all as specified and directed.
M&L for ACSR conductor of any size drawn straight horizontal on over head lines on poles including binding with insulators using aluminium binding wire, jointing jumpers etc including connections of incoming and out going cables complete all as specified and directed.
Restringing and restretching aluminium conductor reterived under item srl 30 above including necessary binding with insulators using alunimium binding wire, connections of incoming and out going cables complete all as specified and directed.
Restretching aluminium conductor or GI wire on existing over head lines without removing including unbinding from insulator and rebinding to insulator using aluninium binding wire , connections of incoming and out going cables, binding with spacers where required, complete all as specified. (Note ;- For measurement length of each conductor shall be taken seperately.
M&L in replacement for GI wire 4mm dia drawn straight horizontal as continuous earth wire on poles or fabrication of cradles complete all as specified and directed.
M&L in replacement for aluminium strip of any size cut to length as required at site including drilling holes, bend to shape for repairing of LT panels/GOD'S complete all as specified and directed.
M&L in replacement for copper strip of any size cut to length as required at site including drilling holes, bend to shape for repairing of LT panel/ GOD switches complete all as specified and directed.
M&L in replacement for shackle type insulators of 100mm high, 115mm dia porcelain, vitreous, white, brown or green insulators for working pressure 1100 volts complete all as specified and directed.
M&L in replacement for pin insulators 75 mm height and 90mm dia size porcelain, vitreous, white, brown or green insulators for working pressure 1100 volts complete all as specified, required at site or directed.
M&L in replacement for stay assembly using GI stay rod 20mm dia complete with stay plate mild steel of size 300x300x6.00mm thick, stay bow complete all as specified and shown in Electrical Plate No 1 complete all as specified and directed. Note:-Necessary earth work, stay wire, loop insulator,clamps and PCC shall be measured and paid seperately.
M&L in replacement for Galvanised stay wire of size 7/4mm complete all as specified and directed.
M&L in replacement for loop type insulator large size porcelain vitirious of size 90 x 140 mm clearence of hole 16mm complete all as specified and directed.
M&L in replacement for steel tubular swaged pole 09 mtr long with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP 31, including painting with anti corrosive paint internally complete and externally up to planting depth, alternative black & white strips of 30 cm width upto 1.5 mtr above ground level, balance lenght to be painted with two coats of aluminium paint externally complete all as specified and directed. Note:- Necessary earth work, PCC will be measured and paid separately.
Supply and fixing in replacement MCCB having current ratings 63 Amps with rupturing cap 16 KA , AC 415 Volts 4 pole with thermal magnetic release complete with spreader links all as specified and directed including dismentling the existing U/S MCCBs with all connections complete all as specified and directed. Make Legrand/C&S/L&T/Siemens
Supply and fixing in replacement MCCB having current ratings 100 Amps with rupturing cap 16 KA , AC 415 Volts 4 pole with thermal magnetic release complete with spreader links all as specified and directed including dismentling the existing U/S MCCBs with all connections complete all as specified and directed. Make Legrand/C&S/L&T/Siemens
Supply and fixing in replacement MCCB having current ratings 160 Amps with rupturing cap 25 KA , AC 415 Volts 4 pole with microprocessor release complete with spreader links all as specified and directed including dismentling the existing U/S MCCBs with all connections complete all as specified and directed. Make Legrand/C&S/L&T/Siemens
Supply and fixing in replacement MCCB having current ratings 250 Amps with rupturing cap 36 KA , AC 415 Volts 4 pole with microprocessor release complete with spreader links all as specified and directed including dismentling the existing U/S MCCBs with all connections complete all as specified and directed. Make Legrand or equivalent of make /C&S/ABB/Siemens
Supply and fixing in replacement MCCB having current ratings 400 Amps with rupturing cap 36 KA , AC 415 Volts 4 pole with microprocessor release complete with spreader links all as specified and directed including dismentling the existing U/S MCCBs with all connections complete all as specified and directed. Make or equivalent of make Legrand /C&S/ABB/Siemens
Supply and fixing in replacement MCCB having current ratings 630 Amps with rupturing cap 50 KA , AC 415 Volts 4 pole with microprocessor release complete with spreader links all as specified and directed including dismentling the existing U/S MCCBs with all connections complete all as specified and directed. Make or equivalent of make Legrand /C&S/ABB/Siemens
Removing all connections from LT panel having feeders upto 04 Nos ( Total of incoming and outgoing) , any capacity, indoor or outdoor type, for repairs/ servicing. Cleaning properly all parts and removing dust, carbon deposits etc. Removing U/S thimbles if any of connections. Refixing serviceable items to the panel and making all connections including testing for proper functioning of the panel as per standard engineering pactice. ( U/S items will be provided against respective items separately.
Supply and fix in replacement epoxy based post insulators LT 440V for mounting bus bar complete all as specified and directed.
Scratching of old paint from the steel tubular pole 09 mtr height with out removing accessories and preparation of surfaces for repainting. Repainting the pole with one coat of alternative black and white strips of 30 cm each upto 1.5 mtr height using synthetic enamell paint . Marking the pole No with black enamell paint on yellow circle Repainting the remaining pole and iron parts i.e U clamps, chanels etc above 1.5 mtr height by applying one coat of alumn paint complete all as specified and directed.
Cutting/trimming the trees branches size n.exc. 100 mm dia at height of exc. 3 mtrs but not exc.12 mtrs crossing/ touching / embracing and around 1.50 m of the overhead lines of HT/LT thus of obstructing the uniform electric power supply including removing the same from site to a distance exceeding 50 mtrs complete all as specified and directed . Note: The measurement of running length shall be measured and paid as single for group of wires/lines.
Unnati Engineers
Balaji Associates
M/S RAJENDRA KUMAR AGARWAL
ASHOK INFRATECH
H.S.Kochhar n Sons
LUCKY SALES CORPORATION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .