Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.3 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹21.5 L+₹1.2 L (6.14%)Rejected-Finance 1ST FLOOR 100 FT ROAD NEAR HERO HONDA AGENCY OPP NARANG CHILDREN HOSPITAL BIBIWALA ROAD NORTH ESTATE | L2 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
Refer Docs
EMD Value
₹39,000
Closing Date
22 Feb 2021, 6:00 pmClosed
GARRISON ENGINEER
GARRISON ENGINEER (MES) DANAPUR CANTT
PROVN OF 02 X HIGH MAST LAMP AT MH SPL REPAIR REPLACEMENT OF BER REFRIGERATOR AND PROVN OF CERTAIN MINOR WORK IN AGE EM UNDER GE DANAPUR CANTT
2021_MES_415290_1
GE/DNR/T-62 OF 2020-21 / 8442/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
DANAPUR CANTT
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GARRISON ENGINEER
₹39,000
12 Mar 2021
22 Jan 2021
24 Feb 2021
22 Jan 2021
22 Feb 2021
5 Feb 2021
22 Jan 2021 - 4 Feb 2021
Amount
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cables & foundation of poles , stay assembly and getting out in any type of soil complete all as specified and directed.
Returning, filling in excavated approved soil, including spreading, leveling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed.
Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Supply and installation of Voltage stablizer for automatic operation, single phase naturally air cooled indoor type and dsigned for input variation between 90 Volts to 250 Volts with output Voltage Stablizer at 230 with of +- 2.5% and capacity of 5 KVA complete all as specified and as directed. Make: V-Gaurd /Blue Star/ Voltas.
Supply, installation and testing high wall split units indoor and outdoor complete unit with cordless remote control unit and with inbuilt air ioniser and plasma filter for better indoor air quality with PM 2.5 filter, BEE 5 Star rating and EER 3.2 of capacity 2.0 TR (Ton of refrigeration) including metal wall hunger of suitable size for fixing outdoor unit at wall complete all as specified and directed. Make:- Carrier, Model: DURAFRESH Nxi(5star) or equivalent model of Voltas/Blue Star/LG.
Supply and fixing socket outlet flush type 5 Amps, 5 pin, 230 Volts complete all as specified and as directed.
S&F single pole and neutral sheet metal enclosure with 2 pin and each plug and socket complete with one MCB SP 32 Amps 240 Volt complete all as specified and as directed.
Supply and fixing switch piano flush button single pole one way 5 amps, 230 Volts complete all as specified and as directed.
M & L for sub main wiring with two runs of single core multi stranded copper conductor cable of size 6 sqmm drawn through in and incl rigid PVC conduit and conduit accessories dia not less than 20 mm dia with 4 sqmm PVC insulated unsheathed single core copper conductor 1100 volts grade as earth continuity conductor complete all as specified & as directed. Note:- Two runs of 6 sqmm cable, one runs of 4 sqmm earth wire & one runs of PVC conduit shall be measured as one unit.
M & L for socket outlet 5 Amps point wiring with PVC insulated PVC unsheathed electric FRLS cable 1100V grade single core having multi stranded copper conductor of size 1.5 Sqmm nominal cross sectional area in & including non metallic rigid PVC conduit ISI marked medium grade not less than 20 mm dia with all conduit accessories in concealed wiring system by cutting of wall and making good disturbed surface of wall 1.5 sqmm green PVC insulated unsheathed copper conductor as a earth wire connected to earth dolly by providing lugs excluding MS boxes for mounting switches, sockets, fan regulators etc complete all as specified and as directed. Make of cable: Polycab/Havell's/Finolex and Make of PVC conduit: Plaza/Harsh/Kalinga Premium/AKG.
Supply and fixing of wall mounted fan 450 mm sweep, heavy duty, single phase, AC, 230 Volts, 50Hz, 3 star rating, ISI marked, jerk free oscillation, three speed control with pull cord switch including writing of MES Number 2.0 cm height with synthetic enamel paint and suitable size fan fixing bracket complete directions of Engr-in-Charge. Make : Bajaj/ Usha/ Crompton Greaves/Havells.
M & L dry sand cushioning to underground cables with 8cm thick before laying of cables and 15cm thick after laying and stretching of cable and gentally hand ramming and consolidation etc. complete all as specified and directed. Note :- Thickness of sand 18 cm thick shall be measured after punning of sand.e.
M & L for Old size sub class ‘B’ bricks, laid in trenches as cable protection covers complete all as specified and directed.
M & L for Cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and directed.
Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured LT electric power under ground cables, heavy duty with aluminium conductor of cross sectional area 25 sqmm 3.5 core with all fixing & connecting accessories such as Alluminium cable lugs, cable gland, nut, bolts, washer etc complete as specified and as directed. (Make: HAVELLS/ POLYCAB/Grandlay) (NOTE: Earthwork & Excavation, GI pipe brick protection etc shall be measured and paid separately under relevant items of this schedule 'A' part).
Supply, installation and commissioning of 12.5 Mtrs high mast system with its accessories. Mast shaft shall be in two sections,hot dip galvanised and suitable forwind velocity as per IS 875 and including head frame, steel wire rope 6 mm dia (7/19 construction), trailing cable, double drum winch, Galvanised Lantern carriage drum winch arrangement suitable for 6 (six) luminaires symmetrically and lightning finial. The mast shall have an integral power tool installed inside the base compartment for its operation with siutable size electric motor, foundation bolts manufactured from special steel along with nuts, washers, anchor plates and templates. The high mast lighting system supplied with the following accessories.Make : Bajaj/Crompton Greaves/Havells/Surya
(a) LED flood light luminaires 200 Watts IP 66 type with lens incl standard fittings pressure die cast aluminium housing with heat reistant toughened front glass housing with epoxy powder coated finsh and , complete with control gear box and all accessories duly prewired.- 06 Nos. Make: Bajaj/ Crompton Greaves/Havells/Surya
(b) Low intensity twin type aviation obstruction lamp of GLS type with super bright red LED 300 Nos per lamp of IP – 65 protection aviation obstruction light complete all as directed. Make – CG , Cat No – GLS – 704 – CDL / 60 OR equivalent Make to Havells / Bajaj / Surya .
(c) Supply, installation, testing and commissioning, factory made and tested, LT feeder pillar box ,outdoor type of size 900mm x 600mm x 500mm, platform mounted. The panel shall be dust and vermin proof, IP65 class protection and made out of 3.15mm thick CRCA MS sheet and 40x40x4mm thick angle iron frame work, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, front opening type, with aprons for cable entry, with double door shutter and locking arrangement including provn of 65mm Godrej (Freedom) stranded lock with 2 keys, internal wiring with PVC insulated, stranded copper conductor FRLS cable, IS-694 marked of adequate size but not less than 10 Sqmm. The following items accommodated with this feeder pillar including 02 Nos danger notice plate made of 1.6mm thick mild steel sheet, vitreous enameled white of size 25 x 20cm with letter figures and conventional skull bones in signal red colour and fixed nuts, bolts and washers etc with voltage and danger indicated in Hindi and English complete all as specified and directed. The scope of work includes the following items accommodate the same panel.
(d) (i) Stag type, 4 way terminal (I/P) 63 Amps – 01 No (PCB 150 ACBC) (ii) MCCB 4 Pole, 415 volts AC grade, 40 Amps 25 KA Icu=100%Ics.(Make: Legrand/L&T/ SIEMENS) - 01 No (iii) Contactor 3 pole 32 Amps – 01 No (Legrand/L&T/SIEMENS) (iv) Toggle switch 6 Amps – 01 No (v) Timer (analogue) with battery backup – 01 No (Legrand/L&T/SIEMENS) (vi) Stage type, 4 way terminal (O/P) 63 Amps-01 No (PCB 150 ACBC) (vii) Over load relay 2/3.5A – 01 No (Legrand/L&T/SIEMENS) (viii) F. contractor 9 A – 01 No (Legrand/L&T/SIEMENS) (ix) R. contractor 9A – 01 No (Legrand/L&T/SIEMENS) (x) Motor terminal 32 Amps – 01 No (Legrand/L&T/HPL) (xi) Push switch terminal (STD) – 01 No (Legrand/L&T/SIEMENS) (xii) Push switch (F/R) (STD) – 01 No (Legrand/L&T/SIEMENS)
(d) Pole drawing and RCC/PCC foundation work for errection of pole shall be carried out as per manufacturers approved drawings.
(e) PCC foundation work for LT control Panel as per manufacturers approved drawings.
(f) Work to be executed by the manufacturer or there authhorized rep and MOU undertaking of the same from the manufacturer be submitted prior to excution of work .
Supply and fixing of GI tubing, light grade, 40 mm bore with all fitting laid in trenches / pole / wall for protection of cables in repairs complete.
M & L for Earthing to OH/Sub stn with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to main earth lead 32 x 6 mm galvanised iron strip dia by means of bolts, nut, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.5 of MES Schedule pt-I 1991, GI earth strip 32 x 6 mm protected by GI pipe 15mm dia light grade and connected to earth test point including excavation in any type of soil,returning filling, disposal of soil, providing charcoal dust and common salt upto top edge of earth plate, construction of PCC pit with RCC cover, funnel, watering pipe of 20mm dia GI light grade and provision of earth test point including testing on completion complete all as specified and directed.
Supply, installation and testing of Refrigerator, electric driven single phase 240 volts 50 Hz, single door capacity 195 Ltrs storage volume capacity BEE 5 star rated, frost free, auto defrost to stop ice-buildup, Inverter Compressor, energy efficient, less noise & more durable, toughened glass inner self with all accessories complete all as specified and directed. Make: Samsung/LG/Whirlpool.
Supply, installation and testing of Refrigerator, electric driven single phase 240 volts 50 Hz, single door capacity 210 Ltrs storage volume capacity BEE 5 star rated, frost free, auto defrost to stop ice-buildup, Inverter Compressor, energy efficient, less noise & more durable, toughened glass inner self with all accessories complete all as specified and directed. Make: Samsung/LG/Whirlpool.
M/S Priya Trading Agency
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .